HomeMy WebLinkAbout2525 El Camino Real; 102; CBC2018-0146; Permit{city of
Carlsbad
Print Date: 09/26/2018
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
2525 El Camino Real, 102
BLDG-Commercial
1563020900
$6,656.00
Commercial Permit
Work Class: Tenant Improvement
Lot#:
Reference#:
Construction Type:
Bathrooms:
Orig. Plan Check#:
Plan Check#:
Description: THE SHOPPES: OWNER SHELL WORK· NEW STOREFRONT-APPROX 90 LF
Applicant:
SEAN HARRIS
3500 W Burbank Blvd
Burbank, CA 91505-2235
818-972-5080
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
Owner:
R PI CARLS8AD LP
1114 Avenue Of The Americas, Floor 45
New York, NY 10036-7700
214-660-5232 x215232
ELECTRICAL BLDG COMMERCIAL NEW/AOOITION/REMOOEL
5B1473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-COMMERCIAL
Total Fees: $194.05 Total Payments To Date: $194.05
Status:
Applied:
Issued:
Permit
Finaled:
Inspector:
Final
Inspection:
Balance Due:
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Permit No: CBC2018-0146
Closed -Finaled
03/16/2018
04/11/2018
MColl
9/26/2018 10:42:52AM
$0.00
$88.35
$61.84
$41.00
$1.00
$1.86
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 I I www.carlsbadca.gov
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: □PLANNING □ENGINEERING □BUILDING □FIRE □HEALTH □HAZMATIAPCD I
( City of Bulldlng Permit Appllcatlon Plan Check No. ~Z() Ii-0 I Y\..t'
1635 Faraday Ave., Carlsbad, CA 92008 Est. Value lo,L,Q5lo
Carlsbad Ph: 760-602-2719 Fax: 760-602-8558 .
email: building@cartsbadca.gov Plan Ck. Deposit
www.carlsbadca.gov Date ~ ~ -ll , -/'i!'I03.15.18
JOB ADDRESS SUITE•JSPACEf/UNITI
I""" 2525 El Camino Real 1n2. 156 -302 -08 -
CT/PROJECT# I LOT# I PHASE# I# OF UNITS I# BEDROOMS # BATHROOMS
ITE"';~:s;;;~s at Carlsbad I CON;~,:;' I occ ;OUP
DESCRIPTION OF WORK: Include Square Feet of AffMted' Alu(•)
TENANT IMPROVEMENT SHELL WORK FOR SPACE #illarr. 1oz.
PROVIDING NEW STOREFRONT AND CONDUIT FOR FOR FUTURE TENANT INTERIOR SIGNAGE.
C\O LF cl' loto'("Q__tj°Of\-\-
EXISTING USE I PROPOSED USE I GARAGE (SF) PATIOS {SF) I DECKS {SF) FIREPLACE I AIR CONDITIONING I FIRE SPRINKLERS
Retail Mall Retail Mall vesO, Ncf!J ves[2]No□ YES[2)No□
APPLICANT NAME Sean Harris, LOA Desian Group PROPERTY OWNER NAME Kyle Godat, Rouse Properties 3 WAY·.&PElMll
ADDRESS ADDRESS
3500 W Burbank Blvd 555 Broadway Suite 1019
CllY STATE ZIP CllY STATE ZIP Burbank CA 91505 Chula Vista CA 91910
PHONE rAX PHONE l'AX 818-972-5080 619-427-6701
EMAIL EMAIL
seanh ldadesigngroup.com kyle.godat@rouseproperties.com
DESIGN PROFESSIONAL CONTRACTOR BUS. NAME Donald D. Linane AIA Rob Prather Whitina Turner Contractina Co
ADDRESS ADDRESS
3500 W. Burbank Blvd 250 Commerce Street, Suite 150
CITY STATE ZIP CllY STATE ZIP
Burbank CA 91505 Irvine CA 92602
PHONE IFAX PHONE IFAX 818-972-5080 818-848-3895 949-863-0800
EMAIL EMAIL donl@ldadesigngroup.com Rob.Prather@whiting-turner.com
I STATE LICC-18772 STATE LIC.# ICL>SS I CITY BUS. UC.#
(Sec. 7031.5 Busmess and Professions Code: Any City or County which requires a pemut to construct, alter, improve, demolish or repair an:,-structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of tne Contractor's license Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exemr,t therefrom, and the basis for the alleged exemption. Any violation of Section 1031.5 by any applicanf"for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500)).
WORKERS' COMPENSATION
Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declarations: D I have and will maintain a certificate of conHnt to self-lnture for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this pennit is issued. D I have and will maintain workers' compenutlon, as reQUired bv Section 3700 of the Labor Code, fer the performance of the work for which this pennit is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co. __________________ Policy No. ____________ Expiration Date _______ _
l!li§.section need not be completed if the pennit is for one hundred dollars ($100) or less.
LJ Certificate or Exemption: I certify that In the perfonnance of the work for which this pennit is Issued, I shall not employ any person in any manner so as lo become subject lo the Won<ers' CompensaUon Laws of
California. WARNING: Failure lo secure workers' tomfN1naatlon coverage 11 unlawful, and shall subject an employer lo criminal penalties and dvll fines up lo one hundred thousand dollars (&100,000), In
addition lo the cost of compensation, damages as provided for In Section 3708 of the Labor code, Interest and attomey's fees.
,I!, CONTRACTOR SIGNATURE □AGENT DATE
OWNER-BUILDER DECLARATION
f hereby aftinn that I am exempt from Contractor's License Law for the following reason:
~ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale {Sec. 7044, Business and Professions Code: The Contractor"s
□
□
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for Iha purpose of sale).
I, as owner of1he property, am exdusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds°' improves thereon, and contracts for such projects with contrector(s) licensed pursuant lo the Contractor's License Law).
I am exempt under Section ____ ,Business and Professions Code for this reason:
1. I personally plan to provide lhe majOf' labor and materials for construction of the proposed property improvement 0Yes Oo
2. t (have/ have not) signed an application for a building permit fOf' the proposed work.
3. I have contracted with the following person (finn) lo provide the proposed construction Ondude name address/ phone/ contractors' license number):
4. I plan lo provide portions of the work, but I have hired the foll"""""'""" to coordinate, supervise and provide lhe majOf' work Ondude name I address/ phona / contractors' license number):
5. I 'MIi provide some of the work, but I have contracted ) the fol persons to provide Iha work indicated (lndude name I address / phone / type of work):
,I!, PROPERlY OWNER SIGNATUR DATE
PERMIT INSPECTION HISTORY REPORT (CBC2018-0146)
Permit Type: BLDG-Commercial Application Date: 03/16/2018 Owner: R P I CARLSBAD LP
Work Class: Tenant Improvement Issue Date: 04/11/2018 Subdivision: CARLSBAD TCT#76-18
Status: Closed -Finaled Expiration Date: 03/18/2019 Address: 2525 El Camino Real , 102
Carlsbad, CA 92008-1206
IVR Number: 10176
Scheduled Actual Primary Inspector Reinspection
Date Start Date Inspection Type Inspection No. Inspection Status Complete
04/23/2018 04/23/2018 BLDG-14 055737-2018 Partial Pass Paul Burnette Relnspection Incomplete
Frame/Steel/Bolting/
Welding {Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-34 Rough 055736-2018 Partial Pass Paul Burnette Reinspectlon Incomplete
Electrical
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
04/27/2018 04/27/2018 BLDG-17 Interior 056371-2018 Passed Michael Collins Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency DenGlass at storefront & columns. Yes
05/31/2018 0513112018 BLDG-Final 059640-2018 Partial Pass Michael Collins Reinspection Incomplete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency See card Yes
BLDG-Electrical Final Yes
08/16/2018 08/16/2018 BLDG-15 067267-2018 Partial Pass Michael Collins Reinspection Incomplete
Roof/ReRoof (Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Pre lim roof curb frame Yes
08/20/2018 08/20/2018 BLDG-14 067380-2018 Passed Michael Collins Complete
Frame/Steel/Bolting/
Weldlng (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency HVAC roof curbs & roof structure framing Yes
09/17/2018 09/17/2018 BLDG-34 Rough 070029-2018 Partial Pass Paul Burnette Reinspection Incomplete
Electrical
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
09126/2018 09/26/2018 BLDG-Flnal 071280-2018 Passed Paul Burnette Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency See card Yes
BLDG-Electrical Final Yes
September 26, 2018 Page 1 of 1
✓• EsG1I
A SAFEbuilt Cornpary
DATE: 3/26/2017
JURISDICTION: Carlsbad
□ APPLICANT
□ JURIS.
PLAN CHECK#.: CBC2018-0146 SET: I
PROJECT ADDRESS: 2525 El Camino REAL #102
PROJECT NAME: Forever 21 Storefront Tenant Improvement
□
□
□
□
□
~
□
□
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise th7'applicant that the plan check has been completed.
Person contacted·// JID Telephone#:
Date contacted: (by:~) Email:
Mail Telephone Fax In Person
REMARKS:
By: Jason Pasiut
EsGil
3/20/2018
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad CBC2018-0146
3/26/2017
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Jason Pasiut
PLAN CHECK#.: CBC2018-0146
DATE: 3/26/2017
BUILDING ADDRESS: 2525 El Camino REAL #102
BUILDING OCCUPANCY: M
BUILDING AREA Valuation Reg.
PORTION (Sq.Ft.) Multiplier Mod.
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
1997 UBC Plan Check Fee ... ---~
Type of Review: 0 Complete Review
VALUE
D Structural Only
0 Repetitive Fee •. =~] Repeats
D Other
D Hourly
EsGil Fee 1-------ll Hr. @ *
Comments:
($)
6,656
6,656
$87.981
$57.191
$50.151
Sheet 1 of 1
SCHROEDER
Construction & Development, Inc
November 8, 2018
City of Carlsbad, Building Department
1635 Faraday Ave
Carlsbad, CA 92008
Attn: Mike Petersen
Dear City of Carlsbad:
Schroeder Construction & Development Inc was contracted by Rouse Properties to construct the storefront only
for the future Forever 21 space. The permit information is:
CBC 2018-0146
2525 El Camino Real #102
Description: The Shoppes: owner shell work-new storefront 3/16/2018
At some time after this work was completed, Rouse Properties contracted with Deacon Construction to do
additional structural reinforcement on the 2"' floor for Forever 21's RTU's. While we were not involved in this work
what so ever, Deacon processed plans and added this work to my permit without my knowledge.
Since we were not involved with this work, I talked to Mike Petersen to see if this work could be separated onto a
separate permit. Mike said it was too late for that, but suggested I write a letter to the City explaining this
situation. That is the purpose of this letter. Can you please keep this in the job file for the permit referenced above,
so it is clear in the future that Schroeder Construction & Development Inc was not involved or responsible for this
additional work performed by Deacon Construction.
~
Thomas Schroeder
Schroeder Construction & Development Inc
2695 State Street
Carlsbad CA 92008
760-434-4396
Print Date: 01/04/2019
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
2525 El Camino Real, 102
BLDG-Permit Revision
1563020900
$ 0.00
Revision Permit
Work Class: Residential Permit Revisi
Lot#:
Reference #:
Construction Type
Bathrooms:
Orig. Plan Check#: CBC2018-0146
Plan Check#:
(city of
Carlsbad
Permit No: PREV2018-0180
Status: Closed -Finaled
Applied: 06/29/2018
Issued: 08/08/2018
Permit 01/04/2019 Finaled:
Inspector: MColl
Final
Inspection:
Description: THE SHOPPES: PROVIDE EQUIPMENT PLATFORM AND STRUCTURAL REINFORCEMENT TO EXISTING ROOF
Applicant:
SEAN HARRIS
3500 W Burbank Blvd
Burbank, CA 91505-2235
818-972-5080
FEE
BUILDING PLAN CHECK ADMIN FEE
MANUAL BUILDING PLAN CHECK FEE
Total Fees: $ 147.50
Building Division
Owner:
R P I CARLSBAD LP
1114 Avenue OfThe Americas, Floor 45
New York, NY 10036-7700
214-660-5232 x215232
Total Payments To Date : $ 147.50 Balance Due:
AMOUNT
$35.00
$112.50
$0.00
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
{cicyof
Carlsbad
PLAN CHECK REVISION OR
DEFERRED SUBMITTAL
APPLICATION
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov B-15
Original Plan Check Number C [3 ( J.()1-3° -o/q (q
Project Address ;},!j'J,5 8 l 4m•YJO ~a,.)
