Loading...
HomeMy WebLinkAbout2526 LA GOLONDRINA ST; ; CB921135; PermitBUILDING PERMIT 02/02/93 12:53 Page 1 of 1 Job Address: 2526 LA GOLONDRINA ST Suite: Permit Type: RESIDENTAL ADD/ALT Parcel No: 215-561-08-00 Lot#: Valuation: 48,941 Construction Type: VN Occupancy Group: R3 Ref erence#: Description: 412 SF ADD + 165 SF DECK + KIT REMODEL Permit No: CB921135 Project No: A9202330 Development No: 1033 02/02/93 0001 01 02 C-PRMT 539 00 Status: ISSUED Applied: 10/22/92 Apr/Issue: 02/02/93 Entered By: DC Appl/Ownr : PARADISE, DENNIS 619 438-9224 2526 LA GOLONDRINA - CARLSBAD, CA 9209 ** Fees Required .k 1 .-' C!lected & Credits Fees: 7 15 4uO Adjustments: / - / -'ot- :rit-.'. .00 Total Fees: / 74,r / Pvet. 215.00 Bala':- p'--• 539.00 Fee description -. -- -. -Ut3 \ /U:t Ext fee Data - -T --- -- - -. --- _________________ Building Permit I 0 f 408.00 Plan Check ( \ / u J 265.00 Stronq Motion Fee 5.00 * BUILDING TOTAL \ J (I-)J;' 678.00 Enter "Y for PlumUii. 1.uL' . I , 20.00 Y Each Plumbing Fixt\x or 'p 7' 4 / / . 14.00 Each Building Sewer\ > - ..9 15.00 \ NCr 'HA / Gas Piping System 1 .' '-00 7,00 * PLUMBING TOTAL _- 0 56.00 Enter 'Y" for Electric\Tjc-.'F'e 10,00 Y Enter "Y " for Remodel / '- '- 10.00 Y A ELECTRICAL TOTAL - 20,00 INSP. 'APPROVAL DATE ..z. CLEARANCE CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 c44~q3 / B U I L D I N G P E R M I T Permit No: CB921135 07/2 /93 10:44 Project No: A9202330 Page 1 of 1 Development No: Job Address: 2526 LA GOLONDRINA ST Suite: Permit Type: RESIDENTAL ADD/ALT Parcel No: 215-561-08-00 Lot#: 380 07/27/Q7 0001 01 02 Valuation: 48,941 c-p ioo Construction Type: VN Occupancy Group: R3 Reference#: Status: ISSUED Description: 412 SF ADD + 165 SF DECK ± KIT Applied: 10/22/92 REMODEL Apr/Issue: 02/02/93 Entered By: DC Appl/Ownr : PARADISE, DENNIS 619 438-9224 2526 LA GOLONDRINA CARLSBAD, CA 92009 *** Fees Reciuied )1.?cted & Credits ------------------------/__J -- Fees cj (0 1 r Adjustments: I 00 Total Fees / 79 / 'fr' OtcJ. P5tt 754 00 Blane. 19-00 Fee description \ Ext f ee Data Building Permit I 0 p\ 408.00 Plan Check 0 265,00 Strong Motion Fee - iV 5.00 BUILDING TOTAL . / 678 00 Enter Y for Plumbatj 20.00 Y Each Plumbing Fixture or Trap Each Building Sewer > 1 5 Gas Piping System N CO ( 7 0 * PLUMBING TOTAL Enter "V for Electric ' Fe Other N LI 7 * ELECTRICAL TOTAL - FINAL APPROVAL :NSP. -DATE CLEARANCE CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 14.00 15. 00 7.00 56.00 10.00 Y 25.00 UPT0200AMP 35.00 PERMIT APPIICA11O4 S City of Carlsbad Building Department 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 1. PERMIT TYPE A - 0 Commercial U New Building U Tenant Improvement B - 0 Industrial 0 New Building 0 Tenant Improvement C - $Jesidential 0 Apartment 0 Condo 0 Single Family Dwelling Addition/Alteration 0 Duplex 0 Demolition 0 Relocation 0 Mobile Home 0 Electrical 0 Plumbing 0 Mechanical 0 Pool 0 Spa 0 Retaining Wall 0 Solar 0 Other. PLAN CHECK NO. ?2 //jj — EST. VAL PLAN CK DEPOSIT c2 /.S VALID. BY DATE oe 9804 10/22/92 0001 01 02 C-PRMT 215.00 2. PROJECT INFORMATION I FOR OFFICE USE ONLY Address Q5 L.i4 Building or Suite No. Nearest Cross Street COT. fN-r/4 LEGAL DESCRIPTION Lot No. subdivision Name/Number Unit No. Phase No. Energy Calcs Structural Calcs 02 Soils Report 1 Addressed Envelope DESCRIPTION OF WORK ADD - F,4-/'I1L'f x) SQ. FT. 4<D4, , # OF STORIES NAME PCW4L..f) ,pov4a.. ADDRESS IS L1vp.pL. PR, 'uI 7 CITE 4ZP 1FF 6Y -e ASTATE (4. ZIP CODE 1'2c71f-) 7 DAY TELEPHONE 43l -45/ NAME , (r13d,5(ADDRESS zIc,44 CITE Ce-rlh44 STATE (2,4, ZIP CODE (/2<0C9 DAY TELEPHONE - k'I{UFS.KIY NAME ,tlr. A M rs, €4J..4J1' ,y44d) (ADDRE55 CITE STATE ZIP CODE DAY TELEPHONE (X)NTRAC'IDR NAME ADDRESS CITE STATE ZIP CODE DAY TELEPHONE STATE UC. # LICENSE CLASS CITE BUSINESS UC. # DESIGNER NAME Qt ,4pcN,TEA #HLSS J3g p4 - , CITEC),-C. b 4k 'j STATE £ft. ZIP CODE 92ec'7 DAY TELEPHONE 4'J -4457 STATE IJC. # woiRIks WMPATRJN Workers' Compensation Declaration: I hereby affirm that I have a certificate of consent to sell-insure issued by the Director of Industrial Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. Q. INSURANCE COMPANY POLICY NO. EXPIRATION DATE Certificate of Exemption: I certify that in the performance of the work [or which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. SIGNATURE DATE OWNER-BUILDER DECLARA11ON Owner-Builder Declaration: I hereby affirm that I am exempt from the Contractor's License Law for the following reason: I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Cede: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). . I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Cede: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$5001). SIGNATURE DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? DYES ONO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? DYES ONO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? DYES ONO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING TIlE REQUIREMENTS OF 11W OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DIS'IIUCF. eretiy affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS 10. APPLICANT CERIlFICAllON I certify that 1 have read the application and state that the above information is correct. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, CX)STS AND EXPENSES WHICII MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by su.b1-permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permkJ suy591ed o5pI6ned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code). DATE:/' Zz--?z FInance Me CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB921135 FOR 12/07/93 INSPECTOR AREA TP DESCRIPTION: 412 SF ADD + 165 SF DECK + KIT PLANCK# CB921135 REMODEL 0CC GRP P3 TYPE: PAD CONSTR. TYPE VN JOB ADDRESS: 2526 LA GOLONDRINA ST STE: LOT: APPLICANT: PARADISE, DENNIS PHONE: 619 438-9224 CONTRACTOR: PHONE: OWNER: PHONE: REMARKS: MH/JOANN/438-9224 INSPECTOR _ ____________________ SPECIAL INSTRUCT: PERMIT IS ABOUT TO EXPIRE/WILL CALL I AM FOR TIME TOTAL TIME: CD LVL DESCRIPTION ACT COMMENTS 19 ST Final Structural 29 PL Final Plumbing 39 EL Final Electrical 49 ME Final Mechanical ***** INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP COMMENTS 080493 Final Combo CO TP SEE JOB CARD 060193 Exterior Lath/Drywall AP PK 051893 Interior Lath/Drywall AP PY 051893 Exterior Lath/Drywall AP PY 051293 Insulation AP TP 051293 Frame/Steel/Bolting/Welding AP TP 051293 Rough/Topout AP TP 051293 Rough Electric AP TP WALLS & CEILING ONLY 051293 Rough/Ducts/Dampers AP TP 050693 Frame/Steel/Bolting/Welding NR TP CORP NOT COMP 050693 Rough Electric NR TP 050493 Rough Combo CO TP SEE CALL SLIP/OK TO INStIL 042893 Rough Combo CO TP SEE LIST 042693 Rough Combo CO TP 031593 Underground/Under Floor AP TP EXTENSIONS 031593 Ftg/Foundation/Piers AP TP 031193 Ftg/Foundation/Piers CO TP PROFESSIONAL REGISTERED INSPECTIONS, INC 7895 Convoy Court San Diego, California 92111 Phone 292-061 INSPECTORS WEEKLY REPORT 1No.3 ENDING ON I....... COVERING WORK PERFORMED WHICH REQUIRED APPROVAL BY THE SPECIAL INSPECTOR OF J REINFORCED CONCRETE PRE-STRESSED CONCRETE Ll REINFORCED MASONRY l STRUCT. STEEL ASSEMBLY GLUE . LAM. FAGRICATIOI U REINFORCED GYPSUM OTHER PILE DRIVING . JOB ADDRESS o1zc'g C,/qcl BUILDING PERMIT NUMBER