Loading...
HomeMy WebLinkAbout2523 NAVARRA DR; ; CBR2020-0071; PermitBuilding Permit Finaled Print Date: 07/15/2020 Job Address: Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: 2523 NAVARRA DR, BLDG-Residential 2161702007 $30,000.00 Residential Permit CARLSBAD, CA 92009-7094 Work Class: Track#: Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Deck {city of Carlsbad Permit No: CBR2020-0071 Status: Applied: Issued: Fina led Close Out: Inspector: Final Inspection: Closed· Fina led 01/09/2020 05/30/2020 PBurn 07/15/2020 Description: MATCHPLAY@ LA COSTA: REPLACE IN KIND BEAM ON 3RD LEVEL WALKWAY OF DECK// REPLACING ROTTEN WOOD ON HAN RAILS & DECK TRIM FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL Total Fees: $478.50 Total Payments To Date: $478.50 Balance Due: AMOUNT $278.00 $194.60 $2.00 $3.90 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov ( Cicyof Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 JobAddress ct5d-3 Navarra tir: Suite: /)o'a,._ Plan CheckQ3)9,..;?(b¥') • 00?1:/ Est. Value :A>30l O<Y) - PC Deposit -------- Date _,_I _-_9J....-....:c2=0..,_ __ APN: a//o ?Ol 00 7 CT/Project#: _________________ Lot#: ___ _ Fire Sprinklers: yes/ no Air Conditioning: yes/ no Electrical Panel Upgrade: yes/ no BRIEF DESCRIPTION OF WORK: .i.;~""'!Cl'-'lc:::A;C.e,.!.>&.___.,,_JN:i-.<:i,:._:::,M..~d,.__---"·By_,,,,..:,..""'--c.::.:::'---"'pf\:....,..._/d=."'-'-\'-"\:._::..,WA=:;z/"--_,sgi:.--___ _ ------nt--LI\A.. 0 Addition/New: _____ Living SF, ____ Deck SF, ____ Patio SF, ____ Garage SF Is this to create an Accessory Dwelling Unit? Yes/ No New Fireplace? Yes/ No, if yes how many? __ D Remodel: _____ SF of affected area Is the area a conversion or change of use? Yes/ No 0 Pool/Spa: ____ SF Additional Gas or Electrical Features? ____________ _ □ Solar: ___ KW, ___ Modules, Mounted: Roof/ Ground, Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No Panel Upgrade: Yes/ No D Reroof: ___________________________________ _ D Plumbing/Mechanical/Electrical Only: ________________________ _ D Other: ____________________________________ _ APPLICANT (PRIMARY CONTACT) Name: ~ ~'+--- Address: l';},U ;c,;;c;;_: 1,A,):P, v City: 1/,5½\ State: CA Zii: 9,2oBI Phone: {v~~) S,/4, · ;)6J{pL Email: ,L i'..u-r-t: <§... Pro-ke... .~ I DESIGN PROFESSIONAL Name: _________________ _ Address: _______________ _ City: ________ State: ___ Zip: ____ _ Phone: _________________ _ Email: ________________ _ Architect State License: ___________ _ State License: f. ·'il03 I/ 35 <:!.->°3 C3(, Bus. License: 'BLO,'.l l,l3':lle89 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov C < P~n,:, 1 r,f? R,:,u ORl1A. ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury Qfil!. of the fol/awing declarations: f6' I have and will maintain a certificate of consent to self-Insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. · af1 have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the peJf~rll)ance of the "tork for which this permit is issued. My workers' compensation Insurance carrier and policy number are: Insurance Comp7ny Name: (/fl /+Ed S {)e4-1 A.\o/ I N~C4. (_i, Polley No. ATN-'S.f ,92yro Expiration Date: '5//o 2.t>Lu dcertificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage ls unlawful, and shall subject an employer to crlmlnal penalties and clvll fines up to $100,000.00, In addition e cost of compensation, damaaes as provided for in Section 3706 of the Labor Code, interest and attorney's fees. ( OPTION 8,): OWNER-BUILDER DEQ.ARATION: I hereby affirm that I am exempt from Contractor's License law for the following reason: □ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License La'W does not apply to an owl"!er of property who builds or improves thereon, and who d0es such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner•bullder will have the burden of proving that he did not build or improve for the purpgse of sale). □ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law ·does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). □ I am exempt under Section _______ Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide Portions of the work, but I have hired the following person to coordinate, supervise and provide the major Work (Include name/ address/ phone/ contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): OWNER SIGNATURE: _________________ □AGENT DATE: _____ _ CONSTRUCTION LENDING AGENCY. IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Clvll Code). Lender's Name: ____________________ Lender's Address: ___________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future bulldlng occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 2SS34 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No ls the facllity to be constructed within 1,000feet of the outer boundary of a school site? □ Yes □ No IF ANY OF THE ANSWERS ARE YfS, A FINAL CERTIFICATE Of OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above Information Is correct and that the Information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of cartsbad to enter upon the above mentioned property for Inspection purposes. I Al50 AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE cnv OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS ANO EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID crrv IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA pennit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of ch permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 da •. 4 Uniform Building Code). APPLICANT SIGNATURE: -n"t--'---"'"""?""-------------DATE: ___,/J,,_fj_~_._0_6_£?_~ __ _ I 1635 Faraday Ave Carlsbad, CA 92008 B-1 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of 2 Email: Building@carlsbadca.gov Rev. 06/18 Building Permit Inspection History Finaled {city of Carlsbad PERMIT INSPECTION HISTORY for (CBR2020-0071) Permit Type: BLDG-Residential Application Date: 01/09/2020 Owner: MATCHPLAY AT LA COSTA HOA Work Class: Deck Issue Date: 05/30/2020 Subdivision: Status: Closed -Finaled Expiration Date: 01/05/2021 Address: 2523 NAVARRA DR IVR Number: 24178 CARLSBAD, CA 92009-7094 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 06/26/2020 06126/2020 BLDG-12 Stael/Bond 131237-2020 Failed Paul Burnette Relnspectlon Incomplete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency No 07/09/2020 07/09/2020 BLDG-12 Stael/Bond 132223-2020 Passed Chris Renfro Complete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency Deck repair of beams, stair stringers, and Yes deck joists BLDG-Final Inspection 132224-2020 Failed Chris Renfro Relnspectlon Incomplete Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-Plumbing Final No BLDG-Mechanical Final No BLDG-Structural Final No BLDG-Electrical Final No 07/1512020 07/1512020 BLDG-Final Inspection 132795-2020 Passed Chris Renfro Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready Yes BLDG-Plumbing Final No BLDG-Mechanical Final No BLDG-Structural Final Yes BLDG-Electrical Final Yes Wednesday, July 15, 2020 Page 1 of 1 DATE: May 20, 2020 JURISDICTION: Carlsbad PLAN CHECK#.: 2020-0071 ✓• EsG1I A SAJ Lb1,,ilt Cornpny SET: II PROJECT ADDRESS: 2523 Navarra Dr. PROJECT NAME: Deck Repair for Carolyn Whaley i APPLICANT r JURIS. ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacte~ I Telephone#: Date contacted;..)1<70J-28(b£YJ1 Email: Mail Telephone 0 REMARKS: By: Abe Doliente EsGil Fax In Person Enclosures: 5/12/20 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 .. .. DATE: February 10, 2020 JURISDICTION: Carlsbad PLAN CHECK#.: 2020-0071 ✓• EsG1I A SAH'.bwi!t Cornpany SET: I PROJECT ADDRESS: 2523 Navarra Dr. PROJECT NAME: Deck Repair for Carolyn Whaley ------------·---------. □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. C8:J The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. cgJ The applicant's copy of the check list has been sent to: Les Perry D EsGil staff did not advise the applicant that the plan check has been completed. C8:J EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Les Perry Telephone#: 619-416-2661 Date contacted: (by: ) Email: LPerry@Protec.com Mail Telephone 0 REMARKS: By: Abe Doliente EsGil Fax In Person Enclosures: 1/13/20 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 .. ◄ Carlsbad 2020-0071 February 10, 2020 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. • Please make all corrections, as requested in the correction list. Submit THREE sets of plans for residential projects. For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring IWQ corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 1. All sheets of plans and the first sheet of the structural calculations must be signed by the licensed engineer or architect. (California Business and Professions Code). 