Loading...
HomeMy WebLinkAbout2523 STATE ST; ; CB151277; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 10-19-2015 Residential Permit Permit No: CB151277 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: 2523 STATE ST CBAD RESDNTL 2030543439 $329,747.00 1 0 Sub Type: CONDO Lot#: 39 Constuctlon Type: 58 Reference#: CT130005 Structure Type: MF5+ Bathrooms: 0 Status: ISSUED Applied: 04/2~/2015 Entered By: JMA Plan Approved: 10/15/2015 Issued: 10/15/2015 Inspect Area: Project Title: Orig PC#: PC140037 STATE ST. TOWNHOMES: PHS 3 B4B Plan Check#: PC150022 408 SF 1 ST FLR COMMERCIAU1 ,943 SF LIV/ 450 SF GAR/ 88 SF BALCONY/ 731 SF ROOF DECK Applicant: TAYLOR MORRISON OF CA, LLC STE 1450 100 SPECTRUM DR IRVINE CA 92618-4935 949-341-1289 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park In Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee HMP Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee Green Bldg Stands Plan Chk Fee $1,437.96 $0.00 $1,006.57 ($500.00) $0.00 $42.87 $6,190.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $3,931.00 FS1 $0.00 $0.00 $14.00 $0.00 Total Fees: $29,986.93 Total Payments to Date: Owner. Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWA Fee CFO Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) ·Traffic Impact Fee (4305541) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing lnlieu Fee Housing Credit Fee Master Drainage Fee Sewer Fee Addltlonal Fees Fire Sprinkler Fees TOTAL PERMIT FEES $29,986.93 Balance Due: FS1 $0.00 $317.00 $4,800.00 $0.00 $6,001.40 $5,539.75 $0.00 $0.00 $0.00 $0.00 $0.00 $210.00 $89.00 $65.38 $0.00 $0.00 $0.00 $0.00 $842.00 $0.00 $0.00 $29,986.93 $0.00 Date: Clearance: ------ <WM cJ pr rrtjed lrdi.rl3s the , rrµ:st!oo" cJ fees, oo:iailcm, resa"Vcm'lS, Cl" cth3I' €l)0jjcm h:ratta" crl1edl\6}' rdared to as "fees/exa:!lcns. Yi t"0Ye 00 de¥! fran the date ttis r:arrit \'al lssu3d to puest lrrimtiai cJ these fees/ENdla,s. If }O.J ~ th:m, }O.J ITUlt fcioNthe ~ rxoc,ed.res set fath In C:oMmBi Gem 8.edla, OOJ20(a). crd file the ~ ard fET'f drff ra:jlll'OO lr!amiiCtl wth the Qty~ fir ~rg in amda u, v.lth C8rl8ta:J Mllfdpa Gem 8.edlal 3.32.CID. Pcilire to tirrely fdioN trat ~ wll oor BT¥ SLbleqm legal actlcf1 to cilOO<, review, sa aside, \dd, Cl" a-ru trar lllµ)Slticn Yru 8'8 h3rEbJ A.JRfl-ffi t\DTIRB) trat pr rifti to puest the sp3dfioo foos'emlicns CCES !\Of />PPL Y to 'A0!er a"'d -CDlll3dim fees ard ecµrity c:raigas, nCJ" JmTirg, zcrlrg. groorg CJ" drff slnila-~lailc:t1 p-ocesslrg CJ" se!