C92 //5-5' PLAN FILE NUMBER OWNER OR PROJECT NAME c/t e / . ARCHITECT CONSTR. MAT'L. (TYPE, GRADE, ETC.) DESIGN STRENGTH SOURCE OR MFGR. ENGINEER DESCRIBE MAT'L. (MIX DESIGN. RE-BAR GRADE & MFGR., WELD-ROD. ETC.) A Cr sle, Af c GENERAL CONTRACTOR/ CONTR. DOING REPORTED WORK LAB. RECEIVING & TESTING CONSTR. MAT'L SAMPLES INSP'N. DATE LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS, ETC INCLUDES INFORMATION ABOUT - AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED: NUMBER, TYPE, & (DENT. NO'S. OF TEST SAMPLES TAKEN; STRUCT. CONNECTIONS (WELDS MADE, H.T. BOLTS TORQUED) CHECKED; ETC. I AN cc/ 2 Y1 c-tc Aü/'r c ,'/, - e (9 / /J /c p s .. c/ oor y e / ~ ~ /-," "/, Zj, - SI NATURE OF R ISTERED INSPECTOR 2' DATE OF .EPORT REGISTER NUMBER ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 DATE: /1 - /7- JURISDICTION: C PLAN CHECK NO: 9 2113 SET: /J... PROJECT ADDRESS:2. PROJECT NAME: oP 4 1J 3URISDIC N PLAN CHECKER OFILE COPY E UPS DDESIGNER 119 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply El with-the jurisdict ion's building codes when minor deficien- cies identified are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. LI The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. LI The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. LI The applicant's copy of the check list has been sent to: Li Esgil staff didnot advise the applicant contact person that plan check has been completed. LI Esgil staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: Telephone LI REMARKS: Ey:L)L. Enclosures: SGILCOR I EJGA 11CM ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 DATE: JURISDICTION: CARLSBAD PLAN CHECK NO: /SET: 1 PROJECT ADDRESS: PROJECT NAME: c5 fl3URISDICT LJPLAN CHEC OFILE COPY o U PS f--.DESIGNER - r-1 Theplans transmitted herewith have been corrected where U necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the Jurisdiction's -building codes when minor deficien- cies identified are resolved and checked -by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a comolete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. fl The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: - IUcL b, Sr-c (?rrFCft 2007 fl Esgil staff did not advise the applicant contact person that plan check has been completed. Esgil staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: /1— 2 - - Telephone a5 /1?c?,/ []REMARKS: By: Enclosures: ESGIL CORPORATIOJ DGA El CM PLAN NO: _____________ JURISDICTION: CITY OF CARLSBAD PROJECT ADDRESS: CP //1L1 Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances by the Planning Department, Engineering Department or other departments. Present California law mandates that residential construction comply with Title 24 and the following model codes: 1991 UBC (eff. 8/14/92) 1991 UPC (eff. 8/14/92) 1990 NEC (eff. 7/1/91) 1991 UNC (eff. 8/14/92) The above regulations apply to residential construction, regardless of the code editions flOOR AREA: I V2 adopted by ordinance. STORIES: ]HEIGHT: PLAN CORRECTION SHEET crr OF CARLSBAD SINGLE FAMILY AND DUPLEX DWELLINGS Date plans received by jurisdiction: /// Date plans received by Esgil Corporation: ///9 Date initial plan check comleted:/) ///2)By: 6f, C, '1• Applicant contact person: CtVelephone: t7L3 "3 lOe The The circled items listed need clarification, modification or change. All items have to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303(c), 1991 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To Sneed up the recheck process, _note on this list (or a copy) where each correction item has been addressed i.e.. • plan sheet, specification, etc. Be sure to enclose the marked up list when you submit the revised plans. NOTE: PAGE NUMM ARE NOT IN SEQUENCE AS PAGES HAVING NO ITF4S NEEDING CORRECTIONS WERE DRr.rrF:D. List No. 2, Carlsbad Single Family Dwelling and Duplex With All Supplements. (1991 UBC) 7. Indicate distance from property lines to / proposed construction. Section 302(d). PLANS 1. Please make. all corrections on the original tracings and submit two new sets of prints, to: Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, California 92123, (619) 560-11468. /1. Please make all corrections on the original tracings and submit two new sets of prints, to: The jurisdiction's building department. 3/ Indicate on the Title Sheet of the plans, the name of the legal owner and name - of person responsible for the preparation of the plans. Section 302(a)7. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Co e). 5. Plans, specifications andcalculations shall be signed by the Californiastat1icensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction. Specify expirati:n date of license. (California Business and Professions Code). C_CL I c-.--s ccA_L 2f\.1 - o( Specify on the Title Sheet of the plans the gross floor area of each element of this project including dwelling, garage, carport, patio, deck and balcony. Section 302(d). Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1991 UBC, UMC and UPC and 1990 NEC. ie-, G-.-t. AJcYj I o rcILt,J Submit fully dimensioned plot plan drawn t0 scale showing location, size, and use of all existing and proposed structures on the lot. Identify property lines and show lot dimensions and all easements. Show location of all cut or j1L...alcwas.. Show finish floor elevations and — show 1. elevations of adjacent finish grade. 02d' with minimum Elopes. Section 10. Show on the title sheet all structures, pools, / walls, etc. included under this application. Any portion of the project shown on the site plan that is not included with the building permit application filed should be clearly identified as "not included." l( Clearly show if the lower level is abasement / or a story, based on the definitions in Sections 403 and 420. Plot the finish grade (as defined) on the elevations and dimension the distance to the floor above, for story determination. 17. On the cover sheet of the plans, specify any / items requiring special inspection, in a format similar to that shown below or sticky back. REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec. 306 of the Uniform Building Code. ITEM REQ. IF REMARKS CHECKED SOILS COMPLIANCE PRIOR TO FOUNDATION INS?. FIELD WELDING HIGH STRENGTH BOLTS EXPANSION ANCHORS SPECIAL MASONRY SPRAYED ON FIRE PROOFING PILES /CAISSONS. DESIGNER-SPECIFIED OTHER STRUCTURAL CONCRETE OVER 2500 PSI PRESTRESSED STEEL 11 - Exterior walls closer than 3 feet to property / lines shall be one-hour rated construction and have no openings. Table 5-A. 8/5/92 2 lk'L Exterior walls closer than 3 feet to a )' Sleeping rooms shall have a window or exterior 7 property line shall have 30 inch parapets when / height door for emergency exit. Sill shall the floor area per floor exceeds 1,000 square not exceed 44" above the floor. The window feet. See Section 1710 for possible exception. must have an openable area of at least 5.7 square feet with the minimum openable width 15<' Projections, including eaves, may not extend 20" and the minimum openable height 24". / more than 12 inches into the 3 foot setback Section 1206. from the property line. Section 504(b). 