HomeMy WebLinkAbout2525 El Camino Real; 226; CBC2018-0619; Permit(city of Carlsbad Commercial Permit Print Date: 02/01/2019 Permit No: CBC2018-0619 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: 2525 El Camino Real, 226 BLDG-Commercial 1563020900 $0.00 Work Class: Tenant Improvement Lot#: Reference#: Construction Type: Bathrooms: Orig. Plan Check#: Status: Applied: Issued: Permit Finaled: Inspector: Closed -Finaled 11/06/2018 11/06/2018 Plan Check#: Final Inspection: 2/1/2019 11:52:34AM Project Title: Description: RE-OPEN EXPIRED PERMIT CBC2017·0157 · SHELVING FOR BATH & BODYWORKS MANUAL BUILDING PERMIT FEE 5B1473 GREEN BUILDING STATE STANDARDS FEE Total Fees: $27.44 Owner: R P I CARLSBAD LP 1114 Avenue Of The Americas, Floor 45 New York, NY 10036-7700 214-660-5232 x215232 Total Payments To Date: $27.44 Contractor: BOGART CONSTRUCTION INC 9980 Irvine Center Dr, Ste 200 Irvine, CA 92618-4364 949-453-1400 Balance Due: $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov $26.44 $1.00 Commercial Permit Print Date: 06/20/2018 Job Address: (city of Carlsbad Permit No: CBC2017-0157 Permit Type: 2525 El camlno Real, 226 BLDG-Commercial 1563020900 Work Class: Tenant Improvement Status: Closed -Expired 04/04/2017 06/05/2017 Parcel No: Lot#; Valuation: $2,500.00 Reference#; Occupancy Group; Construction Type # Dwelling Units: Bathrooms: Bedrooms: Orig. Plan Check#: Plan Check #; Project Title: Description; BATH & BODY WORKS; INSTALL SHELVING IN 95 SF AREA Applicant: MARY RYAN Po Box 3749 MISSION VIEJO, CA 92690 949-582-3735 FEE BUILDING PERMIT FEE $2000+ BUILDING PLAN CHECK FEE (BLDG) SB1473 BUILDING STANDARDS FEE STRONG MOTION-COMMERCIAL Total Fees: $ 91.58 Owner: R P I CARLSBAD LP 1114 Avenue Of The Americas, Floor 45 New York, NY 10036-7700 214-660-5232 x215232 Total Payments To Date ; $ 91.58 Applied: Issued: Permit Finaled: Inspector: Final Inspection: Contractor: INACTIVE-BOGART CONSTRUCTION INC 9980 Irvine Center Dr, Ste 200 IRVINE, CA 92618-4365 949-453-1400 Balance Due: AMOUNT $52.87 $37.01 $1.00 $0.70 $0.00 Please take NOTICE that approval of your project Includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction," You have 90 days from the date this permit was Issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required Information with the City Manager for processing In accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees /exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. F EXPIRED PERMIT PERMIT HAS EXPIRED IN ACCORDANCE WITH C.B.C. SECTION 106.4.4 ~ AMENDED SY C.M.C.18.04,030 DATEt.,-,\l,,0-1$ SIGNATURE PU-t-4\KJ;, p. Building Division 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov {City of Carlsbad COMMERCIAL BUILDING PERMIT APPLICATION B-2 Plan CheckQ()C2_.Dri(-Ol2clC\ Est. Value PC Deposit --------- Date _.\-'-\-_lo.,,.,_-_\,_,.~.,___ Job Address Z-~2 $"" Suite: 2:Z(, APN: l(6sozo'irl') Tenant Name: __________________ CT/Project#:, __________ Lot#: ___ _ Occupancy:----------,-_.::._· yes/ no D Addition/New: ___________ New SF and Use, ___________ New SF and Use, ____ Deck SF, Patio Cover SF (not including flatwork) D Tenant Improvement: ______ SF, ______ SF, Existing Use _______ Proposed Use ______ _ Existing Use Proposed Use ______ _ □ Pool/Spa: ____ SF Additional Gas or Electrical Features? ____________ _ D Solar: ___ KW, __ Modules, ___ Mounted, Tilt: Yes/ No, RMA: Yes/ No, Panel Upgrade: Yes/ No D Plumbing/Mechanical/Electrical Only: _________________________ _ D Other: __________________________________ _ PROPERTY OWNER Name:-4,~~~-1""'"'-''--'r~~~--,f""r---,,,-..,..--Name: ____________________ _ Address: Address: __________________ _ City: City: __________ State: ___ .Zip: ____ _ Phone: Phone: ____________________ _ Email: f'l,,e, ,r.),,~, __________________ _ DESIGN PROFESSIONAL Name: _________________ _ Address: _________________ _ City: ________ State: ___ ,Zip: ____ City: -,.::.:::,<7~--:-r=✓ Phone: _________________ _ Email: _________________ _ Architect State License: ___________ _ (Sec. 7031.S Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.S by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500)). 1635 Faraday Ave Carlsbad, CA 92008 B-2 Ph: 760-602-2719 Fax: 760-602-8558 Page 1 of 2 Email: Building@carlsbadca.gov Rev. 06/18 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: □ I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. ,/,;,ave and will maintain worker's compensation, as required by Section 3700 of the labor Code, fort □ Certificate of Exemption: I certify that in the performance of the work for which this permit is Issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation Laws f California. WARNING: Failure to secure workers compensation coverage ls unlawful, and shall subject an employer to criminal penalties and civil fines up to $100 0.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. J J✓ CONTRACTOR SIGNATURE: 4--,_.::....::...._..::,,, ____________ ).llAGENT DATE: ;/p,//8 ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: □ I, as owner of the property or my employees with wages as their sole compensation, wlll do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). □ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). □ I am exempt under Section _______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property Improvement. □ Yes □ No 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' llcense number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (Include name/ address/ phone/ contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work): OWNER SIGNATURE: □AGENT DATE: _____ _ --------------------- CONSTRUCTION LENDING AGENCY. IF ANY: 1 hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: ____________________ _ Lender's Address: ____________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future bullding occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D Yes □ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City ofcarlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit Is required for excavations overS'O' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the 8 · ing Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced withl ays from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time :;~~;;:~:c:~:::~~o~:~+ri-d-.Jl'-"-..:a_y,-'(Sl,e,.,,,_::....:\,,-------·n_g_C_od_•_J. __________ DATE: ...J,L·!.,.Jliu.0._,_~/..1./_'h&L--- '/ 1635 Faraday Ave Carlsba B-2 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of 2 Email: Building@carlsbadca.gov Rev. 06/18 PERMIT INSPECTION HISTORY REPORT (CBC2018-0619) Permit Type: Work Class: Status: Scheduled Date BLDG-Commercial Tenant Improvement Closed -Finaled Actual Start Date Inspection Type Application Date: 11/06/2018 Issue Date: 11/06/2018 Expiration Date: 07/31/2019 IVR Number: 15156 Inspection No. Inspection Status 02/01/2019 02/01/2019 BLDG-14 FramefSteel/Bolting/ Welding (Decks) 082889-2019 Passed February 01, 2019 BLDG-Fin al Inspection Checklist Item BLDG-Building Deficiency 082890-2019 Checklist Item BLDG-Building Deficiency BLDG-Structural Final COMMENTS Racking only Passed COMMENTS Racking only Owner: Subdivision: Address: Primary Inspector Michael Collins Mlchael Collins R P I CARLSBAD LP CARLSBAD TCT#76-18 2525 El Camino Real , 226 Carlsbad, CA 92008-1264 Reinspection Passed Yes Passed Yes Yes Complete Complete Complete Page 1 of 1 November 3, 2017 BOGART CONSTRUCTION 9880 Irvine Center Drive, Ste. 200 Irvine, CA 92618 44444 Buena Vista Way Lancaster, CA 93536 (661) 202-4072 Office richard@act1onspecialinspections.com I.C.C. / A.C.I. / A.W.S. Certified • Structural Steel & Welding · Reinforced Concrete • P.T. Concrete • Structural Masonry • Drilled-In Anchors • Epoxy Injection · Fireproofing · Shear Nailing AS! Job# 2711-17 SUBJECT: SATISFACTORY COMPLETION OF WORK REQUIRING SPECIAL INSPECTION PERFORMED UNDER PERMIT NUMBER: BUILDING PERMIT NO.: CBC2017-0IS7 PROJECT NAME & ADDRESS: BATH & BODY WORKS 2525 El Camino Real Carlsbad, CA 92008 This letter is provided to certify Special Inspection Final Compliance for the project referenced above. This certification includes inspection pertaining to: -Wedge Anchor Bolts Based on the observation and inspection performed by Action Special Inspections the above- referenced project has been, to the best of my knowledge, completed in accordance with the approved plans and specifications and the applicable provisions of the California Building Code. Should you have any questions or need further information please do not hesitate to contact this office. -~j:'.L_ ACTION SPECIAL INSPECTIONS Richard McKeehan 0 ClarkDietrich Product Submittal Sheet i-i !_;' i ,! Tech Support: 888-437-3244 Engineenng Services: 877-832-3206 I Sales: 800-543-7140 clarkdietrich corn Product category: Product name: ProSTUD® 20 L TO Drywall Stud 362PDS125-19 65ksl G40EQ • Punched 3-518" ProSTUD 20 LTD (19mi) Coating: G40EQ Color coding: Brown Geometric Properties Web depth 3.625 In Flange width 1.250 in Stiffening lip 0.315 In Design thickness 0.0200 In Yield stress, Fy 65 ksl Weight Punchout width Punchout length Minimum thickness 0.448 lb/ft 1.500 in 2.500 In 0.0190 In Gross Section Properties of Full Section, Strong Axis Cross sectional area (A) 0.132 in' Moment of inertia (Ix) 0.266 in' Radius of gyration (Rx) 1.420 In Gross moment of inertia (ly) 0.027 In' Gross radius of gyration (Ry) 0.454 in Effective Section Properties, Strong Axis Effective area (Ae) Moment of inertia for deflection (lxe) Section modulus (Sxe) Allowable bending moment (Ma) AlloWable shear force in web (Unpunched) (Vag) Allowable shear force in web (Punched) (Vane!) Torsional Properties St. Venant torsion constant (J x 1000) Warping constant (Cw) Distance from shear center to neutral axis (Xo) Radii of gyration (Ro) Torsional flexural constant (Beta) Unbraced Length (Lu) Notes= 0.048 in' 0.254 ln' 0.080 In' 3,1031n~bs 2031b 189 lb 0.0176 in' 0.072 in' -0.876 in 1.729in 0.743 22.1 in 09.22.16 (Non-Structural Metal Framing) • Embossments in web are oliy placed on sections 2-112" and wtder. ASTM & Code Standards: • AISI S!00-12 & S220-15 • Meets or exceeds ASTM C845 & C754 • ASTM E119, E72 & E90 • lntertek CCRR-0207, LA RR 26019 • ProSTUD compiles with the SFIA Code Compliance Certiftcatlon Program • MulUple UL® Design Listing Including: V438, V450 & U419 • SOS & Product Certification Information available at www.clarkdietrich.com • U.S. Patent No. 9,010,070 • Calculated properties are based on AIS1 S100-12, North American Specilieation for Design of CokHotmed Steel Structural Membe.r$ end AISI S220--15. North American Standard for ~ooned Steel Fl'amlng • Nonstructu,.I Membera. • Effec:tive propeftiea Incorporate the !ilf11ngth increaH from tt,e cold work of fotmlng as applicable per AISI A7.Z. • Tabulated gross properties, incfudlng tol'$lonal ~rtles, are based on full-unreduced cross section of the Sluds, away from ponchouts. • For def\ection calc\ltauons, use lhe effective moment of inertia. • AUow•ble rfl0m4lr'lt lncludn cold work of forming. • Allowable moment Is taken aa the IOWesl value based on local or dlstortlonal buckling. Di&tortlonal bucking strength is based on a k..phl • o. • East Coast Punch Pattern: Ceni.r or knOckouts are 12" from lhe leeiding .dge then ,48" o.c. • West Coast Punch Panem: Center of knockouts are 24" from the leading edge !hen 24· o.c. Sustainability Credits: For more details and LEED letters contact Technical Services at 888-437-3244 or "ls.It www.clarkdietrlch.com/LEEO LEED v.t MR Cntdll-Bullding Product Disclosure and Optimization: EPO {1 point)· Sourcing of Raw Materials (1 point) -Material Ingredients (1 point) -Construction and Oemo&IUon Waste Management (up to 2 points) -\nnovatlon Credit (up to 2 points). LEED 2009 Cr.dit MR 2 & MR,_ Clark.Dietrich's steel products are 100% recydable and have a minimum recycled content or 34.2% (19.8% posl-consumer and 14.4% pre.conS1,1tJ111r). If seeking a higher numbor to meet Credit MR 5, please contact us al (info@ctarkdtetrteh.com 1888-437-3244) I ProJ•ct Inf~;;;;.;,:; · ---·· ·-- Name: Address: Contractor tnformatlon Name: COolad Phone. Fex· Architect Information Name· CootaCl: 7 ::."