Loading...
HomeMy WebLinkAbout2532 LUCIERNAGA ST; ; CB091066; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 08-06-2009 Residential Permit Permit No: CB091066 Building Inspection Request Line (760) 602-2725 Job Address: 2532 LUCIERNAGA ST CBAD Permit Type: RESDNTL Sub Type: RAD 0 5A Status: Parcel No: 2152502300 Lot#: Applied: Valuation: $21,500.00 Construction Type: Entered By: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 0 0 GILLEY RESIDENCE Reference #: Plan Approved: Structure Type: Issued: Bathrooms: 0 Inspect Area: Orig PC#: 168 SF PATIO, 260 SF ATTIC CONVERSION, STAIR REMODEL, DOORS Plan Check# &WINDOWS Applicant: GILLEY 2532 LUCIERNAGA ST CARLSBAD CA 92009 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee HMP Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee $227.01 $0.00 $147.56 $0.00 $0.00 $2.15 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $1.00 Owner: GILLEY 2532 LUCIERNAGA ST CARLSBAD CA 92009 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWA Fee CFO Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing lnlieu Fee Housing Credit Fee Master Drainage Fee Sewer Fee Additional Fees TOTAL PERMIT FEES ISSUED 06/26/2009 MOP 08/06/2009 08/06/2009 Total Fees $421.72 Total Payments To Date: $421. 72 Balance Due: Inspector: Clearance: $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $20.00 $24.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $421.72 $0.00 NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees,exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required infonnation with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any f I ins fwhi h h v r vi I n iv naN Tl E imilar thi ora to which th s t limi in h x ire, City of Carlsbad 1635 Faraday Ave .. Carlsbad, CA 92008 760-60~•2717 / 2718/ 2719 Fax: 760-602-8558 www.carlsbadca.gov ISuilding Permit Application JOB ADr,1:mss Z.S'3'2. "' s+. CT/PROJF"i;n LOT# PHASE# DESCRl'PTIUN OF WORK: Include Square Feet of Affected Area(s) # OF UNITS # BEDROOMS Plan Check No. Est. Value Date SUITE#/SPACE#/UNIT# APN -Z.IS zso 23 -oc # BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE CCC. GROUP ~. -w-~ EXISTING us~:;,=-=--==---=-----Ji?.h;;;;;..,,;;::::..~::::==~G"A"'R;A"G;E:;(S;;F;;)~;P;A~Tl~O~S~(S;;F~)~=,;,,,.-!!~~~;.;;>,,,,,...---~A~IR=co"N~D"l~T"IO~N~IN~G~r.F~IR"E"S"P"R~IN~K~L""'E"R"s- YES □ NOD YES □ NOD CONTACT NAME (If Different Fom Applicant) APPLICANT NAME ADDRES~, ADDRESS s+. CITY STATE ZIP· CITY ZIP PHONE FAX PHONE 7r,o. u<.. • oi<o3 EMAIL EMAIL ~ille G o..,ebox P~0:--1:::R.,\' OWNER NAME ; tie CONTRACTOR BUS. NAME ADDRESS CITY STATE ZIP CITY STATE ZIP PHONE PHONE FAX EMAtl EMAIL ARCH/DE~:fr,'IJER NAME & ADDRESS Sa-w .-: "'+-STATE UC.# STATE UC.# CLASS CITY BUS. UC.# (Sec. 7011.5 F11;, 1m and rolmion1 Code: Any City or Countr which requires a permit to con1truct, aim/ improve,. demolith or rtP.air any 11ructurt, prior to its i11umt, also requires the ap,Plicant for such P,ennit to file a i:igned statement that he is t1cen1ed JIUriun ~ the proris1on1 of tht Contmtor's Lictnie Law {Chapm 9, commending with Section . 000 of Division 3 of the Busine11 and Pr01e11i0n1 Code} or 1ha1 he is erempt thtrt fi-om. and the b:nis for the alleged exemption. Any riolation of Section 1031.5 ~' any applicant for a permit subjem the applicant to a civil penalty of not more 1han live hundred dollan {$500}). ERS' COMPENSATION ' Workers' C.lmpensatlon Declaration: / hereby affirm under penalty of perjury one of the following declarations: D I ha·.i(, 1nd wm maintain a certificate of consent to self-Insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance ol the work for which this permit is issued. D I hav~ ,i,nd wlll maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which