6. Basements in dwelling units shall comly with y. Eaves over required windows shall be not less /4the above (even if not designated as sleeping than 30 inches from the side and rear property rooms). Section 1204. lines. Section 504(a). / Window area must be at least 1/10 of the floor Projections, including eaves, shall be one-hour 7 area and a minimum of 10 square feet per / fire-resistive construction, heavy timber or of Section 1205 (b). Appears to be deficient in noncombustible material if they project into the 3' setback area from the property line. Section 1711. lft( / Plastic skylights shall not be installed within that portion of a roof located within a ,26. Openable window area in habitable rooms must distance to property line where openings in 7 be 1/20 of the floor area and a minimum of 5 exterior walls are prohibited or required to be square feet. In bathrooms, laundry rooms and protected. Section 5207 (a) 7. similar rooms 1/20 of area is required and minimum is 1.5 sq. ft. Section 1205 (c). 19. Show locations of permanently wired smoke detector with battery backup: 27 At least 1/2 of the coon wall must be open Inside each bedroom. and have an opening not less than 25 sq. ft. Centrally located in corridor or area nor one tenth of the floor area of the giving access to sleeping rooms, interior room if light and ventilation is On each story. being supplied from an adjacent room. In the basement, if part of the dwelling unit. , Sectio 105 (a). / Jf) ç; L (5 ii ,4e I 7 When sleeping rooms are upstairs, at the /8. R'equired windows hall not open into a robfed upper level in close proximity to the porch unless the ceiling height is at least 7 stair. feet, the longer side is at least 65% open, In rooms adjacent to hallways serving and the porch abuts a street, yard or court. bedrooms, when such rooms have a ceiling Section 1205 (a). height 24 inches or more above the ceiling height in the hallway. 11Y. Provide mechanical ventilation capable of NOTE: Detectors shall sound an alarm audible 7 providing five air changes per hour in in jj sleeping areas of the unit. Section bathrooms, water closet compartments, laundry 0. 121 rooms and similar rooms if required openable windows are not provided. Section 1205 (c). 2,0. When the valuation of a room addition or / repair exceeds $1,000, or when sleeping rooms ) Note that the discharge point for exhaust air are created, smoke detectors shall be provided / will be at least 3 feet from any opening into at existing bedrooms per item 19 above, the building. Section 1205(c). Section 1210. / 1. Ductless fans cannot be used in bathrooms if a _______ GENERAL IDTIAL RBuixr2TS / tub or shower is present. Section 1205(c). Habitable rooms, other than kitchens, shall Show that ceiling height for habitable rooms is 7'611. Section 1207 (a). a minimum of contain at least 70 feet floor square of area. / At least one room shall have not less than 120 square feet of floor area. Section 1207 (b). 33v Show ceiling height for laundry rooms, No habitable room, other than a kitchen, shall hallways, corridors, and bathrooms is a minimum of 71 0". Section 1207 (a). be less than 710" in any dimension. Section 1207 (c). $. Dimension on the plans 30" clear width for / water closet compartments and 24" clearance in front of water closet. Section 511 (a). 5/22/92 3 35 Show safety glazing in the following Provide 36" high protective railing for G balconies, and open sides of stair ations, per Section 5406(d): porches, Where the nearest edge of glazing is landings. Openings between railings shall be within a 24-inch are of either side of a -less than 4". The triangular openings formed _..mow" door in a closed position (unless there is by the riser, tread and bottom elements of a an intervening wall between the door and the glazing or if the glazing is 5'-O" or guardrail at a stair shall be less than 6". Section 7l2. higher above the walking surface). ki e.c< Glazing greater than 9 square feet with ,43. Show how gua'drail connection details are lineal foot the bottom edge less than 18" above the Z adequate to support 20 pounds per floor and the top edge greater than 36" at a right angle to the top rail. Table 23-B. above the floor (unless the glazing is more than 36" horizontally away from j4. Provide stairway and landing details. Section walking surfaces or if a complying 3306 (b), (c) and (o). protective bar is installed). C. Glazing in shower and tub enclosures Maximum rise is 7" and minimum run is (including windows within 5 feet of tub 1111 . When the stairs serves less than 10 or shower floor.), - occupants, or serves an unoccupied roof, rise may be 8" maximum and run 9" PUW / /t". iUt vi /i.-t 3. Walls and floors separating units in a duplex minimum. / shall be of one-hour fire-resistive construction. Provide details of the Minimum headroom is 61 -811. assemblies. Section 1202(b). C. Minimum width is 36". 3x A mezzanine is an intermediate floor and may / not have a floor area exceeding 33 1/3 percent 4,5< All handrails per Section 3306 (i), shall of the total floor area in the room below. The / satisfy the following: mezzanine floor must have a clear height of 7 feet, above and below, and must have the long Provide handrail for stairways with 4 or side open to the room below except for posts more risers. and protective walls or railings not exceeding 44" in height. Section 1717. Handrails and handrail extensions shall be 34" to 38" above the nosing of treads. 37 The loft you show does not comply as a / mezzanine floor and is, by Uniform Building C. The handgrip portion of handrail shall be Code definition, a story. Section 1717. not less than 1 1/211, nor more than 2" in cross-sectional dimension. 39 Dwellings used for daycare for 7 to 12 children / shall comply with the special requirements in d. Except for stairs serving only one Chapter iz of Title 24. tenant, handrails shall be extended 12" beyond the top and bottom of the stair. lTS, STAI1JAYS. AND RAILINGS 6. Every stairway landing shall have a 4ft' Floors above the second story shall have not / dimension, measured in the direction of / less than 2 exits. Exceptions: 1. Occupied travel, at least equal to the stairway width. roofs may have one exit if such occupied areas If a door occurs at the landing, such are less than 500 square feet and located no dimension need not exceed 36 inches. Section higher than immediately above the second story. 3306 (g), 3304 (j). 2. When the third floor within a unit does not exceed 500 sq. ft., only one exit need be }c1. An interior door may open at a landing that is provided. Section 3303(a). not more than 8" lower than the floor level, provided the door does not swing over the Al. Required exit doorways shall be not less than landing. Section 3304(i). 7 36" in width and not less than 618" in height. j( Provide details of winding stairway complying / with Section 3306 (d): Minimum tread is 6 inches at any point and minimum 9 inches at a point 12 inches from where the treads are narrowest. Maximum rise is 8 inches. C. Minimum width is 36 inches. 