Loading...
HomeMy WebLinkAbout2534 West Ranch St; ; CB161994; Permit(city of Carlsbad Print Date: 12/31/2018 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2534 West Ranch St BLDG-Residential 2081951000 $2,129,655.00 ROBERTSON RANCH WEST VILlAGE Residential Permit Work Class: Apartments Lot#: Reference#: DEV11017 Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: Description: RESDNTL-APT MONTECITO: 13 UNIT APT BLDG TYPE 1 / 14,924 SF APT AREA/ 2,447 SF GARAGE (BLDG #12) Applicant: ALLIANCE LAND PLANNING AND ENGINEERING INC ELIZABETH SHOEMAKER 2248 Faraday Ave Carlsbad, CA 92008-7208 760-431-9896 Total Fees: Owner: SHAPELL MONTECITO LLC 8383 Wilshire Blvd, 700 Beverly Hills, CA 90211-2400 323-988-7590 Total Payments To Date: Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Permit No: CB161994 Closed -Finaled 05/19/2016 10/11/2016 12/31/2018 11:53:29AM 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov I ·-·- Permit Print Date: 01/04/2019 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: Description: FEE Total Fees: Building Division 2534 West Ranch St BLDG-Migrated 2081951000 $ 0.00 Work Class: BLDG-Migrated Lot#: Reference#: DEV11017 Construction Type Bathrooms: Orig. Plan Check#: Plan Check#: ROBERTSON RANCH WEST VILLAGE SWPPP -MONTECITO APARTMENTS BUILDING #12 Total Payments To Date : (City of Carlsbad Permit No: SW160475 Status: Applied: Issued: Permit Fina led: Inspector: Final Inspection: Closed -Finaled 09/27/2016 10/11/2016 01/04/2019 AMOUNT Balance Due: 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov , , PERMtT INSPECTION HISTORY REPORT (CBi61994) Permit Type: BLDG-Residential Application Dato: 05/19/2016 Owner: Work Class: Apartments Issue Date: 10/11/2016 Subdivision: Status: Closed -Finaled Expiration Dato: 06/24/2019 Address: IVR Number: 714663 Scheduled Date Actual Start Date Inspection Type Inspection No. Inspection Status Primary Inspector 12126/2018 12/26/2018 12/31/2018 12131/2018 December 31, 2018 BLDG-Final Inspection BLDG-Final Inspection Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final 080061-2018 Checklist Item BLOG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Structural Final BLDG-Electrical Final BLDG-Electrical Final Partial Pass Michael Collins COMMENTS Partial 12/26/18, check accessible space striping TCO. See back inspection card. Inspected all garages, exit signs, AC units. All OK Passed COMMENTS 12/31/18 Partial Michael Collins 12/26/18, check accessible space striping TCO. See back inspection card. Inspected all garages, exit signs, AC units. All OK SHAPELL MONTECITO LLC 2534 West Ranch St Carlsbad, CA Reinspection Complete Reinspection Incomplete Passed Yes No Yes Yes Yes Yes Yes Complete Passed Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Page9of9 ' • ' y •• . ·. PERMIT INSPECTION HISTORY REPORT (0B161994) Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: Work Class: Apartments Issue Date: 10/11/2016 Subdivision: Statl1s: Closed -Finaled Expiration Date: 06/24/2019 Address: IVR Number: 714663 Scheduled Actual Inspection Type Inspection No. Date Start Date Inspection Status Primary Inspector 04/30/2018 0413012018 BLDG-23 056635-2018 Gas/Test/Repairs Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency 08/22/2018 0812112018 BLDG-Final 067552-2018 Inspection Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final 08/2912018 08/29/2018 BLDG-Flnal 068590-2018 Inspection Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final 1211112018 12/11/2018 BLDG-Final 078415-2018 Inspection Checklist ltern BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLOG-Structural Final BLDG-Electrical Final 12/24/2018 12/24/2018 BLDG-Final 079793-2018 Inspection Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLOG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final December 31, 2018 Passed Michael Collins COMMENTS Unit 301 ok All units except Unit 301 ok. Partlal Pass Chris Renfro COMMENTS TCO. See back inspection card Partial Pass Chris Renfro COMMENTS TCO. See back inspection card. Inspected all garages, exit signs. AC units. All OK Partial Pass Mlchael Collins COMMENTS Partial TCO. See back inspection card. Inspected all garages, exit signs, AC units. All OK Cancelled Paul Burnette COMMENTS Partial TCO. See back inspection card. Inspected all garages, exit signs, AC units. All OK SHAPELL MONTECITO LLC 2534 West Ranch St Carlsbad, CA Reinspection Passed Yes Yes Reinspection Passed No No No No No Retnspection Passed Yes Yes Yes Yes Yes Reinspection Passed Yes Yes Yes Yes Yes Yes Relnspection Passed Yes Yes Yes Yes Yes Yes Complete Complete Incomplete Incomplete Incomplete Complete Page 8 of 9 ' " , PERMIT INSPECTION HISTORY REPORT (CB161994) ' ' Permit fypo: BLDG-Residential Application Date: 05/19/2016 Owner: Work Class. Apartments Issue Date: 10/11/2016 Subdivision: Status: Closed -Finaled Expiration Date: 06/24/2019 Address: IVR Number: 714663 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector BLDG-18 Exterior 050773-2018 Passed Michael Collins Lath/Drywall Checklist Item COMMENTS BLDG-Building Deficiency Interior stairwells & 3rd floor only BLDG-Building Deficiency BLOG-Building Deficiency Not ready BLDG-Building Deficiency Prelim at exterior before wrap 03/09/2018 03109/2018 BLDG-17 Interior 051252-2018 Cancelled Chris Renfro Lath/Drywall Checklist Item COMMENTS BLDG•Building Deficiency BLDG-82 Drywall, 051253-2018 Cancelled Chris Renfro Exterior Lath, Gas Test, Hot Mop Checklist Item COMMENTS BLDG-Building Deficiency BLDG-17 Interior lath-Drywall BLDG-18 Exterior Lath and Drywall BLOG-23 Gas-Test-Repairs 03/12/2018 03/12/2018 BLDG-17 Interior 051379-2018 Partial Pass Michael Colllns Lath/Drywall Checklist Item COMMENTS BLDG-Building Deficiency Partial at Units 202-205, 302, 304-305. See card for notes at Unit 202. 03/13/2018 03/13/2018 BLDG-82 Drywall, 051587-2018 Failed Michael Colllns Exterior Lath, Gas Test, Hot Mop Checklist Item COMMENTS BLDG-Building Deficiency Not ready BLDG-17 Interior Lath-Drywall 03/14/2018 03/14/2018 BLDG-17 Interior 051734-2018 Passed Michael Collins Lath/Drywall Checklist Item COMMENTS BLDG-Building Deficiency Completion of units & garages. BLDG-Building Deficiency 04/27/2018 04/27/2018 BLDG-23 056317-2018 Partial Pass Michael Collins Gas/Test/Repairs Checklist Item COMMENTS BLDG-Building Deficiency All units except Unit 301 ok. ,--·-··-~- December 31, 2018 SHAPELL MONTECITO LLC 2534 West Ranch St Carlsbad, CA Re inspection Passed Yes Yes No Yes Reinspection Passed Yes Reinspection Passed No No No No Reinspection Passed Yes Reinspectlon Passed No No Passed Yes Yes Reinspection Passed Yes Complete Complete Complete Complete Incomplete Complete Complete Incomplete Page 7 of 9 , PERMIT INSPECTION HISTORY REPORT (CB161994) Permit Type: BLDG-Residential Apartments Closed -Finaled Application Date: 05/19/2016 10/11/2016 06/24/2019 714663 Owner: Work Class: Status: Scheduled Date 03/01/2018 Actual Start Date 03/01/2018 03/05/2018 03105/2018 0310612018 03/0612018 December 31, 2018 Issue Date: Subdivision: Expiration Date: Address: IVR Number: Inspection Type BLDG-84 Rough