Loading...
HomeMy WebLinkAbout2522 West Ranch St; ; CB161993; Permit(city of Carlsbad Print Date: 12/26/2018 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2522 West Ranch St BLDG-Residential 2081951000 $2,129,655.00 ROBERTSON RANCH WEST VILLAGE Residential Permit Work Class: Apartments Lot#: Reference#: DEV11017 Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection; Description: RESDNTL · APT MONTECITO: 13 UNIT APT BLDG TYPE l / 14,924 Sf APT AREA/ 2,447 Sf GARAGE (BLDG #11) Applicant: ALLIANCE LAND PLANNING AND ENGINEERING INC ELIZABETH SHOEMAKER 2248 Faraday Ave Carlsbad, CA 92008-7208 760-431-9896 Total Fees: Owner: SHAPEL MONTECITO LLC 8383 Wilshire Blvd, Suite 400 Beverly Hills, CA 90211-2400 323-988· 7590 Total Payments To Date: Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Permit No: CB161993 Closed -Finaled 05/19/2016 10/11/2016 MColl 12/26/2018 12:30:02PM 1635 Faraday Avenue, Carlsbad, CA 92008-7314 [ 760-602-2700 I 760·602-8560 f I www.carlsbadca.gov Permit Print Date: 01/04/2019 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: Description: FEE Total Fees: Building Division 2522 West Ranch St BLDG-Migrated 2081951000 $ 0.00 Work Class: BLDG-Migrated Lot#: Reference#: DEVllOl 7 Construction Type Bathrooms: Orig. Plan Check#: Plan Check #: ROBERTSON RANCH WEST VILLAGE SWPPP -MONTECITO APARTMENTS BUILDING #11 Tota I Payments To Date : Status: Applied: Issued: Permit Fina led: Inspector: Final Inspection: (city of Carlsbad Permit No: SW160474 Closed -Finaled 09/27/2016 10/11/2016 01/04/2019 AMOUNT Balance Due: 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov . . PERMIT INSPECTION HISTORY REPORT (CB161993) Permit Type: Work Class: Status: Scheduled Date BLDG-Residential Application Dato: 05/19/2016 Apartments Issue Date: 10/11/2016 Closed -Finaled Expiration Dato: 06/10/2019 IVR Number: 714662 Actual Start Date Inspection Type Inspection No. Inspection Status Checklist Item COMMENTS Partial 12/26/18 Owner: Subdivision: Address: Primary Inspector BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Mechanical Final BLOG-Structural Final BLDG-Structural Final BLDG-Electrical Final BLDG-Electrical Final TCO see the back of inspection card ···-··-···~----···-·--------- Oecember 26, 2018 SHAPEL MONTECITO LLC 2522 West Ranch St Carlsbad, CA Re inspection Passed Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Complete Page 9 of9 ' . · . , PERMIT INSPECTION HISTORY REPORT (CB161993) Jf' ' Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: SHAPEL MONTECITO LLC Work Class: Apartments Issue Date: 10/11/2016 Subdivision: Status, Closed -Finaled Expiration Date: 06/10/2019 Address: 2522 West Ranch St Carlsbad. CA IVR Numbor: 714662 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete 03107/2018 03107/2018 BLDG-23 050982-2018 Passed Michael Colltns Complete Gas/Test/Repairs Checklist Item COMMENTS Passed BLDG-Building Deficiency Test for all units Yes 05/24/2018 05/24/2018 BLDG-33 Service 059018-2018 Passed Michael Collins Complete Change/Upgrade Checklist Item COMMENTS Passed BLDG-Building Deficiency EMR emailed to SDGE Yes 08/22/2018 08/21/2018 BLDG-Final 067551-2018 Partial Pass Chris Renfro Relnspection Incomplete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final TCO see the back of inspection card Yes BLDG-Electrical Final Yes 12/11/2018 12/11/2018 BLDG-Fin al 078420-2018 Partial Pass Michael Collins Reinspectlon Incomplete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Partial Yes BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final TCO see the back of inspection card Yes BLDG-Electrical Final Yes 12/24/2018 12/2412018 BLDG-Final 079792-2018 Cancelled Paul Bumette Reinspection Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Building Deficiency Partial Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final TCO see the back of inspection card Yes BLDG-Electrical Final Yes 12/26/2018 12/26/2018 BLOG-Final 079854-2018 Passed Michael Collins Complete Inspection December 26, 2018 Page 8 of 9 , . PERMIT INSPECTION HISTORY REPORT (CB161993) Pcrrnit Type: BLDG-Residential Application Date: 05/19/2016 Owner: Work Class: Apartments Issue Date: 10/11/2016 Subdivision' Stall.is: Closed -Finaled Expiration Date: 06/10/2019 Address: Scheduled Date Actual Start Date 02128/2018 02/2812018 03/01/2018 03101/2018 0310212018 0310212018 December 26, 2018 IVR Nurnbor: 714662 Inspection Type Inspection No. Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-17 Interior Lath/Drywall 049809-2018 Checklist Item BLOG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-17 Interior LathfDrywall 050327-2018 Checklist Item BLDG-Building Deficiency BLOG-82 Drywall, Exterior Lath, Gas Test, Hot Mop 050150-2018 Checklist Item BLDG-Building Deficiency BLDG-17 Interior Lath-Drywall BLOG-18 Exterior Lath and Drywall BLDG-23 Gas-Test-Repairs BLDG-17 Interior LathlDrywall 050280-2018 Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-82 Drywall, Exterior Lath, Gas Test, Hot Mop 050281-2018 Checklist Item BLDG-Building Deficiency BLDG-17 Interior Lath/Drywall 0S0578-2018 Checklist Item BLOG-Building Deficiency BLDG-Building Deficiency BLOG-Building Deficiency BLOG-Building Deficiency Inspection Status COMMENTS Not ready Not ready Partial Pass COMMENTS Not ready Units 302-305 only 3rd level roof nailing Partial Pass COMMENTS Units 202,204-205 only Cancelled COMMENTS Wrong code Failed COMMENTS Units 302-305 only Not ready Primary Inspector Mlchael Collins Michael Collins Michael Collins Michael Collins Not ready, needs scrapping out 3rd level roof nailing Cancelled Michael Colllns COMMENTS Wrong code Passed Michael Collins COMMENTS Not ready, needs scrapping out Units 302-305 only Not ready 3rd level roof nailing SHAPEL MONTECITO LLC 2522 West Ranch St Carlsbad, CA Reinspection Passed No No Reinspection Passed No Yes Yes ReinspecUon Passed Yes Reinspection Passed No No No No Reinspection Passed Yes No Yes Yes Reinspection Passed No Passed Yes Yes No Yes Complete Incomplete Incomplete Complete Complete Complete Complete Page 7 of 9 ' ' PERMIT INSPECTION HISTORY REPORT (CB161993) " Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner· Work Class· Status: Scheduled Date 02/13/2018 02/14/2018 02/1512018 02(1612018 02/21/2018 02/27/2018 Apartments lssuo Date: 10/11/2016 Subdivision: Closed -Finaled Expiration Date: 06/10/2019 Address: Actual Start Date 02/13/2018 02/14/2018 02115/2018 02(16(2018 02(21/2018 02127/2018 IVR Number: 714662 Inspection Type Inspection No. BLDG-18 Exterior 048695-2018 Lath/Drywall Checklist ltein BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-84 Rough 048785-2018 Combo(14,24,34,44) Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers BLDG-84 Rough 048923-2018 Combo(14,24,34,44) Checklist Item BLDG-Building Deficiency BLDG-84 Rough 049107-2018 Combo(14,24,34,44) Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding {Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers BLDG-16 Insulation 049361-2018 Checklist Item BLDG-Building Deficiency Checklist Item BLDG-Building Deficiency BLDG-14 050029-2018 Frame/Steel/Bolting/ Welding (Decks) Inspection Status Primary Inspector Passed Michael Collins COMMENTS 1st floor and stairwells Partial exterior only at 2nd & 3rd floors Not ready Partial Pass Michael Collins COMMENTS Units 302-305 Partial Pass Michael Collins COMMENTS Units 101-103, 201-205, 301, no garages Passed Michael Collins COMMENTS Completion of garages, minor pick up Cancelled Michael Collins COMMENTS Duplicate COMMENTS Includes RC installation at Units 202-205, 302-305 only Failed Michael Collins December 26, 2018 SHAPEL MONTECITO LLC 2522 West Ranch St Carlsbad, CA Reinspection Complete Complete Passed Yes No No Relnspection Complete Passed No No No No No Reinspection Incomplete Passed No Complete Passod Yes Yes Yes Yes Yes Reinspection Complete Passed No Passed No Reinspectlon Complete Page6of9 ' , PERMIT INSPECTION HISTORY REPORT (CB161993) Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: SHAPEL