9/2/9 49 Pró'ide spiral stairway details, per Section 3306 (f): Minimum run is 7 1/2 inches measured at a point 12 inches from where the treads are the narrowest. Maximum rise is 9 1/2 inches. Maximum clear opening between risers is 6 inches. C. Minimum headroom is 6 feet 8 inches d. The tread must provide a clear walking area measuring at least 26 inches from the outer edge of the supporting column-to the inner edge of the handrail. Spiral stairways may not be used for required exits when the area served is greater than 400 sq. ft. Section 3306 (f). - 5/ Provide I.C.B.0. Research Report and number for / metal stairway, or submit plans and calculations and approved fabricator registered with the building department or note that the stairway fabrication plans shall be submitted to and approved by the building official prior to installation. Exterior stairways shall not project into the 3 foot setback from the property lines. Section 3306 (m). 5 The walls and soffits of the enclosed usable / space under interior stairs shall be protected - on the enclosed side as required for one-hour fire-resistive construction. Section 3306 (1). Within units, show that corridors have a / minimum width of 36 inches. Section 3305 (b). ROOFPG Specify roof slope. . Roof slope is not adequate for roof type / specified. Table 32-B, D and E. Specify roof material and application. Chapter 32. ,1. Specify I.C.B.0. or U.L. approval number for / roof materials not covered in U.B.C., e.g., tile, etc. Section 107. 59 Specify minimum 1/4 inch per foot roof slope 7 for drainage or -design to support accumulated water. Section 3207 (a) and Section 2305 (f). Show roof drains and overflows. Section 3207. 61 Provide skylight details to show compliance with Sections 3401 and 5207 or provide I.C.B.0. approval number. Plastic skylights must be separated from each other by at least 4 feet, unless they are over the sane room and their combined area does not exceed 100 square feet (or 200 square feet if the plastic is a "CCI" material). Section 5207 (a) 6. /3. Show attic ventilation. Minimum vent area is 1/150 of attic area or 1/300 of attic area if at least 50 of the required vent is at least 3 feet above eave vents or cornice vents. Show required area and area provided. Section 3205 (c). ,64. Provide fireplace construction details or note construction to be per attached fireplace standard drawing. Chapter 37. 65. Show anchored veneer support and connections attached to wood in Seismic Zones 3 and 4, comply with Section 3006 (d)1 and Section 2515 (a). Show ties, #9 wire in horizontal joints, etc. 66 Show height and construction details of all concrete and masonry walls. Chapters 24 and 26. Show floor and roof connections to masonry and concrete walls. Connection shall resist 200 pounds per lineal foot or the actual design load, whichever is greater. Cross grain tension or bending in wood ledgers is not permitted. Section 2310. Show a minimum 2" air space and flashing - between planter and building walls. Section 2516 (c) 7. GARAGE MW CARS 69< Garage requires one-hour fire protection on the garage side of walls and ceiling coimon to the dwelling. Table 5-B, Section 503- (d). /761 All elements supporting floor above garage, including walls supporting floor joists, must have one-hour fire-resistive protection on the garage side. Section 503 (b) 7X Show a self-closing door, either 1-3/8" solid core or a listed 20-minute assembly, for openings between garage and dwelling. Section 503 (d). 5/22/92 5 72/ Garages are not permitted to open into a room / used for sleeping purposes. Section 1104. An occupancy separation is not required between carport and residence, provided the carport is open on two or more sides and has no enclosed uses above. Section 503 (a) Exception 3. 7/ Show garage framing sections, size of header / over garage opening, lateral cross bracing at plate line, method bracing garage front and holddowns if required. Chapter 23. NOTE: Maximum shear panel height-to-width ratio is 3 1/2 to 1 for plywood. Table 25-I. Doors may open into the garage only if the / floor or landing in the garage is not more than one inch lower than the door threshold. Section 3304 (i). Provide an 18" raised platform for any FATJ, / water heater, or other device in the garage which may generate a flame or spark. UHC Section 508, UPC Section 1310 (a). 1"s yall.%omm Per soils report, note on the plan the soils / classification, whether or not the soil is expansive and the allowable bearing value. Section 2905 (c). The foundation plan does not comply with the /1 soils report recommendations for this project. Please review the report and modify design, notes and details as required to show compliance:___________________________________ /9. Provide notes on the foundation plan listing / the soils report recommendation for foundations, slab and building pad preparation. 46. The soils engineer recommended that he/she / review the foundation excavations. Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that: - The building pad was prepared in accordance with the soils report, The utility trenches have been properly backfilled and compacted, and The foundation excavations comply with the intent of the soils report". / -81. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (when required by the soil report). 82/ Show height of all foundation walls. Chapter / 23. ,81. Show height of retained earth on all foundation walls. Chapter 23. If cut or fill slopes exist, show distance from foundation to edge of cut or fill slopes and show steepness and heights of cuts and fills. Chapter 29. 85. Note on plans that wood shall be 6" minimum above finish grade. Section 2907 (a). / ,86. Note on plans that surface water will drain away from building and show drainage pattern and key elevations. Section 2905 (f). 87. Dimension foundation per U.B.C. Table 29A: Floors Footing Supported Stenwall Width Depth Thickness 1 6" 12" 12" 6" 2 8" 15" 18" 7" 3 10" 18" 24" 8" Foundations may support a roof in addition to the floors. Where only a roof is supported, use foundation for one floor. ,88. Show foundation sills to be pressure treated, / or equal. Section 2516 (c) 3. 89' Show foundation bolt size and spacing. / Section 2907 (f). Specify size, I.C.B.O. number and manufacturer / of power driven pins and expansion anchors. Show edge, end distances and spacing. Section 302 (d). If required, show size, embedment and location / of hold down anchors on foundation plan. Section 302 (d). If hold downs are required, note on plan that hold down anchors must be tied in place prior to foundation inspection. Section 305 (e) 1. Show adequate footings under all bearing walls and shear walls. Section 2907 (b). 5/22/92 6 94/ Show on the plans stepped footings for slopes / steeper than 1:10. Section 2907 (c) Show minimum 18" clearance from grade to bottom of floor joists and minimum 12" clearance to bottom of girders. Section 2516 (c) 2. 6. Show pier size, spacing and depth into / undisturbed soil. Table 29-A. 92. Show minimum underfloor access of 18" x 24". 7 Section 2516 (c)2. - Show minimum underfloor ventilation equal to 1 sq. ft. for each 150 sq. ft. of underfloor area. Openings shall be as close to corners as practicable and shall provide cross ventilation on at least two approximately opposite sides. Section 2516 (c) 6. ,99. Show wall bracing. Every exterior wood stud / wall and main cross-stud partition shall be braced at each end at least every 25 feet of length with 1 x 4 diagonal let-in braces or equivalent. Section 2517 (g) 3, Table 25-V. ióo. In 2-story buildings, shear panels at the first story (at least 48 inches in width) shall be located at each end or as near thereto as possible and comprise at least 25 percent of the linear length of the wall, or provide design. Section 2517(g)3, Table 25-V. 101. Note cross bridging or blocking. Floor joists and rafters 12" or more in depth shall be 7 supported laterally by bridging at intervals not exceeding 8 feet, unless both edges are held inline. Sec. 2506 (h). 