· I CD.PDS O 07118 ClatkD1etllCh Buddirtg Systems ··--·---· ---· -------· ~~ECLIPSE ENGINEERING Clarification Item #1 Date: Project Number: Project: To: From: C/C: November 21, 2017 17-03-229 Bath & Body Works -PO 25418 Carlsbad, CA Sara Sisk & Jonnie Porter PIPP Mobile Storage Systems, Inc. 2966 Wilson Drive NW Walker, Ml 49544 Nick Burnam, PE FILE ECLIPSE-ENGINEERING.COM Re: Clarifications to the Calculations and Detail Sheet 1 1) The contractor on site noted that the concrete floor is an elevated structural slab over concrete and steel beams that ranges from 3 ½" thick at the storefront to 6" thick at the rear of the store, where the stockroom is located. 2) We updated the calculations that verify the capacity of the anchors for the ¾"lj, HILTI KB-TZ anchors with the longer embedment that were used at this location. This verifies that the anchors in the ITAT (anti-tip) track are adequate when be spaced at the normal 22½" o.c .. Please call with any specific questions. Attachment: Updates to calculations page 10 and Detail Sheet 1 MISSOULA (Ol UMBIA FAl. lS SPOKANE B1;:ND PORT! P.ND ll3WdMari,beB,_,.MTSl!ll2 721lltdeu5N&,&ieD,QuaFlls,IIITlil'312 GWtslRJrileMB.,UIWSpilrle, WAllll:201 Plme:(O) mW• Fax:(G)~768 Pim: (G)alWUi • Fa: 14116) 562-\768 Am:(91)1121•1'731 • Fat(U)562-4768 ffiSWEUC..,Me8,BelXl,OR 871112 lllSNClinmShel,&lle118)Pakm,Cfl:9T201 Am: ~3!1«a •Fu (408) ~788 f'IQIB: (lil3)l6-1229 • Fa:(408) 55M768 ~AB ~~ECLIPSE ECLIPSE-ENGINEERING.COM ENGINEERING Structural Calculations Steel Storage Racks By Pipp Mobile Storage Systems, Inc. PIPP PO #25416 SO #62396 Bath & Body Works #305 The Shoppes at Carlsbad 2525 El Camino Real -Space #226 Carlsbad, California 92008 Prepared for: Pipp Mobile Storage Systems, Inc. 2966 Wilson Drive NW Walker, Ml 49544 OlgltallV $1gned ........ S. BtJrna,allllC-- Contact lnfcc 376 S~r., Suite 8, Bend, OR 977 9-9659 Date: 2017.11.21 :16-08'00' Please note: The calculations contained within justify the seismic resistance of the shelving racks, the fixed and mobile base supports, and the connection to the existing partition walls for both lateral and overturning forces as required by the 2016 California Building Code. These storage racks are not accessible to the general public. MIS50UL/\ l13 west Mail. 516! B, MmolJa, MT 598112 PhOlle: (406) 721-5733 • Fax: (406) 721-4988 COLUMBIA f 1\! I !:l SPOi:t.NE 728NudeusAve.SlieO, Qunbiafals,MT 58lll2 421 We51Rlver&ideAve., Slie.1121 Spokane. WAllll201 Phone: (408) 89U301 • Fax: 40&e92-2361! Phooe: (5Clll) 921-7731 • Fae (9)9) 821-670II BEND 376SNEUDdwl,Slie8,Bend, OR 87702 Pmne: {SU) 388-8658 • Fae (Ml) 31U708 ( eECLIPSE E NGI NE ERIN G BATH 6 BODY WORKS #305 CARLSBAD.CA 11/21/2017 Rolf Armstrong, PE Pipp Mobile STEEL STORAGE RACK DESIGN 2015 IBC & 2016 CBC -2208 & ASCE 7-10 -13.3.1 & 15.5.3.4 Design Vertical Steel Posts at Each Corner -Shelving Dimensions: Are Shelving Units set as Si~le Depth (1) or Back to Back (2)? Nu := 1 Tdal Hei(1lt of Shelving unit- Width of Shelving Unit - Depti of Shelving unit- Nuni>er of Shelves - Vertical Shelf Spacing - h1:= 10.00-ft w:= 4.00-ft d:= Nu-(2.50-tt) = 2.5ft N:= 6 S := 24.00-in plf:= lb-ft-l psf := lb· ft-2 pcf := lb• ft-3 kips := 1000-lb ks. ki . -2 I:= PS·ln Shelving Loads -Maximum Live Load on each shelf is 100 lbs: Weight per shelf - Load il psf- Design Live Load on Shelf - Dead Load on Shef- wtj LLr= -= 10-psf w-d LL:= Lli = 10-psf DL := 2.50-psf Section Properties of Double Rivet 14 Gauge Steel 'L' Post: Modulus of Elasticfy of Steel - Physical Dimensions of L Post : L Post Width -out-i>-out - Radius at Corners - L Post Width -End -to -IF - b1c := b1 -t = 1.425-in Radius of Gyration in x and y - Section Modulus in x and y- Mommt of Inertia in x and y- Ful 6 Reduced Cross Sectional Area's - Length of Unbraced Post - Effective Length Factor - Weight of Post - WP := psteel• Ap,· h, = 7.66 lb Tdal Vertical Load on Post - Steel Yield Stress - psteel := 490-pcf Fy:= 33-ksi E : = 29000-ksi Density of Steel - b1 := 1.500-in Re:= 0.188-in L Post Depth -out-to-out - Post Ttickness (14 Gauge) - d1 := 1.500-in t := 0.0750-in L Post Depth -End -kl -IF - d1c := dI -t = 1.425-in ry:= 0.5390-in Sy := 0.0396-in3 ly:= 0.0406-in4 Apr:= 0.138-in2 rx := 0.5390-in Sx := 0.0396-in3 Ix := 0.0406-in4 Ap1 := 0.225-in2 Lx := S = 24.00-in Kx:= 1.7 Ly := S = 24.00-in Ky:= 1.7 Li:= S = 24.00-in Kt := 1.7 Vertical DL on Post- DL-w-d-N Pd := ---+ Wp = 45.16Ib 4•Nu Vertical LL on Post - PI:= LL·W·d•N = 150Ib 4•Nu fE(LIPSE ENGINEERING BATH 6 BODY WORKS #305 CARLSBAD, CA 11/2112017 Rolf Armstrong, PE Floor Load Cak:ulations : Weight of M>bile Carriage: We:= 40-lb Tdal Load on Each Urit: W:= Nu•4•Pp +We = 820.63Ib Area of Each Shel Untt: A..i := w-(d + 6-in)= 12tt2 Floor Load under Shel: w PSF := -= 68-psf Au NOTE: SHELVING LIVE LOAD IS CONSISTENT WITH 75 psf REQ'D FOR RETAIL FLOOR LOADING Rnd the Seismic Load using Full Design Live Load -ASCE-7 Seismic Design Procedure: Building"s Risk Category - Demrmine Ss and S1 from maps - Demrmine the Site a ass - Demrmine F8 and Fv - Demrmine Sos and S01• Seisrric Deisgn Camgory- BRC:= 2 S6 := 1.113 SSC := "D" Fa = 1.055 2 Sos== -·(F1-s1) = 0.783 3 Importance FacDr - S1:z: 0.428 Fv = 1.572 2 Soi:= --(Fv•Si) = 0.449 3 SOC= "D" StructlJ'al System -Section ASCE-7 Sections 13.3.16 15.5.3.4.: 4. Steel Storage Racks Tdal Vertical DL Load oo Shelf- R:= 4.0 Rp := R no := 2 ap := 2.5 Tdal Vertical LL Load <11 Shelf- Cd := 3.5 Ip := 1.0 w,:= LL-w-d = 1001b Seisrric Analysis Procedure per ASCE-7 Sections 13.3.1615.5.3.4: Average Roof Height- Seisnic Base Shear Factor- Shear Factor Boundaries- Seisrric Coefficient - Overstrengh Factor - Height of Rack Attachment -(0-0" For z := 16•5• ft Ground floor) 0 4-a • Sos ( z \ • P • 1 + 2--'= 0.391 ~ h,) Ip V1min := 0.3· Sos· Ip = 0.235 V1:= min(max(vtmin, v1), vbnax) = 0.391 0:= 2.0 NOTE: By ASCE 7-10 Section 13.3.1, n does not apply for vertically cantilevered arclitectural systems. 