2525 EL CAMINO REAL; 216; CBC2017-0630; Permit
(rcity of Carlsbad Permit No: CBC2017-0630 Print Date: 06/24/2019 Job Address: 2525 El Camino Real, 216 Permit Type: BLDG-Commercial Work Class: Tenant Improvement Parcel No: 1563020900 Lot #: Valuation: $ 46,463.49 Reference #: Occupancy Group: Construction Type U Dwelling Units: Bathrooms: Bedrooms: Orig. Plan Check U: Plan Check U: Project Title: Description: NEKTER: 999 SF T.I. SHELL TO JUICE BAR Status:. Closed - Expired Applied: 12/01/2017 Issued: 02/12/2018 Permit Finaled: Inspector: MColI Final. Inspection: Applicant: Owner: TAMER GERGIS R P I CARLSBAD.LP 27 Orchard LAKE FOREST, CA 92630 1114 Avenue Of The Americas, Floor 45 949-716-9990 New York, NY 10036-7700 214-660-5232 x215232 FEE AMOUNT BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL PLUMBING BLDG COMMERCIAL NEW/ADDITION/REMODEL 5B1473 GREEN BUILDING STATE STANDARDSFEE STRONG MOTION-COMMERCIAL $386.80 $270.76 $43.00 $45.00 $63.00 $2.00 $13.01 Total Fees: $ 823.57 Total Payments To Date: $ 823.57 Balance Due: $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees /exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-2700 .1 760-602-8560* f I www.carlsbadca.gov THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: LANNING GINEERING MfBUILDING IRE 52fHEALTH IA2MAT!APCD Building Permit Application Plan Check No Est. Value (ricity of 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Cdisbad Plan Ck. Deposit email: building@carlsbadca.gov Date Z)/ I ft 1 Iswppp I www.carlsbadca.gov JOB ADDRESS 2525 El Camino Real I SUITh#/SPACE#/UNIT# I 2I APN I - - - Cr/PROJECT# LOT# PHASE# #OFUNITS #BEDROOMS NAME CONSTR. TYPE I T11ATHROOMBITENAPITBUSINESS 0CC. GROUP Nekter Juice Bar Ill-B B DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) Converting existing 999 Sq.% vacant space into new Nekter Juice Bar. New accessible Restroom, New interior partitions, ceiling & finishes; new Electrical service; new HVAC ducts; New Plumbing. EXISTING USE ED USE GARAGE (SF) PATIOS(SF) FIREPLACE AIR CONDITIONING 1 '005Juice Bar I DECKS(SF) I YESa. NOD I YES NO IFIRESPRINKLERS YESNOE APPLICANT NAME Tamer Gergis PROPERTY OWNER NAME Primary Contact ADDRESS 27 Orchard ADDRESS CITY STATE ZIP CITY STATE ZIP Lake Forest CA 92630 PHONE FAX PHONE FAX 9497169990 I EMAIL EMAIL tamer.gergis@nationaleng.com DESIGN PROFESSIONAL Michael_Santillan CONTRACTOR BUS. NAF"E Vikin__________________________________________ ADDRESS 27 Orchard ADDRESS '51 so Poo 70C.6 )&iti#: CITY STATE ZIP CITY STATE ZIP Lake Forest CA 92630 e,*4.44( PHONE FAX I FFA 9497169990 -Is i - PHONE 7Go' if • .'° EMAIL michael.santillannationaleng.com EMA LII I.CIf4e v k,.s, e.. • Lvisi STATE LIC. # C-23337 STATE uc.# S'V9si ICss Ia;e' I CITY BUS. i LIC C (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License LawfChapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a Civil penalty of not more than five hundred dollars ($500)). I 000(31300' 0910®l9 Workers' Compensation Declaration: thereby affirm under penalty of pe4uiy one of the following declarations: BI have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the perfonnance of the work for which this permit is issued. I have and will maintain workers' compensation, as required by Sectio 700 of the Labor Code for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co._ f!IJ1s.l,&4paiI.II h*' ,rM4,I.I1 Policy No. _a S" 9 '1." Expiration Date_ ' I This section need not be completed if the permit is for one hundred dollars ($100) or less. ti Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (11,100,000), in addition to the cost of compensation, damages as provIded for in Sectioj 3706 of the Labor code, interest and attorney's fees. CONTRACTOR SIGNATURE d1t, r-i fSf,--,.,. 