10. Show blocking at ends and at supports of floor / joists, rafters and trusses at exterior walls. Section 2517 (d) 3, 2517 (h) 7. T- Bearing partitions, perpendicular to joists, shall not be offset from supporting girders, beams, walls or partitions, more than the depth / of the joist. Section 2517 (d) 5. Show rafter ties. Rafter ties shall be spaced not more than 4 feet on center and be just above the ceiling joists, where rafters and ceiling joists are not parallel. Section 2517 (h) 5. 5. Show rafter purlin braces to be not less than 45 degrees to the horizontal. Section 2517 (h) 6. 3,66. Show double top plate with minimum 48" lap 7 splice. Section 2517 (g) 2. 1,07. Show nailing will be in compliance with Table 25-Q. 108. Show or note fire blocks at the following / locations per Section 2516 (f): In concealed spaces of stud walls and partitions, including furred spaces, at the ceiling and floor levels and at 10 foot intervals both vertical and horizontal; At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings; C. In concealed spaces between stair stringers at the top and bottom of the run and between studs along and inline with the run of stairs if the walls under the stairs are unfinished; In openings around vents, pipes, ducts, chimneys, fireplaces and similar openings which afford a passage for fire at ceiling and floor levels, with noncombustible materials; and At openings between attic spaces and chimney chases for factory-built chimneys. iA. In duplexes, draft stops shall be provided in floor-ceiling assemblies and attics in line with walls separating units and separating units from common areas. Section 2516(f)4. / 110. Show stud size and spacing. Maximum allowable stud heights: Bearing wall: 2 x4 and 2 x 6 max. 10'; Non-bearing: 2 x 4 max. 141 , 2 x 6 max. 201. Table 25-R-3. I'll. Studs supporting two floors, a roof and ceiling must be 3 x 4 or 2 x 6 at -16" o.c. Table 25-R-3. 112. Note on A.I.T.C. Certificate of Compliance for glued laminated wood members shall be given to the building inspector prior to installation. Section 2505. Detail all post-to-beam and post-to-footing / connections and reference the detail to the plan. Section 2516 (ix). ll'. Detail shear transfer connections, including roof and floor diaphragms, to shear walls. Section 2513. 5/22/92 7 115/ Specify nail size and spacing for all shear / walls, floor and roof diaphragms. Indicate / required blocking. Maintain maximum diaphragm dimension ratios. (Tables 25 I, 3, IC and Section 4714 (d)]. 1 , 94. Provide truss details and truss calculations for this project. Specify truss identification numbers on the plans. 17. Show 1/2" minimum clearance between top plate / of interior partitions and bottom chord of trusses. (To ensure loading will be as designed). i8. Provide roof framing plan and floor framing / plan. Section 302 (d). / 119. Provide framing sections through Section 302 (d). iO. Specify all header sizes for opening over 4' / wide. Section 2517 (g) 5. Provide calculations for main vertical and / horizontal framing members and post footings. / Section 302 (b). Provide calculations for lateral loads, shear panels, shear transfer and related. Section 302 (b). 12. In Seismic Zones 3 and 4, the allowable shear / wall values for drywall in Table 47-I must be reduced 50 percent when considering earthquake loads. This does not apply to wind loads. Footnote 1. 114. Show on the plans all structural requirements / developed in the structural calculations. Section 302 (d). (See comments below or at end.) 1'5. Columns and posts located on concrete or / masonry floors or decks exposed to the weather or to water splash or in basements and which support permanent structures shall be supported by concrete piers or metal pedestals projecting above floors unless approved wood of natural resistance to decay or treated wood is used. Section 2516 (c) 4. Individual concrete or masonry piers shall / project at least 8 inches above exposed ground / unless the columns or posts which they support are of approved wood of natural resistance to decay or treated wood is used. Section 2516 (c) 4. -127. Show location of attic access with a minimum size of 22"x30", unless the maximum vertical headroom height in the attic is less than 30". Access must be provided to each separated attic area, shall be located in a hallway or other readily accessible location and 30" headroom clearance is required above the opening. Section 3205(a). /28. Show location of attic access with minimum size 2211,x 30". Section 3205. A. Detail truss layout for 30" x 30" attic / access, if required for equipment in the attic, and detail 30" x 30" clearance through truss webs. Specify plywood and/or particle board / thickness, grade and panel span rating. Table 25-S. 1I1. Show plywood sheathing over exposed saves, or / other weather exposed areas, is "bonded with exterior glue." Plywood used for exterior wall covering shall be the exterior type. Section 2516 (i), 2516(g)3. When roof pitch is less than 3:12, design / ridge as a beam. Section 2517 (h). )13. Ridges, hips, and valleys shall be at least one size larger than supported rafters. Section 2517 (h) 3. In open beam construction, provide strap ties / across the beams at the ridge support. Section 2501 (b). ,35. If foundation cripple wall studs are less than 14" high, framing shall be solid blocking, or sheathed with plywood. Section 2517 (g) 4. Cripple wall studs exceeding 4 feet in height / shall be 3 inch by 4 inch or 2 inches by 6 inches when supporting 2 stories. Section 2517 (g) 4. Note on the plans that "all weather-exposed / surfaces shall have a weather-resistive barrier to protect the interior wall covering and that exterior openings shall be flashed in such a manner as to make them weatherproof". Section 1708. MECHANICAL (UNIFORM MEANICAL (X)DE) All heating, ventilating, and cooling systems and appliances shall comply with the Uniform Mechanical Code. 5/22/92 8 138.--Show. the .size, location and type of all heating and cooling appliances or systems. Every dwelling unit shall be provided with heating facilities capable of maintaining a room temperature of 70 degrees F. at 3 feet above the floor in all habitable rooms. Show basis for compliance. UBC, Sec. 1212. 