Loading...
HomeMy WebLinkAbout2521 PALOMAR AIRPORT RD; 103; CB131520; Permit08-02-2013 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB131520 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 2521 PALOMAR AIRPORT RD CBADSt 103 Tl Sub Type COMM 2130201800 Lot# 0 $58,615 00 Construction Type 5B Reference # CRAZY BOWLS & WRAPS- 1003 SF SHELL TO RESTAURANT Status Applied Entered By Plan Approved Issued Inspect Area Plan Check # ISSUED 06/21/2013 RMA 08/02/2013 08/02/2013 Applicant VIKING COMMERCIAL CONSTRUCTION ATTN TODD KUHLMAN 1825 ASTON AV CARLSBAD CA 92008 760 277-3582 Owner COUNTY OF SAN DIEGO PUBLIC AGENCY OOOOO Building Permit $494 72 Meter Size Add'l Building Permit Fee $0 00 Add'l Red Water Con Fee $0 00 Plan Check $346 30 Meter Fee $0 00 Add'l Building Permit Fee $0 00 SDCWA Fee $0 00 Plan Check Discount $0 00 CFD Payoff Fee $0 00 Strong Motion Fee $12 31 PFF (3105540) $1,066 79 Park Fee $0 00 PFF (4305540) $984 73 LFM Fee $0 00 License Tax (3104193) $0 00 Bndge Fee $0 00 License Tax (4304193) $0 00 BTD #2 Fee $0 00 Traffic Impact Fee (3105541) $0 00 BTD #3 Fee $0 00 Traffic Impact Fee (4305541) $0 00 Renewal Fee $0 00 PLUMBING TOTAL $186 00 Add'l Renewal Fee $0 00 ELECTRICAL TOTAL $133 00 Other Building Fee $0 00 MECHANICAL TOTAL $74 17 Pot Water Con Fee $0 00 Master Drainage Fee $0 00 Meter Size Sewer Fee $0 00 Add'l Pot Water Con Fee $0 00 Redev Parking Fee $0 00 Red Water Con Fee $0 00 Additional Fees $0 00 Green Bldg Stands (SB1473) Fee $1 00 HMP Fee 99 Fire Expedidted Plan Review $317 50 Green Bldg Standards Plan Chk 99 TOTAL PERMIT FEES $3,616 52 Total Fees $3,616 52 Total Payments To Date $3,616 52 Balance Due: $0 00 Inspector FINAL Date APPROVAL Clearance NOTICE Please take NOTICE that approval of your project includes the 'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this pemiit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your nght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously othenvise expired THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE EIlPLANNING nENGlNEERING nBUILDING OFIRE nHEALTH •HAZMAT/APCD CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave , Carlsbad, CA 92008 Ph 760-602-2719 Fax 760-602-8558 email building@carlsbadca gov www carlsbadca gov jl Plan Check No. /J / ^^jQ Est. Value Plan Ck Deposi^ Date Qx\ i 13 SWPPP JOB ADDRESS 2521 Palomar Airport Road SUITE#/SPACE#/UNIT# 103 213 020 18 00 CT/PROJECT # # OF UNITS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME Crazy Bowls & Wraps CONSTR TYPE V-B B DESCRIPTION OF WORK (nc/ude Square Feet of Affected Area(s> A 1,003sf tenant Improvement withm an existmg one story retail shell for a small restaurant of less than 50 occupants. Improvements include a new kitchen, single toilet, sales area, seating, mechanical, electrical and plumbing EXISTING USE Shell PROPOSED USE restaurant GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE YESr~|# NOfTI AIR CONDITIONING YESrTlNol I FIRE SPRINKLERS YESlTlNOi I APPLICANT NAME (Primary Contact) Todd Kuhlman APPLICANT NAME (Secondary Contact; ADDRESS 1825 Aston Ave ADDRESS CITY Carlsbad STATE CA ZIP 92008 CITY STATE ZIP PHONE 760/277-3582 760/931-9955 PHONE FAX EMAIL tkuhlman@vikingcc.com EMAIL PROPERTY OWNER NAME Keith Kitsis CONTRACTOR BUS NAME Vikinq Commercial Construction ADDRESS 286 East Ave ADDRESS 1825 Aston Ave CITY St. Louis STATE MO ZIP 63119 CITY Carlsbad STATE CA 92008 PHONE 314-503-4660 FAX 314-918-0518 PHONE 760-931-9990 FAX 760-931-9955 EMAIL kkitsis@crazybowlsandwraps.com EMAIL info@vikingcc.com ARCH/DESIGNER NAME & ADDRESS Warren Scott Architects STATE Lie # C-001211 804831 CITY BUS UC# 1221095 (Sec 70315 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions ofthe Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 ofthe Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)) Workers' Compensation Declaraton / hereby affirm under per)alty of perjury one ofthe following declarations S I have and will maintain a certificate of consent to self insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the woh< for which this permit is issued I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this pemiit is issued My workers' compensation insurance camer and policy number are InsuranceCo. state fund Policy No , 90505922013 Expiration Date _ This section need not be completed if the permit is for one hundred dollare ($100) or less I I Certficate of Exemption I certify that in the perfomiance of the worl< for which this perniit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensabon, damages as provided for in Secbon 3706 of the Labor code, interest and attomey's fees s t vgS" CONTRACTOR SIGNATURTy ^^J^**** ^ [7] AGENT DATE "7/ 3 ( / I ^ / hereby affirm that I am exempt from Contractor's License Law for the following reason I I I, as owner of the property or my employees with wages as their sole compensation, will do the work and the stmcture is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such wori( himself or through his own employees, provided that such improvements are not intended or offered for sale If, however the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) I I I, as owner of the property am exclusively contracting with licensed contractors to constnict the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) I I I am exempt under Section _ .Business and Professions Code for this reason 1 I personally plan to provide the major labor and matenals for