2 ( ~~ECLIPSE ENGI NE ERI NG BATH 6 BODY WORKS #305 CARLSBAD,CA 11/21/2017 Rolf Armstrong, PE Seismic Loads Continued : ASD ~ Fa ASD, Shear may be red11:ed- Seismc DL B~e Shear - DL Force per Shelf : Seismc LL Base Shear- LL Force per Shel : Vp := 0.7-V1 = 0.274 Vtd := Vp-Wd•N = 49.48Ib Fd := Vp• Wd = 8.25Ib Vu := Vp•WrN = 164.36Ib F1 := Vp •W1 = 27.39Ib VP<l> := V1 = 0.391 Vtd<l> := VP<l>-Wd •N = 70.68Ib Fd<l> := VP<l>,Wd = 11.78Ib vtl<l> := VwWrN = 234.Slb F1q, := VP<l>•W1 = 39.13Ib F1.s14>:= 0.67,VP<l>•Wi = 26.22Ib 0.67 • LL Force per Shelf : F1.s1 := 0.67•Vp•W1 = 18.35Ib Force Distribution per ASCE-7 Section 15.5.3.3: Operaing Weight is one ofTwo Loading Conditions -Condition #1: Each Shelf Loaded to 67% of Live Weight: Currulative Heights of Shelves - H1 := 0.0· S + 1.0• S + 2.0· S + 3.0-S + 4.0-S + 5.0· S Taal Moment at Shelf Base - Taal Base Shear - Vertical Disribution Factors for Each Sheff - wd. o.o. s + Wr 0.67• o.o. s C1 := --------= 0.000 Mt F1 := C1•(V1) = 0.00 F14> := C1•(V1<1>) = 0.00 Wd· 2.0· S + Wr 0.67• 2.0· S C3 := --------= 0.133 Mt F3 := cdv1) = 21.28Ib F3<l> := cd v1<1>) = 30.40Ib wd. 4.0· s + Wr 0.67-4.0· s C5 := --------= 0.267 Mt F5 := cdv1) = 42.56Ib F64> := c5-(v1<1>) = 60.SOlb H := H1 + H2 = 30.00ft M1:= H-Wd + H-0.67•W1 = 2913.12ft-lb V14> := Vtd<l> + 0.67• V114> = 228.00lb Wd· 1.0· S + Wr 0.67• 1.0• S C2 := --------= 0.067 M1 F2 := c2'(v1) = 10.64Ib F24> := C2•(V14>) = 15.20Ib Wd· 3.0· S + Wr 0.67-3.0· S C4 := --------= 0.200 Mt F4:= C4-(V1) = 31.92Ib F4q, := C4•(V1<1>) = 45.60Ib Wd• 5.0· S + Wr 0.67• 5.0· S Cs :=--------= 0.333 Mt F6 := C6-(V1) = 53.20Ib F6<l> := C6-(V1<l>) = 76.00lb Coefficients Should total 1.0 3 eECLIPSE ENGI N EER I NG BATH 6 BODY WORKS #305 CARLSBAD,CA 11/21/2017 Rolf Armstrong, PE Force Distribution Continued : Condtion #2: Top Shel Only Loaded to 100% of Live Weight Tcxal Moment at Base of Shelf-M1a := H-Wd + (N -1).s.w, = 1903ft-lb T cxal Base Shear - Wd•0.0-S + 0-Wr0.0-S C1a := -------= 0 M1a wd. 1.0-s + 0-Wr 1.0-s C2a := -------= 0.032 M1a F1a := C1a•{V2) = 0 .!.I Coefficients Should total 1.0 Condition #1 Controls for Total Base Shear By Inspection, Force Distribution for intermediate shelves withmi LL are neg~gible. Moment calculation for each column is based on mtal seismic base shear. Column at center cl rack is the worst case for this shelving rack system Column Design in Short Direction : Allowable Bending Stress -Fb := 0.6· Fy = 19.8-ksi Ratio of Allowable / Ultimate Stress - Bending Stress on Column- Bending al tie Base of Each Column is Adequate MUST BE LESS THAN 1.0 4 ( ~~ECLIPSE ENGI NE ERING BATH 6 BODY WORKS #305 CARLSBAD, CA llJ2112017 Rolf Armstrong, PE !l Deflection of Shelving Bays -worst case is at the bottom bay-the following is tie list of shears used in deflection equaions. V1::,.1 := V1 -F1 = 160Ib V1::,.3 := V1::,.2 -F3 = 128Ib s -=614.77 A1 1 max{V1::,.2, V1::,.28)-s3 A2 := ------'------'--= 0.036· in Nu•4 12-E·lx Aa := 0.05· ht= 6-in At:= A1 + A2 + D.3 + A4 + A 6 + A 6 = 0.1431-in it( At < Aa, "Deflection is Adequate" , "No Good" = "Deflection is Adequate" Noil: The deflection shall not exceed 5%Hi, so shelving deflection is adequate. Moment at Rivet Connection: Shearon each rivet - Ms Vr := --= 319.2Ib 1.5-in 2 dr · 7i 2 Ar := --= 0.0491-in 4 Steel Stress on Rivet- dr := 0.25-in Vr fv := -= 6.5-ksi Ultimate Stress a, Rivet . (SAE C1006 Steel)-Fur:= 47.9ksi Omega Fack>r ,.... . _ 2 0 Ar (ASD)-ur ,-· ANowable Stress 0.4• Fur Rato of Allowable/ fv on Rivet_ Fvr := --= 9.58· ksi Ultimate Stress _ -= 0.68 MUST BE LESS THAN 1.0 Or Fw ..._;.,__ __ RIVET CONNECTION IS ADEQUATE FOR MOMENT CONNECTION FROM BEAM TO POST Seismic Uplift on Shelves : Seisnic Vertical COl!llOnent: Ev:= 0.2·Sos·(DL + LL)·W·d = 19.57Ib Vertical Dead Load ci Shelt D := ( DL + LL)· w-d = 125.00 lb Noil: since the shel LL is used to generate the seismic uplift force, ~ may also be used to calculate the net uplift load For an el!llty shelf, roly the DL would be used, but the ratio of seisnic upfift will be the same. NetUplift Load on Shel: Fu = -55.43 lb Note: This uplift load is for the full shelf. Each shelf ~II be connected at e.K:h comer. Number of Shelf Uplift Force Fu Ne:= 4 per Comer·. Fuc := -Connections: Ne Fue = -13.86 lb HoTE: Since the uplift face is negative, a mechanical connectioo is not required I 5 fECLIPSE ENG I NEE RING BATH 6 BODY WORKS #306 CARLSBAD,CA Find Allowable Axial Load for Column : Allowable B11:kling Sresses - Distance from Shear Center to CL of Web via X-axis Distance From CL Web to Cenroid- Distance From Shear Ceni!r to Centroid - Polar Radius of Gyration- Torsion Constant - Warjing Constant- Shear Modulus - Elastic Flexural Buckling Stress - Allowable Compressive Stress - Fck:tor of Safety for Axial Comp. - ec:=--- 4-lx Xe := 0.649-in -0.5-t Xo :=Xe + ec ✓ 2 2 2 ro := rx + ry + Xo 1 ( 3 3) J:= -. 2-brt + drt 3 11/21/2017 Rolf Armstrong, PE <Tex= 49.95-ksi ec = 1.9043-in Xe = 0.6115-in Xo = 2.5158-in r O = 2.6287-in J = 0.00063-in 4 Cw = 0.0339-in6 G := 11300-ksi cr1 = 13.611-ksi r3 = 0.0841 F81 = 10.8522-ksi F8 = 10.8522-ksi Fn = 10.8522· ksi no := 1.92 6 ( 'eE(LIPSE ENG I NEER ING Find Effective Area - Deilrmine the Effective Width of Fla,ge - Flat width of Flange - Flange Plate Buckling Coefficient - Flange Slenderness Factor- Effective Flange Width - Deilrmine Effective Widti of Web: Flat width of Web - Web Plate Bucklilg Coefficient - Web Slenderness Factor - Effective Web Widti - Effective Column Area - Noninal Column Capacity - AlloWdble Column Cap.-:ity- Check Combined Stresses - Magnificciion Factor - Combined Stress: BATH 6 BODY WORKS #305 CARLSBAD.CA w,:= b1 -0.5-t ~-1;,2:,R p,:= (1-0.22 \_!_ >.., ) >.., b8 := if{>..i > 0.673, p,-w1, w1) 2 n · E· Ix Pcrx := -- { Kx· Lx)2 Per := Pcrx w1 = 1.4625-in I<,:= 0.43 >-i = 0.6052 Pf = 1.0517 be = 1.4625-in Ww = 1.425-in >-w= 0.5897 Pw = 1.0632 he = 1.425-in 11/21/2017 Rolf Armstrong, PE Ae = 0.2166-in2 Pn = 23501b Pa = 12241b Pcnc = 6980.77 1b Per = 6980.771b MUST BE LESS THAN 1.0 Final Design: 14 GA. 