Loading...
HomeMy WebLinkAbout2535 STATE ST; ; CB151281; Permitf • _ City of Carlsbad ''•. 1635 Faraday Av Carlsbad, CA 92008 10-19-2015 Residential Permit Permit No: CB151281 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: 2535 STATE ST CBAD RESDNTL 2030543436 $325,364.00 1 0 Sub Type: CONDO Lot#: 36 Constuctlon Type: 58 Reference tt_-C=r-t30005] Structure Type: MF5"+ · Bathrooms: 0 Orig PC #~'~-"G"-c-~4-0-037J Status: ISSUED Applied: 04/28/2015 Entered By: JMA Plan Approved: 10/15/2015 · Issued: 10/15/2015 · Inspect Area: Plan Check#: PC150022 Project Title: STATE ST. TOWNHOMES: PHS 3 83 435 SF 1 ST FLR COMMERCIAU1 ,892 SF LIV/ 444 SF GAR/ 73 SF BALCONY/ 683 SF ROOF DECK Applicant: TAYLOR MORRISON OF CA, LLC STE 1450 100 SPECTRUM DR IRVINE CA 92618-4935 949-341-1289 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check ,Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee HMP Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee Green Bldg Stands Plan Chk Fee $1,423.84 $0.00 $996.69 ($500.00) $0.00 $42.30 $6,190.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $3,931.00 FS1 $0.00 $0.00 $14.00 $0.00 Total Fees: $29,808.95 Total Payments to Date: Owner: Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWA Fee CFO Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (~304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing lnlieu Fee Housing Credit Fee Master Drainage Fee Sewer Fee Additional Fees Fire Sprinkler Fees TOTAL PERMIT FEES $29,808.95 Balance Due: FS1 $0.00 $317.00 $4,800.00 $0.00 $5,921.62 $5,466.12 $0.00 $0.00 $0.00 $0.00 $0.00 $210.00 $89.00 $65.38 $0.00 $0.00 $0.00 $0.00 $842.00 $0.00 $0.00 $29,808.95 $0.00 Inspector: Clearance: ------ f\OTl CE: F'tea9e take flOTl CE cl yar ptject trdl.des the irflX)31ticn" ri fees, 00'.lcatlms, reservalcns, rr ctlH -1fml hffis!a" CXl1ooM:fy raared lo as iee&'6'1mkr,s." Yoo rave 00 days frcrn the d3te !tis poorit vei lssu:!d to p-ctest I~ ri traie fees/~ If }OJ ~ !tan, yru rrust fdloNthe ~ Jnnrli'8s set fath In C?oMrrrent Cooe Sedlm 60020(a), cn:l file the pda!t cn:l m; cth:r n'q.lrfrl lrtooretla1 v.lth the Qty Mngar fa" ~l'YJ In ocanm:e vJth Ca1sba:J Mrddpal Cooe Sooia1 3.32.cm FalLUe to tirrely fcilON!ta ~ wU l:a" 'f!nf Sl.b:aµrt legal a:l!m to~ reM6'A\ set aside, \de!, er a-ru ttar lnµisltlm Yoo 8'0 hatbJ RRTI-ffi N:JTJRB) that yar r1gl1 to f7dest the ~oo fees/B<a'.llcns OCES flOT PPR... Ytowm cn:l f!J31,f;X' cx:medla, fees cn:l CBp<dty cra,ges, ncr J)aTlrg, zmrg, 11acf rg er ctrer slrriia"" ~lcalm ~l'YJ er S€f\1al fees In amedbl wth tHs ptject. t--m oces rr ~ Y to ITTf Inspection List Pennlt#: CB151281 Type: RESDNTL CONDO _!;>ate _ _ _ Inspection Item ____ _ 06/22/2016 89 Final Combo 05/17/2016 39 Final Electrical 04/04/2016 17 Interior Lath/Drywall 04/04/2016 23 Gas/Test/Repairs 03/30/2016 18 Exterior Lath/Drywall 03/28/2016 84 Rough Combo 03/21/2016 84 Rough Combo 03/08/2016 13 Shear Panels/HD's 03/07/2016 13 Shear Panels/HD's 03/07/2016 13 Shear Panels/HD's 02/24/2016 15 Roof/Reroof 02/16/2016 17 Interior Lath/Drywall 02/08/2016 f5 Roof/Reroof 01/21/2016 17 Interior Lath/Drywall 12/01/2015 81 Underground c·ombo 11/13/2015 21 Underground/Under Floor Friday, July 15, 2016 Inspector ___ Act PY AP PY PA PY AP PY ·AP PY AP PY AP PY PY PY PY PY PY PY PY PY PB CA AP CA CA AP PA AP PA AP AP STATE ST. TO.WNHOMES: PHS 3 83 435 SF 1ST FLR COMMERCIAU1,892 SF L Comments · Page 1 of 1 <~'> '\!i"' CI TY a r CARLSBAD r-· •lldlng Division INSPECTJON RECORD ._..INSPECTION RECORD CARD WJTH APPROVED PLANS MUST BE KEPT ON TI-IE JOB CB151281 2535 STATE ST STATE ST. TOWNHOMES: PHS 3 B3 435 SF 1 ST FLR COMMERCIAU1 ,892 SF UV/ 444 SF GAR/ 73 SF BALCONY/ 6B3 SF ROOF DECK RESDNTI.. CONDO Let#: 36 TAYLOR MORRISON OF CA. LLC 0 CAU BEFORE 3;30 pm FOR NEXT WORK DAY INSPECTION 0 FOR BUILDING INSPECTION CALL: 760-602-2725 RECORD COPY OR GO TO: www.Carlsb21dca,goy/Bulldlng AND CLICK ON ~Reqpest Inspection- DATE: -\~-I Required Prior to Requesting Bulldlng Flnaf ff Checked YES Plarv11ng/landscape 760-944-8463 Allow 48 hours CM&I (£nglnccrtng lnspcctlom) 760438-3891 Call before 2 pm Fire Prevention 760-602-4660 l\llow 48 hours #11 #12 REINFORCED STEEt #34 ROUGH ELECTRIC ''66 MASONRY PRE GROUT #33 0 aECTRtC SERVlCE O TEMPORARY '-" 0 GR9UT D WALL DRAINS #35 PHOTO VOLTAIC #10 TILT PANELS #39 FINAL ~~~~~~~~~~~~-1-~~~~~~~~--1 #11 POUR STRIPS #11 COWMN FOOTINGS #41 UNDERGROUND DUCTS & PIPING #14 SUBFRAME D FLOOR D CEILING 0 DUCT & PLEIIUM D REF. PIPING #16 ROOF SHEATHING HEAT-AIR COND. SYSTU'IS #13 EXT. SHEAR PANflS . 1116 INSULATION #18 EXTERIOR LATII #17 INTERIOR LATH & DRYWALL DRYWAU.,EXT LATH, GAS TES (17,18,23) 1151 POOL EXCA/STEU/BOND FENCE #83 ROOF SHEATING, ffi SHEAR (13,15) #56 PREPI.ASTER/ANAL *84 FRAME ROUGH COMBO (14,24,34,44) #86 T-BBr(14,24,34,44) ANAL OCCUPANCY (19,29,39,49) t.l SEWER & BL/CO D PL/CO '21 UNDERGROUND OWASTE O WTR #24 TOP OUT D WASTE D WTR #27 TUB & SHOMR PAN S UNDERGROUND HYDRO #23 GAS TEST D GAS PIPING A/5 UNDERGROUND FLUSH #25 A/S OVERHEAD VlSUAl. lt28 A/S OVERHEAD HYDROSTATIC #29 A/5 FINAL F/A ROUGlf.lN #600 F/AFUIAL #603 FtXnl EXTINGUISHING SYSTEM ROUGH•IN ,1605 NOTICE TO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST #607 WRITTEN WARNING FIXED EXTINGUISHING SYS1£M FINAL #609 NOTICE OF\IIOIATION MEDICAL GAS PRESSURE TEST #610 VERBAL WARNING MEDICAL GAS FINAL REV1CY.Z012 Date ln.rpector SE!! BACK FOR SP£C1AL NOTES ··ccityof Carlsbad CIRCUIT CARD 8-36 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov THIS CARD MUST BE PDJ.lID OlTT AND AV All.ABLE AT THE SER.VICE EQUIPMENT FOR TIIB ROUGH INSPECTION Address: J_j' JJ~ rhrrl s+'A-ttt r Permit Number. cl!, 1.r1 i .t, OWner.