construction of the proposed property improvement QYes I INO 2 I (have / have not) signed an application for a building pemiit for the proposed work 3 I have contracted with the following pereon (fimi) to provide the proposed constmction (include name address / phone / contractore' license number) 4 I plan to provide portions of the work, but I have hired the following person to coonlinate, supervise and provide the major work (include name / address / phone / contractore' hcense number) 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the wort( indicated (include name / address / phone / type of vrori() jS^PROPERVt OWNER SIGNATURE QAGENT DATE Is the applicant or future building occupant required to submit a business plan, xutely hazardous matenals registration form or nsk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account AcP Yes No Is the applicant or future building occupant required to obtain a pemiit from the air pollution control distnct or air quality management district' Yes No Is the facility to be constmcted within 1,000 feet of the outer boundary of a school site'' Yes No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there is a construction lending agency for the performance of the work this pennit is issued (Sec 3097 (i) Civil Code) Lender's Name Lender's Address I cerbly that I have read the applicaton and state that the above i I hereby authonze representative of the City of Cartsbad to a AGAINST ALL LIABILmES, JUDGMBffSrCO^rS OSHA An OSHA pemnit is requiredwexcavatioimovef 5'j)' c| EXPIRATION Every pemnit issusS by the Building affdalllid 180 days from the date of such ^rmit or if the buildirij \r vWik yefAPPLICANT'S SIGNATURE iton IS conect and that the infoimaton on the plans is accuiate I agree to comply with all City oidinances and State laws relatng to building constucbon ,4xin Ihe above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD ' S WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSECUENCE OF THE GRANTING OF THIS PERMIT ajid jtemoliton or constaiction of stractures over 3 stones in height isons of this (Me shall expire by limitaton and become null and void if the building or work authonzed by such pemnit is not commenced within by such pemiit is suspended or abandoned at any time after the vioik is commenced for a penod of 180 days (Section 106 4 4 Unifomn Building Code) DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. CERTIFICATE OF OCCUPANCV (Commerc ial Projects Only) Fax (760) 602-8560, Email buildinq(S)carlsbadca gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008 C0#. (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE CITY STATE ZIP Carlsbad CA PHONE FAX EMAIL OCCUPANTS BUS LIC No DELIVERY OPTIONS PICK UP CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg 1) MAILTO CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg 1) IVIAIL/FAX TO OTHER ASSOCIATED CB#- NO CHANGE IN USE / NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION >ef APPLICANT'S SIGNATURE DATE Inspection List Permit# CB131520 Type Tl COMM Date 09/19/2013 09/19/2013 09/12/2013 09/12/2013 09/05/2013 09/04/2013 08/28/2013 08/23/2013 08/19/2013 08/16/2013 08/08/2013 08/07/2013 08/05/2013 Inspection Item 89 Final Combo Final Combo Final Combo Final Combo T-Bar Gas/Test/Repairs Rough/Ducts/Dampers Sew/er/Water Service Rough Combo Rough Combo Rough Electric Ftg/Foundation/Piers Underground/Under Floor Inspector PD PD PD PD PD PB PD PD PD PD PD Act Rl AP Rl PA AP AP AP AP AP CO PA NR AP CRAZY BOWLS & WRAPS- 1003 SF SHELL TO RESTAURANT Comments AM PLS - COF FIRE IN AM Friday, September 20, 2013 Page 1 of 1 4iniHJ*i>ii jjflUi^t.iH'l*- I • Ptkr* -T"-* *i"''*T| ni •^•f • <f -t^ i ^^''^'Sfi. 'n! li,,, 3ow..iiiiifi l^}>\.\,r» 1.1 Kft ..IJ 1 > .1,'rL,. .i!fr.M i^«^A>Jt «Ot.j_di*i* ^/'k .ll,,'', .i-O,^, 7- • Requtrcd Prior to Rccjwcrt• • • r, i'l-.i.i- « n.< .! s --' Planning, L»ndsc.«pe , CM& iglnspeettonij Fire Pre wrrtlon' Type of Siiio.Tste:' - UK0AT1ON TijH' ot !i.*p£ 'tior- SNFORCEB STEEI >SONBVt>HbCaOUT SfiSUT OWAaORAlNS rMSELS r«|eww8'iASS^.:..fyl o*{>FSHa™rNr. r('liSilIii^wiM£: •;• WATgi'HEATg" SOlAJtWATeS .' fOLW^ili^^ —- lii\pfrior '#3*1 -I D.IK ilFC'P.iCtI |.^;c^c V'J'LTAIC •f3y .iri'.L 2tili»£i— '/J.-i-iLti iiisiiliii- - . U I 'lOlitOilPi.M) L.LCT'-I'IP.S "Vl ' auci'il'^l^lt)^• fi-i"" M3 , KEAT-Alft_COM> SYS'.. ^.S i.4'J FINAL ,!.)/ iiRuv-v i.Lxr^^ASiiili1i;i^ §ipcciu._ I :::!?_!}j}^^!9^^^^'lz:i:Jil .{.SJ t:jJ f- i • ' . . >^¥'^'iiwip«!0'i»»iB n us.'i A'SOv'lllliC ,D'. ' ! ^SOVIUHLJ.IIHYI-BOMAIIC T i S KI'.AL ! f.ARUL'GH lf' • .'• I * L nxin IXTIV.UI5 lii'Jf! i-vsrE^Siccii FtXEO |«fp Will'S«W^!'RH& ".MCPieAtfpsliRK-,',. '-^^miiiii ^agnnfersH jircliitecU BflSS Ridgeha/L-n Courj Suile 200 S5S 573.6898 fax WW w tifc n^iwar re n, to fti Doug Moody Esgil Corporation RE Crazy Bowls and Wraps- Palomar Commons, Carlsbad - Plan Check Number PC 13- 1520 We are the structural engineers for the shell building at 2521 Palomar Airport Road, currently under construction with Building Permit number CB120788 Crazy Bowls and Wraps IS the tenant for Suite 103 and is requesting structural confirmation that the existing roof structure can accommodate the loading ofthe proposed HVAC units These units are within the original design load Based on the shell calculations, the existing roof structure can accommodate the HVAC unit loads without modification to the framing Thank You, Glenn Mouritzen SE, LEED AP Pnncipal Todd Kuhlman From* Kevin