0 AGENT DATE i/i I ®@D®D ®?009 I thereby affirm that tam exempt from Contractors License Law for the following reason: I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. if, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section Business and Professions Code for this reason: I personally plan to provide the major labor and materials for construction of the proposed property improvement. DYes DNo I (have! have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name address! phone! contractors' license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name! address! phone! contractors' license number): I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/address! phone! type of work): PROPERTY OWNER SIGNATURE []AGENT DATE 17l003 09GU00G9 90151® @O®l3E)17O O(UO(®O(J( Jo ®G)( Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25553 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Yes No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. (®(!3(?O®() G(()OQJ® ®1307 thereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lenders Name Lenders Address OG1? OO?O® Iceitir that Ihave read the application and statethatthe above inibmiation is coffectand thatthe information on the plans isaccurate. I agree to comptywith all City ordinances and State laws relatingto building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA An OSHA permit is required for excavations over 50' deep and demolition or construction of structures over stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expireby limitation and become null and void if the building or work authorized by such permit is not commenced within l8o days from the date ofsuch permit orif the building orwork authorized by such permit issuspended or abandoned at any time after the work uscomenced fora period of 180 days (Section 1064.4 Uniform Building Code). 'APPLICANT'S SIGNATURE --Gww Af~e~ 4ir DATE 11. '30. 20( STOP. THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. (Co m mercialCEnTIFICATE OF OCCUPANCY . Fax (760) 602-8560, Email building@carlSbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. CO#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX EMAIL OCCUPANT'S BUS, LIC. No. DELIVERY OPTIONS PICK UP: CONTACT (Usted above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) ASSOCIATED CB# MAIL TO: CONTACT (Usted above) OCCUPANT (Listed above) CONTRACTOR (On Pg.i) NO CHANGE IN USE/ NO CONSTRUCTION MAIL/ FAX TO OTHER: CHANGE OF USE / NO CONSTRUCTION .APPLICANT'S SIGNATURE DATE hty of Carlsbad August 14, 2018 Owner/Tenant 2525 EL CAMINO REAL, Suite 216 Carlsbad CA 92008-1208 PERMIT NUMBER: CBC2017-0630 RE: BUILDING PERMIT EXPIRATION ISSUE DATE: 02/12/2018 PERMIT TYPE: BLDG-Commercial, Tenant Improvement ADDRESS: 2525 EL CAMINO REAL, Suite 216 Our records indicate that your building permit will expire by limitation of time on 10/09/2018. 18.04.030 Section 105.5-amended - Expiration: Every permit issued by the Building Official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 calendar days from the date of such permit, or if the building or work authorized by such permit is stopped at any time after the work is commenced for a period of 180 calendar days, or if the building or work authorized by such permit exceeds three calendar years from the issuance date of the permit. Work shall be presumed to have commenced if the permittee has obtained a required inspection approval of work authorized by the permit by the Building Official within 180 calendar days of the date of permit issuance. Work shall be presumed to be stopped if the permittee has not obtained a required inspection approval of work by the Building Official within each 180 day period upon the initial commencement of work authorized by such permit. Before such work can be recommenced, a new permit shall be obtained to do so, and the fee therefore shall be one half the amount required for a new permit for such work, and provided that no changes have been made or will be made in the original plans and specifications for such work, and provided further that such suspension or abandonment has not exceeded one year. In order to renew action on a permit after expiration, the permittee shall pay a new permit fee. Any permittee holding an unexpired permit may apply for an extension of time within which work may commence under that permit when the permittee is unable to commence work within the time period required by this section for good and satisfactory reasons. Please check below indicating your intentions and return this letter to us. 0 Project abandoned. Anew permit will be obtained prior to commencing work. 0 Permit 180 day extension request, with written explanation including phone