2. Balconies and decks shall be designed for 150% of the live load required by Table 1607.1. CBC Table 1607.1, as amended by emergency building standards. Revised the structural calculations using the live load for the deck as 60 PSF. 3. Enclosed framing in wood exterior balconies and decks shall be provided with openings that provide a net free cross ventilation area not less than 1 /150 of the area of each separate space. CBC Section 2304.12.2.6, as amended by emergency building standards. 4. Wood balconies and decks that support moisture-permeable floors shall be provided with an impervious moisture barrier system under the moisture-permeable floor, with positive drainage. CBC Section 2304.12.2.5, as amended by emergency building standards. 5. Specify on the plans the following information for the deck/balcony surfacing materials, per Section R106.1.1: a) Manufacturer's name and product name/number. b) ICC approval number, or equal. Carlsbad 2020-0071 February 10, 2020 The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Abe Doliente at Esgil. Thank you. Carlsbad 2020-0071 February 10, 2020 [DD NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Abe Doliente BUILDING ADDRESS: 2523 Navarra Dr. BUILDING OCCUPANCY: BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Deck Repair Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance 1997 use Building Permit Fee .. ,,.. i 1997 UBC Plan Check Fee . ,;;: ! Type of Review: Complete Review □ Repetitive Fee ,,.. Repeats Comments: D Other 0 Hourly EsGII F- PLAN CHECK#.: 2020-0071 DATE: February 10, 2020 Reg. VALUE ($) Mod. I □ Structural Only 1--------11 Hr. @ • 30,000 I $181.021 Sheet 1 of 1 • August 15, 2019 Ms. KATHY STAHL, Account Manager Match Play at La Costa HOA VIA EMAIL: kath.stahl@gmail.com Subject: Project No. 0805119 Limited Structural Performance Assessment -Deck Beams Existing Residential Building 2523 Navarra Drive, Carlsbad CA DEAR Ms. STAHL: In accordance with your request. we hove performed a limited structural inspection of the subject property. The purpose of the inspection is to visually assess performance of several deck beams on the second floor of the subject building. These beams provide support for an exterior deck/balcony that provides access to the occupants of the residential units within the building. It is our understanding that these beams have been damaged from exposure to on excessive amount of moisture. In order to accomplish this purpose, the undersigned visited the property on August 1, 2019. Soil samples and/or sub-surface explorations were not performed. The focus of our inspection is limited only to a visual observation of the problems and/or concerns discussed above. This report is a confidential report intended solely for the use of the client named above. Any unauthorized use of this report is strictly prohibited. FOLLOWING IS THE RESULT OF THE SITE INSPECTION: GENERAL: l. Subject building is a three-story building, with a wooden framed structure and stucco siding. Building's foundation is slab-on-grade construction. The origina l dwelling was constructed approximately in year 2008. For the purposes of this report we assumed the building faces north (main entry is on the northerly side). 2. Our client represents the current homeowners' association for this property. The purpose of the inspection is to visually assess performance of several deck beams on the second floor of the subject building. These beams provide support for an exterior deck/balcony that provides access to the occupants of the residential units within the building. It is our understanding that these beams have been damaged from exposure to an excessive amount of moisture. 3. Subject beams are located on the second floor of the northerly side for the structure. They provide support to the decking of the third floor. Our clients are mainly concerned about one deck beam that extends in the east-west direction, spanning approximately 14 feet. This beam is labeled as DB 1 on the attached 1930 Watson Way, Suite A, Vista, CA 92081 Phone 760-599-8566 Fax 760-599-8901 Page l > 1--0 partial pion of deck framing. We also analyzed the deck joists as well as two other beams that show indications of moisture damage. These beams ore labeled as DB and DB2 on the attached plan view of the deck framing. SITE INSPECTION: 4. Please refer to the attached sketch view of the residence pion for more details and/or reference. 