HomeMy WebLinkAbout2537 STATE ST; ; CB150448; Permit'
,i·
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
04-23-2015 Residential Permit Permit No: CB150448
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
2537 STATE ST CBAD
RESDNTL
2030543405
$295,759.00
1
0
Sub Type: CONDO
Lot#: 5
Constuctlon Type: 58
Reference#: CT130005
Structure Type: MF5+
Bathrooms: 0
Status: ISSUED
Applied: 02/11/2015
Entered By: JMA
Plan Approved: 04/23/2015
Issued: 04/23/2015
Inspect Area:
Project Title:
Orig PC#: PC140037
STATE ST. TOWNHOMES: PHS 2 C1
Plan Check#: PC150021
405 SF 1 ST FLR COMMERCIAU1 ,694 SF LIV/ 4 76 SF GAR/ 67 SF
BALCONY/ 585 SF ROOF DECK
Applicant:
TAYLOR MORRISON OF CA, LLC
STE 1450
100 SPECTRUM DR
IRVINE CA 92618-4935
949-341-1289
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
HMP Fee
Pot. Water Con. Fee
Meter Size
Add'I Pol Water Con. Fee
Reel. Water Con. Fee
Green Bldg Stands (SB1473) Fee
Green Bldg Stands Plan Chk Fee
$1,317.94
$0.00
$922.56
($500.00)
$0.00
$38.45
$6,190.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$3,931.00
FS1
($3,931.00)
$0.00
$12.00
$0.00
Total Fees: $23,813.89 Total Payments to Date:
FINAL
Date:
Owner:
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWA Fee
CFO Payoff Fee
PFF (3105540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnlleu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Additional Fees
Fire Sprinkler Fees
TOTAL PERMIT FEES
$23,813.89 Balance Due:
Clearance:
FS1
$0.00
$317.00
$4,800.00
$0.00
$5,382.81
$4,968.75
$0.00
$0.00
$0.00
$0.00
$0.00
$210.00
$89.00
$65.38
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$23,813.89
$0.00
NOTICE: Please take NO CE that pproval of your project Includes the 'lmpos n' off dedications, reservations, or other exactions hereafter collectively
referred to as 'fees/exactions." You have 90 days from the elate this pem,ft was Issued to protest Imposition of these fees/exactlons. If you protest them, you must
follow the protest procedures set forth In Government Code Section 66020(a), and me the protest and any other requlred lnformatlon with the City Manager for
processing In accordance with Carlsbad Municipal Ccxle Sectlon 3.32.030. Failure to timely follow that procedure wlTI bar any subsequent legal action to attack,
revtew, set aside, void, or annul their Imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connectlon fees and capacity
changes, nor planning, zoning, gradlng or other slmllar appllca~on processing or service fees In connection with this project. NOR DOES IT APPLY to any
Inspection List
Pennlt#: CB150448 Type: RESDNTL CONDO STATE ST. TOWNHOMES: PHS 2 C1
405 SF 1ST FLR COMMERCIAU1,694 SF L
D_a_!e_ __ __ Inspection Item ____ _ Inspector __ Act. Comments
03/14/2016 89 Final Combo PY AP
03/14/2016 89 Final Combo PY AP