Drum [kdrum@drumplumbing com] Sent Saturday, July 13, 2013 9 09 AM To- Warren Scott, Todd Kuhlman Subject. RE CBW CARLSBAD Attachments: CBW-Carlsbad-Plumbing_7-15-13_P30_PC pdf, CBW-Carlsbad-Plumbing_7-15-13_P10 _PC pdf, CBW-Carlsbad-Plumbing_7-15-13_P20_PC pdf Please see attached plan check corrected drawings P-10 has fire department notes clouded and denoted delta-1 # 8 Esgil plan check correction has been cleared by Glen Adamick (Doug Moody was on vacation Friday) Glen said he would talk to him upon his return The code requirement he is quoting is overruled by county health (floor sink required and indirect waste required for 3-comp sink) Please let me know if you have any questions, thanks Kevin Drum Drum Plumbing, Inc President (760) 598-3786 ext 101 (760) 598-3780 Fax kdrum(S)drumplumbing com www drumplumbing com "Quality and Value By Design" Note The information contained in this transmission is privileged, confidential and intended soley for the addressed recipient If you are not the intended recipient, then you are hereby notified that any reading, dissemination, distribution or copying of this communication is strictly prohibited by law If you have received this communication in error then please notify our office using the phone number or addrss above and then destroy this document immediately From: Warren Scott [mailto"wscott@wsaaia.com] Sent: Friday, July 12, 2013 12:18 AM To: Todd Kuhlman', Kevin Drum Subject: CBW CARLSBAD Kevin, Todd, Just to make sure you have the Fire department correction list that required a couple of notes on the Plumbing drawings for resubmittal see attached Thanks, Warren City of Carlsbad Permit No. f Address Valuation Worksheet Assessor Parcel No. Date Building Division By •i Type^of Work [ Area of Work Multiplier VALUE ' - ; SFD and Duplexes $110 17 $0 00 Residential Additions $13173 $0 00 Remodels / Lofts $57 48 $0 00 Apartments & Multi-family $98 20 $0 00 Garages/Sunrooms/Solariums $28 74 $0 00 Patio/Porch/Carport $9 58 $0 00 Enclosed Patio $15 51 $0 00 Decks/Balconies/Stairs $15 57 $0 00 Retaining Walls, concrete,masonry $19 16 $0 00 Pools/Spas-Gunite $40 72 $0 00 Tl/Stores, Offices $37 12 $0 00 Tl/Medical, restaurant, H occupancies 1,003 $50 30 $50,450 90 Photovoltaic Systems/ # of panels $400 00 $0 00 $0 00 $0 00 $0 00 $0 00 $0 00 $0 00 $0 00 $0 00 Fire Sprinkler System 1,003 $3 11 $3,119 33 Air Conditioning - commercial 1,003 $5 03 $5,045 09 Air Conditioning - residential $4 19 $0 00 Fireplace/ concrete, masonry $3,855 98 $0 00 Fireplace/ prefabricated Metal $2,62134 $0 00 $0 00 $0 00 TOTAL Valuation: $58,615 Comm/Res (C/R): C Building Fee $494 72 Plan Check Fee $346 30 Strong Motion Fee $12 00 Green Bldg Stand Fee $1 00 Green Bldg PC Fee $0 00 License Tax/PFF $2,051 54 License Tax/PFF (in CFD) $1,066 80 CFD 1st hour of Plan CheckFire Expedite Plumbing Mechanical Electncal TBD TBD TBD $58,615 32 CFD 0 Yes (PFF= =1 82%) 0 No (PFF = 3.5%) Land Use. Density Improve Area Fiscal Year Annex Year Factor. CREDITS PFF and/orCFD Explanation: EsGil Corporation In (Partners Ht-p witH government for (BuiCding Safety DATE 7/25/13 • APPLICANT ia<JURIS JURISDICTION City of Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO 13-1520 SET II PROJECT ADDRESS 2521 Palomar Airport Rd Suite 103 PROJECT NAME Crazy Bowls 8s Wraps - TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes ^ The plans transmitted herewith will substantially comply with the junsdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck I I The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the junsdiction to forward to the applicant contact person I I The applicant's copy of the check list has been sent to IXI EsGll Corporation staff did not advise the applicant that the plan check has been completed I I EsGll Corporation staff did advise the applicant that^the plan check has been completed Person contacted Telephone # Date contacted (by ) Email Fax # Mail Telephone Fax In Person XI REMARKS The person responsible for the preparation of the plans must sign all sheets By Doug Moody Enclosures EsGll Corporation • GA • EJ • PG 7/18/13 9320 Chesapeake Dnve, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In (Partnership wttH government for (Building Safety DATE 7/5/13 • ABPU&Am "JURIS, JURISDICTION City of Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO 13-1520 SET I PROJECTADDRESS 2521 Palomar Airport Rd Suite 103 PROJECT NAME Crazy Bowls 8s Wraps - TI I I The plans transmitted herewith have been corrected where necessary and substantially comply With the junsdiction's codes I I The plans transmitted herewith will substantially comply with the junsdiction's codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck X The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the junsdiction to forward to the applicant contact person X The applicant's copy of the check list has been sent to Viking Construction / Todd Kuhlman 1825 Aston Ave, Carlsbad CA 92008 I I EsGll Corporation staff did not advise the applicant that the plan check has been completed I I EsGll Corporation staff did advise the applicant that the plan check has been completed Person contacted Todd Kuhlman (S-H) Telephone # 760-277-3582 Date contacted '7lsli3(by ^ ) Email tkuhlman@vikingcc com Fax # 760-931-9955 1^Mail ^ TelephoneFax In Person • REMARKS By Doug Moody Enclosures EsGll Corporation • GA • EJ • PC 6/25/13 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 7/5/13 13-1520 