thiS permit is issued. My workers' compensation insurance carrier and policy numi'le1 are: Insurance Co. Policy No. ______________ Expiration Date _________ _ This sectio'l 11eed not be completed if the permit is for one hundred dollars ($100) or less. D Certh"i,:.,te of Exemption: I certify that in the performance of the worl< for which this permit is issued, t shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civll fines up to one hundred thousand dollars (&100,000), ln addition to the cost of compensation, damages as provided for In Section 3706 of the Labor code, Interest and attorney's fees. £5 CONTRACTOR SIGNATURE DATE I h y affirm tl1at I am exempt from Contractor's License Law for the following reason: as owne: of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon. and who does such worl< himself or through his own employees, provided that such improvements are not intended or offered for :,ale. II, h1lWeuer, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose ol sale). □ I, as owner ol the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of p·operty who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). □ I arn exempt under Section _______ Business and Professions Code for this reason: t. : i)ersona!ly plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No ~. I (have/ have not) signed an application for a building permit for the proposed work. :i. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address/ phone/ contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons lo provide the work indicated (include name/ address/ phone/ type of work): Is the app1ic.an'. or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 Or 25534 of the Presley-T<nnrr Hazardous Substance Account Act? □ Yes □ No Is the app11can1 or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No IF ANY OF'THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCV SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I certify tha. 1 ,1,1ve read the application and state that the above lnfonnatlon Is correct and that the infonnatlon on the plans is accurate. I agree to comply with all City oldlnances and State laws relating to bullding construction. I hereby al ltK1rize representative of the City of Cartsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ,U .. LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An ·J:°il"IA permit is required for excavations over 5'0' deep and demolition or constnciion of structures over 3 stories in height. EXPIRATICr-.: Every permit issued by the Building Official under the provisions of this Code shaK expire by !imitation and become nuH and void tt the building or work authorized by such permit is not commenced within 180 days fm11 the date of such permit or tt the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Unttorm Building Code). RS APPLICANT'S SlGNATURE DATE City of Carlsbad Bldg Inspection Request For: 01/26/2010 Permit# CB091066 Inspector Assignment: RB Title: GILLEY RESIDENCE Description: 168 SF PATIO, 260 SF ATTIC CONVERSION, STAIR REMODEL, DOORS & WINDOWS Sub Type: RAD --- Type: RESDNTL Phone: 7602160863 Job Address: 2532 LUCIERNAGA ST Lot: Suite: Location: APPLICANT GILLEY Owner: GILLEY CASEN&JAMIE Remarks: Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical 0 Comments/Notices/Holds Inspector: Requested By: NA Entered By: BINSPECT Associated PCRs/CVs Original PC# CV070207 CLOSED Z-ROOMS FOR RENT SIGN IN YARD: lnsi:1ection Histo[J'. Date Description Act 1nsp Comments 10/29/2009 27 Shower Pan/Roman Tubs AP PY 10/27/2009 23 Gas/Test/Repairs AP RB STILL MISSING SHOWER PAN TEST 09/30/2009 17 Interior Lath/Drywall AP RB 09/30/2009 18 Exterior Lath/Drywall AP RB 09/30/2009 27 Shower Pan/Roman Tubs NR RB 09/25/2009 16 Insulation AP RB 09/25/2009 27 Shower Pan/Roman Tubs NR RB 09/18/2009 14 Frame/Steel/Bolting/Welding AP PY 09/18/2009 24 Rough/T opout AP PY NEED HOT MOP 09/18/2009 34 Rough Electric AP PY 09/18/2009 44 Rough/Ducts/Dampers AP PY NEED #12@ BATH 08/26/2009 21 Underground/Under Floor AP RB 08/26/2009 24 Rough/Topout co RB LEAK City of Carlsbad BUILDING DEPARTMENT 1635 Faraday Avenue, Carlsbad, CA 92008 Phone: 760-602-7541/ Fax: 760-602-8558 Plan Checb Comments / :2007 Codes ,64-)( L/39-1f 3S- From: Steve Borossay To: G_ I LLfL'i <°R_e_ :'!