Plan Revision Number fK.c't.LdbL~ d J f:6
General Scope of Revision/Deferred Submittal:Fl ,~V!~o..,,111...,J""cC---f&:<1,Q.(i;.,llcµO""m"",?""11'--'-+--ol,,,0!£....,_.,..,,,,,"""-,f'l__,,4'---kJ--LL"il«<Cctl_..,.,.i,;a"'-"--I __ ~ '1,,1 ' -tl
fC11tJlovcewievit ±0 ex:1-A,'4j woP,
CONTACT INFORMATION:
Name f11Lcbu.: / Cv.Vh";i Phone Fax,__ _______ _
Address 3500 \,,[c.5} Bwb@k B111J.. City Rur~lil k Zip q 1505
Email Address V\1t cha.elc@frla dc5(fjVCl'lf C/1.Wl
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person.
1 . Elements revised: lKJ Plans iz5l Calculations D Soils D Energy D Other
2.
Describe revisions in detail
3.
List page(s) where each
revision is shown
4. Does this revision, in any way, alter the exterior of the project? D Yes [81 No
5. Does this revision add ANY new floor areals)? D Yes
6. Does this revision affect any fire related issues? D Yes
7. Is this a complete set? Qg Yes D No
~Signature~ {j;f/;:
IZl No
EJ No
Date G /,2 {/ /~
1635 Faraday Avenue, Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: building@carlsbadca.gov
www.carlsbadca.gov
✓• EsG1I
A SAFEbuilt'Company
DATE: 7/9/2018
JURISDICTION: Carlsbad
PLAN CHECK#.: CBC2018-0146.rev
PROJECT ADDRESS: 2525 El Camino Real
PROJECT NAME: Forever 21 Revision
SET: I
g,_APPLICANT /CJ JURIS.
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
~ EsGil staff did not advise the applicant that the plan check has been completed.
D EsGil staff did advise the applicant that the plan check has been completed.
Person contacted· --n D Telephone#:
Date contacted: -{w ) Email:
Mail Telephone Fax In Person
~ REMARKS: PREV2018-0180
By: Jason Pasiut
EsGil
7/2/2018
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Car'Isbad CBC2018-0146.rev
7/9/2018
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK#.: CBC2018-0146.rev
PREPARED BY: Jason Pasiut
BUILDING ADDRESS: 2525 El Camino Real
BUILDING OCCUPANCY: M
BUILDING AREA Valuation
PORTION ( Sq. Ft.) Multiplier
Hourlv review
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code #N/A
1997 UBC Building Permit Fee ...
1997 UBC Plan Check Fee ...
Type of Review: □ Complete Review
DATE: 7/9/2018
Reg. VALUE
Mod.
D Structural Only
D Repetitive Fee
...,. Repeats
D Other
0 Hourly
EsGII Fee
11Hr.@• ~=====$=9=□=-o~o
* Based on hourly rate
Comments:
($)
$90.001
Sheet 1 of 1
~,, LDA
des,gn grouo
JUN 2 9 2018
CITY or: Ci'::,'.',,'. °siJ
BUILD\(,;G L:·;/·1.·',~:• ;·.j
Narrative
Date: June 28, 2018
Project Number: RP1603.55
Project Name:
Project Location:
Bulletin No.:
The Shoppes at Carlsbad
Forever 21
Carlsbad, CA
1
The follmving changes, deletions, additions, additions, and / or alterations in, on and to the
drawings and specifications shall apply to proposals made for and to the execution of the various
parts of the work affected thereby.
Careful note of this Bulletin shall be taken by all parties of interest so that the proper allowance
may be made in all computations, estimates and contracts, and all trades affected shall be fully
advised in the performance of the work which will be required of them.
This Bulletin supersedes all previous drawings, specifications, and instructions pertaining to the
items of work herein.
In case of conflict between drawings, specifications, and this Bulletin, the architect shall determine
what governs.
Description of Builetin Items
Added scope: ,.
Provide equipment platform and structural reinforcement to existing roof for future tenant RTUs. Ii-•
ARCHITECTURAL: \J
Mill
• Revised the sheet index to include "Roof Plan" in the tittle of A2.l
• Added a Structural section to the sheet index
A2.l:
• Added a roof plan to reflect the location of future rooftop units by tenants
• Added roof details
• Added a site line diagram
STRUCTURAL:
Added a structural documents and calculations for the retrofit of the existing roof structure.
End of Narrative
3500 West Burbank Boulevard, Burbank, California 91505 T: 818-972-5080 F: 818-8-3895 www.LDAeslgngroup
.:.~r LDA
Date:
Project Number:
Project Name:
Project Location:
Addendum No.:
Narrative
April 03, 2018
RP1603.55
The Shoppes at Carlsbad
Space 102 F21 Storefront
Carlsbad, CA
A
The fol1owing changes, deletions, additions, additions, and / or alterations in, on and to the drawings and specifications
shall apply to proposals made for and to the execution of the various parts of the \'\-'Ork affected thereby.
Careful note of this Addendum shall be taken by all parties of interest so that the proper allowance may be made in all
computations, estimates and contracts, and all trades affected shall be fully advised in the performance of the work which
,vm be required of them.
'Ibis Addendum supersedes all previous drmvings, specifications, and instructions pertaining to the items of work herein.
In case of conflict between drawings, specifications, and this Addendum, the architect shall determine what governs.
Description of Addendum 'C' Items
AM
1. Identified issued sheets on sheet index
Clarified Notes to provide second mobilization for an interior storefront finishes
A3.l : Details 3, 4, & 5
A4.l : Section 3
A7.l : Details 11, 14, & 15
Encl of Narrative
3500 West Burbank Boulevard, Burbank, California 91505 T: 818-972-5080 F: 818-848-3895 www.LDAdesigngroup.com
Thornton Tomasetti
Building Solutions
Project
The Shoppes at Carlsbad
Space 102 Structural Calculations
Project No. S16012.54
Prepared For
LOA Design Group
3500 West Burbank Blvd.
Burbank, CA 91505
T: 818.972.5080
Prepared By
Thornton Tomasetti Inc.
925 Fort Stockton Drive. Suite 200
San Diego, CA 92103
T: 619.550.5900
June 28, 2018
Brookfieldj
Properties \
PREV2018-0180
2525 EL CAMINO REAL # 102
THE SHOPPES: PROVIDE EQUIPMENT PLATFORM AND
STRUCTURAL REINFORCEMENT TO EXISTING ROOF
CBC2018-0146
1563020900
6/29/2018
PREV2018-0180
Thornton Tomasetti
TABLE OF CONTENTS
Calculatlons
Design Criteria
Gravity Loading .................................................................................................................... A1-1
Lateral Loading ..................................................................................................................... A2.-1
Mlscellaneous
RTU Framing ....................................................................................................................... M1-1
Space 102 Structural Calculations June 28, 2018 I Project# S16012.54
Thornton Tomasetti
Building Solutions
Section A
Design Criteria
' .
Thornton Tomasetti
Building Solutions
Al -Gravity Loading
A1-1
·---···~--
• Thornton Tomasetti
ProJect The Shoeees at Carlsbad ProJect No. S16012 Date 6/25/2018
!f AB Sheet of
SubJHt Building Loads Chec:11:ed!f TT Drawing No.
Minimum Design Loads
CBC 2013//BC 2012/ ASCE 7-10
1 -Level 2 -!El Lease Area Gravi~ Mass 2 -Level 2 -!El Concourse Gravi~ Mass
Finish 5.0 psf 5.0 psf 2" NWT Topping 25.0 psf 25.0 psf
2 1/2" NWT Cone. Slab 32.0 psf 32.0 psf 2 1/2" NWT Cone. Slab 32.0 psf 32.0 psf
6"x18" NWT Cone. Jst. @ 36"oc 38.0 psf 38.0 psf 6"x18" NWT Cone. Jst. @ 36"oc 38.0 psf 38.0 psf
NWT Cone. Beams 25.0 psf 25.0 psf NWT Cone. Beams 25.0 psf 25.0 psf
NWT Cone. Col's 5.0 psf 5.0 psf NWT Cone. Col's 5.0 psf 5.0 psf
M.E.P. 4.0 psf 4.0 psf M.E.P. 4.0 psf 4.0 psf
Ceiling 3.0 psf 3.0 psf Ceiling 13.0 psf 13.0 psf
Partition 0.0 psf 10.0 psf Partition 0.0 psf 10.0 psf
Misc. 3.0 esf 3.0 est Misc. 3.0 est 3.0 est
DL= 115psf 125 psf DL = 145 psf 155 psf
Retail LL= 75 psf Public LL= 100 psf
3 -Level 2 -!El Exterior Ent!}'. Gravi~ Mass 4 • Level 2 -jE) Exterior Road Gravi~ Mass
3" NWT Topping Slab 40.0 psf 40.0 psf 6" NWT Topping Slab 75.0 psf 75.0 psf
2 1 /2" NWT Cone. Slab 32.0 psf 32.0 psf 41/2" NWT Cone. Slab 56.0 psf 56.0 psf
6"x18" NWT Cone. Jst. @ 36"oe 38.0 psf 38.0 psf 10"x18" NWT Cone. Jst. @40"oe 56.0 psf 56.0 psf
NWT Cone. Beams 25.0 psf 25.0 psf NWT Cone. Beams 30.0 psf 30.0 psf
NWT Cone. Col's 5.0 psf 5.0 psf NWT Cone. Col's 5.0 psf 5.0 psf
M.E.P. 4.0 psf 4.0 psf M.E.P. 4.0 psf 4.0 psf
Ceiling 3.0 psf 3.0 psf Ceiling 3.0 psf 3.0 psf
Partition 0.0 psf 10.0 psf Partition o.o psf 10.0 psf
Misc. 3.0 est 3.0 esf Misc. 3.0 est 3.0 est
DL = 150 psf 160 psf DL = 232 psf 242 psf
Public LL= 100 psf Sidewalk LL= 250 psf
5 -Roof -!El Lease Area Gravi~ Mass 6 -Roof -!El Concourse Gravi~ Mass
Composite Roof 4.0 psf 4.0 psf Composite Roof 4.0 psf 4.0 psf
1 /2" Plywood Sheathing 3.0 psf 3.0 psf 1 /2" Plywood Sheathing 3.0 psf 3.0 psf
3x14 Rafters@ 24" oc 5.0 psf 5.0 psf 3x14 Rafters@ 24" oc 5.0 psf 5.0 psf
Stl. Beam & Col Framing 4.0 psf 4.0 psf Sil. Beam & Col Framing 4.0 psf 4.0 psf
M.E.P. 4.0 psf 4.0 psf M.E.P. 4.0 psf 4.0 psf
Ceiling 3.0 psf 3.0 psf Ceiling 13.0 psf 13.0 psf
Partition 0.0 psf 5.0 psf Partition 0.0 psf 5.0 psf
Misc. 2.0 esf 2.0 est Misc. 2.0 est 2.0 est
DL = 25 psf 30 psf DL = 35 psf 40 psf
Roof LL= 20 psf Roof LL= 20 psf
A1-2
Thornton Tomasetti
Project The Shoppes at Carlsbad
Sull)ect Building Loads
Minimum Design Loads
CBC 2013//BC 2012/ ASCE 7-10
7 -Level 2 • jN} In-fill Gravi~
Finish 5.0 psf
3-1/2" NWC Fill 54.5 psf
2", 18 Ga Metal Deck 2.5 psf
Steel Framing 10.0 psf
M.E.P. 4.0 psf
Ceiling 3.0 psf
Partition 0.0 psf
Misc. 3.0 psf
DL = 82 psf
Retail LL= 100 psf
9 • Level 2 • {Nl Loading Dock Gravi~
7-1/2" (avg) NWC Topping 95.0 psf
4-1/2" NWC Fill 72.5 psf
3", 18 Ga Metal Deck 2.5 psf
Steel Framing 10.0 psf
M.E.P. 4.0 psf
Ceiling 3.0 psf
Partition 0.0 psf
Misc. 3.0 psf
DL = 190 psf
Loading Dock LL= 250 psf
11 • CanOP)'. • IN} T):elcal Gravi~
Composite Roof 5.0 psf
1-1/2", 18 Ga Metal Deck 1.5 psf
Steel Framing 10.0 psf
Misc. 3.0 psf
DL = 20 psf
Roof LL= 20 psf
Mass
5.0 psf
54.5 psf
2.5 psf
10.0 psf
4.0 psf
3.0 psf
10.0 psf
3.0 psf
92 psf
Mass
95.0 psf
72.5 psf
2.5 psf
10.0 psf
4.0 psf
3.0 psf
10.0 psf
3.0 psf
200 psf
Mass
5.0 psf
1.5 psf
10.0 psf
3.0 psf
20 psf
Project No. S16012 Date 6/25/2018
ByAB Sheet of
Checked By TT Drawing No.
