HomeMy WebLinkAbout2525 EL CAMINO REAL; 130; CBC2018-0206; PermitCity of Carlsbad Commercial Permit Print Date: 09/25/2018 Job Address: 2525 El Camino Real, 130 Permit Type: BLDG-Commercial Work Class: Tenant Improvement Status: Parcel No: 1563022700 Lot #: Applied: Valuation: $68,044.13 Reference #: Issued: Occupancy Group: Construction Type: Permit Finaled: U Dwelling Units: Bathrooms: Inspector: Bedrooms: Orig. Plan Check U: Final Plan Check U: Inspection: Project Title: Description: SWEET CLOUD CREAMERY: 1,463 SF TI Permit No: CBC2018-0206 Closed - Finaled 04/13/2018 06/13/2018 MCoII 9/25/2018 3:46:20PM Applicant: Owner: Co-Applicant: JESY ENTERPRISES INC R P I CARLSBAD LP UNIVERSAL CONSTRUCTION THOMAS KIM 3830 Valley Center Dr, 705-648 1114 Avenue Of The Americas, Floor 45 3830 Valley Center Dr, Ste 705-648 SAN DIEGO, CA 92130 New York, NY 10036-7700 SAN DIEGO, CA 92130 619-708-2624 214-660-5232 x215232 858-278-3320 BUILDING PERMIT FEE ($2000+) $490.17 BUILDING PLAN CHECK FEE (BLDG) $343.12 ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL $60.00 MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL $45.00 PLUMBING BLDG COMMERCIAL NEW/ADDITION/REMODEL $71.00 SB1473 GREEN BUILDING STATE STANDARDS FEE $3.00 STRONG MOTION-COMMERCIAL $19.05 Total Fees: $1,031.34 Total Payments To Date: $1,031.34 Balance Due: $0.00 Please take NOTICE that approval of your project includes the 'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as 'fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 1 760-602-2700 1 760-602-8560 f I www.carlsbadCa.gOv C I THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE:[:]PLANNING EIENGINEERING DBUILDING FIRE DHEALTH EJHAZMAT/APCD • Building Permit Application Plan Check No.0Q,f7J3\_¶2O(o Est. Value ) t$4 - 4 City of 1635 Faraday Ave., Carlsbad, CA 92008 Cd1sbad Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit email: building@carlsbadca.gov Date L\ www.carlsbadca.gov -s. JOB ADDRESS - 5 SUITE#/SPACE#/UNIT# APN - 25 CT/PROJECT # LOT # PRASE # A OF UNITS A BEDROOMS J BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE 0CC. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) r j EXISTI USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE AIR CONDITIONING FIRE SPRINKLERS ±. 1 • YESD# NOD YES [—]NO fl YES[::] NO[:] APPLICANT NAME PROPE NER NAME Primary Contact ADDRESS ADDRESS C STATE ZIP CITY STATE ZIP PHONE FAX PHONE FAX EMAIL EMAIL DESIGNOFES CONTRA Ca S Lc ADDRE ADDS e 0 ee1+ u CI STATE ZIP Cl STATE IP PC L- FAX PhEt ) 2FAX 6 (3 EMAIL 1kc, Y'&tiA tLU (S-s cv 1\ STATE LIC. A STAT C. CLASS CITY BUS. LIC.# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permitto construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the - applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License LawiChapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001). .:ARMS Workers' Compensation Declaration: /hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensati n, as reQuiret4 Section 370Q of the Labor Code, for the performance of the work for whictthis permit is issued. My workers' compensation surance ca der and policy number are: Insurance Co. \' P¼'ç1Z t4 C4 Policy No, k_1,3___( Expiration Date ,)1 This section need not be completed if the permit is for one hundred dollars ($100) or ls- I 11 Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' C rnpensation I aws of California. WARNING: Failure to secure workers' corn nsation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hun red thousand dollars (&100,000), in addition to the cost of compensation, dam a pr ' ed for in Section 3706 of the Labor code, interest and attorney's fees. CONTRACTOR SIGNATURE .___L. D AGENT DATE '' IttxwOcie IT I hereby affirm that lam exempt from Contractor's License Law for the following reason: El I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale.If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). [] I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section ______________Business and Professions Code for this reason: I personally plan to provide the major labor and materials for construction of the proposed property improvement. EYes IINo I (have / have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address/ phone /contractors' license number): I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address/ phone / type of work): ..PROPERTY OWNER SIGNATURE ' []AGENT DATE L1c3 n3 Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Yes No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address I certify that l have read the application and state thatthe above information is cornectand that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to buildingconstnjction. I hereby authorize representative of the City of Carlsbad to entoJupon the AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND E)9ENSES OSHA: An OSHA permit is required for excavabons over 5'0',eep and dE EXPIRATION: Every permit issued by the Building OfjI upder the provi 180 days from the date of such permftor if the buildi or)rk authorized ,.APPLICANT'S SIGNATURE specton p09poses. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD UE)dINST SAID CITY INCONSEQUENCE OF THE GRANTING OF THIS PERMIT. xA over 3 stories in height. limitation and become null and void if the building or work authorized by such permit is not commenced within abandoned at any time after the work is commenced fora period of 180 days (Section 106.4.4 Uniform Building Code). DATE \ ' STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. ICERTIFICATE OF OCCUPANCY lCom m e r c i all C Fax (760) 602-8560, Email bUIdinpCarIsbadca.Ov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. r#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX EMAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS PICK UP: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) ASSOCIATED CB# MAIL TO: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) NO CHANGE IN USE/ NO CONSTRUCTION MAIL / FAX TO OTHER: CHANGE OF USE/NO CONSTRUCTION ZAPPLICANT'S SIGNATURE DATE Permit Type: BLDG-Commercial Application Date: 04/13/2018 Owner: R P I CARLSBAD LP Work Class: Tenant Improvement Issue Date: 06/13/2018 Subdivision: CARLSBAD TCT#76-18 Status: Closed - Finaled Expiration Date: 03/25/2019 Address: 2525 El Camino Real 130 Carlsbad, CA 92008-1207 IVR Number: 10725 Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date 09/24/2018 09/24/2018 BLDG-Fire Final 070911-2018 Passed Cindy Wong Complete Checklist item --- COMMENTS Passed FIRE- Building Final No 09/2512018 09/25/2018 BLDG-Final 070915-2018 Passed Paul Burnette Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-Plumbing Final No BLDG-Mechanical Final No BLDG-Structural Final No BLDG-Electrical Final No Complete September 25, 2018 Page 3 of 3 F_7 _t ~ ixf J; - Permit Type: BLDG-Commercial Application Date: 04/13/2018 Owner: R P I CARLSBAD LP Work Class: Tenant Improvement Issue Date: 06/13/2018 Subdivision: CARLSBAD TCT#76-18 Status: Closed - Finaled Expiration Date: 03/25/2019 Address: 2525 El Camino Real 130 Carlsbad, CA 92008-1207 IVR Number: 10725 Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date Checklist Item COMMENTS Passed BLDG-Building Deficiency Walls, see card Yes 08/02/2018 08/02/2018 BLDG-14 065766.2018 Passed Michael Collins Complete Frame/Steel/Bolting! Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-Building Deficiency Suspended hard lid soffits Yes 08/03/2018 08/03/2018 BLDG-17 Interior 065925.2018 Passed Michael Collins Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Soffits Yes BLDG-Building Deficiency Walls, see card Yes 09/06/2018 09/06/2018 BLDG-85 1-Bar, 069190.2018 Failed Michael Collins Reinspection Complete Ceiling Grids, Overhead Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical Not ready No BLDG-44 No Rough-Ducts-Dampers 09/07/2018 09/07/2018 BLDG-85T-Bar, 069367.2018 Failed Paul Burnette Reinspection Complete Ceiling Grids, Overhead Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 09/13/2018 09/13/2018 BLDG-Final 069903.2018 Failed Michael Collins Reinspection Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-Plumbing Final No BLDG-Mechanical Final No BLDG-Structural Final No BLDG-Electrical Final No September 25, 2018 Page 2 of 3 Permit Type: BLDG-Commercial Application Date: 04/13/2018 Owner: R P I CARLSBAD LP Work Class: Tenant Improvement Issue Date: 06/13/2018 Subdivision: CARLSBAD TCT#76-18 Status: Closed - Finaled Expiration Date: 03/25/2019 Address: 2525 El Camino Real 130 Carlsbad, CA 92008-1207 IVR Number: 10725 Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date 09/07/2018 BLDG-85 T-Bar, 069525-2018 Passed Michael Collins Complete Ceiling Grids, Overhead Checklist Item COMMENTS Passed BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers 06/25/2018 06/25/2018 BLDG-21 062016-2018 Underground/Underf loor Plumbing Checklist Item Not ready Not ready Cancelled Michael Collins COMMENTS Yes Yes Yes Yes Yes Reinspection Complete Passed BLDG-Building Deficiency 06/26/2018 06/26/2018 BLDG-21 062160-2018 Underground/Underf loor Plumbing Cherklist Item Cancelled per contractor No Passed Michael Collins COMMENTS Passed Complete BLDG-Building Deficiency BLDG-Building Deficiency 0711012018 07/10/2018 BLDG-14 063656-2018 Frame/Steel/Bolting! Welding (Decks) Checklist Item BLDG-Building Deficiency 07/11/2018 07/11/2018 BLDG-24 063644.2018 Rough/Topout Checklist Item Grease/sanitary waste to POC Cancelled per contractor Failed Michael Collins COMMENTS Not ready Cancelled Michael Collins COMMENTS Yes No Reinspection Complete Passed No Reinspection Complete Passed BLDG-Building Deficiency Not ready, cancelled by contractor No 07/12/2018 07/12/2018 BLDG-84 Rough 063796-2018 Passed Michael Collins Complete Combo(14,24,3444) Checklist Item COMMENTS Passed BLDG-Building Deficiency Walls only Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes 07/17/2018 07/17/2018 BLDG-17 Interior 064170-2018 Partial Pass Michael Collins Reinspection Incomplete Lath/Drywall September 25, 2018 Page 1 of 3 CITY OF CARLSBAD Building Division INSPECTION RECORD, CBC20 18-0206 2525 EL CAMINO REAL # 130 SWEET CLOUD CREAMERY: 1463SFT1 1 INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB CALL BEFORE 3:00 pm FOR NEXT WORK DAY INSPECTION 10 FOR BUILDING INSPECTION CALL: 760-602-2725 OR GO TO: www.Carlsbadcaaov/Building AND CLICK ON "Request Inspection" DATE: ( 1) I2 1563022700 - 4/13/2018 SEP 24 ZOIB çBC2o1 8-0206 CITY OFCARLSBA., If "YES" is please call rrTJr1 760-602-8560, checked below that Division's approval is required prior to requesting a Final Building the applicable divisions at the phone numbers provided below. After all required email to bldginspections@carlsbadcagov or bring in a COPY of this card T( r IF MARKED "YES", IT IS REQUIRED PRIOR TO ANY CONSTRUCTION Inspection. If you have approvals are signed to: 1635 Faraday Ave., o rj -Date Inspector any questions off- fax to Carlsbad. i::rT. STORM WATER PRECON MEETING REGUIRED 760-602-2725 Allow 24 hours IF MARKED "YES", APPROVAL REQUIRED PRIOR TO REQUESTING BUILDING FINAL COPY OF CARD REQUIRED Fire Prevention 760-602-4660 Allow 48 hours lEIi1ITiEi!i.I- Allow Tr;I hours IlU CM&I (Engineering Inspections) 70i:f:91 1iITbefore '..i, Type of Inspection Type of Inspection CODE * BUILDING #11 FOUNDATION - pate ELECTRIC UNDERGROUND El UFER Date Inspector #12 REINFORCED STEEL 777 MASONRY PRE GROUT UGH ELECTRIC / EV CHARGER #66 ELEC SERVICE #32DTEMPORARY ElGROUT ElWALLDRAINS TO VOLTAIC 1 #10 TILT PANELS #38 SIGNS #11 POUR STRIPS BLDG-FINAL #11 COLUMN FOOTINGS Date Inspector #14 SUBFRAME El FLOOR El CEILING #41 UNDERGROUND DUCTS & PIPING #15 ROOF SHEATHING #44 0 DUCT& PLENUM 0 REF. PIPING #13 EXT. SHEAR PANELS #43 H EAT-AIR CON D. SYSTEMS #16 INSULATION BLDG-FINAL #18 EXTERIOR LATH Date Inspector #17 INTERIOR LATH & DRYWALL jo3/tØ' r4- #81 UNDERGROUND (11,12,21,31) BLDG-FINAL #82 DRYWALL,EXT LATH, GAS TES (17,18,23) J 'J I =1 I [c #22 D SEWER &BL/CO DPL/CO Date Inspector #83 ROOF SHEATING, EXT SHEAR (13,15) #84 FRAME ROUGH COMBO (14,24,34,44) O7/(2../( &. #21 UNDERGROUND_/ASTE DWTR fr ,. #85 T-Bar(14,24,34,44) #24 TOP OUT EIWASTE OWTR BLDG- FINALOCCUPANCY #27 TUB & SHOWER PAN l;1 Date Inspector #23 DGASTEST OGASPIPING A/S UNDERGROUND VISUAL #25 WATER HEATER A/S UNDERGROUND HYDRO #28 SOLAR WATER A/S UNDERGROUND FLUSH BLDG-FINAL A/S OVERHEAD VISUAL Irlif 0- .I.) Date Inspector A/S OVERHEAD HYDROSTATIC #51 POOL EXCAV/STEEL A/S FINAL #52 PLUMBING F/A ROUGH-IN f9JjJf ,d #53 ELEC/ CONDUIT/ WIRING F/A FINAL j #54 EQUIPOTENTIAL BOND FIXED EXTINGUISHING SYSTEM ROUGH-IN J #55 PREPLASTER / FENCE/ ALARMS FIXED EXTING SYSTEM HYDROSTATIC TEST #57 GUNITE FIXED EXTINGUISHING SYSTEM FINAL BLDG- FINAL MEDICAL GAS PRESSURE TEST MEDICAL GAS FINAL REV 9/17 SEE BACK FOR SPECIAL NOTES EsGil A SAFEbuiLf Company DATE: 6/8/2018 U A'PLICANT /kJRIS. JURISDICTION: Carlsbad PLAN CHECK #.: CBC2018-0206 SET: IV PROJECT ADDRESS: 2525 El Camino Real #130 PROJECT NAME: Sweet Cloud Creamery Tenant Improvement The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. El The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. LII The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. LII The applicant's copy of the check list has been sent to: EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. 1 / Person contacte&-----yy Telephone #: Date contacted: (Lj/r) Email: Mail Telephone Fax In Person LII REMARKS: 10 By: Jason Pasiut Enclosures: EsGil 6/4/2018 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576 EsGil A SAFEbuar Company DATE: 5/3012018 JURISDICTION: Carlsbad PLAN CHECK #.: CBC2018-0206 SET: III PROJECT ADDRESS: 2525 El Camino Real #130 PROJECT NAME: Sweet Cloud Creamery Tenant Improvement D ,APPLICANT JURIS. The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Corey Pono EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Corey Pono Telephone #: 619-888-9806 Date contacted: '6/'?' (b1 ) Email: coreypono.corico@gmail.com Mail T Ieohàne ' Fax In Person LII REMAR By: Jason Pasiut Enclosures: EsGil 5/24/2018 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad CBC2018-0206 5/30/2018 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. PLANS 2. Each sheet of the plans must be signed by the person responsible for their preparation, even if there are no structural changes. California State Law. There appears to be a trademark label. ALL sheets are required to be signed by the responsible party. Business and Professions Code 5536.1. Please ensure that the sheet index matches the plan sheets. CBC 107.2.1. Set II is missing P0.3 and 0.4. The partial set Ill sheets are not listed on set II or set Ill index. Provide a complete set of plans, signed and corrected indexed with the missing information from number 11 below. Labeling the index properly helps speed up your inspections considerably. PARTITIONS 11. Provide a section view of all new interior partitions. Show: Method of attaching top and bottom plates to structure including fasteners proposed at all new connections of walls, bracing, and soffits to existing construction. Show height of partition and suspended ceiling, and height from the floor to the underside of the floor/ceiling above. There is no dimension showing the height of the walls. Carlsbad CBC2018-0206 5/30/2018 END OF REVIEW To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: LI Yes LI No The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Jason Pasiut at Esgil. Thank you. EsGil A SAFEbuittCompany DATE: 5/18/2018 JURISDICTION: Carlsbad PLAN CHECK #.: CBC2018-0206 SET: II PROJECT ADDRESS: 2525 El Camino Real #130 PROJECT NAME: Sweet Cloud Creamery Tenant Improvement U APLICANT /. J URIS. Lii The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Corey Pono EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Corey Pono,,.. Telephone #: 619-888-9806 Date contacted: - V (by:' ) Email: coreypono.corico@gmail.com Mail )( Telephone Fax In Person REMARKS: By: Jason Pasiut Enclosures: EsGil 5/14/2018 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad CBC2018-0206 5/18/2018 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. PLANS There was no narrative submitted with the re-check explaining the location of updates. 