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO 13-1520 JURISDICTION City of Carlsbad OCCUPANCY B USE Restaurant TYPE OF CONSTRUCTION VB ACTUAL AREA 986sf ALLOWABLE FLOOR AREA STORIES 1 HEIGHT SPRINKLERS'? Yes OCCUPANT LOAD 28 REMARKS DATE PLANS RECEIVED BY JURISDICTION 6/21/13 DATE PLANS RECEIVED BY ESGIL CORPORATION 6/25/13 DATE INITIAL PLAN REVIEW COMPLETED 7/5/13 PLAN REVIEWER Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electncal Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineenng Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 2010 CBC, which adopts the 2009 IBC The following items listed need clanfication, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 105 4 of the 2009 International Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when vou submit the revised plans. City of Carlsbad 13-1520 7/5/13 Please make all corrections on the ongmal tracings, as requested in the correction list Submit three sets of plans for commercial/industnal projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineenng and Fire Departments 2 Bnng one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineenng and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineenng and Fire Departments until review by EsGll Corporation is complete 1 Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes Business and Professions Code 2 Provide evidence of Health Department approval (for restaurants), where regulated by the local Health Department 3 Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support of the 705# rooftop air handler unit Include all calculations and finding on the plans Please include the California license number, seal, date of license expiration and date plans are signed Business and Professions Code 4 Provide a section view of the new soffits and floating clouds Show a) Type, size and spacing of studs Indicate gauge for metal studs Specify manufacturer and approval number or indicate "to be ICBO approved" b) Method of attaching top to the structure and lateral bracing c) Please provide details specific to the floating suspended ceiling assemblies d) Show height of the soffit from floor, soffit to roof framing or floor framing 5 Please have the document author and the pnnciple designer ofthe LTG-1 C form sign the impnnted document 6 Please complete the LTG-1-C part 3 of 4 mandatory automatic controls portion ofthe LTG-1-C forms to show the occupancy sensors 7 Please correct the lighting plans to be consistent with the LTG forms and show a 250 watt current limiter as shown on the LTG -1C part 2 of 4 form Please provide the required LTG-5C form City of Carlsbad 13-1520 7/5/13 8 Show the required floor drains in the following locations, as per UPC Section 411 2 a) Commercial kitchens UPC Section 4112 2 and in accordance with section 704 3 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly descnbe them and where they are located in the plans Have changes been made to the plans not resulting from this correction lisf? Please indicate Yes • No • The junsdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you City of Carlsbad 13-1520 7/5/13 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PLAN CHECK NO 13-1520 PREPARED BY Doug Moody DATE 7/5/13 BUILDING ADDRESS 2521 Palomar Airport Rd Suite 103 BUILDING OCCUPANCY B TYPE OF CONSTRUCTION VB BUILDING PORTION AREA ( Sq Ft) Valuation Multiplier Reg Mod VALUE ($) Tl /0a3>- 986' 50 30 49,596 (^ fl^PftJ^ Air Conditioning Fire Spnnklers TOTAL VALUE Junsdction Code cb By Ordinance Bldg Permit Fee by Ordinanoe • $450 62 Plan Check Fee by Ordinance Type of Review QRepetitve Fee ~ Repeats Complete Review • Other j—j Hourly EsGil Fee • Structural Only Hr @ $292.90 $252 35 Comments Sheet 1 of 1 macvalue doc + PLAN CHECK PLAN CHECK Community & Economic * « \/ ^ CITY OF A Df CP* A PI REVIEW Development Department 1635 Faraday Avenue * « \/ ^ CITY OF A Df CP* A PI TRANSMITTAL Carlsbad CA 92008 www carlsbadca gov DATE: 6/28/13 PROJECTNAME:Crazy Bowls & Wraps PROJECT ID: SDP 09-05 PLAN CHECK NO:CB131520 SET#:I ADDRESS: 2521 Palomar Airport #103 APN:213-020-1% VALUATION: $50,451 APPLICANT CONTACT: tkuhlman(a)vikingcc.com X This plan check review transmittal is to notify you of clearance by: LAND DEVELOPMENT ENGINEERING DIVISION Final Inspection by the Construction & Inspection Division is required: Yes L J Wo |X! For status from a division not marked below, please call 760-602-2719 This plan check review is NOT COIVIPLETE. Itenis missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. 1 LAND DEvkORilNT ENG. * I- ..v\ 760;€IO^-275'0'%.^ ..:T*lEIREPR'EVEiTION '''^l1*y-^^"t%^'^**t*''•• ^ 760-802-4624 r Chtis Sexton@car!3badca gov j r i Kathleen Lawrence [ L ! 