Loading...
HomeMy WebLinkAbout252 Normandy Ln; ; CBRA2017-0016; PermitPrint Date: 10/22/2019 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 252 Normandy Ln BLDG-Associated Permit Resi 2030230400 $323,847.62 1 3.00 RANCHO PARADISO Permit Work Class: Lot#: Reference #: Construction Type: Single Family Detached DEV16022 Bathrooms: 2.00 Orig. Plan Check#: PC2016-0041 Plan Check#: (city of Carlsbad Permit No: CBRA2017-0016 Status: Applied: Issued: Permit Fina led: Closed -Finaled 01/19/2017 04/03/2018 Inspector: TFraz Final Inspection: 10/22/2019 4:59:14Pr Description: BARBERIO: 1982 SF PRIMARY DU// 516 SF GARAGE// 688 SF DECK (2DU ON CBRA2017-0017) Applicant: KIRK MOELLER ARCHITECTS INC KIRK MOELLER 760-803-8006 BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) DRAINAGE FEE PLDA A Medium Runoff Owner: COOWNER BARBERIO GARY T&SANDRA 4270 Clearview Dr CARLSBAD, CA 92008 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -outside CFO SB1473 GREEN BUILDING STATE STANDARDS FEE SDCWA SYSTEM CAPACITY CHARGE S/8" Displacement SEWER CONNECTION FEE (General Capacity all areas) STRONG MOTION-RESIDENTIAL SW PPP INSPECTION FEE TIER 1-Medium BLDG SWPPP PLAN REVIEW FEE TIER 1-MEDIUM TRAFFIC IMPACT Residential Single Fam. Outside CFO TRAFFIC IMPACT Residential Single Fam. Outside CFO WATER METER FEE 1" Displacement WATER SERVICE CONNECTION FEE 5/8" DISPLACEMENT (P) WATER TREATMENT CAPACITY CHARGE 5/8" Displacement Total Fees: $33,052.66 Total Payments To Date: $29,232.66 $1,421.20 $994.84 $648.85 $66.00 $166.00 $92.00 $182.00 $11,334.67 $13.00 $5,099.00 $934.00 $42.10 $232.00 $55.00 $3,820.00 $3,290.00 $352.00 $4,169.00 $141.00 Balance Due: $3,820.00 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov ·----"" --------·-----+-- _ ~,;" , ,, PERMIT INSPECTION HISTORY REPORT (CBRA2017-0016) Permit Type: BLDG-Associated Permit Residential Application Date: 01/19/2017 Owner: Work Class: Single Family Detached Issue Date: 04/03/2018 Subdivision: Status: Closed -Finaled Expiration Date: 11/18/2019 Address: IVR Number: 1510 Scheduled Actual Date Start Date Inspection Type Inspection No, Inspection Status Primary Inspector 1012912018 1012912018 BLDG-17 Interior Lath/Drywall 074267-2018 Checklist Item BLDG-Building Deficiency 0212712019 02127/2019 BLDG-21 084777-2019 Underground/U nderf loor Plumbing BLDG-Electric Meter 084776-2019 Release 03/1912019 03119/2019 BLDG-21 086523-2019 Underground/Underf loor Plumbing Checklist Item BLDG-Building Deficiency 0410812019 04108/2019 BLDG-Fire Final 088336-2019 0411712019 04117/2019 BLDG-Final Inspection October 22, 2019 Checklist Item FIRE-Building Final 089129-2019 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Passed Andy Krogh COMMENTS lath showers & tubs Passed Andy Krogh Passed Andy Krogh Cancelled Andy Krogh COMMENTS Passed Cindy Wong COMMENTS Partial Pass Andy Krogh COMMENTS Green and waste received, requires engineering signature, T-24 paperwork COOWNER BARBERIO GARY T&SANDRA GRANVILLE PK 252 Normandy Ln Carlsbad, CA 92008 Reinspection Complete Complete Passed Yes Complete Complete Reinspection Complete Passed No Complete Passed Yes Reinspection Incomplete Passed No Yes Yes Yes Yes Page 3 of 3 ,,, . ..PERMIT INSPECTION H1~1ORY REPORT (CBRA2017-0016) ' ' Permit Type: BLDG-Associated Permit Residential Application Date: 01/19/2017 Owner: Work Class: Single Family Detached Issue Date: 04/03/2018 Subdivision: Status: Closed -Finaled Expiration Date: 11/18/2019 Address: IVR Number: 1510 Scheduled Date Actual Start Date Inspection Type Inspection No. Checklist Item BLDG-Building Deficiency BLDG-15 067051-2018 Roof/ReRoof (Patio) 09/0512018 09/05/2018 BLDG-13 Shear Panels/HO (ok to wrap) 069065-2018 09/07/2018 0910712018 BLDG-16 lnsulalion 069356-2018 