Loading...
HomeMy WebLinkAbout2525 El Camino Real; 230; CBC2017-0397; PermitCommercial Permit 'rint Date: 08/01/2018 ob Address: 'ermit Type: 1arcel No: laluation: lccupancy Group: 2525 El Camino Real, 230 BLDG-Commercial 1563020900 $ 70,462.65 Work Class: Tenant Improvement Lot#: Reference #: Construction Type Bathrooms: I Dwelling Units: ledrooms: Orig. Plan Check #: Plan Check#: Project Title: Description: FRANCESCAS: 1,515 SF RETAIL Tl Owner: R P I CARLSBAD LP 1114 Avenue Of The Americas, Floor 45 New York, NY 10036-7700 214-660-5232 X215232 FEE BUILDING PERMIT FEE $2000+ BUILDING PLAN CHECK FEE (BLDG) ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL PLUMBING BLDG COMMERCIAL NEW/ADDITION/REMODEL 581473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-COMMERCIAL Total Fees: $ 1,047.06 Total Payments To Date : $ 1,047.06 (city of Carlsbad Permit No: CBC2017-0397 Status: Applied: Issued: Permit Fina led: Inspector: Final Inspection: Closed -Expired 07/27/2017 09/14/2017 MColl AMOUNT $502.11 $346.22 $60.00 $45.00 $71.00 $3.00 $19.73 Balance Due: $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees /exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees /exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division EXPIRED PERMIT PERMIT HAS EXPIRED IN ACCORDANCE WITH c B C. SECTION 106.4.4 ftS AMENDED BY C.M.C.18.04.030 oAr~-1 ~,e _ s1GNATUREPt1t MI J<'E'. :p_ .,_ 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov .. THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0PLANNING 0ENGINEERING 0BUILOING 0FIRE OHEALTH 0HAZMATIAPCD A+ Ccityof Carlsbad Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 email: building@carlsbadca.gov Plan Check No. ce,(. 2Cf1 - Est. Value 10, 4-<..Q 3 _ Plan Ck. Deposit -' 3 '-/ (p, ;2 2---- www .carlsbadca.gov Date SW PPP GARAGE (SF) PATIOS (SF) DECKS (SF) AIR CONDITlONING NoCJ v,s oO FlRE SP~LERS YES1Z':JN00 {Sec. 7031.5 Business and P.rofessions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuanc , so requires he applicant for such permit to file a siitned statement that he is licensed pursuant to the provisions of the Contractor's license law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 1031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). WORKERS' COMPENSATION Workers Compensation Declaration: / hereby affirm under penalty of pequry one of the fol/owmg declarat10ns: 0 I have and will maintain a certificate of consent to seK-insure for wor!(ers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Bi have and will maintain work ' m?9nsatlon,ris required bl Section 37 of_ the Labor Code, for the performance of the rk which this rmit..f 1ssued. My wori(ers' compensation insurance carrier and licy number are: Insurance Co. ,JA. \ \ Policy No. '8 (p Expiration Date -/ -0 This section need not be c.ompleted if the permit is for one hundred dollars ($100) or less. .:r-;. 0 Certificate of Exemption: I certify that in the perfonnance of the wor!( for Which this permit is issued, I shall not employ any person in any manner so as to become subject to the Won<ers' Compensation Laws of California. WARNING; Failure to secure workers' co atlon coverage is unlawful, and shall subjeci an employer to criminal penalties and civn fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages asp vld r in Section 3706 of the Labor code, interest and attorney's fees. _25 CONTRACTOR SIGNATURE I hereby affirm that I am eiempt from Contractor's License Law for the following reason· 0 D D l, as owr.er of the property or my employees With wages as their sole compensation, wm do the wor!( and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's license law does not apply to an OWller of property who builds or improves thereon, and who does such wor!