140'. Note on the plans that the FAIJ closet or / alcove must be 12 inches wider than the furnace or furnaces being installed. UMC Section 704. - Show minimum 30t deep unobstructed working /7 space in front of furnace. Section 505, UMC. 12. Furnace shall not be installed in any bedroom, / bathroom or in a closet or confined space with access only through such room unless specified as direct vent appliance, enclosed furnace or electric heating appliance. Section 704 UMC. I 4. Show source of combustion air to furnace, per / Chapter 6, UMC. Show access to the attic containing equipment / to be minimum 30 inches by 30 inches. The opening may be 22 inches by 30 inches if the equipment can be removed through such opening.' Section 708 UMC. 15. Note that passageway to the attic furnace / shall be unobstructed and have continuous solid flooring not less than 24 inches wide, not more than 20 feet in length through the attic. Section 708 UMC. Show permanent electrical outlet and lighting / fixture controlled by a switch for furnace located in attic or underfloor space. Section 708 & 709 UMC. Show details to comply with Section 709 for / furnace under the floor, or Section 710 for roof or outside furnace. Show I.C.B.0. approval number for prefab ./ fireplace. Show height of chimney above roof per I.C.B.0. approval or Table 37-B. / 1,51. Provide dryer vent to outside. UMC, Section ,, 1903. ELxIcAL (NATIONAL ELE=CAL CODE) All wiring shall comply with the National Electrical Code. 152. Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub- panels. If service is over 200 amps, submit single line diagram, panel schedule and load calculations. l3. Show on the plan that receptacle outlets 7 comply with 1990 NEC Art. 210-52(a), which reads as follows: In every kitchen, dining room, parlor, library, den, sunroom, bedroom, recreation room, or similar rooms or area of dwelling units, receptacle outlets shall be installed so that no point along the floor line in any wall space is more than 6 feet, measured horizontally, from an outlet in that space, including any wall space 2 feet or more in width and the wall space occupied by fixed panels in exterior walls, but excluding sliding panels in exterior walls. The wall space fforded by fixed room dividers, such as free-standing bar-type counters, shall be included in the 6-foot measurement. Dwelling Unit Receptacle Outlets 210-52(e) I LJ' 1 - e- - Sliding Panels or Doors - .91 I -___ L. 149. Note on the plans that approved spark arrestors shall be installed on all chimneys. Section 3703(h) l0. Note on plan: Gas vents and non-combustible / piping, in walls, passing through three floors or less shall be effectively draft stopped at each floor or ceiling. UBC, Section 1706 (c). 8/5/92 9 j5I Show on the plan that countertop receptacle / outlets comply with 1990 NEC Art. 210-52(c), / which reads as follows: In kitchens and dining areas of dwelling units a receptacle outlet shall be installed at each counter space wider than 12 inches. Receptacles shall be installed so that no point along the wall line is more than 26 inches measured horizontally from a receptacle outlet in that space. Island and peninsular countertops 12 inches or wider shall have at least one receptacle for each four feet of counter top. Counter top spaces separated by range tops, refrigerators, or sinks shall be considered as separate counter top spaces. Receptacles rendered inaccessible by appliances fastened in place or appliances occupying dedicated space shall not be considered as these required outlets. Dwelling Unit Receptacle Outlets Counter Tops 210.52(c) F --2--1 i-2-+-2'H —a 0 o o 0 - 4 Re GF GFt -re 2 .1. - 10chen0r - Dining Area C, 155. Show on the plan that receptacle outlets in / hallways comply with 1990 NEC Art. 210-52(h), / which reads as follows: For hallways of 10 feet or more in length at least one receptacle outlet shall be required. As used in this subsection the hail length shall be considered the length along the centerline of the hail without passing through a doorway. Dwelling Unit Receptacle Outlets Hallways 210.52(h) BR Levi K DR E— BR e.çS Sit I I c u'I 15E. Show on the plan that lighting outlets in dwelling units comply with 1990 NEC Art. 210- 70(a) and (c), which read as follows: (a) Dwelling Unit(s). At least one wall switch-controlled lighting outlet shall be installed in every habitable room; in bathrooms, hallways, stairways, attached garages, and detached garages with electric power; and at outdoor entrances or exits. (FPN): A vehicle door in an attached garage is not considered as an outdoor entrance. At least one lighting outlet controlled by a -light switch located at the point of entry to the attic, underfloor space, utility room, and basement shall be installed only where these spaces are used for storage or contain equipment requiring servicing. The lighting outlet shall be provided at or near the equipment requiring servicing. Where lighting outlets are installed according to (a) above in interior stairways, there shall be a wall switch at each floor level to control the lighting outlet where the difference between floor levels is six steps or more. Exception No. 1: In habitable rooms, o ther than kitchens and bathrooms, or more receptacles controlled by a wall switch shall be permitted in lieu of lighting outlets. Exception No. 2: In hallways, stairways, and at outdoor entrances remote, central, or automatic control of lighting shall be permitted. 8/6/92 10 (c) Other Locations. At least one wall switch- controlled lighting outlet shall be installed at or near heating, air-conditioning, and refrigeration equipment in attics or underfloor spaces. The light switch shall be located at the point of entry to the attic or underfloor space. 157. Show on the plan that ground-fault circuit- interrupter protection complies with 1990 NEC Art. 210-8, which reads as follows: (a) Dwelling Units. All 125-volt, s1ng1e-phase, 15- and 20- ampere receptacles installed in bathrooms shall have ground-fault circuit-interrupter protection for personnel. All 125-volt, single-phase, 15- or 20- ampere receptacles installed in garages shall have ground-fault circuit-interrupter protection for personnel. Exception No. 1 to (a)(2): Receptacles which are not readily accessible. Exception No. 2 to (a)(2): Receptacles for appliances occupying dedicated space which are cord- and plug-connected in accordance with Section 400-7(a)(6), (a)(7), or (a)(8). Receptacles installed under Exceptions to Section 210-8(a)(2) shall not be consideed as meeting the requirements of Section 210-52(g). All 125-volt, single-phase, 15- and 20- ampere receptacles installed outdoors where there is direct grade level access to the dwelling unit and to the receptacles shall have ground-fault circuit-interrupter protection for personnel. (FPN): See Section 215-9 for feeder protection. For the purposes of this section, "direct grade level access" is defined as being located not more than 6 feet, 6 inches (1.98m) above grade level and being readily accessible. All 125-volt, single-phase, 15- and 20- ampere receptacles installed in crawl spaces at or below grade level and in unfinished basements shall have ground-fault circuit- interrupter protection for personnel. Exception No. 1: A single receptacle supplied by a dedicated branch circuit which is located and identified for specific use by a cord- and plug-connected appliance, such as a refrigerator or freezer. Exception No. 2: The laundry circuit as required by Sections 210-52(f) and 220-4(c). Exception No. 3: A single receptacle supplying a permanently installed sump pump. All 125-volt, single-phase, 15- and 20- ampere receptacles installed within 6 feet of a kitchen sink to serve counter top surfaces shall have ground-fault circuit-interrupter protection for personnel. (FPN): The intent of this subsection is to permit the exemption of receptacles which are located specifically for appliances such as refrigerators and freezers from ground-fault circuit-interrupter protection for personnel. PLUMBING (UNIFORM PLUMBING (X)UE) Show water heater size, type and location on plans. UPC, Section 1301. Note on the plans that "combustion air for fuel burning water heaters will be provided in accordance with the Uniform Plumbing Code". Fuel combustion water heater shall not be installed in clothes closets, in a bath or bedroom, or in a closet opening into bath or bedroom. UPC, Section 1309. Provide adequate barrier to protect water heater from vehicle damage. An 18" platform for the water heater does not satisfy this requirement. UPC, Section 1310. 