03/14/2016 89 Final Combo RI AM PLEASE/COF
03/09/2016 89 Final Combo RI AM PLEASE COF
03/09/2016 89 Final Combo PY co
12/03/2015 39 Final Electrlcal PY PA
10/14/2015 17 Interior Lath/Drywall PY AP
10/14/2015 23 Gas/T esURepairs PY AP
10/13/2015 17 Interior Lath/Drywall PY CA
10/07/2015 17 Interior Lath/Drywall PY AP
10/02/2015 84 Rough Combo PY AP
10/01/2015 84 Rough Combo PY NR
09/21/2015 13 Shear Panels/HO'S PY AP
09/21/2015 13 Shear Panels/HO's PY AP
09/21/2015 13 Shear Panels/HO's PY AP
09/11/2015 15 Roof/Reroof PY AP
09/01/2015 17 Interior Lath/Drywall PY PA
08/27/2015 17 Interior Lath/Drywall PY PA
08/21/2015 15 Roof/Reroof PB AP
08/05/2015 17 Interior Lath/Drywall PY PA
06/25/2015 11 Ftg/F oundation/Piers PB AP
06/04/2015 21 Underground/Under Floor PY AP
06/04/2015 22 Sewer/Water Service PY AP
Tuesday, March 15, 2016 Page 1 of 1
°'
CB150448 2537 STATE ST
INSPECTION-RECORD
STATE ST. TOWNHOMES: PHS 2 C1
405 SF 1ST FLR COMMERCIAU1 ,n94 SF UV/ 47n SF
GAR/ 67 SF BALCONY/ 585 SF ROOF DECK
RESDNTL CONDO ·....._~NSPECTION RECORD CARD WITI-1.APPROVED
Pl.ANS MUST BE KEPT ON THE JOB Let#: 5 TAYLOR MORRISON OF CA, LLC
@ CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION RECORD COPY 0 FOR BUILDING INSPECTION CALL: 760-602•2725
OR GO TO: www.C,rJsbadca,goy/BuQdlng AND CLICK ON
··Reque I on" /
Required Prior to Requesting Bulldfng ,Anal If Checked YES
Plannlng/tand.scape Allow 48 hours
CM&I (Engineering lnspectlonsJ 760-438-3891 cal before 2 pm
Are Prevention 760-602-4660 Nlow 48 hours
Type of Inspection
cor.i. ;, ELECTRICAL . . . .
131 0 ELEClilC UNDERGROUND D UFER
REINFORCED STEEL #34 ROUBH El..ECTRIC
MASONRY PRE GROUT 133 D B..ECTIUCSERVJCE D TEMPORARY
'--'' DGROUT D WAU. DRAINS '35 PHOTO VOLTAIC
#10 TILT PANELS
#11 POURST1UPS cor,:: 11 MECHANICAL.· ,. . .:
#11 COWMN FOOT1NGS #41 · UNDERGROUND DUCTS & PIPING
#14 SUBFRAME O R.OOR D CEIUNQ 144 0 DUCT & PLENUM O REF. PIPING
#15 ROOF SHEATHING #43 HEAT-AIR COND. SYSTEMS
ff13 EXT. SHEAR PANELS
#16 INSULATION ccr.r,;,: COMBO-INSPECTION . · .· ·
4'18 EXTU!IOR lATH #81 UNDER8ROUND (11,12 1)
#17 INTERIOR lATii & DRYWALL #82 DAYWAU.,EXT lATH, QAS TES {17 ,18,23)
!151 POOLEXCA/STEEI./BONP/FENCE #83 ROOF SH EATING, EXT SHEAR {13,15)
#55 PR EPLASTER/ANAL #84 FRAME ROUGH COMBO (14,14,34,44)
#85 T-Bar (14,24,34,44)
FINAL OCCUPANCY (19,29,39,49)
#22
#21
#24 TOP our D WASTE D WfR
lf27 rue & SHOWER PM
123 ml 0 GAS PIPING
#125 WATER HEATER
#28
F A ROUGR-IN
F/ARHAL
FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUQH,IN
J605 NOTICE TO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST
lt607 WRITTEN WARNING AXED EXTINGUISHING SYSTEM FINAL
/#609 NOTICE OF VIOlATION MEDICAL GAS PRESSURETEST
#610 VERBAL WARNING MEDICM GAS ANAL
Date Inspector
SEE B.A.CJ< FOR SPECW. NOTES
·;-,.
L'T(s,, .