5. We analyzed the subject deck beams to identify how much of their capacities were being utilized and if any capacity was left over. Please see the attached analysis. Results of the analysis indicates that the deck joists, deck beams DB and DB2 have much more capacity than being utilized (approximately 20% of each member is being utilized by the current loading condition). This implies that each of these beams can be decayed and damaged with more than 50% of their capacity lost and they will still be able to support the decking. The left-over capacity for the deck beam DB 1 is approximately 28% with more than 70% of its' capacity utilized by supporting the decking. 6. The amount of damage observed on the subject decking does not appear to exceed more than 10% to 20% on any of the observed deck beams and/or the deck joists. Largest amount of decay is observed at the main deck beam DB 1. 7. The decking lacks adequate protection against moisture. Decks ot this type are normally protected against moisture by applying a tight and moisture proofed surface. CONCLUSION & RECOMEMNDATIONS: A. The observed decking lacks adequate moisture protection system and is subject to further damage and/or decay. We recommend our clients consider modifying the decking system to add protection against moisture intrusion. B. The amount of observed damage in majority of the decking's structural members is acceptable at this time with the exception of deck beam DB 1 . The amount of decay observed within deck beam DB 1 is reaching the level close to requiring replacement. We recommend our clients consider replacing this beam with a new, like for like. C. Care shall be taken in making the improvements to insure its effectiveness. We strongly recommend that our clients retain our services to provide consultations to the contractor, and to inspect the repair work (this service is not included within the scope of work for this report). Conditions may arise during the repair work that are different from these presented, and supplemental recommendations may be presented. An engineer's certificate will be issued once we are satisfied improvements have been substantially completed in accordance with our recommendations. D. Soil samples and/or sub-surface explorations were not performed. It should be kept in 1930 Watson Woy, Suite A, Vista, CA 92081 Phone 760-599-8566 Fax. 760-599-8901 Page 2 .L ~ Private Eyes Engineers mind that the on-site evaluation conducted was limited to a visual review of conditions. As such, our comments are primarily based on the limited data collected, experience with similar projects, and professional judgment. UNCERTAINTY AND LIMITATIONS: The conclusions and recommendations presented herein ore based on visual observations, results of document research and the results from the limited borings, if any. No subsurface investigation was made, and this inspection is not what might be referred to as "soils report". We can make no determination of the prior grading activity without more extensive research of public records or subsurface investigation. The discoveries of any latent soils/geologic defects, which may occur or arise at some future date, are beyond the purpose and intent of our investigation. We have made no evaluation of the superstructure or the electrical and mechanical systems that are part of this property. We have not performed any analysis of the lateral stability of the structure against seismic forces. These services are available at an added fee. The professional judgments and opinions presented herein are based partly on an evaluation of the information gathered, and partly on our experience in the structural field. The structural work and judgments rendered meet current professional standards and no warranties are expressed or implied. Standards of practice are subject to change with time. Recommendations presented are based on