HomeMy WebLinkAbout252 Normandy Ln; ; CBRA2017-0016; PermitPrint Date: 10/22/2019
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
252 Normandy Ln
BLDG-Associated Permit Resi
2030230400
$323,847.62
1
3.00
RANCHO PARADISO
Permit
Work Class:
Lot#:
Reference #:
Construction Type:
Single Family Detached
DEV16022
Bathrooms: 2.00
Orig. Plan Check#: PC2016-0041
Plan Check#:
(city of
Carlsbad
Permit No: CBRA2017-0016
Status:
Applied:
Issued:
Permit
Fina led:
Closed -Finaled
01/19/2017
04/03/2018
Inspector: TFraz
Final
Inspection: 10/22/2019 4:59:14Pr
Description: BARBERIO: 1982 SF PRIMARY DU// 516 SF GARAGE// 688 SF DECK (2DU ON CBRA2017-0017)
Applicant:
KIRK MOELLER ARCHITECTS INC
KIRK MOELLER
760-803-8006
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
DRAINAGE FEE PLDA A Medium Runoff
Owner:
COOWNER BARBERIO GARY T&SANDRA
4270 Clearview Dr
CARLSBAD, CA 92008
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PUBLIC FACILITIES FEES -outside CFO
SB1473 GREEN BUILDING STATE STANDARDS FEE
SDCWA SYSTEM CAPACITY CHARGE S/8" Displacement
SEWER CONNECTION FEE (General Capacity all areas)
STRONG MOTION-RESIDENTIAL
SW PPP INSPECTION FEE TIER 1-Medium BLDG
SWPPP PLAN REVIEW FEE TIER 1-MEDIUM
TRAFFIC IMPACT Residential Single Fam. Outside CFO
TRAFFIC IMPACT Residential Single Fam. Outside CFO
WATER METER FEE 1" Displacement
WATER SERVICE CONNECTION FEE 5/8" DISPLACEMENT (P)
WATER TREATMENT CAPACITY CHARGE 5/8" Displacement
Total Fees: $33,052.66 Total Payments To Date: $29,232.66
$1,421.20
$994.84
$648.85
$66.00
$166.00
$92.00
$182.00
$11,334.67
$13.00
$5,099.00
$934.00
$42.10
$232.00
$55.00
$3,820.00
$3,290.00
$352.00
$4,169.00
$141.00
Balance Due: $3,820.00
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
·----"" --------·-----+--
_ ~,;" , ,, PERMIT INSPECTION HISTORY REPORT (CBRA2017-0016)
Permit Type: BLDG-Associated Permit Residential Application Date: 01/19/2017 Owner:
Work Class: Single Family Detached Issue Date: 04/03/2018 Subdivision:
Status: Closed -Finaled Expiration Date: 11/18/2019 Address:
IVR Number: 1510
Scheduled Actual Date Start Date Inspection Type Inspection No, Inspection Status Primary Inspector
1012912018 1012912018 BLDG-17 Interior
Lath/Drywall
074267-2018
Checklist Item
BLDG-Building Deficiency
0212712019 02127/2019 BLDG-21 084777-2019
Underground/U nderf
loor Plumbing
BLDG-Electric Meter 084776-2019
Release
03/1912019 03119/2019 BLDG-21 086523-2019
Underground/Underf
loor Plumbing
Checklist Item
BLDG-Building Deficiency
0410812019 04108/2019 BLDG-Fire Final 088336-2019
0411712019 04117/2019 BLDG-Final
Inspection
October 22, 2019
Checklist Item
FIRE-Building Final
089129-2019
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
Passed Andy Krogh
COMMENTS
lath showers & tubs
Passed Andy Krogh
Passed Andy Krogh
Cancelled Andy Krogh
COMMENTS
Passed Cindy Wong
COMMENTS
Partial Pass Andy Krogh
COMMENTS
Green and waste received, requires
engineering signature, T-24 paperwork
COOWNER BARBERIO GARY
T&SANDRA
GRANVILLE PK
252 Normandy Ln
Carlsbad, CA 92008
Reinspection Complete
Complete
Passed
Yes
Complete
Complete
Reinspection Complete
Passed
No
Complete
Passed
Yes
Reinspection Incomplete
Passed
No
Yes
Yes
Yes
Yes
Page 3 of 3
,,, . ..PERMIT INSPECTION H1~1ORY REPORT (CBRA2017-0016) ' '
Permit Type: BLDG-Associated Permit Residential Application Date: 01/19/2017 Owner:
Work Class: Single Family Detached Issue Date: 04/03/2018 Subdivision:
Status: Closed -Finaled Expiration Date: 11/18/2019 Address:
IVR Number: 1510
Scheduled
Date
Actual Start Date Inspection Type Inspection No.