:z_
/I
7
('city of
Carlsbad
CIRCUIT CARD
8'"36
Development Services
Bulldlng Division
1635 Faraday Avenue
. 760-602-2719
www.carlsbadca.gov
THIS CARD MUST BB FllLBD Oln' AND AV Ail..ABLB AT THE SERYICB RlltJlPMENT POR nm ROUGH INSPECTION
Address: Zs J 7 SrhW Jhtb·i-. .,.. "~"'-'-1'.0~. r..4 , 711nk-Permit Number. r..l. .1 r" "" r
Qwni,r; -,,;;,,_,~ .vi .. ~,1/f..-' T Phone: ( 'rl 'r j 'I I -ll .. 6V Area In Sq. A. ~o-,, Contractor: ~ Cit I t..L I Ai~ -p MA""'5"£ I Phone: ~/9 579 G,S'"OQ
PANEL: G"'-~ lb Io~~ A.LC. "24" VOLTS I 0 ~ WIRE
LOCATION CKT BKR WIRE MISC REC REC LTG MISC ·WIRE BKR
SIZE SIZE TYPE SIZE TYPE SIZE CKT LOCATION
I/< /Tel/Ea 1 2-Q 1-:l-av 4 'tJ /::.J. 'l/ ID CJ) ;J.5" 2 Ale
In ,e.~ 3 2.0 /2-. c.U ,. ::2£.f IOv' ID CL) ~s 4 A-Jc
l?,'4r#5 5 ;zo ' 2-cu 'S D~ ~, I:>--C{l ..2.C 6 ''"11.N( Jc,-··~-,_._'f 7 'Z 0 ,,_ c..v l-1 ;,Ll. 'O\/ I ;>-cu :za 8 SPLIT
rl-6 t, 9. /5 IV cu L I I -:i c...u ;i,o 10 e,...I A> ff€ {!.
~~ 11 IS li./ cu 3 I /;L c..v 2.{J 12 ~A-LI
l)~f'~ 13 /~ (Cl CIJ l :I I 77 I 'I CV /5 14 ~O/Sw:rl-1
IJ;>l:,Jl.«,A$1) 15 l>" L'I-Cv ' (,., '-f I /'-I c:.tJ I~ 16 ~~Elf'(
/itV rt:.. vfrrl. ·~z. I '5 l '+ <u 2 '+ I~
. {"I cv /5" p1,<e/gm 18
lkAS HATH 19 / "5' { '+ c..v •7. L, ' I Pf c.U /5" 20 n, ~ff,';;?,.
{)/NIN~ 21 ~o /2.. c1J '-I ~ ~ 2-, 14 c.v ,s: 22 ~rk"fr ...
23 24
25 26
27 28
29 30
31 32
33 34
35 36
37 38
39 . I 40
41 42
MAIN: D ~ii AMP BRK/FUSE IX MLO Computed Load 7 "I I ":s AMPS
BUS: AMP SH Ca/oulatJon Wori<aheet on bsok
Branch circuits required:
Service 61Tirance or f&&d;~ra: A) L.lghtlng Circuits 220 -3(b), 4(d)
A) Size: No. ;,.., 0 B) Type: CU O AL
C) Insulation: · D) ConduFs--lze: __
B) Two Small Appllance Circuits 210-11(e)
C) Laundry Clrcult 220-16(b)
Service groond/oond:3, /
B) Type: ·~ CU O AL
D) Central Heating Equipment 422-12
A)Stze:No. (:> E) Bathroom 210 -52(d) i Clamp locatlon(s):
UFER 250-50(0) RemarkB:
Watl!Jf Pipe 260-104
0 Ground Rod 250-52
0
~iocat!ons 210-8, 680-70: I cert/ft that till terminations have been torqued In scco,rcJancs wtth manufacturer's
Bathroom(s) ~Kitchen Instructions and that the worl< shown on th!! cJrooft cs.rd representa the full extent of J. Garage{e) . 0Hydroma81!sga Tub the work performoo under thl& permit.
Outdoors D . D OWner
'Protected Clrc.a-12 · '~Contracto~~ ~~ ,....,~d~ ~
Bedroom(s) f;.\J !f!y (,.> H-~£.E D Signed Q = =~ Date : · l 1£5""
B-l PaQe 1 of2 Rev. 03/09
D
' /
2
'W -~
P'.