the scope of work performed; they are professional opinions that are limited to the extent of the available data. This is not a structural pest control inspection. A separate inspection report, normally by a pest control company, addresses the presence or absence of wood destroying organisms. We do not guarantee the work of the developer, contractors, or other consultants that may have performed work at the site. Therefore, no guarantees or warranty of any kind is expressed or implied pertaining to the future performance of the site or the structure thereon in any respect. While some references to hazardous materials and code compliance may be made, our report is not a complete investigation for code compliance or public records that might affect this property. This inspection report was not prepared to be used as fulfillment of the disclosure requirements of California Civil Code Section 1102.6, nor is it to be used as substitute disclosure as a uthorized by section l l 02.4. If you have any questions, or if we can be of further assistance, please call our office . Respectfully Submitted, ~ µ() t!/1 >111 Massood Gaskari, P .E. 1930 Watson Way, Suite A, Vista, CA 92081 Phone 760-599-8566 Fox 760-599-8901 Page3 Bl:!rivate Eyes En I t 6): ◄- 2-·- 2-. 3 STORY RESIDENTIAL BUILDING 6"x6"Posts from / above floor - 0 0 -N il1 @J ID ~ 'ii' • ...J ,:, 2 "X Ledger (Typ.) -. -,) i-·-·--c \ -·-·-t'.I 12"x12" Post5(Typ,) ~ DECK BEAMS ARE DECAYED (2) ON SECOND FLOOR. PARTIAL DECK FRAMING PLAN UNIT# 200 MS. KATHY STAHL -THE MATCH PLAY HOA SHEET: --1 1 · ::~::::::.-: -~::~~ __ _::I ~~EN: ... -:--·-·-------i --·-C~rlsbad~~- 92 ~~ ----------~MeNs~or-f;~APPROXIMATEl ____ --···· _ __ _ ___ .. _ -· J 1930 Watson Way, Suite A, VISTA, CA. 92081 Phone (760) 599 -8566 Fax (760) 599-8901 ' I I I I i I I I I I I I 7) / .,t,/ L -:: / 7,.f 1 ~ 1930 Watson Way, suite A, Vista, CA 92081 v.J ! <.,1 I)-/, Vi?, /?!/ 330 Phone (760) 599-8566 Fax (760) 599-8901 C PEf Private Eyes Engineers 0 /;yj5f "tf 5: f->(!....;-z I I, \'-, -0 5' (Jo. V"' .';-g'_o ,._ 0/L~~ 2 '( p.c) . _ 2"(Ltu) /'(?'" r Jo ' vi?:, I ./~~ .. :: 80 1930 Watson Way, suite A. Vista, CA 92081 Phone (760) 599-8566 Jlf~O ✓, r:?L ~ f;--i ~ ;,d VettP t:J-¾ ,,)(6 A) Fax (760) 599-8901 - CIVIL ENGINEERING DESIGN GROUP 2420 GRAND AVE. SUITE B-1 Project Title: Engineer: Project ID: Project Descr: Printed: 8 AUG 2019, 2:55PM -Fl_!d _= C-~-Js-e~-'roo-re-~,20fYJd ;Wood Beam hi ENERCA.Lf. INC 1!183-2018. Build 10 16 t21; Description : DJ-existing deck Jolsts--0805119-2523 Navarra Or. · CODE REFERENCES ... •· -. --····-·-·-.. ,. -......... _ ·----- Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: IBC 2018 Material Properties • I • Analysis Method : Allowable Stress Design Load Combination IBC 2018 Fb+ 900psi E : Modulus of Elasticity Fb-900psi Ebend-xx 1600ksi Fe· Prll 1350psi Eminbend • xx 580ksi Wood Species : Douglas Fir -Larch Wood Grade : No.2 Beam Bracing : Completely Unbraced Fe -Perp 625psi Fv 180psi Ft 575psi Density 31.21pcf f D{0.01) L(0.08) ♦ ,. r ·--------~E---------7 I I V 4x8 4x8 Span= 7.50 ft Span= 2.0 ft Applied Lo~ds . . .. _ -· _ . Service loads entered. Load Factors will be applied for calculallons. Beam self weight calculated and added to loads Load for Span Number 1 Uniform Load: D = 0.010, L = 0.080, Tributary Width = 1.0 ft, (1) Load for Span Number 2 Uniform Load : D = 0.010, L = 0.080 , Tributary Width = 1.0 ft, (1) .. Q~$IG/V_$J.!.M!rMRY .... -.... _. ____ --·-· ... .. ------..... ·-·-·-----·--··-·- 1Maximum Bending Stress Ratio 0.196 1 Maximum Shear Stress Ratio Section used for this span 4x8 Section used for this span lb: Actual = 226.75psi fv : Actual FB : Allowable 1, 158.48psl Fv : Allowable Load Combination +D+L Load Combination Location of maximum on span = 3.478ft Location of maximum on span Span # where maximum occurs = Span # 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection I _ 0.027 in Ratio = -0.018 in Ratio= 0.032 in Ratio = -0.021 in Ratio= Maximum Forces & Stresses for Load Combinations .. ' -. -. ---'-·· .. . . . . -. Load Combination Max Stress Ratios 3354>=360 2664>=360 2809>==240 2232>=240 Moment Values = :: ~sign OJ{ 0.108 : 1 4x8 19.36 psi 180.00 psi +D+l 6.913 ft Span# 1 ··---~-----Shear Values Span# Cd CFN C 1 Cr -----·--Segment Length M V Cm Ct CL M fl> F'b V fv F'v ----·------·---------·---D Only 0.00 0.00 0.00 0.00 Length = 7 .50 ft 1 0.035 0.019 0.90 1.300 1.00 1.00 1.00 1.00 0.99 0.09 36.80 1043.82 0.05 3.14 162.00 Length = 2.0 ft 2 0.012 0.019 0.90 1.300 1.00 1.00 1.00 1.00 1.00 0.03 12.13 1050.57 0.02 3.14 162.00 -+O+L 1.300 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 7 .50 ft 1 0.196 0.108 1.00 1.300 . 