8 • Level 2 • {Nl Restaurant Gravi~ Mass
Finish 5.0 psf 5.0 psf
2 1/2" NWT Cone. Slab 32.0 psf 32.0 psf
6"x18" NWT Cone. Jst. @ 36"oc 38.0 psf 38.0 psf
NWT Cone. Beams 25.0 psf 25.0 psf
NWT Cone. Col's 5.0 psf 5.0 psf
M.E.P. 4.0 psf 4.0 psf
Ceiling 3.0 psf 3.0 psf
Partition 0.0 psf 10.0 psf
Misc. 3.0 psf 3.0 psf
DL = 115 psf 125 psf
Dining LL= 100 psf
10 • Roof • IN} T):plcal Gravi~ Mass
Composite Roof 5.0 psf 5.0 psf
1-1/2", 18 Ga Metal Deck 1.5 psf 1.5 psf
Steel Framing 10.0 psf 10.0 psf
M.E.P. 4.0 psf 4.0 psf
Ceiling 3.0 psf 3.0 psf
Partition 0.0 psf 5.0 psf
Misc. 3.0 psf 3.0 psf
DL = 27 psf 32 psf
Roof LL= 20 psf
12 -Mezzanine Gravi~ Mass
2-1/2" LWC Fill 32.1 psf 32.1 psf
2", 18 Ga Metal Deck 2.5 psf 2.5 psf
Steel Framing 10.0 psf 10.0 psf
M.E.P. 4.0 psf 4.0 psf
Ceiling 3.0 psf 3.0 psf
Misc. 3.0 psf 3.0 psf
DL = 55 psf 55 psf
Mezzanine LL= 125 psf
A1-3
.. '
Thornton Tomasetti
Building Solutions
A2 -Lateral Loading
A2-1
Seismic Parameters
Seismic lnportance Factor, I, 1.0
Occupancy Category II
Site Class D
Seismic Design Category D
s, 1.111g
s, 0.428g
Sos 0.782g
So, 0.448g
A2-2
Thornton Tomasetti
Building Solutions
Section M
Miscellaneous
•
Thornton Tomasetti
Building Solutions
Ml -RTU Framing
MH
Non-Structural Seismic Loading
ASCE 7-10, Chapter 13
Description:
Detennine F P for roof mounted HVAC equipment.
Component Type: HVAC (Conservative Envelope)
Seimic Coefficients:
Additional Input
Importance Factor
Spectral Acceleration,
Short Period
Component Operating
Weight
Height at Point of Attachment
Average Roof Height
Detennine Seismic Design Force
04·a...·Sos·W ( \
Fp(wp) := · v ~ P. 1 + 2 .. ~j
1i,
Fp_max(wp) := l.6-Sos·1i,·Wp
Fp_min(wp) := 0.3·Sos·1i,·Wp
Controlling Design Force
"p := I
I ~ := 22
I n0 := 2-
2
1i, := 1.00
Sos:= o.1s2
z := 41ft
h:= 41ft
Fp_max(wp) ➔ l.25-WP
Fp_min(wp) ➔ 0.23·Wp
[ASCE 7-10 Table 13.6-1]
[ASCE 7-10 Eqn. (13.1-1)]
[ASCE 7-10 Eqn. (13.1-2)]
[ASCE 7-10 Eqn. (13.1-2)]
M1-2
Thornton Tomasetti
PROJECT f;,.,. .., c: c z {
SUBJECT IZ T \) ~
Co.,. J. u,.,, ·, + C? r---z 1
t . F=i> ~ ~
\....~.s·
' A *
4 Z'' T
"' ,\' II
Cc~,,,-,er K-e.c.,,-l:c,.,,5
t) = 7G5 -ff; /4
=-1'7 / #=t"
E _ :!.(?"l I t!){-.,"l. 5 •)
-2' (A 2' ·•)
PRoJEcTNo. s li;o1:z DATE G/?0/1@,
SHEET
CHECKED BY DRAWING NO.
A ss<-->....,e · \7'' C~;,~
Fp" o.~9 \c)f>
:: 0-3'6 (°';:/G,5 .:fJ)
7 '1 ( 4=1-
of I
Cf 2-tvtA "'01 1...c i": (o.c..-o.c-~t>'>)t> +l-
"-0. l -4-4 1>-t c
(z9 ( 4t) (~-4.S ·-')-o."¥1-4 (7GS 4f)(•u')-T ( 42··> 0
T<Q
'l: I ZO :tl-t
M1-3
Thornton Tomasetti
PROJECT ri:3r,,;, ,,., 7, PROJECT NO. SIC,(', I Z DATE (,. /n 1i~
BY S~N SHEET I of f
SUBJECT K1 v ~)-"\ CHECKED BY DRAWING NO.
" I @ ?' 0,C,
?7 '-0"
r-: i:=--L (-z •\(--r: 7·') ( O .0 r 1 kJ-1) -/,\~ l: 'f>
L, {,•)(2-.,·)(0 .On: l.s·r)
().G~ I.: r>
\/ l ~' ,, .. I
L;. ('
C =
i; r ~ -z' ·o.c. i 1", ~ 1>1..,,---'>-'{t,
f . 'i
I>-,-#-,--
!Cl'., vL:-7-:"'43 /.1? ---..
-::::::-~ { L,, 3,.-¼, C.; ~-7,_,..,_, c-c. le
E ~ o.44 l; r J
~ i;:> C. " ( ~?, ) ( c -=,, ) (c,.r-,~ ( l. ,.-( )
G.zA L:p-
L, = (~' )(z,---~/) ( G . Ci I C: c~-r: ,)
3,.,% '· :,:,
17,4~ _.,,. s~-e.. A~.,-~
M1-4
BEAM KEYPLAN
3) 16B26 -E4 TO E5 4
4) EXISTING STEEL COL
'l-,r
2) 14B22 -E5 TO E6~ TYP
( E) . ~{E)1482~ --, TYP
\ / I cu I I I cu I
\,11 .1 \2'1 1 I I \ 1 I 765LBS MAX I l765LBS
1) TYP RTU SUPPORT BM
;' D )-
\_ _/
I {2~2x14
-r;,j ;----l.!!!."--lffu,,o----;,,: ,----:r-"'ll'-,);".,,-,°',---o,-: ~ -
r,.,, W12X16
CD~~?! PARTIAL FRAMING PLAN
M1-5
Wood Beam 4ndows.lhomtontomasetll.corn~lleSye\CA2V'rojec11\S5SY5F-B\Analysis\SEV1'1N-KIFZ178C-•ITH1R2Z-N.EC6
ENERCALC, INC.1983-2017, Blld:10.17.8.9, Ver:10.17.8.9
I, I II I
Description : 1) TYP RTIJ Support Beam
CODE REFERENCES
Calculations per NOS 2012, IBC 2012, CBC 2013, ASCE 7-10
Load Combination Set : ASCE 7-10
Material Pro ertles
Analysis Method : Load Resistance Factor D
Load Combination :ASCE 7-1 O
Fb+
Fb -
1,000.0psi
1,000.0psi
1,500.0psi
E : Modulus of Elasticity
Wood Species : Douglas Fir -Larch
Wood Grade : No.1
Fc -Pr11
Fe -Perp
Fv
Ft
Beam Bracing : Beam is Fully Braced against lateral-torsional buckling
D(0.191 E(0.12) D(0.191 E(0.12)
2-2x14
Span = 27 .0 ft
625.0psi
180.0psi
675.0 psi
Ebend-xx 1,700.0 ksi
Eminbend -xx 620.0ksi
Density 31 .20pcf
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Point Load : D = 0.1910, E = 0.120 k @ 0.0 fl, (RTU Reaction)
Point Load : D = 0.1910, E = 0.120 k@7.750 fl, (RTU Reaction)
DESIGN SUMMARY
Maximum Bending Stress Ratio = 0.279 1 Maximum Shear Stress Ratio
Section used for this span 2-2x14 Section used for this span
fb : Actual = 324.90psi fv : Actual
FB : Allowable = 1, 165.86 psi Fv : Allowable
Load Combination +1.40D+1.60H Load Combination
Location of maximum on span = 7.785ft Location of maximum on span
Span # where maximum occurs = Span# 1 Span # where maximum occurs
Maximum Deflection
Max Downward Transient Deflection 0.067 in Ratio= 4817 >=240.
Max Upward Transient Deflection -0.067 in Ratio= 4817 >=240.