>. Fax: 86G.--B6E, ·· 7Jf 18 Pages: Phone: 7 'Z.D ..-1 C. '3 Date: Re: QC::> 0~ \IC) c;G Address: z..s-g,z. G.lcter- -+frO·iii=M'i;?Jj,j;Jil@j:{lf;t+ff@i'jfj,fQhhUUI3=1i;Ji•J,\j!;,141W1 ❖ Please make corrections referred to below and run TWO new prints. If red marks are on plans as a part of this Plan Check response please return red marked set with the new prints. ❖ This is a BUILDING REVIEW ONLY. Comments or approval do not apply to any other City department review. For information on the status of approval from other departments please contact staff@760-602-2717 / 2718 / 2719. a:Jc_JC\_~0"'-5 {..: C. ~ ,:_ J bJ R<2_ C ~ f, r ~ e , b.e-s .f-o.._ ""'-r ~ d.. D. DESIGN REQUIREMENTS 1. Specify an window llizea and operation types (e.g., slider, casement, single-hung, etc.). Items 0.2, 0.3, D. 10, and Section G will be evaluated at next re-check. 2. Provide window area of at least 8% of the floor area In each room or show on utility plan permanently wired lighting supplying average illumination of 10 foot-candles over area of the room at 30" height. (CBC 1206.2 and 1206.3) 3. Provide openable door/window area to the outdoors of at least 4% of the floor area in each room or provide dNlfilned mechanical ventilation system supplying continuous outdoor air and exhaust per the California Mechanical Code and show on utility plan. (CBC 1203.4.1 and CMC Chapter 4) 4. Provide adequate opening In common wait between ___ and ____ to meet natural lighting requirernSlla olllllm 0.2. The opening muat be at leasl 50% of the common -11 area and at least 10% of the floor area of the Interior room or 25 sq. II., whicll9-is greater. (CBC 1205.2.1) 5. Provide adequate opening In common wall between ___ and ____ to meet natural ventilation requlrenN9idll of ltarn 0.3. The opening must be at least 8% of Iha floor area of Iha interior room or 25 sq. It, whichever ia greater. (CBC 1203.4.1. 1) 6. Habitable rooms (eia:ept kitchens) shall not be less lhan 7'·0" In any dimension or 70 sq. It in area. Kitchens ahall be at least 50 sq. It In area with 3' -0" clearance between counters and appliances/walls. (CBC 1208. 1 and 1208.3) 7. Show 7'-8" minimum calling height for habitable rooms (e,a:ept kitchens) and hallways. (CBC 1208.2) 8. Show 7'-0" minimum calling height for kitchens, storage rooms, laundry rooms, and bathrooms. (CBC 1208.2) 9. Show permanently wired amolce detectors for new conatructlon at the following locations (CBC 907.2.10. 1.2): a) In each sleeping room; b) on the celUng or wal outalde each separate sleeping area; c) at each story within the dwelling unit. 10. Sleeping rooms and baHmenta must have an exterior eg,-door or window (CBC t 028.2, t 028.3 and t 028.5) with: e) 5.7 sq. It minimum net clear openable area (5.0 sq. II. for grade-level openings); b) 24" minimum net clear openable height; c) 20" minimum net clNr openable width; d) bottom of Iha clear opening not greater lhan 44• above Iha floor; e) direct opening to pubic way or yaldlcourt opening to public way; f) window wela of 9 sq. fl horfzontaJ area and 38" minimum dimensions and equipped with laddera/stepa for escape. 11. Room labeled ____ is considered a habitable space/sleeping room. Items 0.2, 0.3, 0.6., 0.7, 0.9, and 0.10 may apply. 