Loading...
HomeMy WebLinkAbout2526 Glasgow Dr; ; CBR2018-3222; PermitCcityof Carlsbad Print Date: 04/29/2019 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2526 Glasgow Dr BLDG-Residential 2081910900 $6,041.70 Residential Permit Work Class: Patio Lot#: Reference#: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Description: VISCO: 490 SF DETACHEO PATIO COVER Applicant: SWIFT PERMITS DAV1D JONES 15641 Maturin Or San Diego, CA 92127-2331 619-884-9188 BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL Total Fees: $1Sl.98 Total Payments To Date: $151.98 Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Permit No: CBR2018-3222 Closed -Finaled 11/19/2018 12/27/2018 TFraz 4/29/2019 1:56:45PM $0.00 $88.3S $61.84 $1.00 $0.79 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov ('cicyof Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 Plan Check0{?)'2-2 Q\2S°-32??- Est. Value l Q 1 04\ PC Deposit --------- Date ---'-'\\-=+\9=----....1.\'o,._,_ __ Suite: ____ APN: __________ _ CT/Project #: __________ Lot#: ____ Fire Sprinklers: yes/ no Air Conditioning: yes/ no BRIEF DESCRIPTION OF WORK: _ _.__?q--'-h_o---'{,"'0""1,t:.:Y _ __,~=--l-}('--'2"-'-4....:'t,=---"-------------- }fer,_vf 7t ½ eev: '-11~ fl-.' JiO Addition/New: _____ Living SF, ___ Deck SF, i, 'fl~ Patio SF, ___ Garage SF Is this to create an Accessory Dwelling Unit? Yes/ No New Fireplace? Yes/ No, if yes how many? __ D Remodel: ____ SF of affected area Is the area a conversion or change of use ? Yes/ No 0 Pool/Spa: ____ SF Additional.Gas-er Electrical Features? ____________ _ □ Solar: ___ KW, ___ Modules, Mounted: Roof/ Ground , Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No Panel Upgrade: Yes/ No D Reroof: ___________________________________ _ D Plumbing/Mechanical/Electrical Only: ________________________ _ D Other: __________________________________ _ APPLICANT (PRIMARY) PROPERTY OWNER Name: ::Pt>..v,d TONS Address: 9 CZL\5 .Al/.,.. ~C WA.y City: ?'I ti ~o State: (. ,f-Zip: 4' '2 /'2 IP Phone: 10 !-J-~'-141&8 Email: ]\a~,d@s,.,,,fl r~" ko"'1 DESIGN PROFESSIONAL Name: _________________ _ Address: ________________ _ City: ________ State:. ___ Zip: ____ _ Phone: ________________ _ Email: ________________ _ Architect State License: ___________ _ Name: 1/J~ R~,d~ Address: '2.7-Zt., &,\qs~ol.v City: /gvlt, 110,0, State: IA: Zip: 'f ZQ Ill Phone: __________________ _ Email: ___________________ _ CONTRACTOR BUSINESS Name: LYi 1)()!,r1}\'\ Address: po &:t fl/Ill City: ?,!It! .MArtos State: ( A: Zip: _7.,_z.,.n.._J,_1..__ __ Phone: <?~~ -(p<,, i'-"78]1 Email=-------------.,,------- State License: 1 '6281/ Bus. License: 8LtYtvol//l-/l-U>/1 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov B-1 Page 1 of 2 Rev. 06/18 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: □ I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. illl I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the P.erfprmance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: lnsura'!thompany Name: _ _;l>=..,-fe,c,:i_~,:::,__,{c,o,ejM~P,,:.