Max Downward Total Deflection 0.258 in Ratio= 1255 >=180
Max Upward Total Deflection 0.000 in Ratio= 0<180
Maximum Forces & Stresses for Load Combinations
Load Combination Max Stress Ratios Moment Values
Segment Length Span# M V A. CFN Ci Cr Cm C t CL Mu lb
+1.400+1.60H
Length = 26.901 ft 0.279 0.055 0.60 0.900 1.00 1.00 1.00 1.00 1.00 2.38 324.90
Length = 0.09854 ft 0.003 0.055 0.60 0.900 1.00 1.00 1.00 1.00 1.00 0.02 3.22
+1.200+0.50Lr+1.60L +1.60H 0.900 1.00 1.00 1.00 1.00 1.00
Length = 26.901 ft 1 0.179 0.035 0.80 0.900 1.00 1.00 1.00 1.00 1.00 2.04 278.48
Length = 0.09854 ft 1 0.002 0.035 0.80 0.900 1.00 1.00 1.00 1.00 1.00 0.02 2.76
+1.200+1.60L +0.50S+1.60H 0.900 1.00 1.00 1.00 1.00 1.00
Length = 26.901 ft 1 0.179 0.035 0.80 0.900 1.00 1.00 1.00 1.00 1.00 2.04 278.48
Length = 0.09854 ft 1 0.002 0.035 0.80 0.900 1.00 1.00 1.00 1.00 1.00 0.02 2.76
+1.200+1.60Lr+0.50L +1.60H 0.900 1.00 1.00 1.00 1.00 1.00
Design OK
= 0.055: 1
2-2x14
= 12.84 psi
= 233.28 psi
+1.400+1.SOH
= 0.000ft
= Span# 1
Shear Values
Fb Vu rv Fv
0.00 0.00 0.00 0.00
1165.86 0.34 12.84 233.28
1165.86 0.23 12.84 233.28
0.00 0.00 0.00 0.00
1554.48 0.29 11.01 311.04
1554.48 0.19 11.01 311.04
0.00 0.00 0.00 0.00
1554.48 0.29 11.01 311.04
1554.48 0.19 11.01 311.04
0.00 0.00 0.00 0.00
M1-6
Wood Beam !ndows.-.com\FJ~Y5F-B\Aroalj1II\SEV11N1-K\FZ178C--4\lli1R2Z-N.EC6
ENERCALC, INC. 1983,2017, Buld:10.17.8.9, Ver.I~ 17.&B
I ol II I
Description : 1) 1YP Rl\J Support Beam
Load Combination Max Stress Ratios Moment Values Shear Values
Segment Length Span# M V /1, CFN Ci c, Cm C t CL Mu lb Fb Vu fv Fv
Length = 26.901 ft 1 0.179 0.035 0.80 0.900 1.00 1.00 1.00 1.00 1.00 2.04 278.48 1554.48 0.29 11.01 311.04
Length = 0.09854 ft 1 0.002 0.035 0.80 0.900 1.00 1.00 1.00 1.00 1.00 0.02 2.76 1554.46 0.19 11.01 311.04
+1.200+1.60Lr+0.50W+1.60H 0.900 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00
Length = 26.901 ft 1 0.179 0.035 0.60 0.900 1.00 1.00 1.00 1.00 1.00 2.04 278.48 1554.46 0.29 11.01 311.04
Length = 0.09854 ft 1 0.002 0.035 0.80 0.900 1.00 1.00 1.00 1.00 1.00 0.02 2.76 1554.48 0.19 11.01 311.04
+1.200+0.50L +1.60S+1.60H 0.900 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00
Length = 26.901 ft 1 0.179 0.035 0.60 0.900 1.00 1.00 1.00 1.00 1.00 2.04 276.46 1554.46 0.29 11.01 311.04
Length = 0.09854 ft 1 0.002 0.035 0.60 0.900 1.00 1.00 1.00 1.00 1.00 0.02 2.76 1554.46 0.19 11.01 311.04
+1.200+1.60S+0.50W+1.60H 0.900 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00
Length = 26.901 ft 1 0.179 0.035 0.60 0.900 1.00 1.00 1.00 1.00 1.00 2.04 278.46 1554.46 0.29 11.01 311.04
Length = 0.09654 ft 1 0.002 0.035 0.80 0.900 1.00 1.00 1.00 1.00 1.00 0.02 2.76 1554.46 0.19 11.01 311.04
+1.200+0.50Lr+0.50L +W+1.60H 0.900 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00
Length = 26.901 ft 1 0.143 0.028 1.00 0.900 1.00 1.00 1.00 1.00 1.00 2.04 278.48 1943.10 0.29 11.01 368.60
Length = 0.09854 ft 1 0.001 0.028 1.00 0.900 1.00 1.00 1.00 1.00 1.00 0.02 2.76 1943.10 0.19 11.01 368.80
+1.200+0.SOL +0.50S+W+1.60H 0.900 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00
Length = 26.901 ft 1 0.143 0.028 1.00 0.900 1.00 1.00 1.00 1.00 1.00 2.04 278.46 1943.10 0.29 11.01 368.80
Length = 0.09854 ft 1 0.001 0.028 1.00 0.900 1.00 1.00 1.00 1.00 1.00 0.02 2.76 1943.10 0.19 11.01 368.80
+ 1.200+0.50L +0.20S+E+1.60H 0.900 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00
Length = 26.901 ft 1 0.190 0.037 1.00 0.900 1.00 1.00 1.00 1.00 1.00 2.70 368.96 1943.10 0.36 14.24 388.80
Length = 0.09854 ft 1 0.002 0.037 1.00 0.900 1.00 1.00 1.00 1.00 1.00 0.02 3.22 1943.10 0.23 14.24 388.80
+1.200+0.50L +0.20S-E+1.60H 0.900 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00
Length = 26.901 ft 1 0.099 0.020 1.00 0.900 1.00 1.00 1.00 1.00 1.00 1.41 193.09 1943.10 0.21 7.76 388.80
Length = 0.09854 ft 1 0.001 0.020 1.00 0.900 1.00 1.00 1.00 1.00 1.00 0.02 2.29 1943.10 0.16 7.78 388.80
+0.90D+W+0.90H 0.900 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00
Length = 26.901 ft 0.107 0.021 1.00 0.900 1.00 1.00 1.00 1.00 1.00 1.53 208.86 1943.10 0.22 8.28 388.80
Length = 0.09854 ft 0.001 0.021 1.00 0.900 1.00 1.00 1.00 1.00 1.00 0.02 2.07 1943.10 0.15 8.26 368.80
+0.90D+E+0.90H 0.900 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00
Length = 26.901 ft 0.154 0.030 1.00 0.900 1.00 1.00 1.00 1.00 1.00 2.19 299.34 1943.10 0.30 11.49 388.80
Length = 0.09854 ft 0.001 0.030 1.00 0.900 1.00 1.00 1.00 1.00 1.00 0.02 2.53 1943.10 0.18 11.49 386.80
+0.90D-E+0.90H 0.900 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00
Length = 26.901 ft 0.065 0.013 1.00 0.900 1.00 1.00 1.00 1.00 1.00 0.92 126.01 1943.10 0.13 5.03 388.80
Length = 0.09854 ft 1 0.001 0.013 1.00 0.900 1.00 1.00 1.00 1.00 1.00 0.01 1.61 1943.10 0.11 5.03 388.80
overall Maximum Deflections
Load Combination Span Max.•-• Deft Location in Span Load Combination Max."+" Defl location in Span
+0+0.70E+H 1 0.2561 12.712 0.0000 0.000
Vertical Reactions Support notation : Far left is #1 Values in KIPS
Load Combination Support 1 Support 2
Overall MAXimum 0.567 0.195
Overall MINimum -0.206 -0.034
+O+H 0.443 0.171
+D+L+H 0.443 0.171
+D+Lr+H 0.443 0.171
+D+S+H 0.443 0.171
+0+0.750Lr+0.750L +H 0.443 0.171
+0+0.750L +O. 750S+H 0.443 0.171
+0+0.60W+H 0.443 0.171
+0+0.70E+H 0.567 0.195
+0-0.70E+H 0.300 0.147
+O+O. 750Lr+O. 750L +0.450W+H 0.443 0.171
+0+0.750L+0.750S+0.450W+H 0.443 0.171
+O+O. 750L +O. 750S+0.5250E+H 0.551 0.189
+O+O. 750L +O. 750S-0.5250E+H 0.336 0.153
+0.600+0.60W+0.60H 0.266 0.103
+0.600+0. 70E+0.60H 0.410 0.127
+0.600-0.70E+0.60H 0.122 0.079
□Only 0.443 0.171
Lr Only
LOnly
M1-7
Wood Beam
1,1111
Description : 1) TYP R1IJ Support Beam
Vertical Reactions
Load Combination
SOnly
WOnly
EOnly
E Only' -1.0
HOnly
lnclowl.-.com\FJIISyslCA2V'rqee\S6SY5F-B\Anrjlll\Se/10W-K\FZ178C-4\TH1R2Z•N.EC8
ENERCALC, INC. 1983-2017, Bulld:10.17.U Var.in 17.&9 . . .
Support notation : Far left is #1 Values in KIPS
Support 1 Support 2
0.206 0.034
-0.206 -0.034
M1-8
Steel Beam 4ndowl.--.com\FlleSyalCA2'/'roocts\S6SY5F•B\Analy1is\SEV111N-K'J'Z17&H\TH1R2Z•N.EC8
ENERCALC, INC. 1118:1-2017, Bold:10.17.8.9, Ver:1~ 17.8.9
l
t, 1111
Description : 2) 14B22-E5 to E6
CODE REFERENCES
Calculations per AISC 360-10, IBC 2012, ASCE 7-10
Load Combination Set: ASCE 7-10
Material Properties
Analysis Method: Load Resistance Factor Design
Beam Bracing : Beam is Fully Braced against latera~lof'sional buckling
Bending Axis : Major Axis Bending
0(1.134) ,(ll.1141111) ,(ll.1!48fl) ,(ll.t!Allfl) ,(ll.1!48fl) ,(ll.1'il
'i l' -
W14x22
r Span = 22.0 ft
Fy : Steel Yield :
E: Modulus:
36.0 ksi
29,000.0 ksi
. . .
Applled Loa~d,.,sc_ ___________________ s_e_rv_ic_e_lo_a_d_s_e_nt_e_re_d_. L_o_a_d_F_a_cto_rs_w_il_l b:..:e __ a"-p._p_lie_d_fo_r_ca_:,:lc_:_ul_:_at--io--n_:_s_.
Beam self weight calculated and added to loading
Loads on all spans ...
Point Load : D = 1.134, Lr= 0.6480 k, Starting at: 1.0 ft and placed every 2.0 ft thereafter
Load(s) for Span Number 1
Point Load : D = 0.4430, E = 0.2060 k @ 11.50 ft, (RTIJ BM Rxn)
Point Load: D = 0.4430, E = 0.2060 k@ 14.417 ft, (RTIJ BM Rxn)
Point Load: D = 0.4430, E = 0.2060 k@21.333 ft, (RTIJ BM Rxn)
DESIGN SUMMARY -----Maximum Bending Str&ss Ratio = 0.889 : 1
Section used for this span W14x22
Mu: Applied 79.708 k-ft
Mn• Phi : Allowable 89.640 k-ft
Load Combination +1.20D+1.60Lr+0.50L +1.60H
Maximum Shear Stress Ratio =
Section used for this span
Vu: Applied
Vn * Phi : Allowable
Load Combination
Design OK
Location of maximum on span 11.000ft
Span # where maximum occurs Span # 1
Location of maximum on span
Span # where maximum occurs
0.215 : 1
W14x22
14.619 k
68.062 k
+1.20D+1.60Lr+0.50L +1.60H
22.000 ft
Span# 1
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
0.298 in
-0.027 in
0.898 in
0.000 in
Ratio=
Ratio=
Ratio=
Ratio=
Maximum Forces & Stresses for Load Combinations
Load Combination Max Stress Ratios
Segment Length Span# M V max Mu+ max Mu -
+1.400+1.60H
Osgn. L = 22.00 ft 0.626 0.153 56.10
+1.200+0.50Lr+1.60L +1.60H
Osgn. L = 22.00 ft 0.647 0.157 57.97
+1.200+1.60L +0.50S+1.60H
Osgn. L = 22.00 ft 0.536 0.131 46.09
+1.200+1.60Lr+0.50L +1.60H
Osgn. L = 22.00 ft 0.889 0.215 79.71
+1.200+1.60Lr+0.50W+1.60H
Osgn. L = 22.00 ft 0.889 0.215 79.71
+1.200+0.50L +1.60S+1.60H
Osgn. L = 22.00 ft 0.536 0.131 48.09
+1.200+1.60S+0.50W+1.60H
Osgn. L = 22.00 ft 0.536 0.131 48.09
+1.200+0.50Lr+0.50L +W+1.80H
Osgn. L = 22.00 ft 0.647 0.157 57.97
+ 1.200+0.50L +0.50S+W+1.60H
Osgn. L = 22.00 ft 1 0.536 0.131 48.09
+1.3560+0.50L +0.20S+E+1.60H
Osgn. L = 22.00 ft 1 0.626 0.155 56.28
885>=240
9,782 >=240
294 >=180
0 <180
Summary of Moment Values
Mu Max Mnx
56.10 99.60
57.97 99.60
46.09 99.60
79.71 99.60
79.71 99.60
46.09 99.60
48.09 99.60
57.97 99.60
48.09 99.60
56.28 99.60
Phi*Mnx
89.64
89.64
89.64
89.64
69.64
89.64
89.64
69.64
89.64
89.64
Summary of Shear Values
Cb Rm VuMax Vnx Phi'Vnx
1.00 1.00 10.40 66.06 68.06
1.00 1.00 10.70 68.06 66.06
1.00 1.00 8.92 68.06 68.06
1.00 1.00 14.62 68.06 68.06
1.00 1.00 14.62 66.06 68.06
1.00 1.00 8.92 68.06 68.06
1.00 1.00 8.92 68.06 66.06
1.00 1.00 10.70 68.06 68.06
1.00 1.00 6.92 68.06 68.06
M1-9
1.00 1.00 10.52 68.06 68.06
Steel Beam
t ol 111
Description : 2) 14B22 • ES to E6
Load Combination Max Stress Ratios
Segment Length Span # M V
+1.356D+0.S0L +0.20S-E+1.60H
Dsgn. L = 22.00 ft 0.585 0.142
+0.90D+W+0.90H
Dsgn. L = 22.00 ft 0.402 0.096
+0.7436D+E+0.90H
Dsgn. L = 22.00 ft 0.354 0.066
+0.7436D-E+0.90H
Dsgn. L = 22.00 ft 1 0.311 0.075
Overall Maximum Deflections
max Mu+
52.42
36.06
31.74
27.87
j-.l>omfl>,ta,.-.'°"''flleSya\CA2'1'1'qec:11•B\AnalylllllSEV10W-K'FZ1'18C4\TH1R2Z-N.EC6
ENERCALC, INC. 11163-2017, Buld:10.17.U Ver.1~ 17.&9 . . .
