HomeMy WebLinkAbout2540 GATEWAY RD; ; CB092130; Permit02-02-2010 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB092130 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: 2540 GATEWAY RD CBAD Tl Sub Type: 2132611500 Lot#: $120,190.00 Construction Type: Reference #: WHITE CONSTRUCTION 3,434 SF SHELL TO OFFICE INDUST 0 5B Applicant: WHITE CONSTRUCTION STE100 5937 DARWIN CT CARLSBAD, CA 92008 760-931-1130 Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Plan Check#: Owner: BRESSI OCEAN COLLECTION L L C C/0 DAVID DIRIENZO 1280 BISON AVE#B9-609 NEWPORT BEACH CA 92660 ISSUED 12/15/2009 JMA 02/02/2010 02/02/2010 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee $722.37 $0.00 $469.54 $0.00 $0.00 $25.24 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $4.00 Meter Size Add'l Reel. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (43041 93) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees HMP Fee TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $2,187.46 $0.00 $0.00 $0.00 $4,663.36 $0.00 $98.00 $60.00 $46.00 $0.00 $2,503.44 $0.00 $0.00 ?? $10,779.41 Total Fees:$10,779.41 Total Payments To Date:$10,779.41 Balanc $0.00 Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 760-602-2717 / 2718 / 2719 Fax 760-602-8558 www.carlsbadca.gov Plan Check No."Z J Est. Value / "2-Q ( *=? Q Plan Ck. Deposit Date JOB ADDRESS CT/PROJECT * 2540 Gateway Rd, Building A LOT#PHASE*# OF UNITS 1 # BEDROOMS SUITE#/SPACE#/UNIT# # BATHROOMS 2 APN TENANT BUSINESS NAME CONSTF White Construction, Inc. V- - . TYPE OCC. GROUP •A B DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) First generation Tl for 3,434 SF of office space EXISTING USE P Cold shell to office space CONTACT NAME (II Different Fom Applicant) ROPOSED USE Office GARAGE (SF) Andrew Dzulynsky ADDRESS 6363 Greenwich Drive, Suite 175 CITY San Dieqo PHONE 858-638-7277 STATE CA ZIP 92122 FAX 858-638-7506 EMAIL ADzulynsky@waremalcomb.com PROPERTY OWNER NAME Greene Properties ADDRESS 1800 ThibodoRd., Suite 320 CITY Vista PHONE 760-727-6888 STATE ZIP CA 92081 FAX EMAIL ARCH/DESIGNER NAME & ADDRESS STATE LIC. # PATIOS (SF)DECKS (SF) 'NAME ADDRESS CITY PHONE EMAIL FIREPLACE YES | |#N(Q AIR CONDITIONING YES | |NO | | FIRE SPRINKLERS YES| |NO[ | White Construction, Inc 5937 Darwin Ct, Suite 100 Carlsbad STATE 760-931-1130 FAX CA ZIP 92008 760-931-1171 ddamron@whiteconstructioninc.com OR BUS. NAME ADDRESS CITY PHONE EMAIL STATE LIC.* White Construction, Inc. 5937 Darwin Ct., Suite 100 STATE Carlsbad 760-931-1130 FAX CA ZIP 92008 760-931-1171 ddamron@whiteconstructioninc.com 452513 CLASS B CITY' BUS. LIC.« 1202380 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires theappHcant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of theBusiness and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: LJ I have and will maintain a certificate of consent to self-insure for workers1 compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued L^J I have and will maintain workers' compensation, as required bv Section 3700 of the Labor Code, for the performance of the work for which this permit is issued My workers' compensation insurance carrier and policy number are: Insurance Co __ HRHrfsinBigo _ PdicyNo. _ Tllliniism _ Expiration Date _ _ oinino This section need not be completed if the permit is for one hundred dollars ($100) or less. I Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING: Failure to secure workers' compensation caveragysylawful. and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100.000), in addition to the cost of compensation, damages as provided for in Section «706W the Labor code, interest and attorney's fees. ^CONTRACTOR SIGNATURE UlUjftlfW fl[ de, interest and at \<\-QAGENT DATE O W N E R- B U I L D E R DECLARATION / hereby affirm that I am exempt from Contractor's License Law for the fb/fovw'ng reason ] I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the builojng or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) J I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with conlractor(s) licensed pursuant to the Contractor's License Law). J lam exempt under Section._Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement I [Yes I |NO 2 I (have / have not) signed an application for a buildmg permit for the proposed work 3 I have contracted with the fdlowing person (firm) to provide the proposed construction (include name address / phone / contractors' license number): 4 I plan to provide portions of the work, but I have hired the fdlowing person to coordinate, supervise and provide the ma|or work (include name / address / phone / contractors' license number): 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address /phone / type of work): PROPERTY OWNER SIGNATURE QAGENT DATE FOR N O N - R E S I D E N T I A L BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business dan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? I I Yes I / iNo Is the applicant or future building occupant required to obtain a permit from the air pollution control district or airguality management dstnct? I lYes f/l No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? I Ires |/|No EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code). Lender's Name Lender's Address APPLICANT I certify that I have read the application and state that the above information is correct and that the info rmatlon on the plans is accu rate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authonze representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA perniit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Offbal under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such pamiitis suspendedorabarKtoriedatanytiiTieatertrewcirkiscomrnenoedforapencidof 180days(Section 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE DATE City of Carlsbad Final Building Inspection Dept: Building Engineering Planning CMWD St Lite Fire Plan Check #: Permit #: Project Name: Address: Contact Person: Sewer Dist: Inspected Bv "~Y} v Inspected Bv Inspected Bv CB092130 WHITE CONSTRUCTION 3,434 SF SHELL TO OFFICE 2540 GATEWAY NA CA v^,^ RD Phone: 7605356200 Water Dist: CA Date j |j Inspected: *2>l Q\ Date Inspected: Date Inspected: Date: Permit Type: Sub Type: Lot: 0 ' i(-/ Approved: V Approved: Approved: 03/09/2010 Tl INDUST '/•' "• Disapproved: Disapproved: Disapproved: Comments: City of Carlsbad Bldg Inspection Request For: 03/10/2010 Permit* CB092130 Title: WHITE CONSTRUCTION Description: 3,434 SF SHELL TO OFFICE Inspector Assignment: TP 2540 GATEWAY RD Lot: Type:TI Sub Type: INDUST Job Address: Suite: Location: APPLICANT WHITE CONSTRUCTION Owner: Remarks: Phone: 760535&200 Inspector: Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By: NA Entered By: CHRISTINE Act Comments Comments/Notices/Holds Associated PCRs/CVs Original PC# PCR07190 ISSUED OCEAN COLL: STRUCT. STEEL; STAIRS CALCULATIONS: BLDG A, B & D PCR07191 ISSUED OCEAN COLLECTION- DEFERRED; FLOOR & ROOF TRUSS PCR07199 ISSUED OCEAN COLLECTION-DEFERRED; STOREFRONT SHOPS AND CALCULATIONS FOR Inspection History Comments T-CLNG SUBPNL CLNG LITES DUCTS Date 02/17/2010 02/17/2010 02/17/2010 02/17/2010 02/09/2010 02/03/2010 02/03/2010 02/03/2010 02/03/2010 Description 14 34 34 44 17 14 24 34 44 Frame/Steel/Bolting/Welding Rough Electric Rough Electric Rough/Ducts/Dampers Interior Lath/Drywall Frame/Steel/Bolting/Welding Rough/Topout Rough Electric Rough/Ducts/Dampers Act AP AP AP AP AP AP AP AP we Insp TP TP TP TP TP TP TP TP TP EsGil Corporation In (Partnership •with government for (BuiCding Safety DATE: 2/2/10 a APPLICANT a JURIS. JURISDICTION: City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 09-2130 SET: III PROJECT ADDRESS: 254O Gateway Rd. Building A Suite 1 PROJECT NAME: White Construction - TI IXI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: XI Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) / Fax #: Mail Telephone Fax In Person REMARKS: Applicant to hand carr ins cHrectly to the City of Carlsbad this does not assure a permit will be issued the cMy May pave other corrections.r TV-t^O J^ By: Doug Moody / Enclosures: EsGil Corporation D GA D EJ D PC LOG 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 """ "EsGil Corporation In (Partnership with government for Quitting Safety DATE: 1/21/10 LLAEPJJCANT JURISDICTION: City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 09-2130 SET: II PROJECT ADDRESS: 2540 Gateway Rd. Building A Suite 1 PROJECT NAME: White Construction - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. XI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: White Construction / Debbie Damron 5937 Darwin Court Suite 100, Carlsbad, CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed. XI Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Debbie Damron Telephone #: 760-931-1 130 ' ' 2 Date contacted: ' I * '//£(by^^ Fax #: 760-931-1171 Mail ^Telephone Fax^^ln Person REMARKS: By: Doug Moody Enclosures: EsGil Corporation D GA D EJ D PC 1/14/10 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576 City of Carlsbad 09-2130 1/21/10 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue. 4. Enclosed usable space under interior or exterior stairways should be protected on the enclosed side as required for one-hour fire-resistive construction. Section 1009.5.3. Please revise the electrical plans to show no lights to be installed in the space under the stairs. 