12. Hallways shall be a minimum width of 36". (CBC 1017.2) 13. Show stairways and landlnga (CBC 1009. 1, 1009.2, 1009.3, 1009.4, 1012.2, 1205.4) with: a) minimum width ol 38"; b) minimum headroom of 8' -8"; c) rile belv,een •• and 7.1s•: A . minimum run 0110• (for winding stairs: 6" minimum at narroweat point and to• minimum at 12• from inside radlue); tread noalnga between o. 75" and 1.25" on stairways with solid risers (when treads leae lhan 11 "); qp minimum landing deplh of 38"; handrail height 34" to 38" above llead nosings; permanently wired lighting of not leae lhan 1 foot-candle at tread runs; i) complete structural delaiffng. 14. Enclosed space under stairs to be protected wilh 1/2" gypsum board on the enclosed side. (CBC 1009.5.3) ./(!) Provide 42" -high protective guardrail for porches, balconies, decks, and open sides of landings. Maximum clear opening between any members of Iha guardrail shall be leae lhan 4". (CBC 1013.2 and 1013.3) 16. Exterior doors may not swing outward for drops eia:eading 112• (CBC 1008.1.6). Dimension all drops at exterior doors. 17. Safety glazing (tempered glaaa) i8 required (CBC 2406.3) for windows: a) adjacent to balhlUba, sho-rs, hot IUba, whlrfpools, and saunas, and within 60" of the floor; b) within a 24" arc of either vertical edge of doors in the closed poeitlon and wilhln 60" of the floor; c) within 18" vertically and 38" horizontally of a walliing surface, where the Individual pane is greater than 9 sq. It. and the to. edge is greater than 38" above the floor; d) adjacent to stailwaya, rampe, and landings, or within 5' -'1' horizontally of the bottom of stairways, where the bottom edge i8 within 60" of lhe walking surface. 18. Detail floor/ceiling and waN assembll• be'-8" dwelling units. Show 1-hour fire-resistance rating (112-hour rating allowed in dwellings equipped with fire sprinklers) and sound transmlulon control. (CBC 419.2, 419.3, and 1207.8) E. GARAGE REQUIREMENTS 1. Provide minimum 112" gypsum board 1rom floor to roof shealhing on garage side of walla separating garage and dwelling unit. (CBC -408. 1.4) 2. Provide minimum 5/8" Type X gypeum board at garage ceHlnga with habHable rooms above and minimum 112" gypsum board at walls supporting thil floor/ceiling fire separation. (CBC 406.1.4 and 711.-4) 3. Door between garage and dwelling shall be self-closing, tight-fitting, and either 1 318" •thick solid WOOd or 20-mlnule ftre-piotecllon rated. (CBC 408.1.4) 4. Doore may not awing into garage when there Is more than 112• drop 1rom the house (CBC 1008.1.8). Dimension the step from the house to Ille garage. 5. Under no clrcumstanc• are garages allowed to open Into a room used for sleeping purposee. (CBC 408.1.4) 8. Provide a minimum 18" high platform -1rom source of Ignition -for water heater and heating/cooing equipment capable of Igniting flammable vapors (unlNa llstlng report number provided showing lgnitlon-realstant appffance). (CPC 508.1-4(1) and CMC 308.1) 7. Provide protection of water heater and/or heatlng/coollng equipment subject to vehicular impact. (CPC 508.14) F. ELECTRICAL, MECHANICAL, AND PLUMBING REQUIREMENTS 1. Provide an electrical legend to Identify aN symbols used. 2. Ground Fault Circuit Interrupter (GFCI) outleta are required In bathrooma, at kitchen countertopa, laundry and wat bar sinks, in garagee, in crawlspaces, In unfinished basementa, and outdoora. (CEC 210.8) 3. Bedroom electrical clrcuila muat ba protected by Arc Faull ClrcuH Interrupter (AFCI) outlela. (CEC 210.12) 4. Storage rooms/areas are allowed only one light and ona electrfcal outlet. &. i\1attl an ,,,.,,._ CAie ,Nlj11t •Mil ., ... ,ty ... lhl C j I •• 5 lliNIAI eNiAMII,• 8. On Ille floor plan, show Ille location of all electrlcal panels (meter panels and sub panala). Provide a 3'1' wide by 38" deep worlcapace in front cl all panele. Panels .,. to be located to minimize the probability of communicating fire lo adfacent combuettble materials. Panels are not allowed·ln bathrooms. 