Loading...
HomeMy WebLinkAbout2521 STATE ST; ; CB150438; PermitCity of Carlsbad ' •j 04.,23-2015 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No: CB150438 Building Inspection Request Line (760) 602-2725 Job Address: Pennlt Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: 2521 STATE ST CBAD RESDNTL 2030543401 $305,716.00 1 0 Sub Type: CONDO Lot#: 1 Status: ISSUED Applied: 02/11/2015 Entered By: JMA Project ntle: Constuctlon Type:i.5~ Reference #:\:c:fJ-3_0005____.) Structure Type: MF5+ Bathrooms:~ Orig PC #:~37,....::----'-'..I STATE ST. TOWNHOMES: PHS.1 828 Plan Approved: 04/23/2015 Issued: 04/23/2015 Inspect Area: Plan Check#: PC150021 348 SF 1 ST FLR COMMERCIAU1 ,819 SF LIV/ 450 SF GAR/ 88 SF BALCONY/ 690 SF ROOF DECK Applicant: TAYLOR MORRISON OF CA, LLC STE 1450 100 SPECTRUM DR IRVINE CA 92618-4935 949-341-1289 Building Pennit Add'I Building Pennlt Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park in Ueu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee HMP Fee Pot. Water Con. Fee Meter Size Add'i Pot. Water Con. Fee Reel. Water Cpn. Fee .Green Bldg Stands (SB1473) Fee Green Bldg Stands Plan Chk Fee Total Fees: $1,353.24 $0.00 $947.27 ($500.00) $0.00 $39.74 $6,190.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $3,931.00 FS1 ($3,931.00) $0.00 $13.00 $0.00 Owner. Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWA Fee CFO Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing lnlleu Fee Housing Credit Fee Master Drainage Fee Sewer Fee Additional Fees Fire Sprinkler Fees TOTAL PERMIT FEES $24,224.69 Balance Due: FS1 $0.00 $317.00 $4,800.00 $0.00 $5,564.03 $5,136.03 $0.00 $0.00 $0.00 $0.00 $0.00 $210.00 $89.00 $65.38 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $24,224.69 $0.00 Inspector: Clearance: ------ NOTICE: Please take N approval of yoor project Includes the 'lmpos on' ci , dedications, reservations, or other exactlons hereafter collectlvely referred to as 'fees/exact! have 90 days from the date this permit was Issued to protest Imposition of these teas/exactions. If you protest them, you must follow the protest procedures set forth In Government Code Section 66020(a), and ffle the protest and any other required lnformatlon with the City Manager for processing In accordance wltli Carlsbad Municipal Code SectJon 3.32.030. Failure to tlmely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their Imposition. You are hereby FURTI-IER NOTIFIED that your rfght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connectlon fees and capacity changes, nor planrJng, zoning, gradlng or other similar appUcat!on procasslng or service fees In connection with this project. NOR DOES IT APPLY to any City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 04-23-2015 Storm Water Pollution Prevention Plan (SWPPP) Permit Permit No:SW150155 Job Address: Permit Type: Parcel No: Reference #: CB#: Project Title: 2521 STATE ST