2. Each sheet of the plans must be signed by the person responsible for their preparation, even if there are no structural changes. California State Law. This does not appear to have been addressed. Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: This does not appear to have been addressed. For Mixed Occupancy Buildings, state whether the "nonseparated" or "separated" option was chosen from Sections 508.3/508.4. Please ensure that the sheet index matches the plan sheets. Show location of proposed illuminated exit signs per CBC 1013. This does not appear to have been addressed. Show the location of proposed tactile exit signs per CBC 1013.4 and II13- 703.4.2. This does not appear to have been addressed. PARTITIONS Carlsbad CBC20 18-0206 5/18/2018 9. Wall type G shows re-sawn timber ship lap in this type II building. Please show compliance with CBC 603.1 for the non-combustible properties of this material or remove from design. Provide the ASTM and I or UL listing information along with the manufacturer installation information for this material. Show on the plans how it will be installed per CBC 803.13! 11. Provide a section view of all new interior partitions. Show: Method of attaching top and bottom plates to structure. (NOTE: Top of partition must be laterally braced to roof or floor framing above, unless suspended ceiling has been designed for partition lateral load). Show height of partition and suspended ceiling, and height from the floor to the underside of the floor/ceiling above. Note on the plans whether the glazed partition meets the relative displacement requirements of ASCE 13.5.9. A-C above do not appear to have been addressed. 12. Provide a note on the plans stating: "Penetrations of fire-resistive walls, floor-- ceilings and roof-ceilings shall be protected as required in IBC Section 714." This does not appear to have been addressed. 13. Provide a note stating that, "Floor finishes will be installed per, CBC 804". This does not appear to have been addressed. END OF REVIEW To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: U Yes U No The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Jason Pasiut at Esgil. Thank you. Vt EsGil A SAFEbuittCornpany DATE: 4/24/2018 LI APPLICANT URIS. JURISDICTION: Carlsbad PLAN CHECK #.: CBC2018-0206 SET: I PROJECT ADDRESS: 2525 El Camino Real #130 PROJECT NAME: Sweet Cloud Creamery Tenant Improvement The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Corey Pono EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Corey Pono Telephone #: 619-888-9806 Date contacted:Af*\ (by4tmail: coreypono.corico@gmail.com ail/'t'f'elephone'I/p,, Fax In Person REMARKS: By: Jason Pasiut Enclosures: EsGil 4/16/2018 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad CBC20 18-0206 4/24/2018 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK #.: CBC2018-0206 OCCUPANCY: A2, Si, Fl, B TYPE OF CONSTRUCTION: IlA ALLOWABLE FLOOR AREA: SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 4/13/2018 DATE INITIAL PLAN REVIEW COMPLETED: 4/24/2018 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad USE: Ice Cream Shop ACTUAL AREA: 1,463sf STORIES: 1 HEIGHT: unchanged OCCUPANT LOAD: 51 DATE PLANS RECEIVED BY ESGIL CORPORATION: 4/16/2018 PLAN REVIEWER: Jason Pasiut This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2016 CBC, which adopts the 2015 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBC20 18-0206 4/24/2018 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92006, (760) 602- 2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. PLANS Provide the names, addresses and telephone numbers of the owner and the responsible design professionals on the Title Sheet. Sec. 107.2. 2. Each sheet of the plans must be signed by the person responsible for their preparation, even if there are no structural changes. California State Law. Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: For Mixed Occupancy Buildings, state whether the "nonseparated" or "separated" option was chosen from Sections 508.3/508.4. Please ensure that the sheet index matches the plan sheets. . ACCESSIBILITY FOR REMODELS, ADDITIONS, AND REPAIRS The following disabled access items are taken from the 2016 edition of California Building Code. Per Section 1.9.1.2, all privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities. Where existing elements or spaces are altered, each altered element or space shall comply with applicable requirements of Division 2, including CBC section 11 B-202.4. CBC section 11 B-202.4 states that when alterations or additions are made to existing buildings, an accessible path of travel to the specific area of alteration shall be provided. See exceptions to 11 B-202.4. Detail on the plans the following elements of the existing path of travel that are required to comply with the 2016 accessibility standards: 4. Existing primary entrance to the building or facility, including: Carlsbad CBC20 18-0206 4/24/2018 Show the existing accessible parking dimensions, slope, and cross-slope in compliance with CBC 11 B-502. Show the existing curb ramp (if any) 48" minimum width, 48" x 48" turning space at the bottom, landing length of 48" at the top, slope and cross-slope in compliance with CBC 11 B-406. Show the existing ramp (if any) slope, cross-slope, 48" minimum width, 60" x 60" landing at the top, 72" long landing at the bottom, compliant changes in direction (60" x 72") in compliance with CBC 11 B-405. Show the existing stair (if any) width, riser and tread dimensions, contrasting stipes, handrail height, gripping surfaces and top/bottom extensions in compliance with CBC 11 B-504 and 505. Show the existing accessible entrance door hardware, door width, and maneuvering clearances on either side of the door in compliance with CBC 11B-206.4. Show the existing elevator door clear width, car control buttons, car position indicators, and emergency communication systems in compliance with 11 B- 407. Proposed toilet facilities that serve the remodeled area shall be shown to comply with the accessibility details on sheet A 003.00. Please provide detail call outs at the floor plan for accessible restroom details on sheet A 003.00 Existing signage at parking stall, building entrance, route to accessible features and the accessible features themselves. Existing accessible parking identification. 11 B-502.6, 11 B-502.6.2, 11 B- 502.8. Existing accessible parking surface identification. 11 B-502.6.4.1. Existing access isle "NO PARKING" identification per 11 B-502.3.3 Entrances in compliance with 11 B-404 shall be marked with the International Symbol of Accessibility, installed per 11 B-703.6. 11B-216.6. I) Non-compliant entrances shall be marked with a directional sign, with visual characters, indicating the location of the nearest compliant entrance. ii) Accessible entrance sign not required if all entrances into the space comply with 11 B-404. Show location of proposed illuminated exit signs per CBC 1013. Carlsbad CBC2018-0206 4/24/2018 Show the location of proposed tactile exit signs per CBC 1013.4 and 1113- 703.4.2. Compliant restrooms marked with signs per 11 B-703.7.2.6.3, including braille and the International symbol of accessibility. 