number and email address. Request will not be considered without explanation 0 Renewal permit requested. If the project has been completed and only a final inspection is needed, please call the inspection request line at (760) 602-2725. If you have any questions, please contact the Building Inspection Division at 760-602-2700. Community & Economic Development Building Division 1 1635 Faraday Avenue, Carlsbad, CA 92008-7314 1 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov Permit Type: BLDG-Commercial Application Date: 12/01/2017 Owner: R P I CARLSBAD LP Work Class:, Tenant Improvement Issue Date: 02/12/2018 Subdivision: CARLSBAD TCT#76-18 Status: Closed - Expired Expiration Date: 11/05/2018 AddreSs: 2525 El Camino Real 216 Carlsbad, CA 92008 IVR Number: 8101 Scheduled Date Actual Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete 0212012018 0212012018 BLDG-24 049191.2018 Partial Pass Michael Collins Reinspection Incomplete RoughlTopout Checklist Item COMMENTS Passed BLDG-Building Deficiency See card for pick up notes Yes BLDG-43 Air 049192.2018 Failed Michael Collins Reinspection Complete Cond.IFumace Set Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No 0212212018 0212212018 BLDG-14 049499.2018 Cancelled Michael Collins Reinspection Complete Frame/Steel/Bolting/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Cancelled, not ready No BLDG-44 049500.2018 Partial Pass Michael Collins Reinspection Incomplete RoughlDuctslDampe rs Checklist Item COMMENTS Passed èLDG-Building Deficiency. Prelim spiral duct sealing Yes 0212312018 0212312018 BLDG-14 049686.2018 Failed Paul Bumette Reinspection Complete Frame/Steel/Bolting/ Welding (Decks) Checklist Item - COMMENTS Passed BLDG-Building Deficiency No BLDG-17 Interior 049687-2018 Partial Pass Paul Bumette Reinspection Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-24 049688.2018 Partial Pass Paul Bumette Reinspection Incomplete RoughlTopout Checklist Item COMMENTS Passed BLDG-Building Deficiency See card for pick up notes - Yes BLDG-34 Rough 049689.2018 Partial Pass Paul Bumette Reinspection Incomplete Electrical Checklist Item COMMENTS Passed BLDG-Building Deficiency No 0212612018 0212612018 BLDG-14 049846.2018 Partial Pass Michael Collins Relnspectlon Incomplete FramelSteellBoltingl . Welding (Decks) - June 28, 2019 . . Page lof4 Permit Type: BLDG-Commercial Application Date: 12101/2017 Owner: R P I CARLSBAD LP Work Class: Tenant Improvement Issue Date: 02/12/2018 Subdivision: CARLSBAD TCT#76-18 Status: Closed - Expired Expiration Date: 11/05/2018 Address: 2525 El Camino Real 216 Carlsbad, CA 92008 IVR Number: 8101 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Walls at BOH, Rm 102,104 Yes BLDG-Building Deficiency Cancelled, not ready No BLDG-24 049847.2018 Passed Michael Collins Complete Rough!Topout Checklist Item COMMENTS Passed BLDG-Building Deficiency Top out through roof. Yes BLDG-Building Deficiency See card for pick up notes Yes BLDG-34 Rough 049845-2018 Partial Pass Michael Collins Reinspection Incomplete Electrical Checklist Item COMMENTS Passed BLDG-Building Deficiency BOH, Rm 102,104, see card. Yes 0212812018 0212812018 BLDG-16 Insulation 050137.2018 Failed Michael Collins Reinspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Need demising walls No BLDG-17 Interior 050139.2018 .Partial Pass Michael Collins Reinspection Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Back of house Yes BLDG-84 Rough 050138.2018 Passed Michael Collins Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Completion of wall frame Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes 03/0112018 0310112018 BLDG-17 Interior 050295.2018 Partial Pass Michael Collins Reinspection Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Service area clip walls Yes BLDG-Building Deficiency Back of house Yes 0310712018 03/0712018 BLDG-17 Interior 050856.2018 Passed Michael Collins Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Restroom, service/sales Yes BLDG-Building Deficiency Service area clip walls Yes BLDG-Building Deficiency Back of house Yes June 28, 2019 - Page2 of 4 Permit Type: BLDG-Commercial Application Date: 12/01/2017 Owner: R P I CARLSBAD LP Wàrk Class: Tenant Improvement Issue