• _____________ _ Policy No. <j/5515/ Expiration Date: -""'1-'-P...:ll=!J.,...l'I,__ ___ _ □ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage ls unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. CONTRACTOR SIGNATURE: --J2t...,,l,L-'n:<c'<~~w1=· ___:_~~==-------~AGENT DATE: __,_!.._,I /f--lt_,.,_,_/.,_l .,_9_ ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: □ l, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). □ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor{s) licensed pursuant to the Contractor's License Law). □ I am exempt under Section ________ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No 2. I {have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): 5. I will provide some of the work, but J have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work): OWNER SIGNATURE: __________________ □AGENT DATE: _____ _ CONSTRUCTION LENDING AGENCY. IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued {Sec. 3097 (i) Civil Code). lender's Name: _____________________ _ Lender's Address: _____________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CllY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations overS'O' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). APPLICANT SIGNATURE: _, )4"-£--'~'--..... ·'--~v_,,.~"'--'-'-"'-----------DATE: _/.-JI /,CLJ_,.f4-/2-'-'J/'---- 1635 Faraday Ave Carlsbad, CA 92008 B-1 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of2 Email: Building@carlsbadca.gov Rev. 06/18 PERMIT INSPECTION HISTORY REPORT (CBR2018-3222) Permit Type: BLDG-Residential Application Date: 11/19/2018 Owner: RANCHO COSTERA LLC Work Class: Patio Issue Date: 12/27/2018 Subdivision: Status; Closed -Finaled Expiration Date: 09/09/2019 Address: 2526 Glasgow Dr IVR Number: 15548 Carlsbad, CA 92010-5602 Scheduled Actual Primary Inspector Reinspection Complete Date Start Date Inspection Type Inspection No. Inspection Status 0110312019 0110312019 BLDG-11 080321-2019 Passed Chris Renfro Complete Foundatlon/Ftg/Pler s (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 02/01/2019 02/01/2019 BLDG-14 082866-2019 Passed Tim Frazee Complete Frame/Steel/Baiting/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Structure framing OK Yes BLDG-83 Roof 082971-2019 Passed Tim Frazee Complete $heating, Exterior Shear (13, 15) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-15 Roof Yes Sheathing-Reroof 03/12/2019 03/12/2019 BLDG-55 085833-2019 Pas·sed Tim Frazee Complete Fence/Preplaster Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 04/29/2019 04/29/2019 BLDG-Final 090217-2019 Passed Tim Frazee Complete Inspection Checklist Item COMMENTS Passed BLOG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes Aprll 29, 2019 Page 1 of 1 ✓• EsG1I A SAFEbwlt Compnny DATE: December 12, 2018 JURISDICTION: Carlsbad D APPLICANT D JURIS. PLAN CHECK#.: CBR2018-3222 PROJECT ADDRESS: 2526 Glasgow Dr. SET: II PROJECT NAME: New patio cover for Visco Residence □ □ □ □ □ rgJ □ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: David Jones EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: 619-884-9188 onm (by~) Email: Date contacted: david@swift-permits.com Mail Telephon Fax In Person 0 REMARKS: By: Kat Frankowski EsGil 12/6/2018 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 , DATE: November 29, 2018 JURISDICTION: Carlsbad ✓• EsG1I A SAFEbuilfCompany PLAN CHECK#.: CBR2018-3222 PROJECT ADDRESS: 2526 Glasgow Dr. SET: I PROJECT NAME: New patio cover for Visco Residence □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. r:gj The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. r:gj The applicant's copy of the check list has been sent to: David Jones D EsGil staff did not advise the applicant that