760-602-2741 j Kathleen Lawrence@carlsbadca gov ^ ""i Greg Ryan Gregory Ryan@carlsbadca gov j j 1 Gina Ruiz 760-602-4675 » Gma Ruiz@ca}l«5bacica gov j \/ Linda Ontiveros /\ 760-602-2773 t Lmda Ontiveros@carlsbadca gov | 1 j . Cindy Wong j —~ 760-602-4662 | Cynthia Wong®carlsbadca gov 1 f "* 1 1 f"^] Don 1! Fieri L _j 760-602-4664 Dommic Fieri(*carlsbadca gov I Remarks Engineering impact fees paid under CB 120788 V CITY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK REVIEW CHECKLIST P-28 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www carlsbadca eov DATE: 7-19-13 PROJECT NAME: PROJECTID: PLAN CHECK NO: CB 13-1520 SET#: 1 ADDRESS: 2521 Palomar Airport Rd APN: 213-020-18-00 ^ This plan check review is complete and has been APPROVED by the Planning Division. By: Chris Sexton A Final Inspection by the Planning Division is required • Yes ^ No Vou may also have corrections from one or more of ttie divisions listed below. Approval from tiiese divisions may be required prior to ttie issuance of a building permit. Resubmitted plans sliould include corrections from all divisions. I I This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: tkuhlman@vikingcc.com For questions or clanfications on the attached checklist please contact the followmg reviewer as marked PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 X Chns Sexton 760-602-4624 Chns Sexton@carlsbadca gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen Lawrence@carlsbadca gov 1 Greg Ryan 760-602-4663 Gregorv Rvan@carlsbadca gov 1 1 Gina Ruiz 760-602-4675 Gina Ruiz@carlsbadca gov 1 1 Linda Ontiveros 760-602-2773 Lmda Ontiveros@carlsbadca gov n Cindy Wong 760-602-4662 Cvnthia WongOcarlsbadca gov • • 1 1 Dommic Fieri 760-602-4664 Dominic Fieri@carlsbadca gov Remarks: REVIEW # Plan Check No CB 13-1520 Address 2521 Palomar Airport Rd Date 7-19-13 Review #2 Planner Chns Sexton Phone (760) 602-4624 Type of Project & Use Jl Net Project Density N/A DU/AC Zoning C-2-Q General Plan GC Facilities Management Zone CFD (in/out) #_Date of participation Remaining net dev acres (For non-residential development Type of land use created by this permit ) 2 3 Legend ^ Item Complete • Item Incomplete - Needs your action • • Environmental Review Required YES • NO • TYPE DATE OF COMPLETION Compliance with conditions of approval If not, state conditions which require action Conditions of Approval • • Discretionary Action Required YES • NO • TYPE APPROVAL/RESO NO DATE PROJECT NO OTHER RELATED CASES Compliance with conditions or approval'' If not, state conditions which require action Conditions of Approval • Q Coastal Zone Assessment/Compliance Project site located in Coastal Zone"? YES • NO O CA Coastal Commission Authority? YES Q NO • If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402, (619) 767-2370 Determine status (Coastal Permit Required or Exempt) • Q Habitat Management Plan Data Entry Completed'? YES • NO • If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE') • • Inclusionary Housing Fee required YES O NO • (Effective date of Inclusionary Housing Ordinance - May 21, 1993 ) Data Entry Completed'? YES • NO • (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) • • Housing Tracking Form (form P-20) completed: YES • NO • N/A • p-28 Page 2 of 3 07/11 Site Plan K • • Provide a fully dimensional site plan drawn to scale Show North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, nght-of- way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes) Provide legal descnption of property and assessor's parcel number City Council Policy 44 - Neighborhood Architectural Design Guidelines • • 1 Applicability YES • NO • • • 2 Project complies YES • NOO Zoning • • • • 1 Setbacks Front Intenor Side Street Side Rear Top of slope Required Required Required Required Required 2 Accessory structure setbacks Front Required Intenor Side Required Street Side Required Rear Required Structure separation Required Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown K • • K • • K • • • K • 3 Lot Coverage 4 Height 5 Parking Required Required. Spaces Required Shown Shown Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments 1) Please demonstrate how the new roof mounted equipment will be screened An example has been provided OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER Chns Sexton DATE 7-19-13 p-28 Page 3 of 3 07/11 ^ CITY OF CARLSBAD PLAN CHECIf, REVIEW TRANSMITTAL 7- Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www carlsbadca gov 2tt 'i DATE:8/V13 PROJECT NAME: crazy bowls and wraps PROJECTID: PLAN CHECK NO: Cbl31520 SET#: I ADDRESS: 2521 par ste 103 APN: • This plan check review is complete and has been APPROVED by the fire Division. By: cwong A Final Inspection by the Division is required |^ ves • No This plan check review Is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: You may also have corrections from one or more of ttie divisions Usted below. Approval from ttiese divisions may be required prior to ttie issuance of a building permit Resubmitted plans stiould include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 1 1 Chris Sexton 760-602-4624 Chns Sexton@carlsbadca ^ov 1 Kathleen Lawrence 760-602-2741 Kathleen Lawrence@carlsbadca gov 1 1 Greg Ryan 760-602-4663 Gregory Ryan@carlsbadca gov 1 1 Gina Ruiz 760-602-4675 Gma Ruiz@carlsbadca gov 1 1 Linda Ontiveros 760-602-2773 Linda Ontiveros@carlsbadca gov X Cindy Wong 760-602-4662 Cynthia Wong@carlsbadca gov • • 1 1 Dominic Fieri 760-602-4664 Dommic Fieri@carlsbadca gov Remarks: ** APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. Page 1 of 2 THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. Page 2 of 2 Carlsbad Fire Department Plan Review Requirements Category TI, COMM Date of Report. 08-01-2013 Reviewed Name Address VIKING COMMERCIAL CONSTRUCTION ATTN. TODD KUHLMAN 1825 ASTON AV CARLSBAD CA 92008 Permit # CBI31520 Job Name- CRAZY BOWLS & WRAPS- 1003 SF Job Address- 2521 PALOMAR AIRPORT RD CBAD St 103 INCOMFCETE'=*«=%@5itegi,,^gu^^esubmitted for rQ\\^_^^^9m^^^iff'°''?