Date: 02/12/2018 Subdivision: .CARLSBAD TCT#76-18 Status: Closed - Expired Expiration Date: 11/05/2018 Address: 2525 El Camino Real , 216 Carlsbad, CA 92008 IVR Number: 8101 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete 03/12/2018 0311212018 BLDG-85 T-Bar, 051358-2018 Failed Michael Collins Reinspection Complete Ceiling Grids, Overhead Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No 0313012018 03130I2018 BLDG-85 T-Bar, 053404-2018 Partial Pass Michael Collins Reinspection Incomplete Ceiling Grids, Overhead - Checklist Item COMMENTS Passed, BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Pending Fire Dept release No 0410512018 0410512018 BLDG-17 Interior 054241-2018 Passed Michael Collins Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Sales floor hard lid. Yes BLDG-85 T.Bar, 053948-2018 Passed Michael Collins Complete Ceiling Grids, Overhead Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Building Deficiency Pending Fire Dept. release No BLDG-Building Deficiency Not ready No 04/1012018 04/10/2018 BLDG-16 Insulation 054482-2018 Partial Pass Michael Collins Reinspection Incomplete Checklist Item COMMENTS . Passed BLDG-Building Deficiency Partial demising walls Yes BLDG-Building Deficiency Need demising walls No 04I12I2018 04112/2018 BLDG-16 Insulation 054747-2018 . Passed Michael Collins Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Completion of demising walls Yes BLDG-Building Deficiency . Partial demising walls Yes BLDG-Building Deficiency Need demising walls No • BLDG-Electric Meter 054748.2018 Passed Michael Collins Complete Release Checklist Item . COMMENTS Passed BLDG-Building Deficiency Release emailed to SDGE Yes 0411312018 0411312018 BLDG-Final 054952-2018 Partial Pass Michael Collins Reinspection Incomplete Inspection June 28,2019 • • Page 3of4 Permit Type: BLDG-Commercial Application Date: 12/01/2017 Owner: R P I CARLSBAD LP Work Class: Tenant Improvement Issue Date: 02/12/2018 Subdivision: CARLSBAD TCT#76-18 Status: Closed - Expired Expiration Date: 11/05/2018 Address: 2525 El Camino Real .216 Carlsbad, CA 92008 IVR Number: 8101 Scheduled Actual Date Inspecti Start Date on Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-Plumbing Final No BLDG-Mechanical Final No BLDG-Structural Final No BLDG-Electrical Final . No 0510112018 0510112018 BLDG-Final 056595-2018 . Failed Michael Collins Reinspection Complete Inspection Checklist Item COMMENTS . Passed BLDG-Building Deficiency Not ready 'No 0510212018 0510212018 BLDG-Final 056794-2018 Partial Pass Michael Collins Reinspection Incomplete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Ok to stock and train. See card for pick up. Yes • BLDG-Building Deficiency Not ready No 0510712018 05/0712018 BLDG-Final 056936-2018 Partial Pass Michael Collins Reinspection Incomplete Inspection - Checklist Item COMMENTS • Passed BLDG-Building Deficiency Ok to stock and train. See card for pick up. Yes BLDG-Building Deficiency Yes BLDG-Building Deficiency Not ready No June 28,2019 Page 4of4 EsGil A SAFEbuiItCompany DATE: 1/18/2018 13 APPLICANT flJURIS. JURISDICTION: Carlsbàdi] PLAN CHECK #.: CBC2017-0630 SET: II PROJECT ADDRESS: 252 El Camino Real #216 PROJECT NAME: Nektar Juice Bar Tenant Improvement LI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. LIII The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by-3) Email: Mail Telephone Fax In Person REMARKS: ClTYll séfprior to perrñifl V By: Jason Pasiut Enclosures: EsGil 6o 1/11/2018 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil A SAFEbuitf Company DATE: 12/12/2017 U APPLICANT )1 URIS. JURISDICTION: Carlsbad PLAN CHECK #.: CBC2017-0630 SET: I PROJECT ADDRESS: 25El Camino Real #216 PROJECT NAME: Nektar Juice Bar Tenant Improvement The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted fora complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. LII The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant. contact person. The applicant's copy of the check list has been sent to: Tamer Gergis EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Tamer Gergis Telephone #: 949-716-9990 4ate co9tacted: fl'( (by: ()J. Email: tamer.gergis@nationaleng.com ,NIaiI lephong Fax In Person LII REMARKS: By: Jason