'L' POSTS ARE ADEQUATE FOR REQD COMBINED AXIAL AND BENDING LOADS NOTE: PP is the total vertical load on post, not 67% live load, so the design is conservative 7 eECLIPSE ENGINEERING BATH 6 BODY WORKS #305 CARLSBAD.CA 11)21)2017 Rolf Armstrong, PE STEEL STORAGE RACK DESIGN -cont'd Find Overturning Forces : T~al Hei~t of SheMng Unit- Deplh of SheMng Unit- Nurmer of Shelves - He~ht kl Top Shelf Center of G - h1 = 10ft d = 2.5ft N=6 htop := ht = 10ft Width of SheMng Un~ - WORST CASE Vertical Shelf Spacing - He~ht kl Shelf Center ofG - w = 4ft S = 24-in he:= (N + l) · S = 7ft 2 From Vertical Distribution of Seismic Force previously calculated -Controlh~ Load Cases: ASD Moments -Mb : = O LRFD Maq, := F1q,·O.O·S + Fw 1.0-S + F:w2.0-S + Fw3.0-S + F6cl>•4.0-S + F64>•5.0-S Moments -M1>q, := O For scraws-ASD Weight of Rack and 67% d LL - For Anchors-LRFD W1 := N-( 0.6 -0.14-Sos)•(Wd + 0.67-w,) = 285.741b W1q, := N-( 0.9 -0.2·Sos)·(Wd + 0.67-w,) = 433.161b Overturning Rack and 67% of LL - Seisnic Rack and 67% of LL Tension 6 Shear - M1 := Ma + Mb = 1170.40ft-lb Weight of Rack and 100% Top SheW - W2 := ( 0.6 -0.14-Sos)·(Wd· N + w,) = 137.631b Overturning Rack and 100% Top Shelf - Seisnic Rack and 100% of LL Tension 6 Shear - M2 := V1d· he+ Fr htop = 620.28ft-lb Face on Column Screws 6 Anchors: ( V1 V2 \ Tension Single -Tsmax := max 4 , 4 , 0-lb) = 39.901b Shear Sin~e -Vsmax := max(T 1, T2, 0-lb) = 162.651b Tension Double- Shear Double - Tdmax:= 2• Tsmax = 79.801b Vdmax := 2•Vsmax = 325.291b M1q, := Maq, + Mb<l> = 1671.99ft-lb 1 ( M2q, W2q, \ T2q,:=i -d--l)=125.071b V2q, = 109.821b Tsmaxq,:= max(T1q,, T2q,, 0-lb) = 226.lllb ( Vlq, V2q, \ Vsmaxq, := max 4 , 4 ) = 57.00 lb Tdmaxq,:= 2·Tsmaxq, = 4521b Vdmaxq, := 2· Vsmaxq, = 114 lb 8 ( ~iECLIPSE ENG I NE ERING BATHS BODY WORKS #305 CARLSBAD,CA 1112112017 Rolf Armstrong, PE STEEL BASE CLIP ANGLE DESIGN -A1018 PLATE STEEL Tension (Uplift) Force at Corner. Ttickness of Angle: Width of Angle Leg: Distance out to Tension Force: Design Moment on Angle: Allowable Bending Stress: Ultimate Tensile Strength of aip: Effective Net Area of the aip: T := 50-lb Yield Stess of Angle Steel: la := 0.075-in 14 ga Foot Plate b8 := 1.25· in Length of Angle Section: L:= 0.75-in Section Modulus of Angle Leg: M := T• L = 3.125ft• lb Bending Stress on Angle: Fb := 0.90· Fyp = 32.4· ksi Raio of Aflowable Loads: Fup := 65· ksi Gross Area of the aip: Aee := Age -[ta•(0.375-inTI = 0.0656· in2 Fyp := 36-ksi La := 1.375• in 2 ba•ta 3 Se := --= 0.0012-in 6 fb := ~ = 32-ksi Se fb -=0.988 MUST BE LESS THAN 1.00 Fb Age:= ba·ta = 0.0938-in2 Limiting Tensile Strength ofCip: Temaxcj, := min[( 0.90· Fyp·Agc}, ( 0.75• Fup' Aee}] = 3037.5Ib ii(r cmaxc1> > T smaxcj,, "Checks Okay" , "No Good" = "Checks Okay" - 14 GA. ANGLE CLIP WILL DEFORM PRIOR TO ANCHOR PULLING OUT OF CONCRETE, BUT NOT WILL NOT TEAR COMPLETELY THROUGH, THEREFORE CLIPS ARE ADEQUATE. BEARING STRENGTH OF SCREW CONNECTIONS -AISI E.4.3.1 Omega for Bearing(ASD)-0 5 := 3.00 Speciied Tensile Stress of Clip S Poot , Respectively -F ui: = 5 lksi Diameter of Screw - 14 GA Clip Thickness - 14 GA Post Ttickness - Nomnal BearingStrength- Single Screw -ASD dss := 0.25in '51 := 0.075in '52 := 0.075in (AISI C-E4.3-3) P05:= min 2.7•Fui·dss·lsi 11 = 2200 1b [[ 4.2·Fu2.J dss·ls23 \\ Allowable Bearing Strength - 2.7•Fu2·dss·ls2 )) Pns Pas := -= 733.3Ib Os nu:= 2.35 Fu2:= Slksi Double Screw • ASD Pnd Pad:= -= 1466.5Ib Os 9 ~iE(LIPSE ENG I NEE RING BATHS BODY WORKS #305 CARLSBAD,CA lll2ll2017 Rolf Armstrong, PE SCREW CONNECTION CAPACITIES (1/4"<1> SCREW IN 14 GA STEEL): Allowable Tensions, Pullout - Allowable Tensions, Pullover - Allowable Shear - Noe: Values ootained from 'Scafco' labels using an O = 3.00 Single Screw -ASD T sst := 227Ib T SSV : = 656Ib V55 := 600Ib Double Screw -ASD Tsdt := 2• T sst = 454Ib Tsdv := 2· Tssv = 1312Ib The allowatfo shear values for (1) lJ/f' dia. screw exceeds the allowable bearing strength of the connection. TherEiore, bearing strmgth governs br screw comecfon capacity. Ref Attached 'Scafco' Table forV 6 T Values BOLT CONNECTION CAPACITIES (3/8" DIA. x 3", MIN., HILT! KB-TZ WITH 2" EMBEDMENT): Allowable Tension Force- Allowable Shear Force - Single Anchor -LRFD T as := 1107-lb Double Anchor -LRFD Tad:= 2149-lb Ref Attached 'HIL Tl' PROFIS calcs for VS T Values Vas := 1466-lb Vad := 2055• lb DETERMINEALLOWABLE TENSION/SHEAR FORCES FOR CONNECTION: Allowable Tension Force - Allowable Shear Force - Single Screw -ASD Tas1:= Tssv = 656Ib Vasi:= min(Vss, Pas)= 600Ib Double Screw -ASD Tas2:= Tsdv = 1312Ib USE: HILTI KB-TZ ANCHOR (or equivalent) -3/8" x 3", min., long anchor with 2" embedment installed per the requirements of Hilti to fasten fixed shelving units to existing concerete slab. Use J./4" dia. screw to fasten base to 14 GA shelf member. 5 C:= - 3 Combined Loading c-· 1< + (v.,... l' =0.08 Wall Supported !l•Vsmaxcj> <1.00 Shear Loading = 0.08 (Single Anchor)-T as ) Vas ) OKAY (Single Anchor)-Vas n (v T 1 Tmsion Pullout T Combined Loading u · ~ + 0.71-~ = 0.22 <1.00 ~=0.18 (Single Screw) -1.10· !15 Vasi Tasl ) OKAY (Single Screw) -Tsst c·-''+ (··-" =0.08 Wall Supported {l Vdmaxcl> Combined Loading <1.00 Shear Loading = 0.11 (Double Anchor) -Tad ) Vad ) OKAY (Double Anchor)-Vad Combined Loading nu {Vdmax + 0.71• Tdmax l = 0.22 <1.00 Tmsion Pullout Tdmax = 0.18 (Double Screw)-1.10·0s Vas2 Tas2 ) OKAY (Double Screw)-Tsdt < 1.00 OKAY <1.00 OKAY <1.00 OKAY <1.00 OKAY 10 ( ~~E(.LIPSE ENGI NE ERING BATH 6 BODY WORKS #305 CARLSBAD,CA 11/21/2017 Rolf Armstrong, PE STEEL ANTI-TIP CLIP AND ANTI-TIP TRACK DESIGN Tension (UplifO Force on each side -T := 2-Vdmax = 650.58Ib Connection from Shelt to Carriage = 1/4" diameEr bolt through 14 ga. steel: Cap~ity of 1/4" diam. screw in 14 ga. steel --------Zc := 715-lb ~T < 2-Zc, "(2) 1/4" Bolts are Adequate", "No Good" = "(2) 1/4" Bolts are Adequate" Use 3/113" Diameter anti-tip device for connection of carriage to track Yield Sress of Angle Steel - Fy:= 36-ksi Tlickness of Anti-tip Head - 13 := 0.090-in Width of Anti-tip Rod + Radius - br := 0.25-in Width of Anti-ip Head - ba := 0.490-in 2 Area of Anti- tip Weld- Stress on Weld Connection- Aw := 1r-br"(0.094-in)-cos(45-deg) = 0.052-in2 fw := _!_ = 12.4623-ksi Aw Area of Anti- tip Rod- Stress on rod- 7f· br 2 A;r:= --= 0.049-in 4 fr := _!_ = 13.2535-ksi Ar Ratos of fw to Fy 6fr to Fy: fw -= 0.3462 Fy fr -= 0.3682 Fy Width of Anti-tip Fla,ge - Bending Moment on Leg- Bending Stress on Leg - Width of Anti-np track - Spacirg of Bolts- Design Moment on Track - for continuous track section AUowable Stress of Aluminum - 0.85•ba -br La:=----= 0.083-in 2 L:= 5.1-in Sui := 22.5· in T-Stti M:=-- 8 ( ) = 0.5934 0.3· 70-ksi The stess on the b~t head is less than the weld and material capacity. Tension Force per Flange leg- Sectioo Modulus of Leg - Raio of Allowable Loads - Tlickness of Alumilum Track (average thickness) - Sectioo Modulus of Track- Bending Stress on Track- Rafo of Allowable Loads - 2 ba• ta 3 S1 := --= 0.001· in 6 fb --=0.67 0.85-Fy ,___ __ MUST BE <1.0 ~:= 0.33-in 2 L-11 3 Si := -= 0.093-in 6 fba := M = 19.767-ksi s, fba -= 0.94 Fb Ratio of Allowable Loads (Sirgle Anchor) - for continuous track section 2-Tdmaxcj, __ ...;.