11 B-216.8. AB1732 Section 1, Article 5:118600: All single-user toilet facilities in any business establishment, place of public accommodation, or state or local government agency shall be identified as all-gender toilet facilities by signage that complies with Title 24 of the California Code of Regulations, and designated for use by no more than one occupant at a time or for family or assisted use. The location of and directions to the compliant restrooms shall be posted in or near the building entrance and shall include the International symbol of accessibility. 11 B-216.8. Show that the dry food, candy and beverage dispensers available for public use are within the reach ranges of 11 B-308. Show that the glass block service counter meets the following: a) The counter surface for parallel or forward approach shall be 36" long with a height of 34" maximum. Counters designed for parallel approach shall have knee and toe clearance per 11 B-306. 1113- 904.4.1 and 2. PARTITIONS Wall type G shows re-sawn timber ship lap in this type II building. Please show compliance with CBC 603.1 for the non-combustible properties of this material or remove from design. Please provide further detail for the proposed connection of the exterior store front to the existing structure. Sheet A 300.00 detail 3 and sheet A 613.00. Provide a section view of all new interior partitions. Show: Manufacturer and approval number of metal studs or indicate "to be [CC approved". Method of attaching top and bottom plates to structure. (NOTE: Top of partition must be laterally braced to roof or floor framing above, unless suspended ceiling has been designed for partition lateral load). Show height of partition and suspended ceiling, and height from the floor to the underside of the floor/ceiling above. Carlsbad CBC20 18-0206 4/24/2018 d) Note on the plans whether the glazed partition meets the relative displacement requirements of ASCE 13.5.9. Provide a note on the plans stating: "Penetrations of fire-resistive walls, floor-- ceilings and roof-ceilings shall be protected as required in IBC Section 714." Provide a note stating that, "Floor finishes will be installed per CBC 804". Sheet A 613.00 detail Al has a call-out for detail A3 on sheet A572 which is not present in the plans. Please clarify. . PLUMBING Please show that the potable water supply to beverage dispensers, carbonated beverage dispensers, or coffee machines are protected by a legal airgap, a vented back flow preventer, or a reduced pressure principle backflow preventer. The relief valve shall drain indirectly into the sewer with a legal airgap. CPC 603.5.12. Please show that potable water outlets with hose attachments, such as at the mop sink, are protected by a nonremovable hose bib-type backflow preventer, a nonremovable hose bib-type vacuum breaker, or by an atmospheric vacuum breaker installed not less than 6 inches (152 mm) above the highest point of usage located on the discharge side of the last valve. CPC 603.5.7. Please show on the plumbing plan that the drainage piping is vented by means of one or more vent pipes with an aggregate cross-sectional area that is not less than that of the sewer pipe. CPC 904.1. END OF REVIEW To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: U Yes U No The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Jason Pasiut at Esgil. Thank you. Carlsbad CBC2018-0206 4/24/2018 (DO NOT PAY - THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK #.: CBC2018-0206 PREPARED BY: Jason Pasiut DATE: 4/24/2018 BUILDING ADDRESS: 2525 El Camino Real #130 BUILDING OCCUPANCY: A2 BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) 1463 46.51 68,044 Air Conditioning Fire Sprinklers TOTAL VALUE 68,044 Jurisdiction Code lOB IBY Ordinance I 1997 UBC Building Permit Fee V 1997 UBC Plan Check Fee V Type of Review: LI Complete Review LI Structural Only Repetitive Fee Repeats El Other LI Hourly Hr. © * EsGil Fee I $276.60! Comments: Sheet 1 of 1 DIVISION: 090000—FINISHES SECTION: 099643—FIRE-RETARDANT COATINGS REPORT HOLDER: NORTHEAST FIRESHIEW, INC. 25 CARLOUGH ROAD BOHEMIA, NEW YORK 11716 Pit 2 2018 EVALUATION SUBJECT: INSPECTA-SHIELD PLUS TM FIRE-RETARDANT COATING ICC ICC ICC C PMG LISTED Look for the trusted marks of Conformity! "2014 Recipient of Prestigious Western States Seismic Policy Council (WSSP() Award in Excellence" A Subsidiary of r scc Aw.dit.d \ I I specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not (iiij recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as *cdPMF=I to any finding or other matter in this report, or as to any product covered by the report. (JTTF411I 1ete ccw J Copyright 0 2016 ICC Evaluation Service, LLC. All rights reserved. qmo3 ICC-ES Evaluation Report ESR-2019 Reissued August 2016 This report is subject to renewal August 2017. www.icc-es.orq I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 0900 00—FINISHES Section: 09 96 43—Fire-Retardant Coatings REPORT HOLDER: NORTHEAST FIRESHIELD, INC. 25 CARLOUGH ROAD BOHEMIA, NEW YORK 11716 (631) 563-0960 www.northeastfireshield.com info(northeasthreshieId.com EVALUATION SUBJECT: INSPECTA-SHIELD PLUSTM FIRE-RETARDANT COATING 1.0 EVALUATION SCOPE Compliance with the following codes: 2012, 2009 and 2006 International Building Code® (IBC) 2012, 2009 and 2006 International Residential Code® (IRC) 2012, 2009 and 2006 International Fire Code® (IFC) 2012, 2009 and 2006 International Existing Building Code® (lEBC) Property evaluated: Surface-burning characteristics 2.0 USES Irispecta-Shield Plus is a fire-retardant coating, as defined in IFC Section 803.4 that is field-applied by applicators certified by Northeast Fireshield, Inc., to exposed surfaces of unfinished plywood and dimensional white pine lumber as an interior finish in the interior of new and existing construction to achieve the flame-spread and smoke-developed indices required by the applicable code. 3.0 DESCRIPTION The surface to be coated must be free of dust, dirt, oil, paint, stain, varnish or sealant. The product is not for use on surfaces that may be subjected to washing or sustained humidity of 80 percent or more. The product must be thoroughly mixed before being transferred to the spray apparatus and prior to application. The product is applied by air-spray application in one coat. The air temperature for application shall be limited to a minimum of 33°F (0.6°C) and a maximum of 120°F (490C). The maximum moisture content for the substrate is 25 percent. The cure time for the fire-retardant coating is 48 hours. 4.2 Application and Surface Burning Characteristics: When applied to dimensional white pine lumber or unfinished plywood at a coverage rate of 300 square feet per gallon (7.36 m2/L) with a dry film coating thickness of 3 mils [0.003 inch (0.09 mm)], the product provides a flame-spread index of 25 or less and a smoke-developed index of 200 or less when tested in accordance with ASTM E84, and qualifies as a Class A finish in accordance with IBC Section 803.1, IFC Section 803.1.1, and NFPA 703. The flame-spread and smoke-development indices are applicable when the coating is overcoated with two layers of acrylic paint or one layer of wood stain overcoated with one layer of polyurethane. 4.3 Field Test: An ultraviolet chemical is added to the product for the purpose of aiding in the identification of the product after application. This chemical makes the product visible using a black light after the product has dried for 48 hours. 