Loading...
HomeMy WebLinkAbout2529 STATE ST; ; CB150446; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 04-23-2015 Residential Permit Permit No: CB150446 Building Inspection Request Line (760) 602-272~ Job Address: Permit Type: Parcel No: Valuation: 2529 STATE ST CBAD RESDNTL 2030543403 $295,759.00 Status: ISSUED Applied: 02/11/2015 Entered By: JMA Occupancy Group: # Dwelling Units: Bedrooms: Sub Type: CONDO Lot#: 3 Constuctlon Typ~ Reference'~_3.0005--.J 1 Structure Type: MF5+ 0 Bathrooms: 0 ~ Orig P~:-PC140~7.......J STATE ST. TOWNHOMES: PHS 2 C~ Plan Approved: 04/23/2015 Issued: 04/23/2015 Inspect Area: Plan Check#: PC150021 Project Tltle: 405 SF 1ST FLR COMMERCIAU1,694 SF LIV/ 476 SF GAR/ 67 SF BALCONY/ 585 SF ROOF DECK Applicant: TAYLOR MORRISON OF CA, LLC STE 1450 100 SPECTRUM DR IRVINE CA 9261~935 949-341-1289 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park In Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BID#2 Fee BID#3 Fee Renewal Fee Add'I Renewal Fee Other Building Fl3e HMP Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee Green Bldg Stands Plan Chk Fee Total Fees: Inspector: NOTICE: Please take NOT E that $1,317.94 $0.00 $922.56 ($500.00) $0.00 $38.45 $6,190.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $3,931.00 FS1 ($3,931.00) $0.00 $12.00 $0.00 I Payments to Date: Owner: Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWA Fee CFO Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing lnlleu Fee Housing Credit Fee Master Drainage Fee Sewer Fee Additional Fees Fire Sprinkler Fees TOTAL PERMIT FEES $23,813.89 Balance Due: FS1 $0.00 $317.00 $4,800.00 $0.00 $5,382.81 $4,968.75 $0.00 $0.00 $0.00 $0.00 $0.00 $210.00 $89.00 $65.38 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00. $23,813.89 $0.00 Clearance: ------ referred to as 'fees/exactions.' You 90 days from the date this permit was Issued to protest Imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth In Government Code Section 66020(a), and file the protest and any other required Information wtth the City Manager for processing In accordance with Carlsbad Municipal Code Section 3.32.030. FaDure to tlmely follow that procedure will bar any subsequent legal actlon to attack, review, set aside, void, or annul their Imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor plannlng, zonlng, grading or other similar appllcatlon processing or service faes In connection with this project. NOR DOES IT APPLY to any Inspection List Permit#: CB150446 \ Type: RESDNTL CONDO STATE ST. TOWNHOMES: PHS 2 C1 405 SF 1ST FLR COMMERCIAU1,694 SF L Date Inspection Item -lns~ctor __ ~ Comments ---- 03/17(2016 89 Final Combo PY AP 03/16/2016 89 Final