Combo(14,24,34,44) Inspection No. 050282-2018 Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding {Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers BLDG-14 Frame/Steel/Bolting/ Welding (Decks) 050751-2018 Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-16 Insulation 050823-2018 Checklist Item BLDG-Building Deficiency BLDG-18 Exterior Lath/Drywall 050579-2018 Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-84 Rough Combo(14,24,34,44) 050580-2018 Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers BLOG-16 Insulation 050774-2018 Checklist Item BLDG-Building Deficiency Inspection Status Primary Inspector Partial Pass Mlchael Collins COMMENTS Units 101,201,301-305, no garages Partlal Pass Michael Collins COMMENTS 2nd & 3rd floor RC installation. As noted on card Partial Pass Michael Collins COMMENTS Units 201-205,301-305 Partial Pass Michael Collins COMMENTS Not ready Interior stairwells & 3rd floor only Prelim at exterior before wrap Passed Michael Collins COMMENTS Completion of garage framing. Units 102-103, 202,204-205 only See card for minor pickup Passed Michael Collins COMMENTS Need cert for blown insulation at 3rd floor ceiling SHAPELL MONTECITO LLC 2534 West Ranch St Carlsbad, CA Reinspection Reinspection Passed Yes Yes Yes Yes Yes Reinspectlon Passed Yes Yes Reinspection Passed Yes Reinspection Passed No Yes Yes Passed Yes Yes Yes Yes Yes Yes Passed Yes Complete Incomplete Incomplete Incomplete Incomplete Complete Complete Page6of9 ! ' ' ', PERMIT INSPECTION HISTORY REPORT (CB161994) Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: Work Class: Apartments Issue Dato: 10/11/2016 Subdivision: Status: Closed -Finaled Expiration Date: 06/24/2019 Address: IVR Number: 714663 Scheduled Date Actual Start Date Inspection Type Inspection No. 01/12/2018 01/12/2018 01/24/2018 01/24/2018 01/25/2018 01/25/2018 01/26/2018 01/26/2018 02/28/2018 02/28/2018 December 31, 2018 Checklist ltcm BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-17 Interior Lath/Drywall 045764-2018 CheckHst Item BLDG-Building Deficiency BLDG-17 Interior Lath/Drywall 046749-2018 Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-18 Exterior Lath/Drywall 046895-2018 Chee kHst Item BLDG-Building Deficiency BLDG-14 Frame/Steel/Bolting/ Welding (Decks) 046987-2018 Checklist Item BLDG-Building Deficiency BLDG-18 Exterior Lath/Drywall 050147-2018 Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-84 Rough Combo(14,24,34,44) 050148-2018 Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding {Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers Inspection Status Primary Inspector COMMENTS Cancelled per contractor Cancelled per contractor Cancelled per contractor Wrong code Wrong code Partial Pass Andy Krogh COMMENTS Wrong code exterior shear Failed Michael Collins COMMENTS Not ready Wrong code exterior shear Partial Pass Michael Collins COMMENTS Prelim at exterior before wrap Partial Pass Andy Krogh COMMENTS As noted on card Failed Michael Collins COMMENTS Not ready Prelim at exterior before wrap Partial Pass Michael Collins COMMENTS Units 102-103, 202,204-205 only. See card for minor pickup SHAPELL MONTECITO LLC 2534 West Ranch St Carlsbad, CA Reinspection Passed Yes Yes Yes Yes Yes Reinspection Passed Yes Re inspection Passed No Yes Relnspection Passed Yes Re inspection Passed Yes Relnspection Passed No Yes Reinspectlon Passed Yes Yes Yes Yes Yes Complete Incomplete Complete Incomplete Incomplete Complete Incomplete Page 5 of 9 ' · • PERMIT INSPECTION HISTORY REPORT (CB161994) Pcrrnit Type BLDG-Residential