5.0 CONDITIONS OF USE The Inspecta-Shield Plus'TM fire-retardant coating described in this report complies with, or is a suitable alternative to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: Inspecta-Shield Plus is a colorless chemical finish for 5.1 Installation must comply with this report, the interior use. The product comes in 1-quart (1.0 L), 1-gallon manufacturer's published instructions and the (3.8 L), and 5-gallon (18.9 L) containers and 55-gallon (208 applicable code. In the event of a conflict between the L) drums with a shelf life of two years from the date of manufacturer's published installation instructions and manufacture when the containers are unopened. this report, this report governs. 4.0 INSTALLATION 5.2 Application must be limited to construction of the 4.1 General: specific substrates set forth in Section 2.0, to exposed Installation of Inspecta-Shield Plus interior locations having a sustained humidity of less must comply with this than 80 percent. report and the manufacturer's published installation instructions. The manufacturer's published installation 5.3 Field testing must be performed by the certified instructions must be available at the jobsite at all times applicator, as indicated in Section 4.3, when required during installation, by the code official. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other mailer in this report, or as to any product covered by the report. I,LvvwvL cwa Copyright 0 2016 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 2 ESR-201 9 I Most Widely Accepted and Trusted Page 2 of 2 5.4 A manufacturer's Certificate of Flameproofing, as shown in Figure 1, must be submitted by the certified applicator to the code official, describing the material treated; the location of the treated materials, including the square footage of the area treated; and the application rate. 5.5 Special inspections may be required when determined to be necessary by the code official in accordance with Section 1705.1.1 of the 2012 IBC, Section 1704.15 of the 2009 IBC, or Section 1704.13 of the 2006 IBC, as applicable 5.6 The coating is manufactured in Dracut, Massachusetts, under a quality control program with inspections by ICC-ES. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Surface-applied Fire-retardant Coatings (AC363), dated February 2007, editorially revised March 2012. 7.0 IDENTIFICATION Containers of Inspecta-Shield Plus are identified by a label bearing the manufacturer's name (Northeast Fireshield, Inc.) and address, the product name, the date of manufacture, shelf life, the manufacturer's instructions for application, and the evaluation report number (ESR-2019). FIGURE 1—MANUFACTURER'S CERTIFICATE OF FLAMEPROOFING BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE Erosion Control Sediment Control BMPs Tracking Non-Storm Water Waste Management and Materials BMPs Control BMPs Management BMPs Pollution Control BMPs LI .2 i Ii is Best Management Practice* - , - . .iii (BMP) Description a .t -mom m L. fi 0 B'- kt' =0.0 ta c kt0 -'n oo bo u, ç) 1 0 a,> (I) (I) a. .E u m Q Q_ Q a. > Cs M0) u u o a,M M 0 CASQA Designation - T T T T °00 Construction Activity - Grading/Soil Disturbance - - - - - - - - - - - - - - - - - - - Trenching/Excavation - - - - - - - - - - - - - - - - - - - Stockpiling - - - - - - - - - - - - - - - - - - Drilling/Boring - - - - - - - - - - - - - - - - - - - Concrete/AsphaltSawcutting -- - Concrete Flotwork -- Paving - - - - - - - - - - - - - - - - - - Conduit/Pipelnstollotion - - - - - - - - - - - - - - - - - - Stucco/Mortar Work -- -- Waste Disposal - Staging/LayDown Area -- -- - - - - - - - - - - - - - - - - - - Equipment Maintenance and Fueling Hazardous Substance Use/Storage — Dewatering — — - - - - - - - - - - - - - - - F—ISite Access Across Dirt -- Other (list): -- - - - - - - - - - - - - - - - Instructions: Check the box to the left of all applicable construction activity (first column) expected to occur during construction. Located along the top of the BMP Table is a list of BMP's with it's corresponding California Stormwater Quality Association (CASQA) designation number. Choose one or more BMPs you intend to use during construction from the list. Check the boo where the chosen activity row intersects with the BMP column. Refer to the CASQA construction handbook for information and details of the chosen BMPs and how to apply them to the project. SHOW THE LOCATIONS OF ALL CHOSEN BMPs ABOVE ON THE PROJECTS SITE PLAN/EROSION CONTROL PLAN. SEE THE REVERSE SIDE OF THIS SHEET FOR A SAMPLE EROSION CONTROL PLAN. Page 1 of 1 PROJECT INFORMATION Site Address: Assessor's Parcel Number: Emergency Contact: Name: 24 Hour Phone: Construction Threat to Storm Water Quality (Check Boo) 0 MEDIUM 0 LOW REV STORM WATER COMPLIANCE FORM TIER I CONSTRUCTION SWPPP CB E-29 SW STORM WATER POLLUTION PREVENTION NOTES ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION OF EROSION AND SEDIMENT CONTROL BMPs WHEN RAIN IS EMINENT. THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION• CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY INSPECTOR AFTER EACH RUN—OFF PRODUCING RAINFALL THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY INSPECTOR DUE TO INCOMPLETE GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PECENT (407). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM AGGREGATE. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST BE INSTALLED AND MAINTAINED. THE CITY INSPECTOR SHALL HAVE THE AUTHORITY TO ALTER THIS PLAN DURING OR BEFORE CONSTRUCTION AS NEEDED TO ENSURE COMPLIANCE WITH CITY STORM WATER QUALITY REGULATIONS. OWNERS CERTIFICATE: I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO AVOID THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO AVOID THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED POLLUTANTS; AND (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP THROUGHOUT THE DURATION OF THE CONSTRUC11ON ACTIVITIES UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED BY THE CITY OF CARLSBAD. OWNER(S)/OWNER'S AGENT NAME (PRINT) OWNER(S)/OWNER'S AGENT NAME (SIGNATURE) DATE E-29 Maliff UNIT PARAUNG QF LEGEND SETBACK \ f LINE \, TOLL It' DESCRIPTION * DWG.NO. SYMBOL QUANTITY F'(I IOWAN cYIL5-' '-5'1 PROPERTY UNE IF INLETS RIO INSTALLED I AND FIJNCIII3EEIL, BUT I SILT FENCE SE-I -0-0-- THE CONSIROCIION ORE IS UNFINISHED. PROISOT FIBER ROLL SE-5 —X—X—X—x— INLETS PER SE-ID, PRESERVATION OF TX/SIlO/C OF EC-2 PRESERVAWN INLET PR07EC710N SE-10 DIISITNO EUDLIA lION HERONS PER EC-2, GRAVEL BAG BERM/BARRIER SE-6 CC2C2IZXT DIRECTION/COURSE OF FLOW HYDRAULIC MULCH/HYDROSEED EC-1. EC-4 STABILIZED CONSTRUCTION ENTRANCE Ti?- I MATERIALS DELIVERY AND STORAGE AREA WM- I TEMPORARY TRASH/SOLID WASTE WM-5 HAZARDOUS AND CONCRETE WASTE MANAGEMENT WM-5, WI/-B \ \, SANITARY WASTE WM-9 WM-9 \ \ (PORTABLE TOILET) , \ \-STANDARD DRAWINGS (SE-S. WM-5, ETC.) CAN BE FOUND AT THE CALIFORNIA STORM WATER QUALITY ASSOCIATION (CASQA) WEBS/OR: \\\ \ http://www.cobmphandt'ooks.00m/ WIN LEVEL ADDISON F53508 xx a xx xx xx SCALE: 4 STORM OP,RN FORCE 8011418 STOVES \ 1212 BROOKS BOX FOR I1EINSIODN TO 0184117fl' FLOW (IVE) I' 8' SOLID PROPERTY UNE TOLL - kU _I" is A N IL T7 5.55' ROLLED ISRB OLRnON PER DETRS 0 - GIMLET 9465 Al PER SE-6, ELISE ROTHSCHILD (CO U itt ) Of q§an t E ] 0 AMY HARBERT Director Assistant Director DEPARTMENT OF ENVIRONMENTAL HEALTH FOOD AND HOUSING DIVISION RE C E V ED P.O. BOX 129261, SAN DIEGO, CA 92112-9261 Phone: (858) 505-6659 FAX: (858) 505-6824 JUN 0 5 2018 1 (800) 253-9933 www.sdcdeh.org CITY OF CARLSBAD PLAN APPROVAL SHEET BUILDING DIVISION DBA: SWEET CLOUD CREAMERY DATE:5/31 /2018 SITE: 2525 EL CAMINO REAL #130 CARLSBAD 92008 PC #: DEH2018-FFPP-009554 BUSINESS OWNER: SAA Plans are approved contingent upon the following: Department of Environmental Health (DElI) stamped plans shall be maintained at the jobsite and available for review at hetme Oftheinpection. Changes to equipment layout, menu, or application must be submitted for approval. Changes made without approval will make the plan approval null and void. Obtain local Building Department and all applicable agencies perrmts and approvals PRIOR TO FINAL INSPECTION AND APPROVAL TO OPERATE BY THIS DEPARTMENT 4) All food and utensil-related equipment shall be certified to applicable sanitation standards by an ANSI accredited testing agency. 