MONTEC\TO LLC Work Class: Apartments Issue Date: 10/11/2016 Subdivision: Status: Closed -Finaled Expiration Date: 06/10/2019 Address: 2522 West Ranch St Carlsbad, CA IVR Number: 714662 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency No 01/22/2018 01/22/2018 BLDG-14 046388-2018 Falled Michael Collins Reinspection Complete Frame/Steel/Bolting/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Not ready No BLDG.SST-Bar, 046389-2018 Failed Michael Collins Reinspectlon Complete Celllng Grids, Overhead Checklist Item COMMENTS Passed BLOG-Building Deficiency Not ready No 01(2312018 01(23(2018 BLDG-14 046557-2018 Failed Michael Collins Reinspection Complete FramefSteelfBolting/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No 01/24/2018 01/24/2018 BLDG-14 046915-2018 Passed Michael Collins Complete Frame/Steel/Bolting/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Hard lid prelim at drops, stairwells, Yes decks/balconies. BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Not ready No 02/0712018 02/07/2018 BLDG-18 Exterior 048131-2018 Failed Michael Colllns Reinspection Complete LathfDrywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No 02/09/2018 02/09/2018 BLDG-18 Exterior 048348-2018 Failed Chris Renfro Reinspection Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No 02/12/2018 02/12/2018 BLDG-18 Exterior 048662-2018 Partial Pass Michael Collins Relnspectlon Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Partial exterior only at 2nd & 3rd floors No BLDG-Building Deficiency Not ready No ·--¥•-»-~' December 26, 2018 Page5of9 " PERMIT INSPECTION HISTORY REPORT (CB161993) Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: SHAPEL MONTECITO LLC Work Class: Apartments Issue Date: 10/11/2016 Subdivision: Status Closed -Finaled Expiration Date' 06/10/2019 Address· 2522 West Ranch St Carlsbad, CA IVR Numbor: 714662 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Checklist ltom COMMENTS Passed BLDG-Building Deficiency 3rd floor exterior only Yes 01/04/2018 01/0412018 BLDG-18 Exterior 045206-2018 Partial Pass Michael Colllns Relnspection Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Prelim gas line fire caulking at exterior wall Yes 0110812018 01/08/2018 BLDG-13 Shear 045282-2018 Failed Michael Collins Reinspectlon Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Dog house prelim not ready No BLDG-14 045283-2018 Passed Michael Collins Complete Frame/Steel/Baiting/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Prelim before electrical chase installation Yes BLDG-18 Exterior 045284-2018 Passed Michael Collins Complete LathfDrywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Prelim at garages for installation of Yes electrical chase 01(17(2018 01117/2018 BLDG-18 Exterior 045954-2018 Cancelled Michael Collins ReinspecUon Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No 01(18/2018 01/18(2018 BLDG-14 046183-2018 Failed Michael Collins Relnspection Complete Frame/Steel/Bolting/ Welding {Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Not ready No BLOG-17 Interior 046182-2018 Failed Michael Collins Reinspection Complete Lath/Drywall Chocklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-Building Deficiency 3rd level roof nailing Yes 01/19/2018 01/19/2018 BLDG-18 Exterior 046249-2018 Cancelled Michael Collins Reinspection Complete Lath/Drywall December 26, 2018 Page 4 of 9 ' ' , PERMIT INSPECTION HISTORY REPORT (CB161993) " " ' Permit Typo· BLDG-Residential Application Date: 05/1912016 Owner: SHAPEL MONTECITO LLC Work Class: Apartments lssuc Date: 10/1112016 Subdivision: Status: Closed -Finaled Expiration Date: 0611012019 Address: 2522 West Ranch St Carlsbad, CA IVR Number: 714662 Scheduled Actual Inspection Type Date Start Date Inspection No. Inspection Status Primary Inspector Re inspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Test not ready No BLOG-Building Deficiency Blow out No 11/22/2017 11/22/2017 BLDG-22 041335-2017 Failed Michael Collins Re inspection Complete