Summary of Moment Values Summary of Shear Values
max Mu -Mu Max Mnx Phi*Mnx Cb Rm VuMax Vnx Phi"Vnx
52.42 99.60 89.64 1.00 1.00 9.64 68.06 68.06
36.06 99.60 89.64 1.00 1.00 6.69 68.06 68.06
31.74 99.60 89.64 1.00 1.00 5.97 68.06 68.06
27.87 99.60 89.64 1.00 1.00 5.08 68.06 68.06
----------------------------------
Load Combination
+D+Lr+H
Vertlcal Reactions
Load Combination
OVerall MAXimum
Overall MINlmum
+D+H
+D+L+H
+D+Lr+H
+D+S+H
+D+0.750Lr+0.750L +H
+D+0.750L +0.750S+H
+D+0.60W+H
+D+0.70E+H
+D-0.70E+H
+D+0. 750Lr+0. 750L +0.450W+H
+D+0.750L +0.750S+0.450W+H
+D+0.750L +0. 750S+0.5250E+H
+D+0. 750L +0. 750S-0.5250E+H
+0.60D+0.60W+0.60H
+0.60D+0.70E+0.60H
+0.60D-0.70E+0.60H
DOnly
Lr Only
L Only
SOnly
WOnly
EOnly
EOnly'-1.0
HOnly
Sp an
Support 1
10.421
-0.176
6.857
6.857
10.421
6.857
9.530
6.857
6.857
6.979
6.734
9.530
6.857
6.949
6.764
4.114
4.237
3.991
6.857
3.564
0.176
-0.176
Max.•-• Defl
0.8983
Support 2
10.994
-0.442
7.430
7.430
10.994
7.430
10.103
7.430
7.430
7.740
7.121
10.103
7.430
7.663
7.198
4.458
4.768
4.149
7.430
3.564
0.442
-0.442
location in Span Load Combination Max. •+• Deft location in Span
11.063 0.0000 0.000
Support notation : Far left is #1 Values in KIPS
M1-10
Steel Beam -.lho,1110iib1....ul.com\FlleSys\CA2'/'!qldl\S5Y6F-B\Analytls\SEV10W-K\FZ178C-.l\1H1R2Z-N.EC8
ENERCALC, INC.1983-2017, BlJld:10.17.8.9, V.-:10.17.&9
I ol II I
Description : 3) 16B28-E41o ES
CODE REFERENCES
Calculations per AISC 360-10, IBC 2012, ASCE 7-10
Load Combination Set: ASCE 7-10
Material Properties
Analysis Method : Load Resistance Factor Design
Beam Bracing : Beam is Fully Braced against lateral-torsional buckling
Banding Axis : Major Axis Bending
Fy : Steel Yield :
E: Modulus:
36.0 ksi
29,000.0 ksi
. . .
D(?A
3J)ICt:1c1..t;,t ::!.'.']t,: ,1,;tL · ... :,t:J.: ::t: ) 1 J:, ,1,;:□w,J::r:;1,:~-4)
W16x26~ W16x26 ~W16x26
rp•n = 4.01 Span = 30 .0 ft tpan = 4.01
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam se~ weight calculated and added to loading
Loads on all spans ...
Point Load : D = 1.134, Lr = 0.6480 k, Starting at : 1.0 ft and placed every 2.0 ft thereafter
Load(s) for Span Number 1
Point Load: D = 0.4430, E = 0.2060 k@2.250 ft, (RTIJ BM Rxn)
Point Load: D = 7.430, Lr= 3.564, E = 0.4424 k@ 0.0 ft, (Adjacent BM RXN)
Load(s) for Span Number 2
Point Load: D = 0.4430, E = 0.2060 k@5.167ft, (RTIJ BM Rxn)
Point Load : D = 0.4430, E = 0.2060 k @ 8.083 ft, (RTIJ BM Rxn)
Point Load : D = 0.4430, E = 0.2060 k @ 15.0 fl, (RTU BM Rxn)
Point Load: D = 0.4430, E = 0.2060 k@ 17.917ft, (RTIJ BM Rxn)
Load(s) for Span Number 3
Point Load: D = 6.237, Lr= 3.564 k@4.0 ft, (Adjacent BM RXN)
DESIGN SUMMARY Design OK
MaXlmum Bending Stress Ratio = 0.928: 1 Maximum Shear Stress Ratio = 0.246 : 1 .
Section used for this span W16x26
Mu : Applied 110. 736 k-ft
Mn • Phi : A!lowable 119.340 k-ft
Load Combinatielt20D+1.60Lr+0.50L+1.60H, LL Comb Run rL')
Location of maximum on span 15.000ft
Span # where maximum occurs Span # 2
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward To1al Deflection
0.217 in
-0.289 in
1.364 in
-0.476 in
Ratio=
Ratio=
Ratio=
Ratio=
Maximum Forces & Stresses for Load Combinations
Load Combination Max Slress Ratios
Segment Length Span# M V max Mu+ max Mu~
+1.40D+1.60H
Dsgn. L = 4.00ft 1 0.413 0.169 -49.33
Dsgn. L = 30.00 ft 2 0.510 0.168 60.85 -49.33
Dsgn. L = 4.00ft 3 0.348 0.142 -41.57
+1.20D+0.50Lr+1.60L+1.60H, LL Comb
Dsgn. L = 4.00 ft 1 0.354 0.145 -42.29
Dsgn. L = 30.00 ft 2 0.402 0.151 47.94 -44.05
Dsgn. L = 4.00ft 3 0.369 0.151 -44.05
+1.20D+0.50Lr+1.60L +1.60H, LL Comb
Dsgn. L = 4.00 ft 1 0.354 0.173 -42.29
Dsgn. L = 30.00 ft 2 0.590 0.173 70.46 -42.29
Dsgn. L = 4.00ft 3 0.299 0.122 -35.63
+1.20D+0.50Lr+1.60L +1.60H, LL Comb
Dsgn. L = 4.00ft 1 0.354 0.169 -42.29
Section used for this span W18x28
Vu : Applied 20.879 k
Vn •Phi: A!lowable 84.780 k
Load Combinatielt20D+1.60Lr+0.50L +1.60H, LL Comb Run (LL')
Location of maximum on span 4.000 ft
Span # where maximum occurs Span # 1
441 >=240
331 >=240
264 >=180
202 >=180
Summary of Moment Values Summary of Shear Values
Mu Max Mnx Phi*Mnx Cb Rm VuMax Vnx Phi'Vnx
49.33 132.60 119.34 1.00 1.00 14.34 84.78 84.78
60.85 132.60 119.34 1.00 1.00 14.24 84.78 84.78
41.57 132.60 119.34 1.00 1.00 12.05 84.78 84.78
42.29 132.60 119.34 1.00 1.00 12.29 84.78 84.78
47.94 132.60 119.34 1.00 1.00 12.76 84.78 84.78
44.05 132.60 119.34 1.00 1.00 12.76 84.78 84.78
42.29 132.60 119.34 1.00 1.00 14.63 84.78 84.78
70.46 132.60 119.34 1.00 1.00 14.63 84.78 84.78
35.63 132.60 119.34 1.00 1.00 10.33 ~?~1 84.78
42.29 132.60 119.34 1.00 1.00 14.35 84.78 84.78
Steel Beam i ___ camlflloSys\CA2\PlojeCII\SY5F•BIAllalyals\SEV1ow-KV'Z1-\TH1R2Z•N.EC8
ENERCAI.C, INC. 1983-2017, Bl.«d:10.17.&9, V.:10.17.8.9
1,1111 .
Description : 3) 16826 -E4 to E5
Load Combination Max Slress Ratios Summary of Moment Values Summary of Shear Values
Segment Leng1h Span# M V max Mu+ max.Mu~ Mu Max Mnx Phi'Mnx Cb Rm VuMax Vnx Phi1Vnx
Dsgn. L • 30.00 ft 2 0.555 0.169 66.25 -44.05 66.25 132.60 119.34 1.00 1.00 14.35 84.78 84.78
Dsgn. L • 4.00ft 3 0.369 0.151 -44.05 44.05 132.60 119.34 1.00 1.00 12.76 84.78 84.78
+1.200+0.50Lr+1.60L +1.60H, LL Comb
Osgn. L • 4.00ft 1 0.425 0.174 -50.71 50.71 132.60 119.34 1.00 1.00 14.72 84.78 84.78
Osgn. L • 30.00 ft 2 0.425 0.147 47.94 -50.71 50.71 132.60 119.34 1.00 1.00 12.49 84.78 84.78
Osgn. L • 4.00ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 84.78 84.78
+1.200+0.50Lr+1.60L +1.60H, LL Comb
Dsgn. L • 4.00ft 1 0.425 0.174 -50.71 50.71 132.60 119.34 1.00 1.00 14.72 84.78 84.78
Osgn. L • 30.00 ft 2 0.425 0.151 43.73 -50.71 50.71 132.60 119.34 1.00 1.00 12.76 84.78 84.78
Osgn. L • 4.00ft 3 0.369 0.151 -44.05 44.05 132.60 119.34 1.00 1.00 12.76 84.76 84.78
+1.200+0.50Lr+1.60L+1.60H, LL Comb
Osgn. L • 4.00ft 1 0.425 0.176 -50.71 50.71 132.60 119.34 1.00 1.00 14.92 84.78 84.78
Osgn. L • 30.00 ft 2 0.555 0.176 66.25 -50.71 66.25 132.60 119.34 1.00 1.00 14.92 84.78 84.78
Osgn. L • 4.00ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 84.78 84.78
+1.200+0.50Lr+1.60L +1.60H, LL Comb
Osgn. L • 4.00ft 1 0.425 0.174 -50.71 50.71 132.60 119.34 1.00 1.00 14.72 84.78 84.78
Dsgn. L • 30.00 ft 2 0.520 0.173 62.04 -50.71 62.04 132.60 119.34 1.00 1.00 14.63 84.78 84.78
Osgn. L • 4.00ft 3 0.369 0.151 -44.05 44.05 132.60 119.34 1.00 1.00 12.76 84.78 84.78
+1.200+1.60L +0.50S+1.60H, LL Comb F
Dsgn. L • 4.00ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 84.78 84.78
Osgn. L • 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 84.78 84.78
Dsgn. L • 4.00ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 84.78 84.78
+1.200+1.60L +0.50S+1.60H, LL Comb F
Dsgn. L • 4.00ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 84.78 84.78
Osgn. L • 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 84.78 84.78
Dsgn. L • 4.00ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 84.78 84.78
+1.200+1.60L +0.50S+1.60H, LL Comb F
Dsgn. L • 4.00ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 84.78 84.78
Dsgn. L • 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 84.78 84.78
Dsgn. L • 4.00ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 84.78 84.78
+1.200+1.60L +0.50S+1.60H, LL Comb F
Osgn. L • 4.00ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 84.78 84.78
Osgn. L • 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 84.78 84.78
Osgn. L • 4.00ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 84.78 84.78
+1.200+1.60L +0.50S+1.60H, LL Comb F
Dsgn. L • 4.00ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 84.78 84.78
Osgn. L • 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 84.78 84.78
Osgn. L • 4.00ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 84.78 84.78
+1.200+1.60L +0.50S+1.60H, LL Comb F
Osgn. L • 4.00ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 84.78 84.78
Osgn. L • 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 84.78 84.78
Osgn. L • 4.00ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 84.78 84.78
+1.200+1.60L +0.50S+1.60H, LL Comb F
Osgn. L • 4.00ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 84.78 84.78
Osgn. L • 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 84.78 84.78
Osgn. L • 4.00ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 84.78 84.78
+1.200+1.60Lr+0.50L +1.60H, LL Comb
Osgn. L • 4.00ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 84.78 84.78
Dsgn. L • 30.00 ft 2 0.524 0.214 38.68 -62.59 62.59 132.60 119.34 1.00 1.00 18.11 84.78 84.78
Osgn. L • 4.00ft 3 0.524 0.214 -62.59 62.59 132.60 119.34 1.00 1.00 18.11 84.78 84.78
+1.200+1.60Lr+0.50L +1.60H, LL Comb
Osgn. L • 4.00 ft 1 0.354 0.236 -42.29 42.29 132.60 119.34 1.00 1.00 19.98 84.78 84.78
Dsgn. L • 30.00 ft 2 0.928 0.236 110.74 -42.29 110.74 132.60 119.34 1.00 1.00 19.98 84.78 84.78
Osgn. L • 4.00 ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 84.78 84.78
+1.200+1.60Lr+0.50L +1.60H, LL Comb
Osgn. L • 4.00ft 1 0.354 0.225 -42.29 42.29 132.60 119.34 1.00 1.00 19.08 84.78 84.78
Dsgn. L • 30.00 ft 2 0.815 0.235 97.26 -62.59 97.26 132.60 119.34 1.00 1.00 19.94 84.78 84.78
Dsgn. L • 4.00ft 3 0.524 0.214 -62.59 62.59 132.60 119.34 1.00 1.00 18.11 84.78 84.78
+1.20D+1.60Lr+0.50L+1.60H, LL Comb
Dsgn. L• 4.00ft 1 0.580 0.237 -69.24 69.24 132.60 119.34 1.00 1.00 20.07 84.78 84.78
Dsgn. L • 30.00 ft 2 0.580 0.155 38.92 -69.24 69.24 132.60 119.34 1.00 1.00 13.10 84.78 84.78
Dsgn. L • 4.00 ft 3 0.299 0.122 -35.63 35.83 132.60 119.34 1.00 1.00 10.33 84.78 84.78
+1.200+1.60Lr+0.50L +1.60H, LL Comb
Osgn. L • 4.00ft 1 0.580 0.237 -69.24 69.24 132.60 119.34 1.00 1.00 20.07 84.78 84.78
Osgn. L • 30.00 ft 2 0.580 0.214 25.20 -69.24 69.24 132.60 119.34 1.00 1.00 18.11 84.78 84.78
Osgn. L • 4.00 ft 3 0.524 0.214 -62.59 62.59 132.60 119.34 1.00 1.00 18.11 84.78 84.78
+1.200+1.60Lr+0.50L +1.60H, LL Comb
Dsgn. L • 4.00ft 1 0.580 0.246 -69.24 69.24 132.60 119.34 1.00 1.00 20.88 111111•2 84.78
Osgn. L • 30.00 ft 2 0.815 0.246 97.26 -69.24 97.26 132.60 119.34 1.00 1.00 20.88 84.78 84.78
Steel Beam jndow9.-.com\FlloSyslCA2'l'rojocla\Yilf•BIAnalyei.-,ev1ow-K1FZ178C-4\Tlt1R2Z•N.EC8
ENERCALC, INC 1983-2017, Buid:10.17.8.9, Vtr:10.17.&9
I ol 111 .