8/6/92 11 163/ Show T and P valve on water heater and show route of discharge line to exterior. UPC, Section 1007 (e). l. Show that ater heater is adequately braced to / resist seis w mic forces. UPC, Section 1310. 164'. Show shower stall can accommodate a 30" circle / and has a minimum floor area of 1,024 sq. in. UPC 909 (d). $s. Provide clothes washer hook-up for each unit. / Title 24, Part 3. 6. New water closets -and associated flushometer / valves, if any, shall use no more than 1.6 gallons per flush and shall meet performance standards established by the American National Standards Institute Standard A112.19.2, and urinals and associated flushometer valves, if any, shall use no more than one gallon per flush and shall meet performance standards established by the American National Standards Institute Standard A112.19.2. H & S Code, Section 17921.3(b). NOISE INSULATION (DUPLEXES) Show details of duplex common (party) walls / and floor/ceiling assemblies to achieve a Sound Transmission Class (STC) rating in walls of 50 decibels and an Imp4ct Insulation Class (IIC) rating on floor/ceiling of 50 decibels. Title 24. 168'Show how penetrations of assemblies for piping, electrical devices, recessed cabinets, bathtubs, soffits, or heating ventilating, or exhaust ducts shall be sealed, lined, or insulated to maintain required sound transmission rating. Title 24. 169. Provide insulation in walls and ceiling to achieve SIC of 50 between garage and living area if garage use is not controlled by resident. Title 24. ENERGY CONSERVATION )76. Provide plans, calculations and worksheets to show compliance with current energy standards. ,X71. The regulations require a properly completed Z and properly signed Form CF-1R to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design. All energy items shown on the plans must be in / agreement with the information shown on the properly completed Form CF-1R. 43. Specify on the building plans all of the / mandatory energy conservation requirements as listed on the enclosure titled, "Mandatory Energy Conservation Requirements". )7'4. Show the make, model and efficiency of the ./ space heating (or cooling) system and provide heat loss calculations if the output exceeds 45,000 BTU/Hr. For room additions, show that the glazing area / of the addition does not exceed 16% of the / newly-conditioned floor area, plus glazing removed or relocated due to the addition. I,/6. Provide fluorescent general lighting in / kitchen(s) per CAC, Title 24, 2-5352(3). CARLSBAD S .F.D. & DUPLEX SUPPLEMENT ljñ' Energy conservation design should be for Zone /7. Floor drains must have auto-prime (city /7 policy). For gas piping under slabs that serve kitchen / island cooktops, see the attached Policy 91-46 for special sleeve and clean-out requirements. 18 Note exhaust fans cannot be ductless type ,/ (city policy). la<''New residential units must be pre-plumbed for future solar water heating. Note "two roof / jacks must be installed" where the water .7 heater is in the one story garage and directly below the most south facing roof (City Ordinance No. 8093). 182. Note "two 3/4" copper pipes must be installed to the most convenient future solar panel location when the water heater is not in a one story garage and is not directly below the most south facing roof. (City Ordinance No. 8093). l8. All piping for present or future solar water / heating must be insulated when in areas that are not heated or cooled by mechanical means (city policy). l Incorporate the waterproofing details, on the / attached Policy 80-8, where interior living space occurs below grade at the masonry wall(s). 8/11/92 1 185. Show on the Title Sheet on the plans, the information required by the attached Developmental Services Sheet 112383. All new residential buildings, including / additions, require a soils report. Please submit two copies. Exception: If a room addition is limited to one story and 1000 sq. ft. in area, then a soils report is not required. Esgil Corporation will advise the City to place their soils notice stamp on the plans. 1(Heavy timber framing, minimum 6" x 10" beams / and minimum 8" x 8" post, for the structural beam and column supporting the fire separation between the garage and living area above, is acceptable if shown on the plans. (city policy). The City of Carlsbad has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number 619/560-1468, to perform the plan check for your project. If you have any questions regarding these pl Zi7 please con t at Esgil Corporatlo If you have any questions regarding City Building permit procedures, please contact Carter Darnell at the City of Carlsbad, 2075 Las galmAs Dr., telephone 619/438-1161. Thank you. Enclosures: l. All structures require a Class B roof covering, / except room additions. If a room addition covers all of the existing building (2nd story addition), then the above exception doesn't apply. City Ordinance 9792 requires two parking / spaces/unit with clear area of 20'x20' i.e. no washing machines, etc. Show compliance. Only tank-type water closets that use an average of 1.6 gallons of water per flush or less, and urinals and associated flushometer valves, that use an average of 1 gallon of water per flush or less shall be installed in new construction. These provisions shall apply to existing buildings only when toilets are being replaced in existing bathrooms or installed in new bathrooms. Please see additional corrections, or remarks, on the following page. To speed up the recheck process, note on this / list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 193 Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please check. Yes No 8/11/92 13 Date 1L Jurisdiction. CARLSBAD Prepared byi Lkv— VALUATION AND PLAN CHECK FEE E3 Bldg. Dept. El Esgil PLAN CHECK NO. _2_l S BUILDING ADDRS - ____c_ APPLICANT/CONTACT PHONE N. BUILDING OCCUPANCY 3 DESIGNER PHONE______________ TYPE OF CONSTRUCTION (J /\J CONTRACTOR PHONE____________ BUILDING PORTION BUILDING AREA VALUATION MULTIPLIER VALUE O 404-A _1_y1 77J / 0 Air Conditioning Commercial Residential Res. or Comm. Fire _Sprinklers Total Value Buildiri6 Per mit V e e $ - _ L71 9__$_78 - Plan Check Fee $ s < ' COtiMENTS Z/ Z. / ' SHEET / OF / 12/87 0'rzaA/ Lcrr W M/3P iOZ57 i * CA, of Carlsbad BUILDING PLANCHECK CHECKLIST DATE:. 2-9 T 2 PLANCHECK NOc92.' 