=0.82 las ANTI-TIP CLIP STEEL CONNECTION AND TRACK ARE ADEQUATE 11 ~~ECLIPSE ENGINEE RIN G Connection from Steel Racks to Wall BATH 6 BODY WORKS #305 CARLSBAD,CA Seismic Analysis Procedure per ASCE-7 Section 13.3.1: Average Roof Height- Height of Rack Attachments - (AtTop klr fixed racks coonected to walls) Seismic Base Shear Factor- 21> = 26.5ft v, = 0.51 ShearFactorBoundanes- Seismic Coefficient - V1min := 0.3· Sos· Ip = 0.235 V1max : = 1.6-Sos· Ip = 1.252 Nurmer of Shelves - Tdal Weight oo Rack- N=6 Seismic Face at top and bottom - Connection at Top: Standard Stud Spacing-Sstud := 16-in Nurmer of Connection Points on each rack - Ne:= max[2, (floor(~']~ = 3 Sstud) LJ Capa::ity per inch of embedment into wood Nailer- Fa Steel Studs: Pullout Capacity for #10 Screw in 20 ga studs (per Scafco) - Connection at Bottom: T20 := 84-lb V1:= min(max(Vtmin, V1), V1max) = 0.51 Weight per Shelf-Wtj = 1001b Wr: = 4-(Pd + 0.67•P1) 0.7-VrWr Ty:=---2 Width of Rack - Wr = 582.63 lb Ty= 103.981b w = 4ft Face on each connection point - Ty Fe := -= 34.661b Ne Reql.ired Embedment Depth - Ratio of Allowable Loads for screws into walls - Fe . d1 := -= 0.257-m Ws Fe -=0.41 T20 Ratio of Allowable Loads for anchors into slab - f!•Ty --=0.14 0.7-Vad MUST BE <1.0 MIN #10 SCREW ATTACHED TO EXISTING WALL STUD IS ADEQUATE TO RESIST SEISMIC FORCES ON SHELVING UNITS. EXPANSION BOLT IS ADEQUATE AT THE BASE. 11/21/2017 Rolf Armstrong, PE MUST BE <1.0 12 ( lllJSGS Design Maps Summary Report User-Specified Input Report Title 17-03-229 Wed March 22, 2017 18:00:25 UTC Building Code Reference Document 2012/2015 International Building Code {which utilizes USGS hazard data available in 2008) Site Coordinates 33.17832°N, 117.33234°W Site Soil Classification Site Class D -"Stiff Soil" Risk Category I/II/III )SGS-Provided Output S5 = 1.113 g S1 = 0.428 g SMs= 1.174g SMl = 0.673 g S05 = 0.783 g S01 = 0.449 g For information on how the 55 and 51 values above have been calculated from probabilistic (risk-targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" bullding code reference document. o, ..... () 111 1.20 1.0!! Q9(. a.a• Q/2 o.w Q'6 0.2t 0.12 MCfRResponH Spectrum 0.00 --------------+--+--+--< <lCl:I Cl:bl 040 O.W CIIOJ 1.CJJ I.~ I '-:I l(;l IIIJ ZOl P4<fo~ T (u~) ~ () ,~ 0!111 Des,g, Response Spectrum O.al 0 /2 Q<,o 0,., OCll 0"" 0 li Q :,~ 0 Iv 00!1 000 -t--1>---1---t--t---t--1---t--t--+-~ Q~ u~ 0~ 0~ Cl~ 100 1ro ·~ I~ I~ i~ f'<!!(I~ J (g~~) though this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject-matter knowledge. Designation hlckness {mil) 18 27 020 30EQO 30 33EQS 33 43EQS 43 54 68 97 118 127 Table Notes 0.0179 0.0188 0.0269 0.0283 0.0179 0.0188 0.0223 0.0235 0.0296 0.0312 0.0280 0.0295 0.0329 0.0346 0.0380 0.0400 0.0428 0.0451 0.0538 0.0566 0.0677 0.0713 0.0966 0.1017 0.1180 0.1242 0.1270 0.1337 0.0843 25 0.0796 22 0.0844 20-0rywall 0.0820 20-0rywall 0.0781 20-0rywall 0.0790 20-Structural 0.0764 20 -Structural 0.0712 18 0.0712 18 0.0849 16 0.1069 14 0.1525 12 0.1863 10 -SSMA 0.2005 10-SCAFCO 1 Minimum thickness represents 95 percent of the design thickness and Is the minimum Mceptable thickness delivered to the Jobslte based on Section A2.4 of AJSJ S100-07. i The tables In this catalog are calculated based on Inside corner radii listed In this table. The Inside corner radius Is the maximum of '/u -t/2 or 1.St, truncated after the fourth decimal place (t • design thickness). Centerline bend radius Is calculated by adding half of the design thickness to listed corner radius. Screw Capacities General Product Information I 1 ·11 43 0.0451 33 864 544 54 0.0566 50 65 1188 1566 985 1202 68 0.0713 50 65 1562 1972 1241 1514 97 0.1017 50 65 1269 1269 118 0.1242 50 65 1550 1550 -· . 127 0.1337 50 65 1668 1668 . Table Notes 1. C21pacltles based on AISI 5100·07 Section E2.4 for fillet welds and E2.S for flare groove welds. 2. When connecting materials of different steel thicknesses or tenslle strengths, use the values that correspond to the thinner or lower yield material. 3. Capacities are based on Allowable Strength Design (ASO) and Include appropriate safety factors. 4. Weld capacities are based on either '/,2• or YI" diameter E60 or E70 electrodes. For thinner materlals, 0.030" to 0.035" diameter wire electrodes may provide best results. s. Parallel capacity Is considered to be loading In the direction of the length of the weld. 6. For welds greater than 1 ", equations E2.4-1 and E2.4-2 must be checked. 7. For flare groove welds, the effective throat of weld Is conservatlve:ly assumed to be less than 2t. 8. *Flare grove weld capacity for material thicker than 0.10" requires engineering Judgement to determine leg of welds (W1 and W1). Allowable Screw Connection Capacity (lbs per screw) Thickness Fy Yield mil)' (ksi) 111 50 020 57 65 87 48 95 57 30EQO 57 65 122 60 133 71 30 33 45 129 55 141 65 33EQS 57 65 171 75 187 89 33 33 45 151 61 164 72 43EQS 57 65 270 102 295 121 43 33 45 224 79 244 94 54 50 65 455 144 496 171 68 50 65 576 181 684 215 97 50 65 821 259 976 307 118 50 65 1003 316 1192 375 127 50 65 1079 ~ 1283 404 --Table Notes 1. Capacities based on AISl S100-07 Section E4. See table on page 5 for design thicknesses. 2. When connecting mnterlals or different steel thicknesses or tensile strengths, use the lowest values. Tabulated values assume two sheets of equal thlcknus are connected. 3. Capacities are based on Allowable Strength Design (ASO) and Include safety factor of 3.0. 