~,,r-.~ AJ11.6'rJu,J I Phone: &'I,) Jl/1-Jzoo Area In Sq. A. 2Jl7 Contractor: t;..__1,!Wl., k-1,c .t~e. I Phone: PANEL: 11.. 1' Jcr'o( l/41 A.LC. 11.w VOLTS 0 WIRE LOCATION CKT BKR WIRE MISC REC REC LTG MISC WIRE BKR CKT SIZE SIZE TYPE SIZE TYPE SIZE LOCATION ~~ 1 \") /¥ 7N#.U ~ ~ J 11 ~ /'I 7,Y#A/ l~ 2 ~~ 'Ol~ 3 1-.t> It II r 2· y 9 ~ I¥ II ,, 4 c ...... r.:.u~ tx,,~ 5 w /2 II ( 2 1.r l'I II ,<"' 6 <. O/k'J#c//4 (2icA', ~f 7 M 12 II l( ' ~ If II 1<,"" 8 ~TZI 1(.1 r ~~ 9. ,t,D It II 2.. (J 7-/V II ,< 10 ~/1-xA,, z... IJ,\.l t f 0 11 M 12 II I € 'I 1'1 I' I l<" 12 . ·~1/}.Jlj !Ll..,. C11tl 13 M 12. I/ z. I f /'/ II ,.<r 14 ~ Jf',f_ r<> I.I' f!A-<-4 15 1.-o 12 /I I s ' II/ ti t<" 16 7 /1 ~...,.,, ---.. ..:_'\ .NC 17 10 /2 /I I 4' t' /~ II t-=<" 18 ~ .A/G 19 7.,() IZ I/ I I /f' II ,.c-20 ~/ ...lot. 21 -z,L, /0 " I f /f" II l{"" 22 1. • •• r ~ -__ ,... . . .Jt/C-23 i,..r; /0 I/ I I /'I I/ ,< 24 /z:cfi!-1...R, lt 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 I 40 41 42 MAIN: D ~oO AMP BRK/FUSE O MLO Computed Load AMPS BUS: ~"" AMP S99 CalcustJon Worlraheet on back Branch circuits· requ Ired: Service entrence or feeder conductora: A) Ughtlng Cll'Cl.Wts 220 -3{b), 4{d) A) Size: No. B) Type: D cu D AL B) Two Small Appllance Circuits 210-11(e} C) Insulation: D) Conduit Size: __ C) Laundry Circuit 220-16(b) Service ground/bond: B) Type: 13'&u O AL D) Central Heating Equipment 422-12 A) Size: No. -:;,/o E) Bathroom 210-62(d) ~amp locatlon(s): UFER 250-50(c) Remarke: 0 Waf.£JrPlpe 250-104 D Ground Rod 250-52 D GFC~tlons 210-8, 680-70: I certify that all terminations have been torqued In accordance wfth manufacturer's Bathroom(s) D Kitchen Instructions and that the work shown on this c/rcult csrd representa the fuf1 extent of I!( Garage{!!) OHydromassage Tub the work performed under this permit. ef'Outdoors 0 D Owner AFCI Protected Clrc. 210-12 'D Contractor src.