Application Date: 05/19/2016 Owner: SHAPELL MONTECITO LLC Work Class: Apartments Issue Date: 10/11/2016 Subdivision: Status: Closed -Finaled Expiration Date: 06/24/2019 Address: 2534 West Ranch St Carlsbad, CA IVR Number: 714663 Scheduled Actual Reinspection Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Complete 12/06/2017 12/06/2017 BLDG•24 042484•2017 Partial Pass Mlchael Collins Reinspection Incomplete Rough/To pout Checklist Item COMMENTS Passed BLDG-Building Deficiency Waste/vent except, Unit 203 auto washer. Yes BLDG-Building Deficiency Not ready No 12/12/2017 12/12/2017 BLDG-24 043155-2017 Passed Michael Collins Complete Rough/Topout Checklist Item COMMENTS Passed BLDG-Building Deficiency Unit 203 Ok Yes BLDG-Building Deficiency Waste/vent except, Unit 203 auto washer. Yes BLDG-Building Deficiency Not ready No 12/19/2017 12/19/2017 BLDG-15 043736-2017 Cancelled Michael Collins Reinspection Complete Roof/ReRoof {Patio) Checklist Item COMMENTS Passed BLOG-Building Deficiency Cancelled per contractor No BLDG-Building Deficiency Wrong code No BLDG-Building Deficiency Cancelled per contractor No BLDG-Building Deficiency Wrong code No BLDG-24 043735-2017 Passed Michael Collins Complete Rough/To pout Checklist Item COMMENTS Passed BLDG-Building Deficiency Tub trap prelim, all units Yes BLDG-Building Deficiency Not ready No 12121/2017 12/21/2017 BLDG-14 044120-2017 Failed Michael Collins Reinspection Complete Frame/Steel/Bolting/ Weldlng (Decks) Checklist Item COMMENTS Passed BLOG-Building Deficiency Not ready No BLDG-Building Deficiency Cancelled per contractor No BLDG-15 044119-2017 Cancelled Michael Collins Reinspection Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Cancelled per contractor No BLDG-Building Deficiency Cancelled per contractor No BLDG-Building Deficiency Wrong code No BLDG-Building Deficiency Cancelled per contractor No BLDG-Building Deficiency Wrong code No 12/29/2017 12/29/2017 BLDG-15 044649-2017 Partial Pass Chris Renfro Reinspection Incomplete Roof/ReRoof (Patio) December 31, 2018 Page 4 of9 ' ' - , , PERMIT INSPECTION HISTORY REPORT (CB161994) Permit Type: Work Class: Status: Scheduled Date 10/13/2017 10(1712017 11/29/2017 12/01/2017 12/04/2017 1210512017 BLDG-Residential Application Date: 05/19/2016 Owner: Apartments Issue Dato: 10/11/2016 Subdivision: Closed -Finaled Expiration Date: 06/24/2019 Address: Actual Start Date 10113/2017 10/17/2017 11/29/2017 12101/2017 12/04/2017 12/0512017 IVR Number: 714663 Inspection Type Inspection No. BLDG-14 037526-2017 Frame/Steel/Bolting/ Welding (Decks) Checklist Item BLDG-Building Deficiency BLDG-15 037525-2017 RooflReRoof (Patio) Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-16 Insulation 037985-2017 Checklist Item BLDG-Building Deficiency BLDG-15 041741-2017 Roof/ReRoof (Patio) Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-24 041740-2017 Rough/Topout Checklist Item BLDG-Building Deficiency BLDG-24 041874-2017 Rough/Topout Checklist Item BLDG-Building Deficiency Checklist Item BLDG-Building Deficiency BLDG-24 042173-2017 Rough/Topout Checklist Item BLDG-Building Deficiency BLDG-24 042420-2017 Rough/Topout Checklist Item BLDG-Building Deficiency Inspection Status Primary Inspector Cancelled Michael Colllns COMMENTS Cancelled per contractor Cancelled Michael Colllns COMMENTS Cancelled per contractor Wrong code Passed Michael Collins COMMENTS HVAC platfor prelim insulation Cancelled Michael Collins COMMENTS Cancelled per contractor Cancelled per contractor Wrong code Failed Michael Collins COMMENTS Not ready Withdrawn Andy