SINGLE FAMILY DWELLING
ELECTRICAL SERVICE LOAD CALCULATION
As an sltematlve method, the STANDARD METHOD
found In ARTICLE 220 of the National Electric Code, may be used
1. GENERAL L1GHTING LOADS
Dwenlng .:;).. , ,-, 7 sq. ft. X 3 VA::: 220-3(a) ,, 53/ VA
Small appllan~ loads~ 220-16(a) 1500 VA x :.1 circuits== 3, oo() VA
· laundry loa~ -220-16(b )_150.0 VA x circuits = Ii SQQ VA ·
· · General Ughtlng Total I /1 o 3 I VA
2. ·COOKING EQUIPMENT LOADS -Nameplate Value
·Rang9. · ~ · VA= --VA
Cooktop VA= . VA
·Oven (s) VA= VA
· . · · Cooking Equipment Total. ____ VA
3. ELECTRIC DRYER 220-18 (Nameplate, 5000 VA minimum)
D~er -. ·-r-. VA= Dryer.Total __ -____ VA
4. · FIXEJ:) APPLIANCE LOADS 230-30 (b) (3)
Dishwasher =
,P~pqsal =
Compactor=
~tar Heater =
· Hydromassage Bathtub "'
Microwave Oven·=
Built-In Vacuum =
=
5. O_Pi.lONAL SUBTOTAL (Add all of the above totals)
6. APPLYING DEMAND FACTORS-TABLE 220-30 . •',. First 10,000 VA x 100% =
· Optiorial Subtotal (from llne 5) { Remaining .I.../ J / ~ / VA x 40%= L
7. HEATING OR AC LOAD -TABLE 220-30
Larg_er of the Heijtlng or AC Load =
I, s-oo VA
7S0 VA ____ VA
____ VA
--,,-,--~-VA
I J;):CQ VA ____ VA
VA Flxed_Ap_p_ll_an-ce-Total '=,17S0·vA
/If, 7g/ VA I
10,000 VA
('j/'1. VA
~1 000 VA
8. OPTIONAL LOADS TOTAL (Add totals froni lines 6 and 7) = l7/f/~ VA -
9. MINIMUM s.~RVICE SIZE :II Optional Loads Total = 74, 'c3 Ampere
-. . · 240Volt
(Please put total on front of card under Computed Load)
. ' ;•
• I •
J ' I
C,mtlmwus lmpection & Materials 7i,' . .tirl::;
S01UTHVVEST*~~~~~~~~~*~~~~
fospcction & Tesring, Inc.
October 12, 2015
Bullding Official
City of Carlsbad
Department of Building and Safety
1635 Faraday Ave
carjsbad, California 92008
441 Comlnt."fCial Way, La Hal)rn. CA 906.~ 1-6168
{562) 941-2990 • (714) 526,8441
FAX (562) 946-0026
SPECIAL INSPECTOR'S FINAL PROJECT REPORT
l>roject Name: Seagrove Townhomes
Address:
Owner:
state Street, PH 2 Bu1kllng 4
Taylor Morrison
Unit# Address
1 2521,State Street
2 2525 State Street
3 2529'State Street
4 2533 State Street
5 2537 State Street
Permit
CB15043.8
CB150442
CB150446
CB150447
C8150448
Unit# Address
6 2541 State Street
7 2545 State Street
8 2549 state Street
9 2553 State Street
Permit
CB150449
CB150450
CB150451
CB150452
This Is to certify that Southwest Inspection and Testing, Inc. was .employed to perform special inspection on
the above mentioned project at the above address, which required continuous Inspection per section 1701 of
2013 callfornia Building Code.
Brett Alblinger -Reinforced Cdncrete, Post Tensioned Concrete, SD #656
William Bowen -Reinforced Concrete, Post Tensioned Concrete, SD #541
Tom Woods-Reinforced Concrete, Post Tensioned Concrete, SD # 377