( himself or through his own employees, provided that such improvements are not intended or offered for sale. 11, however, the building or improvement is sold within one year Of completion, the owner..l)uilder will have the burden of proving that he did not build or improve for the purpose of sale). I, as OWller of the property, am exclusively contracting With licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the C0!1tractor's license Law). I am exempt under Section Business and Professions Code for this reason: 1. I personalty plan to provide the major labor and materials for construction of the proposed property improvement. 0Yes 0No 2. I (have I have not) signed an application for a building permit for lhe proposed work. 3. I have c.onttacted with the following person (firm) to provide the proposed construction (include name address I phone I contractors' license number): 4. 1 plan to provide portKlns of the wor!(, but I have hired the following person to coordinate, supervise and provide the major work {include name I address I phone I contractors' license number) 5. I will provide some of the work. but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone/ type of work): .I$ PROPERTY OWNER SIGNATURE DA.TE ... COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan,acutely hazardous materials registration form or risk management and prevention program under Sedans 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes )410 . Is lhe applicant or future building occupant required to obtain a permit from the air pollution control district or air queility management district? Yes ~o Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes '17'No I ·· IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UtJ'LESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I certify that I have read the appllcatlon and state tllattlle above lnfonnatlon Is correct and tllat the Information on the plans Is accurate. I agree to comply IMth all City ordinances and State 1av.s relating to bullding construction. I hereby authorize representafr.Je of the City of Carlsbad lo enter upon the above menOOned property for inspecoon purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES v.HICH MAY IN Atff WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: AA OSHA permit is required for excavations over 5'0' deep and demolition or construction of strucb.Jres over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by imitation and become null and void W the building or mrlc authorized by sucti pennil is not commenced 'hithin 180 days from the date of such permit or if the build in WOO( authori2R_ such perm~ is,. suspended or abandoned at any time after the work is commenced for a perKld of 180 days (Section 106.4 .4 UnWorm Building Code) . ..@S' APPLICANT'S SIGNATURE /_) ) DATE :-__...2-h"""---_-','---L---------~ STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. Fax (760) 602-8560, Email building@carlsbadca.gov or Mall the completed form to City of Carlsbad, Buildirig Division 1635 Faraday Avenue, Carlsbad, California 92008. CONTACT NAME L n UaJIC ADDRESS t ,,,-; CITY/)) PHONE (o I & EMAIL I DELIVERY OPTIONS PICK UP: CONTACT (Listed above) CONTRACTOR (On Pg. i) OCCUPANT (Listed above) MAIL TO: CONTACT (Listed above) ~lsted above) CONTRACTOR (On Pg. i) ~ MAIL/FAXTOOTHER: ________________ ~ .N$ APPLICANT'S SIGNATURE CO#: (Office Use Only) OCCUPANT NAME BUILDING ADDRESS 8700 C CITY _J _ STATE 01/?Tr}A) OCCUPANT'S BUS. LIC. No. ASSOCIATED CB#----···- ~HANGE IN usj}. CONSTRUCTION CHANGE OF USE/ NO CONSTRUCTION DATE 7 ;z7 /11 ZIP 77080 February 01, 2018 Owner/Tenant 2525 EL CAMINO REAL, Suite 230 Carlsbad CA 92008-1209 Carlsbad PERMIT NUMBER: CBC2017-0397 RE: BUILDING PERMIT EXPIRATION ISSUE DATE: 09/14/2017 PERMIT TYPE: BLDG-Commercial, Tenant Improvement ADDRESS: 2525 EL CAMINO REAL, Suite 230 Our records indicate that your building permit will expire by limitation of time on 04/24/2018. 