Description: 3) 16B26-E4 to E5
Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values
Segmen1 Length Span# M V max Mu+ max Mu-Mu Max Mnx Phi*Mnx Cb Rm VuMax Vnx Phi'Vnx
Dsgn. L = 4.00 ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 64.78 64.78
+1.20D+1.60Lr+0.50L +1.60H, LL Comb
Dsgn. L = 4.00 ft 1 0.580 0.237 -69.24 69.24 132.60 119.34 1.00 1.00 20.07 64.78 64.78
Dsgn. L = 30.00 ft 2 0.702 0.236 83.78 -69.24 83.78 132.60 119.34 1.00 1.00 19.98 64.78 64.78
Dsgn. L = 4.00ft 3 0.524 0.214 -62.59 62.59 132.60 119.34 1.00 1.00 18.11 64.78 64.78
+1.20D+1.60Lr+0.50W+1.60H, LL Comb
Dsgn. L = 4.00ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 64.78 64.78
Dsgn. L = 30.00 ft 2 0.524 0.214 38.68 -62.59 62.59 132.60 119.34 1.00 1.00 18.11 64.78 64.78
Dsgn. L = 4.00ft 3 0.524 0.214 -62.59 62.59 132.60 119.34 1.00 1.00 18.11 64.78 64.78
+1.20D+1.60Lr+0.50W+1.60H, LL Comb
Dsgn. L = 4.00ft 1 0.354 0.236 -42.29 42.29 132.60 119.34 1.00 1.00 19.98 64.78 64.78
Dsgn. L = 30.00 ft 2 0.928 0.236 110.74 -42.29 110.74 132.60 119.34 1.00 1.00 19.98 64.78 64.78
Dsgn. L = 4.00ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 64.78 64.78
+1.20D+1.60Lr+0.50W+1.60H, LL Comb
Dsgn. L = 4.00 ft 1 0.354 0.225 -42.29 42.29 132.60 119.34 1.00 1.00 19.08 64.78 64.78
Dsgn. L = 30.00 ft 2 0.815 0.235 97.26 -62.59 97.26 132.60 119.34 1.00 1.00 19.94 64.78 64.78
Dsgn. L = 4.00 ft 3 0.524 0.214 -62.59 62.59 132.60 119.34 1.00 1.00 18.11 64.78 64.78
+1.20D+1.60Lr+0.50W+1.60H, LL Comb
Dsgn. L = 4.00 ft 1 0.580 0.237 -69.24 69.24 132.60 119.34 1.00 1.00 20.07 64.78 64.78
Dsgn. L = 30.00 ft 2 0.580 0.155 38.92 -69.24 69.24 132.60 119.34 1.00 1.00 13.10 64.78 64.78
Dsgn. L = 4.00 ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 64.78 64.78
+1.20D+1.60Lr+0.50W+1.60H, LL Comb
Dsgn. L = 4.00 ft 1 0.580 0.237 -69.24 69.24 132.60 119.34 1.00 1.00 20.07 64.78 84.78
Dsgn. L = 30.00 ft 2 0.580 0.214 25.20 -69.24 69.24 132.60 119.34 1.00 1.00 18.11 64.78 64.78
Dsgn. L = 4.00 ft 3 0.524 0.214 -62.59 62.59 132.60 119.34 1.00 1.00 18.11 64.78 64.78
+1.20D+1.60Lr+0.50W+1.60H, LL Comb
Dsgn. L = 4.00 ft 1 0.580 0.246 -69.24 69.24 132.60 119.34 1.00 1.00 20.88 64.78 64.78
Dsgn. L = 30.00 ft 2 0.815 0.246 97.26 -69.24 97.26 132.60 119.34 1.00 1.00 20.88 64.78 64.78
Dsgn. L = 4.00 ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 64.78 64.78
+1.20D+1.60Lr+0.50W+1.60H, LL Comb
Dsgn. L = 4.00 ft 1 0.580 0.237 -69.24 69.24 132.60 119.34 1.00 1.00 20.07 64.78 64.78
Dsgn. L = 30.00 ft 2 0.702 0.236 83.78 -69.24 83.78 132.60 119.34 1.00 1.00 19.98 64.78 64.78
Dsgn. L = 4.00ft 3 0.524 0.214 -62.59 62.59 132.60 119.34 1.00 1.00 18.11 64.78 64.78
+1.20D+0.50L +1.60S+1.60H, LL Comb F
Dsgn. L = 4.00ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 64.78 64.78
Dsgn. L = 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 64.78 64.78
Dsgn. L = 4.00ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 64.78 64.78
+1.20D+0.50L +1.60S+1.60H, LL Comb F
Dsgn. L = 4.00ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 64.78 64.78
Dsgn. L = 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 64.78 64.78
Dsgn. L = 4.00ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 64.78 64.78
+1.20D+0.50L +1.60S+1.60H, LL Comb F
Dsgn. L = 4.00 ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 64.78 64.78
Dsgn. L = 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 64.78 64.78
Dsgn. L = 4.00 ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 64.78 84.78
+1.20D+0.50L +1.60S+1.60H, LL Comb F
Dsgn. L = 4.00 ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 64.78 64.78
Dsgn. L = 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 84.78 84.78
Dsgn. L = 4.00 ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 64.78 64.78
+1.20D+0.50L +1.60S+1.60H, LL Comb F
Dsgn. L = 4.00 ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 64.78 64.78
Dsgn. L = 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 64.78 64.78
Dsgn. L = 4.00 ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 64.78 64.78
+1.20D+0.50L +1.60S+1.60H, LL Comb F
Dsgn. L = 4.00 ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 64.78 64.78
Dsgn. L = 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 64.78 64.78
Dsgn. L = 4.00 ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 64.78 64.78
+1.20D+0.50L +1.60S+1.60H, LL Comb f
Dsgn. L = 4.00 ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 64.78 64.78
Dsgn. L = 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 64.78 64.78
Dsgn. L = 4.00 ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 64.78 64.78
+1.20D+1.60S+0.50W+1.60H
Dsgn. L = 4.00 ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 64.78 64.78
Dsgn. L = 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 64.78 64.78
Dsgn. L = 4.00 ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 64.78 64.78
+1.20D+0.50Lr+0.50L+W+1.60H, LL Cor
Dsgn. L = 4.00 ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 64.78 64.78
Dsgn. L = 30.00 ft 2 0.402 0.151 47.94 -44.05 47.94 132.60 119.34 1.00 1.00 12.76 111A1&3 64.78
Dsgn. L = 4.00 ft 3 0.369 0.151 -44.05 44.05 132.60 119.34 1.00 1.00 12.76 64.78 64.78
Steel Beam Oldows.lhornlonlomaleU.camlfl~-BIAl18fy1is\SEV111N-K\FZ118C-4\TH1R2Z•N.EC8
ENERCALC, INC. 11183-2011, Bulld:10.11.8.~ Vor.m 17.8.9
I ol II I •
Description : 3) 16826 -E4 to E5
Load Combination Max S~ess Ratios Summary of Moment Values Summary of Shear Values
Segment Length Span# M V max Mu+ max.Mu-Mu Max Mnx Phi*Mnx Cb Rm VuMax Vnx Phi'Vnx
+1.20D+0.50Lr-t0.50L +W+1.60H, LL Cor
Dsgn. L = 4.00ft 1 0.354 0.173 -42.29 42.29 132.60 119.34 1.00 1.00 14.63 84.78 84.78
Dsgn. L = 30.00 ft 2 0.590 0.173 70.46 -42.29 70.46 132.60 119.34 1.00 1.00 14.63 84.78 84.78
Dsgn. L = 4.00ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 84.78 84.78
+1.20D+0.50Lr-t0.50L +W+1.60H, LL Cor
Dsgn. L = 4.00ft 1 0.354 0.169 -42.29 42.29 132.60 119.34 1.00 1.00 14.35 84.78 84.78
Dsgn. L = 30.00 ft 2 0.555 0.169 66.25 -44.05 66.25 132.60 119.34 1.00 1.00 14.35 84.78 84.78
Dsgn. L = 4.00ft 3 0.369 0.151 -44.05 44.05 132.60 119.34 1.00 1.00 12.76 84.78 84.78
+1.20D+0.50Lr-t0.50L+W+1.60H, LL Cor
Dsgn. L = 4.00ft 1 0.425 0.174 -50.71 50.71 132.60 119.34 1.00 1.00 14.72 84.78 84.78
Dsgn. L = 30.00 ft 2 0.425 0.147 47.94 -50.71 50.71 132.60 119.34 1.00 1.00 12.49 84.78 84.78
Dsgn. L = 4.00ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 84.78 84.78
+1.20D+0.50Lr-t0.50L +W+1.60H, LL Cor
Dsgn. L = 4.00ft 1 0.425 0.174 -50.71 50.71 132.60 119.34 1.00 1.00 14.72 84.78 84.78
Dsgn. L = 30.00 ft 2 0.425 0.151 43.73 -50.71 50.71 132.60 119.34 1.00 1.00 12.76 84.78 84.78
Dsgn. L = 4.00ft 3 0.369 0.151 -44.05 44.05 132.60 119.34 1.00 1.00 12.76 84.78 84.78
+1.20D+0.50Lr-t0.50L +W+1.60H, LL Cor
Dsgn. L = 4.00ft 1 0.425 0.176 -50.71 50.71 132.60 119.34 1.00 1.00 14.92 84.78 84.78
Dsgn. L = 30.00 ft 2 0.555 0.176 66.25 -50.71 66.25 132.60 119.34 1.00 1.00 14.92 84.78 84.78
Dsgn. L = 4.00ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 84.78 84.78
+1.20D+0.50Lr-t0.50L +W+1.60H, LL Cor
Dsgn. L = 4.00ft 1 0.425 0.174 -50.71 50.71 132.60 119.34 1.00 1.00 14.72 84.78 84.78
Dsgn. L = 30.00 ft 2 0.520 0.173 62.04 -50.71 62.04 132.60 119.34 1.00 1.00 14.63 84.78 84.78
Dsgn. L = 4.00ft 3 0.369 0.151 -44.05 44.05 132.60 119.34 1.00 1.00 12.76 84.78 84.78
+1.20D+0.50L +0.50S+W+1.60H, LL Coo
Dsgn. L = 4.00ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 84.78 84.78
Dsgn. L = 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 84.78 84.78
Dsgn. L = 4.00ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 84.78 84.78
+1.20D+0.50L +0.50S+W+1.60H, LL Coo
Dsgn. L = 4.00ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 84.78 84.78
Dsgn. L = 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 84.78 84.78
Dsgn. L = 4.00ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 84.78 84.78
+1.20D+0.50L +0.50S+W+1.60H, LL Coo
Dsgn. L = 4.00ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 84.78 84.78
Dsgn. L = 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 84.78 84.78