Pasiut Enclosures: EsGil 12/5/2017 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad CBC2017-0630 12/12/2017 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK #.: CBC2017-0630 OCCUPANCY: B TYPE OF CONSTRUCTION: 111-B ALLOWABLE FLOOR AREA: within SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 12/1/2017 DATE INITIAL PLAN REVIEW COMPLETED: 12/12/2017 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad USE: Juice Bar ACTUAL AREA: 999s.f. STORIES: 2 HEIGHT: unchanged OCCUPANT LOAD: 22 DATE PLANS RECEIVED BY ESGIL CORPORATION: 12/5/2017 PLAN REVIEWER: Jason Pasiut This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2016 CBC, which adopts the 2015 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section. etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBC20 17-0630 12/12/2017 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. . PLANS Please update the currents codes in effect to the 2016 California Fire Code. . ENERGY 2. The NRCC-LTI-01-E pages 3-6 does not show the allowed lighting power. Please complete the information after reviewing the comment below. The NRCC-LTI-03-E uses Table 140.6-B to calculate the allowed wattage for restaurants. Table 140.6-B shows an allowance of 1.1 watts per square foot for restaurants. Using the proposed square footage, the allowed watts equals 1,100. The installed wattage shown on the NRC-LTl-01 -E pages 3-6 exceeds 1,100. Please revise. Please show on the NCRR-LTI-02-E, page 2 of 3, all of the proposed lighting controls for each separate space that will be used to reduce the lighting wattage below allowed levels. . PLUMBING The fixture unit count chart on sheet P101 shows 8 (3") floor sinks. There are four shown on the plans with the potential for a fifth one for the walk-in cooler condensate drainage. Please revise fixture count. Show the floor sink for the walk-in cooler condensate or show the drainage to the nearest floor sink next to the water heater. Carlsbad CBC2017-0630 12112/2017 7. Provide details for the primary temperature control, overtemperature safety protection device and/or combination temperature/pressure relief valve. CPC 505.2. 8. Show applicable backflow prevention devices at the water outlets with hose attachment, beverage dispenser, water heater, water closet, and water supply inlets to tanks. CPC 603. . WALK IN COOLER 9. Provide the manufacturer standard plans and installation instructions/listing information for the cooler walls and refrigeration equipment being proposed. CMC 935. Show connection details for corners and roof including fasteners. Show foam thickness and flame-spread information. 10. Show location of indirect drain / floor sink and detail condensate drain pipe size, trap, vent, clean-out requirements per manufacturer, and required airgap. CPC4I8.4, CPC 814. 11. Refrigerated Spaces that are less than 3,000 square feet shall meet the requirements of the Appliance Efficiency Regulations for walk-in coolers or freezers contained in the Appliance Efficiency Regulations (California Code of Regulations, Title 20, Sections 1601 through 1608). Note on the plans whether this installation meets these requirements. CEC 120.6 (a) . END OF REVIEW To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: U Yes U No The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Jason Pasiut at Esgil Corporation. Thank you. Ôarlsbad CBC2017-0630 12/12/2017 [DO NOT PAY— THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK #.: CBC2017-0630 PREPARED BY: Jason Pasiut DATE: 12/12/2017 BUILDING ADDRESS: 252 El Camino Real #216 BUILDING OCCUPANCY: B BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) 999 46.51 46,463 Air Conditioning Fire Sprinklers TOTAL VALUE 46,463 Jurisdiction Code Icb IBY Ordinance I Bldg. Permit Fee by Ordinance v V Plan Check Fee by Ordinance Type of Review: El Complete Review I $387.291 I $251.741 Structural Only El Repetitive Fee I Repeats El Other El Hourly Hr. © * EsGil Fee I $220.761 Comments: Sheet 1 of 1 E IS ELISE ROTHSCHILD Director Countp of batt Otell o DEPARTMENT OF ENVIRONMENTAL HEALTH FOOD AND HOUSING DIVISION P.O. BOX 129261, SAN DIEGO, CA 92112-9261 Phone: (858) 505-6659 FAX: (858)505-6824 1 (800) 253-9933 www.sdcdeh.org RECEIVED AMY HARBERIJAN 1 2 2018 Assistant Director CITY OF CARLSBAD BUILDING DIVISION PLAN APPROVAL SHEET DBA: Nekter Juice Bar SITE: 2525 El Carnino Real 218B, Carlsbad, CA 92008 BUSINESS OWNER: Phil Laclair Plans are approved contingent upon the following: DATE: 1/18/2018 PC #: DEH20I7-FFPP-008990 2) Changes to equipment layout, menu, or application must be submitted, for approval. Changes made without approval will make the 4) All food and utensil-related equipment shall be certified to applicable sanitation standards by an ANSI accredited testing agency. 