^^^tv^^^^'^^^cdi![moi adequately conduct a review to det^m^^^^jia^^^^ithe applicable codes and/or standards Please review carefully all comments attachg4»«=^fe^^resubmit the necSsS^^«nSa§^^/or^pecifications, with changes "clouded", to this office forrejae'^^'^Happroval Conditions: Cond. CON0006536 [MET] ** APPROVED. THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW Entry- 08/01/2013 By cwong Action: AP BLDG. DEPT COPY RECOMMENDED FOR APPROVAL Daryl K James & Associates, Inc 205 Colina Terrace Vista, CA 92084 T. (760) 724-7001 Email: kitfire(gsbcglobal.net Checked by ROBERT SCOTT Date. July 18. 2013 APPLICANT: Todd Kuhlman PROJECT NAME: Crazy Bowls and Wraps JURISDICTION: Carlsbad Fire Department PROJECT ADDRESS: 2521 Palomar Airport Rd Ste 103 PROJECT DESCRIPTION: CB13-1520, 1,003 di Tl of existing on-story retail shell space for new, small restaurant Work includes new kitchen and cooking equipment, restroom, sales and seating area, mechanical, electncal and plumbing work Space is equipped with existing fire spnnkler system This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department The items below require correction, clarification or additional information before this plan check can be approved for permit issuance COMMENTS -Additional comments made shall be generated by response on revised set A1.0 Deferred Submittals -ADD the following to Deferred Submittal list Commercial Hood & Duct System - 2010 CFC Section 904 -ADD the following note to 'General Notes' The UL300 hood & duct extinguishing system shall be designed in accordance with CFC Sections 904 11, 609 1, 609 2 and 2002 NFPA 17A UL 300 Hood & duct exhaust and extinguishing system plans including manufacturer's Installation & Service Manual Deferred submittal to include, but not be limited to plans providing designed details and dimensions of appliances, hood & duct and extinguishing system in accordance with manufacturer's Installation & Service Manual A C-16 licensed fire protection contractor shall perform all work -ADD Note Provide Class K' Fire extinguisher for kitchen cooking area Fire extinguisher shall be mounted in visible and accessible location within 30 feet of cooking appliances and no more than 5 feet above finished floor, with exact location determined by Carlsbad Fire Dept A1.0 -ADD Note A Fire extinguisher rated at 2A-10bc shall be located to serve the dining and sales area Travel distance to 2A-10bc rated extinguisher shall not exceed 75 feet Indicate location and mounting height of extinguisher (60 inches max A F F ) on plan CFC 906 - ADD Note The demolition contractor shall contact Carlsbad Fire Department pnor to taking existing fire spnnkler system out of service, if system will be out of service overnight Relocation of fire spnnklers in existing space requires Carlsbad Fire Dept approval A3.1 ADD Note to 'Suspended Ceiling Notes' Suspended acoustical ceilings shall comply with section 808 1 and 808 1 1 1 Of 2010 CBC M1.0 ADD Notes to 'Mechanical General Notes and Specs' as follows -ADD Note All Natural Gas piping shall be labeled every 20 feet and every change of direction - ADD note Manual pull station for cooking area protection systems shall be located within 20 feet of cooking appliances Carlsbad Fire Dept shall approve exact location -ADD Note Type 1 Grease Hood (Up-blast) Manufacturer specifications for exhaust duct and fire barner duct wrap shall comply with CA Mechanical Code section 507 and NFPA 96 to achieve proper rating for zero clearance to combustibles PLO ADD Notes to General Notes on plumbing sheet 1 as follows - ADD Note All gas piping on roof shall be labeled every 20 feet and every change of direction with labels that read 'Natural Gas" Gas piping from meter to water heater and all cooking appliances shall be labeled - ADD Note Gas meter shall be identified with sign indicating address (Crazy Bowls-Wraps) that meter serves CPC 1209 6 5 fage 1 01z CORRECTION LIST Daryl K James & Associates, Inc Checked by ROBERT SCOTT Date: July 8. 2013 APPLICANT: Todd Kuhlman PROJECT NAME: Crazy Bowls and Wraps JURISDICTION: Carlsbad Fire Department PROJECT ADDRESS: 2521 Palomar Airport Rd Ste 103 PROJECT DESCRIPTION: CBI3-1520, 1,003 ii Tl of existing on-story retail shell space for new, small restaurant Work includes new kitchen and cooking equipment, restroom, sales and seating area, mechanical, electncal and plumbing work Space is equipped with existing fire spnnkler system This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department The items below require correction, clarification or additional information before this plan check can be approved for permit issuance INSTRUCTIONS FOR EXPEDITED PLAN REVIEW SERVICE • CORRECTIONS OR MODIFICATIONS TO THE PLANS MUST BE CLOUDED AND PROVIDED WITH NUMBERED DELTAS AND REVISION DATES ALONG WITH A DESCRIPTIVE NARRATIVE OF CORRECTIONS ADDRESSING ALL COMMENTS. PLEASE BE SURE TO PUT FIRE REVISIONS ON THE BUILDING DEPT. PLAN CHECK SET. • PLEASE DIRECT ANY QUESTIONS REGARDING THIS REVIEW TO: ROBERT SCOTT 760-331-7907 OR FYRWISE07@GMAIL.COM • CORRECTED PLANS, DESCRIPTIVE NARRATIVE OF REVISIONS FOLLOWING EACH COMMENT ON THIS FORM, AND A COPY OF BUILDING DEPARTMENT (ESGIL) - ONE COMPLETE PLAN CHECK SET (initial or revised) MUST BE DELIVERED DIRECTLY TO THE FOLUDWING ADDRESS TO AVOID DELAY: R6BERTSCOTT 4906 CHAUCER AVE SAN DIEGO, CA 92120 COMMENTS - Additional comments made shall be generated by response on revised set and clouded. A1.0 Deferred Submittals ADD the following to Deferred Submittal list Commercial Hood & Duct System - 2010 CFC Section 904 i:'age z 012 A1.0 -ADD the following note to 'General