CBAD SWPPP 2030543401 Lot#: PC140056 STATE STREET TOWNHOMES 0 Applicant: Owner: TAYLOR MORRISON OF CALIFORNIA STE 1450 8105 IRVINE CENTER DR IRVINE CA 92618 949 341-1289 Emergency Contact: TOM BAINE 714 920-3525 SWPPP Plan Check SWPPP Inspections Additional Fees TOTAL PERMIT FEES Total Fees: $224.00 Total Payments To Date: Status: Applied: Entered By: Issued: Inspect Area: Tier: Priority: ISSUED 04/15/2015 RMA 04/23/2015 PY 1 M $0.00 $224.00 $0.00 $224.00 $224.00 Balance Due: $0.00 FINAL APPROVAL DAT ' Inspection List Pennit#: C8150438 Type: RESDNTL CONDO STATE ST. TOWNHOMES: PHS.1 828 348 SF 1ST FLR COMMERCIAU1,819 SF L Date Inspection Item lnspect~r Act -~---Comments 03/08/2016 89 Final Combo PY AP 03/08/2016 89 Final Combo RI AM PLEASE/COF 11/19/2015 39 Final Electrical PY PA 11/04/2015 34 Rough Electric PY AP 10/05!2015 82 Drywall/Ext Lath/Gas Test PY AP 10/02/2015 82 Drywall/Ext Lath/Gas Test PY NR 09/24/2015 84 Rough Combo PD AP 09/22/2015 84 Rough Combo PY CA 09/14/2015 13 Shear Panels/HD's PY AP 09/11/2015 15 Roof/Re roof PY AP 09/01/2015 17 Interior Lath/Drywall PY PA 08/27/2015 17 Interior Lath/Drywall PY PA 08/21/2015 15 Roof/Reroof PB AP 08/05/2015 17 Interior Lath/Drywall PY PA 06/25/2015 11 Ftg/Foundation/Piers PB AP 06/04/2015 21 Underground/Under Floor PY AP 06/04/2015 22 Sffwer/Water Service PY AP Thursday, Marcil 10, 2016 Page 1 of 1 .. ~, ,,, ,;,; ... CB:1,50438 2521 STATE ST :· STAT~''ST_ towNHOMES: PHS.1 B2B ~ cil'f or i' CARLSBAD ,.. ·1lding Division INSPECTION RECORD 348 SF 1ST FLR COMMERClAU1 ,819 SF LIV/ 450 SF GAR/ 88 SF BALCONY/ 690 SF ROOF DECK RESDNTL CONDO · =-fNSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB Lot#: 1 TAYLOR MORRISON OF CA, LLC @ CAll BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION 0 FOR BUIIDlNG INSPECTION CAll: 760-602-2725 RECORD COPY Required Prior to Requesting Buikflng Anal If Checked YES Planning/Landscape Mow48 hours,.,,,.. CM&l (Engineering !ruf=tions) 760-438-3891 Callbefo_!'J!2pm Are Prevention 76Q-602-%60 / Al!9W 48 hours Type of Inspection ·. c.oo~·,; .:· ELECTRICAL . ·.. . · .. Date lnsptM:tor lt31 0 UECTRIC UNDERGROUND DUFER "iG MASONRY PRE GROUT 1133 0 ELECTRIC SERVICE O TEMPORARY ___,.. 0 GROUT O WAll DRAINS . lt35 PHOTO VOLTAIC CC.DE# ·MECHANICAL: ... ' #11 COW MN FOOTINGS #41 UNDERGROUND DUCTS & PIPING . Ccicnnl . COMBO INSPECTION ' . .'· .. #18 EXTERIOR LATH 1#81 UNDERGROUND (11,12,21,31) #17 INTERIOR LATH & DRYWAU #82 DRYWAl.l,EXTlATH, BASTES (17,18,23) #51 POOL EXCA/STEEL/BOND/FENCE #83 ROOFSHEATJNG, EXT SHEAR (13,15) #55 PREPI.ASTO!/ANAL #84 FRAME ROUGH COMBO ( 14,24,34.44) J/85 T-Bar (14,24,34,44) FINAL OCCUPANCY (19,29,39,49) _#28 __ s_oLAR __ W_ATE_R _____ ~--+-~~---+~~-~~+--A~/S_O_VER_H~EADHYDROSTATIC lt29 ANAL A/S ANAL F/AROUSH-IN #600 PRE.CONSTRUCTION MEETING F/A FINAL /i' _ ~,:'..,,.