5. Show that accessible lavatories comply with the following, per Sections 1115B.4.3: a) When lavatories are adjacent to a side wall or partition, there shall be a minimum of 18" to the center line of the fixture to the wall. Please revise the plans to show the door to the Men's restroom not to encroach in to the required clear space for the lavatory. Clarify note 7 on sheet A2.1, how will shelves be installed at the lavatory and still be disabled accessible? Please clarify the elevations on sheet A6.1 the women's restrooms is shown to have 2 water closets? To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. City of Carlsbad 09-2130 1/21/10 Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. EsGil Corporation In (Partnership with government for (BuiCcfing Safety DATE: 12/23/O9 JURISDICTION: City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 09-2130 SET: I PROJECT ADDRESS: 2540 Gateway Rd. Building A Suite 1 PROJECT NAME: White Construction - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: White Construction / Debbie Damron 5937 Darwin Court Suite 100, Carlsbad, CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed. XJ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Debbie Damron Telephone #: 760-931-11301 // Date contacted>/?-3/0<f (byj/^ Fax #: 760-931-1171 Mail .^Telephone Fa^/ In Person REMARKS: By: Doug Moody Enclosures: EsGil Corporation D GA D EJ D PC 12/17/09 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 +• (858)560-1468 + Fax (858) 560-1576 . City of Carlsbad O9-213O 12/23/O9 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: O9-213O OCCUPANCY: B TYPE OF CONSTRUCTION: VA ALLOWABLE FLOOR AREA: SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 12/15/09 DATE INITIAL PLAN REVIEW COMPLETED: 12/23/09 JURISDICTION: City of Carlsbad USE: Office ACTUAL AREA: 3434sf STORIES: 2 HEIGHT: OCCUPANT LOAD: 48 DATE PLANS RECEIVED BY ESGIL CORPORATION: 12/17/09 PLAN REVIEWER: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2007 CBC, which adopts the 2006 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2006 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad 09-213O 12/23/O9 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Please clarify the section view of all new interior partitions. Show: a) Method of attaching top plates to structure for wall type B. (Please show the location of the braces on the plans). 2. Please provide sheet A6.3 as referenced in keynote 14 on sheet A2.1. 3. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.3 for the window in office 102 b) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position. And where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. 4. Enclosed usable space under interior or exterior stairways should be protected on the enclosed side as required for one-hour fire-resistive construction. Section 1009.5.3. 5. Please revise the plans to show access to the enclosed usable space (storage 111) shall not be directly from within the stair enclosure. Section 1009.5.3. 6. Please clarify the mechanical plans and the architectural plans to show the roof ladder in the same location and remove the note to remove the ladder Section 904.10.3.3 of the Mechanical Code requires a permanently installed ladder. 7. Please note in the general wiring notes on the plans "AC Cable is not allowed in A, B, E, H, F, M, S and I occupancies. NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible conduits". City of Carlsbad O9-213O 12/23/O9 8. Show that passageways leading to sanitary facilities have required clear access widths, per Section 1115B.5. Show that all doorways have: a) All strike edge clearance dimensions are required to be met (i.e. 18" strike edge distance not 1'2"). 9. Show that accessible lavatories comply with the following, per Sections 1115B.4.3: a) When lavatories are adjacent to a side wall or partition, there shall be a minimum of 18" to the center line of the fixture to the wall. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. City of Carlsbad O9-2130 12/23/O9 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 09-2130 PREPARED BY: Doug Moody DATE: 12/23/09 BUILDING ADDRESS: 254O Gateway Rd. Building A Suite 1 BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VA BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code Rlrln Permit FPP hv OrHinA AREA ( Sq. Ft.) 3434 cb nrp ^ Valuation Multiplier 34.37 By Ordinance Reg. Mod. VALUE ($) 118,027 118,027 it~7A c now lo.uy Plan Check Fee by Ordinance ^ | Type of Review: 0 Complete Review F~l Repetitive Fee Repeats D Other [—I Hourly EsGil Fee Structural Only Hr. @ $464.81 $400.45 Comments: Sheet 1 of 1 macvalue.doc + City of Carlsbad Public Works Engineering BUILDING PLANCHECK CHECKLIST DATE: BUILDING PLANCHECK NO.: CB O?""2^ (<3 OWAV. VW PROJECT DESCRIPTION: T~\ ( ?)i ASSESSOR'S PARCEL NUMBER: V\/Z3- 2J> \ — ENGINEERING DEPARTMENT EST. VALUE: \2-€A APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. D A Right-of-Way permit is required prior to construction of the following improvements: DENIAL Please see the attached report of deficiencies marked with D. Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By: By: By: Date: Date: Date: FOR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT Date: ' ATTACHMENTS D Dedication Application/Checklist D Encina Wastewater Screening Survey D Encroachment Application/Checklist D Final Map (Reference) D Grading Plan Application/Checklist D Improvement Application/Checklist D Neighborhood Improvement Agreement D Right-of-Way Permit Submittal Checklist and Information Sheet D Storm Water Compliance Forms [] Other ENGINEERING DEPARTMENT CONTACT PERSON Name: Linda Ontiveros City of Carlsbad Address: 1635 Faraday Avenue, Carlsbad, CA 92008 Phone: (760) 602-2773 Fax: (760) 602-1052 Email: Linda.Ontiveros@carlsbadca.gov CFD INFORMATION Reference No(s): Lot No.: Recordation: Subdivision/ n . Carlsbad Tract: V\V U(j?- [ ] 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (76O) 602-272O • FAX (76O) 6O2-8562 BUILDING PLANCHECK CHECKLIST ,RD D SITE PLAN 1. Provide a fully dimensioned site plan drawn to scale. Show: A. North Arrow B. Existing & Proposed Structures C. Existing Street Improvements D. Property Lines E. Easements F. Right-of-Way Width & Adjacent Streets G. Driveway widths H. Existing or proposed sewer lateral I. Existing or proposed water service J. Existing or proposed irrigation service D D 2. Show on site plan: A. Drainage Patterns 1. Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. 2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." B. Existing & Proposed Slopes and Topography C. Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project. Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception. D. Sewer and water laterals should not be located within proposed driveways, per standards. 3. Include on title sheet: A. Site address B. Assessor's Parcel Number C. Legal Description For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD DISCRETIONARY APPROVAL COMPLIANCE CD EH 4a. Project does not comply with the following Engineering Conditions of approval for Project No. 4b. All conditions are in compliance. Date: DEDICATION REQUIREMENTS D 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 17.000 . pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 W x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by: Date: IMPROVEMENT REQUIREMENTS D 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ 82.000 . pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by: Date: BUILDING PLANCHECK CHECKLIST -.RD D D IMPROVEMENT REQUIREMENTS continued 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $441 so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as follows: ODD D D 6c. Enclosed please find your Neighborhood Improvement Agreement (NIA). Please return agreement signed and notarized to the Engineering Department. Completed by:Date: 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. D In n n n n n n n n n n GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 15.16.010 of the Municipal Code. 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill import, export). This information must be included on the plans. 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by:Date: 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) 7d .No Grading Permit required. 7e. If grading is not required, write "No Grading" on plot plan. 1ST/ 2ND 3RD BUILDING PLANCHECK CHECKLIST MISCELLANEOUS PERMITS D RIGHT-OF-WAY PERMIT 8. A Right-of-Way permit is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. To see requirements, visit our website: www.carlsbadca.gov/engineering Right-of-Way permit required for: D D INDUSTRIAL WASTE PERMIT 9. If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad of Carlsbad, Development Services Division, located at 1635 Faraday Avenue, Carlsbad, CA 92008. City Staff can provide forms and assistance. You may telephone (760) 602-2750 for assistance D D NPDES PERMIT 10. Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first. D D STORM WATER COMPLIANCE 10a. Q Requires Project Storm Water Permit: PSP Q Tier I/Tier II (Requires SWPPP) - Please complete attached forms ^J No threat -.Ploaoc complete-attached Storm Water Exemption form DEVELOPMENT FEES 11. (^ Required fees-aas-attaehetl Q More information needed Q No fees required BUILDING PLANCHECK CHECKLIST ,ST jRD D WATER METER REVIEW 12a. Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized. Oversized meters are inaccurate during low-flow conditions. If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used. • All single family dwelling units receive "standard" 1" service with 5/8" meter. • All residential units that need to be fire sprinkled receive a 1" meter. See Carlsbad Municipal Code Section 17.04.230 for Automatic fire extinguishing systems criteria. • If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm). Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit. • Maximum service and meter size is a 2" service with a 2" meter. • If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand, (manifolds are considered on case by case basis to limit multiple trenching into the street). NOTE: Upon declaration of Drought Response Level 3 condition, no new potable water service shall be provided and no new temporary meters or permanent meters shall be provided. See Ordinance 44 for more information. n 12b. Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval. The developer must provide these calculations. Please follow these guidelines: • If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets. If so, at the water meter station, the demand in gpm may be listed there. Irrigation services are listed with a circled "I", and potable water is typically a circled "W". The irrigation service should look like: STA1+00 Install 2" service and 1.5: meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach). Typically, the landscape consultant has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use. 6 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD WATER METER REVIEW continued 12b. Irrigation Use (continued) Once you have received a good example of irrigation calculations, keep a set for your reference. In general the calculations will include: • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA). As long as the project is located within the City recycled water service boundary, the City is in the process of switching these irrigation services/meters to a new recycled water line 12c. Irrigation Use (where recycled water is available) Recycled water meters are sized the same as the irrigation meter above. • If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development. For subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge. If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund. However, the City of Carlsbad cannot guarantee the refund. The applicant must deal with the SDCWA for this. 13. Additional Comments: ENGINEERING DEPARTMENT FEE CALCULA TION WORKSHEET D ^Estimate based on unconfirmed information from applicant. Hfl/ Calculation based on building plancheck plan submittal. Address: ^5^ Prepared by : )QO Date: Bldg. Permit No. \V Checked by:Date: EDU CALCULA TIONS: List types and square footages for all uses.CSee VevQ/U* doer Types of Use: COpPl 6€? Sq. Ft./Units: $^3^1 \i &OV EDU's: Sq. Ft./Units: EDU's: _______ Sq. Ft./Units: EDU's: Sq. Ft./Units: EDU's: Types of Use: Types of Use: Types of Use: APT CALCULA TIONS: List types and square footages for all usesie5^ ,.tfFP(6B Sq. Ft./UnitsPj^oCVW) ADT-S: Sq. Ft./Units: ADT's: ADT's: ADT's: SIDE cAuxn_An Types of Use: Types of Use: Types of Use: Types of Use: Sq. Ft./Units: Sq. Ft./Units: FEES REQUIRED. WITHIN CFD: ID'YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) D NO D 1. PARK-IN-LIEU FEE: NW QUADRANT FEE/UNIT: . TRAFFIC IMPACT FEE ADT's/UNITS: NE QUADRANT X NO. UNITS:. FEE/ADT: SE QUADRANT =$ SW QUADRANT D 3. BRIDGE AND THOROUGHFARE FEE (DIST. ADT's/UNITS: X D 4. FACILITIES MANAGEMENT FEE / UNIT/SQ.FT.: ET5. SEWER FEE / 7 -7 'EDU's: ' • £- <-— BENEFIT AREA: H EDU's: 1 ' L^/^ ZONE: X X X #1 DIST. #2 DIST. #3 ) FEE/ADT: = $ FEE/SQ.FT./UNIT: =$ FEE/EDU:\i£^%5' =$ l|3;5'7. f FEE/EDU: 9% =$1,1^^-3^ PLDAD 6. DRAINAGE FEES ACRES: X FEE/AC:_ D 1. POTABLE WATER FEES UNITS CODE CONNECTION FEE METER FEE SDCWA FEE IRRIGATION F \FARMER\KATHV.MASTERS\FEE CALCULATION woRKSHEET.doc20os.doc Rev. 7/14/00 07^ 45,^ PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB092130 DATE 12/15/09 ADDRESS 2540 GATEWAY RD BLDG. A RESIDENTIAL ADDITION- MINOR (<17,000.00) RETAINING WALL VILLAGE FAIRE POOL/SPA TENANT IMPROVEMENT COMPLETE OFFICE BUILDING OTHER PLANNER GINA RUIZ ENGINEER DATE 12/21/09 DATE H:\AD1N\COI)NTER/PUNNINC/ENCINEEH1NC APPROVALS Carlsbad Fire Department Plan Review Requirements Category: TI, INDUST Date of Report: 12-24-2009 Reviewed by: Name: Address: WHITE CONSTRUCTION STE 100 5937 DARWIN CT CARLSBAD, CA 92008 Permit #: CB092130 G. DEPTCOPV~- ••..*.? % Job Name: WHITE: 3434SF SHELL TO OFFICE Job Address: 2540 GATEWAY RD CBAD •^ ._ _... INCOMPLETE I In ill I'll "III! Ill I i||i|jl mUil h ' | | I I ATffii?Hn»rAis4lfi5ce cannot adequately conduct a i n , |n iiliii(i1ll'iiiiiiiiiii|ili mi i \ulli lln ii|ijiliTll'llr ri«i(iUiii .limJjMiliiiKliiiil Mli'llii JM n n carefully all yjpaiflffSattached. Please resubmit the necessary plans and/or specificationsTWi^ch^nges "cloflded", to this office for review and approval. Conditions: Cond: CON0003801 [MET] **** NOTE***** In future submittals, occupant load for conference rooms and the like will utilize 15 as the occupant load factor. ** APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. Entry: 12/24/2009 By: cwong Action: AP STRUCTURAL CALCULATIONS 2K9-410 White Construction Tl Roof Top Mechanical Units Carlsbad, CA Sheets 1 thru 11 PRIME STRUCTURAL ENGINEERS 11858 Bernardo Plaza Court, Suite 105C San Diego, California 92128 Tel (858) 487-0311 '•^r$3 Conterminous 48 States 2005 ASCE 7 Standard Latitude = 33.127807 Longitude = -117.255916 Spectral Response Accelerations Ss and SI Ss and SI = Mapped Spectral Acceleration Values Site Class B - Fa = 1.0 ,Fv = 1.0 Data are based on a 0.009999999776482582 deg grid spacing Period Sa (sec) (g) 0.2 1.109 (Ss, Site Class B) 1.0 0.420 (SI, Site Class B) "A i— ^>Si~^& PR I ME Job: STRUCTURAL Date ErIGiilbERSsht: Conterminous 48 States 2005 ASCE 7 Standard Latitude = 33.127807 Longitude = -117.255916 Spectral Response Accelerations SMs and SMI SMs = Fa x Ss and SMI = Fv x SI Site Class D - Fa = 1.056 ,Fv = 1.58 Period Sa (sec) (g) 0.2 1.171 (SMs, Site Class D) 1.0 0.664 (SMI, Site Class D) Conterminous 48 States 2005 ASCE 7 Standard Latitude = 33.127807 Longitude = -117.255916 Design Spectral Response Accelerations SDs and SD1 SDs = 2/3 x SMs and SD1 = 2/3 x SMI Site Class D - Fa = 1.056 ;Fv = 1.58 Period Sa (sec) (g) 0.2 0.781 (SDs, Site Class D) 1.0 0.443 (SD1, Site Class D) 2K9-410 WHITE CONSTRUCTION HP-1 ROOF MOUNTED MECHANICAL UNITS ASCE 7-05 (13.3.11 PRIME job: STRUCTURAL p*.*- ft/of ENGINEERS sht: V>- ' UNIT Wp 1 Fp1 *,vI CURB ' ' S W = Y = y =x = Y/2 /xl, y s = a = RP = ^ I —P/ -.«-,—z/n — 600.00 42.00 0.00 47.00 0.781 1.00 2.50 1.00 1.00 Ibs. in. in. in. Pd i SEISMIC DEMANDS ON NONSTRUCTURAL COMPONENTS - ASCE 7-05 13.3.1 0.4-ap-Sos-Wp-(1+2-z/h)/(Rp/lp) = 1.6-SDS-IP-WP= Fp 0.3-SDS'IP-WP = 0.2-SDS-Wp = UPLIFT CHECK (ASD) Pe = 0.7-[Fp-(Y/2+y)/X + Fp,v/2] = Based on 50% of Wp Pd = LOADING CHECK (ASD) Based on 67% of Wp Pd = Fp = 0.375 Wn 1.250 WD 0.234 W0 0.375 WD 224.93 Ibs. 0.156 W0 0.172 Wp 0.500 W0 0.172 Wp 0.667 Wp 103.15 Ibs. 300.00 Ibs. (ASCE 7-05 13.3-1) (ASCE 7-05 13.3-2) (ASCE 7-05 13.3-3) > Pe. NO UPLIFT 0.839 Wp/1.33 =0.629 WD PL * LL GOVERNS 2K9-410 WHITE CONSTRUCTION SHP-1 ROOF MOUNTED MECHANICAL UNITS ASCE 7-05 (13.3.1) PRIME Job: STRLfCTURAL Da« Sht: UNIT Wp I Fv i Ifcvt CURB ' ' W = Y = y =x = i72 / SDS = a = RP = (* i - ^ 'P f nz/n = 300.00 40.00 0.00 34.00 0.781 1.00 2.50 1 001 .\J\J 1f\f\.00 Ibs. in. in. in. I j, Pd * ^ J.NDS ON NONSTRUCTURALCOMPONENTS -ASCE7-05 13.3.1 £ SEISMIC DEMANDS ON 0.4-ap-SDS-Wp-(1+2-z/h)/(Rp/lp) = 1.6-SDS-lp-Wp= Fp,max = 0.3-SDS-IP-WP= Fp.min = 0.2-SDS-WP = p —rp P.v ~ UPLIFT CHECK (ASD) P9 = 0.7-[Fp-(Y/2H-y)/X + Fp.v 12} = 0.209 Wp Based on 50% of Wp Pd = 0.500 Wp LOADING CHECK (ASD) Based on 67% of Wp 0.375 Wp 1.250 Wp 0.234 Wp 0.375 Wp 112.46 Ibs. 0.156 Wp 62.71 Ibs. 150.00 Ibs. Pd = 0.209 Wp 0.667 Wpv.ww i p 0.876 Wp 71.33 = 0.657 Wp (ASCE 7-05 13.3-1) (ASCE 7-05 13.3-2) (ASCE 7-05 13.3-3) > Pe. NO UPLIFT PL + LL GOVERNS (3 f STRUCTUR t _!_'r „( a K-* t-*^- NEW 4X @ RTU 21/09 PRIME JOB: STRUCTURAL DATE ENGINEERS SHT: ,OOhl2vOsOb3T (8U (slp!2vlsOb4148TBEAM ANALYSIS PROGRAM (slp9vlsOb4148T SPAN LENGTH = 8.00 ft (Simple Span) (6.43) (8U (sOplO UNIFORM LOADS (k/ft & ft) wd wl XI X2 0.032 0.040 0.00 8.00 POINT LOADS (k & ft) Pd PI X 0.500 0 REACTIONS LOAD Dead Live Total .000 4 (k) LEFT 0.378 0.160 0.538 .00 RIGHT 0.378 0.160 0.538 MAXIMUM FORCES V max = M max = Md max = DEFLECTIONS LOAD Total Live Dead 0.538 k @ 1.576 kft @ 1.256 kft @ (El = kin" Defl (in) 15852/EI 3686/EI 12165/EI 0.00 ft 4.00 ft 4.00 ft 2) X (ft) 4.00 4.00 midspan Pos. Moment Lu = 1.00 ft Brace Spacing = 1.00 ft Gov. Deflection : Total = L/120 Required El = 19814 kinA2 4 x 6 #2 Actual : 3.5" x 5.5' Design per 1991 NDS Douglas Fir-Larch STRESSES (pai) Shear @ 'd' : V = 0.50 k @ 0.46 ft Fv = 95 fv = 39 41 % Fb' = 1136 fb = 1072 94 % Live LDF * 1.00, Cf = 1.30, Cl = 1.00 DEFLECTIONS (in) (E = 1600 ksi) Total = 0.20 Live = 0.05 Dead = 0.16 L /470 L /2022 26 % 9 % STRUCTURAL Date: ENGINEERS sht f - <f 3 x. {, 3B EXIST. 