Sewertwater Service Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-24 041334-2017 Passed Mlchael Collins Complete Rough/Topout Checklist Item COMMENTS Passed BLDG-Building Deficiency Waste/vent. See card for additional notes Yes BLDG-Building Deficiency Test not ready No BLOG-Building Deficiency Blow out No 11/28/2017 11/28/2017 BLDG-14 041611-2017 Failed Mlchael Collins ReinspecUon Complete Frame/Steel/Bolting/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-15 041677-2017 Passed Michael Collins Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Truss walk complete with minor pick up Yes BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Complete B-vents and drag nailing No 12/01/2017 12/01/2017 BLDG-27 Shower 042024-2017 Withdrawn Andy Krogh Relnspectlon Complete Pan/Tubs Checklist Item COMMENTS Passed BLDG-Building Deficiency No 12/06/2017 12/06/2017 BLDG-27 Shower 042764-2017 Passed Michael Collins Complete Pan/Tubs Checklist Item COMMENTS Passed BLDG-Building Deficiency Prelim tub trap at Unit 303 Yes 12I1S/2017 12/1S/2017 BLOG-13 Shear 043606-2017 Passed Andy Krogh Complete Panels/HO (Ok to wrap) 12/21/2017 12121/2017 BLDG-13 Shear 043866-2017 Passed Michael Collins Complete Panels/HD (ok to wrap) December 26, 2018 Page 3 of 9 PERMIT INSPECTION HISTORY REPORT (CB161993) Permit Typp· BLDG-Residential Application Date: 05/19/2016 Owner: SHAPEL MONTECITO LLC Work Class: Apartments Issue Date: 10/11/2016 Subdivision. Slatlis: Closed -Finaled Expiration Date: 06/10/2019 Address: 2522 West Ranch St Carlsbad, CA IVR Number: 714662 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re inspection Complete 09/15/2017 09/15/2017 BLDG-15 034801-2017 Falled Mlchael Collins Reinspection Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Complete B-vents and drag nailing No BLDG-16 lnsulatlon 034799-2017 Passed Michael Collins Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Mechanical well Yes BLDG-Building Deficiency Mechanical platforms No 09(1912017 09(19(2017 BLOG-15 035037-2017 Failed Michael Collins Reinspectlon Complete Roof/ReRoof (Patio) Checklist ltem COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Complete B-vents and drag nailing No 09/21/2017 09/20/2017 BLDG-15 035263-2017 Failed Michael Collins Reinspectlon Complete RooflReRoof (Patio) Checklist Item COMMENTS Passod BLOG-Building Deficiency Not ready No 09/22/2017 09/22/2017 BLDG-15 035721-2017 Passed Michael Collins Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Sheathing nailing and penetrations only, Yes need truss walk BLOG-Building Deficiency Not ready No 09/25/2017 09/25/2017 BLDG-15 035675-2017 Cancelled Mlchael Collins Reinspection Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Complete B-vents and drag nailing No 11/20/2017 11/2012017 BLDG-24 041036-2017 Failed Michael Collins Reinspection Complete Rough/To pout Checklist Item COMMENTS Passed BLDG-Building Deficiency Blow out No 11/21/2017 11/21/2017 BLDG-24 041180-2017 Falled Michael Colllns Relnspection Complete RoughfTopout December 26, 2018 Page 2 of9 PERMIT INSPECTION HISTORY REPORT (CB161993) Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: SHAPEL MONTECITO LLC Work Class: Apartments Issue Date: 10/11/2016 Subdivision: Status: Closed -Finaled Expiration Date: 06/10/2019 Address: 2522 West Ranch St Carlsbad, CA IVR Number: 714662 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete 12121/2016 BLDG-21 006764-2016 Passed Michael Collins Complete UndergroundfUnderf loor Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 12/22/2016 1212212016 BLDG-22 006715-2016 Passed Paul Burnette Complete Sewer/Water Service Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 01/30/2017 01/30/2017 BLDG-11 011789-2017 Passed Michael Collins Complete FoundatlonfFtg/Pler s (Rebar) 05/24/2017 05/24/2017 BLDG-14 024505-2017 Passed Michael Collins Complete FramefSteelfBolttngf Weldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency 2nd floor, floor sheathing drag nailing/ CS Yes straps 06/30/2017 