7. Indicate location cl heating units and water heatel'II on floor plan. (CBC 1204.1) 8. Gas-Hred water healel'II and fumacN located in bedrooms or balhrooma muat uss outdoor combustion air and be installed in a 7 cloaet with a listed gaaketed, self-clolJng door (e,cept clrect-vant appffances). Closet muat be for elCCIUaive use of water heater / r,i"\ and/or fumace. (CPC 505.0 and CMC 904.1) @ Provide 30" x 30" 11Jk; accw In hallway or other acceaalble location for mechanical equipment In the attic. A 22" x 3(1' acceaa may.be used If the ls!ll88t place of -,ulpment .~ be l'1IITIOVed through the opening. (CMC 904.11) at.:.o ne.ed ~~,It./-• 9W'i. -!ch (? FRu 1 o. Note on plans lhat water heitera require a minimum of two (2) strape to resist horizontal dleplacement. Specify a minimum of~• x 24,gauge strape with 14• x 3• lag bolts attached directly to the framing. (CPC 508.2) 11. Show a minimum 4' diameter dryer vent to extarior. Vent limited to 14'-0" lenglh with two 90" bends. (CMC 504.3.2.1) 12. Show mak•up air source for clothes dryer located in closet. Provide 100 sq. in. minimum opening. (CMC 504.3.2) 13. Provide exhaust fans in bathrooms, powder rooms and water closet compartments. (CMC Table 4-4) 14. Provide 30" widlh and 24" front clearance at water closete. (CPC 407.6) ,OOF. ASSE~BLY REQUIREMENTS 1. . Specify roof material and undertayment. 2. Specify ICC, UL, or equivalent listing report number and manufacturer tor roofing material (tile, metal, buift-up, etc.). 3. Note on the plans: "Roofing shall have a cl888 'A' fire rating." • 4. Specify roof pitch. 5. Roof pitch is not adequate tor roof type specified (CBC Chapter 15). Provide minimum pitch of __ _ 6. Specify 1/4":12" minimum roof pitch for drainage or design to support accumula1ed water. (CBC 1506.1) 7. Detail roof drains/overflows and show their locationa. Separate drain and overflow outleta required. (CPC 1101.11) 6. Specify approved waterproof decking material for bak:onles/decka over interior spacea (CBC 1402.3). Specify ICC, UL, or equivalent listing report number. 9. Provide calculation showing attic ventilation area of at leaat 1/15o"' of attic area. Indicate wnt sizeS and locations on roof plan. Venta muat be located to provide adequate crou 119ntilatlon. (CBC 1203.2) /G Specify ICC, UL, or equivalent listing report number for skyllghta. Show skylight size& and locattons on floor plan and roof plan. J. FRAMING REQUIREMENTS 1 . Provide a complele rool/lloor framing plan. 2. Show on plans all recommendations made In engineering cak:ulations. 3. Provide complete structural detailing tor the project. 4. Croes-reference all framing details with the appropriate plans • . 5. 1>a1e& al nQl)-appfk:able detaile from plans. v© Special Inspection 1s required 1or: ; e.-lr"o.h'. l-A~ -.s. 83~• (r=; a t · ss.• .,r :re J 1 pat d pl Sr Mr srttesrt ns; ,t ;.;iiilizzsi.rCTs 21,a; <Fin►, ✓ @ Provide a large,clwnote'ar,ihep~p;.,.: "Special inspection is required. ~t■■■■ ■■■ 1,111111n,,.11111■11l11W1 •~•••I 8. Specify plywood grade, thlckn-, panel span rating, and nailing for roolllloor aheathlng. (CBC Table 2304. 7(3)) 9. Note on p/ana: "Plywood shall be contlnuoue under California fill.• rt 10. Specify size, orientslfon, and spacing of al members -ratters, ceiling jolatll, beams, floor jolets, headers, pasta, columns -on framing plans. 11 • Provide two complete seta of ll'U88 drawing■ (CBC 2303.4). Coordinate with roof framing plan. 12. Identify 11'118888 on roof framing plan by fll&'IO/aequence number or males trusa layout a pennanent part of plans. 