18.04.030 Section 105.5 amended -Expiration: Every permit issued by the Building Officia I under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 calendar days from the date of such permit, or if the building or work authorized by such permit is stopped at any time after the work is commenced for a period of 180 calendar days, or if the building or work authorized by such permit exceeds three calendar years from the issuance date of the permit. Work shall be presumed to have commenced if the permittee has obtained a required inspection appr~val of work authorized by the permit by the Bui\1ing Official within 180 calendar days of the date of permit issuance. Work shall be presumed to be stopped if the permittee has not obtained a required inspection approval of work by the Building Official within each 180 day period upon the initial commencement of work authorized by such permit. Before such work can be recommenced, a new permit shall be obtained to do so, and the fee therefore shall be one half the amount required for a new permit for such work, and provided that no changes have been made or will be made in the original plans and specifications for such work, and provided further that such suspension or abandonment has not exceeded one year. In order to renew action on a permit after expiration, the permittee shall pay a new permit fee. Any permittee holding an unexpired permit may apply for an extension of time within which work may commence under that permit when the permittee is unable to commence work within the time period required by this section for good and satisfactory reasons. Please check below indicating your intentions and return this letter to us. 0 Project abandoned. A new permit will be obtained prior to commencing work. D Permit 180 day extension request, with written explanation including phone number and email address. Request will not be considered without explanation 0 Renewal permit requested. If the project has been completed and only a final inspection is needed, please call the inspection request line at (760) 602-2725. lf you have any questions, please contact the Building Inspection Division at 760-602-2700. Community & Economic Development Building Division I 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov ' ' t ,0,,, ' ' . PERMIT INSPECTION HISTORY REPORT (CBC2017-0397) Perm it Type: BLDG-Commercial Application Date: 07/27/2017 Owner: R P I CARLSBAD LP Work Class: Tenant Improvement Issue Date: 09/14/2017 Subdivision: CARLSBAD TCT#76-18 Status: Closed -Expired Expiration Date: 05/14/2018 Address: 2525 El Camino Real , 230 Carlsbad, CA 92008 IVR Number: 5290 ,cheduled Actual Inspection Type Date Start Date Inspection No. Inspection Status Primary Inspector Reinspection Complete 10/26/2017 10/26/2017 BLDG-21 038634-2017 Partial Pass Michael Collins Reinspection Incomplete Underground/Underf loor Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Accessibility questions No 11/06/2017 11/06/2017 BLDG-91 039698-2017 Passed Michael Collins Complete Complaints Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Ok to stock & train only Yes 11/15/2017 11/15/2017 BLDG-Final 040501-2017 Partial Pass Michael Collins Re inspection Incomplete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency TCO only, see card Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes August 01, 2018 Page 2 of 2 ¢ ' ' "\ " ~{ ,:,,, '' ' · .-. , . , PERMIT IN.SPECTION HISTORY REPOR4 (CBC2017-0397) Perm it Type: BLDG-Commercial Work Class: Tenant Improvement Status: Closed -Expired Scheduled Date Actual Start Date Inspection Type Application Date: 07/27/2017 Owner: R P I CARLSBAD LP Issue Date: 09/14/2017 Subdivision: CARLSBAD TCT#76-18 Expiration Date: 05/14/2018 Address: 2525 El Camino Real , 230 IVR Number: 5290 Carlsbad, CA 92008 Inspection No. Inspection Status Primary Inspector Reinspection Complete ------·---·---·-------- 09/18/2017 09/18/2017 BLDG-44 Rough/Ducts/Oampe rs 034995-2017 Checklist Item BLOG-Building Deficiency 10/03/2017 10/03/2017 BLDG-84 Rough 036607-2017 Combo(14,24,34,44) Passed Michael Collins COMMENTS Ore lim HVAC duct sealing Passed Michael Collins Checklist