5) Upon completion of 50%-80% of construction, call (858) 505-6660 to schedule an inspection. In lieu of a plumbing inspection by DEH, ensure that the plumbing is constructed to these standards: Floor sinks shall be installed ¼ exposed and equipped with an appropriate grill cover if no access is provided for cleaning. Drain lines shall slope ¼" per foot, shall not exceed 15' in length and shall terminate a minimum of 1" above the floor sink with a legal air gap or otherwise approved by the enforcing agency. Drain lines shall not intersect walkways or door ways. C. No condensate drainage of any kind can drain to the mop sink. 3-compartment sinks, preparation sinks, dump sinks, and any other plumbed equipment must drain indirect to a floor sink. Grease traps/interceptors, if required by the local waste water authority must be located outside of the food preparation, food storage, or warewashing areas. Floor surfaces must be sloped 1:50 to required floor drains. Conduits of all types shall be installed within walls as practicable. When otherwise installed, they shall be mounted or enclosed in a chase so as to facilitate cleaning. 6) Owners and/or operators must pass an approved and accredited Food Safety Certification course. Proof of successful completion of this course is to be furnished at the final inspection. 7) All equipment is to be in place and functional. At the time when the final inspection is requested, the facility shall have all utilities operational and all refrigeration shall have an ambient air temperature of 38'F or below and shall be equipped with a thermometer accurate to +/- 20F in the warmest section of the unit. 8) Seal all cracks, gaps and crevices in counters, cabinets, around metal flashing, sink backsplashes, around pipes and conduits with silicone sealant. 9) AN AIR BALANCE REPORT IS REQUIRED IF THE FACILITY HAS VENTILATION HOODS._____________ 10) ANY FOOD PROCESSING AREAS MUST BE COMPLETELY ENCLOSED OPERABLE WINDOWS MOVEABLE Plans reviewed by: Celeste Penn, REHS CALL (858) 505-6660 AT LEAST 10 WORKING DAYS IN ADVANCE TO SCHEDULE INSPECTIONS. A FINAL INSPECTION MUST BE CONDUCTED AND AN ENVIRONMENTAL HEALTH PERMIT SHALL BE ISSUED PRIOR TO OPENING AND OPERATING THIS FOOD ESTABLISHMENT. "Environmental and public health through leadership, partnership and science" DATE: 21 MAY 2018 JURISDICTION: CARLSBAD PLAN CHECK: CBC2018-0206 PROJECT ADIJRESS: 25 El Camino Real #130 PROJECT NAME: Sweet Cloud Creamery Tenant Improvement RECEIVED MAY Z 2 2018 CITY OF CARLSBAD BOLT UILDtNG DIVISION DESIGN GROUP PLAN CHECK RESPONSE: 2 - Plans are signed by State of California Licensed Contractor 3 - Provide a Building Code Lefend on the Title Sheet. Include the Following code information for each building proposed: For Mixed Occupancy Buildings, state whether the "nonseparated" or "Separated" optoin was chosen (Nonseparated indication was noted on Cover Sheet - A000.00) Please Ensure Index Matches the plan sheets See All Sheets See A000.00 See A 000.00 E - Show Location of porposed Illuminated exit signs per CBC 1013. (Exit Locations where located on RCP - see sheet A200.01 See A200.01 F - Show the location of p[roposed tactile exit signs pwer CBC 1013.4 and 11 B 703.4.2 (Tactile Exit Sign Locations were addeed to Floor PLan - see sheet A 100.02 See A 100.02 9 - Wall Type F Shows Re-Sawn Timber Ship lap in this Type II Building. Please show compliance with CBC 603.1 for the non cpmbustible properties of this material or remove from design. (Fire-Rated documentation has been provided by the manufacturer indicating compliac- See A 102.01 ne with CHC603.1 and CBC 803.13 See Addendum #1 11 - Provide a section view of all new Interior Partitions: method for attaching top and bottom plates to structure ____________________________________________See A600.01 show height of partition and suspended ceiling from the floor to the inderside of the floor ceiling above See [2] A600.01 Note on plans whether the glazed partition meets the relative displacement requirements of ASCE 13.5.9 See A100.02 Provide a note on the plans stating: "Penetrations of fire-resistive walls, floor, ceilings and roof-ceilings shall be protected as required in ibc section 714 Note added to floor plan 7 see sheet A100.02 See A 100.02 Provide a note stating that, "Floor Finishes will be installed per CBC 804" Note added to floor finish plan - see sheet A 700.02 _____________________________________________See A103.01 SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY RECORD ID# PLANCHECK# BP DATE I Business Name Business Contact Telephone # Sweet Cloud SD LLC DBA Sweet Cloud Creamery Khushal Morjaria 760-556-8497 Project Address (include suite) City State Zip Code APN# Shoppes at Carlsbad. Space 131b, 2525 El Camino Real Carlsbad CA 92008 Mailing Address (include suite) City State Zip Code Plan File# Shoppes at Carlsbad, Space 131b, 2525 El Camino Real Carlsbad CA 92008 Project Contact Applicant E-mail Telephone # Khushal Morjaria - khush@sweetcloudcreamery.com 760-556-8497 I ne roiiowing questions represent tne Tacility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT - HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: (not required for prolects within the City of San Diego): Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: A2 51 max Facility's Square Footage (including proposed project): 1463sq ft Explosive or Blasting Agents 5. Organic Peroxides 9—Water-Reatives Compressed Gases 6, Oxidizers (j0. Cryogenics) Flammable/Combustible Liquids 7. Pyrophorics 1Highly1c or Toxic Materials Flammable Solids 8. Unstable Reactives 12. Radioactives Corrosives Other Health Hazards None of These. III 6 PART It: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISION (HMD questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Avenue, Suite 110, Si Call (858) 505-6700 prior to the issuance of a building permit. FEES ARE REQUIRED Project Completion Date: 22 July 2018 Expected Date of Occupancy: 1 Aug 2018 YES NO (for new construction or remodeling projects) D 0 Is your business listed on the reverse side of this form? (check all that apply). 0 Will your business dispose of Hazardous Substances or Medical Waste in any amount? ED Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 pounds and/or 200 cubic feet? 0 Will your business store or handle carcinogens/reproductive toxins in any quantity? 0 Will your business use an existing or install an underground storage tank? 0 Z Will your business stare or handle Regulated Substances (CalARP)? fl Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? 0 Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act). the answer to any of the Diego, CA 92123. 0 CalARP Exempt Date Initials El CalARP Required Date Initials El CalARP Complete Date Initials PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCD): The following questions are intended to identify the majority of air pollution issues at the planning stage. Your project may require additional measures not identified by these questions. Some residential projects may be exempt from APCD requirements. For more comprehensive requirements, please contact APCD at apcdcompsdcounty.ca.cjov; (858) 586-2650; or 10124 Old Grove Road, San Diego, CA 92131. YES NO 0 Will the project disturb 100 square feet or more of existing building materials? 0 Will any load supporting structural members be removed? If yes, contact APCD prior to issuance of a building or demolition permit A notification may be required at least 10 working days prior to commencing demolition. 