HomeMy WebLinkAbout2530 Glasgow Dr; ; CBRA2017-0009; PermitPermit
Print Date: 09/12/2018
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
Description:
Applicant:
MIKE STEFFEN
2530 Glasgow Dr
BLDG-Associated Permit Residentia
2081910800
$789,946.21
5.00
THE BLUFFS
Work Class:
Lot#:
Reference#:
Construction Type:
Bathrooms:
Orig. Plan Check #:
Plan Check#:
Single Family Detached
42
DEV2016-0071
VB
5.50
PC150074
PC2017-0003
Status:
Applied:
Issued:
Permit
Fina led:
Inspector:
Final
Inspection:
THE BLUFFS: PHASE 7 // LOT 42 // PlAN 4 // 4,995 SF //648 SF GARAGE /I 248 SF CA ROOM
Owner: Contractor:
RANCHO COSTERA LLC • 2483-INACTIVE TOLL BROS INC
(city of
Carlsbad
Permit No: CBRA2017·0009
Closed· Finaled
01/12/2017
01/03/2018
CRenf
9/12/2018 4:01:03PM
725 W Town And Country, Ste 200
ORANGE, CA 92868-4723
760-729-2929
725 W Town And Country Rd, 200
ORANGE, CA 92868-4723
714-347-1300
725 W Town And Country Rd, 200
ORANGE, CA 92868-4709
BUILDING PERMIT FEE ($2000+)
BUILDING PlAN CHECK FEE (BLDG)
COMMUNITY FACILITIES DISTRICT (CFD) FEE -RES
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PlAN CHECK & INSPECTION
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLOG RESIDENTIAL NEW/ADDITION/REMODEL
PUBLIC FACILITIES FEES· inside CFO
SB1473 GREEN BUILDING STATE STANDARDS FEE
SDCWA SYSTEM CAPACITY CHARGE 3/4" Displacement
SEWER BENEFIT AREA FEES - B
SEWER CONNECTION FEE (General Capacity all areas)
STRONG MOTION-RESIDENTIAL
SWPPP INSPECTION FEE TIER 1 -Medium BLDG
TRAFFIC IMPACT Residential Single Family w/i n CFO
TRAFFIC IMPACT Residential Single Family w/in CFO
WATER METER FEE 1" Displacement
WATER SERVICE CONNECTION FEE 3/4" DISPlACEMENT (P)
WATER TREATMENT CAPACITY CHARGE 3/4" Displacement
Total Fees: $42,430.99 Total Payments To Date:
760· 720•5485
$39,550.99 Balance Due: $2,880.00
1635 Faraday Avenue, Carlsbad, CA 92008· 7314 I 760-602-2700 I 760-602·8560 f I www.carlsbadca.gov
$2,907.00
$1,872.11
$2,858.17
$96.00
$166.00
$110.00
$224.00
$14,377.02
$32.00
$5,099.00
$1,304.00
$934.00
$102.69
$232.00
$2,800.00
$2,880.00
$352.00
$5,944.00
$141.00
Permit Typo: BLDG-Associated Permit Residential Application Date: 01/12/2017 Owner: RANCHO COSTERA LLC -
2483-1 NACTIVE
Work Class: Single Family Detached Issue Date: 01/03/2018 Subdivision:
Status: Closed -Finaled Expiration Date: 02/05/2019 Address: 2530 Glasgow Dr
Carlsbad, CA 92010-5602
IVR Number: 1435
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re inspection Complete
~ ...... ~-.----
06/07/2018 06/07/2018 BLOG-84 Rough 060274-2018 Cancelled Chris Renfro Reins pection Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-14 No
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout No
BLDG-34 Rough Electrical No
BLDG-44 No
Rough-Ducts-Dampers
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
06/11/2018 06/11/2018 BLDG-17 Interior 060625-2018 Cancelled Chris Renfro Reinspection Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
06/13/2018 06/11/2018 BLDG-18 Exterior 060626-2018 Passed Chris Renfro Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
08/09/2018 08/09/2018 BLDG-Electric Meter 066684-2018 Passed Chrl$ Renfro Complete
Release
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
09/12/2018 09/12/2018 BLOG.Final 069846·2018 Passed Chris Renfro Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
September 12, 2018 Page 2 of3