- Date 2 -~-~ cr'Bedroom(s) D Signed _,, .A__. a 8-36 Page 1 of 2 Rev. 03/09 , .. .ii. ,. SINGLE FAMILY DWELLING ELECTRICAL SERVICE LOAD CALCULATION As an alternative method, the STANDARD METHOD found In ARTICLE 220 of the National Electrlc Code, may be used 1. GENERAL LIGHTING LOADS Dwelling sq. fl x 3 VA= 220-3(a) VA Small appliance loads -220-16(a) 1500 VA x circuits= VA Laundry load -220-16(b) 150.0 VA x circuits = ' VA General Lighting Total ____ VA 2. COOKING EQUIPMENT LOADS -Nameplate Value Range VA= VA Cooktop VA= VA ~noo ~= ~ Cooking Equipment Total VA 3. ELECTRIC DRYER 220-18 (Nameplate, 5000 VA minimum) Dryer VA= Dryer Total . VA 4. FIXED APPLIANCE LOADS 230-30 (b) (3) Dishwasher = Disposal= Compactor= Water Heater = Hydromassage Bathtub = Microwave Oven = Built-In Vacuum = = 5. OPTIONAL SUBTOTAL (Add all of the above totals) 6. APPL YING DEMAND FACTORS -TABLE 220-30 First 10,000 VA x 100% = Optional Subtotal (from line 5) { Remaining ___ VA x 40%= 7. HEATING OR AC LOAD -TABLE 220-30 Larger of the Heating or AC Load .. ____ VA ____ VA ____ VA· ____ VA ____ VA ____ VA ____ VA ____ VA Fixed Appliance Total ____ VA ____ VA 10,000 VA ____ VA ____ VA 8. OPTIONAL LOADS TOT AL (Add totals from lines 6 and 7) = ____ VA 9. MINIMUM SERVICE SIZE a Optional Loads Total = 240 Volt ____ Ampere (Please put total on front of card under Computed Load) . . ' ·~ Comlnuous Inspection & Materials Testing SOUTHWEST ••••••••••••••• V~v7"'v7'vVvVVvVVVW" Inspection'& Testing, Inc. 441 Commercial Way. La Habra, CA 90631-6168 (562) 94·1-2990 • (714) 526-844 I February 18, 2016 Building Offlclal City of Carlsbad . Department of Building and Safety 1635 Faraday Ave Carlsbad, California 92008 SPECIAL INSPECTOR'S FINAL PROJECT REPORT Project Name: Seagrove Townhomes Address: Owner: State Street, PH 3 Bulldlng 5 Taylor Morrison Lot# Address Permit Lot# Address 31 2555 State Street CB151278 36 2535 State Street 32 2551 State Street CB151285 37 2531 State Street 33 2547 State Street CB151284 38 2527 State Street 34 2543 State Street CB151283 39 2523 State Street 35 2539 State Street CB151282 Permit CB151281 CB151280 CB151279 CB151277 FAX (562) 946'0026 This Is to certify that Southwest Inspection and Testing, Inc. was employed to perform special Inspection on the above mentioned project at the above address, which required contlhuous Inspection per section 1701 of 2013 caflfornia Building Cdde. Brett Albllnge.r -Reinforced Concrete, Post Tensioned Concrete, SD #656 Nell White -Reinforced Concr~te, Post Tensioned Concrete, ICC #5254958 Jeff Robertson-Reinforced Concrete, Post Tensioned Concrete, ICC # 5218723-92 · Based upon special Inspection and materials testing written reports of this work, It Is our judgment that the Inspected work was performed to the best of our knowledge, in accordance with the approved plans, specifications and applicable workmanship provision of the Callfomla Bulldlng Code. Steven L. G President SLG/IRW: amc Reviewed By: Ian R. Waddell, P.E. Principal Engineer I expressed or Implied.