06/3012017 BLOG-17 Interior 027647-2017 Partial Pass Jonathan West Reinspection Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency 3rd level roof nailing Yes 08/1012017 08/10/2017 BLDG-15 031404-2017 Failed Michael Collins Reinspection Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Complete B-vents and drag nailing No 0811112017 0811112017 BLDG-15 031419-2017 Cancelled Andy Krogh Reinspection Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Complete B-vents and drag nailing No 08/16/2017 08/16/2017 BLDG-15 031657•2017 Failed Michael Colllns Reinspection Complete RooffReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Complete 8-vents and drag nailing No 0911112017 09/11/2017 BLDG-16 Insulation 034242-2017 Falled Michael Collins Reinspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Mechanical platforms No December 26, 2018 Page 1 of 9 ,~, RECORD C OPY ~ Clt f OF C8161993 2522 WEST RANCH ST CARLSBAD INSPECTION RECORD Building Division MONTECITO: 13 UNIT APT BLDG TYPE 1 / 14,924 SF APT AREA/ 2,447 SF GARAGE (BLDG #11 ) RES0NTL APT 0 INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE .JOB Lot#: 1 ALLIANCE LAND PLANNING & Ii'! CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION Ii'! FOR BUILDING INSPECTION CALL: 760-602-2725 OR GO TO: www.Carisbadca.qoy/Byildlng AND CLICK ON MRequest lnspectlonH · DATE: -\\.p ENGINEERING INC If "YES" is checl,ed below that Division's approval is required pr_ior to requesti_ng a Final Building Inspection. If you have any questions please call the applicable divisions at the phone numbers provided below. After all required approvals arc signed ofl -fax to 760,602-8560. email to hldgi_nspf!<:tiorist00c::_;:irlshadca.gCJv or bring in a COPY of this card to: 1635 Faraday Ave .. Carlsbad. Required Prior to Requesting Building Final If Checked YES Plannlng,'landscape 760-944-8463 Allow 48 hours CM&I {Engineering lnspecllonsl 76().438-3891 Call before 2 pm Fire Prevention 760-602-4660 Allow 48 hours #12 REINFORCED STEEL #66 MASONRY PRE GROUT □GROUT □ WALL DRAINS #10 TILT PANELS #11 POUR STRIPS #11 COLUMN.FOOTINGS #41 UNDERGROUND DUCTS & PIPING #14 SUBFRAMI! 0 ROOR D CEILING #44 0 DUCT & PLENUM O REF. PIPING #15 ROOF SHEATHING #43 HEAT-AIR COND. SYSTEMS #13 #16 INSULATION coo"" COMBO INSPECTION #18 EXTERIOR LATH , #81 UNDERGROUND (11,12,21,31) #17 #B2 DRYWALL.EXT LATH, GAS TES (17,18,23) #51 #83 ROOF $HEATING, EXT SHEAR (13,15) #55 #84 FRAMEROUOHCOMB0(14,24,34,44) o'Z, #85 T-Bar (14,24,34,44) FINAL OCCUPANCY (19,29,39,49) Date Ins ector #21 #24 TOP OUT □ WASTE □ WTR A/S UNDERGROUND VISUAL #27 TIJB & SHOWER PAN A/S UNDERGROUND HYDRO #23 GAS TEST OGAS PIPING A/S UNDERGROUND RUSH / #25 WATER HEATER A/S OVERHEAD VISUAL #2B A/S OVERHEAD HYDROSTATIC A/SANAL F/A ROUGH-IN F/AFINAL #603 FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN #605 NOTICE TO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST #607 WRITTEN WARNING FIXED EXTINGUISHING SYSTEM FINAL #609 NOTICE OF VIOLATION MEDICAL GAS PRESSURE TEST #610 VERBAL WARNING MEDICAL GAS ANAL REV 100012 see BACK FOR SPECIAL NOTES Project l✓o.: I Report No.: lf-L--'-='--'--'-'..L'Ll-'----Y.-LI!C>~~~-J..Hc,--L._C'I tJ?;/J"/.-3-c,-7 1 Author: I I Date: I I / ·39,Ji-· I \OA I 'I i -~ 1( 1 Superintendent: Contractor: Soil Engineer: ili ~ rru r Unit/Phase/Lots: Overcast Plan File No. Day: (c'lrcle one) @TWTFSS Foreman: Cru-_ Rainy Other: Permit No. ' ~ ' \ ~ do \: ' i 14 bJ.",.VJrn ; n i~i.~ io lnitials:.......,,Qfj'-'---'-__ _ Date: ~)-,...t?,1,...=-,· t~t7~-, lnitials:_~Q~ft'-~ Date: . _,I+'! ?P-=l/_,__1 J~_ -, 1 Initials: ot\: Date I /30,/;7 Initials:~ Date: ~ Notes: Observation Summary: A representative of LGC Valley, Inc. observed the on-site soil conditions. The soil conditions at the site are substantially in conformance with those assumed in the geotechnical report. A representative of LGC Valley, Inc. observed the footing excavation(s). The footing excavation(s) extend into the proper bearing strata and are in general conformance with the recommendations of the geotechnical report. A representative of LGC Valley, Inc. measured the footing setback from the slope face. The setback was in general accordance with the recommendations of the geotechnical report. J~r~wv~~~~ ~ons~~v:*=¼ ~~~" _onl; in clj I\ ~ {~ -'t)0~ er. n of ~\ I b ' i I'\ 'ek:"o . 