the plan check has been completed. r:gj EsGil staff did advise the applicant that the plan check has been completed. Person contacted: David Jones Telephone#: 619-884-9188 ) Email: david@swift-permits.com Date contacted: (by: Mail Telephone Fax In Person 0 REMARKS: By: Kat Frankowski EsGil 11/20/2018 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBR2018-3222 November 29, 2018 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: CBR2018-3222 PROJECT ADDRESS: 2526 Glasgow Dr. FLOOR AREA: Patio = 490 SF REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 11/19/2018 DATE INITIAL PLAN REVIEW COMPLETED: November 29, 2018 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad STORIES: HEIGHT: DATE PLANS RECEIVED BY ESGIL CORPORATION: 11/20/2018 PLAN REVIEWER: Kat Frankowski This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2016 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC, 2015 UPC, 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBR2018-3222 November 29, 2018 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Kat Frankowski BUILDING ADDRESS: 2526 Glasgow Dr. BUILDING OCCUPANCY: BUILDING PORTION Patio Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb 1997 USC Buildin Permit Fee g 1997 USC Plan Check Fee Type of Review: D Repetitive Fee ::::3 Repeats Comments: AREA Valuation ( Sq. Ft.) Multiplier 490 By Ordinance ... Complete Review 0 Other 0 Hourly EsGII Fee PLAN CHECK#.: CBR2018-3222 DATE: November 29, 2018 Reg. VALUE ($) Mod. 6,041 6,041 D Structural Only t------tl Hr. @ • $53.671 Sheet of Carlsbad CBR2018-3222 November 29, 2018 PLANS 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. Indicate on the Title Sheet of the plans the name of the legal owner and name of the person responsible for the preparation of the plans. Section R 106.1.1. 4. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 5. Plans deviating from conventional wood frame construction shall have the structural portions signed and sealed by the California state licensed engineer or architect responsible for their preparation, along with structural calculations. (California Business and Professions Code). 6. Clearly dimension building setbacks from property lines, street centerlines, and from all adjacent buildings and structures on the site plan. Section R106.2. Show set back to wall, as well as roof overhang. FIRE PROTECTION 7. Exterior walls and projections shall comply with one of the following tables. Section R302.1. Please review and address the following specific concerns: a) Use this table if the building DOES NOT have an automatic fire sprinkler system. Exterior Wall Element Min. Fire Rating Min. Fire Separation Distance Walls I (Fire-Resistance Rating) 1-hour, with exposure < 5 feet from both sides Carlsbad CBR2018-3222 November 29, 2018 (Not Fire Rated) Not Allowed Projections (Fire-Resistance Rating) (Not Fire Rated) Not Allowed Wall Openings 25% maximum of wall area Unlimited Penetrations All 0 hours 2: 5 feet N/A <2 feet 1-hour on the ;;, 2 feet to 5 feet underside a 0 hours ;;, 5 feet N/A < 3 feet 0 hours 3 feet 0 hours 5 feet See Sec. R302.4 < 5 feet -None required 5 feet a May be reduced to O hours on the underside of the projection if fireblocking is provided from the wall's top plate to the underside of the roof sheathing. FOUNDATION/ STRUCTURAL 8. Show 3" clear cover for reinforcement in foundation. 