Checklist Item
BLDG-Building Deficiency
BLDG-15 067051-2018
Roof/ReRoof (Patio)
09/0512018 09/05/2018 BLDG-13 Shear
Panels/HO (ok to
wrap)
069065-2018
09/07/2018 0910712018 BLDG-16 lnsulalion 069356-2018
Checklist Item
BLDG-Building Deficiency
BLDG-34 Rough
Electrical
069355-2018
Checklist Item
BLDG-Building Deficiency
0912112018 09/2112018 BLDG-84 Rough 070659-2018
Combo(14,24,34,44)
Checklist Item
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
1010212018 1010212018 BLDG-16 lnsulatlon 071720-2018
1011012018 1011012018 BLDG-17 Interior
Lath/Drywall
072423-2018
Checklist Item
BLDG-Building Deficiency
BLDG-18 Exterior 072424-2018
Lath/Drywall
Checklist Item
BLDG-Building Deficiency
October 22, 2019
Inspection Status Primary Inspector
COMMENTS
Deck sheeting
Passed Andy Krogh
Passed Andy Krogh
Partial Pass Tim Frazee
COMMENTS
Insulation of soffit at garage OK, framing of
both sides interior of garage and soffit at
apartment back door
Partial Pass Tim Frazee
COMMENTS
Rough electrical at garage and apartment
back for soffits OK
Passed Tim Frazee
COMMENTS
Passed Andy Krogh
Partial Pass Tim Frazee
COMMENTS
Interior drywall done, need to lath showers
& tubs
Partial Pass T1m Frazee
COMMENTS
Drywall OK, showers and tubs need to be
lathed, Exterior lath Ok except the
expansion joints need alterations, see card
--·--~---·
COOWNER BARBERIO GARY
T&SANDRA
GRANVILLE PK
252 Normandy Ln
Carlsbad, CA 92008
Reinspection
Passed
Yes
Re inspection
Passed
Yes
Reinspectlon
Passed
Yes
Passed
Yes
Yes
Yes
Yes
Yes
Reinspection
Passed
Yes
Re\nspection
Passed
Yes
Complete
Complete
Complete
Incomplete
Incomplete
Complete
Complete
Incomplete
Incomplete
Page 2 of 3
PERMIT INSPECTION HISTORY REPORT (CBRA2017-0016)
Permit Type: BLDG-Associated Permit Residential Application Date: 01/19/2017 Owner:
Work Class: Single Family Detached Issue Date: 04/03/2018 Subdivision:
Status: Closed -Finaled Expiration Date: 11/18/2019 Address:
IVR Number: 1510
Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector
10/22/2019 BLDG-Final 108496-2019
Inspection
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
04/0412018 04/04/2018 BLDG-SW-Pre-Con 053846-2018
Checklist Item
BLDG-Building Deficiency
04/1812018 04/18/2018 BLDG-11 055357-2018
Foun dation/Ftg/Pler
s (Rebar)
Checklist Item
BLOG-Building Deficiency
BLDG-12 Steel/Bond 055358-2018
Beam
Checklist Item
BLDG-Building Deficiency