1. Footing excavations should be cleaned of loose debris and thoroughly moistened just prior to placing the concrete. 2. Based on the expansion potential of the underlying soils, presoaking of soil below slabs may be recommended. Consult the geotechnical report for the presoaking recommendations. We note that clayey soils may take an extended period of time and the contractor should schedule accordingly. 3. In the event of a site change subsequent to our footing observation and prior to concrete placement (i.e. heavy rain, a construction/placement delay, etc.), we should be contacted to perform additional site observations, as necessary. 4. Line and grade of the footing excavation(s) are not part of the purview of LGC Valley, Inc. 5. Soil compaction test results, including depth of fill, relative compaction, bearing values, and soil expansion index test results are contained in the As-Graded Geotechnical Report provided at the completion of grading. FOOTING OBSERVATION SUMMARY Date Received by: Print: White -File Copy Yellow-Client Copy Technician Hours LGC VALLEY, INC. Geotechnical Consulting Pink -Field Copy Gold -ClienUAgency Copy DAIL V REPORT Monday, Jan 30, 2017 Robertson's Ranch, Montecito Robertson\'s Ranch West Village Carlsbad , Ca Job#:1016519 WEATHER Time 07:0SAM 12:00PM TIME ARRIVAL Temp 57 °F 69°F 06:59 AM RobertVanderPol, II 0700 REFERENCED DOCUMENTS Hum W-Dir 36% SSW 51% SSW 09:36 AM Robert VanderPol, II Approved PT plans. PT shop drawings. PERMIT NUMBERS 09:36 AM Robert VanderPol, II CB-161993(#11) CB-154586 [Rec #16) ~ ··-~ INSPICTION RIC:OllD -~--ie..... ..... ..,.... fUIIIII....,...,, .. .. aCMl. ....... ,__.._MI ____ .,_ ........ .......,..<M,lt,...._.,.,.,. :.::..--..;::... , .. CMII. .. ...... Powered By Note Vault W-Speed 4MPH 11MPH W-Gust 6MPH 12MPH Precip Condition 0 IN Clear 0 IN Clear Nova Services, Inc. I Robertson's Ranch, Montecito I Monday, Jan 30, 2017 I Page 1 of 4 PRESTRESSED CONCRETE 07:15 AM Robert VanderPol, II Counted tendons in building 11. Tendon count matches PT shop drawing for type 1 building. Outline and tendon count matches type 1 building but reversed (i.e. mirror image). 02:54 PM Robert VanderPol, II Completed inspection of rebar installation for building #11. Checked size, grade, spacing, laps, shapes, bar counts, tendon counts, tendon profiles and hold down sizes & embedments per plans. All noted problems corrected. Clearances and cleanliness to be checked at time of casting. Cruz[Etivista], and Pete [TBP) were informed. Powered By Note Vault Nova Services, Inc. I Robertson's Ranch, Montecito I Monday, Jan 30, 2017 I Page 2 of 4 02:55 PM Robert VanderPol, II Inspected reinforcing installation in the shower rooms, which is the east finger of the north wing of the recreation building. Checked size, grades, spacing, laps, bar counts, tendon counts, tendon profiles, hold down sizes & embedments per plans and PT shops. All noted problems corrected. Clearances and cleanliness to be checked at time of casting. Etivista and TBP were informed. 02:56 PM Robert VanderPol, II Began preparing stressing paperwork for building #11. TESTS PERFORMED ON-SITE 02:56 PM Robert VanderPol, II No tests. Powered By NoteVault Nova Services, Inc. I Robertson's Ranch, Montecito I Monday, Jan 30, 20171 Page 3 of 4 COMPLIANCE 02:56 PM Robert VanderPol, 11 Performance of today's inspections complied with approved documents. Reinforcing installation in building 11 complies. Reinforcing installation in east finger of north wing, recreation building complies. TIME DEPARTED 03:23 PM Robert VanderPol, II 1530 Powered By Note Vault Nova Services, Inc. I Robertson's Ranch, Montecito I Monday, Jan 30, 2017 I Page 4 of 4 ( •