20 TJI (SOB12/15/092K9-370 (slp!2vlsOb4148TBEAM ANALYSIS PROGRAM (slp9vlsOb4148T (6.60) (sOplO .,OOhjL2vOsOb SPAN LENGTH = 26.67 ft (Simple Span) UNIFORM LOADS (k/ft & ft) STRUCTURAL Date: ENGINEERS sht wd 0.128 0 POINT LOADS Pd 0.327 0 REACTIONS LOAD wl XI - X2 .160 0.00 26.67 (k & ft) PI X .000 13.33 (k) LEFT RIGHT Dead 1.870 1.870 Live 2.134 2.134 Total 4.004 4.004 MAXIMUM FORCES V max = M max = DEFLECTIONS LOAD Total Live Dead TOTAL Def 1 L / 180 L / 240 L / 360 LIVE Defl L / 240 L / 360 L / 480 4.00 k @ 0.00 ft 27.79 kft @ 13.33 ft (El = kinA2) Defl (in) X (ft) 3501755/EI 13.33 1821355/EI 13.34 1680400/EI midspan El 1969491 2625988 3938982 El 1365845 2048768 2731691 f [ J H , 3 -^ ',^ < "X ~«,».r-i K-PRIMED- STRUCTURAL _ : -JL- 27,2-5- LU PRIME STRUCTURAL DATS: ENGINEERS SHT: EXIST FLOOR JOIST 12/21/09 .OOhl2vOsOb3T (8U (slp!2vlsOb4148TBEAM ANALYSIS PROGRAM (slp9vlsOb4148T SPAN LENGTH = 17.33 ft (Simple Span) (6.43) (8U (sOplO UNIFORM LOADS (k/ft & ft) wd wl XI X2 0.067 0.107 0.00 17.33 & ft) Pd 0.147 REACTIONS LOAD Dead Live Total PI 0.000 (k) X 8.67 LEFT 0.654 0.927 1.581 RIGHT 0.654 0.927 1.582 MAXIMUM FORCES V max = M max = DEFLECTIONS LOAD 1.58 k @ 7.17 kft @ (El = kinA2) Defl (in) 17.33 ft 8.67 ft X (ft) Total Live Dead TOTAL Defl 380925/EI 8.67 217301/EI 8.67 163624/EI midspan El L / 180 L / 240 L / 360 LIVE Defl 329653 439538 659306 El L / 240 L / 360 L / 480 250736 376105 501473 PRIME Job: STRUCTURAL Date ENGINEERS sht f l' II fSF it - \17 - (^9-- H -- //2. H, EXIST 18 TJI PRIME jQ STRUCTURAL DATE / ENGINEERS SHT: // .OOhl2vOsOb3T (8U (slpl2vlsOb4148TBEAM ANALYSIS PROGRAM (slp9vlsOb4148T SPAN LENGTH = 21.25 ft (Simple Span) (6.43) (8U (sOplO UNIFORM LOADS (k/ft & ft) wd wl XI X2 0.128 0.160 0.00 21.25 POINT LOADS (k S ft) Pd PI X 0.200 REACTIONS LOAD Dead Live Total 0.000 (k) 10.63 LEFT 1.460 1.700 3.160 RIGHT 1.460 1.700 3.160 MAXIMUM FORCES V max = M max = DEFLECTIONS LOAD Total Live Dead TOTAL Defl t / 180 L / 240 L / 360 LIVE Defl L / 240 L / 360 L / 480 3.16 k @ 17.32 kft @ (El = kinA2) Defl (in) 1390418/EI 734071/EI 656346/EI EX 981471 1308628 1962942 El 690891 1036336 1381781 21.25 ft 10.63 ft X (ft) 10.63 10.63 midspan Date 11/30/2009 Project Name White Construction Client/ Purchaser Derek Irwin Order No. Submittal Summary Page (Equipment Only. Refer to Quotation Page or Schedules for Selected Accessories) Qtv Tag #Model #Description B2HZ060A25 Single Package Heat Pumps (Air Cooled), 2nd Generation, R-410a 13 SEER, 5 Ton, No Electric Heat Installed, 208/230-3-60 THGD60S43S1 Heat Pump, Wire Guard, 13 SEER, 5 Ton, Single, R-410A, 208/230-3-60, Sweat Connection, 1st Generation F6FP060H06T3X Single Piece Air Handler, 6th Generation, X13 Motor, 5 Ton, Horizontal Drain Pan Installed, 208/230-1-60, TXV Required, Flex Coil, No TXV Factory Installed S1-1TVM4K1 Latitude TXV Unit Unitary Sales Tool vl 4.10.0 Information is subject to change without notice. Check local codes.Printed 12/10/2009 SIYORK Affinity BHZ -13 SEER Single Pkg. R-410A HP Date: 11/30/2009 Page: 3 Order No: Project Name: White Construction Purchaser: Derek Irwin Model #: B2HZ060A25 Quantity: 1 Tag*:System: B2HZ060A25 BHZ024-060 AFFINITY UNIT DIMENSIONS HIGH VOLTAGE CONN. 7/8" DIA. KNOCKOUT FRONT HIGH VOLTAGE CONN. 1-31/32" DIA. KNOCKOUT LOW VOLTAGE CONN. 7/8" DIA. KNOCKOUT SIDE SUPPLY AIR OPENING SIDE RETURN AIR OPENING COMPRESSOR SERVICE ACCESS COMPARTMENT PANEL REFRIGERANT CONNECTIONS EUECTRICAUFILTER SERVICE ACCESS COMPARTMENT PANEL HIGH VOLTAGE CONN. 1-23/64" DIA. KNOCKOUT 4-1/2 UNIT CONDENSATE CONNECTION 3/4" NPTI (TRAP REQUIRED) UNIT SIZE 024-036 042-060 DIMENSION "A" 331/2 411/2 Unitary Sales Tool vl.4.10.0 Information is subject to change without notice. Check local codes.Printed 12/1072009 aYORK Affinity BHZ -13 SEER Single Pkg. R-410A HP Date: 11/30/2009 Page: 5 Order No: Project Name: White Construction Purchaser: Derek Irwin Model #: B2H2060A25 Quantity: 1 Tag#:System: B2HZ060A25 BHZ024-060 AFFINITY UNIT DIMENSIONS - BACK & BOTTOM SIDE SUPPLY AIR OPENING CONDENSER COIL BOTTOM SUPPLY AIR OPENING BACK 3-3/B SIDE RETURN /AIR OPENING BOTTOM RETURN AIR OPENING Unilaiy Sales Tool vl.4.10.0 Information is subject to change without notice. Check local codes.Printed 12/10/2009 liYOHC Latitude York THGD 018 - 060 Split System HP, 13 SEER Date: 11/30/2009 Order No: Page: 7 Project Name: White Construction Purchaser: Derek Irwin Model #:THGD60S43S1 Quantity: 1 Tag*:System: THGD60S43S1. F6FPQ60H06T3X, S1-1TVM4K1 THGD R-410a 3ph Dimensions, Typical Installation and Wiring All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request Unit Model 030 036 042 048 060 Dimensions (Inche.) A' 36 40 40 40 40 B 34 34 34 34 34 C 34 34 34 34 44"" Refrigerant Connection Swvic* V«lv» Sin Liquid W Vapor 7/8' 1. Including Fan Guard. TYPICAL INSTALLATION M»ilMUU2<-SiB«Ce XT CLEARANCE AROUNO PERMETER NOTE: AU. OUTDOOR VVIRKG MUST B£ WEATHERPROOF. TO FURNACE ORAW HANDLER TERMINAL BLOCK NEC CLASS 2 WIRING TOINOCOROOl P^RMAGUU OR EQUIVAl£tn TYPICAL FIELD WIRING ALL FIELD WIRWG TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES THERMOSTAT INDOOR UNITE TSMMU. B.OO( OUTDOOR UNIT DEFROST CONTROL ' JUMPER TERM JIALS EWD WTO HEATON F«3T STAGE DURING E1CROENCV HEAT. ^TERUMAi NOT USED ON ALL THERMOSTATS. — — - POWER WRING2+V CONTROL WRING (NEC CLASS 2) 1 CHECK THE LOWVCLTAGE TERHHAL BLOCK ON THE INOOOR UNIT FOR THE ACTUAL ARRANCEUENT OF THE TERM»IAL&4 CONNECT POWER WRINQ TO TERMNAL BLOCK 3TB ON UNITS WITHOUT ELECTRIC HEAT OR CRCLNT8R£AKER ' GRAY FOR USE WITH OPTIONM. OUTDOOR THEW.IOSTAT KITS. Unitary Sales Tool v1 4.10.0 Informalion is subject 10 change without notice. Check local codes.Printed 12/10/2009 ii^YORK Project Name: White Construction Purchaser: Derek Irwin Quantity: 1 Tag #: DIMENSIONS / SHIPPING BRACKE REMOVE PRIOR-- TO INSTALLATION (2 SCREWS) 10 *T^- \ DRAIN CONNECTIONS- v FOR HORIZONTA APPLICATIONS VAPOR 41 OPENING--^. LIQUID ~F~-\ OPENING 1 — t D tL 2-J ~>i-1 DRAIN "^ ' CONNECTIONS- ! FOR UPR.OW | APPLICATIONSI Dimensions Model1 F6FP013HOST" F6FP024H06T" F6FP030H06T" F6FP036H06T" F6FP042H06T" F6FP048H06T" F6FP060H06T" York Date: 11/30/2009 Page: 9 Single Piece Air Handler for use with Order No: Split-System Model #: F6FP060H06T3X System: THGD60S43S1, F6FP060H06T3X, S1-1TVM4K1 F6FP Dimensions ILL DIMENSIONS ARE IN INCHES AND ARE SUBJECT TO CHANGE WITHOUT NOTICE CERTIFIED DIMENSIONS WILL BE PROVIDED UPON REQUEST. 1 1CW/87\rt A~ 21-19/32 . / ^=¥==§3 •3»*i^^r=5U, x- a sa ^53 Models 01 # V FILTER ACCES, 8-043 f 3/4 r-F-^ MW j-T^gGliS:^ A JB^=DRAIN PAN FOOTPRINT > MAX F8.TER LENGTH >— ^_^_ / (21 INCHES) ^~"~— -~, MAX. FILTER WIDTH Q (B MINUS 1,1/2 INCHES) flt^ *n*3i& ** 3 ^^ BOTTOM VIEW ^ 24-1^^^/~-^- Model 060 61 V 23-1/2 BOTTOM OPENING Refrigerant Dimensions Wiring K.O.s2 Connections Line Size A Height 40-3/4 40-3/4 40-3/4 40-3/4 50-3/4 50-3/4 61 B Width 18 18 21-1/2 21-1/2 24 24 24-1/2 C JD E FDepth Power 14-7/8 16-1/2 1?1/JJ 14-7/8 16-1/2 7/8(1/2) 18-3/8 20 1-3(8(1)22 18-3/8 20 20-7/8 22-1/2 7/fl(l.?l 17-3/a 20-7/8 22-1/2 1-3/80) 21-1/2 23-1/2 21-19/32 K Control 5/8 3/4 3/4 7/8(1/2) 3/8 7/8 7/8 7/8 7/8 1. All models only available with factory installed horizontal drain pan. 2. Actual conduit size is shown in parenthesis. Unitary Sales Tool vl.4.10.0 Information is subject to change without notice. Check local codes.Printed 12/10/2009 ilYORK York Single Piece Air Handler for use with Split-System Date: 11/30/2009 Page: 11 Order No: Project Name: White Construction Purchaser: Derek Irwin Model*: F6FP060H06T3X Quantity: 1 Tag #:System: THGD60S43S1, F6FP060H06T3X, S1-1TVM4K1 F6FP Typical Wiring FIELD WIRING CONNECTION - COOLING ONLY FIELD WIRING CONNECTION - WITH HEATER KIT OUTDOOR UNIT THERMOSTAT FAN COIL UNIT 6600000 R Y G W2 W1 O C THERMOSTAT [Wj-- col UNIT 6OOO R Y G W2 W1 O C 'NOT REQUIRED ON2 OR 5KW FIELD WIRING CONNECTIONS - COOLING MODELS WITH ELECTRIC HEAT WIRING Air Handler Control Wiring Typical A/C - Cooling only Applications THERMOSTAT BOARD 1 - STAGE R G Y W1 W2 C — R G Y'Y2 Y1 W2 W1 O HUM X/L COM AIR CONDITIONING j y ] HUMIDISTAT | 1 ci Air Handler Control Wiring Typical A/C with Electric Heat Applications THERMOSTAT 1- STAGE R G Y W2 W1 C R G Y/Y2 Y1 W2 W1 O HUM X/L COM AIR CONDITIONING ^J : 1 C HUMiDISTAf ' Dehurnidification control connection CHumldistat" lumper on CFM selection board must be removed). FIELD WIRING CONNECTIONS - SINGLE STAGE HEAT PUMP THERMOS G Y W2 E W/W1 O X/L C CO AndNsv Single Staga HIP «r AIRTAT r NTROL nrllPGrthStan [HAND BOARD R G Y/Y2 Y1 W2 Wt O HUM X/L COM WIRING -Air Handle Single Stage HP Sy dard Demand Dofro JHR r stem* st Control Board HE I 1 HUMIOISTAT* ATPUtu r~R~~i Y W166 W 0 X/L_ , IP • Oehumidihcation control connection i'Humidislal' jumper on CFM selection board must ba removed). NOTES: 1. "Y" Terminal on Air Handler Control Board must bo connected foe full CFM and applications requinng 60 second Blower Off Delay for SEER enhancement. 