Checklist Item BLDG-Building Deficiency BLDG-34 Rough Electrical 069355-2018 Checklist Item BLDG-Building Deficiency 0912112018 09/2112018 BLDG-84 Rough 070659-2018 Combo(14,24,34,44) Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers 1010212018 1010212018 BLDG-16 lnsulatlon 071720-2018 1011012018 1011012018 BLDG-17 Interior Lath/Drywall 072423-2018 Checklist Item BLDG-Building Deficiency BLDG-18 Exterior 072424-2018 Lath/Drywall Checklist Item BLDG-Building Deficiency October 22, 2019 Inspection Status Primary Inspector COMMENTS Deck sheeting Passed Andy Krogh Passed Andy Krogh Partial Pass Tim Frazee COMMENTS Insulation of soffit at garage OK, framing of both sides interior of garage and soffit at apartment back door Partial Pass Tim Frazee COMMENTS Rough electrical at garage and apartment back for soffits OK Passed Tim Frazee COMMENTS Passed Andy Krogh Partial Pass Tim Frazee COMMENTS Interior drywall done, need to lath showers & tubs Partial Pass T1m Frazee COMMENTS Drywall OK, showers and tubs need to be lathed, Exterior lath Ok except the expansion joints need alterations, see card --·--~---· COOWNER BARBERIO GARY T&SANDRA GRANVILLE PK 252 Normandy Ln Carlsbad, CA 92008 Reinspection Passed Yes Re inspection Passed Yes Reinspectlon Passed Yes Passed Yes Yes Yes Yes Yes Reinspection Passed Yes Re\nspection Passed Yes Complete Complete Complete Incomplete Incomplete Complete Complete Incomplete Incomplete Page 2 of 3 PERMIT INSPECTION HISTORY REPORT (CBRA2017-0016) Permit Type: BLDG-Associated Permit Residential Application Date: 01/19/2017 Owner: Work Class: Single Family Detached Issue Date: 04/03/2018 Subdivision: Status: Closed -Finaled Expiration Date: 11/18/2019 Address: IVR Number: 1510 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector 10/22/2019 BLDG-Final 108496-2019 Inspection Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final 04/0412018 04/04/2018 BLDG-SW-Pre-Con 053846-2018 Checklist Item BLDG-Building Deficiency 04/1812018 04/18/2018 BLDG-11 055357-2018 Foun dation/Ftg/Pler s (Rebar) Checklist Item BLOG-Building Deficiency BLDG-12 Steel/Bond 055358-2018 Beam Checklist Item BLDG-Building Deficiency 05/0112018 05/0112018 BLDG-21 056591-2018 Underground/U nderf loor Plumbing 05/0712018 05/07/2018 BLDG-66 Grout 057206-2018 Checklist Item BLDG-Building Deficiency 05/10/2018 05/10/2018 BLDG-11 057675-2018 Foundatlon/Ftg/Pier s (Rebar) Checklist Item BLDG-Building Deficiency 06/14/2018 06/14/2018 BLDG-14 061093-2018 Frame/Steel/Bolting/ Welding (Decks) Checklist Item BLDG-Building Deficiency 08/1512018 08115/2018 BLDG-14 067050-2018 Frame/Steel/Bolting/ Weldlng (Decks) October 22, 2019 Passed Paul Burnette COMMENTS Green and waste received, requires engineering signature, T-24 paperwork Passed Andy Krogh COMMENTS Meet with contractor and homeowner Passed COMMENTS Passed COMMENTS Passed Partial Pass COMMENTS Tim Frazee Tim Frazee Andy Krogh Andy Krogh CMU block wall first lift Partial Pass Andy Krogh COMMENTS All but garage SOG Partial Pass Paul Burnette COMMENTS Partial Pass Andy Krogh •-~-•-f-----. COOWNER BARBERIO GARY T&SANDRA GRANVILLE PK 252 Normandy Ln Carlsbad, CA 92008 Reinspection Passed No Yes Yes Yes Yes Passed Yes Passed Yes Passed Yes Re inspection Passed Yes Reinspection Passed No Reinspection Passed No Reinspection Complete Complete Complete Complete Complete Complete Incomplete Incomplete Incomplete Incomplete Page 1 of 3 PIOJB:T: ADDRESS : ADCRESS: TIM::IN: M/1.'IERIAL: A e ilr!i lU J T ' iii 1 ,jr t 1M ~~~. -' -:,' AF'F'CJR.OAB LE INSPECTIONS 0 SIBEL A.5SEM3LY/WELDING 0 EIDXY AN:;l{)RS/COIEIS 0 SHEAR WALL FRAMIN3 SYSTEM BUG PER1IT: CW',JER: ARCHITECT: il-GINEER: <XNI'AAC'IOR: SVOCCNI'RAC'IOR : 760-846-1464 PO Box 900864 San Diego,CA 92190 