1.00 .1.00 1.00 1.00 0.99 0.58 226.75 1158.48 0.33 19.36 180.00 Length = 2.0 ft 2 0.064 0.108 1.00 1.300 1.00 1.00 1.00 1.00 1.00 0.19 74.75 1166.99 0.13 19.36 180.00 -+0+0.750L 1.300 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 CIVIL ENGINEERING DESIGN GROUP 2420 GRAND AVE. SUITE 8-1 jWood Beam I I. 11 Description : DJ..exalng deck Jolsts-0805119-2523 Navarra Dr. Load Combination Max Stress Ratios Segment Length Span# M V -----------:-:-:-:----:-:-= Length= 7.50 ft 1 0.124 0.068 Cd CFN 1.25 1.300 Length = 2.0 ft 2 0.041 0.088 1.25 1.300 +0.60D 1.300 Length = 7.50 ft 0.012 0.007 1.60 1.300 Length = 2.0 ft 2 0.004 0.007 1.60 1.300 Overafl Maximum Deflections Project Title: Engineer: Project ID: Project Descr: C1 Cr Cm Ct Cl 1.00 1.00 1.00 1.00 0.99 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.98 1.00 1.00 1.00 1.00 1.00 Load Combilatlon Span Max.•.• Defl Location in Span Load Combination +D+l Vertical Reactions Load Combination 1 2 0.0320 0.0000 Support 1 3.687 3.687 +D+l Support notation : Far left Is #1 Support2 Support3 Overall MAXlmum ·-··-----------....r----.~.-----0.333 0.575 Overall MINimum 0.279 0.481 DOnly 0.054 0.093 +D+l 0.333 0.575 +D+0.750L 0.263 0.454 -+0.60D 0.032 0,056 L Only 0.279 0.481 Printed: 8 AUG 2019, 2:55PM F,e,. r. \Useis'rocre~'GOC.21.119.ec6 Sa.-.ftw2r'l ropynglit ENERC;,\L(", INC 19BJ-;20i? 8'Jlld 'iO 1 ~ 12 i3 .. ;. . Moment Values Shear Values M lb Pb V fv F'v -· ·--0.46 179.26 1443.68 0.26 15.31 225.00 0.15 59.10 1457.74 0.11 15.31 225.00 0.00 0.00 0.00 0.00 0.06 22.08 183911 0.03 1.89 288.00 0.02 7.28 1864.07 0.01 1.89 288.00 Max.'•' Dell Location In Span 0.0000 0.000 -0.0215 2.000 Values in KIPS CIVIL ENGINEERING DESIGN GROUP 2420 GRAND AVE. SUITE B 1 Project Title: Engineer: Project ID: Project Descr: !Wood Beam Printed: 13 AUG 2019, 9:49AM -·-·· ---· --------·--. ----. 'File-=-,,(-l\)Sffl,--,-"fr,orey\(ll)skiop\C.SC201Rec.6 S,,f!ware copynghi ENER(-ALC. INC 1983-2018, Build ft111! n 1~ I > • •• Description: DB-exiSUng aec~ beam-0805119-2523 Navarra Dr. CODE REFERENCES . -. -··-........ - Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: IBC 2018 ------·--·-·-------·, - Material Properties ____ _ Analysis Method : Allowable Stress Design Fb + 1,000.0psi E : Modulus of Elasticity Load Combination !BC 2018 Fb -1,000.0psi Ebend-xx 1,700.0 ksi Fe -Prll 1,500.0 psi Eminbend -xx 620.0 ksi Wood Species : Douglas Fir -Larch Fe -Perp 625.0 psi Wood Grade : No.1 Fv 180.0psl Fl 675.0psi Density 31.21 Opcf Beam Bracing : Completely Unbraced D(0.041l L(0.33) v ~ • ---··-·-------- 6x14 r-Span= 10.0ft Ap_plled Loads Service loads entered. Load Factors wm be applied for calculations. Beam self weight calculated and added to loads Uniform Load : D = 0.0410, L = 0.330 , Tributary Width= 1.0 ft, (1) DESIGN_ ~Y.MMA~Y : Maximum Bending Stress Ratio ' Section used for this span fb: Actual FB : Allowable Load Combination Location of maximum oo span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection = 0.350 1 6x14 347.56psi 991.89psi +D+L Maximum Shear Stress Ratio Section used for this span fv : Actual 5.000ft Span# 1 0.039 In Ratio= 0.000 in Ratio = 0.046 in Ratio= 0.000 in Ratio= Fv : Allowable Load Combination Location of maximum on span Span # where maximum occurs 3080>=360 0<360 2625>=240 0<240 = Maximum Forces & Stresses for Load Combinations . -' ·---·---Load Combinatlon Max Stress Ratios MomenlValues ------Cd CFN C1 Cr Cm CI CL ·--Segment Length Span# M V M lb F'b -----·---··-DOnly 0.00 Length = 10.0 ft 0.057 0.028 0.90 0.987 1.00 1.00 1.00 1.00 0.99 0.71 51.26 893.53 -+04. 