13. Design ll'U8888 for bearing at perpendicular interior shear walle. 14. Specify 112" clearance~ lnJS8e8 and OQl)-bearing walla. 15. Show support for ridgalhlp/valley intersectlona. 16. Provide rafter ties where ceiling jolatll are perpendicular to rafters. (CBC 2308.10.4. 1) 17. Provide metal straps acrosa ridge beam and rafters. 18. Specify camber requirementa and combination symbol for all glu.lamlna1ed wood membera on plans. 19. Note on plans: 'A certificate of conformance is required prior to framing inspection for glue-laminated wood membera. • 20. Specify the make and model number of all proposed trusa/beamfJQist hangers. 21. Specify size and type (double stud, post, etc.) of support for beams/headers -4x12 and larger -and girder trusses. 22. Detail all beam-to-post, post-t~beam. and cost-t~fooflno r.nnn..,,.;nn• • • -,...---·, -~-:-.......... Q,11'-' .,._,cl\,111\jl IUI CIH wa, ... 14. Balk><in frame walls of rooms with sloping ceilings (rake walls). Specify on plans which walls are balloon framed. K. LATERAL REQUIREMENTS 1 . Show location, type, and length of all shear wall■ on structural pl-and coordinate with shaar-wall schedule . .,, .@ Specify nail size and spacing for an shear walla and roof/floor diaphragms. Specify required blocking. /v. Provide llhaar-tranal9t" connacllon dalaila for shear walls (Interior and extertor) at roof, floors, and foundation. Crou-rafenlnce al ✓ \..::J shear-transfer clelaill with Iha appropriate plan■. 4. Make manufacluNr'1 stn,ctu,al datail ahaal(a) for englna■red lhaar panell (e.g., Strong-Wal, Hardy Frame, TJ, Si.. Max. ate.) a pannanant part of Iha plane. / © Buildng doee not meat conwnllonal braClng raquiramenlll alCBC 2308. Provicfa angi11Nred dNlgn for lateral-lOlca rasietanc:8 • ..,...,...,@ Spacing balwaan interior and exterior braced wall Jina■ lhall not excaad 25'0" on uch ■to,y (CBC 2308.12.3). -(!) Shear walla lhall start at not more lhan 8'-0" from each end al a braced wal line. (CBC 2308.12.4) 8. Cumulaliva langlh al shear walla on each raqulred braced wal Jina shall comply with CBC 2308.9.3 and 2308.12.4. 9. Maintain mulmum shNr well dlmanaion retlm per CBC Table 2305.3.4. 10. AN ■hear panall mu■t extend to Iha roofllloor diaphragm lllloft. 11. Provide drag strap■ on each side al bey wlndo-N and llulih bNrn■ ~ plate llr1a■ .,. interrupted: 12. Whara ehaar wall fon:a■ eia:aacl 350 pounds par foal, all foundation sill plates and fnlmlng mambenl r■calvlng edge nalllng shall ba minimum 3x rnamber (CBC 2306.3.11 and Table 2308.4.1). /. @Specify locstlon,1ypa al all ~ on foundation plan (grade-level hold-downs) and framing plan (upper-level hold-down■). ✓@ Justify Iha short-penocl n,aponsa acceleration, Sa, and 1·sacond period responaa accalsratlon, s,, used In Iha engineering calculatlona. (CBC 1813) , 15. Justify Iha ra■ponss modification coafllciant, R, usad in Iha anglnaarlng calculaltona (CBC 1813). ' 18. Justify Iha value allha l"IICUld■ncy fsclor, p, used In Iha augll1a■rlng cslculsliona (CBC 1813). L FOUNDATION Rl!QUIREIIENTII ✓ (D Provld9 e complala and fully dfmanaklnad foundation plan. 2. Show on plan■ al rscommandatlolw from llolla and/or compacllan raporta. 3. Provld9 calculallon shOwlng und■c1loor "9l1lllatlon opanlngl al at 111118t 1/150"' al crawl•~ .,.._ lnclcala vent slzae and localkn on foundallon plan. Vanll must ba locatad IIO • lo provide adequate CRIN vanlllallon. (CBC 1203.3) 4. Show minimum 111" x 24" ICCNI to all crawl-space area■ on foundation plan. (CBC 1209.1) · 5. Provide undllrlloor claaranca of 18" for floor joja1a and 12" for floor glrdenl off grade. (CBC 2304.11.2. 