www.AccuTechSD.com JBietz@AccuTechSD.com □ DATE : o&-le>-□ TESTING/SAMPLING □ OlliER: SPEJ::IAL INSPECTICN IXlES NOT RELIEVE THE avNER, (X)NIRlCI'CR CR BUIIIER OF THEIR RESPCNSIBILITY TO PERFORM ALL WffiK PER THE APPROVED PIANS, SPECIFICATIONS AND APPLICABIE BUIIDING CDDE. EOR ANY N:N--<DNEOFMING I'IEM3 PIEA5E SCHEDUIE EOR RE- INSPECTICN. ALL W:>RK EERFORMID IS BIIJ.ED IN 4 HJUR It-,CREMENI'S ACCDRDING 'IO OOR ClJRRENl' RATE SOlEIXJLE. I .AGREE 'IO INID1NIFY AND IDLD HA™I.ESS THE INSPEJ::'IOR AND ACilJ'IE::H AflORmBIE INSPECTICNS EOR ANY AND ALL DAMI\CES WHE'IllER Aa.:IIE-JThL OR INTENTIONZIL . I WILL PKI EOR ANY AND ALL AT'IORNEY AND CXXJRI' CXBTS. I WILL PKI EOR ANY AND ALL JUJil.flJTS BPCVGHT AGAINST THE INSPEC'IOR AND/OR Aa.:UI'ECH AFFOODABLE INSPECTICNS DUE 'IO ANY'IHIN3 RELATED TO THIS PROJECT. CWNER: r:.\'IE: <XNI'AAC'IOR: PROJECT NAME Rancho Paradiso ADDRESS 252 Normandy Ln. Carlsbad, Ca. ARCHITECT ENGINEER CONTRACTOR OTHER MAA R2H Engineering Diversified Const. INSPECTION REPORT INSPECTION 0 CONCRETE 0 REINF. STEEL □ □ □ MASONRY P.T. CONCRETE FIELD WELDING MATERIAL IDENTIFICATION CONG. MIX NO. & lb/in2 GROUT MIX NO. & lb/in2 MORTAR TYPE & lb/in2 REINF. STEEL GR./SIZE STRUCTURAL STEEL 0 SHOP WELDING HIGH-STRENGTH BOLT INSPECTION DATE o9-o4-2o2a ------------0 BATCH PLANT MASONRY BLOCK PLAN FILE/OTHER 0 EXP. ANCHOR OTHER BLDG. PERMIT/OTHER CBRA2017-001 6 OTHER Shear walls MATERIAL SAMPLING □ CONCRETE □ MORTAR □ GROUT □ FIREPROOFING □ MASONRY BLOCK □ REINFORCING STEEL □ STRUCTURAL STEEL □ BOLTS O OTHER INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS PLEASE NOTE ANY RE-INSPECTION, TESTING, OR OTHER PROJECT ISSUES. I visually inspected the shear walls that require special inspection as noted below. Locations: at Level 1; (2) SW-3 along 3 line. (1) 15'2" and (1) 3'0" SW-2 along 1 line. At Level 2; (1) 12'6" SW-2 along C line from 2.5 to 4 and (1) 4'6" along 4 line. Sheathing: 3/8" category 1, span rating 24/0 OSB. Nails: 2-3/4 x.132" (8d common) collated gun nails, 4" o.c. E.N.&B.N. Galvanized nails at the pressure treated sill plates. Note: The following components were checked; framing members for size and grade, shear wall lengths per plan call outs, hold down sizes and fastening, anchor bolts, nailing for size, spacing, edge distances and flush with the surface, A35's/LTP4's for spacing and fastening. CS14 at openings nailed to 4x blocking. MSTC straps connecting Level 1 to Level 2 at hold down posts. ALL COMPONENTS OF THE SHEAR WALL MEET OR EXCEED PLAN CALLOUTS AND CBC. No discrepancies were observed or noted. All work is subject to City of Carlsbad approval. Certification of Compliance: All work, unless otherwise noted, complies with applicable codes and the approved plans and specifications. PRINTED NAME Craig Bechtel --------------- CERTIFICATION NO. ICC 5265295 SD-1024 SIGNATURE _~ &Ju ____ _ Baker Land Surveys, Inc. 4213 Sunnyhill Drive Carlsbad, CA. 92008 (760) 729-6676 bakerlandsurveys@gmail.com Building Lines Certification Letter Date: April 30, 2018 From: John Douglas Baker To: City of Carlsbad Engineering and Building Department Subject: Building Lines certification for the construction of the Barbario residence located at 226 Normandy Lane, Carlsbad, CA. City of Carlsbad Building Permit #s CBRA2017-0016 and CBRA2017-0018. This letter is to inform you that I, John Douglas Baker, Licensed Surveyor 6287, performed a field survey on 3/26/18 to provide Steady Builders Inc. with building line/elevation stakes per said approved plans. A survey was performed to establish property lines and elevations. Said construction staking was in relation to the survey. I returned to said site on 4/30/18 to check the footing forms. Forms were found to be set per building line/elevation stakes.