2. Optional Dehumidiftcation Humidlstat contacts open on rise. 3. For F4FV model • Remove Humidistat Jumper on CFM Selection Board - if used. 4. For F4FV modal - For Heal Pump Applications - Remove Heal Pump Jumper on CFM Selection Board. 5. To change quantity of heat during HP defrost cycle - Reverse connections at W1 ond W2 on Air Handler Control Boord. Unitary Sales Tool v1.4.10.0 Information is subject lo change without notice. Check local codes.Printed 12/10/2009 Page 8 of 18 ESR-1153 TABLE 3—PROPERTIES FORTJI JOISTS BASIC PROPERTIES Joist Depth (in.) Joist Weight (Pit) Resistive Moment (ft.-lbs.) (10) Vert. Shear (Ibs.) El x106 bs.-in.2 K REACTION PROPERTIES END REACTION (Ibs.) 1-3/4" 2-1/2" (9) Bearing Length Web Stiffeners NO YES 3-1/2" Bearing Length Web Stiffeners NO YES Nails Req'd for Web Stiff. INTERMEDIATE REACTION (Ibs.) 3-1/2" 5-1/4" (7) Bearing Length Web Stiffeners NO YES 5-1/4" 7" (7) Bean'ng Length Web Stiffeners NO YES Nails Req'd for Wph Stiff TJ1 110 9-1/2 11-7/8 14 2.3 2.5 2.8 2380 3015 3565 1220 1560 1860 140 238 351 4.5 4.5 4.5 885 885 885 NA 1225 1225 1220 1350 1350 NA 1560 1705 NA 3-8d 3-8d 1935 1935 1935 NA 2295 2295 2350 2350 2350 NA 2705 2705 NA 3-8d 3-8d TJI 210 9-1/2 11-7/8 14 16 2.6 2.8 3.1 3.3 2860 3620 4280 4895 1330 1655 1945 2190 167 283 415 566 4.5 4.5 4.5 4.5 980 980 980 980 NA 1340 1340 1340 1330 1435 1435 1435 NA 1655 1790 1790 NA 3-8d 3-8d 3-8d 2145 2145 2145 2145 NA 2505 2505 2505 2565 2565 2565 2565 NA 2925 2925 2925 NA 3-8d 3-8d 3-8d TJI 230 9-1/2 11-7/8 14 16 2.7 3.0 3.3 3.5 3175 4015 4755 5440 1330 1655 1945 2190 183 310 454 618 4.5 4.5 4.5 4.5 1035 1035 1035 1035 NA . •1395J 1395 1395 1330 ' 1460 1460 1460 NA 1655 1815 1815 NA 3-8d 3-8d 3-8d 2410 2410 2410 2410 NA 2765 2765 2765 2790 2790 2790 2790 NA 3150 3150 3150 NA 3-8d 3-8d 3-8d TJI 360 9-1/2 11-7/8 14 16 18 20 2.7 3.0 3.3 3.5 3.7 4.0 4790 6180 7335 8405 9465 10515 1425 1705 1955 2190 2425 2660 249 419 612 830 1085 1376 4.5 4.5 4.5 4.5 4.5 4.5 1080 1080 1080 1080 1080 1080 NA 1440 1440 1440 1440 1440 1425 1505 1505 1505 1505 1505 NA 1705 1865 1865 1865 1865 NA 3-8d 3-8d 3-8d 3-8d 3-8d 2460 2460 2460 2460 2460 2460 NA 2815 2815 2815 2815 2815 3000 3000 3000 3000 3000 3000 NA 3360 3360 3360 3360 3360 NA 3-8d 3-8d 3-8d 3-8d 3-8d TJI 560 9-1/2 11-7/8 14 16 18 20 3.6 4.0 4.2 4.5 4.8 5.1 7355 9500 11275 12925 14550 16165 1670 2050 2390 2710 3030 3345 378 636 926 1252 1631 2064 5.3 5.3 5.3 5.3 5.3 5.3 1265 1265 1265 1265 1265 1265 NA 1740 1740 1740 1740 1740 1670 1725 1725 1725 1725 1725 NA 2050 2200 2200 2200 2200 NA 3-16d 3-1 6d 3-1 6d 3-1 6d 3-1 6d 3000 3000 3000 3000 3000 3000 NA 3475 3475 3475 3475 3475 3455 3455 3455 3455 3455 3455 NA 3930 3930 3930 3930 3930 NA 3-16d 3-1 6d 3-1 6d 3-1 6d 3-1 6d TJI L65 9-1/2 11-7/8 14 16 18 20 22 24 26 28 30 3.0 3.3 3.6 3.9 4.2 4.4 4.7 5.0 5.3 5.5 5.8 5215 6750 8030 9210 10380 11540 12690 13830 14960 16085 17205 1675 1925 2125 2330 2535 2740 2935 3060 2900 2900 2900 263 450 666 913 1205 1545 1934 2374 2868 3417 4025 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 1375 1375 1375 1375 1375 NA NA NA NA NA NA NA 1745 1750 1750 1750 1750 1750 1750 1750 1750 1750 1675 1885 1885 1885 1885 NA NA NA NA NA NA NA 1925 2125 2330 2535 2740 2935 3060 2900 2900 2900 NA 3-8d 5-8d 6-8d 7-8d 8-8d 9-8d 10-8d 11 -8d 12-8d 13-8d 2745 2745 2745 2745 2745 NA NA NA NA NA NA NA 3120 3365 3490 3615 3740 3860 3875 4725(7) 4850(7) 4975(7) 3365 3365 3365 3365 3365 NA NA NA NA NA NA NA 3735 3985 4105 4230 4355 4480 4605 5345(7) 5470(7) 5590(7) NA 3-8d 5-8d 6-8d 7-8d 8-8d 9-8d 10-8d 11-8d 12-8d 13-8d See notes at the end of the table. Page 9 of 18 ESR-1153 TABLE 3-CONTINUED BASIC PROPERTIES Joist Depth (in.) Joist Weight (plf) 91/2 11-7/8 14 16 18 20 22 24 26 28 30 3.8 4.2 4.5 4.7 5.0 5.3 5.6" 5.8 6.1 6.4 6.6 Resistive Moment (ft.-lbs.) (10) Vert. Shear (Ibs.) 7415 9605 11430 13115 14785 16435. .. f8075 19700 21315 22915 24510 1675 1925 2125 2330 2535 2740 2935 3060 2900 2900 2900 El X108 lbs.-in.2 K REACTION PROPERTIES END REACTION (Ibs.) 1-3/4" 2-1/2" (9) Bearing Length Web Stiffeners NO YES 3-1/2" Bearing Length Web Stiffeners NO | YES Nails Req'd for \A/aKVV6D Stiff. INTERMEDIATE REACTION (Ibs.) 3-1/2" 5-1/4" (7) Bearing Length Web Stiffeners NO YES 5-1/4" 7" (7) Bearing Length Web Stiffeners NO YES Nails Req'd for \A/Ah Stiff. TJI L90 365 621 913 1246 1635 2085 2597 3172 3814 4525 5306 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 1400 1400 1400 1400 1400 NA NA NA NA NA NA NA 1715 1875 2030 2030 2190 2345 2345 2450 2450 2450 1675 1885 1885 1885 1885 ..NV NA NA NA NA NA NA 1925 2125 2330 2515 . ^l5-' 2830 2830 2900 2900 2900 NA 2-1 6d 3-1 6d 4-1 6d 4-1 6d -5^1 6d_, 6-1 6d 6-1 6d 7-1 6d 8-1 6d 8-1 6d 3350 3350 3350 3350 3350 .^NA NA" NA NA NA NA NA 3665 3825 3980 3980 4140 5090 5405 5800(7) 5800(7) 5800(7) 3965 3965 3965 3965 3965 NA NA NA NA NA NA NA 4285 4440 4600 4600 4755 5705 6020 5800(7) 5800(7) 5800(7) NA 2-1 6d 3-1 6d 4-1 6d 4-1 6d 5-1 6d 11-16d 13-16d 14-16d 15-16d 17-16d TJI H90 11-7/8 14 16 18 20 22 24 26 28 30 4.6 4.9 5.2 5.4 5.7 6.0 6.3 6.5 6.8 7.1 10960 13090 15065 17010 18945 20855 22755 24645 26520 28380 1925 2125 2330 2535 2740 2935 3060 2900 2900 2900 687 1015 1389 1827 2331 2904 3549 4266 5059 5930 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 1400 1400 1400 1400 NA NA NA NA NA NA 1715 1875 2030 2030 2190 2345 2345 2450 2450 2450 1885 1885 1885 1885 NA NA NA NA NA NA 1925 2125 2330 2515 2675 2830 2830 2900 2900 2900 2-1 6d 3-1 6d 4-1 6d 4-1 6d 5-1 6d 6-1 6d 6-1 6d 7-16d 8-16d 8-1 6d 3495 3495 3495 3495 NA NA NA AM NA NA 3810 3970 4130 4130 4285 5235 5425 5800(7) 5800(7) 5800(7) 4100 4100 4100 4100 NA NA NA NA NA NA 4420 4575 4735 4735 4890 5840 6155 5800(7) 5800(7) 5800(7) 2-1 6d 3-1 6d 4-1 6d 4-1 6d 5-1 6d 11-16d 13-16d 14-16d 15-16d 17-16d TJI HD90 11-7/8 14 16 18 20 22 24 26 28 30 32 11-7/8 14 16 18 20 22 24 26 28 30 32 5.4 5.7 6.0 6.3 6.7 7.0 7.3 7.6 7.9 8.2 8.5 6.0 6.3 6.6 7.0 7.3 7.6 7.9 8.2 8.5 8.8 9.1 14075 16920 19550 22150 24725 27280 29815 32330 34830 37310 39785 2320 2565 2790 3020 3250 3480 3710 3940 4165 4375 4375 826 1232 1695 2239 2866 3579 4380 5272 6258 7339 8519 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 1835(9) 1835(9) 1835(9) 1835(9) NA NA NA NA NA NA NA 2320(9) 2565(9) 2790(9) 3020(9) 3250(9) 3475(9) 3500(9X11, 3500(9)(11, SSOWHH, 3500(9)(11, 3500(9)(11t 2150 2150 2150 2150 NA NA NA NA NA NA NA 2320 2565 2790 3020 3250 3480 3710 3940 4165 4375 4375 4-16d 6-1 6d 6-1 6d 8-1 6d 10-16d 10-16d 12-16d 14-16d 14-16d 16-16d, 18-16d 3995 3995 3995 3995 NA NA NA NA NA NA NA 4650 4980 4980 5310 5425 5425 5425 6985(7) 6985(7) 7310(7) 7640(7) 4690 4690 4690 4690 NA NA NA NA NA NA NA 5345 5670 5670 6000 6330 6330 6655 7675(7) 7675(7) 8005(7) 8335(7) TJI HS90 16050 19425 22550 25640 28695 31725 34730 37715 40680 43630 46560 2320 2565 2790 3020 3250 3480 3710 3940 4165 4375 4375 900 1355 1876 2488 3195 3998 4901 5905 7014 8230 9555 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 1835(9) 1835(9) 1835(9) 1835(9) NA NA NA NA NA NA NA 2320(9) 2565(9) 2790(9) 3020(9) 3250(9) 3475(9) 1500(9)(11, JSOOfStfJf; 1500(9)(11) 1500(9)(11) 1500(9)(11, 2150 2150 2150 2150 NA NA NA NA NA NA NA 2320 2565 2790 3020 3250 3480 3710 3940 4165 4375 4375 4-1 6d 6-1 6d 6-1 6d 8-1 6d 10-16d 10-16d 12-16d 14-16d 14-16d 16-16d 18-16d 3995 3995 3995 3995 NA NA NA NA NA NA NA 4650 4980 4980 5310 5425 5425 5425 6985(7) 6985(7) 7310(7) 7640(7) 4690 4690 4690 4690 NA NA NA NA NA NA NA 5345 5670 5670 6000 6330 6330 6655 7675(7) 7675(7) 8005(7) 8335(7) See notes at the end of the table. 4-1 6d 6-1 6d 6-1 6d 8-1 6d 10-16d 10-16d 12-16d l4-16d 14-16d 16-16d 18-16d 4-16d 6-1 6d 6-1 6d 8-1 6d 10-16d 10-16d 12-16d 14-16d 14-16d 16-16d 18-16d Page 10 of 18 ESR-1153 TABLE 3— CONTINUED BASIC PROPERTIES Joist Depth (in.) Joist Weight (plf) Resistive Moment (ft.-lbs.) (10) Vert. Shear (Ibs.) El x10s Ibs.-in.2 K REACTION PROPERTIES END REACTION (Ibs.) 1-3/4" 2-1/2" (9) Bearing Length Web Stiffeners NO YES 3-1/2" Bearing Length Web Stiffeners NO YES Nails Req'd for Web Stiff. INTERMEDIATE REACTION (Ibs.) 3-1/2" 5-1/4" (7) Bearing Length Web Stiffeners NO YES 5-1/4" 7" (7) Bearing Length Web Stiffeners NO YES Nails Req'd for Web Stiff. TJI 100C 91/2 11-7/8 14 16 2.5 2.7 3.0 3.2 2605 3350 3915 4430 1120 1420 1710 1970 184 314 461 628 4.5 4.5 4.5 4.5 1120 1125 1125 1125 NA 1420 1480 1480 1120 1405 1405 1405 NA 1420 1710 1760 NA 3-8d 3-8d 3-8d 2285 2285 2285 2285 NA 2640 2640 2640 2795 2795 2795 2795 NA 3155 3155 3155 NA 3-8d 3-8d 3-8d TJI 300C 11-7/8 14 16 2.7 3.0 3.2 4470 5355 6085 1420 1710 1970 372 545 742 4.5 4.5 4.5 1125 1125 1125 1420 1480 1480 1405 1405 1405 1420 1710 1760 3-8d 3-8d 3-8d 2595 2595 2595 2950 2950 2950 3175 3175 3175 3535 3535 3535 3-8d 3-8d 3-8d For SI: 1 inch = 25.4 mm, 1 plf = 14 59 N/m, 1 ft.-lb. = 1 .356 N-m, 1 Ib.-in." = 2.87 kN-mm.' FOOTNOTES FOR TABLE 3: 1. Refer !o Figure 1 for web stiffener details. 2. Deflection is calculated as follows: Uniform load: A =22.5WL4 12WL2 El KdxIO5 Concentrated toad at midspan :A =36PLJ El 24PL KdxIO5 Where: P = Concentrated load, pounds. W = Uniform load in pounds per lineal foot. d = Out-to-out depth of joist, inches. L = Clear span in feet El = From table. K = From table. 3. The stated allowable design properties are for loads of normal duration. Adjustments to the allowable design values must be in accordance with the applicable code, with the exception noted in footnote 10 below. 