Combo PY NS 03/16/2016 89 Final Combo RI PM PLEASE COF 11/19/2015 39 Final Electrical PY PA 10/08/2015 17 Interior La~rywall PY AP 10/07/2015 17 Interior Lath/Drywall PY AP 10/07/2015 23 Gas/T est/Repal rs PY AP 10/01/2015 84 Rough Combo PY AP 09/29/2015 84 Rough Combo PB CA 09/14/2015 13 Shear Panels/HD's PY AP 09/11/2015 15 Roof/Re roof PY AP 09/01/2015 17 · Interior Lath/Drywall PY PA 08/27/2015 17 Interior Lath/Drywall PY PA 08/21/2015 15 Roof/Reroof PB AP 08/05/2015 17 Interior Lath/Drywall PY PA 06/25/2015 11 Ftg/Foundation/Plers PB AP . 06/04/2015 21 Underground/Under Floor PY AP 06/04/2015 22 Sewer/Water Service PY AP Tuesday, March 22, 2016, Page 1 of 1 .~~ '\;"CITY or CB150446 2529 STATE ST STATE ST. TOWNHOMES: PHS 2 C1 CARLSBAD ~. •lldlng Olvtslon INSPECTION RECORD 405 SF 1ST FLR COMMERC:IAU1,694 SF UV/ 47n SF GAR/ 67 SF BALCONY/ 585 SF ROOF DECK ·.,,_.·INSPECTION RECORD CARD WITH APPROVED PlANS MUST BE KEPT ON nfE .JOB RESDNTI... CONDO Lot#: 3 TAYLOR MORRISON OF CA, LLC @ CALL BEFORE 3;30 pm FOR NEXT WORK DAY INSPECTION @ FOR BUILDING INSPECTION CALL: 76()..602,,;2725 RECORD COPY Required Prior to Requesting Building Final If Checked YES Planning/landscape AION48h<x#S CM&J (Englneerlng lmpectlot1S) 76<>-438-3891 caJI before 2 pm 760-602-4660 AIICNi 48 hour$ Type of Inspection COD!::; ·ELECTRICAL.,'' . . .. Date Inspector 131 0 El.£CTRICUNDERGROUND O UFER 1'34 ROUGH B.EC11UC ~ MASONRY PRE QROUT 1133 0 El.ECTIIIC SERVICE O TEMPORARY ,...._.. OGROUT D WALL DRAINS 135 PHOTO VOLTAIC HO TILT PANELS #11 POUR STRIPS coo~ r. . MECHANICAL · ·. H1 COLUMN FOOTifCGS *41 UNDERGROUND DUCTS & PIPING #14 SUBFRAME O R.OOR O CEfUJIG D DUCT & PlBIUM D REF. PIPING #15 ROOF SHEATHING HEAT-AIR CON D. SYSTEMS lf13 EXT. SHEAR PANW 111.6 INSULATION ·cl'lott:• ·coMBO INSPECTION. · : · #18 EXTERIOR I.Alli #81 UNDERGROUND (11,12,2 l) #17 IHmlOR LAIB & DRYWALL. 1182 DRVWAU.EXT lAlH, GAS TES (17,18,23) #51 POOLEXCA/ BOND/FENCE #55 PREPLASTIR/ FINAL r #21 UNDERGROUND OWASTE O Wilt #24 TOP OUT D WASTE D WTII #27 TUB & SHOWER PAN GAS TEST D QAS PIPING HEAml F AROUGff.JH . F/ARRAL f603 FOUOW UP JHSPECTJON FIXED EXTINGUISHINO SYSTEM ROUGH-IN #605 NOTICE TO CLEAN FIXED EXTINCJ SYSTEM HYDROSTATIC TEST #607 WRITTEN WARNING FlX£D EXTINGUISHING SYSTEM AHAL B609 NOTICE OFVIOLATION MEDICAL GAS PRESSURE TEST #610 VERBAL WARNING MEDICAL GAS AHAL REVl0l2012 SEE !!ACK FOR Bf'eCW. NOTES .. -r,""1~,~-.. -----------------------------:------------------------------------------- LT(s., Z- /I 7 Ccityof · Carlsbad_ CIRCUIT CARD 8~6 Development Services Building Division 1635 Faraday Avenue . 