05/0112018 05/0112018 BLDG-21 056591-2018
Underground/U nderf
loor Plumbing
05/0712018 05/07/2018 BLDG-66 Grout 057206-2018
Checklist Item
BLDG-Building Deficiency
05/10/2018 05/10/2018 BLDG-11 057675-2018
Foundatlon/Ftg/Pier
s (Rebar)
Checklist Item
BLDG-Building Deficiency
06/14/2018 06/14/2018 BLDG-14 061093-2018
Frame/Steel/Bolting/
Welding (Decks)
Checklist Item
BLDG-Building Deficiency
08/1512018 08115/2018 BLDG-14 067050-2018
Frame/Steel/Bolting/
Weldlng (Decks)
October 22, 2019
Passed Paul Burnette
COMMENTS
Green and waste received, requires
engineering signature, T-24 paperwork
Passed Andy Krogh
COMMENTS
Meet with contractor and homeowner
Passed
COMMENTS
Passed
COMMENTS
Passed
Partial Pass
COMMENTS
Tim Frazee
Tim Frazee
Andy Krogh
Andy Krogh
CMU block wall first lift
Partial Pass Andy Krogh
COMMENTS
All but garage SOG
Partial Pass Paul Burnette
COMMENTS
Partial Pass Andy Krogh
•-~-•-f-----.
COOWNER BARBERIO GARY
T&SANDRA
GRANVILLE PK
252 Normandy Ln
Carlsbad, CA 92008
Reinspection
Passed
No
Yes
Yes
Yes
Yes
Passed
Yes
Passed
Yes
Passed
Yes
Re inspection
Passed
Yes
Reinspection
Passed
No
Reinspection
Passed
No
Reinspection
Complete
Complete
Complete
Complete
Complete
Complete
Incomplete
Incomplete
Incomplete
Incomplete
Page 1 of 3
PIOJB:T:
ADDRESS :
ADCRESS:
TIM::IN:
M/1.'IERIAL:
A e ilr!i lU J T ' iii 1 ,jr t 1M ~~~. -' -:,' AF'F'CJR.OAB LE INSPECTIONS
0 SIBEL A.5SEM3LY/WELDING
0 EIDXY AN:;l{)RS/COIEIS
0 SHEAR WALL FRAMIN3 SYSTEM
BUG PER1IT:
CW',JER:
ARCHITECT:
il-GINEER:
<XNI'AAC'IOR:
SVOCCNI'RAC'IOR :
760-846-1464
PO Box 900864
San Diego,CA 92190
www.AccuTechSD.com
JBietz@AccuTechSD.com
□ DATE : o&-le>-□ TESTING/SAMPLING
□ OlliER:
SPEJ::IAL INSPECTICN IXlES NOT RELIEVE THE avNER, (X)NIRlCI'CR CR BUIIIER OF THEIR RESPCNSIBILITY TO PERFORM ALL WffiK PER THE
APPROVED PIANS, SPECIFICATIONS AND APPLICABIE BUIIDING CDDE. EOR ANY N:N--<DNEOFMING I'IEM3 PIEA5E SCHEDUIE EOR RE-
INSPECTICN. ALL W:>RK EERFORMID IS BIIJ.ED IN 4 HJUR It-,CREMENI'S ACCDRDING 'IO OOR ClJRRENl' RATE SOlEIXJLE.
I .AGREE 'IO INID1NIFY AND IDLD HA™I.ESS THE INSPEJ::'IOR AND ACilJ'IE::H AflORmBIE INSPECTICNS EOR ANY AND ALL DAMI\CES WHE'IllER
Aa.:IIE-JThL OR INTENTIONZIL . I WILL PKI EOR ANY AND ALL AT'IORNEY AND CXXJRI' CXBTS. I WILL PKI EOR ANY AND ALL JUJil.flJTS
BPCVGHT AGAINST THE INSPEC'IOR AND/OR Aa.:UI'ECH AFFOODABLE INSPECTICNS DUE 'IO ANY'IHIN3 RELATED TO THIS PROJECT.