Krogh COMMENTS COMMENTS Not ready Passed Michael Collins COMMENTS Prelim tub drains except Unit 303 Failed Michael Collins COMMENTS Not ready December 31, 2018 SHAPELL MONTECITO LLC 2534 West Ranch St Carlsbad, CA Relnspection Complete Reinspection Complete Passed No Refnspectlon Complete Passed No No Complete Passed Yes Reinspection Complete Passed No No No Reinspection Complete Passed No Reinspectlon Complete Passed No Passed No Complete Passed Yes Reinspection Complete Passed No Page 3 of9 ' " ' "' . PERMIT INSPECTION HISTORY REPORT (OB161994) . . Pnrrnit Type: BLDG-Residential Application Date; 05/19/2016 Owner: Work Class: Apartments lssuo Date: 10/11/2016 Subdivision: Status: Closed -Finaled Expiration Date: 06/24/2019 Address: Scheduled Actual Date Start Date 07/06/2017 07/06/2017 08/18/2017 08/18/2017 09/18/2017 09/18/2017 09/19/2017 09/19/2017 09/21/2017 09/21/2017 09/22/2017 09/22/2017 09/25/2017 09/25/2017 December 31, 2018 IVR Number: 714663 Inspection Type Inspection No. BLDG-17 Interior 027850-2017 Lath/Drywall Checklist Item BLDG-Building Deficiency BLDG-13 Shear 028019-2017 Panels/HD (ok to wrap) Checklist Item BLDG-Building Deficiency BLDG-15 032175-2017 Roof/ReRoof (Patio) Checklist Item BLDG-Building Deficiency BLDG-15 034952-2017 Roof/ReRoof (Patio) Checklist Item BLDG-Building Deficiency BLDG-15 Roof/ReRoof (Patio) 035038-2017 Checklist Item BLDG-Building Deficiency BLDG-15 Roof/ReRoof (Patio) 035279-2017 Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-15 RooffReRoof (Patio) 035723-2017 Checklist Item BLOG-Building Deficiency BLDG-Building Deficiency BLDG-15 Roof/ReRoof (Patio) 035676-2017 Chocklist Item BLDG-Building Deficiency Inspection Status Primary Inspector Failed Andy Krogh COMMENTS Wrong code Passed Jonathan West COMMENTS Floor sheeting 3rd floor Partial Pass Mlchael Collins COMMENTS Roof sheathing nailing only. Need truss walk Partial Pass Michael Collins COMMENTS Roof sheathing nailing only. Need truss walk Failed Michael Colllns COMMENTS Failed Michael Collins COMMENTS Not ready Roof sheathing nailing only. Need truss walk Passed Mlchael Collins COMMENTS Roof sheathing nailing only. Need truss walk Not ready Cancelled Michael Collins COMMENTS Wrong code SHAPELL MONTECITO LLC 2534 West Ranch St Carlsbad. CA Reinspection Reinspection Passed No Passed Yes Reinspection Passed Yes Reinspectlon Passed Yes Relnspection Passed No Relnspection Passed No Yes Passed Yes No Re inspection Passed No Complete Complete Complete Incomplete Incomplete Complete Complete Complete Complete Page 2 of9 PERMIT INSPECTION HISTORY REPORT (CB161994) Permit Type: BLDG-Residential Application Dato: 05/19/2016 Owner: Work Class: Apartments Issue Date: 10/11/2016 Subdivision: Status: Closed -Finaled Expiration Date: 06/24/2019 Address: Scheduled Actual Date Start Date 09122/2017 03/20/2017 0312012017 03/21/2017 0312112017 03/24/2017 03/24/2017 03/2812017 0312812017 05/25/2017 05/25/2017 07105(2017 07/05/2017 December 31, 2018 IVR Number: 714663 Inspection Type Inspection No. BLDG-17 Interior 028018-2017 Lath/Drywall Checklist Item BLDG-Building Deficiency BLDG-Electric Meter 060054-2018 Release Checklist Item BLDG-Building Deficiency BLDG-21 016990-2017 Underground/Underf loor Plumbing Checklist Item BLDG-Building Deficiency BLOG-21 017161-2017 Underground/Underf loor Plumbing Checklist Item BLOG-Building Deficiency BLDG-Building Deficiency BLDG-22 017626-2017 Sewer/Water Service Checklist Item BLDG-Building Deficiency BLDG-11 017931-2017 FoundatlonfFtg/Pier s (Rebar) Checklist Item BLDG-Building