9. Show a corrosion resistant weep screed with a minimum vertical attachment of 3.5" at or below foundation plate line on exterior stud wall. The weep screed shall be placed not less than 4" above the earth or 2" above paved areas. R703.7.2.1 ROOFS/DECKS/BALCONIES 10. Specify on the plans the following information for the roof materials, per Section R106.1.1: a) Manufacturer's name and product name/number. b) ICC approval number, or equal. MISCELLANEOUS 11. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 12. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ 13. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Kat Frankowski at EsGil. Thank you. DANIEL KORNTVED STRUCTURAL ENGINEER 2546 Montclair Street San Diego, CA 92104 619-841-8241 STRUCTURAL CALCULATIONS for VISCO RESIDENCE PATIO COVER CONTENTS: Framing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I _ 3 Lateral Analysis. . . . . . . . . . . . . . . . . . . . . .... 4 _ 5 Footings . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . 6 . Daniel P. KORNTVED STRUCTURAL ENGINEER 2546 MONTCLAIR ST SAN DlEGO.CALIFORNIA92104 V1~0 ~~\ ~X.E:' -PA.TTO C.O•J€t?. , 4 ---·f < I ! I I I ! i I r_ --'==-..,__--tFf.---- ROOf: f\?-Ny\\{\)(-l PLAN 'I"¾."= \'-o 11 12,oo f' C>L..;;. zo P:,F Rao(" l...l .::: 20 pSf" PHONE/ (619) 841-8241 '. ' -, I. Rev S10300 Timber Beam & Joist Description VISCO RESIDENCE Timber Member Information RB1 RB2 RB3 RB4 Timber Section Beam Width Beam Depth Le: Unbraced Length Timber Grade Fb -Basic Allow Fv • Basic Allow Elastic Modulus Load Duration Factor Member Type Repetll:ive Status Center Span Data Span Dead Load Live Load Point #1 DL LL @X Point #2 DL LL @X Point #3 DL LL @X Point #4 DL LL @X 4xs 4x8 6x10 6x12 RJ1 4x6 3 500 3.500 5 500 5.500 in 3.500 · 11.500 in 5.500 7.250 7.250 9 500 ft 0.00 0.00 0.00 7 50 0.00 Jouglas Fir_ Larch Jouglas Fir -Larch Douglas Fir• Larch. Douglas F,r -Larch. Douglas Fir· Larch, psi 1 000 0 1,000.0 1,000 0 1,350.0 1,350.0 psi ' 95 O 95.0 95.0 85 0 85 0 ksi 1,700:0 1.700 0 1,700.0 1,600 0 1,600 0 ft #/ft #/ft lbs lbs ft lbs lbs ft lbs lbs ft lbs lbs ft 1.2~ 1.~ 1~ 1.2~ 1.= Sawn No Sawn No 7.50 60.00 6000 ;a Q40 Sawn No 1000 300.00 300 00 2.000 160.00 160.00 4.000 120.00 120.00 6.000 60.00 60.00 Sawn No 5 00 150.00 150,00 Sawn No 15.00 444,00 444 00 7.500 444.00 444.00 7,500 375.00 375.00 7.500 20.00 70.00 70.00 635 10 635.10 7.500 635.10 635.10 12.500 Page 1 I ' Cantilever Span ~ -------------"""'"'""'""'""""""'~-----"""'"''" ________ .,.. ___________ ,..,11 Span Uniform Dead Load Uniform Live Load Results Mmax@ Center @Xa Mmax @ Cantilever fb · Actual Fb · Allowable fv Actual Fv : Allowable Reactions @ Left End DL LL Max DL +LL @ Right End DL LL Max. DL+LL Deflections ft #/ft #/ft Ratio= 2.50 60.00 60.00 0.3150 in-k 9 03 ft 3.54 in-k ~4.50 psi 511.8 psi 1,625.0 Bending OK psi 34.8 ps, 118.8 lbs lbs lbs lbs lbs lbs Shear OK 200.00 225,00 425,00 400.00 400 00 800.00 za:: 06105 22 46 4 00 0 00 732.6 1,200.0 Bending OK 45.4 95,0 Shear OK 444.00 444.00 888.00 196.00 196 00 392.00 A 0.3547 11.25 2.50 0.00 366 9 1,200.0 Bending OK 33.7 95,0 Shear OK 375.00 375.00 750.00 375.00 375 00 750.00 0.8204 113 67 7.50 0.00 1,374 0 1,674,9 Bending OK 36.3 106 3 Shear OK 631 50 631.50 1,263 00 631.50 631,50 1,263 00 0.9694 198.32 1000 0.00 1,635 9 1,687.5 Bending OK 60.4 1063 Shear OK 1,33510 1,335 10 2,670.20 1,335 10 1,33510 2,670 20 • w zuaun:w: wt I J Rev 510300 Description Center DL Defl L/Defl Ratio Center LL Defl UDefl Ratio Center Total Defl Location UDefl Ratio Cantilever DL Defl Cantilever LL Def! Total Cant. Deft L/Defl Ratio VISCO RESIDENCE ,n -0038 2,363.5 in -0.052 1,738.2 ,n -0 090 ft 3.660 1,002.3 in 0.025 in 0.025 in 0.049 1.220.0 Timber Beam & Joist "' Page 2 I -0.083 -0.011 -0.244 -0.526 1,443 8 5,374 8 737.5 456.5 -0083 -0.011 -0.244 -0.526 1,443.8 5,374.8 737.5 456.5 -0. 