0.987 1.00 1.00 1.00 1.00 0.99 0.00 Length = 10.0 fl 0.350 0.170 1.00 0.987 1.00 1.00 1.00 1.00 0.99 4.84 347.56 991.89 -+0->-0.750l 0.987 1.00 1.00 1.00 1.00 0.99 0.00 Leng1h = 10.0ft 0.221 0.107 1.25 0.987 1.00 1.00 1.00 1.00 0.99 3.81 273.48 1236.87 ·+-0.600 0.987 1.00 1.00 1.00 1.00 0.99 0.00 LenQth = 10.0 fl 0.019 0.009 1.60 0.987 1.00 1.00 1.00 1.00 0.99 0.43 30.76 15TT.32 OeslgnDK-.. V 0.00 0.22 0.00 1.51 0.00 1.19 0.00 0.13 0.170 : 1 6x14 30.54psi 180.00 psi +O+L 0.000ft Span# 1 Shear Values tv 0.00 --F'v 0.00 4.50 162.00 0.00 0.00 30.54 180.00 0.00 0.00 24.03 225.00 0.00 0.00 2.70 288.00 CIVIL ENGINEERING DESIGN GROUP 2420 GRAND AVE. SUITE B-1 i W~~dBeam Project Title: Engineer: Project ID: Project Descr: Description : DB-exlSting deck beam-0805119-2523 Navarra Dr, Overall Maximum Deflections Load Comlllna1ion Span -+O+L ------1 - Vertical Reactions Load Combination Max.·-• Dell 0.0457 Locafion In Span Load Combilation ~---- Support notation: Far left is #1 Support 1 Support 2 Overall wJ<rmum ·-· .... ____ 'l']Js"" ~1.=93=5--·----··-- Overall MINimum 1.650 1.650 D Only 0.285 0.285 -+04. 1.935 1.935 +D-+0.750L 1.523 1.523 +0.600 0.171 0.171 L Only 1.650 1.650 Prtme<l: 13 AUG 2019, 9:49AM Fde= (. \t.b8!S!.ioole)'IOt-slo.~~1S ecc ~'t'l2!11-. /fl .tENERCALC. IHC 19f!3.2fl18, Gudd 111181213 Max.'+' Defl 0.0000 Values in KIPS . . . . . Location in Span 0.000 CIVIL ENGINEERING DESIGN GROUP 2420 GRAND AVE. SUITE 8-1 Project Title: Engineer: Project ID: Project Descr: ,-·-----------·----------·-···----· --------Printed· 12AUG2019, 10:14AM ~::,-·11e-"-c(,-ccil..ls«$-:--:--lnlOl-ev\[)eo;ktopl(,B(,20fll ..:6 1 Wood Beam Scftware c ht 1:NERCAlC. INC 1983-201R. Butk:f-!u 18121.l Description : D81-exlsting deck beam--08051 19-2523 Navarra Dr. CODE REFERENCES Calculations per NOS 2018, !BC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2018 __ Mater~al Properties Analysis Method : Allowable Stress Design Load Combination 1BC 2018 Fb + Fb - 1000psi 1000psi 1500 psi E: Modulus of Elasticity Wood Species : Douglas Fir -Larch Wood Grade : No.1 Beam Bracing : Completely Unbraced -... --D(D.6) r67) J: ___ _ '~" App_lied _ L~a~s . _ . Beam self weight calculated and added to loads Fe -Prll Fe -Perp Fv Ft 625psi 180psi 675psi Ebend-xx 1700ksi Eminbend -xx 620ksi Density 31 .21 pct 0(0.6) c•(D.67) • D(0.095J L(0.24) ~ ; ------·---1 i 6x14 ·t!> A -. Span= 14.0 ft Service loads entered. Load Factors will be applied for calculatlons. Uniform Load : D = 0.0950, L = 0.240 , Tributary Width= 1.0 ft, (1) Point Load : D = 0.60, Lr= 0.670 k @ 2.0 ft, (2) Point Load : D = 0.60, Lr= 0.670 k@ 12.0 ft, (2) _ DESIGN SUMMARY .... __ ··---·· .... Maximum Bending Stress Ratio · Section used for this span fb: Actual FB : Allowable Load Combination Location of maximum on span Span # where maximum occurs Maxlmum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection = . -----0.712 1 6x14 704.06psi 988.67psi +D+L Maximum Shear Stress Ratio 7.000ft Span# 1 0.109 in Ratio= 0.000 in Ratio = 0.185 in Ratio = 0.000 in Ratio= Section used for this span fv : Actual Fv : Allowable Load Combination Location of maximum on span Span # where maximum occurs 1543>=360 0<360 907>=240 0<240 = = = Maximum Forces & Stresses for Load Combinations ---. ·----.. -··-·--Load Combilation Max Stress Ratios Moment Values Segment Leng1h Span# M V Cd CFN c, Cr Cm CI Cl M --fb--F'b ·----· DOnly 0.987 1.00 1.00 1.00 1.00 0.98 0.00 Length = 14.0 ft 0.316 0.156 0.90 0.987 1.00 1.00 1.00 1.00 0.99 3.92 281.70 891.00 -+0-+L 0.987 1.00 1.00 1.00 1.00 0.99 0.00 Length = 14.0 ft 1 0.712 0299 1.00 0.987 1.00 1.00 1.00 1.00 0.99 9.80 704,06 988.67 -+O+lr 0.987 1.00 1.00 1.00 1.00 0.99 0.00 Length = 14.0 ft 0.307 0.173 1.25 0.987 1.00 1.00 1.00 1.00 0.99 5.26 377.95 1231 .38 +D+O. 750!.r-i-O. ?SOL 0.987 1.00 1.00 1.00 1.00 0.99 0.00 Length" 14.0 ft 1 0.545 0.253 1.25 0.987 1.00 1.00 1.00 1.00 0.99 9.34 670.65 1231.38 0.299: 1 6x14 53.80 psi 180.00 psi +D+L 12.876ft Span# 1 Shear Values ---V fv Pv -------·-0.00 0.00 0.00 1.25 25.31 162,00 0.00 0.00 0,00 2.66 53.80 180.00 0.00 0.00 0.00 1.92 38.84 225.00 0.00 0.00 0,00 2.81 56.83 225.00 - CIVIL ENGINEERING DESIGN GROUP 2420 GRAND AVE. SUITE 8-1 I .. ··-----·-W00d Beam Description : D81-ex,sting deck beam-0805119-2523 Navarra Dr. Load Combination Segmen1 Length -0+0.750L Length = 14.0 ft -+0.60D Span# Max Stress Rafus . - M V 0.527 0225 Lenglh = 14.0 II 1 0.108 0.053 Overall Maximum Deflections Cd CFN 0.987 1.15 0.987 0.987 1.60 0.987 Project Title: Engineer: Project ID: Project Descr: Ci Cr Cm C t CL 1.00 1.00 1.00 1.00 0.99 1.00 1.00 1.00 1.00 0.99 1.00 1.00 1.00 1.00 0.99 1.00 1.00 1.00 1.00 0.98 Load Combination Span Max.