1 J 8. Show Ir clssrance off~ grade for wood !nun~ raatlng on axtartorfaundallon wsllllfoollng■. (CBC 2304. 11.2.2) 7. Foundation plalal or llilla shd ba bolled to Iha foundation with not lw lhan 112"-dlamaler stNI bolta ambacldad at laMI r into concrate or ,-,y Ind spaced l'ICJI more than 8'-o" apart. The.-. ■hall be a minimum cf two bolls parplsce wilh ona bolt locatad not more lhan 12" or,_ than 4" from each and of each place. Staal plala washers • minimum cf 3" x 3• x o.229" shall ba used on each boll (CBC 2308.8 and 2308.12.8) ✓@ Noffl on fo4Jndalion plan: • AN hokl-downa must ba tied in place prior to foundation inapaclton. • 9. Provide footing dataile spaclfylng al dimensions and relntorcamant. Crosa-ralaranca aH detaill with foundation plan. 10. Provide adaquat■ looting■ under all bearing walls and shear walls. 11. Pt"Ollida spread looting■ under:--------------~ 12. Specify slab lhlcknass, reinforcement and moisture berriar. PLANNING/ENGINEERING APPROVALS PERMIT NUMBER c(__B D~~ DATE_____._z_/_z,,,_A_o_'J __ ADDRESS_--->=:>:........:::.S----=-3_,,Z..=--=L=u....~~..:....{~.:....:...=-,-._.,l,-._~...,__ __ g~ __ RESIDENTIAL RESIDENTIAL ADDITION MINOR . (<$17,000.00) TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER __________________ _ DATE _______ _ DATE___;;,7...._/4..;;;._e-.-'-/i...:..::OJ;:__ __ Oocs/Miaforma/Planning Engineering Approvals ( ~ 1, ~ !ii !ii "Ii 1 ~ u u C C /l. /l. 1:81 □ □ 1:81 □ □ 1:81 □ □ 1:81 □ □ 1:81 □ □ PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB09-1066 Address 2532 Luciernaga Planner Chris Sexton Phone ....,(7-"6,,,0,_\ ""60"'2._-...;;4,:,6,.,2c,c4 _______ _ APN: 215-250-23 Type of Project & Use: addition Net Project Density: 1.8 DU/AC Zoning: R-2 General Plan: RM Facilities Management Zone: __ CFO (in/out) #_Date of participation: __ Remaining net dev acres: __ Circle One (For non-residential development: Type of land used created by this permit: __ ) Legend: 1:81 Item Complete D Item Incomplete -Needs your action Environmental Review Required: YES D NO 181 TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES □ NO 181 TYPE __ APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: __ Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES D NO 1:81. CA Coastal Commission Authority? YES O NO 0 If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Habitat Management Plan Data Entry Completed? YES □ NO 0 If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, tool bar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) lncluslonary Housing Fee required: YES D NO D (Effective date of lnclusionary Housing Ordinance -May 21, 1993.) Data Entry Completed? YES □ NO □ (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) H:\ADMIN\Template\Building Plancheck Review Checklist.doc Rev 4/08 Site Plan: [8J □ □ [8J □ □ □□□ [8J □□ [8J □ □ [8J □ □ [8J □□ [8J □ □ □□□ . ---~---,-·-··---- Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. Policy 44 -Neighborhood Architectural Design Guidelines 1. Applicability: YES □ NO □ 2. Project complies: YES D NOD Zoning: 1. Setbacks: Front: Interior Side: Street Side: Rear: Top of slope: Required 20' Shown 20' Required 7'2" Shown 7'6" Required __ Shown __ Required 15'4" Shown 20' Required __ Shown __ 2. Accessory structure setbacks: Front: Required __ Shown __ Interior Side: Required __ Shown __ Street Side: Required __ Shown __ Rear: Required __ Shown __ Structure separation: Required __ Shown __ 3. Lot Coverage: Required >50% Shown 20% 4. Height: Required >30' Shown >30' 5. Parking: Spaces Required g Shown g (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required __ Shown __ Additional Comments ~ OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTE~DATE"l=..L~i H:\ADMIN\Template\Building Plancheck Review Checklist.doc Rev 4/08