~ '<-,:,-i~p; ,,t
. PERMIT INSPECTION HISTORY·REPORT°(CBRA2017-0009L,' ',
"' " "" J 7. " l "~. / , / "," '' " ' ; ' '' ~ '.;, '"'l t "
Permit Type: BLDG-Associated Permit Residential Application Date: 01/12/2017 Owner: RANCHO COSTERA LLC -
2483-INACTIVE
Work Class: Single Family Detached Issue Date: 01/03/2018 Subdivision:
Status: Closed -Finaled Expiration Date: 02/05/2019 Address: 2530 Glasgow Dr
IVR Number: 1435
Carlsbad, CA 92010-5602
~---,..-,··--
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete ., .... _________
03/07/2018 0310712018 BLDG-21 050974-2018 Passed Chris Renfro Complete
Underground/Underf
loor Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
0310812018 03/08/2018 BLDG-21 051156-2018 Passed Chris Renfro Complete
Underground/Underf
loor Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-22 051154-2018 PasHd Chris Renfro Complete
Sewer/Water Service
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
04/02/2018 04/02/2018 BLDG-11 063479-2018 Passed Chris Renfro Complete
Foundation/Ftg/Pler
11 (Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
05117/2018 05/17/2018 BLDG-15 058190-2018 Passed Ch rls Renfro Complete
Roof/ReRoof (Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
05/25/2018 06/26/2018 BLDG-13 Shear 059220-2018 Passed Chris Renfro Complete
Panels/HO (ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
06/0612018 06/06/2018 BLOG-84 Rough 060033-2018 Passed Chris Renfro Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
September 12, 2018 Page 1 of 3
~ITY OF
CARLSBAD
RECORD COPY
_ CBRA2017-0009
2530 GLASGOW·DR
Building Division INSPECTION RECORD THE BLUFFS: PHASE 7 II LOT 42 II PLAN 41/ 4.995 SF-
lf648 SF Gt.RAGE// 248 SF CA ROOM
.fi'-.INSPECTION RECORD CARD WITH APPROVED
f 1 · 'LAN$ MUST BE KEPT ON THE JOB
': 1:lf CALL BEFORE 3:00 pm FOR NEXT WORK DAY INSPECTION
@ FOR BUILDING INSPECTION CALL: 760-602-272 5
OR GO TO: www.Carfsbadca.gov/Bufldfng AND CLICK ON
DEV2016-0071 2081910800
PC201 .. 7-0003-~ 9/13/2017
"Request Inspection" CBRA2017-0009
DATE:
Required Prior to Requesting Building Final If Checlced YES
Planning/Landscape
CM&I (Engineering Inspections)
Fire Prevention
#12 REINFORCED STEEL
#66 MASONRY PRE GROUT
("'' -\ 0 GROUT D WALL DRA1NS
·-'''iFlO TILT PANELS
#11 POUR STRIPS
#11 COLUMN FOOTINGS
#14 SUBFRAME D FLOOR D CEILING
#15 ROOF SHEATHING
#13 l:XT. SHEAR PAWBS
#16 INSULATION
#18 EXJERIOR LATH
#17 INTERIORLATH&DRYWALL
#51 POOL EXCA/STEEL/BOND/FENCE
#55 PREPLASTER/FINAL
#27 TUB & SHOWER PAN
#23 0 GASTEST D GAS PIPING
#25 WATERHEATER
#28 SOlAR WATER
#29 ANAL
Coo,.:it STORMWATER
#600 PRE-CONSTRUCTION MEETING
{"" 13 FOLLOW UP INSPECTION
',",o05 NOTICE TO CLEAN
#607 WRITTEN WARNING
#609 NOTICEOFVIOIATION
#610 VERBAL WARNING
REV10J2016
760.944-8463
760-438-3891
76Q-602-4660
Allow 48 hours
Call before 2 pm
Allow 48 hours
#82 · DRYWALL,EXT LATH, GAS TES {17 ,18,23}
#83 ROOF SHEATING, EXr SHEAR (13,15)
#84 FRAME ROUGH COMBO {14,24,34,44)
T-Bar (14,14,34,44)
ANAL OCCUPANCY {19,29,39,49)
A/5 UNDERGROUND HYDRO
A/SUNDERGRODNDFLUSH
A/S OVERHEAD VISUAL
A/S OVERHEAD HYDROSTATIC
A/SFINAL
F/AROUGH-IN
F/AFINAL
FIXED EXTINGUISHING SYSTEM ROUGH-IN
FIXED EXTING SYSTEM HYDROSTATIC TEST
FIXED EXTINGUISHING S ),'I FINAL
MEDICAL GAS PRESSURE TEST
MEDICAL GAS RNAL
Date Inspector
SEE BACK FOR SPECIAL NOTES
-· . Southw$St lnspectio~ and Testing, Inc.