Dsgn. L = 4.00ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 84.78 84.78
+1.20D+0.50L +0.50S+W+1.60H, LL Coo
Dsgn. L = 4.00ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 84.78 84.78
Dsgn. L = 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 84.78 84.78
Dsgn. L = 4.00ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 84.78 84.78
+1.20D+0.50L +0.50S+W+1.60H, LL Coo
Dsgn. L = 4.00ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 84.78 84.78
Dsgn. L = 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 84.78 84.78
Dsgn. L = 4.00ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 84.78 84.78
+1.20D+0.50L+0.50S+W+1.60H, LL Con
Dsgn. L = 4.00ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 84.78 84.78
Dsgn. L = 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 84.78 84.78
Dsgn. L = 4.00ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 84.78 84.78
+1.20D+0.50L +0.50S+W+1.60H, LL Coo
Dsgn. L = 4.00ft 1 0.354 0.145 -42.29 42.29 132.60 119.34 1.00 1.00 12.29 84.78 84.78
Dsgn. L = 30.00 ft 2 0.437 0.144 52.16 -42.29 52.16 132.60 119.34 1.00 1.00 12.20 84.78 84.78
Dsgn. L = 4.00 ft 3 0.299 0.122 -35.63 35.63 132.60 119.34 1.00 1.00 10.33 84.78 84.78
+1.356D+0.50L +0.20S+E+1.60H, LL Cor
Dsgn. L = 4.00ft 1 0.418 0.172 -49.93 49.93 132.60 119.34 1.00 1.00 14.54 84.78 84.78
Dsgn. L = 30.00 ft 2 0.520 0.170 62.04 -49.93 62.04 132.60 119.34 1.00 1.00 14.37 84.78 84.78
Dsgn. L = 4.00ft 3 0.337 0.138 -40.27 40.27 132.60 119.34 1.00 1.00 11.68 84.78 84.78
+1.356D+0.50L +0.20S+E+1.60H, LL Cor
Dsgn. L = 4.00ft 1 0.418 0.172 -49.93 49.93 132.60 119.34 1.00 1.00 14.54 84.78 84.78
Dsgn. L = 30.00 ft 2 0.520 0.170 62.04 -49.93 62.04 132.60 119.34 1.00 1.00 14.37 84.78 84.78
Dsgn. L = 4.00ft 3 0.337 0.138 -40.27 40.27 132.60 119.34 1.00 1.00 11.68 84.78 84.78
+1.356D+0.50L +0.20S+E+1.60H, LL Cor
Dsgn. L = 4.00ft 1 0.418 0.172 -49.93 49.93 132.60 119.34 1.00 1.00 14.54 84.78 84.78
Dsgn. L = 30.00 fl 2 0.520 0.170 62.04 -49.93 62.04 132.60 119.34 1.00 1.00 14.37 84.78 84.78
Dsgn. L = 4.00 ft 3 0.337 0.138 -40.27 40.27 132.60 119.34 1.00 1.00 11.68 84.78 84.78
+1.356D+0.50L +0.20S+E+1.60H, LL Cor
Dsgn. L = 4.00fl 1 0.418 0.172 -49.93 49.93 132.60 119.34 1.00 1.00 14.54 84.78 84.78
Dsgn. L = 30.00 fl 2 0.520 0.170 62.04 -49.93 62.04 132.60 119.34 1.00 1.00 14.37 84.78 84.78
Dsgn. L = 4.00fl 3 0.337 0.138 -40.27 40.27 132.60 119.34 1.00 1.00 11.68 lllll11t4 84.78
+1.356D+0.50L +0.20S+E+1.60H, LL Cor
Steel Beam
I, II ti
Description : 3) 16B26 -E4 to E5
Load Combination Max Stress Ratios
indowl.-.o,mlflleSya\CA2'11'1qeYilF•!Mnayoa\SEV10W-KIFZ178C-4\TH1R2Z•N.EC8
ENERC.11.C, INC. 1983-2017, Buld:10.17.8.9, Ver:10.17.8.9
•
Summary of Moment Values Summary of Shear Values
Segment Length Span# M V max Mu+ max Mu-Mu Max Mnx Phi*Mnx Cb Rm VuMax Vnx Phl'Vnx
Osgn. L = 4.00ft 1 0.418
Osgn. L = 30.00 ft 2 0.520
Osgn. L = 4.00ft 3 0.337
+1.356O+0.50L +0.20S+E+1.60H, LL Cor
Osgn. L = 4.00ft 1 0.418
Osgn. L = 30.00 ft 2 0.520
Osgn. L = 4.00ft 3 0.337
+1.356D+0.50L +0.20S+E+1.60H, LL Cor
Dsgn. L= 4.00ft 1 0.418
Dsgn. L = 30.00 ft 2 0.520
Osgn. L = 4.00 ft 3 0.337
+0.90D+W+0.90H
Osgn. L = 4.00 ft 1 0.266
Dsgn. L = 30.00 ft 2 0.328
Osgn. L = 4.00 ft 3 0.224
+0.7436D+E+0.90H
Dsgn. L = 4.00 ft 1 0.237
Dsgn. L = 30.00 ft 2 0.297
Dsgn. L = 4.00 ft 3 0.185
Overall Maximum Deflections --~-·-· ----------
load Combination Span
+O+Lr+H
Vertical Reactions
1
2
3
Load Combination Support 1
Overall MAJ<imum
Overall MINimum
+D+H
+D+L +H, LL Comb Run (tiL)
+D+L +H, LL Comb Run ('l')
+D+L +H, LL Comb Run rLL)
+D+L+H, LL Comb Run (L ti)
+D+L+H, LL Comb Run (l'L)
+D+L +H, LL Comb Run (LL')
+D+L +H, LL Comb Run (LLL)
+D+LrtH, LL Comb Run (''L)
+O+LrtH, LL Comb Run ('L ')
+O+LrtH, LL Comb Run ('LL)
+O+LrtH, LL Comb Run (L '1
+D+Lr+H, LL Comb Run (L *L)
+D+LrtH, LL Comb Run (LL')
+D+LrtH, LL Comb Run (LLL)
+D+S+H
+D+0.750Lrt0.750L+H, LL Comb Run('
+D+0.750Lrt0.750L+H, LL Comb Run('
+D+0.750Lrt0.750L+H, LL Comb Run('
+D+0.750Lrt0.750L+H, LL Comb Run (L
+D+0.750Lrt0.750L+H, LL Comb Run (L
+D+0.750Lrt0.750L+H, LL Comb Run (L
+D+0.750Lrt0.750L+H, LL Comb Run (L
+D+0.750L+0.750S+H, LL Comb Run (ti
+D+0.750L+0.750S+H, LL Comb Run ('l
+D+0.750L+0.750S+H, LL Comb Run ('l
+O+0.750L+0.750S+H, LL Comb Run (L'
+O+0.750L+0.750S+H, LL Comb Run (L'
+O+0.750L+0.750S+H, LL Comb Run (LI
+O+0.750L+0.750S+H, LL Comb Run (LI
+D+0.60W+H
+D+0.70E+H
+D+0.750Lrt0.750L+0.450W+H, LL Co•
+D+0.750Lrt0.750L+0.450W+H, LL Co•
+D+0.750Lr+0.750L+0.450W+H, LL Co•
+D+0.750Lr+0.750L+0.450W+H, LL Co•
0.172
0.170
0.138
0.172
0.170
0.138
0.172
0.170
0.138
0.109
0.108
0.091
0,098
0.096
0.076
Max. ft_. Defl
0.0000
1.3637
0.0000
Support 2
30.697
-0.562
20.415
20.415
20.415
20.415
20.415
20.415
20.415
20.415
19.854
25.275
24.714
25.837
25.275
30.697
30.135
20.415
19.994
24.060
23.639
24.481
24.080
28.126
27.705
20.415
20.415
20.415
20.415
20.415
20.415
20.415
20.415
21.274
19.994
24.060
23.639
24.481
-49.93
62.04 -49.93
-40.27
-49.93
62.04 -49.93
-40.27
-49.93
62.04 -49.93
-40.27
-31.72
39.12 -31.72
-26.72
-28.33
35.41 -28.33
-22.08
Location in Span
0.000
15.200
15.200
49.93 132.60
62.04 132.60
40.27 132.60
49.93 132.60
62.04 132.60
40.27 132.60
49.93 132.60
62.04 132.60
40.27 132.60
31.72 132.60
39.12 132.60
26.72 132.60
28.33 132.60
35.41 132.60
22.08 132.60
Load Combination
+D+Lr+H
+D+Lr+H
Support notation : Far left is #1
Support 3
28.282
0.246
18.001
18.001
18.001
18.001
18.001
18.001
18.001
18.001
23.422
22.861
28.282
17.439
22.861
22.299
27.721
18.001
22.067
21.646
25.712
17.580
21.646
21.225
25.291
18.001
18.001
18.001
18.001
18.001
18.001
18.001
18.001
18.173
22.067
21.848
25.712
17.580
Support4
119.34
119.34
119.34
119.34
119.34
119.34
119.34
119.34
119.34
119.34
119.34
119.34
119.34
119.34
119.34
1.00 1.00 14.54
1.00 1.00 14.37
1.00 1.00 11.68
1.00 1.00 14.54
1.00 1.00 14.37
1.00 1.00 11.68
1.00 1.00 14.54
1.00 1.00 14.37
1.00 1.00 11.68
1.00 1.00 9.22
1.00 1.00 9.15
1.00 1.00 7.75
1.00 1.00 8.27
1.00 1.00 8.14
1.00 1.00 6.40
Max. •+• Defl
-0.4556
0.0000
-0.4761
Values in KIPS
84.78 84.78
84.78 84.78
84.78 84.78
84.78 84.78
84.78 84.78
84.78 84.78
84.78 84.78
84.78 84.78
84.78 84.78
84.78 84.78
84.78 84.78
84.78 84.78
84.78 84.78
84.78 84.78
84.78 84.78
Location in Span
0.000
0.000
4.000
M1-15
Steel Beam
1,1111
Description : 3) 16B28-E4 to E5
Vertical Reactions
Load Combination Support 1
+D+0.750Lr+0.750L+0.450W+H, LL Con
+D+0.750Lr+0.750L+0.450W+H, LL Con
+D+0.750Lr+0.750L+0.450W+H, LL Con
+D+0.750L +0. 750S+0.450W+H, LL Com
+D+0.750L +0. 750S+0.450W+H, LL Com
+D+0.750L+0.750S+0.450W+H, LL Com
+D+0.750L+0.750S+0.450W+H, LL Com
+D+0.750L+0.750S+0.450W+H, LL Com
+D+0.750L+0.750S+0.450W+H, LL Com
+D+0.750L+0.750S+0.450W+H, LL Com
+D+0.750L+0.750S+0.5250E+H, LL Con
+D+0.750L+0.750S+0.5250E+H, LL Con
+D+0.750L+0.750S+0.5250E+H, LL Con
+D+0.750L+0.750S+0.5250E+H, LL Con
+D+0.750L+0.750S+0.5250E+H, LL Con
+D+0.750L+0.750S+0.5250E+H, LL Con
+D+0.750L+0.750S+0.5250E+H, LL Con
+0.60D+0.60W+0.60H
+0.60D+0. 70E+0.60H
DOnly
Lr Only, LL Comb Run ("L)
Lr Only, LL Comb Run ('L ')
Lr Only, LL Comb Run ('LL)
Lr Only, LL Comb Run (L ")
Lr Only, LL Comb Run (L 'L)
Lr Only, LL Comb Run (LL')
Lr Only, LL Comb Run (LLL)
L Only, LL Comb Run ("L)
L Only, LL Comb Run ('L 1
L Only, LL Comb Run ('LL)
L Only, LL Comb Run (L'1
L Only, LL Comb Run (L'L)
L Only, LL Comb Run (LL')
L Only, LL Comb Run (LLL)
sonly
WOnly
EOnly
HOnly
Support 2
24.060
28.126
27.705
20.415
20.415
20.415
20.415
20.415
20.415
20.415
21.059
21.059
21.059
21.059
21.059
21.059
21.059
12.249
13.108
20.415
-0.562
4.860
4.298
5.422
4.860
10.282
9.720
1.226
!ndowl.-.com\FileSyslCA2'f'nljedl\SY5F•B\Analy1II\SEV1IJW-KIJ'Z1~\TH1R2Z•N.EC8
ENERCALC, INC.1983-2017, Buld:10.17.8.9, Ver:1~ 17.&9
Support notation : Far left is #1
Support 3 Support 4
21.846
21.225
25.291
18.001
18.001
18.001
18.001
18.001
18.001
18.001
18.130
18.130
18.130
18.130
18.130
18.130
18.130
10.800
10.973
18.001
5.422
4.860
10.282
-0.562
4.860
4.298
9.720
0.246
. . .