Deficiency BLDG-14 024620-2017 Frame/Steel/Bolting/ Welding (Decks) Checklist Item BLDG-Building Deficiency BLDG-13 Shear Panels/HD (ok to wrap) 027851-2017 Checklist Item BLDG-Building Deficiency Inspection Status Primary Inspector Cancelled Andy Krogh COMMENTS Wrong code Passed Andy Krogh COMMENTS all 13 units and hm Partial Pass Michael Collins COMMENTS Waste to exterior of building Line only. Double click Unit B3.1 for 4" waste. Passed Michael Colllns COMMENTS 4" waste section ok. Waste to exterior of building Line only. Double click Unit 83.1 for 4" waste. Passed Jonathan West COMMENTS Passed Michael Collins COMMENTS Received PT & soils report. Passed Mlchael Collins COMMENTS 2nd floor, floor sheathing drag nailing and CS straps. Falled Andy Krogh COMMENTS Floor sheeting missing straps SHAPELL MONTECITO LLC 2534 West Ranch St Carlsbad, CA Reinspection Complete Reinspection Complete Passed No Complete Passed Yes Reinspection Incomplete Passed No Complete Passed No No Complete Passed Yes Complete Passed Yes Complete Passed Yes Re inspection Complete Passed No Page1of9 ~ RECORD COPY '~ ~ CH-, OJ CB161994 2534 WEST RANCH ST MONTECITO· 13 UNIT APT CARLSBAD Building Division INSPECTION RECORD BLDG TYPE 1 / 14 924 SF APT AREA/ 2 447 SF GARAGE (BLDG #12) ' RESDNTL APT li1l INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB lot# 1 ALLIANCE LAND PLANNING & @ CALL BEFORE 3 :30 pm FOR NEXT WORK DAY INSPECTION @ FOR BUILDING INSPECTION CALL: 760-602-2725 OR GO TO: www.Carfsbadca,goy/Bujfding AND CLICK ON #Request Inspection" DATE: lO -l \ -l l.1) ENGINEERING INC If "YES" is checked below that Division·s approval is re11uired prior to requesting a Final Building Inspection. If you have any questions please call the applicable divi,;ions at the phone numbers provided below. After a ll required approvals are signed off-fa>. to 760-602-8560. email to 1Jldginspcctions<0'C_<!rl_sb,,Jlc_i10 go_v or hring in a COPY of this card to: 1635 Faraday Ave .. Carlsbad. mm --■ •mm■ Required Prior to Requesting Building Final If Checked YES Ill .. 1111 Planning/Landscape CM&I (Engineering Inspections) •m■ Fire Prevention --■ --COD£" BUILDING REINFORCED STEEL #66 MASONRY PRE GROUT □GROUT D WALL DRAINS #10 TILT PANELS #11 POUR STRIPS #11 COLUMN FOOTINGS #14 SUBFRAME O FLOOR O CEILING #15 ROOF SHEATHING #13 #16 INSULATION #18 EXTERIOR LATH #17 INTERIOR LATH & DRYWALL #51 POOL EXCA/STEEL/BOND /FENCE #55 PREPLASTER/ANAL #27 #23 #25 #603 FOLLOW UP INSPECTION #605 NOTICETO CLEAN . #607 WRITTEN WARNING #609 NOTICE OF VIOLATION #610 VERBAL WARNING REV 1012012 760-944-8463 7 60-438-3891 760-602-4660 Allow 48 hours Call befo.re 2 pm 1111 , 'JJ,f. Allow 48 hours #31 #34 #33 llllfiJ/11/II ~ 1111 II■ #35 PHOTO VOLTAIC COOE" MECHANICAL #41 UNDERGROUND DUCTS & PIPING #44 0 DUCT & rWIUM O REF. rlrtNG #43 HEAT-AIR COND. SYSTEMS COOK" COMBO INSPECTION #81 UNDERGROUND (U.,12,21,31) #82 DRYWALL,EXT LATH, GAS TES (17,18,23) #83 ROOfSHEATING, EXT SHEAR (13,15) #84 FRAMEROUGH COMBO (14,24,34,44) #BS T-Bar(14,24,34,44) FINAL OCCUPANCY (19,29,39,49) A/S UNDERGROUND VISUAL A/5 UNDERGROUND HYDRO A/S UNDERGROUND FLUSH A/S OVERHEAD VISUAL A/S OVERHEAD HYDROSTATIC A/SANAL F/A ROUGH-IN F/AANAL AXEO EXTINGUISHING SYSTEM ROUGH-IN AXED EXTING SYSTEM HYDROSTATIC TEST FIXED"EXTINGUISHING SYSTEM ANAL MEDICAL GAS PRESSURE TEST MEDICAL GAS ANAL Date Ins ector SEE BACK FOR SPECIAL NOTES Project Name: fZ o 'oe,y.