166 -0.022 -0.488 -1 051 4.720 2.500 7.500 10.000 721 9 2,6874 368.8 228.2 U.S. Seismic Design Maps 2526 Glasgow Dr, Carlsbad, CA 92010, USA Latitude, Longitude: 33.1550935, -117.3070252 ' Go Date Design Code Reference Document Risk Category 10/30/2018, 915:20 PM ASCE7-10 II Site Class Type Value Ss 1.088 S, 0.419 SMs 1.159 SM, 0.662 Sos 0.773 So, 0.442 Type Value soc D F, 1.065 F, 1.581 PGA 0.422 FPGA 1.078 PGAM 0 455 T, 8 SsRT 1.088 SsUH 1126 SsD 1.5 S1RT 0.419 S1UH 0.412 S1D 06 PGAd 0.512 CRs 0.966 Description MCER ground motion. (for 0.2 second period) MCER ground motion (for 1.0s period) Site-modified spectral acceleration value Site-modified spectral acceleration value Numeric seismic design value at 0.2 second SA Numeric seismic design value at 1.0 second SA Description Seismic design category Site amplification factor at 0.2 second Site amplification factor at 1.0 second MCE:.G peak ground acceleration Site amplification factor at PGA Site modified peak ground acceleration Long-period transition period in seconds Probabilistic risk-targeted ground motion. {0.2 second) D -Stiff Soil Factored uniform-hazard {2% probability of exceedance in 50 years) spectral acceleration Factored deterministic acceleration value. (0.2 second) Probabilistic risk-targeted ground motion. (1.0 second) Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration Factored deterministic acceleration value (1 0 second) Factored deterministic acceleration value. (Peak Ground Acceleration) Mappeo value of the risk coefficient at short periods https://seismicmaps.orgl l:'agc-1701 J OSHPD Ma;1 data;;-: 2018 Google I 0/30/2018 Daniel P. KORNTVED STRUCTURAL ENGINEER 1546 MONTCLAIR ST SAN DIEGO, CALIFORNIA 92104 w' T€WAL --/<J,Jfl-:.G<-1-SIS \Je.roF ~ Z.0'1--z.s' 'I.. Wp7F · /OWO 4t= V5£ts:. O . =3.C::, ~ Kn---i,•y) --. 3 bO:") 4t-- \/~, ~i;; :: ~z.:.. \ ?r:;o~ MYO::if = °'.tf)() l\ ~ \.J>f'" g~ Vloo t) i Ro~l"S -------- ', ~b:.-90QJx \y7DJf,i3, tSGO f~i rl?=-\.3~"" \~1:l)r·,:: p+·< (;':JI -~------·,--·· t ' I D "· I Sp&r· 3a:,*/ 'sz:+r/ ,-; : 49:')#"/, PHONE/ (619) 841-8241 Daniel P. KORNTVED STRUCTURAL ENGrNEER 2546 MONTCLAIR ST SAN DIEGO, CALIFORNIA 92104 p~ FTg L.D'f..:z.,s' ( -z..ot -z..oesf) '-\ .,,,. txt:v it Description POST FOOTING General Information Allow Passive Max Passive Load duration factor Pole is Rectangular Width Restrained @ Surface Moments @ Surface ... Point load Distributed load Without Surface Restraint ... Required Depth Press@ 1/3 Embed .. Actual Allowable 250.00 pcf 1,500.00 psf 1.330 24.000 in 900.00 ft-# 0.00 0.000 ft 0.00 psf 000 psf Applied Loads ... Point Load distance from base Distributed Load distance to top distance to bottom Total Moment Total Lateral With Surface Restraint. .. Req'd Depth Pressure@ Base .. Actual Allowable Surtace Restraint Force PHONE/ 900.00 lbs 1.000 ft 0.00 #/ft 3.000 ft 0.000 ft 900.00 ft-# 900.00 lbs 1.598 ft (619) 841-8241 ------------------