Item COMMENTS BLDG-Building Deficiency Walls only BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers 10/12/2017 10/12/2017 BLDG-85 T-Bar, Ceiling Grids, Overhead 037211-2017 Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers 10/13/2017 10/13/2017 BLDG-17 Interior Lath/Drywall 037701-2017 Checklist Item BLDG-Building Deficiency 10/16/2017 10/16/2017 BLDG-17 Interior Lath/Drywall 037838-2017 Checklist Item BLDG-Building Deficiency 10117/2017 10/17/2017 BLDG-17 Interior Lath/Drywall 037709-2017 Checklist Item BLDG-Building Deficiency Checklist Item BLDG-Building Deficiency August 01, 2018 Passed Paul Burnette COMMENTS Partial Pass Michael Collins COMMENTS Partial hard lid screws, Line F-G & 21-22 Passed Michael Collins COMMENTS remainder of hard lid at sales Passed Michael Collins COMMENTS COMMENTS Repeat of same inspection on same day. Complete Passed Yes Complete Passed Yes Yes Yes Yes Yes Complete Passed Yes Yes Yes Yes Yes Reinspection Incomplete Passed Yes Complete Passed Yes Complete Passed Yes Passed Yes Page 1 of 2 EsGil Corporation In tJ.'artnersnip witn government for /JJuiCaing Safety DATE: 9/7/17 JURISDICTION: City of Carlsbad PLAN CHECK NO.: CBC2017-0397 SET: III PROJECT ADDRESS: 2525 El Camino Real Suite 230 PROJECT NAME: Francesca's -TI 0 APPLICANT ~JURIS. 0 PLAN REVIEWER 0 FILE ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ EsGil Corporation staff did not advise the applicant that the plan check has been completed. D EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: 4,-Telephone#: Date contacted: (by:171---) Email: Mail Telephone Fax In Person D REMARKS: By: Jason Pasiut Enclosures: EsGil Corporation D GA D EJ D MB D PC 8/30/17 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 EsGil Corporation In <Partners nip wit ft (jovernment for (}Jui(tfin9 Safety DATE: 8/23/17 JURISDICTION: City of Carlsbad PLAN CHECK NO.: CBC2017-0397 SET: II PROJECT ADDRESS: 2525 El Camino Real Suite 230 PROJECT NAME: Francesca's -TI 0 APPLICANT ~ JURIS. 0 PLAN REVIEWER 0 FILE 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. 0 The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [gl The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [gl The applicant's copy of the check list has been sent to: lynd@precisionpermits.com D EsGil Corporation staff did not advise the applicant that the plan check has been completed. [gl EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Lyn Davies Telephone#: 616-493-9350 Date contacted: ~V5/17 (by$) Email: lynd@precisionpermits.com ~elepho~ Fax In Person D REMARKS: ,'INS'~ By: Jason Pasiut (for DM} EsGil Corporation D GA D EJ D MB D PC Enclosures: 8/16/17 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 City of Carlsbad CBC201 7-0397 8/23/17 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. * 4. 5. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carts bad Planning, Engineering and Fire Departments. 2. Bring two corrected sets of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. Please revise code section for special inspection of the cold-formed steel light-framed construction to the appropriate section of the CBC. Please provide an enlarged dimensioned restroom plan consistent with the floor plans. The enlarged plan does not comply with the accessibility requirements and the floor plans restroom may not comply as no interior width dimensions are provided. The restroom detail on sheet A-300 does not match the layout on sheets A-003 and A-101. Also, the detail on sheet A-300 shows the mop sink within the 60" x 48" maneuvering space required in front of the water closet. Please revise. 11 B-604.3.1. Show that at least one water closet fixture shall provide the following, per Section 11 B-604: a) One side of the water closet shall provide 17" -18" from the centerline of the water closet to the adjacent wall. Revise detail 1 on sheet A-300 to reflect 17" minimum. END OF REVIEW To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans: EsGil Corporation In <Partnersnip witn (}overnment for (JJuiUino Safety DATE: 8/10/17 JURISDICTION: City of Carlsbad PLAN CHECK NO.: CBC2017-0397 SET: I PROJECT ADDRESS: 2525 El Camino Real Suite 230 PROJECT NAME: Francesca's -TI D APPLICANT ~ JURIS. 