0 0 (ANSWER ONLY IF QUESTION I or 2 IS YES) Has an asbestos survey been performed by an individual that has passed an EPA-approved building inspector course? 0 0 (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Based on the survey results, will the project disturb any asbestos containing material? If yes, contact APCD prior to the issuance of a building or demolition permit. A notification may be required at least 10 working days prior to commencing asbestos removal. 0 0 Will the project or associated construction equipment emit air contaminants? See the reverse side of this form for typical equipment requiring an APCD permit If yes, contact APCD prior to the issuance of a building permit. 0 0 (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school boundary? Briefly describe business activities: Briefly describe proposed project: Nitrogen cooled Ice Cream Retail Store I Remodelling an exisiting space within the mall I declare under penalty of perjury that to the best of my knowledge and belief tHe responses made herein are true and correct. - - - KHUSHAL MORJARIA -DIDOE; 05/11/2018 Name of Owner or Authorized Agent Signature of Owner or Author zed Agent Date FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:_____________________________________________________________________ BY: DATE: EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOL!YILUING PERMIT BUT-'NOT-FOR OCCUPANCY RELEASEOFOR OCCUPANCY— COUNTY-HMD APCD .6T'&d4 APCD COUNTY-HMD APCD 'l*I' REVIWD j 5/?L A stamp in this box only exempts businesses from compl or y1atin a H dous Materials Business Plan. Other permitting requirements may still apply Af HM-9171 (12/17) 'S iJ.niiA. San WieaoUDEN - Hazardous Materials Division I INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY ENCJNA WASTEWATER AUTHORflY s-fl 0 Date Business Nae Street Address Email Address PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) Check all below that are present at your facility: Acid Cleaning Ink Manufacturing Nutritional Supplement/ Assembly Laboratory Vitamin Manufacturing Automotive Repair Machining / Milling Painting / Finishing Battery Manufacturing Manufacturing Paint Manufacturing Biofuel Manufacturing Membrane Manufacturing Personal Care Products Biotech Laboratory (i.e. water filter membranes) Manufacturing Bulk Chemical Storage Metal Casting! Forming Pesticide Manufacturing! Car Wash Metal Fabrication Packaging Chemical Manufacturing Metal Finishing Pharmaceutical Manufacturing Chemical Purification Electroplating (including precursors) Dry Cleaning Electroless plating Porcelain Enameling Electrical Component Anodizing Power Generation Manufacturing Coating (i.e. phosphating) Print Shop Fertilizer Manufacturing Chemical Etching ! Milling Research and Development Film tX-ray Processing Printed Circuit Board Rubber Manufacturing Food Processing Manufacturing Semiconductor Manufacturing Glass Manufacturing Metal Powders Forming Soap/ Detergent Manufacturing Industrial Laundry Waste Treatment/ Storage SIC Code(s) (if known): Brief description of business activities (Production / Manufacturing Operations):_______________ Description of operations generating wastewater (discharged to sewer, hauled or evaporated): Estimated volume of industrial wastewater to be discharged (gal /day): List hazardous wastes generated (type / volume): Date operation began/or will begin at this location: / Have you applied /or a Ws'tate't\Di from the Encina Wastewater Authority? Yes No / If yes,whç: \ V Title Phone No. Site Avenida Encinas Carlsbad, CA 92611 (MO) 498- 4 Signature . 1tL0jLljH0KIT'Y, 6200 ENCINAW S FAX: (760) 476-9852 Hollianne Holmes From: Khushal Morjaria <khush@sweetcloudcreamery.com > Sent: Monday, June 11, 2018 11:43 AM To: Building Cc: bhavin@sweetcloudcreamery.com; thomas_sduniversal@live.com Subject: Plan check number CBC2018-0206 - CHANGE OF DETAILS Dear Sir! Madam My name is Khushal Morjaria - one of the owners of Nitrocream LLC and Sweet Tooth SD LLC Please take this email as confirmation that Thomas from Universal Construction has been awarded the construction jobs and will be taking over the submission of permits for Sweet Cloud Creamery for the following spaces from Corey Pono: Unit 131b 2525 El Camino Real Carlsbad , CA, 92008 Unit 141 555 Broadway, Chula Vista , CA, 91910 If there are any questions or concerns please call me on 7605568497 Kind regards, Khushal Morjaria Director - Sweet Cloud Creamery This message and any files transmitted with it is intended for the addressee only and may contain information that is confidential and/or legally privileged. Unauthorised use is strictly prohibited and may be unlawful. If you are not the addressee, you should not read, copy, disclose or otherwise use this message, including any picture or graphic and any attachment, except for purpose of delivery to the addressee. We make every effort to keep our network free from viruses however you do need to verify this email and any attachments to it to be virus free as we can take no responsibility for any computer virus which might be transferred by way of this email. — ~- t. R. U Q C1117 of Qhshwd Print Date: 09/26/2018 Permit No: PREV2018-0190 2525 El Camino Real, 130 BLDG-Permit Revision 1563022700 $0.00 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: Description: Work Class: Residential Permit Revisi Status: Closed - Finaled Lot U: Applied: 07/10/2018 Reference U: Issued: 08/21/2018 Construction Type Permit 09/26/2018 Finaled: Bathrooms: Inspector: MColl Orig. Plan Check : CBC2018-0206 Final Plan Check U: Inspection: SWEET CLOUD CREAMERY: CHANGE 5/8' DRYWALL FROM 2 LAYERS TO 1 LAYER Applicant: Owner: Contractor: JESY ENTERPRISES INC R P I CARLSBAD LP UNIVERSAL CONSTRUCTION THOMAS KIM 3830 Valley Center Dr, 705-648 1114 Avenue Of The Americas, Floor 45 3830 Valley Center Dr, Ste 705-648 SAN DIEGO, CA 92130 New York, NY 10036-7700 SAN DIEGO, CA 92130 619-708-2624 214-660-5232 x215232 858-278-3320 FEE AMOUNT MANUAL BUILDING PLAN CHECK FEE $168.75 Total Fees: $ 168.75 Total Payments To Date : $ 168.75 Balance Due: $0.00 Building Division 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov PLAN CHECK REVISION OR Development Services (City of DEFERRED SUBMITTAL Building Division Carlsbad APPLICATION 1635 Faraday Avenue 760-602-2719 B-I 5 www.carlsbadca.gov Original Plan Check Number C i (. (-) (S-0-1 06 Plan Revision Number Proiect Address 2 L C4\ . C'U\ h p( c - - General Scope of Revision/ reçl Submittal: 1 62. 02 CONTACT INFORMATION- V V V Name Vv'-\ VV-v Phone __ tL Fax Address _0\aJ4A,C_tuioc-LuCity o.