1-35 BUILDING ADDRESS: 2524, LiC G00t4bR1J4 PROJECT DESCRIPTION: 1E ASSESSOR's PARCEL NUMBER: 2115 - 561 '— 08 EST. VALUE____________ ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. DENIAL Please see the attached report of deficiencies marked with,IS. Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By:! HELELL Date:20ZT2_ By:__ Date:_________ By: Date:_________ ATTACHMENTS O Dedication Application O Dedication Checklist O Improvement Application O Improvement Checklist O Future Improvement Agreement NAME: ADDRESS: CONTACT PERSON PHONE: P:\docs\chk1st\bp0001.lrm REV 6/5/92 2075 Las Palmas Dr. • Carlsbad, CA 92009-1576 • (619) 438-1161 • FAX (619) 438-0894 BUILDING PLANCHECK CHECKLIST SITE PLAN 1 st/ 2ncW 3rdv' DD 1. Provide a fully dimensioned site plan drawn to scale. Show: North Arrow D. Property Lines Easements Existing & Proposed Structures E. Easements Existing Street Improvements F. Right-of-Way Width & Adjacent Streets j1 D 2. Show on site plan: C. Existing Topography B. Existing &Proposed Slopes / LI D 0 3. Show on a section drawing or include a note stating that there is a minimum of 6" difference between the finished floor and the finished grade elevation adjacent to the structure. 0 4. Include note: "Surface water to be directed away from the building foundation at a 2% gradient for no less than 5' or 213 the distance to the property line (whichever is less)." [Per 1985,UBC 2907(d)5]. On graded sites, the top of any exterior foundation shall extend above the elevation of the street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12 inches plus two percent" (per 1990 UBC 2907(d)5.). 0 0 5. Include on title sheet Site address Assessor's Parcel Number Legal Description For commercial/industrial buildings and tenant improvement projects, include: Total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION P:\docs\chk1stbp0001.frm Page 1 of 4 REV 6/5/92 BUILDING PLANCHECK CHECKLIST N/i DISCRETIONARY APPROVAL COMPLIANCE 1 sti/ 2nd./ 3rd./ LJDD 6. Project does not comply with the following Engineering Conditions of approval for Project No. Conditions were complied with by: Date:__________________ NIA DEDICATION REQUIREMENTS O 0 0 7. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $______________ -pursuant to Code Section 18.40.030. Dedication required as follows: Attached please find an application form and submittal checklist for the dedication process. Provide the completed application form and the requirements on the checklist at the time of resubmittal. Dedication completed by Date:___________ IMPROVEMENT REQUIREMENTS O 0 0 8a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ -pursuant to Code Section 18.40.040. Public improvements required as follows: Please have a registered Civil Engineer prepare appropriate improvement plans and submit them together with the requirements on the attached checklist for a separate plancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. Attached please find an application form and submittal checklist for the public improvements requirements. Provide the completed application form and the requirements on the checklist at the time of resubmittal. Improvement Plans signed by: Date: P:\docs\chkl4t\bp0001.frm Page 2 of 4 1 REV 6/5/92 BUILDING PLANCHECK CHECKLIST 1 SW 2nd' 3rd DElEl 8b. Construction of the public improvements may be deferred pursuant to code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $____________________ so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit. Future public improvements required as follows:_______________________________ O El El 8c. Enclosed please find your Future Improvement Agreement. Please return signed and notarized Agreement to the Engineering Department. Future Improvement Agreement completed by: / Date:___________________ 121 0 0 8d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. El 0 El 9a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). El El El 9b. Grading Permit required. A separate grading plan prepared by .a registered Civil Engineer must be Submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: I3I" 0 El 9c. No Grading Permit required. BUILDING PLANCHECK CHECKLIST P:\doc9\chk1st\bpOOO1.frm Page 3 of 4 REV 6/5/92 4 N//- MISCELLANEOUS PERMITS 1 SW 2nd/ 3rdv' 0 0 0 10. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, trees, driveways. A separate Right-of-Way permit issued by the Engineering Department is required for the following: Please complete attached Right-of-Way application form and return to the Engineering Department together with the requirements on the attached Right-of-Way checklist, at the time Of resubmittal. EJ 0 0 11. A SEWER PERMIT is required concurrent with the building permit issuance. The fee is noted in the fees section on the following page. O 0 0 12. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial Waste Permit Application Form and submit for City approval prior to issuance of a Permit. Industrial waste permit accepted by: Date: P:\docs\chklst\bp0001.1rm Page 4 of 4 REV 6/5/92 CALCULATIONS WORKSHEET EDU CALCULATIONS: EDU's: ADT CALCULATIONS: ADT's: t,A/)q FEES REQUIRED: WITHIN CFD: 0 YES (NO BRIDGE & THOROUGHFARE FEE, REDUCED TRAFFIC IMPACT FEE) DNO O 1. PARK-IN-LIEU FEE PARK AREA: FEE/UNIT:_________ O 2.TRAFFIC IMPACT FEE ADT's: FEE/ADT: El 3. BRIDGE AND THOROUGHFARE FEE ADT's: FEE/ADT:____________ FACILITIES MANAGEMENT FEE ZONE: FEE/EDU:_________ PUBLIC FACILITIES FEE Cl 6. SEWER FEES PERMIT No. EDU's: FEE/EDU:_________ BENEFIT AREA: FEE: 0 7. SEWER LATERAL REQUIRED (2,500 DEPOSIT) REMARKS: P:\docs\chklst\bp000l.frm REV 6/5/92 PLANNING CI-IEC}UIST Plan Check No. CBQ2/(5'Address 25Z Lii 60L.O,c1b12./,t/,4 Planner VAN LYNCH Phone 438-1161 ext. 4325 (Name) APN: Type of Project and Use ,e-6f1) 9J77t- 1 bb t 77O M' Zone /2--1 Facilities Management Zone ______________ Legend . - . cl U U 4, 41 41 Item Complete ci ci ci C C C 41 41 Item Incomplete - Needs your action 1, 2, 3 Number in circle indicates plancheck number where deficiency was identified Environmental Review Required: YES - NO 4 TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval Discretionary Action Required: YES - NO 2 TYPE APPROVALJRESO. NO. DATE: PROJECT NO. OTHER RELATED CASES: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval California Coastal Commission Permit Required: YES - NO/ DATE OF APPROVAL: San Diego Coast District, 3111 Camino Del Rio North, Suite 200, San Diego, CA. 92108-1725 (619) 521-8036 Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval Landscape Plan Required: YES NO ___ See attached submittal requirements for landscape plans Site Plaw- M-16"C-3 1. Provide a fully dimensioned site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width and dimensioned setbacks. [1iE] 0 2. Show on Site Plan: Finish floor elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes and driveway. 0 3. Provide legal description of property. 21fI10 4. Provide assessor's parcel number. Zoning: '6o 1. Setbacks: Front: Required Ent. Side: Required Street Side: Required Rear: Required 'Ii [ 0 Lot coverage: Required C!EY'f 0 Height: Required 0 Parking: Spaces Required Guest Spaces Required 0 0 0 Additional Comments 2Z) Shown jyf Shown 7' -Shown /4"LShown +-,gz- ____ Shown <Lk2 Shown 24 2 Shown a_ Shown OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER 11 l.-VN S' DATE /o-Z 7—q PLNCK.FRM