CWNER: r:.\'IE:
<XNI'AAC'IOR:
PROJECT NAME Rancho Paradiso
ADDRESS 252 Normandy Ln.
Carlsbad, Ca.
ARCHITECT
ENGINEER
CONTRACTOR
OTHER
MAA
R2H Engineering
Diversified Const.
INSPECTION REPORT
INSPECTION
0 CONCRETE
0 REINF. STEEL
□
□
□
MASONRY
P.T. CONCRETE
FIELD WELDING
MATERIAL IDENTIFICATION
CONG. MIX NO. & lb/in2
GROUT MIX NO. & lb/in2
MORTAR TYPE & lb/in2
REINF. STEEL GR./SIZE
STRUCTURAL STEEL
0 SHOP WELDING HIGH-STRENGTH BOLT
INSPECTION DATE o9-o4-2o2a ------------0 BATCH PLANT MASONRY BLOCK
PLAN FILE/OTHER 0 EXP. ANCHOR OTHER
BLDG. PERMIT/OTHER CBRA2017-001 6 OTHER Shear walls
MATERIAL SAMPLING
□ CONCRETE □ MORTAR □ GROUT □ FIREPROOFING □ MASONRY BLOCK
□ REINFORCING STEEL □ STRUCTURAL STEEL □ BOLTS O OTHER
INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS
PLEASE NOTE ANY RE-INSPECTION, TESTING, OR OTHER PROJECT ISSUES.
I visually inspected the shear walls that require special inspection as noted below.
Locations: at Level 1; (2) SW-3 along 3 line. (1) 15'2" and (1) 3'0" SW-2 along 1 line. At Level 2; (1) 12'6" SW-2 along C line from 2.5 to 4
and (1) 4'6" along 4 line.
Sheathing: 3/8" category 1, span rating 24/0 OSB.
Nails: 2-3/4 x.132" (8d common) collated gun nails, 4" o.c. E.N.&B.N. Galvanized nails at the pressure treated sill plates.
Note: The following components were checked; framing members for size and grade, shear wall lengths per plan call outs, hold down
sizes and fastening, anchor bolts, nailing for size, spacing, edge distances and flush with the surface, A35's/LTP4's for spacing and
fastening. CS14 at openings nailed to 4x blocking. MSTC straps connecting Level 1 to Level 2 at hold down posts.
ALL COMPONENTS OF THE SHEAR WALL MEET OR EXCEED PLAN CALLOUTS AND CBC.
No discrepancies were observed or noted.
All work is subject to City of Carlsbad approval.
Certification of Compliance: All work, unless otherwise noted, complies with applicable codes and the approved plans and specifications.
PRINTED NAME Craig Bechtel ---------------
CERTIFICATION NO. ICC 5265295 SD-1024 SIGNATURE _~ &Ju ____ _
Baker Land Surveys, Inc.
4213 Sunnyhill Drive
Carlsbad, CA. 92008
(760) 729-6676 bakerlandsurveys@gmail.com
Building Lines Certification Letter
Date: April 30, 2018
From: John Douglas Baker
To: City of Carlsbad Engineering and Building Department
Subject: Building Lines certification for the construction of the Barbario residence
located at 226 Normandy Lane, Carlsbad, CA. City of Carlsbad Building Permit #s
CBRA2017-0016 and CBRA2017-0018.
This letter is to inform you that I, John Douglas Baker, Licensed Surveyor 6287,
performed a field survey on 3/26/18 to provide Steady Builders Inc. with building
line/elevation stakes per said approved plans. A survey was performed to establish
property lines and elevations. Said construction staking was in relation to the survey.
I returned to said site on 4/30/18 to check the footing forms. Forms were found to be set
per building line/elevation stakes.