Notes' -ADD Note The UL300 hood & duct extinguishing system shall be designed in accordance with CFC Sections 904 11, 609 1, 609 2 and 2002 NFPA 17A UL 300 Hood & duct exhaust and extinguishing system plans including manufacturer's Installation & Service Manual Deferred submittal to include, but not be limited to plans providing designed details and dimensions of appliances, hood & duct and extinguishing system in accordance with manufacturer's Installation & Service Manual A C-16 licensed fire protection contractor shall perform all work -ADD Note Provide Class K' Fire extinguisher for kitchen cooking area Fire extinguisher shall be mounted in visible and accessible location within 30 feet of cooking appliances and no more than 5 feet above finished floor, with exact location determined by Carlsbad Fire Dept -ADD Note A Fire extinguisher rated at 2A-10bc shall be located to serve the dining and sales area Travel distance to 2A-10bc rated extinguisher shall not exceed 75 feet Indicate location and mounting height of extinguisher (60 inches max A F F ) on plan CFC 906 - ADD Note The demolition contractor shall contact Carlsbad Fire Department pnor to taking existing fire sprinkler system out of service, if system will be out of service overnight Relocation of fire spnnklers in existing space requires Carlsbad Fire Dept approval A3.1 ADD Note to 'Suspended Ceiling Notes' Suspended acoustical ceilings shall comply with section 808 1 and 808 1 1 1 Of 2010 CBC M1.0 ADD Notes to 'Mechanical General Notes and Specs' as follows -ADD Note All Natural Gas piping shall be labeled every 20 feet and every change of direction - ADD note Manual pull station for cooking area protection systems shall be located within 20 feet of cooking appliances Carlsbad Fire Dept shall approve exact location -ADD Note Type 1 Grease Hood (Up-blast) Manufacturer specifications for exhaust duct and fire barner duct wrap shall comply with CA Mechanical Code section 507 and NFPA 96 to achieve proper rating for zero clearance to combustibles PLO ADD Notes to General Notes on plumbing sheet 1 as follows - ADD Note All gas piping on roof shall be labeled every 20 feet and every change of direction with labels that read 'Natural Gas" Gas piping from meter to water heater and all cooking appliances shall be labeled - ADD Note Gas meter shall be identified with sign indicating address (Crazy Bowls-Wraps) that meter serves CPC 1209 6 5 CARLSBAD CITY OF PLUMBING, ELECTRICAL, MECHANICAL WORKSHEET B-18 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www carlsbadca gov Project Address: Permit No.: Information provided below refers to worb being done on the above mentioned permit only This form must be completed and returned to the Buildinq Division before the permit can be issued. Buildmg Dept. Fax: (760) 602-8558 No o Number of new or relocated fixtures, traps, or floor drains New building sewer line? ., Number of new roof drains? Install/alter water line? lUL^.i?J.9.C.....h^m.b.*:d:iS!t?. BOi-F Number of new water heaters? I Number of new, relocated or replaced gas outlets? S Number of new hose bibs? t!> Residential Permits: . New/expanded service: Number of new amps: ^/Fr— Minor Remodel only. Ves No ^ Commercial/Industrial: Tenant Improvement: Number of existing amps involvedin this project: Number of new amps involvedin tliis proiect: 1^^^ c^^^'^ New Construction: Amps per Panel: Single Phase Number of new amperes Three Phase Number of new amperes _ Three Phase 480 Number of new amperes Number of new furnaces, A/C, or heat pumps? I New or relocated duct worb? Ves ^ No Number of new fireplaces? ^ Number of new exhaust fans? Relocate/install vent? I Number of new exhaust hoods? I Number of new boilers or compressors? Number of HP '' B-18 Page 1 of 1 Rev 03/09 WilMmBMllBii WW Current Limiting Panel An '^cuityBrands Company The Silver8(7//ef" Sub-Branch Circuit Current Limiter Description: Lighting calculations for most energy codes include a deduction for each linear foot of track California's Title 24 "charges" 45 watts/linear foot of track lighting Seattle "charges" 70 watts/foot ASHRAE, 30 watts/foot With today's lighting technology the connected load is far less than the per-foot requirements of these codes The SilverSu/tef, a "Sub-Branch Circuit Current Limiter" solves this requirement by enforcing a definite cun-ent limit to lower the VA rating of each track lighting circuit For example, California's Title 24 would require three track circuits with a total length 100 ft to be calculated at a minimum of 4500 watts (45 watts/foot x 100 ft) With the SilverSu/tef those three tracks could be limited to 8 amps each to reduce the lighting load calculation to 2880 watts (120V x 24 amps) Features: • Current limiting for up to 21 circuits • Current limiting available from 1-8,10,13 & 15 amps • Compact Sizes 12" w x 18" h x 4" d or 12" w x 12" h x 4" d • AIC Rating of lO.OOOA @ 120VAC • Factory pre-assembled • Each load factory labeled on the door sheet • No programming required Specifications: Enclosure dimensions Enclosure type Optional enclosures Certifications Max humidity Ambient temperature 12" w X 12" h X 4" d, (1-12 supplementary breakers) 12" w X 18" h X 4" d, (6-21 supplementary breakers) Surface mount, hinged locking door, NEMA 1 Flush mount Panel complies with UL 508, breakers comply with UL 489 10-90% non-condensing 32-104° F (0-40° C) (Note Thermal magnetic breakers De-rate to 80% of load for temperatures