~ ~3 FOUOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN ~S NOTICE TO CLEAN F1X£D EXTING SYSTEM HYDROSTATIC TEST H601 WRITTEN WARNING FIXED EXTINGUISHING SYSTEM ANAL ---'--#609.:_.c._NO;;..Tl_C:_E....cO.;._F_Vl_O_LA_:OO_N ____ ,__ ___ -+------+-M_E_D_ICA_L GAS PRESSURE TEST 11610 VERBAL WARNING MEDICAL GAS ANAL REcV 10/2012 SEE BACK FOR SP!cC1Al NOTES Ctwtintwlls l11sp<'ctio11 & Matcrfrlfr ft'sn·r1g SOUTHWEST *~~~:t-~~¢-e~~~~~~ Inspection & Testing, Inc. 44 l Comn1t"fCial WRy, La Habra. CA 906.i l-6160 {5()2) 941-2990 • (714) 526-844 I fAX (562) 946-0026 October 12~ ·201s Building Offlclal City of Carlsbad Department of Building and Safety 1635 Faraday Ave car_lsbad, Callfornla 92008 SPECIAL INSPECTOR'S FINAL PROJECT REPORT Project Name: Address: Owner. Seagrove Townhomes state·street, PH 2 Bulldlng 4 Taylor Morrison Unit# Address 1 2521 State street 2 2525 .State Street 3 2529 State Street 4 2533 State street ·s 2537 State s.treet Permit CB150438 CB150442 CB'150446 CB150447 CB150448 Unit# Address 6 2541 State Street 7 2545 State street a 2549 state street 9 2553 State Street Permit. CB150449 CB150450 CB150451 CB150452 This Is to certify that Southwest lrispectlon and Testing, Inc. was employed to perform specfal lh~pectlon on the above mentioned project at the above address, which required continuous inspection per section 1701 of 2013 californla Building Code. Brett Alblinger -Reinfbrced Concrete, Post Tensioned Concrete, Sb #656 William Bowen -Reinforced Concrete, Post Tensioned Concrete, SD #541 Tom Woods-Reinforced Concrete, Post Tensioned Concrete, SD # 377 Bqsed upon special inspe·ctlon and materials testing written reports of this work, it is our judgment that the Inspected wprk was perforn:,'ed to the best of our knowledge, In accordance with the approved plans, specifications and applicable workmanship provision o · · · · · nia Building Code. ,WAD Reviewed By: < < {'city of Carlsbad CIRCUIT CARD B-36 Development Services Building Division 1635 Far13day Avenue 76D-602-2719 . www:carlsbadca.gov THIS CARD MUST BB FilLBD Otrr AND AV AILABLB AT THB SER.VICE"" l1IPMENT POR THE ROUGH INSPECTION Address: 1 S' l.. I ..J-J',I ;~ S-M 6-t1-r r.4~ ,,,~(> NJ QUrJJ" Permit Number: CA I . .J"o "/.38' OWner. -1'4'/ ,_ A .fa~.,,,.,/ Phone: (1'/FJ' 3'/J-I"""'' Area In Sq. A. ':21 /g6 Contractor: 'SCH-i <.(.J N <J -f A R/14'Sf:_ Phone: l.p{C/ 579 ~OC) P ANBL: B-li-,e..AGe /0 l ~00 A.LC. ';Z>i 0 VOLTS I 0 ~ WIRE BKR WIRE I 11'>;.sc, WIRE BKR LOCATION CKT l.n;.. REC REC LTG CKT LOCATION SIZE SIZE TYPE SIZE TYPE SIZE 8.ltTHMi 1 :zo 1.2.. Cv 5· I ('/ ~<J I '5 2 Fl.C .:t rl4u 3 ;z_o ,~ Cu I . ~ 2-1¥ C.t...} 15 4 G,<J~.46-E. µ.,r~HG,J 5 :Z(Y I 2. C.l) t./ 6 R :2-I 1../. C..L) ,~ 6 nll'J?..,' .,.. L.J WPtSllefe.. 7 :;2. 0 /1. CV I "I 7 I I~ C (.) IS' 8 1--~~r/1>~ /:(J!~Ju:~ 9 ·. /€5 I 'I CtJ I ~ '7 ~ /4, <:..O I ,:::-10 BEO 7-- Pl~P'0$1it.. 11 l':5 /'c/ cu I 5 '7 ;L I</ c..u JS 12 IJ:ir F<.O~ M IC°Jtl .. C; 1·3 :,._c, J 1. Cv I I,. {--1 /4 C. () JS 14 LI VIN6 ---' /<JTc.llEI/ 15 :)_Q /::J. cu 4 LI ?