\.100 fees In caT'lidlm wth ttJS IJtjed. N:R CCES IT />PPL Y to ITT/ City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 10-19-2015 Storm Water Pollution Prevention Plan (SWPPP) Permit Permit No:SW150187 Job Address: Penntt Type: 2523 STATE ST CBAD SWPPP Parcel No: 2030543439 Lot#: 0 Reference #: PC150022 CB#: Project Title: STATE STREET TOWNHOMES Applicant: TAYLQR MORRISON OF CALIFORNIA STE 1450 8105 IRVINE CENTER DR IRVINE CA 92618 949 341-1289 Emergency Contact: TOM BAINE 714 920-3525 SWPPP Plan Check SWPPP Inspections Additional Fees TOTAL PERMIT FEES Owner: Status: Applied: Entered By: Issued: Inspect Area: Tler: Priority: ISSUED 04/28/2015 JMA 10/15/2015 PY 1 L $0.00 $58.00 $0.00 $58.00 Total Fees: $58.00 Total Payments To Date: $58.00 Balance Due: FINAL APPROVAL DATE~ifi_EA 'SIGNATURE _ ___.:.:.iA-J--fF-~--- $0.00 Inspection List Pennlt#: CB151277 Type: RESDNTL CONDO STATE ST. TOWNHOMES: PHS 3 848 408 SF 1ST FLR COMMERCIAU1,943 SF L Date Inspection Item lnse_13_ctor Act -------Comments 06/15/2016 89 Final Combo , PY AP 05/19/2016 39 Final Electrical PY AP 03/31/2016 17 Interior Lath/Drywall PY AP 03/30/2016 18 Exterior Lath/Drywall PY AP 03/25/2016 84 Rough Combo PY PA 03/24/2016 84 Rough Combo PY AP 03/08/2016 13 Shear Panels/HD's PY AP 03/07/2016 13 Shear Panels/HD's PY CA 03/07/2016 13 Shear Panels/HD's PY CA 02/24/2016 15 Roof/Re roof PY AP 02/16/2016 17 Interior Lath/Dl)'Vlall PY PA 02/08/2016 15 Roof/Re roof PY AP 01/21/2016 17 Interior Lath/Drywall PY PA 12/01/2015 81 Underground Combo PY AP 11/13/2015 21 Underground/Under Floor PB AP Tuesday, June 21, 2016 Page 1 of 1 . -,- <t~ITY n< CB151277 2523 STATE ST 'CARLSBAD· INSPECTION RECORD ~•Jlkflng Division STATE ST. TOWNHOMES: PHS 3 B4B 408 SF 1 ST FLR COMMERCIAU1 ,943 Sf:; UV/ 450 SF GARI 88 SF BALCONY/ 731 SF ROOF DECK RESDNTL CONDO ' --INSPECTION RECORD CARD WITH APPROVED PLANS MUST-BE KEPT ON THE JOB Lett 39 TAYLOR MORRISON OF CA, LLC @ CALL BEFORE 3;30'PIJI FOR NEXT WORK DAY INSPECTION 0 FOR BUILDING INSPEC:nON CALL:-76o;.;602-2725 OR GO TO: www.Carfsbadca;goy/8U1ldlng AND CUCK ON "Request Inspection· RECORD COPY Required Prior to Requesting Buftdlng Fin11J lf Checked YES Plannlng/landscape CM&I (Engineering lmpoctlons] .~ Arc Prevention lt12 REINFORCED STEEL ~6 MASONRY PRE ORD UT 0 GROUT D WALL DRAINS lflO TILT PANELS I #11 POUR STRIPS lf11 COWMN FOOTINGS f14 SUBFRAME D FlDOR O CEILING #15 ROOF SHEATillNG 113 EXT. SHEAR PANELS ff16 INSULATION #18 EXTERioR LATil #17 INTERIOR LATII & DRYWAll #51 POOL EXCA/S1£E BOND/FENCE #55 PREPI..ASTER/RNAL #22 0 SEWER & BL/CO D PL/CD #21 UNDERGROUND OWASTE O WTR 124 TOPOUT 0.WASTE DWTR #27 rue & SHOWER PAN #23 GAS TEST D GAS PIPING 1#25 WArnl HEATER FOLLOW UP IMSPECllON NOTICE TO CLEAN --u:: #607 WRITTEPI WARIUNG #609 NOTICEOFVIOI.ATION '610 VERBAL WARNING RUV 10/2012 760-944-8463 760-438-3891 7 60-602-4660 Allow 48 hOurs CIIII before 2 pm Allow 48 hours #34 ROUGH ELECIRJC #33 D ELECTRIC SERVICE D TEMPORARY ffl PIIOTOYOLTAIC #39 AHAL , C•1:>.: II MECHANICAL 141 UNDEReROUND DUCTS & PlPJNG 0 DUCT & PLEIIUM O REF. PlPl"O S OVERHEAD HYDROSTATIC A/SFIHAL F/ A ROUGH-IN F/AFJHAl FIXED EXTINOUISIUMO SYSTEM ROUGH-IN FIXED EXTING SYSTEM HYDROSTATIC TEST FIXED EXTINQUISHING SYSTEM ANAL MEDICAL GAS PRESSURE TEST MEDICAL GAS ANAL } Date llispector SEE BACK FOR SPECW. NOTES I . ('city of Carlsbad CIRCUIT CARD 8-36 ~~ Development Services Building Division 1635 Faraday Avenue 76G-602-2719 www.carlsbadca.gov THIS CARD MUST BE FILLED OUT AND AV All.ABLE AT THE SERVICE EO UIPMENT FOR THE ROUGH INSPECTION Address: UZJ 3hl"I! S/'A-e1,r-Pennlt Number. C,1 ISi 1, 11 OWner: 4';i y c., ,< .l-,,1 If. s:.,o.,.J Phone: &v r,,) J\/ /. ano Area In Sq. Ft 2JS7 Contractor: .J} l.n t ...rz.. LA ILi. ,/ ~J r. Phone: - PANEL: I 2.. ~ :A,v\.f 'lo A.LC. -z. -u, VOLTS 0 WIRE LOCATION CKT BKR WIRE MISC REC REC LTG MISC WIRE BKR CKT LOCATION SIZE SIZE TYPE SIZE TYPE SIZE \'---it 4\G-' c'5 1 I~ l'I W#..cl 'f I 65 q II/ 711~µ IS 2 ~af¥ T\t "'4-3 20 ,t If 2 S' q It/ ( ( ff 4 Liv~ ~H--<?111-1 5 '2.0 ,i II 2 Lf · 'f If ({ /5' 6 ~ 1'.-~ 7 'ZO It (/ I (,, R IL/ ,, 11' 8 lw:11~ !~~ 9 . '10 fl If 'I l l 'L l"I If ,~ 10 k~ .~ D«'.I.'" lhll'.c-e 11 10 ll If ( ~ 'l I'( I/ 15 12 ' ftA.._, bt- ~L4-l'IPI 13 "ZO l'l I/ 1 l/ r /l{ II I'S 14 (-!,,..fCIU 0 t /£ _, -~ 15 18 A II I I II./ I/ IS 16 ~ . , Nr 17 'l,o fl // I I lq 'I ,, 18 · t)~A.<- J.vt, 19 1,4!J 12 II I I t'I ,, 15 20 ~4 A1G 21 vr-/0 'I I 22 Nc.-23 /0 I/ I 24 25 26 27 28 29 30 31 32 33 34 35 38 37 38 39 \ 40 41 42 MAIN:D l,cp AMP BRK/FUSE O MLO Computed Load AMPS BUS: ~ AMP Sae CslculstJon Worlraheet on back Branch clrculta required: Service en!nlnce or feeder conductors: A) Lighting Ctrcults 220 -3(b), 4{d) A) Size: No. B) Type: D cu D AL B) Two Small Appllance Circuits 210-11(e) C) Insulation: D) Conduit Size: C) Laundry Clrcult 220-16(b) Serv1ce ground/bond: B) Type: ~u D AL D) Central Heating Equipment 422-12 A) Size: No. i E) Bathroom 210 -52(d) ~Clamp locatf (8): UFER 250-50(c) Remarks: D Wall,r Pipe 250-104 D Ground Rod 250-52 D GFCI locatlons 210-8, 680-70: ~chen I certify that all terminations have been torqued In accordance with manufacturer's ~throom(s) Instructions and that the work shown on this clrcu/t card reprasenta the run extent of erage(e) DHydromassage Tub the work performed under th~ permit. 121:>utd oors D D Owner AFCI Protected Clrc. 210-12 'D Contractor ',,,,< (.; 0"'Badroom(s) D Signed '-d'f...--Date 3-!4.