5) Upon completion of 50%-80% of construction, call (858) 505-6660 to schedule a mid-inspection. In lieu of a plumbing inspection by DEH, ensure that the plumbing is constructed to these standards: Floór sinks shall be installed V2 exposed and equipped with an appropriate grill cover if no access is provided for cleaning. Drain lines shall slope ¼" per foot, shall not exceed 15' in length and shall terminate a minimum of 1" above the floor sink with a legal air gap or otherwise approved by the enforcing agency: Drain lines shall not intersect walkways or door ways. No condensate drainage of any kind can drain to the mop sink. 3-compartment sinks, preparation sinks, dumpsinks, and any other plumbed equipthent must drain indirect to a floor sink. Grease traps/interceptors, if required by the local waste water authority must be located outside of the food preparation, food storage,. or warewáshing areas. Floorsurfaces must be sloped 1:50 to required floor drains. Conduits of alltypes shall be installed within walls as practicable. When otherwise installed, they shall be mounted or enclosed in a chase so as to facilitate cleaning. 6) Owners and/or operators must pass an approved and accredited Food Safety Certification course. Proof of successful completion of this course is to be furnished at the final inspection 7) All equipment is to be in place and functional. At the time when the final inspection is requested, the facility shall have all utilities operational and all refrigeration shall have an ambient air temperature of 38°F or below and shall be equipped with a thermometer accurate to +1- 2°F in the warmest section of the unit. 8) Seal all cracks, gaps and crevices in counters, cabinets, around metal flashing, sink backsplashes, around pipes and conduits with silicone sealant. 9AN AIR BALANCE REPORT IS REQUI FA! YHAS VENTILATiON HOObS1_____________ L.i _-.._-_ • --- . --..--•"-- ----. -.'-.•-•. "•.--", Plans reviewed by: Celeste Penn, REHS & Mickey Lay, EHTo # ENVUO CALL (858) 505-6660 AT LEAST 10 WORKING DAYS IN ADVANCE TO SCHEDULE MID AND FINAL INSPECTIONS A FINAL INSPECTION MUST BE CONDUCTED AND AN ENVIRONMENTAL HEALTH PERMIT SHALL BE ISSUED PRIOR TO OPENING AND OPERATING THIS FOOD ESTABLISHMENT. "Environmental and public health through leadership, partnership and science", AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered sectiorf when made In accordance with the conditions set forth in the Certification Agreement and Listing i Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable.. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: DAE Sri Via Trieste WE Address: 31025 Santa Lucia di Piave (TV) Italia Country: Italy Contact: Mr. Enrico Peccolo Phone: 0039 0438 460883 FAX: 0039 0438 468935 Email: enrico@daeftaly.com Manufacturer: DAE Sri Via Trieste WE Address: 31025 Santa Lucia di Piave (TV) Italia Country: Italy Contact: Mr. Enrico Peccolo Phone: 0039 0438 460883 FAX: 0039 0438 468935 Email: ertricotdaeitaty.com Party Authorized To Apply Mark: Report issuing Office: Control Number: 5001732 Same as Manufacturer UDINE 1- Helth Gusta sson for Thomas-J. Patterson, Certification Manager Authorized by: This document supersedes all previous Authorizations to Mark for the noted Report Number. The Atsthodzatlen to Mark Is for the .xduslve use 01 kiIerteks OIiI arid Is preMed pursuant to the Ctilcedon agreement between tntestek and Its CIISM. I,testeIts responulblllty and gabliity are United to the terms and conetlion of the sgmemanL kit wtek assiasles no liability to any party, otherthen loft Olent In accordance with the agreement, for any low expanse ardamage occasioned by Itre used Oh MlhodzaUcn to