-14 CV 15 16 /3Gt=> 3/~ /Y/INI 17 :zo· / 'J-cu '2.40 v. ~ 7 q I</. cu ,~ 18 ~ I TCf//iN :j~l..lt 19 ;l,O /-:L C<.J D e;p I .. . 20 Ale 21 .;is /tJ c.u ~ ~o, 22 Ale 23 ;i.~ JD Cl./ D !l;o , 24 25 26 27 28 29 30 31 32 33 34 35 36 • 37 38 39 \ 40 41 42 MAIN: 0 f~S" AMP BRK/FUSE O MLO Computed Load 14:, '.p~ AMPS BUS: AMP s .. Calcut.tion w~ on t/Qck 2-~ Branch circuits required: Service entrance or f&eder conductors: ~ A) Lighting Circuits 220 -3(b), 4(d) A) Size: No. 2-/-£ B) Type: D cu AL B) TWo Small Appliance Circuits 210-11(e) C) Insulation: :u! D) Conduit Size: __ C) Laundry Circuit 220-16(b) Service ground/bond: • D) Central Heating Equipment 422-12 A) Size: No. '3 (o B) Type: )(cu D AL E) Bathroom 210 -52(d) ~ Clamp locatlon(s : ' ' UFER 250 -50(c) Remarks: Water Pipe 250 -104 0 Ground Rod 250-52 0 Gl locat!ons 210-8, 680-70: bf Kitchen / certlf'/ that all farm/nations have ~en torqued In BCCO[dance with manufectur9r's Bathroom(s) /nstruct}ons and that the -work shown on this cJrcuft carrf-represent! the full extent of Garage(s) ' . OHydrumassage Tub the work perform9d under this permit. l/ OUtdoors 0 0 OWner A 'Protected Clrc. 210-12 -~ Contractor.:S c.7J /1.,l., Al~ t-';+~ A .ll 1~~ Bedroom( s) "J8l G, U E', R. y w H~ /!..E. Slg ·-0 .--·-. \Y Date -, I.., I 1.~ , U' lu . , (l -') . Page 1 of2 Rev. 03/09 'Ci ~A SINGLE FAMILY DWELLING ELECTRICAL SERVICE LOAD CALCULATION As an sltematlve method, the STANDARD METHOD found-In ARTICLE 220,ofthe National E/ectrlc Co<!e. may be used 1. GENERAL LIGHTING LOADS Dwelling :;i., /8/) sq. ftx 3. VA= 220-3(a) tq, S'-lb VA Small appllan~ loads -220-16(a) 1500 VA x '2._. circuits c 3, ooe> VA Laundryloa.P_-220-16(b)1500VAx circuits= /!SZJO VA · · General Ughtlng Total . 2. ·coOKING-·EQUIPMENT· LOADS-Nameplate Value· ·~ge-·.,-· VA= -VA Cooktop -VA= -VA Oven (s) VA= ..... . VA If, 0 </fJ ·VI!-- . Cooking Equipment Total. _______ . VA 3. .ELECTRIC DRYER 220-18 (Nameplate, 5000 VA minimum) . l;)r:yer . ··--VA=· Dryer.Total __ ~ __ .. __ VA 4. . · F~:E!;)--APPLIANCE LOADS 230-30 (b) (3) . Dishwasher = .Ql~a . COmpactbr = ·.wate{Heater = · ·HydrQmas~ge Bathtub= Microwave Oven = BuUt~tn Vacuum = = 5. OPTIONAL SUBTOTAL (Add all of the above totals) 6. APP.LYING DEMAND FACTORS-TABLE 220-30 · · ... .. · · .··Flrst 10,000VAx 100% ~ Optional Subtotal (from fine 5) { Rem~lnlng :{i] 'fOVAx40%a • ·1. HEATING ,OR AC LOAD -TABLE.220-30 ·La~~r of the·Heijtlng or AC Load= //;;~~ VA 7Sb VA ____ VA· _____ VA VA -...... Z'"""s .... 0.,,..5--vA _____ VA _____ VA Fixed Appliance Total '3 /7 'SOvA ./Cf, '7 '10 VA ' 10,000VA ,, q l ~ VA ~lOf:.'10 VA 8. OPTIONAL LOA.D.S-TOTAL (Add totals from lines 6 and 7) = lt,q{b VA 9. MINIMUM S~RVICE $1ZE m Optional Loads Total = 71..l, 4>S Ampere :·: . . . · 240 Volt (Please put total oh fronf of card under. Computed Load) . -. ',,·, ~~ ... . ,' ~ ,;.