441 comrnercra1 Way, La Habra, ca 90631
(562) 941·2990 • (714) 526-8441 • Fax (582) 948-0026
~~"'!."""'~----..~~--,~--~--SW F[. Job No.
REGISTERED INSPECTOR'S DAILY REPORT t(,c)tZ,o · ~
TYPE OF
INSPECTION
REQUIRED
Reinforced Concrete ~ Post Tensioned Concrete 'D-R$inforoed Masonry
Material Descriplion (type, grade. source)
Welding D Fireproofing D Asphatt.
Tract No.
Architect
Engineer
TESTS PERFORMED
AIR CONC WATER TIME
SET# TRUCK# TICICET #
SAMPLE
LOCATION SLUMP TEMP TEMP ADDED CAST MIX#
D · D Wood Framing
D Other
LotNo.
REMARKS
,.
INSPECTION SUIIMARY-LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN", WORK REJEcTED, JOB PROBLEMS, PROGRESS,
REMARKS, ETC. INCLUDES INFORMATION ABOUT -AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER. TYPE & !DENT. NO'S
TEST SAMPLES TAKEN;: smucr. CONNECllONS MADE H. T. BOllo TORQUED ctECKED ETC.
.,,
CONTINUED ON NEXf PAGE D PAGE OF
TIMEIN TIIIEOUT SAMPLES
SPEaALTY AGENCY
White-Oflics Copy• Canary-Accounting Copy• Pink-lnspeclDr's Copy • Goldenrod-Jobsite Copy
mf-1149 rs t¥=-< .s <-~~
)SWthwast In&pedlOl1 8. Tesllng. Inc. ~
Project Name:
i
Unit/Phase/Lots:
Initials: LF
Date: 3/21 / I~
Initials: L£
Date: 3/2 7 /J B
lnitials:__.L ..... F __ _
Date: 3/z1//B
Notes:
0
Project No.:
Author:
CA L-rz_:
Contractor:
fronh
O·.
Report No.:
Day:Mrcle one) -F/(K',(S M (J) W T F S S
Foreman:
Weather: (circle one)
vercast Rainy Other: ____ _
Plan File No.
Footin Observation Summa :
A representative of LGC Valley, Inc. observed the on-site soil conditions. The soil conditions at
the site are substantially in conformance with those assumed in the geotechnical report.
A representative of LGC Valley, Inc. observed the footing excavation(s). The footing
excavation(s} extend into the proper bearing strata and are in general conformance with the
recommendations of the geotechnical report.
1. Footing excavations should be cleaned of loose soil and debris and thoroughly moistened just prior to placing the concrete.
2. Line and grade of the footing excavation(s) are not part of the purview of LGC Valley, Inc.
3. In the event of a site change subsequent to our observation of footing excavations and prior to concrete placement (i.e. heavy rain, a
construction/placement delay, etc.), LGC should be contacted to perform a recheck of footing excavations and site observations,
as necessary.
FOOTING OBSERVATION
SUMMARY
White-File Copy Yellow -Client Copy
... ..-.....
2.0
Technician Hours
LGC VALLEY, INC.
Geotechnical Consulting
Gold -ClienUAgency Copy
.. -
Michael Baker
INTERNATIONAL
March 20, 2018
City of Carlsbad
Building Department
1635 Faraday Avenue
Carlsbad, CA 92008
Subject:
Inspector:
Bluffs -Lots 40, 41, 42, 43, & 59
City of Carlsbad Tract No. CT 13-03
JN 143824
Michael Baker International has performed a field survey on March 20, 2018 to field check the
building footing forms for Lots 40-43 & 59 on Glasgow Drive. The results of the field survey reveal
the footing forms to be within substantial conformance, both horizontally (0.1 O'~ and vertically
(0.05':t) with the City of Carlsbad approved precise grade plans DWG 480-3C, dated January 5,
2017.
Sincerely,
Tim Thiele, P.E.
Project Manager
H:\PDATA\143824_ROBERTS0N RANCI-MDMIN\CORRESPNDNC\FORM CERTS\TOLL BRO_FORM_PA5_CERT08_ 40-43,59.DOC
PLANNING • DESIGN • CCNSTRUCTICN
5050 Avenida Encinas, Suite 260, Cartsbad, California 92008 # 760.476.9193 # FAX 760.476.9198