4. Where multlple fasteners are used, screws are assumed to have a center-to-center spacing of at least 3 times the nominal diameter (d) s. Screws are assumed to have a center-of-screw to edge-of-steel dimension of at least 1.5 times the nomlnal diameter (d) of the screw. Load Paths All product load capacities are calculated per North American Specification for the "Design of Cold Formed Steel Structural Members. The 2007 edition (here after referred to as simply "NASPEC"). Illustrations of load instructions are amongst their relative product load tables located throughout this catalog. Figure to the right demonstrates different types of load directions mentioned in this catalog. n = Out-of-plane lateral load F-2 = In-Plane lateral load • F3 = Direct vertical and uplift load 131 139 78 150 gr 102 66 109 75 117 81 143 82 J 152 94 164 108 151 76 161 86 174 100 201 103 214 117 231 136 l 177 84 188 95 203 110 317 140 338 159 364 184 l 263 109 280 124 302 144 534 198 570 225 613 261 755 250 i 805 284 866 328 1130 356 1285 405 1476 468 1381 435 1569 494 1816 572 1486 468 1689 532 1955 616 6. Tension capacity Is based on the lesser of pullout capacity In sheet closest to screw tip, or pullover capacity for sheet closest to screw head (based on head diameter shown). Note that for all tension values shown In this table, pullover values have been reduced by 50 percent assuming eccentrlcally loaded connections that produce a non-uniform pull-over force on the fastener. 7. Higher values, especially for screw strength, may be obtained by specifying screws from a specific manufacturer. See manufacturer's data for specific allowable values and Installation Instructions. www.hUtf.us Company: st>ocifior. Address: PhonelFtt E-Mal: r Specffler"a commentt: 1 Input data -typo end dlomolot': Effective ombedmentdopth: Material: Evoluatton Selvlce Rel)OII: Issued I Vaid: ---~ ECLIPSE ENGINEERING. INC. 376 SWl!k.ffOr., Suile8 541-389-96591 Kwit llo~ TZ -CS :Ill (2) h...., • 2.000 in .. 1\-• 2.313 In. c.-is1ee1 ESR-1917 6/1/20181511/2017 Proof: Dfflsn method ACI 31&-I" Mech. Page: Project: &Jb.Projed I Poo. No.: Dato: S,_ lnslllation: -(Raoommended plala -nol calttJlalod) Profile: no profile ea .. _, cnd<od c:,oncnte, 2500, f,' • 2500 psi; h • 4.000 In. IMtanatlon: hammer drln.d hole, lnfflKdon COftdlllon: Dry 1:11-;.;1 Profta Anchor 2. 7 .3 e/2/2017 SAFE-'"i:T Refnforoement tensk>n: condiUon 8, shear. condition 8; no tupplementat splitting reWorcement present edge reh.fotoerneut none or< No. 4 bar s.!smk:loods (cot C, 0, E. or F) Tenslon load: yes (17.2.3.4.3 (l>)) Shaer load: yes (17.2.3.5.3 (a)) O.Omotry [ln.J & loodlng (lb, lnJb] z: st Cfo 6 : JtJ' _.--....---r-, X-- -----"',.......-:-0 0 --·· ,-~ ~ : i.."\-..:,...-.-..>----', : ----'Q· ~ \ -::{----------· "\-t>. ---·• " ~--:-·--.r. ;-:r \....<-~ ~ --J ~ '•.JC ......... ,... ... cti.ctecl .. -,,..,Mnt ........... Ollldlo,a .. fllf~ PROFIIM«'O(e)2003-2009~.t.Cl,"1...$Ak~ ..... ,~T~rJI. .. AC,.,_ - 1:11-;.;1 www.hftll.ua Profta Anchor 2.7.3 Paga: Project: Ccml)any. Spedfier; -•: Phone I Fax: ECUPSE ENGINEERING, INC. 376 SW BkJff Or .. Suite 8 541-35-9659 I Sub-Project I Poo. No.; Date: e/2/2017 E-Mal: 2 Proof I Utlllzatlon (Governing Cases) Dnl,involuH[lbJ Loadlng Proof Load Copaclty y......., P\lllout siringth 800 1107 Shear Staal S.-.ngth 400 1466 Loodlng o.t2 o~h ~ Combined tenslon end shear bads 3Wamlngs • Pia-CX>nSlder aN da!alls and hintS/wamlngS giv9n In tho datelod roportl Fastening meets the design criteria! 4 Remarks; Your Cooperation Duties utlllzotton P.~tf :"1 Sutua Ok -/28 OK -on I!!\• 1%1 Sutua i8 Ok • My end ol -end data~ In tho-.. concom sololytho UH ol Hiil l)<OdlJds and..., buod on thopftndpln, '°"1'das and NaJltty ragultlc,,o In ------dlrecllons and c,pa,811ng, ~ end Noembly lna1nJellons, Ille., lhot muol be a1rldly oomplod-bythouser. All~--.,....._flillrn, end-.,...spodllc-.. to beconduct9dprtortousifts the ,...'4nt HIii product. The mutts ~ lhe c:ak::utaUoiM can1ed out by me.. or the Softwwe ere based ........., on 1he data you put In. --you_.,. -~"" Iha -"'""""'Iha~ and tho -oltho -to be put In by you. MoteoYat, you _lOla .....,.._,, lo<ho"Mg tho-af the-chklted end ctoaradbyon a-', portic<IIM1y-rogardto compllance wllh °""""""" nonns and permits, prior 1o using them lo< your spaclllc ~-The Softwara serves only N an old 1o lnlerprat norm. end pannitl ""1outanygu-• tothe-ol-, tho-end lhe-oltha mulls ors..-,. for• spocillc: oppllcatm. • Ycu lT'AJII tokoel nocoawy end --to-1 orltmlt--eouood bytho Software. In-. you muol8ff8ft!IO lo<tho Ng<Nr bac:kup olprogn,nw end -end, W appllcabla, c:.ry out tho updates ollha -..-by HI! on a_. basis. ttyou do not use tho AuloUpdD -af tho-.., you ..,st_,.. that you .. usifts tho cuiront end Illus up-tO<lata VOBlon ol lhe Software In aech case by conytng cut --' upd-vte tho 1W Website. Hilli wtl not be liable lO< ~•. such•• Iha ....,.,.ry al los1 or damaged data or programs, ansr,g from • ~ -ol duty by you. lr,paldaland~ft'IUll:bad'ieoedb ...... wlttb .... Ollflltllol'llandfor~ ~Ardr'1f(c)~twl/Jltl,f\.,t,ilt,t~ t9111•~,...........d .. AG.Sctw.l www.hltll.us Company: Specifier: Address: Phone I Fax: E-Mal· SpKfflrer'• comm.ma: 1 Input data Anchor type and c:Narneter. Effec:t!Ye embecsnent depth: Material: Evaluollon Service Repo,t tvsued I Vaid: Proof: ECUPSE ENGINEERING 376 SW Bluff Dr., Suite 8 5'11-389-9659 I Kwit Bolt TZ -CS 311 (2) h,,_., • 2.000 In., h.-• 2.313 In. Catbon Steel ESR-1917 61'1/2016 J 511/2017 Deoign method ACI 318-14 / Medl. a.= 0.000 In. (no stand-off); 1 • 0.074 In. Page: Projec:t: Sub-Project I Pos. No.: Date: i=IISi.u Profts Anchor 2.7.3 8/2/2017 SAFE--ET Stand-off lnstatlation: -plate: I, x ~ x I• 3.000 In. X 10.000 In. X 0.074 In.; (Reoommended plele -.: not cal<ulaled Profile: no proftle Base mat&rial: cracked concrete. 2500, fc' ,. 2500 psi: h == 4.000 In. lnatanatton: hmmer drilled hole, Installation condition: Dfy Refoforcement tension: condition 8, sheer: condition B: no suppHtmental splitting reinforcement present edge reinfon::ement: none or < No. 4 bar S-loads (cal C. D, E. or FJ Tensk>n load: yes (17.2.3.4.3 (b)) ShM• lood: yes (11.2.3.5.3 <•II Goomotry On.) & Loading (lb, In.lb) z §t C.\ L y_ •• ~ ____ .....,____ 0 -- ;lf. ----~----~&rn~J -~ l)i."'\.;---------}\: •.:.:--·· -~~ \__. . .... .. ''-.. ,--· -.:')r ~ J_ .. ' N --~~~---~• _j , ~ -----, ----··a 0 \ ---~ ~ \________ -~ ' -\.,. __.. ' ]...-~ \.--- ripa1:-.atldtN11111ftati.CMdlldb .--a.e,_...,......,..._..~ PROASN'dwtl(c)2003,-2009,_Nl.R. ...... SNM ,_lt•~T~clHlt!NJ.~ •• X www.hllll.us Company. 5-ffior. Page: Pn,ject i=iiS-li Profls Anchor 2.7.3 Address: ECLIPSE ENGINEERING 376 SW BM! Dr., Suite 8 5'11-389-9659 I Sub-Project I Poo. No.: Phone I Fax: Dete: E-Mal: 2 Proof I Utlllzatlon (Governing Cases) Dnfvn val-[lb) Loadlno Tention -N1out sireiijih Load C.S,aelty 300 1107 Shea, Concrete edge failure In dlreclon ,:+ <00 2055 Loading Combined tens,on end shear ioads & o.~95 ~ 3Wamlngs • Pie-~-al-end -.m1ngs given In the detalod reportl Fastening meets the design criteria! 4 Remarks; Your Cooperation Duties 8/2/2017 utlllntlon ~l.f,1"11 Status 28 • oK -/20 OK utt-"!!!!•1"11 Status 19 oK • My end al -end -c:cntalned In the Softwant"'"""'" solely Iha use of HIii pn,duds end""' boHd on the prtncli,les. f<>nTues end HCUlfty -,1111ons 1n aocordlnce wtlh Hllll's tedwllcal dlredlono end .,,,.ming. "10<Jnllng ond esNffibly mtrudlons, elc., lhat must be s1rlclly compled-by Iha user. All llgurn ~ -are -llgures, ond lhoro-.,....poo111c tes1$ .. to be conduc:lod prior to using the,,,_ HIii pn,ducl The l90ufts of the colcul....,. canied out by means olthe Softwere •"'-~ on the date you put In. Themoro, you -the -l9Sponsibllly to, the..,_ of omn, the comp,,-and Iha releY8nce of the data to be put In by you. --. you --~ lot hOYlng Iha rwsu1s olthe-chod<od and cleared byan expe,t. pe,tia,larlywllh ._,i to con.,a.,c:. wtlh oppllcoble _,.. and pom,lts. prior to using lhem to, your spedllc lacllty. The SO-..... , only es on aid to lnte=t norms end pemib without erry guarantee as lo the ebHnce of 9ff'Or'li, the com,ctneu and the relevance of the resutb or suitabiity for• lf)Odfic applealion. • You must tok• el ,,..,......, ond ,.,,__ stops to pr.....t or..,,. damalJo caUNd by the Software. In po-. you must arrange lot the -,ar bed<IJ!I of progrll!M and data and. W appfal>lo, c«ry out the updatfl of the Softwant offered by HIii on a "'9<Uf basls. Wyou do not use the AutoUl>date -of Iha Softwant, you must --you ... using the QJIT9nl end !hos up-lC><!ate version ol lhe --In each C&H by C8ITying out manual updatfl vie lhe Hllli Wobslo. HIii wll not be liable for consequences, sud> H the ,-y of lost or damaged data or programs. arising "'°"' a aApoble -ol duty by you. ................. CMdtMIDf..--C"91 ................ ~ M0'9SJ.,d,w,,( c ) 200.1-200t,_NJ, A.. ... M~ .. ll•~T~el .. AG.Sc:hN,, GJ -- ® • ~ " a ~ i • . ~ ! ~ ~ ~ I ffl I I ; -£ -- I ® • 'f' . ill ii • ~ ~I I I I ~ ~ s ·~ ~ gi ffl~--=~· ~ Eot:l.01U17W ~,- I~ • ' • • ' • • ' F • ] i • • I' r} PIPP RIVET STYLE STEEL STORAGE RACK DETAILS -- ::; ~ II ~ 11 ~ ~ . !I !• '::, P.0.125416 S.0.182396 BATH 6 BODY WORKS #305 THE SHOPPES AT CARLSBAD 2626 EL CAMINO REAL -SPACE #22ti CARLSBAD,CAUFORNIA92008 ':>c;:,c;:,c::,c;:,c,;:,c,;:, !Z> q, ';) Q c;:, "'-' Q,.:;:, ~ I \ v' . \\ I • • ~~ECLIPSE t124l E N G I N E E R I N G ~\f lj f, ~ ! November 3, 2017 BOGART CONSTRUCTION 9880 Irvine Center Drive, Ste. 200 Irvine, CA 92618 44444 Buena Vista Way Lancaster, CA 93536 (661) 202-4072 Office richard@actionspecialinspections.com I.C.C. / A.C.I. / A.W.S. Certified • Structural Steel & Welding • Reinforced Concrete • P .T. Concrete · Structural Masonry · Drilled-In Anchors · Epoxy Injection · Fireproofing • Shear Nailing ASI Job# 2711-17 SUBJECT: SATISFACTORY COMPLETION OF WORK REQUIRING SPECIAL INSPECTION PERFORMED UNDER PERMIT NUMBER: BUILDING PERMIT NO.: CBC2017-0157 PROJECT NAME & ADDRESS: BATH & BODY WORKS 2525 El Camino Real Carlsbad, CA 92008 This Jetter is provided to certify Special Inspection Final Compliance for the project referenced above. This certification includes inspection pertaining to: -Wedge Anchor Bolts Based on the observation and inspection performed by Action Special Inspections the above- referenced project has been, to the best of my knowledge, completed in accordance with the approved plans and specifications and the applicable provisions of the California Building Code. Should you have any questions or need further information please do not hesitate to contact this office. R~j:•,L_ ACTION SPECIAL INSPECTIONS Richard McKeehan \ ., .... ··-.. -~. -·· Jq; ... . .. ·'tli'Amse • ~ R~n.: ,z. /4_ o,or I ~~mrie,p.-•. --'g-...:C..=::~=:::c.e.e:=i..:1&1J11£.-....., * pS8l'-e'f'5 , . t 1 b I 1 • Oftilll,;T □Yeo.~ atlWJIJ I J1 C t t •. 8tJap . .__, __ ,..,. .... _ _. ..... 1 .. , ... , .... ___ ...... __ TYP£0Pwm«: (did: oaeJ.i(lrfdued 0.,.. 0 ~ 11d nn,.,., Q Ma-, fJ Weldill,g QIClllllf ____________ _ DellllliptioD of Wort: · ½/ff(?( C, ,4y«;.,C t # '?. C 0 I . • §j Ol?iW' :£ 6,A C ::!1': ~ !Cl Q"Y) C --; PP'crV1 OC.O ~T . ::q.,.¥Pttte ~»i...,, c, ~ , c % c:!>f' AMC~ ~""'•:"½< -1V>, f&:f < tH' «c·S . s, 1 JO: (Print"-) --·····-··-···-·· ... -,. . -. ~Tµ hO ~ P,-o,jecl# --~ fS;,Q:t •g• I• = I I »II II•! zszs-f..t.. ~ i<.,{,C) ~ ~'54D /0/10 .. .. . 'lklpadlilile 1'7 . L: -, • • --' ClirliE • .,,. 'r> I Jltz::. '. ....., t~Ol~ -~· ~R~n. ,;z:. "'"' ••=· tElre I ~~-,-,...,1,w, g, C..c>Vl~ ' -CeiM;f:atSit&;,l;I,\~ *s:z~8lC-1~ ~--. . Gi,i' .. ·-.... ~ ..... . •· Ollidlili1 □Y-~ ~l ,Jl O -------------- nm OP WOK: (ciltd: ->Ji(LWnllwced ~ 0 l'll...t: 1 , o..n-0 M--, 0 Welding □011111'------------- DellCdption of Work: ½/If PC :C-A,14Crt \ ICl!"2-~ ~ .PPo-vt oeo Ce<:-r . ::::Ei1?9vr& ::a:::,.:n"',<:.:, <a,-\. , o ,; c!>:f' ~-s. "Xvl.~T"A<-c,4!,0, AiJllWWldi>!'--------------- (Priut N11111<1} November 3, 2017 BOGART CONSTRUCTION 9880 Irvine Center Drive, Ste. 200 Irvine, CA 92618 44444 Buena Vista Way Lancaster, CA 93536 (661 J 202-4072 Office richard@actionspecialjnspections.com I.C.C. / A.C.I. / A.W.S. Certified • Structural steel & Welding · Reinforced Concrete • P.T. Concrete • Structural Masonry • Drilled-In Anchors • Epoxy Injection • Fireproofing • Shear Nailing ASI Job# 2711-17 SUBJECT: SATISFACTORY COMPLETION OF WORK REQUIRING SPECIAL INSPECTION PERFORMED UNDER PERMIT NUMBER: BUILDING PERMIT NO.: CBC2017-01S7 PROJECT NAME & ADDRESS: BATH & BODY WORKS 2525 El Camino Real Carlsbad, CA 92008 This letter is provided to certify Special Inspection Final Compliance for the project referenced above. This certification includes inspection pertaining to: -Wedge Anchor Bolts Based on the observation and inspection performed by Action Special Inspections the above- referenced project has been, to the best of my knowledge, completed in accordance with the approved plans and specifications and the applicable provisions of the California Building Code. Should you have any questions or need further information please do not hesitate to contact this office. ~5:·,l_ ACTION SPECIAL INSPECTIONS Richard McKeehan