0 PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. cg] The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: D EsGil Corporation staff did not advise the applicant that the plan check has been completed. cg] EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Lyn Davies Telephone#: 616-493-9350 Date contacted:&"holn (by: j)J') Email: lynd@precisionpermits.com C::-"E7Mail TelephoneVtn' Fall; In Person D REMARKS: By: Doug Moody EsGil Corporation D GA D EJ D MB D PC Enclosures: 7/31/17 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 City of Carlsbad CBC2017-0397 8/10/17 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: CBC2017-0397 OCCUPANCY: M TYPE OF CONSTRUCTION: IIB ALLOWABLE FLOOR AREA: SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 7/2717 DATE INITIAL PLAN REVIEW COMPLETED: 8/ 10/ l 7 FOREWORD (PLEASE READ): JURISDICTION: City of Carlsbad USE: Retail ACTUAL AREA: 1515sf STORIES: 1 HEIGHT: OCCUPANT LOAD: 22 DATE PLANS RECEIVED BY ESGIL CORPORATION: 7/31/17 PLAN REVIEWER: Doug Moody This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2016 CBC, which adopts the 2015 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad CBC201 7-0397 8/10/17 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: CBC2017-0397 PREPARED BY: Doug Moody DATE: 8/10/17 BUILDING ADDRESS: 2525 El Camino Real Suite 230 BUILDING OCCUPANCY: M BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: D Repetitive Fee ~J Repeats Comments: AREA Valuation ( Sq. Ft) Multiplier 1515 46.51 By Ordinance ... -... 1 Complete Review D Other D Hourly EsGil Fee Reg. VALUE Mod. D Structural Only 1-------11 Hr. @ • ($) 70,463 70,463 $494.131 $321.181 $281.651 Sheet 1 of 1 macvalue.doc + City of Carlsbad CBC2017-0397 8/10/17 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring two corrected sets of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Provide a section view of the new hard-lid ceilings. Show: a) Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICC approved". b) Method of attaching top to the structure and lateral bracing. c) Show height of the hard-lid ceilings from floor, hard-lid ceilings to roof framing or floor framing. 2. Provide the following information concerning the water heater: • Show that water heater is adequately braced to resist seismic forces. Provide two straps. One strap at top 1 /3 of the tank and one strap at bottom 1 /3 of the tank. UPC 508.2 3. Please correct the plumbing plans the water closet 4" line is connecting to a 3" drain? Section 107.2. 4. Please provide an enlarged dimensioned restroom plan consistent with the floor plans. The enlarged plan does not comply with the accessibility requirements and the floor plans restroom may not comply as no interior width dimensions are provided. 5. Show that at least one water closet fixture shall provide the following, per Section 11 B-604: a) One side of the water closet shall provide 17" -18" from the centerline of the water closet to the adjacent wall. 6. Please revise the plans to show 2:1 fitting room or dressing room for the customers shall be provided as follows: i) Show a 24" x 48" bench: a) Mounted 2:17" but :S:19". City of Carlsbad CBC2017-0397 8/10/17 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes D No D The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. STRUCTURAL CALCULAl"IONS PREPARED FOR: FRANCESCA'S THE SHOPPES AT CARLSBAD 2525 EL CAMINO REAL CARLSBAD, CA 92008 STRUCTURAL CALCULATIONS TOTAL No. SHEETS (NOT INCLUDING THIS SHEET): DATE: 7/19/2017 . I Nick Sung, P.E. 3260 W. HENDERSON Ro. SUITE 10 COLUMBUS, OH 43220 Ph: 614-326-2806 Fx: 614-326-2805 Design Code: 2016 California Building Code Referenced Standards Structural Calculations FRANCESCA'S Century City Los ANGELES, CA Grabber Drival Self Drilling Screws (ICC ESR-1271)(LABDS NO. RR 25509) Metal Studs (ICC ESR-1166P)(LABDS NO. RR 25889) Suspended Ceiling Design Loads: DL = 7 psf (Gyp Board Ceiling) 2 psf (Framing system) .1...Qfil (Misc.) 10 psf or 200 lbs cone. load (whichever is greater) Seismic: Ss = 2.208 S1 = .817 Site Class = D (assumed) F. = 1.0 Fv = 1.5 Sos= (2/3)F,Ss = 1.472 So1 = (2/3)F,S, = .817 Occupancy Category = II Seismic Design Category = D Structural element: Ceilings ap=1.0 Rp=2.5 lp=1.0 z=12' -.4apSDSwp ( !.