Madi. Only the Cilentis authodsed jopemit009)ing or ots ,ibuilon of the Authaeiufton to Mask and then aity In Its entirely. Use Crkutottdis Certification mart Is reskicled totho coniiens laid cut In the agreement and in this agUwAuzeegn to mmit mWumer use dOte kitcrtek name for the sale or advertisaneni of the tested mate", pmduct or service must first be approved In veiling bylnteitek. NOW Factory Usessnianta and Follow up SeMces are for the purpose classuftaPproprialetisage of Use Cesllhicatlon mask In aacordancewlththe agreement they ale not for Ihepteposea of prOductiOn quality osnudi aIM do not rekave the Client dlhairobilgaslons In UsIa respect' Intertek Testing ServIces NA Inc. 545 East Algonqu in Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard(s): Ice Cream Makers. UL 621, Issued: 2010/05/07 Ed: 7 Rev: 2013110/25 Commercial Refrigerators and Freezers, UL 471, Issued: 2010111/24 Ed.: 10 Rev: 2014/11/17 Refrigeration Equipment, CSA C22.2 #120k Issued: 2013/03/01 Ed: 4 Product: Ice cream makers Brand Name: BG Italy Models: INST fib 1,2 or 4, fib 0 or 1, f/b W or blank, fib -UL ')fl%Cfl/\ FM APPROVALS PROJECT ID: 3022512 Product identification Marking LU FM APPROVALS > o SPECIFICATION TESTED PER ASTM E84 TEST M ETHOD W LL PM.APPROVALS PROJECT D3O22S12 LL, > rr nj MASTER-BILT PRODUCTS . MASTER-BILT WALL & CEILING PANELS TESTED WITH FACINGS REMOVED 20-24 lbl& (32-38 kg/t 3) CORE FOAM DENSITY ASTM E84-03 FIRE TEST RESULTS 4in (100 mm) thick Flame Spread Index 25 Smoke Developed Index 400 AIM .: : . ,. ... .. . THESE NUMERICAL VALUES ARE NOT INTENDED TO REFLECT HAZARDS . PRESENTED BY THIS MATERIAL UNDER ACTUAL FIRE CONDITIONS.' FM APPROVALS AUDIT INSPECTION AND RE-EXAMINATION PROGRAM RELATES ONLY TO THE ABOVE. MB MASTER BILT® TM Refrigeration Solutions Walk-In Coolers and Freeze Installation & Operations Man I < 4 ( 11 -z °L -' f. Ca 908 Highway 15 North • New Albany, MS 38652 • Phone: (800) 684-8988 • Fax: (800) 232-3966 Email: service@master-bilt.com c6c4VA011=0 O(i 3O TABLE OF CONTENTS INTRODUCTION •3 WARNING LABELS AND SAFETY INSTRUCTIONS................................................................4 PRE-ASSEMBLY PROCEDURES ............................................................................. ................. 7 Inspection.............................. .......................... ....... ............................................................................... ..............7 Handlingand Set-Up Precautions.......................................................................................................................7 PanelStorage .....................................................................................................................................................8 ASSEMBLY INSTRUCTIONS.....................................................................................................9 CamFasteners .................................................................................................................................................... 9 Ceilp.g and Wall Clearances.............................................................................................................................10 Lelingthe Floor..............................................................................................................................................11 Fking; installation ........................................................................................................................................... 11 Walland Ceiling Assembly................................................................................................................................12 Doorand Frame Installation..............................................................................................................................12 Caulking.............................................................................................................................................................13 SERVICINGPROCEDURES.....................................................................................................14 Adjusting Door and Replacing Hinges ..............................................................................................................14 Cooler Door Frame Heater Replacement .........................................................................................................15 FreezerDoor Heater Repair..............................................................................................................................15 CLEANINGPROCEDURES .....................................................................................................18 FreezerCleaning ............................................................................................................................................... 