Values in KIPS
M1-16
Steel Column -.111om1o1-.com1AleSys\CA2'l'lqeY5HMnaiy11s\SEV1ow-K\FZ1-ITH1R2Z•N.EC8
ENERCALC, INC. 1883-2017, Bi.td:10.17.8.11, Ver.10.17.&9
I ,I II I
Description : 4) E~sling S188I Column
Code Refelances -------
Calculations per AISC 360-10, IBC 2012, CBC 2013, ASCE 7-10
Load Combinations Used : ASCE 7-10
General Information
Steel Section Name : Plpa4STD
. . .
Overall Column Height 15.40 ft
Analysis Method: Load Resistance Factor Top & Bottom Fixity Top & Bottom Pinned
Steel Stress Grade
Fy: Steel Yield 33.0 ksi
E: Elastic Bending Modulus 29,000.0 ksi
Brace condition for deflection (buckling) along columns :
X-X (width) a,os :
Unbraced Length forX-XAxis buckling• 15.40 ft, K • 1.0
Y-Y (depth) axis:
Unbrace<iLeng1h forY-Y Axis budding, 15.40 ft, K • 1.0
Applled Loeds Service loads entered. Load Factors will be applied for calculations.
Column self weight Included: 166.320 lbs• Dead Load Factor
AXIAL LOADS ...
BM RXN: AJOal Load at 15.40 ft, D = 20.415, LR= 10.282, E = 1.226 k
DESIGN SUMMARY
Banding & Shear Check Results
PASS Max. AJOal+Bending Stress Ratio , 0.9643 : 1
Load Combination +1.20D+1.60Lr+0.50L +1.60H
Location of max.above base 0.0 ft
At maximum location values are ...
Pu
0.9" Pn
Mu-x
0.9 'Mn-x:
Mu-y
0.9 'Mn-y:
PASS Ma,omum Shear Stress Ratio=
Load Combination
LocaUon of max.above base
At maximum location values are ...
Vu: Applied Vn • Phi : Allowable
Load Combination Results
Load Combination
+1.40D+1.60H
+1.20D+0.50Lr+1.60L +1.60H
+1.20D+1.60L+0.50S+1.60H
+1.20D+1.60Lr+0.50L +1.60H
+1.20D+1.60Lr+0.50W+1.60H
+1.20D+0.50l +1.60S+1.60H
+1.20D+1.60S+0.50W+1.60H
+1.20D+0.50Lr+0.50l +W+1.60H
+1.20D+0.50L +0.50S+W+1.60H
+1.356D+0.50L +0.20S+E+1.60H
+1.356D+0.50L +0.20S-E+1.60H
+0.900+W+0.90H
+0.7436D+E+0.90H
+0.74360-E+O.OOH
41.149 k
42.672 k
0.0 k-ft
10.024 k-ft
0.0 k-ft
10.024 k-ft
0.0 : 1
0.0 ft
0.0 k
0.0 k
Maximum Axial + Bending Stress Ratios
Stress Ratio Status Location
0.675 PASS 0.00 ft
0.699 PASS 0.00 ft
0.579 PASS 0.00 ft
0.964 PASS 0.00 ft
0.964 PASS 0.00 ft
0.579 PASS 0.00 ft
0.579 PASS 0.00 ft
0.699 PASS 0.00 ft
0.579 PASS 0.00 ft
0.683 PASS 0.00 ft
0.625 PASS 0.00 ft
0.434 PASS 0.00 ft
0.387 PASS 0.00 ft
0.330 PASS 0.00 ft
Maximum Load Reactions ..
Top along X-X
Bottom along X-X
TopalongY-Y
Bottom along Y-Y
Maximum Load Deflections ...
0.0 k
0.0 k
0.0 k
0.0 k
Along Y-Y 0.0 in a1 0.0ft above base
for load combination :
Along X-X 0.0 in at 0.0ft above base
for load combination :
Maximum Shear Ratios
Stress Ratio Status Location
0.000 PASS 0.00 ft
0.000 PASS 0.00 ft
0.000 PASS 0.00 ft
0.000 PASS 0.00 ft
0.000 PASS 0.00 ft
0.000 PASS 0.00 ft
0.000 PASS 0.00 ft
0.000 PASS 0.00 ft
0.000 PASS 0.00 ft
0.000 PASS 0.00 ft
0.000 PASS 0.00 ft
0.000 PASS 0.00 ft
0.000 PASS 0.00 ft
0.000 PASS 0.00 ft
M1-17
.. ,.
'
Steel Column
I ol II I
Description : 4) EJdsting S1eel Column
Maximum Reactions
Load Combination
+D+H
+D+L+H
+D+Lr+H
+D+S+H
+D+0.750Lr<-0.750L +H
+D+0.750L +0.750S+H
+D+0.60W+H
+D+0.70E+H
+D-0.70E+H
Axial Reaction
@Base
+D+0. 750Lr>0. 750L +0.450W+H
+D+0.750L +0. 750S+0.450W+H
+D+0.750L +0. 750S+0.5250E+H
+D+0. 750L +O. 750S-0.5250E +H
+0.60D+0.60W+0.60H
+0.60D+0. 70E+0.60H
+0.60D-0.70E+0.60H
20.581
20.581
30.863
20.581
28.293
20.581
20.581
21.440
19.723
28.293
20.581
21.225
19.938
12.349
13.207
11.491
20.581
10.282
DOnly
Lr Only
LOnly
SOnly
WOnly
EOnly
EOnly'-1.0
HOnly
Extrema Reactions
Item
Axlal@Base
Reaction, X-X Axis Base
Reaction, Y-Y Axis Base
Reaction, X-X Axis Top
Reaction, Y-Y Axis Top
Moment, X-X Axis Base
Momen~ Y-Y Axis Base
Moment, X-XAxls Top
Moment, Y-Y Axis Top
1.226
-1.226
-----~. Axial Reaction
Extreme Value @Base
Maximum 30.863
Minimum -1.226
Maximum 20.581
Minimum 20.581
Maximum 20.581
Minimum 20.581
Maximum 20.581
Minimum 20.581
Ma~mum 20.581
Minimum 20.581
Maximum 20.581
Minimum 20.581
Maximum 20.581
Minimum 20.581
Maximum 20.581
Minimum 20.581
Maximum 20.581
Minimum 20.581
Maximum Deflections for Load Combinations
.-..u..,1lo1lo1...ul.com'l'll~~10W-KIFZ178C-4\TH1R2Z•N.EC6
ENERCALC. INC. 111113,2017, lluld:10.17.8.9, Ver:10.17.8.9
X-X Axis Reaction k
@Base @Top
X-X Axis Reaction
@Base @Top
k
Y -Y Axis Reaction
@Base @Top
Y-Y Axis Reaction
@Base @Top
. . .
Note: Only non-zero reactions are listed.
Mx -End Moments k-11 My-End Moments
@Base @Top @Base @Top
Mx -End Moments k-ft
@Base @Top
My -End Momeni&
@Base @Top
Load Combination Max. X-X Deflection Distsnce Max. Y -Y Deflection Dlstsnce
+D+H 0.0000 in 0.000 ft 0.000 in 0.000 ft
+D+L+H 0.0000 in 0.000 ft 0.000 in 0.000 ft
+O+Lr+H 0.0000 in 0.000 ft 0.000 in 0.000 ft
+D+S+H 0.0000 in 0.000 ft 0.000 in 0.000 ft
+D+0.750Lr+0.750L +H 0.0000 in 0.000 ft 0.000 in 0.000 ft
+D+0.750L +0. 750S+H 0.0000 in 0.000 ft 0.000 in 0.000 ft
+D+0.60W+H 0.0000 in 0.000 ft 0.000 in 0.000 ft
+D+0.70E+H 0.0000 in 0.000 ft 0.000 in 0.000 ft
+D-0.70E+H 0.0000 in 0.000 ft 0.000 in 0.000 ft
+D+O. 750Lr+0. 750L +0.450W+H 0.0000 in 0.000 ft 0.000 in 0.000 ft
M1-18
"< • -\ .
Description : 4) Existing Steel Column
Maximum Deflections for Load Combinations
Load Combination Max. X-X Deflection
+D+0.750L +0. 750S+0.450W+H 0.0000 in
+D+0.750L +0.750S+0.5250E+H 0.0000 in
+D+0.750L +0.750S--0.5250E+H 0.0000 in
+0.60D+0.60W+0.60H 0.0000 in
+0.60D+0. 70E+0.60H 0.0000 in
+0.60D--0.70E+0.60H 0.0000 in
DOnly 0.0000 in
Lr Only 0.0000 in
LOnly 0.0000 in
SOnly 0.0000 in
WOnly 0.0000 in
EOnly 0.0000 in
E Only* -1.0 0.0000 in
HOnly 0.0000 in
Steel Section Pro ertles : Pl e4STD
Depth = 4.500 in !xx
Sxx
Diameter 4.500 in Rxx
Wall Thick = 0.237 in Zx
Area = 2.960 in'2 I yy
Weight = 10.800 plf Syy
Ryy
Veg 0.000 in
4.501n
indows.thomtontomasettl.com\FlleSyslCA2'Prcjects\S5SY5F-BIAnalysia\SEV10W-KIFZ178C-4\lli1R2Z-N.EC6
ENERCALC, INC. 1983-2017, Bulld:10.17.8.9, Ver.10.17.8.9 .
Distance Max. Y -Y Deflection Distance
0.000 fl 0.000 in 0.000 fl
0.000 fl 0.000 in 0.000 fl
0.000 fl 0.000 in 0.000 fl
0.000 fl 0.000 in 0.000 fl
0.000 fl 0.000 In 0.000 fl
0.000 fl 0.000 in 0.000 fl
0.000 fl 0.000 in 0.000 fl
0.000 fl 0.000 in 0.000 fl
0.000 fl 0.000 in 0.000 fl
0.000 fl 0.000 in 0.000 fl
0.000 fl 0.000 in 0.000 fl
0.000 fl 0.000 in 0.000 fl
0.000 fl 0.000 in 0.000 fl
0.000 fl 0.000 in 0.000 fl
= 6.82 in'4 J = 13.600 in'4
= 3.03 in'3
= 1.510 in
= 4.050 in'3
= 6.820 in'4
= 3.030 in'3
= 1.510 in
M1-19