-)-Fp-RP/IP 1+2 h -.52Wp Fp (max) = 1.6 Sos Ip Wp = 2.36 Wp Fp (min.) = .3 Sos Ip Wp = .44 Wp Bracing Wire h = 20' (4) 12 Ga. Hanger/Bracing Wires @4'-0" o.c. each way DL Tension= (1/4)(10 psf)(4')(4')/cos 45' = 57 lbs OR = (1/4)(200 lbs)/cos 45' = 71 lbs (controls) Seismic Tension= (.52)(50 lbs)/cos 45' = 37 lb Total Tension = 71 lbs+ 37 lbs= 108 lbs per wire A . = 1tD2 = ir(. 053 )2 . 0088 in2 Wire 4 4 T f,=--= 12.3 ksi A wire ASTM A641/A641m F, = 36 ksi min., Fu= 58 ksi F, = .60 F, = 21.6 ksi OR= .50 Fu= 29 ksi O.K. -I - Nick Sung, P.E. 3260 w. HENDERSON Ro. Su1TE 10 COLUMBUS, OH 43220 Ph: 614-326-2806 Fx: 614-326-2805 Storefront Framing Design Loads: Structural Calculations FRANCESCA'S Century City Los ANGELES, CA Dead Load: Storefront framing (mtl. stud beams, etc.) conservatively designed for a vertical load of 100 plf. Seismic: See page 1 for additional seismic info. Structural element: Nonstructural Wall Elements ap = 1.0 Rp = 2.5 Ip= 1.0 z = 12' h = 20' .4apSDSwp ( z)-Fp= RP/IP 1+2h -.52Wp Fp (max) = 1.6 Sos Ip Wp = 2.36 Wp Fp (min.) = .3 Sos Ip Wp = .44 Wp Framing Support Box Beams: (2) 8" x 18 ga. Mtl. Box Header Max. span L = 12'-0", w = 100 plf See attached computer output O.K. Deflection = .175" = L/824 O.K. Framing Support Box Beams: (2) 3 5/8" x 18 ga. Mtl. Box Header Max. span L = 8' -6", w = 50 plf See attached computer output O.K. Deflection = .140" = L/727 O.K. Lateral Braces 3-5/8" x 20 ga. Studs @ 48" o.c. L = 12'-0" max. (fully unbraced) Brace Loads: Seismic= (.52)(100 plf)(4'-0")/(1.4)/(cos 45°) = 209 lbs Pa11ow = 840 lbs (AISI Eq. C5.2.1-1) 0.K. Braces attach to framing with (4) #10 SDS screws Va11ow = (4)(164 lbs per screw)= 656 lbs 0.K. -2- ClarkWestern Building Systems CW Tech Support: (888) 437-3244 clarkwestern.com 2007 North American Specification ASD DATE: 7/24/2017 SECTION DESIGNATION: 800S162-43 [33] (2) Boxed Input Properties: Web Height= Top Flange= Bottom Flange = Stiffening Lip = Punchout Width = 8.000 in 1.625 in 1.625 in 0.500 in 1.500 in Header/Beam Solver Design Data -Simple Span Design Thickness = Inside Corner Radius = Yield Point, Fy = Fy With Cold-Work, Fya = Punchout Length = Defiection Limit L/240 Header/Beam Span 12. 00 ft Dead Load= 100.0 lb/ft DL Multiplied by 1.00 for Strength Checks Check Flexure Input Flexural Bracing: None Cb=1.14 lyy (Box) = 2.071 in'4 J (Box) = 5.253 in'4 Lu= 1012.4 in Mmax = 1800 Ft-Lb <= Ma = 3357 Ft-Lb Check Deflection Deflection Limit: L/240 Maximum Deflection = 0.175 in Check Shear Vmax = 600 lb (Including Flexural Load Multiplier) Deflection Ratio = L/824 Shear capacity not reduced for punchouts near ends of member Va= 2102 lb>= Vmax Check Web Crippling Rmax = 600 lb (Including Flexural Load Multiplier) Web Crippling capacity not reduced for punchouts near ends of member End Bearing Length = 1.00 in Ra = 494 lb < Rmax, STIFFENERS REQUIRED 0.0451 in 0.0712 in 33.0 ksi 33.0 ksi 4.000 in ClarkWestern Building Systems CW Tech Support: (888) 437-3244 clarkwestern.com 2007 North American Specification ASD DATE: 7/24/2017 SECTION DESIGNATION: 3625162-43 [33] (2) Boxed Input Properties: Web Height= Top Flange= Bottom Flange = Stiffening Lip = Punchout Width = 3.625 in 1.625 in 1.625 in 0.500 in 1.500 in Header/Beam Solver Design Data -Simple Span Design Thickness = Inside Corner Radius = Yield Point, Fy = Fy With Cold-Work, Fya = Punchout Length = Deflection