18 CoolerCleaning ................................................................................................................................................18 SALEAND DISPOSAL.............................................................................................................19 PANEL AND DOOR DESIGNATIONS......................................................................................20 PanelDesignation Legend................................................................................................................................20 Door& Frame Designation Legend...................................................................................................................21 145;h> CITY OF CARLSBAD PLUMBING, ELECTRICAL, MECHANICAL WORKSHEET B-18 Development Services Building Division 1635 Faraday Avenue 760-602-2719 REC"-' WwwcarIsbadca.gov Buildingccarlsbadca.gov bb LI tamino Meal, Project Address: Space #21 8B, Permit No.: CITY OF CA}<LSBAD Carlsbad, CA 92008 BUILDING DIVISION Information provided below refers to work being done on the above mentioned permit only. This form must be completed and returned to the Building Division before the permit can be issued. - Building Dept. Fax: (760) 602-8558 Number of new or relocated fixtures, traps, or floor drains 14 Newbuilding sewer line? .........................................................................................YesX No Numberof new roof drains? ............................................................................................................... 0 Install/alter water line? ......................................................................................................................... 1 Number of new water heaters? ......................................................................................................... 1 Number of new, relocated or replaced gas outlets? .................................................................... 0 Number of new hose bibs? .................................................................................................................. 0 Residential Permits: New/expanded service: Number of new amps: Minor Remodel only, Yes No Commercial/Industrial: Tenant Improvement: Number of existing amps in valved in this Number of new amps involved in this New Construction: Amps per Panel: SinglePhase ...............................................................Number of new amperes ThreePhase ...... ...........?9P...... .................................. Number of new amperes 127 Three Phase 480........................................................Number of new amperes_______________ Number of new furnaces, A/C, or heat pumps? ............................................................................ 0 New or relocated duct work? .......................................................................... Yes X No_____ Numberof new fireplaces? ................................................................................................................. 0 Number of new exhaust fans? ............................................................................................................ 2 Relocate/install went? ............................................................................................................................ X Numberof new exhaust hoods? ........................................................................................................ 0 Numberof new boilers or compressors? ........................................................... Number of HP 0 B-18 Page 1 of 1 Rev. 03/09