over 70° F) 800-345-4448 • vwwiightingcontrols com How It Works TO ••'•an ••'•an ••'•an ••'•an ••'•an ••'•an ••••an ••'•an •••lan ^••ian'' ••'•an ••'*an ••'lan ••'•an ••'•an: ••'•an ••'*an ;Qii!an: ••'•an 1 o 20 a 20 a 6a 4a Load Center SilverSuZ/ef Track Lighting More Track—Less Penalty The Silver6t///ef is UL Listed to be placed in-line between the branch circuit breaker and the track mounted lighting loads California 2005 Title 24, Section 130 0(3) states: (c) Luminaire power. Luminaire wattage incorporated into the installed lighting power shall be determined in accordance with the following criteria The wattage of line voltage lighting track and plug- in busway which allows the addition or relocation of luminaires without altering the winng of the system shall be the volt-ampere rating of the branch circuit feeding the luminaires This IS what the SilverSu/fef does When doing energy calculations, use the ampere rating of the supplementary breaker in the Silver6u//ef as opposed to the linear footage of the rack No magic Just a Silver6iv//ef SUPPLEMENTAL CURRENT LIMITING PANEL NEMA 1 ENCLOSURE WITH HINGED LOCKING DOOR UP TO 21 CURRENT LIMITERS 12'WX IS'H X6 D ORDERING INFORMATION SilverSu//e( mini COMPACT 12 X 12- X 4" HOUSING FOR 1-12 RELAYS T24M 489UL IBP 2A[1] SM System T24 = Standard (21 breakers max) T24M = Mini (12 breakers max) Breaker UL Listing 489UL = Standard 1077UL = (required for City of Los Angeles) Breaker Positions (qtyJBP = # of positions Where [qty] is replace with the total number of breakers needed in a panel Within a range depending upon the specified panel T24 IS from 6 and 21 breakers T24M is from 1 to 12 Breakers 1A[qly] = 1 amp breaker 2A[qty] = 2 amp breaker 3A[qty] = 3 amp breaker 4Aiqty] = 4 amp breaker 5A[qtif] = 5 amp breaker 6AIqty] = 6 amp breaker 7A[qty] = 7 amp breaker 8A[q^] = 8 amp breaker 10A[qty] = 10 amp breaker 13Aiqty] = 13 amp breaker 15A[qty]' = 15 amp breaker 1 = only available with 1077UL option Where [qty] is replace with the quantity of breakers of that amperage Total quantity of breaker spaces speafied must fall within the number specified under Panel Size 3A2 is two 3 amp breakers 10A10 is ten 10 amp breakers Enclosure Mountings SM = Surface Mount FM = Flush Mount wvwiightingcontrols com • 800-345-4448 ® 2013 Acuity Brands Lighting Inc, All Rights Reserved (0 ^ COUNTY OF SAN DIEGO v% DEPARTMENTOF ENVIRONMENTAL HEALTH ,^)SC PLAN REVIEW Pf^f}\/|?tONAL APPROVAL PLANS ACCEPTED FOR CONSTRUCTION SUBJECyO^ REQUIREMENTS OF THE STATE AND LOCAL REGUlAriONS. ¥5lS STAMP IS NO ASSURANCE THAT THE PLANS FICATIONS ARE CORRECT IN EVERY RESPECJ ERRORS IN DESIGN OR CONSTRUCTIOIitMUST BE CORRECTED. APPROVED SET FOR PLANS MUgt^M/^N ON THi: JOB SITE DURlJ^CONSraTIOM. •a o O c5 LU o 5 5 ^ 5 ULI (D PROJECT NUMBER CARLSBAD FIRE DEPARTMENT EXPEDITED PLAN CHECK REQUEST I, iQ^OQ YAfi^'^O^fM'^ am requesting 'Expedited Plan Check Services' and understand I will Be levied an additional fee assessed at the rate of $90 00 dollars per hour plus $25 00 dollars administration fee I understand that my plans shall not be released until all fees are paid I, yJ^^W^WOt^ the applicant, am solely responsible for all fees due should the project be withdrawn or otherwise not completed And by signing below I acknowledge that my plans shall be irorwarded by the City of Carlsbad to an independent contractor/consultant I, 4^ reviews will be ten- (10) busine acknowledge that the 'first review' time for all expedited fire plan reviews will De t&n- (10) business days from date of submittal These additional day account for acceptance and delivery of your plans and then the parcel return to our office if recommended for approval Your rtamef the applicant, acknowledges that corrected or revised plans shall be sent directiv to the plan checl<er, at the address specified on the Correction List, at my cost, parcel post or other means acknowledge that a turn-around time for re-submittals is //ve- (Sjibusiness days from the date plans are received at the address specified by the plan checker on the Correction List Once all corrections are made, your plans are then returned to the Carlsbad Fire Department with a "Recommendation for Approval" based solely on the adopted Codes and Standards This is not an approval. Your plans are then forwarded to the Carlsbad Fire Department, and once your plans are received by our office they are subject to an additional review to ensure conformance with Carlsbad Municipal Code This additional review is subject to an additional review period of seven- (7) 'Government Business' days from date that we receive the plans from the plan reviewer. The Carlsbad Fire Department does not perform 'Over-the-counter' plan review services Plans submitted to the Carlsbad Fire Department for review by CFD staff shall be checked on a 'first come, first served' basis and could take 10 days or more for 'First' review NO Applicant Signature Copy to Building and Fire Prevention file Date fM^\^ Revised 10/15/2012 CB131520 2521 PALOMAR AIRPORT RD 103 7//^//3 G.'-^ pL/H^ SW •ISSUED •CV Approved Date BUILDING PLANNING ENGINEERING FIRE Expedite?/ AFS Ctiecked by 7/^/3 By HazMat APCD Health Forms/Fees Sent Reed Due? By Encina Fire HazHealthAPCD PE&H/I School Sewer Stormwater Special Inspection CFD Y ^ LandUse Density ImpArea FY Annex Factor PFF N Comments Date Date Date Date Building Planning Engineering Fire Need? 7r//3 a Done • Done • Done • Done • Done • Done