Limit L/240 Header/Beam Span 8.50 ft Dead Load = 50.0 lb/ft DL Multiplied by 1.00 for Strength Checks Check Flexure Input Flexural Bracing: None Cb= 1.14 lyy (Box)= 1.058 in'4 J (Box)= 1.750 in'4 Lu = 1235.2 in Mmax = 452 Ft-Lb <= Ma = 1224 Ft-Lb Check Deflection Deflection Limit: L/240 Maximum Deflection= 0.140 in Check Shear Vmax = 213 lb (Including Flexural Load Multiplier) Deflection Ratio = L/727 Shear capacity not reduced for punchouts near ends of member Va = 3478 lb>= Vmax Check Web Crippling Rmax = 213 lb (Including Flexural Load Multiplier) Web Crippling capacity not reduced for punchouts near ends of member End Bearing Length = 1.00 in Ra = 553 lb >= Rmax, stiffeners not required 0.0451 in 0.0712 in 33.0 ksi 33.0 ksi 4.000 in EOSGS Design Maps Summary Report User-Specified Input Report Title Francesca's-Carlsbad, CA Th July 20, 7017 14 ·4':i 40 UTC Building Code Reference Document 2012/2015 International Building Code , wh1c:l1 utt111cs dSGS hanm1 data ava,lahl<' ,n 200S) Site Coordinates 33.15848°N, 117.34585°W Site Soil Classification Site Class D -"Stiff Soil" Risk Category I/II/III USGS-Provided Output S5 = 1.151 g S1 = 0.441 g ., -it ~,,·lcict ,,, ~· iii Oceanside SMS = 1.197 g SM1 = 0.688 g A,tr •-"l S 05 = 0.798 g S 01 = 0.459 g Stn Marc,os fl I Escondldo• For information on how the SS and S1 values above have been calculated from probabilistic (risk-targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. Dc9'4'1 ~u!l;.,0·1sc Socc\·um •.,\ ,. l;'\, li'l'I (l C •,t ~ Cl 0 (Jr~, VI ,:\UI ti~~ f!r't J ., c, .• (1().1 (.J'< J ~\ . ~ , , " \ , ,, 1 ti ) •'· I tl t 1,l I 01 • ,,· Although this tnfor mallol' 1s a product of tile U.S. Gcolomcal Survey, we p10111dc no wm ranty, cxp;c::,scd or 1111plicd, as lCl u,c accuracy of the data cont.ai11cd tl1pre111. Thi'> tool 1::, •10• r1 ~ubst,tute ror teL11111c<1I sub1ect-11i.11.1.,·1 kn,iwlcc!qc. a: . '' ..... INDUSTRIAL WASTEWATER DISCHARGE PERMIT Date--1k'l / i l SCREENING SURVEY Business Name_--::s--c-:::----'-'-,:-;--e-"---==-"--"'--"--"~"---,::----:---,-.,.--=--=--- Street Address dJ:. ' ?;, 0 Email Address,_,_..µ-'-"'c....:::+'-'--'~L<CLJ,'fi/'.LS~Lll.LL..LJ...L.J.J..,.!E.!,~------~?-- PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) Check all below that are present at your facility: . .. Acid Cleaning Ink Manufacturing Nutritional Supplement I Assembly Laboratory Vitamin Manufacturing Automotive Repair Machining I Milling Painting I Finishing Battery Manufacturing Manufacturing Paint Manufacturing Biofuel Manufacturing Membrane Manufacturing Personal Care Products Biotech Laboratory (i.e. water filter membranes) Manufacturing Bulk Chemical Storage Metal Casting I Forming Pesticide Manufacturing I Car Wash Metal Fabrication Packaging Chemical Manufacturing Metal Finishing Pharmaceutical Manufacturing Chemical Purification Electroplating {including precursors) Dry Cleaning Electroless plating Porcelain Enameling Electrical Component Anodizing Power Generation Manufacturing Coating (i.e. phosphating) Print Shop Fertilizer Manufacturing Chemical Etching I Milling Research and Development Film I X-ray Processing Printed Circuit Board Rubber Manufacturing Food Processing Manufacturing Semiconductor Manufacturing Glass Manufacturing Metal Powders Forming Soap I Detergent Manufacturing Industrial Laundry Waste Treatment/ Storage SIC Code(s) (if known): _____________________ _ Brief description of business activities (Production I Manufacturing Operations):. _____ _ Description of operations generating wastewater ( discharged to sewer, hauled or evaporated): Estimated volume of industrial wastewater to be discharged {gal I day): -------- List hazardous wastes generated (type /volume): ______________ _ Date operation began/or will begin at this location: --------------- Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? Yes No If yes, when:--------------------- Site Contact {2_ Title Signature ?tf~ lJ (A,V) f(} Phone No. 0/(o L/q:z q37c) ENCi NA WASTEWATER AUTHORITY, 6200 Avenida Encinas Carlsbad, CA 92011 (760) 438-3941 FAX: (760) 476-9852 OFFICE USE ONLY SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE RECORDID#~~~~~~~~~~~~~~~~~I PLAN CHECK#~~~~~~~~~~~~~~~~ BP DATE Business Name (',1J7C-e'.";ca· ProjecAAddress APN# o( '5 ;;_ "'.5 l7b 30:).. 