-{~ n 8-36 Page 1 of 2 Rev. 03/09 SINGLE FAMILY DWELLING ELECTRICAL SERVICE LOAD CALCULATION As an altematlve method, the STANDARD METHOD found In ARTICLE 220 of the National Electric Code., may be used 1. GENERAL LIGHTING LOADS Dwelling sq. ft. x 3 VA= 220-3(a) VA Small appliance loads -220-16(a) 1500 VA x circuits= VA Laundry load -220-16(b) 150.0 VA x circuits = ' VA General Lighting Total ______ VA 2. COOKJNG EQUIPMENT LOADS -Nameplate Value Range VA= VA Cooktop VA= VA Oven (s) VA= VA Cooking Equipment Total VA 3. ELECTRIC DRYER 220-18 (Nameplate, 5000 VA minimum) Dryer VA= Dryer Total . VA 4. FIXED APPLIANCE LOADS 230-30 (b) (3) Dishwasher = Disposal= Compactor= Water Heater = Hydrornassage Bathtub = Microwave Oven = Built-In Vacuum = = 5. OPTIONAL SUBTOTAL (Add all of the above totals) 6. APPLYING DEMAND FACTORS-TABLE 220-30 Flrst 10,000VAx 100% = Optional Subtotal (from line 5) { Remaining ___ VA x 40%= 7. HEATING OR AC LOAD -TABLE 220-30 Larger of the Heating or AC Load .., ____ VA ____ VA ____ VA· ____ VA ____ VA ____ VA ____ VA ____ VA Fixed Appliance Total ____ VA ____ VA 10,000 VA ____ VA ____ VA 8. OPTIONAL LOADS TOT AL (Add totals from llnes 6 and 7) = ____ VA 9. MINIMUM SERVICE SIZE 1:1 Optional Loads Total = ____ Ampere . 240 Volt (Please put total on front of card under Computed Load) . ' . ' .. Co11tii111011s lmpectio11 & Materials Testillg SOUTHWEST ············~·· v v V V V V T"7 v '<;'.7 v ~ ""v WW v Inspection & Testing, Inc. February 18, 2016 Building Official City of Carlsbad . Department of Building and Safety 1635 Faraday Ave Carlsbad, California 92008 441 Commercial Way, La Habra, CA 90631-6168 (562) 941-2990 • (714) 526-8441 FAX (562) 946--0026 SPECIAL INSPECTOR'S FINAL PROJECT REPORT Project Name: Address: Owner: ·Lot# Address Seagrove Townhomes State Street, PH 3 Bulldlng 5 Taylor Morrison Permit Lot# Address 31 2555 State Street CB151278 36 2535 State Street 32 2551 State Street CB151285 37 2531 State Street Permit CB151281 CB151280 33 2547 State Street CB151284 38 2527 State Street CB151279 34 2543 State Street CB151283 ~-i5zrsflileStceet_cB_1S.127Jr 35 2539 State Street CB151282 This Is to certify that Southwest Inspection and Testing, Inc. was employed to perform special Inspection on the above mentioned project at the above address, which required continuous Inspection per section 1701 of 2013 California Building Code. Brett Alblinger -Reinforced Concrete, Post Tensioned Concrete, SD #656 Nell White -Reinforced Concrete, Post Tensioned Concrete, ICC #5254958 Jeff Robertson-Reinforced Concrete, Post Tensioned Concrete, ICC # 5218723-92 Based upon special Inspection and materials testing written reports of this work, it is our judgment that the Inspected work was performed to the best of our knowledge, in accordance with the approved plans, specifications and applicable workmanship provision of the California Building Code. Steven L. G President SLG/IRW: amc Reviewed By: Ian R. Waddell, P.E. Prlnclpal Engineer Fo is e expressed or implied.