760-602-2719 . www.carlsbadca.gov THIS c.uD MUST BB FILLED OUT AND AV AILABLB AT THE SERVICE RnUJPMI!NT POR THE ROUGH INSPECTION Address: .2S' l °J ~ hrt.r ,1'Htttu-r r-...M w &II (), (\,d 9 J..-¥ Permit Number: u l.f11 "/'It OWner. 4"'-4~ ..:-~H • .,.; Phone: f9'/'I J .J-C// -It,~ o Area In Sq. A. ~o,, Contractor..~ CJ.I 11..lbJ(!!y-?lfl!A~e. Phone: (D/9 579 G,~&) PANEL: G--4~ lo. o~~ A.LC. LOCATION CKT BKR WIRE MISC REC SIZE SIZE TYPE /< /Tcl./E,i 1 ~Q ,,. c.v 4 IJ>t /(! ,eo 3 ::LO /2.. cu r B,+r>l-.5 5 -;;t. 0 12 CV I'S Jc',~ 7 'Z (J ,,_ C...\) LI IFu"l! 9. /5 it/ cu L ~~£ 11 IS tt/ <:.v 3 ;i;tsP~ 13 · /r:;' (9 CV l ~tt:,A$.J.J 15 I> t'I-cu I Giv~V~ '~l; / '5 l 'f <<.J 2 Lf ., AS -J}lfllf 19 /-s' ( 'I c.u ? /)IN/N(r-21 .:l-C /2... -CU '1 23 25 27 29 31 33 36 37 39 41 MAIN: 0 /':~ AMP BRK/FUSE [B' MLO BUS: L~~ AMP A) Size: No. .;:l.. 0 8) Type: M.cu O AL Service entrance or feeder rE': · C) IMulatlon: S D) Conduit size: __ Service ground/bond: L .r-,( A) Size: No. 3 0 B) Type: ~ cu O AL i Clamp !ocatlon(s): UFER 250 -50(c) Water Pipe 250 -104 D Ground Rod 250 -52 D------:c--G~l.locallona 210-8, 680-70: 'gJ Bathroom(s) J:l Kitchen J.Garage(s) OHydromassage Tub Outdoors · D ____ _ 8 Protected Clrc. t~ -12 . p-Bedroom(s) pg.. E.u ff!-'{ I.,.> 1-t!f?..E -:;._'-I~ VOLTS 7 0 "2,.. WIRE REC LTG MISC WIRE BKR SIZE TYPE SIZE CKT LOCATION f)EJ )/ ID C.\) ~5 2 Ale.. 2-4. iov . 10 cu . .,;2.5 4 A-Jc Ot:' D/ I :;;_. C.() .2C e MIN( :;,:J-c. 'O\/ I;)-cV ;:LtJ 8 Sfic.1T I :i qJ ;to 10 e,...!MH-/E~ j /;L c.l) 2.{) 12 F=A-Lf '7 -7 ; l'-1 CV /5 14 P5 D tr. iltf1,-. In '-f I l'-i GtJ ,s 16 ~~E/r( ,~ l 'I C IS-18 /;,l"'e/ /i;Nt r: ~ ' I i'f' c.u /5" 20 M 11JEI-' , ... < 5 'f 2-, /'-/ c.v IS" 22 L.L V ( '11 l!s >oq-1 24 26 26 30 32 34 36 38 I 40 42 Computed Load 7 l./ • (., '.3 AMPS See CaJoulBtlon WorlwlHl on beck Branch circuits required: A) Lighting Circuits 220 -3(b), 4{d) B) Two small Appliance Circuits 21 o -11 (e) C) Laundry Clrcult 220-16(b) D) Central Heating Equipment 422 -12 E) Bathroom 210 -52(d) Remarks: _____________ _ I certlfy that aH termJnations have been torqued In accorrJance wfth manufB:Ctllrer's /nstrUct/ons and that the work shown on this circuit card represents the full extent of the work perfonn&d under th/a permit. • D OWner -~~---..-,,---.....-:::-:::--:-__,=-:o.--,~ ~l~~~~U:: $ eci~t14 Ni,~ Paae 1 of 2 Rev. 03/09 C) ' / 2 ~ -.... ~ •t'"~~ ·--' SINGLE FAMILY DWELLING ELECTRICAL SERVICE LOAD CALCULATION . As an altematlve method, the STANDARD METHOD found In ARTICLE 220 of the National Electric C<x!6, may be uS9d 1. GENERAL LIGHTING LOADS DweU.ing .::l. 1 I I 7 sq. ft. x 3, VA = 220-3(a) t, I 53 / VA small appllan~ loads ..... 