-C _Zip(j4_L Email Address J.N\—c '' 4L&O iiC'-t--4)J-L_ Ue - Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1. Elements revised: LI Plans LII Calculations Lii Soils El Energy [I] Other 2. Describe revisions in detail 3. List page(s) where each revision is shown - L-Q_4v eP Ci Die _L7 PcI o kL-2 Does this revision, in any way, alter the exterior of the project? Yes No Does this revision add ANY new floor area(s)? LI Yes No 6., Does this revision affect any fire related issues? El Yes (No 7. Is this a complete Se? Yes 1-.No I ~Signature Date _\_ os 1635 Faraday Avenue, Carlsbad, CA 92008 t: 760-602- 2719 f: 760-602-8558 Email: building@carlsbadca.gov www.carlsbadca.gov EsGil A SAFEbuiLtCompany DATE: 8/1/2018 U APPLICANT U JURIS. JURISDICTION: Carlsbad PLAN CHECK #.: CBC2018-0206.rev SET: II PROJECT ADDRESS: 2525 El Camino Real #130 PROJECT NAME: Sweet Cloud Creamery Wall Revision The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. El The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. El The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. Lii The applicant's copy of the check list has been sent to: EsGil staff did not advise the applicant that the plan check has been completed. LI EsGil staff did advise the applicant that the plan check has been completed. Person contacted: / Telephone Date contacted:/' (bYS9) Email: Mail Telephone Fax In Person LII REMARKS: By: Jason Pasiut Enclosures: EsGil 7/26/2018 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil A SAFEbui1tCompany DATE: 7/18/2018 U APPLICANT JURISDICTION: Carlsbad pEVc309° A JURIS. PLAN CHECK #.: CBC2018-0206.rev SET: I PROJECT ADDRESS: 2525 El Camino Real #130 PROJECT NAME: Sweet Cloud Creamery Wall Revision The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. LII The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Tom Kim LI EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed Person contacted: Tom Kim Date acted:71W1(g (by-4 ~aii~Teiep~hon Fax In Person REMARKS: By: Jason Pasiut EsGil 7/12/2018 Telephone #: 619-708-2624 Email: thomas_sduniversal@live.com Enclosures: 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad CBC20 18-0206.rev 7/18/2018 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS JURISDICTION: Carlsbad USE: Ice Cream Shop ACTUAL AREA: 1,463sf STORIES: 1 HEIGHT: unchanged OCCUPANT LOAD: 51 DATE PLANS RECEIVED BY ESGIL CORPORATION: 7/12/2018 PLAN REVIEWER: Jason Pasiut PLAN CHECK #.: CBC2018-0206.rev OCCUPANCY: A-2, S-1,F-1, B TYPE OF CONSTRUCTION: II-A ALLOWABLE FLOOR AREA: within SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 7/10/2018 DATE INITIAL PLAN REVIEW COMPLETED: 7/18/2018 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2016 CBC, which adopts the 2015 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBC2018-0206.rev 7/18/2018 [DO NOT PAY - THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK #.: CBC2018-0206.rev PREPARED BY: Jason Pasiut DATE: 7/18/2018 BUILDING ADDRESS: 2525 El Camino Real #130 BUILDING OCCUPANCY: A2, Si, Fl, B BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Hourly review Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code I I #N/A 1997 UBC Building Permit Fee V 1997 UBC Plan Check Fee V Type of Review: E Complete Review Structural Only fl Repetitive Fee 1. Repeats * Based on hourly rate E Other Hourly 1.5 Hrs. @ * EsGil Fee $90.00 I $135.001 Comments: Sheet of 1 Carlsbad CBC20 18-0206.rev 7/18/2018 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. PLANS Will the revised sheet A 102.02 replace the currently approved sheet Al 02.01? a) If so, please remove the reference to the wall type G on the partition plan on sheet A 201.02 as the description for wall type G was removed. I see that wall types B and B.l no longer reference 2 layers. However, the pictures of the walls still show 2 layers. Please clearly show which walls will now receive I layer. The description of the revision is very vague. Each sheet of the plans must be signed by the person responsible for their preparation, even if there are no structural changes. California State Law. END OF REVIEW To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: U Yes U No The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Jason Pasiut at Esgil. Thank you. no Print Date: 09/26/2018 Job Address: 2525 El Camino Real, 130 Permit Type: BLDG-Permit Revision Parcel No: 1563022700 Valuation: $ 68,044.13 Occupancy Group: # Dwelling Units: Bedrooms: Project Title: Description: Applicant: JESY ENTERPRISES INC THOMAS KIM 3830 Valley Center Dr, 705-648 SAN DIEGO, CA 92130 619-708-2624 Permit No: PREV2018-0225 Work Class: Commercial Permit Revi5 Status: Closed - Finaled Lot U: Applied: 08/21/2018 Reference U: Issued: 09/11/2018 Construction Type Permit 09/26/2018 Finaled: Bathrooms: Inspector: MColI Orig. Plan Check U: CBC2018-0206 Final Plan Check U: Inspection: Owner: Co-Applicant: R P I CARLSBAD LP UNIVERSAL CONSTRUCTION 1114 Avenue Of The Americas, Floor 45 3830 Valley Center Dr, Ste 705-648 New York, NY 10036-7700 SAN DIEGO, CA 92130 214-660-5232 x215232 858-278-3320 SWEET CLOUD CREAMERY: NITROGEN INSTALLATION FEE AMOUNT BUILDING PERMIT FEE ($2000+) $490.17 BUILDING PLAN CHECK REVISION ADMIN FEE $35.00 FIRE Plan Review Per Hour - Office Hours $132.00 Total Fees: $657.17 Total Payments To Date : $ 657.17 Balance Due: $0.00 Building Division 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov PLAN CHECK REVISION OR Development Services cTCjY of DEFERRED SUBMITTAL Building Division Carlsbad APPLICATION 1635 Faraday Avenue 760-602-2719 B-I 5 www.carlsbadca.gov Original Plan Check Number C C 'O Plan Revision Number O)0 -5 Project Address 9Li5 \ iw.v • \?, b t42..cx3 General Scope of Revision/Deferred Submittal: CONTACT INFORMATION: Name Phone Fax Address OAc 6 L59 Zip Email Address a 0 4V2 - 'k t.LG lrro - O\)%'.S Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1. Elements revised: Lii Plans LI Calculations Soils LII Energy Qther 2. 3. Describe revisions in detail List page(s) where each revision is shown Does this revision, in any way, alter the exterior of the project? Yes V-No Does this revision add ANY new floor area(s)? Yes fZ No Does this revision affect any fire related issu s Yes )No Z riv1()I.E; Is this a complete t? Yes Signature ." rNo Date I i 1635 Faraday Avenue, Carlsbad, CA 92008 Ph: 760-602- 2719 Fax: 760-602-8558 Email: building@carlsbadca.gov www.carlsbadca.gov EsGil A SAFEbuiLf Company DATE: 8/29/2018 DPPLICANT URIS. JURISDICTION: Carlsbad PLAN CHECK #.: CBC2018-0206.rev SET: I PROJECT ADDRESS: 2525 El Camino Real #130 PROJECT NAME: Sweet Cloud Creamery Revision The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. Lii The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. LII The applicant's copy of the check list has been sent to: EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (L' ) Email: Mail Telephone Fax In Person LII REMARKS: By: Jason Pasiut Enclosures: EsGil 8/23/2018 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad CBC2018-0206.rev 8/29/2018 (DO NOTPAY— THIS IS NOTAN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK #.: CBC2018-0206.rev PREPARED BY: Jason Pasiut DATE: 8/29/2018 BUILDING ADDRESS: 2525 El Camino Real #130 BUILDING OCCUPANCY: A-2, S- 1, F- 1, B BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Hourly review Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code I I #N/A 1997 UBC Building Permit Fee iwi 1997 UBC Plan Check Fee [j Type of Review: Repetitive Fee Repeats * Based on hourly rate E Complete Review LII Other LI Hourly EsGil Fee E Structural Only I jHr. @* $90.00 I $90.00I Comments: Sheet 1 of 1 DATE: 21 AUG 2018 JURISDICTION: CARLSBAD PLAN CHECK: CBC2018-0206 PROJECT ADDRESS: 25 El Camino Real #130 PROJECT NAME: Sweet Cloud Creamery Tenant Improvement RECF!VTED AUG 212018 BOLT CITY OF CALS[AD DESIGN BUILDING DIVS ION GROUP PLAN CHECK RESPONSE: 1- Scope of Work for Liquid Nitorgen Work See Cover Sheet DATE: 21 MAY 2018 JURISDICTION: CHULA VISTA BOLT PLAN CHECK: B18-0608 DESIGN PROJECT ADDRESS: 555 BROADWAY, #141 GROUP PROJECT NAME: Sweet Cloud Creamery Tenant Improvement PLAN CHECK RESPONSE: 2 - Plans are signed by State of California Licensed Contractor See All Sheets 3 - Since the occupant load is less than 50, this will not be an A-2 Occupancy. It will be a B occupancy Instead. please revise the plans (Occupancy is updated to B on floor plan - see sheet A100.01) 4 - Since the building is TYPE II Construction, the walls cannot be of wood. Please revise Wall Type F on Sheet Al 02.00 (Fire-Rated documentation has been provided by the manufacturer indicating compliance with______ See A100.O1 See Addendum #1 See A102.O1 9 - Please provide the complete design and detailing of the skylight system , if available ___________________See Addendum #2 10 - Please clarify whether the skylight system wil be glass or plastic. (Skylight to be plastic)