\sa vi S "'-". Location: f.o~ Client: MK.eq Soil Engineer: Geologist: fl-a 12 +oo,\\ Date: Report No.: Project No.: ;~~-o, 3,/2;7 / zo17 Author: Weather: (circle one) Sunny Overcast Plan File No. Observation Summary: Rainy Day: (circle one) M T w T F Foreman: (Yl,(.'2- Other: Permit No. (13fitl 'l4"f s s Initials: ~'- Date ?A.z-1 (2ot7 A representative of LGC Valley, Inc. observed the on-site soil conditions. The soil conditions at the site are substantially in conformance with those assumed in the geotechnical report. Initials:~ Date: 3/2,7[un7 Initials: ~l... Date: Z, b,7J UIJ Initials: f>R- Date: ~linl2011 Notes: A representative of LGC Valley, Inc. observed the footing excavation(s). The footing excavation(s) extend into the proper bearing strata and are in general conformance with the recommendations of the geotechnical report. A representative of LGC Valley, Inc. measured the footing setback from the slope face. The setback was in general a=rdance with the recommendations of the geotechnical report. ~s=~~- 1. Footing excavations should be cleaned of loose debris and thoroughly moistened just prior to placing the concrete. 2. Based on the expansion potential of the underlying soils, presoaking of soil below slabs may be recommended. Consult the geotechnical report for the presoaking recommendations. We note that clayey soils may take an extended period of time and the contractor should schedule accordingly. 3. In the event of a site change subsequent to our footing observation and prior to concrete placement (i.e. heavy rain, a construction/placement delay, etc.), we should be contacted to perform additional site observations, as necessary. 4. Line and grade of the footing excavation(s) are not part of the purview of LGC Valley, Inc. 5. Soil compaction test results, including depth of fill, relative compaction, bearing values, and soil expansion index test results are contained in the As-Graded Geotechnical Report provided at the completion of grading. !6fljk~, For LGCVa~ , Date FOOTING OBSERVATION SUMMARY Received by: Print: White -File Copy Yellow -Client Copy Pink -Field Copy LGC VALLEY, INC. Geotechnical Consulting Gold -Client/Agency Copy ,. • NOVA Srrvire?-> Daily Report Robertson's Ranch, Montecito Robertson\'s Ranch West Village Carlsbad , Ca Job#: 1016519 WEATHER Time 07:06AM 12:00PM TIME ARRIVAL Temp 54°F 64°F 07:00 AM Monica Hernandez Arrived onsite at 0700. REFERENCED DOCUMENTS 07:02 AM Monica Hernandez Hum W·Dir 99% SSW 95% SSW Referenced approved structural drawings and pt drawings. PERMIT NUMBERS 07:01 AM Monica Hernandez Permit#CB161994. 2534 W Ranch St. Carlsbad, Ca. REINFORCING STEEL 11:13 AM Monica Hernandez W·Speed 3MPH 9MPH W-Gust 5MPH 12MPH Tuesday, Mar 28, 2017 Precip Condition 0 IN Clear QIN Clear Verified the reinforcing steel installation for bldg 12 foundation, including trim bars, backing bars and added steel. Verified the installation of hold downs and anchor bolts per framing plan. Verified steel for size, grade, lap, spacing and clearances. All steel in final place. Powered By NoteVault Nova Services, Inc. I Robertson's Ranch, Montecito I Tuesday, Mar 28, 2017 I Page 1 of 3 PRESTRESSED CONCRETE 11:10 AM Monica Hernandez Verified the installation of pt tendons for bldg 12 foundation. Verified tendons for size, profile, quantities and hardware. All tendons in final place. COMPLIANCE 0 1:09 PM Monica Hernandez All work is compliant with approved documents. TIME DEPARTED Powered By Not eVault Nova Services. Inc. I Robertson's Ranch, Montecito I Tuesday, Mar 28, 2017 I Page 2 of 3 01:09 PM Monica Hernandez Departed at 1300 PM. Powered By NoteVault Nova Services, Inc. I Robertson's Ranch, Montecito I Tuesday, Mar 28, 20171 Page 3 of 3