01 00 Mailing Address State Plan File# Project Contact (_ The following question represe t the faclllty's a tlvities, NOT the specific project description. P~T I: Fl~E DEP~T~ENT . HAZARDOUS MATERIALS DIVlSION: OCCUPANCY CLASSIFICATION: (not required for projects within the City of San Qi!.QQl: Indicate by c1rchng the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: Facility's Square Footage (including proposed project): 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives Corrosives 2. Compressed Gases 6. Oxidizers 10. Cryogenics 3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 4. Flammable Solids 8. Unstable Reactives 12. Radioactives 13. 14. 15. Other Health Hazards None of These. PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH HAZARDOUS MATERIALS DIVISION /HMD): If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Avenue, Suite 110, San Diego, CA 92123. Call (858) 505-6700 prior to the issuance of a building permit. FEES ARE RED Project Completion Date: YES NO Expected Date of Occupancy: 1. 2. 3. 4. 5. 6. 7. 8. D D D D D D D D (for new construction or remodeling projects) Is your business listed on the reverse side of this form? (check all that apply). Will your business dispose of Hazardous Substances or Medical Waste in any amount? Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 pounds and/or 200 cubic feet? Will your business store or handle carcinogens/reproductive toxins in any quantity? Will your business use an existing or install an underground storage tank? Will your business store or handle Regulated Substances (CatARP)? Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to or reater than 1,320 allons? California's Above round Petroleum Stora e Act . 0 CalARP Exempt I Date Initials 0 CalARP Required I Date Initials 0 CalARP Complete I Date Initials PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCD): Any YES* answer requires a stamp from APCD 10124 Old Grove Road, San Diego, CA 92131 apcdcomp@sdcounty.ca.gov (858) 586-2650). [*No stamp required if 01 Yes and 03 Yes and 04-06 No]. The following questions are intend.ed to identify the majority of air pollution issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive requirements contact APCD. Residences are typically exempt, except -those with more than one building+ on the property; single buildings with more than four dwelling uni,, wnhomes; condos; mixed-commercial use; deliberate burns; residences forming part of a larger project. [+Excludes garages & small outbuildings.] YES N 1. D Will the project disturb 160 square feet or more of existing building materials? 2. D Will any load supporting structural members be removed? Notification may be required 10 working days prior to commencing demolition. 3. D (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance Technician? 4. D D (ANSWER ONLY JF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification may be required 10 working days prior to commencing asbestos removal. 5. O Jt' Will the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCD factsheet (www.sdapcd.org/infolfacts/permits.pdf) for typical equipment requiring an APCD permit. 6. D D (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school bound a 1 I 2.C;, I 17 FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: ________________ --,-----,------------ BY DATE' I I FOR OFFICAL USE ONLY, EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMo• APCD COUNTY-HMO APCD COUNTY-HMO APCD *A stamp 1n this box 2!W{ exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may sttll apply. HM-9171 (08/15) County of San Diego -DEH -Hazardous Materials Division