220-16(a) 1600 VA x 1 circuits= 3. ooo VA Laundry loaq -220-16(b) 150,0 VA x circuits = ( ; S PO VA Gen~ral lighting Total I 11 o 3 / VA 2. ·coOKJNG EQUIPMENT LOADS -Nameplate Value Range . _... VA = Cooktop VA= .oven (s) VA= __ ----__ VA ---==--VA _____ VA Cooking Equipment Total ____ VA 3. ELECTRIC DRYER 220-18 (Nameplate, 6000 VA minimum) , O~er . . ·r-VA=,. Dryer,Total. _ _.._ __ VA 4. , F[XEJ) APPLIANCE LOADS 230-30 (b) (3) Dishwasher = . D,l~pgsal = Compactor= Water Heater = , Hydromassage Bathtub = Microwave Oven·= Bunt.;,1;, Vacuum = 5. O_PTIONAL SUBTOTAL (Add all of the above totals) 6. _APPL '(ING DEMAND FACTORS-TABLE 220-30 First 10,000,VAx 100% = , Optional Subtotal (from line 5) { R~lnlng Ai 171tl VAx40%• V , 7. HEATIN(3 OR AC LOAD -TABLE 220-30 Lar:g.er of the He~tlng or AC Load.= I, S-00 VA 7S0 VA ____ VA, ____ VA __,,_,,___,..._VA /,:-c,o VA ____ VA ____ VA Fixed Appliance Total ~, 750-vA /<i, 7§/ VA I 10,000 VA 111'1.. VA ~,o~o VA 8. OPTIONAL LOADS TOT AL (Add totals from lines 6 and 7) = l1i'tl~ VA 9. MINIMUM S~RVICE SIZE = Optional ,Loads Jotal • 74, Cc 3 An:ipere --. 240Volt (Please put total on front of card under Computed Load) ' . •,'. ' : ~· .. ,•, ..i.. .. ~ . .~ ' ' " . ' .. C,mtlml/111s lns1iectio11 & Mai,·rhtls TNriff.~ SOUTHWEST ~~~~-~·~~~~.~~~4~~ Inspc:ction & Testing, Inc. 441 Comn~cial Way, La Habra. CA 90631-6168 (5()2).941-2990•(714) 526-8441 FAX (562) 946-0026 October 12, 2015 Building Official Cfty of Carlsbad Department of Building and Safety 1635 Faraday Ave Car:lsbad, California 92008 SPECIAL I°NSPECTOR'S FINAL PROJECT REPORT Project Name: Seagrove townhomes Address: Owner: state street, PH 2 Building 4 Taylor Morrison Unit# Address 1 2521 State Street 2 2525 .State S.treet 3 2529'State Street 4 2533 State Street 5 253 7 State Street Permit CB1504i38 CB150442 CB150446 CB150447 CB150448 Unit# Address 6 2541 State Street 7 2545 state Street 8 2549 state Street 9 2553 State Street Permit CB150449 CB150450 CB150451 CB150452 This Is to certify that Southwest Ir1spectlon and Testing, Inc. was employed to perform special Inspection on the above mentioned· project at the above address, which required continuous Inspection per section 1701 of 2013 California Building Code. Brett Albliriger -Reinforced Concr-ete, Post Tensioned Concrete, SD #656 William Bowen -Reinforced Concrete, Post Tensioned Concrete, Sb #541 Tom Woods-Reinforced Concrete, Post Tensioned Concrete, SD # 377 Based upon special inspection and materials testing written reports of this work, it is our judgment that the Inspected work wa.s perform'ed to the best of our knowledge, In accordance with the approved plans, speclflcatlons and qpplicable workmanship provision o · -· nia Building Code . Reviewed By: Ian R. Waddel Principal Engin r o . WAD.