•-· Defl Location i1 Span Load Combination -O+L Vertlcal Reactions Load Combilation OVeraf! MAXimum Overall M1Nimum D Only ..0-tl ..0-tLr -+D-+-0. 750Lr-+O. 750L -+0-+0.750L -+0.60D Lr Only L Only ---1----o-:1as-2--7.051 --- Support 1 3140 1.680 1.378 3,058 2.048 3.140 2.638 0.827 0.670 1.680 Support notation : Far left Is #1 Support2 3.140 ------- 1.680 1.378 3.058 2.048 3.140 2.638 0.827 0.670 1,680 Printed: 12 AUG 2019, 10:14AM ---··--F-,ltl-=_C_\User_s\moi-e,-ibes~½o19.cc5 ~ nglr. !:NER•AC; fNC 1983-201B. Buld 1018 12.13 • I - Moment Values Shear Values M fb Pb V fv Pv -----------0.00 0.00 0.00 0.00 8.33 598.47 1134.56 2.31 46.68 207.00 0.00 0.00 0.00 0.00 2.35 169.02 1567.14 0.75 15.19 288.00 Max.'+' Defl 0.0000 Values In KIPS Location In Span 0.000 CIVIL ENGINEERING DESIGN GROUP 2420 GRAND AVE. SUITE B-1 Project Title: Engineer: Project ID: Project Descr: ,----------·---··---l Wood Beam )i .. Printed: 13 AUG 2019, 9:50AM F,1e-;;i·-~~Bi.;2019.~ - So.'tw,n>cooynqhl ENERCAu. IN( 1933-2018. Builrl 101812 13 Description : 0B2-exlstmg aecJI oeam-O!l<)5119-2:i:D Navarra Or. CODE REFERENCES .... -. . --· ...... -. Calculations per NOS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2018 Material Properties • --• I Analysis Method : Allowable Stress Design Load Combination !BC 2018 Fb + 1,000.0psi 1,000.0psi 1,500.0 psi E : Modulus of Elasticity Wood Species : Douglas Fir -Larch Wood Grade : No. 1 Beam Bracing : Completely Unbraced Fb - Fc-Pr!I Fe • Perp Fv Ft 625.0 psi 180.0psi 675.0 psi Ebend-xx 1,700.0ksi Eminbend -xx 620.0ksi Density 31.210pcf D(0.29) 1 U1.65J ~---+:--~-----=D(->-=0=.00=...;.,1)~L=(0=.0=8;;.L) ___ ~, . ·-------, r-6x14 Span= 8.0 tt. ~pplied_ Lo~ds_ . . Service loads entered. Load Factors will be applied for calculations . Beam self weight calculated and added to loads Uniform Load : D = 0.0010, L = 0.080, Tributary Width= 1.0 ft, (1) Point Load : D = 0290, L = 1.650 k@ 1.0 ft, (2) DESIGN SUMMARY r --------------. ----.... ·---·---Maximum Bending Stress Ratio Section used for this gpan fb : Actual FB : Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflectlon = .. 0.148 1 6x14 147.22psi 993.39psi +D+l Maximum Shear Stress Ratio Section used for this span fv : Actual 1.489ft Span# 1 0.010 in Ratio= 0.000 In Ratlo = 0.012 in Ratio = 0.000 in Ratio= Fv : Allowable Load ComblnaUon Location of maximum on span Span # where maximum occurs 9773>=360 0<360 8209>=240 0 <240 Maximum Forces & Stresses for Load Combinations ------Load Combination Max Stress Ratios Moment Values -Cd CFN Ci Cr Cm CL 1b Segment Length Span# M V Ct M ------·-·-·· --· ----·--------· ----DOnly length = 8.0 ft 0.026 0.011 0.90 0987 1.00 1.00 1.00 1.00 0,99 0.32 23.00 -+O+l 0.987 1.00 1.00 1.00 1.00 0.99 Length = 8.0 ft 0.148 0.059 1.00 0.987 1.00 1.00 1.00 1.00 0.99 2.05 147.22 +0-+0. 750L 0.987 1.00 1.00 1.00 1.00 0,99 Length = 8.0 ft 0.094 0.037 1.25 0.987 1.00 1.00 1.00 1.00 0.99 1.62 116.14 -+-0.60D 0.987 1.00 1.00 1.00 1.00 0.99 Length = 8.0 ft 0.009 0.004 1.60 0.987 1.00 1.00 1.00 1.00 0.99 0.19 13.80 F'b 0.00 894.71 0.00 993.39 0.00 1239.37 0.00 1581.82 llesl{jriO __ . 0.059 : 1 6x14 10.57 psi 180.00 psi -+D+L 6.891 ft Span# 1 ·-----Shear Values --·---·--·---V fv F'v ----·-· 0.00 0.00 0.00 0.09 1.73 162.00 0.00 0.00 0.00 0.52 10.57 180.00 0.00 0.00 0.00 0.41 8.36 225,00 0.00 0.00 0,00 0.05 1.04 288.00 CIVIL ENGINEERING DESIGN GROUP 2420 GRAND AVE. SUITE B-1 • r-··-~-----·-·· ------------·---------Wood Beam Description : 002-exlsfing deck beam--0805119-2!)23 Navarra Or. Overall Maximum Deflecttons Load Combination Span +D+l Max. • .• Deft Location in Span 0.0117 3.679 Project Title: Engineer: Project ID: Project Descr: Load Combination Vertical Reactions Load Combioatkll1· Support notation : Far left is #1 "'"Overall MAXimum Overall MIN!mum D Only +D-+l -0+0.750L +0.60D LOnly Support 1 2.086 1.764 0.322 2.086 1.645 0.193 1.764 Support2 0.631 0.526 0.105 0.631 0.499 0.063 0.526 Printed: 13 AUG 2019, 9:50AM Hit-= c, l.Usfi~\1110!i!y\[)P.s.lqr.ciiC.2019_;;r- ~;n, r.opynght ENERCAU:. INC 1()8.1-2018 Bllild 101812 !3 • It . • Max. '+' Defl Locatloo in Span 0.0000 0.000 Values in KIPS