4. Interpolation between bearing lengths and joist depths is permitted for allowable design reactions. 5. The minimum bearing length is permitted to be reduced for joists supported by hangers if supplemental nail attachment is provided to the web stiffener. 6. Allowable bearing lengths have been determined based on Weyerhaeuser TJI Joist products. Allowable bearing on supporting members must be checked. 7. Allowable bearing reactions for 5-1/4-inch and 7-inch bearing lengths at intermediate supports. 8. Joist weights shown are calculated on a rational basis, are based on the heavier of eastern or western species products and are suitable for dead load calculation. Contact the producing plant for shipping weight information if needed. 9. Applicable to TJI HD90 and TJI HS90 joists only. Areas indicate allowable bearing reactions for a 2-1/2 inch bearing length at end supports. 1-3/4 inch end bearing lengths are also permitted; with allowable reactions of 1600 Ibs. without web Stiffeners for depths up to and including 18 inches; with web Stiffeners the allowable reaction is 2255 Ibs. for the 11-7/8 inch depth and 2450 Ibs. for all other depths. 10. The resistive moment capacities listed in Table 3 may not be increased by any code allowed repetitive-member use factor. 11. Applicable to TJI HD90 and TJI HS90 joists only. Reaction capacities based on applicable hanger seat length (interpolated as per note 4 above) may be increased 510 Ibs when supported by Simpson Strong-Tie Co. HWI or WPU joist hangers with a minimum of 4 10d common nails installed through the joist hanger stirrups and into the joist web stiffener and web. TABLE 4— PROPERTIES FOR USE IN SECTION 4.2 TJI JOIST SERIES rjmo TJI 210, TJI 230 HI 360 TJI 560 TJI 100C, TJI 300C rjj L65. TJI L90. TJI H90 rjl HD90, TJI HS90 TJI JOIST DEPTH (Inches) £14 £16 £16 £20 £16 £24 £24 Vl2 (Ibs.) 1,560 1,655 1,705 2,050 1,420 1,925 2,320 K 15.60 16.55 17.05 20.50 14.20 r 19.25 23.20 For SI: 1 inch = 25.4 mm. i ID. = 4.448 N, 1 plf = 14.59 N/m. TITLE 24 REPORT Title 24 Report for: White Construction Office 2540 Gateway Road, Bldg. A, Unit 1 Carlsbad, CA Project Designer: Ware Malcomb Report Prepared By: Michael Dell DELL CO. 1629 York Drive Vista, CA 92084 (760) 940-0064 Job Number: NR12-89 Date: 12/9/2009 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySofl Job Number: NR12-89 User Number: 1712 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form MECH-1 -C Certificate of Compliance 3 Form MECH-2-C Air & Water System Requirements 5 Form MECH-3-C Mechanical Ventilation 7 Form MECH-4-C HVAC Misc. Prescriptive Requirements 8 Form MECH-MM Mechanical Mandatory Measures 10 HVAC System Heating and Cooling Loads Summary 12 EnergyPro 4.4 by EnergySoft Job Number: NR12-89 User Number 1712 [CERTIFICATE OF COMPLIANCE (Part 1 of 2) MECH-l-C UDJECTNAIC PHUECT ADDtSS PRINCIPAL HSIUCR - t UJUHNIAIUfl NJIHK White Construction Office 2540 Gateway Road, Bldg. A, Unit 1 Carlsbad Vest Air Mechanical DELL CD. TOEPHK 1QBWC(760) 940-0064 DATE 12/9/2009 1UdngPmftt 1 Checked by/late Ehf orcnait Agency 1 | bENEM. 1NHRHATIDN DA1E J PLANS 12/0 9 HJUDNG CDtlllWl FUbt AREA 3,248 So/t CUMA1E ZONE 7 BUUHNG TYPE NDNRESDBfflAL a HUM RISE REsnonw.mEL/ima GUEST RD» PHASE ir CONSTRUCT™NFV OHSTRUCTIDN D DAL1ERATHM uNoranna (He Affidavit) ODD OF ICCHANEAL COHFUANCE PRESCRIPTIVE PERFORHANCE PROOF J ENVELOPE CDfUANCE PREVIOUS ENVEUFE PERMIT ENVELOPE COHFUANCE ATTAOO STATEMENT IF UBPUANCE llis Certificate of L'onpllance lists the bulling fenfires ana perfornance specifications needed to conply rith litle a, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to bulling nechanlcal requirenents. The docunentatlon preparer hereby certifies that the docunentatlon Is accurate and canplete. ULUUMAIUJN AUIHK SILNAlUt Michael Dell 12/9/2009 The Principal Mechanical Designer hereby certifies that the proposed buKdng design represented ki this set of construction docunents is consistent with the other conpliance forns and worksheets, nth the specifications, and with any other calculations subnitted with this perntt application. The proposed butting has been designed to neet the nechanlcal requtenents contained In the applicable parts of Sections 100,101,102,110 throughll5,120 through 125,142,144, and 145. U] The plans I spedffcatfcns neet the requhnents of Part 1 (Sections UHlBaX [J] The hstallatfcn certificates neet the requrenents of Part 1 <HH03a 3). fXl The operation t nahtenance Mornatlon neets the requrenents of Part 1 (10-103cX Please check one: (These sectonsof the Dushess and Professions Code are prhted h fuU In the NorresHentto NanuaL) [—j I hereby affhi that I an etlgWe under the provisions of DMstan 3 of the Business and Professions Code to sign this docuwnt as the — person responstte for Its preparation) and that I an licensed In the State of California as t dvl engheer, or nechanlcal engheer or I ana tensed arcHtect nn I affirn that I an edoWe wder the exenptbn to DMstoi 3 of the lushess and Professions Code by Section 55372 or 6737.3 to sign '—' this docifient as the person responsfcte for Its preparotioni and that I an a licensed contractor perforahp, this iork. |—| I affirn that I an ellofcle into- the exenpHon to DMshn 3 of the Buskiess and Professions Code to sign thb docunent because It pertains to a '—' structure or type of iork descrbed pursuant to Business and Professions Code sections 5537, 5538, and 67371 ttDCPAL HECHAMCAL DESIGNER - NANE West Air Mechanical INSTRUCTDHS ID flPPLlCANT Air/Vater/Servlce/Vater Pools Requk-enents. Part 1 of 3, 2 of 3, 3 of 3 are requt-ed for all subntttals, but nay be on plans. GDMECH-1-G Certificate of Conpliance. Part L 2, 3 of 3 are requted on plans for all subnrttals EMECH-2-C. rHHECH-3-0 Mechanical Ventilation and Reheat Is requted for all subrtttals ilth nechanlcal ventXation, but nay be on plans. fjrjMECH-4-Ci HVAC Mbc Prescriptive Requirenents Is requted for all preserve subnittals, but nay be on plans. 3MECH-5-& Mechanical Equipnent letals are required for all perfornance subnittals, EnergjProM by EnergySoft User Nuiben 1712 JobHutan M92-89 Pip 3 of 13 CERTIFICATE OF COMPLIANCE (Part 2 of 2) MECH-1-C PROJECT NAME White Construction Office DATE 12/9/2009 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space-conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-1-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of Section 10-103(b) and Title 24 Part 6. STATEMENT OF COMPLIANCE I I MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring arreptanr.fi testing Test required on all New systems both New Construction and Retrofit. Q MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring anrnptanrfi testing fe.sf required on all New systems both New Construction and Retrof*. O MECH-4-A: Air-Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the commission do not require equipment testing but do require construction inspection. EH MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing 77iis test required If the unit serves 5, 000 ft2of space or less and 25% or more of the ducts are in nonconditioned or seniconditioned space lite an attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or replace the packaged unit. \ I MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing AllnewDCV controls installed on new or existing packaged systems must be tested. EH MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing Alt newVAV fan volume controls installed on new or existing systems must be tested [U MECH-8-A: -Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chlled and hot water systems. -Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header. -Supply Water Temperature Reset Controls Applies to new constant How chilled and hot water systems that have a design capacity greater than or equal to 500,000 8tu/hr. -Water-loop Heat Pump Controls Applies to all new waterfoop heat pump systems where the combined loop pumps are greater than 5 hp. -Variable Frequency Controls Applies to all new distribution pumps on new variable How chilled, hydronic heat pump or condenser water systems where the pumps motors are greater than 5 hp. Equipment requiring acceptance testing EnergyPro 4.4 by EnergySoft User Number: 1712 Job Number: NR12-89 Page:4of13 I AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C PROJECT NAME White Construction Office DATE 12/9/2009 ISYSTEM FEATURES AIR SYSTEMS, Central or Single Zone HVAC SHP-1 5 ton 1st Roor HVAC HP-2 5 ton 2nd Floor T-24 Section Reference on Plans or Specification ' 112(a) 112(a) 112(b) 112(c), 115(a) 121(b) 121(b) 121(c) 121(c) 121(c), 122(6) 122(e) 122(0 122(g) 123 124 7.30 HSPF 13.0 SEER /11.0EER Yes n/a Yes 326 cfm No No Programmable Switch No Setback Required Auto n/a R-4.2 7.70 HSPF 13.0 SEER /11.0EER Yes n/a Yes 243 cfm No No Programmable Switch No Setback Required Auto n/a R-4.2 ITEM OR SYSTEM TAG(S) Number of Systems MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity xl.432 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance3 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference ot plans and specifications per footnote t. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sqft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF-1 for performance method duct sealing requirements. 144 (a &b) 144 (a &b) 144 (a &b) 144 (a &b) 144(c) 144(c) 144(c) 144(d) 144(e) 144(f) 144 (f) 144 (k) 56,61 4 btuh 45,41 1 btuh 60,326 btuh 54,252 btuh Constant Volume Yes No No Economizer Constant Temp Constant Temp No 47,303 btuh 45,802 btuh 56 ,8 18 btuh 55,874 btuh Constant Volume Yes No No Economizer Constant Temp Constant Temp No NOTES TO FIELD - For Buildina Deoartment Use Onlv EnergyPro 4.4 by EnergySoft User Number: 1712 Job Number: NR12-89 Page: 5 of 13 [WATER SIDE SYSTEM REQUIREMENT?Part 2 of 2 MECH-2-CJ PROJECT NAME White Construction Office DATE 12/9/2009 ITEM OR SYSTEM TAG(S) Number of Systems 2 WATER SIDE SYSTEMS: Chillers, Towers, Boilers, Hydronic Loops T-24Section Reference on Plans or Specification1 112(a) 123 MANDATORY MEASURES Equipment Efficiency Pipe Insulation PRESCRIPTIVE MEASURES Calculated Capacity Proposed Capacity Tower Fan Controls Tower Flow Controls Variable Flow System Design Chiller and Boiler Isolation CHW and HHW Reset Controls WLHP Isolation Valves VSD on CHW, CW & WLHP Pumps > 5 HP DP Sensor Location 1: For each chiller, cooling tower, boiler, and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Water side systems include wet side system using other liquids such as glycol or brine. 144 (a & b) 144 (a &b) 144 (h) 144 (h) 144 G) 144(j) 144Q) 144(j) 144 (j) 144(i) Service Hot Water, Pool Heating DHW Heater 1 Reference on Plans or Specification1 ITEM OR SYSTEM TAG(S) Number of Systems MANDATORY MEASURES Water Heater Certification Water Heater Efficiency Service Water Heating Installation Pool and Spa Efficiency and Control Pool and Spa Installation Pool Heater - No Pilot Light Spa Heater - No Pilot Light 1: For each water heater, pool heat and domestic water loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" ins the column. 113 (a) 113(b) 113(c) 114 (a) 114(b) 115(c) 115(d) Eemax EX3012 0% n/a n/a n/a n/a NOTES TO FIELD - For Buildina Derailment Use Onlv EnergyPro 4.4 by EnergySoft User Number: 1712 Job Number: NR12-89 Page:6of 13 MECHANICAL VENTILATION MECH-3-C PROJECT NAME White Construction Office DATE 12/9/2009 MECHANICAL VENTILATION (Section 121<b)2) A ZONE/SYSTEM Office Conference Break Room HVAC SHP-1 5 ton 1st Floor Office HVAC HP-2 5 ton 2nd Floor c E H I J K L M N AREA BASIS B 111o 1,396 155 78 C 1 oo 0.15 0.50 0.50 1,619 0.15 i D oo *< 5" Ss| 209 78 39 243 OCCUPANCY BASIS E Number ofPeople14.0 10.4 5.2 16.2 F « TJ O3 8 aO ~* 53 15.0 7.5 7.5 15.0 G £*"O 3x g 0 209 78 39 Total 243 Total H REQ'D V.AMax of(D or G)209 78 39 326 243 243 I ® 209 78 39 326 243 243 PRESCRIPTIVE REHEAT LIMITATION (Section 144(d)) VAV MINIMUM J 30% of DesignZone SupplyCFMK o fap L Max ofColumns H, J,K or 300 CFMM Design Min. AirSetpointN Transfer AirMinimum ventilation rate per Section 121 . Table 121-A Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load for egress purposes for spaces without fixed seating. Required Ventilation Air (REQ'D VA) is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS (column D or G). Must be greater than or equal to H, or use Transfer Air (column N) to make up the difference. Design fan supply cfm (Fan CFM) x 30%; or Condition area (ft. sq.) x 04 cfm/ft. sq.; or Maxinum of Columns H. J, K, or 300 cfm This must be less than or equal to Column L and greater that or equal to the sum of Columns H + N . Transfer air must be provided where the Required Ventilation Air (column 1) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (column 1) and the Design Minimum Air (column M), column H - M. EnergyPro 4.4 by EnergySoft User Number: 1 71 2 Job Number: NR1 2-89 Page:7of13 MECHANICAL SIZING AND FAN POWER MECH-4-C PROJECT NAME White Construction Office SYSTEM NAME HVAC SHP-1 5 ton 1st Floor DATE 12/9/2009 FLOOR AREA 1,629 IFAN POWER CONSUMPTION A FAN DESCRIPTION Supply Fan B DESIGN BRAKE HP 0.750 C D EFFICIENCY MOTOR 77.0% DRIVE 100.0% E NUMBER OF FANS 1.0 | F PEAK WATTS B X E X 746 / (C X D) 727 Total Adjustments FILTER PRESSURE ADJUSTMENT EQUATION144 A A) If filter pressure drop is greater than 1 inch W.C. enter filter pressure drop. SPa on line 4 and Total Fan pressure SPf on Line 5. B) Calculate Fan Adjustment and enter on Line 6. C) Calculate Adjusted Fan Power Index and enter on Line 7. 1) TOTAL FAN SYSTEM POWER (Watts, Sum Column F) 2) SUPPLY DESIGN AIRFLOW (CFM) 3) TOTAL FAN SYSTEM POWER INDEX (Row 1/Row 2) 4) SPa 5) SPf 6) Fan Adjustment = 1-(SPa - 1)/SPf 7) ADJUSTED FAN POWER INDEX (Line 3 x Line 6) 727 2,000 0.363 ITEM or SYSTEM TAG(S) PRESCRIPTIVE MEASURES Electric Resistance Heating 1 Heat Rejection System 2 Air Cooled Chiller Limitation T-24 Section 144(g) 144(h) 144(i) Capacity Exception Notes 1. Total instated capacity (MBtu/hr) of alt electric heal on this project exclusive of electric auxiliary heat for heat pumps. If electric heat is used, explain which exception(s) to Sectton(g) apply. 2. Are centrifugal fan cooing towers used on this project? (Enter "Yes" or "No") If centrifugal fan cooling tower are used, explain which exception(s) to Section 144(h) apply. 3. Total instated capacity (tons) of all water and air cooled chillers under this permit. If there are more than 100 tons of air-cooled chiier capacity being hstalled, explain vtflicn exception(s) to Section 144(1) apply. EnergyPro 4.4 by EnergySoft User Number: 1712 Job Number: NR12-89 Page: 8 of 13 MECHANICAL SIZING AND FAN POWER MECH-4-C PROJECT NAME White Construction Office SYSTEM NAME HVAC HP-2 5 ton 2nd Floor DATE 12/9/2009 FLOOR AREA 1,619 IFAN POWER CONSUMPTION A FAN DESCRIPTION Supply Fan 8 DESIGN BRAKE HP 0.750 c D EFFICIENCY MOTOR 77.0% DRIVE 100.0% E NUMBER OF FANS 1.0 F PEAK WATTS B X E X 746 / (C X D) 727 Total Adjustments FILTER PRESSURE ADJUSTMENT EQUATION144-A A) If filter pressure drop is greater than 1 inch W.C. enter filter pressure drop. SPa on line 4 and Total Fan pressure SPf on Line 5. B) Calculate Fan Adjustment and enter on Line 6. C) Calculate Adjusted Fan Power Index and enter on Line 7. 1) TOTAL FAN SYSTEM POWER (Watts, Sum Column F) 2) SUPPLY DESIGN AIRFLOW (CFM) 3) TOTAL FAN SYSTEM POWER INDEX (Row 1/Row 2) 4) SPa 5) SPf 6) Fan Adjustment = 1-(SPa - 1)/SPf 7) ADJUSTED FAN POWER INDEX (Line 3 x Line 6) 727 2,000 0.363 1. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 W/cfm tor Constant Volume systems or 1.25 W/cfm tor VAV systems. ITEM or SYSTEM TAG(S) PRESCRIPTIVE MEASURES Electric Resistance Heating ' Heat Rejection System 2 Air Cooled Chiller Limitation T-24 Section 144(g) 144(h) 144(i) Capacity Exception Notes 1. Total instated capacity (MBtu/hr) of aB electric heat on this project exclusive of electric auxiliary heat for heat pumps. If electric heat is used, explain which exception(s) to Section(g) apply. 2. Are centrifugal fan cooing towers used on this project? (Enter "Yes" or "No") rf centrifugal fan cooling tower are used, explain which exceptions) to Section 144(h) apply. 3. Total instated capacity (tons) of all water and air cooled chillers under this permit. If there are more than 100 tons of air-cooled chiller capacity being retailed, explain which exception^) to Section 144(i) apply. EnergyPro 4.4 by EnergySoft User Number: 1712 Job Number: NR12-89 Page: 9 of 13 [MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM PROJECT NAME White Construction Office DATE 12/9/2009 DESCRIPTION Equipment and Systems Efficiencies X 911 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. | | §)15(a) Fan type central furnaces shall not have a pilot light. [X] §1 23 Piping, except that conveying fluids at temperatures between 60 and 1 05 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. [X] §1 24 Air handling duct systems shall be installed and insulated in compliance with Sections 601 , 602, 603, 604, and 605 of the 2001 CMC Standards. Controls §1 22(e) Each space conditioning system shall be installed with one of the following: [X~| §1 22(e)1 A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off-hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or | §| 22(e)1 B An occupancy sensor to control the operating period of the system; or j §l22(e)1C A 4-hour timer that can be manually operated to control the operating period of the system. |X| §1 22(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. j | §!22(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. [X~| §)22(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. |X_ §1 22(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. XJ §1 12(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. Designer Enforcement EnergyPro 4.4 by EnergySoft User Number: 1712 Job Number: NR12-89 Page:10of13 [MECHANICAL MANDATORY MEASURJS"Part 2 of 2 MECH-MM PROJECT NAME White Construction Office DATE 12/9/2009 Description Ventilation | X | §1 21 (e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. | | §| 22(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. | j §| 22(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. j j §!21(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or [X~| §l21(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or §1 21 (f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display dtvice; or | j §] 21 (f)4 Another method approved by the Commission. Service Water Heating Systems | | §t I3(b)2 I' a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. j j §1 13(c) Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 1 10 degrees F. ' Designer Enforcement EnergyPro 4.4 by EnergySoft User Number: 1712 Job Number: NR12-89 Page:11of13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME White Construction Office DATE 12/9/2009 SYSTEM NAME HVAC SHP-1 5 ton 1st Floor FLOOR AREA 1.629 ENGINEERING CHECKS SYSTEM LOAD Number of Systems Heating System Output per System Total Output (Btuh) Output (Btuh/sqft) 58,000 58,000 35.6 Cooling System Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sqft) Total Output (sqft/Ton) 58,500 58,500 4.9 35.9 334.2 Air System CFM per System Airflow (cfm) Airflow (cfm/sqft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sqft) 2,000 2,000 1.23 410.3 16.3 0.20 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM 1,814 326 Sensible 42,862 2,143 2,707 2,143 49,856 Latent 5,839 CFM 1,622 5,169 326 11,008 Sensible 24,998 1,250 12,093 1,250 39,590 Note: values above given at ARI conditions HVAC EQUIPMENT SELECTION YORK THGD60S Total Adjusted System Output (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK 54,252 54,252 2,647 2,647 Sep 4pm HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 35.0 °F 63.8 °F Outside Air 326dm 69.4 °F / / V 84.9 °F Supply Air Ducts*j, Supply Fan 2000 cfm Heating Coil Return Air 84.3 °F 70.0 °F I POOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 82.7 / 67.7 °F >—.ff~ Outside Air 326 cfm 75.0 / 60.3 F 76.2/61.5°F 76.2/61.3°F • 51.1/49.8°F > >' i l t Supply Air Ducts Supply Fan 2000 cfm Cooling Coil 52.1/50.2°F 43.6% R.H. ft Return Air Ducts EnergyPro 4.4 by EnergySott User Number: 1712 Job Number: NR12-89 Page: 12 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME White Construction Office DATE 12/9/2009 SYSTEM NAME HVAC HP-2 5 ton 2nd Floor FLOOR AREA 1.619 iNGINEERING CHECKS SYSTEM LOAD Number of Systems Heating System Output per System Total Output (Btuh) Output (Btuh/sqft) 58,500 58,500 36.1 Cooling System Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sqft) Total Output (sqft/Ton) 58,500 58,500 4.9 36.1 332.1 Air System CFM per System Airflow (cfm) Airflow (cfm/sqft) Airflow (cfm Ton) Outside Air (%) Outside Air (cfm/sqft) 2,000 2,000 1.24 410.3 12.1 0.15 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK CFM 1,642 243 Sensible 40,843 2,042 2,030 2,042 46.957 Latent 3,238 COIL HTG. PEAK CFM 1,264 4,582 243 7,820 Sensible 21,863 1,093 9,030 1,093 33,079 Note: values above given at ARI conditions HVAC EQUIPMENT SELECTION YORK B2HZ060 Total Adjusted System Output (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK 55,874 55,874 Jul 4pm 45,802 45,802 Jan 12am HEATING SYSTEM PSYCH ROM ETRICS (Airstream Temperatures at Time of Heating Peak) 65.3 °F 65.3 °F 86.5 °F Outside Air 243 cfm 69.5 °F ^ * ; / r f < (®/ Supply Fan Heating Coil 2000 cfm f Supply Air Ducts*', Return Air Ducts 86.0 °F 70.0 °F I POOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 82.7 / 67.7 °F 75.9/60.3°F 75.9/60.1°F 50.0 / 48.6 °F * *Outside Air 243 cfm j i 74.9 / 59.3 °F + tf— (®fr^*— ^ Supply Fan Cooling Coil V 2000 cfm .-*> »V\ Supply Air Ducts 40.2% R.H. Return Air Ducts EnergyPro 4.4 by EnergySoft User Number: 1712 Job Number: NRt2-89 Page:13of13 SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# HV# BP DATE I I The following qViestionJ represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT - HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. 5. Organic Peroxides 9. 6. Oxidizers 10. 7. Pyrophorics 8. Unstable Reactives 12. 1. Explosive or Blasting Agents 2. Compressed Gases 3. Flammable/Combustible Liquids 4. Flammable Solids Water Reactives Cryogenics Highly Toxic or Toxic Materials Radioactives 13. Corrosives 14. Other Health Hazards 15. None of These. PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HMD): If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 1255 Imperial Avenue, 3 floor, San Diego, CA 92101. Call (619) 338-2222 prior to the issuance of a building permit. FEES ARE YES 1. D 2. D 3. D 4. D 5. D 6. D REQUIRED. Expected Date of Occupancy: / / NO JZf Is your business listed on the reverse side of this form? (check all that apply). jy Will your business dispose of Hazardous Substances or Medical Waste in any amount? J7f Will your business store or handle Hazardous Substances in quantities equal to or greater than ^^55 gallons, 500 pounds, 200 cubic feet, or carcinogens/reproductive toxins in any quantity? JS Will your business use an existing or install an underground storage tank? _^^.Will your business store or handle Regulated Substances (CalARP)? •^j Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? D CalARP Exempt Date Initials D CalARP Required Date Initials D CalARP Complete Date Initials PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer to any of the questions below is yes, applicant must contact the Air Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the issuance of a building or demolition permit. Note: if the answer to questions 3 or 4 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days prior to commencing demolition or renovation, except demolition or renovation of residential structures of four units or less. Contact the APCD for more information. I. YES D D D D NQx £] Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD factsheet at httD://www.sdaDcd.ora/info/facts/permits.pdf. and the list of typical equipment requiring an APCD permit on the reverse side of this from. Contact APCD if you have any questions). D (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? (Public and private schools may be found after search of the California School Directory at http://www.cde.ca.aov/re/soV: or contact the s appropriate school district). ,^^Will there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-friable asbestos? Q Will there be demolition involving the removal of a load supporting structural member? Briefly describe business activities: (Wlvodoi- £IWUKX£ Briefly describe proposed project: O^eg. best of my knowledge and belief the responses made herein are true and correct. Name of owner or Authorized Agen Signature of Owner or Authorized Agent I5 Date FOR OFFICIAL USE ONLY:FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:, BY:DATE:/ / EXEMPT OR NO FURTHER INFORMATION REQUIRED COUNTY-HMD APCD RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY COUNTY-HMD APCD RELEASED FOR OCCUPANCY COUNTY-HMD APCD HM-9171 (04/07)County of San Diego - DEH - Hazardous Materials Division Check a License or Home Improvement Salesperson (HIS) Registration - Contractors Stat... Page 1 of 1 Department of Consumer Affairs *••* ^ Contractors State License feoard Contractor's License Detail - License # 452513 on DISCLAIMER: A license status check provides Information taken from the CSLB license database. Before relying on this information, you should be aware of the following limitations. • CSLB complaint disclosure is restricted by law (B&P 7124.6). If this entity is subject to public complaint disclosure, a link for complaint disclosure will appear below. Click on the link or button to obtain complaint and/or legal action information. • Per B.&P 707117, only construction related civil judgments reported to the CSLB are disclosed. • Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration. • Due to workload, there may be relevant information that has not yet been entered onto the Board's license database. License Number: Business Information: Entity: Issue Date: Expire Date: License Status: Additional Status: Classifications: Bonding: Workers' Compensation: 452513 Extract Date: 02/02/2010 S P WHITE CONSTRUCTION INC 5937 DARWIN COURT #100 CARLSBAD, CA 92008 Business Phone Number: (760) 931-1130 Corporation 02/24/1984 02/29/2012 This license is current and active. All information below should be reviewed. The license may be suspended on 02/03/2010 if the workers' compensation insurance policy is not filed with the CSLB. CLASS DESCRIPTION B GENERAL .BUILDING CQNIRACTOR CONTRACTOR'S BOND This license filed Contractor's Bond number 22227030 in the amount of $12,500 with the bonding company WESTERN. SURETYCOMPANY. Effective Date: 01/01/2007 Contractor's Bonding History BOND OF QUALIFYING INDIVIDUAL 1. The Responsible Managing Officer (RMO) STEPHEN PERRY WHITE certified that he/she owns 10 percent or more of the voting stock/equity of the corporation. A bond of qualifying individual is not required. Effective Date: 02/24/1984 This license has workers compensation insurance with the EVEREST NAUQNAL INSyRANCE COMPANY Policy Number: 7600000885091 Effective Date: 01/01/2009 Expire Date: 01/01/2010 Workers' Compensation History Personnel List Conditions of Use | Privacy Policy Copyright ©2010 State of California https://www2.cslb.ca.gov/OnlineServices/CheckLicense/LicenseDetail.asp 02/02/2010 CB092130 2540 GATEWAY RD WHITE: 3434SF SHEL.L TO OFFICE Approved Date Building Planning Engineering Fire APCD Health Forms/Fees Rec'd Due? Encina HazHealthAPCD PFF Comments Building Planning Engineering Fire / /13/tO /2-// f/6 4~ /l/s'/iri 2-/0 Need? Application Complete? v N Fees Complete? v N By: By: