HomeMy WebLinkAbout2540 LA COSTA AVE; ; 77-8998; Permit(
MODEL NP·--~-------
,. . BUILDING PERMIT APPLICATION
City of CARLSBAD, CALIFORNIA 92008
Applicant to complete numbered spaces only. Phone 7 29-1181 Perm1I No.
JOB A.DOR ES$ ASSESSOR 'S
PARCEL NUMBER
1 LEGAL I DESCA LOT NO Pf/ I 8LK I TRACT t, I (1. f-il,f# evvK PAGE PAR,
-,.,/ tOStt ATTACH[O 5HUTI
, _, PHONE
. :.~7-"~ sll, ___ ;
"p
:~;' ,...c r-· ~~STATE LIC. NO. C ITY LIC, NO,
'tZ--;;11 ~ •/j --~..:
PHON E LICENSE NO.
'• I 71:
[NCINCCR MAIL. ADDR ESS . Pl-40Nt LICENSE NO.
5
COMPENSATION INS. CAR RIER M A IL AOORCSS 911lA.NCH
6 ; . -1S
USE 0 ,. IUILCIN.iG
1 I NO. BDRMS 3 ~
NO. BATHS r,.2 /'<._
8 Class lfl work : DlNEW tJ ADDITION 0 ALTERATION 0 REPAIR 0 MOVE 0 REMOVE
9 Describe work:
10 Change of use from /
Change of use to
i '
11 Valuation of work: $ ,~,~ I PLAN CHECK FEE$ < PERMIT FEE$ 23/, -
1-S_P_E_C_I_A_L_C_O_N_D_I_T_I O_N_S_: ------------------~ Type of
Const
1-----------------------------~ s ,ze of Bldg. (Total) Sq. Ft. 21.b
1----------------------.-----------Fire
D
AP:A1E ~,q ·:~;;:: nv ~:~:! ... l. J/H! r~, u ibwe11,ng Units
APPLICATION ACCEPTED av
DATE
PLANS CHECKED BY
MICRO FILM1FEE Occupancy 3/k, Group ,
No. of 2-II/lax.
Stories 0cc. Load
Use I Fire Sprinklers
Zone I Required 0Yes
OFFSTREET PA RK ING SPACES
No. J Covered -::• Sq. Ft. / !No,
Open
0No
NOTICE ' Special Approvals Required Received Not Required
SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMB
ING, HEATING. VENTILATING OR AIR CONDI TIONING.
THIS PERMIT BECOMES NULL AND VOI D IF WORK OR CONSTRUC·
TION AUTHORIZED IS NOT COMME NCED WITHIN 120 DAYS.OR IF
CONSTRUCTION O R WORK IS SUSPENDED OR ABANDONED FOR A
PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COM·
MENCED.
PLANNING DEPT,
HEALTH DEPT.
FIRE DEPT
SOIL REPORT ...
OTHER (Specify)
~/;4pff..f fJfi1ocJ~~bYK~::::TT~/tIJE Rllf E ~~~if~~~ 1tJR R 1~~~ ...._E_N_G_IN_E_ER_I_N_G_D..cE_Pr_.-+----------1----------1---------1
ALL PROVISION S OF LAWS ANO ORDINANCES GOVERNING THIS WATER DEPT. TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED l---------+----------1----------1---------1
HEREIN OR N OT, THE GRANTING OF A P.ERMIT DOES NOT PRESUME ,0 GIVE AUTHORITY TO V IOLA TE OR CAN CEL THE PROVISIO NS OF A N Y OTHER STAT E OR LO<:;A L LAW REGULATING
CONST RUCTION OR J HE PERFORMANCll' O F CONSTRUCTION.
(DAT[ I
.SIGNATUNE 0 ,-OWNE,-(IF OWNCIII •UILOtllll DATE)
WHEN PROPERLY VALIDATED (IN THIS SPACE) THIS IS YOUR PERMIT
PLAN CHECK VALIDATION CK. M.O. CASH PERM IT VALIDATION CK. M.O. CASH
T OTAL FEES $ __ ~---'----
INSPECTOR
INSPECTION RECORD
-...----
DATE REMARKS •.• SPEC• R
FOUNDATIONS;
SET BACK
TRENCH
REINFORCING
FOUNDATION WALL &
WEATHER PROOFING
CONCRETE SI
FRAMING
INT. LATHINC
EXT. LATHIN
MASONRY
FINAL
USE SPACE BE
REuuEST FOR INSPECTION TIME: 1:<fS--
(~ • PERMIT NO. L-:J---?>o -11 INSPECTOR DATE:
OWNER on~·
ADDRESS If' ~5 _D La, C~h ... uN-C ·
BUILDING
0 FOUNDATION
0 REINFORCING STEEL
0 MASONRY
0 GROUT -GUNITE I
0 FLOOR AND CEILING FR,n~ o/
D SHEATHING V . ~ ~
0 FRAME
0 EXTERIOR LATH \ -
0 INSULATION \.
DRYWALL
PLUMBING
0 UNDERGROUND PLUMBING
0 UNDERGROUND WATER
0 ROUGH PLUMBING
0 TOP OUT PLUMBING
0 SEWER AND PL/CO
0 TUB OR SHOWER PAN
0 GAS TEST
□\Ill.A--~
ELECTRICAL
0 TEMPORARY SERVICE
0 ELECTRIC UNDERGROUND
0 ROUGH ELECTRIC
0 POOL BONDING
0 ELECTRIC SERVICE
0 CEILING HEAT
0 G.F.1. <:E?~~::CTOR
MISCELLANEOUS
D PLENUM AND DUCTS
0 COMBUSTION AIR
0 PATIO
0 SIGN
0 GRADING
0 DRIVEWAY
0 CONDITIONED AIR SYSTEMS
0 REFER PIPING
FINAL
READY FOR INSPECTION: D MONDAY
~ □TUESDAY □WEDNESDAY~ FRIDAY
~j,M
, D P.M.
SPECIAL INSTRUCTIONS t\,')'\oJ 't<....Q_c4\
REQUESTED BY ___ D=--\ .......... '0::;;...._ ____________ PHONE NO.
PERSON TAKING REPORT _______ _
-
PLUMBING PERMIT APPLICATION
City of CARLSBAD, CALIFORNIA 92008 f
Applicant to complete numbered spaces only Phone 729-1181 Permit No
JOB AOl'>lll £$5
~Sd'/ 14 I',:.:..~~✓+ l.fJ/e-
LOT NO,
1 •••
TlltACT /
LtOAL I I/, ln<:./-e:t.., 1 0£SC"• ') 7' I
OWNC,-
be.tJ.a) -----L -,;--t-
MAIL ADDfltESf'°" ti. PHONE
2 lh,Jo l/. / l h,,1 oJ sr 714. -53(.-~17 Jiu,: ,., 1•, i:1t &.:~~cli '1-t.
co_:.1,: ... c'T~ . .._L; U
-tA.f,
f 'tlL ADD"ESS ·!lit• PHONC
STATE LIC,<)l"O. CITY LIC, NO.
3 r , . / . ,, r~-:n· lstJ't CoJt ¼·tit,,, 7~7'-/i/t ,;;,,, / ./ ,. .IS//-;· 1 • I 1 '.i I./ ll ~ / ;, ,
A,-CHITCCT Ofll 0/SfGNCft d NIA.IL .Coofllf15S PHONE LICENSE NO.
4
CNGIN£EA MAIL AO0flt£55 PHONE LICENSE NO.
5
COMPENSATION (NS, CARRIER MAIL AODJltE55 BtlllANCH
6 i,·...-~ I (. IJ./7Jc-i?./I /A
Ul,C-Of' 9UILDTNG ~
7
8 Class of work: r NEW 0 ADDITION 0 ALTERATION 0 REPAIR
9 Describe work: PL1/ m l:,/4LA . I
PERMIT FEES
No. Type of Fixture or Item Fee
SPECIAL CONDITIONS WATER CLOSET (TOILET) $
;,-BATHTUB .,,.,, LAVATORY (WASH BASIN)
SHOWER I ) (...
I KITCHEN SINK & DISP ( ,:'I)
DISHWASHER
APPLICATION ACCEPTED BY PLANS C><EC~ED BY APPROVED FDR ISSUANCE BY LAUNDRY TRAY .
CLOTHES WASHER
CATE ./ WATER HEATER
NOTICE ~ URINAL
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC-DRINKING FOUNTAIN
TION AUTHORIZED IS NOT COMMENCED WITHIN 120 DAYS,OR IF FLOOR-SINK OR DRAIN CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A
PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COM· SLOP SINK -MENCED. I GAS SYSTEMS. NO.OUTLETS ... /!<_,C, I HEREBY CERTIFY THAT I HAVE READ ANO EXAMINED THIS
APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. WATER PIPING & TREATING EQUIP.
ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED WASTE INTERCEPTOR
HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT
PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE VACUUM BREAKERS PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING
CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. LAWN SPRINKLER SYSTEM
SEWER NUMBER CLEANOUTS
CESSPOOL
SEPTIC TANK C. PIT ..
ROOF DRAINS
SIGNATURE. o, CONTIU.CTOIIII OJI AuTHOflltE.0 AGtNT (DATE) I< ' ~ . ,• ..
ISSUANCE FEE $ .., ~
SIGNATll,.E. or OWH[.11 IP' OWN[II: 8Ull.OEfl (OAT() TOTAL FEES $ _,-,,
WHEN PROPERLY VALIDATED (IN THIS SPACEI THIS IS YOUR PERMIT
PLAN CHECK VALIDATION CK. M.O. CASH PERMIT VALIDATION CK . M.O. CASH
INSPECTOR
ELECTRICAL PERMIT APPLICATION
City of CARLSBAD, CALIFORNIA 92008
Applicant to complete numbered spaces only Phone 729-1181 Permit No
JOB ADDRESS
LOT NO. ·'f' I 8LK. I TRACT (QSEE ATTACHED SHEET) LEGAL I 1 DESCR.
OWNER MAIL ADDRESS ZIP PHONE
2 ---c....~¥• 71-!I Darla ~ -.. -
CONTRACTOR MAIL ADDRESS ~:::., PHONE STATE LIC. NO. C ITV LIC. NO.
3 tzt.e 852 • ~ -
ARCHITECT OR DESIGNER MAIL ADDRESS PHONE LICENSE NO.
4
ENGINEER MAIL ADDRESS PHONE LICENSE NO.
5
COMPENSATION INS CARRI ER MAIL ADDRESS BRANCH
6 -,cm ft1e -
USE OF BUILDING
7
8 Class of work: □NEW 0 ADDITION 0 ALTERATION 0 REPAIR
9 Describe work: 1ect1:lcal v1rlDg
PERMIT FEES
No. Each Fee
SPECIAL CONDITIONS: SWIMMING POOL WIRING,
NO INCREASE IN SERVICE
NEW CONSTRUCTION, FOR EACH
APPLICATION ACCEPTED BY PLANS CHECKED BY APPROVED FOR ISSUANCE BY AMPERES OF MAIN SERVICE, SWITCH , 2· ~ o: FUSE OR BREAKER ..
DATE NEW SERVICE ON EXISTING BLDG.
FOR EA. AMPERE OF INCREASE NOTICE IN MAIN SERVICE, SWITCH, FUSE
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC-OR BREAKER
TION AUTHORIZED IS NOT COMMENCED WITHIN 120 DAYS,OR IF
CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A REMODEL, ALTERATION, NO CHANGE PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COM
MENCED. IN SERVICE, FOR EA. AMPERE OF
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS INCREASE
APPLICATION AND KNOW THE SAME TO BE TRUE ANO CORRECT. ALL PROVISIONS OF LAWS ANO ORDINANCE!> GOVERNING THIS
TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED
HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT TEMP. SERVICE UP TO AND INCLUD· PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE
PROVISIONS OF ANV OTHER STATE OR LOCAL LAW REGULATING ING 200 AMP.
CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION.
I -~✓/ TEMP. SERVICE OVER 200 AMP. ,.,. / PER 100 , ~ ,.
SIGNATURE OF CONTRACTOR OR AUTHORIZED AGENT (DATE) ISSUANCE FEE ,; ! Q;11
TOTAL FEES ~
e.•"'N.6..TURE OF' nwNER IF OWNER BUfLOER Hl4T~\
WHEN PROPERLY VALIDATED (IN THIS SPACE) THIS IS YOUR PERMIT
PLAN CHECK VALIDATION CK. M .O. CASH PERMIT VALIDATION CK. M.O. CASH
INSPECTOR
MECHANICAL PERMIT APPLICATION 1 13•*~
City of CARLSBAD, CALIFORNIA 92008
A /' I t b d , Phone 729-1181 pp ,cant to comp e e num ere spaces on y. _ .. erm1 o. ' p "t N
JOB ADDIII tSS
-j f r~rA::'" ilv 0:~
LOT NO.
1 m
TRACT ,□srt ATTACHt.0 5HC£TI LCGAL I 1 ouc•.
OWNCIII M,',IL AO011U5S ZIP c•~e,o PHONC
2 ' »~l/ 7~, . 1' J 11;/Jr; 1JJ/-C'•1I,. 3 I ' WAil q'UJD8 ; , ,
CONT'U,CTOft MAIL ADOPIESS , PHONE STATE LIC. NO. CITY LIC. NO.
3 J./~.J-1.1.,·,,. -· /, JC fl1eiA-lt !. r r..t;JU»~ ~ I -' , .''I I !," I ., './ -' AIIICHITCCT Otll OESIGNE!lt . 1 .. MAIL ADDRESS PHON [ LICENSE NO,
4 ' tNGINtEIII MAIL. AODIII tSS 'Ill\ PH0N£ LICENSE NO,
5 IL:1;, "( ,i_ ... , A' "'T/ "'" , --. J .. . .f
LENOEIII MAIL A001111£SS 8111ANCH
6 "' \ \ 't-{If • I
\_ .
US£ 0,. BUILDING ~· 1 7 -
8 Class of work: GNEW 0 ADDITION 0 ALTERATION 0 REPAIR
'\.-\ .l-;j! ~-.9 Describe work:
--c'
.ii' \
\ ,. .,
' Type of Fuel D Nat. Gas CY' LPG. D -,
Oil
PERMIT FEES
SPECIAL CONDITIONS. No. Type of Equipment Fee
J· -Air Cond. Units-H.P. Ea. $
f' ~ Refrigeration Units-H.P Ea.
-,_ Boilers HP. Ea.
-· . ' Gas Fired AC. Units Tonnage Ea. -) Forced Air Systems-B.T.U. / .'.:) s;;-M Ea. .:, --APPLICATION ACCEPTEO BV PtANS CHECKED av APPROVED FOR ISSUANCE BV Gravity Systems-8 .T.U. M Ea.
Floor Furnaces B.T.U. M
Wall Heateri. B.T.U. M
NOTICE Unit He&ters-B.T .U. M
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC• Evaporative Coolers
TION AUTHORIZED IS NOT COMMENCED WITHIN 120OAYS,OR IF, .,. Clothes Dryers ~ ..
CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A .
PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COM-Ventilation Fan
MENCED. Range Hood I HEREBY CERTIFY THAT I HAVE READ ANO EXAMINED THIS APPLICATION ANO KNOW THE SAME TO BE TRUE ANO CORRECT. Air Handling Unit-..,.. C.F.M. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED Incinerator HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION.
,~ \ L.,.. 1.1 ,,t-1,t
SIGNATUfltE 0,. CONT,-ACTO" OPt AVTHOlll1%CO AGENT i\(DATI:)
ISSUANCE FEE $ ~ .-·
TOTAL FEES $ ,;,,:. --r--AfCNATUlllt. OP' OWN[.,-I~ OWN[ft aulLD[lil') (DATl.l
WHEN PROPERLY VALIDATED UN THIS SPACE) THIS IS YOUR PERMIT
PLAN CHECK VALIDATION CK. M.O. CASH PERMIT VALIDATION CK. M.O. CASH
INSPECTOR
/
) f)e, ?7 -S<rj
RECEIVED . .. ~INffiDEPARTMENTAL INFORMATION SHEET
.BUILDING DEPARTMENT •
BUILDING ADDRESS:
DA TE : ______ $,..,E.._P ...... 1.....,91<-t .... 977'1..J. L_..
1-a as:ft; fl.uR.,' OFl'Y Oli CARLSBAD
Building Department
-~l=======================================================
'
PLANNING DEPARTMENT
ZONE _____ .... e_-_( __ LOT SIZE ___ __,_e/b,'-'-',..c: __ ·_· _LOT WIDTH. ________ _
•UNITS ALLOWED UNITS PROVIDEti
PARKING SPAC·E_S_R_E_Q_U-IR_E_D______ P OVI_D_E_D=====~====:::z=========
% COVERAGE ALLOWED --------+-µ"<-~P,::::-ROVIDED _-1,C)_..,..,,c::......::A~>=.__ __ _
BUILDING HEIGHT ALLOWED PROV ED _________ _
FRONT SETBACK:
ALLOWED----µ-+--
PROVIDED{;;--··
INTRUSIONS ~
SIDE SETBACK: REAR SETBACK:
LANDSCAPE & IRRIGATION PLAN COMMENTS:
':,P~---------------------------------
ENVIRONMENTAL PROTECTION REQ: ~(?=--J,.,-~·..,...,.~_,1_,.F---------------t;,',.,v rtir-
ADDITIONAL COMMENTS:
0
• uJI! DEPARTMENT
SPRINKLING SYSTEM ___________ FIRE PROTECTION EQUIP. ______ _
[IRE ALARMS EXITS ______________ _
'IRE HYDRANTS LOCATION ________________ _
,DDITIONAL COMMENTS ___________________________ _
. TO ISSUE: _____ DATE _______ OK TO FINAL. ______ DATE ____ _
•
PHIL.I~ HENKING BENTON
P1t1t•IDIENT • CIVIL 11:NGINltUI
Mola Development Company
417 Main Street
BENTON ENGINEERING, INC.
APPLIED SOIL MECHANICS -FOUNDATIONS
6717 CONVOY COURT
SAN DIEGO. CALIFORNIA 92111
November 10, 1977
Huntington Beach, California 92648
Subject:
Gentlemen:
Project No. 77-10-13DF
Report on Compacted Filled Ground
Lot 28 of La Costa South Unit No.
Carlsbad, California
Tl!:LU'HONI! !714) 1565-1IUU5
This is to report the results of tests and observations made in order to inspect the com-
paction of filled ground placed on a portion of Lot 20 of La Costa South Unit No. 1 in
Carlsbad, California. The fill was placed on November 2 and 3, 1977.
The approximate area and depth of filled ground placed under our inspection in accordance
with the approved specifications are shown on the attached Drawing No. 1, entitled
"Location of Compacted Filled Ground." The grading plan used for the placement of filled
ground, dated August 31, 1977, was prepared by Emerald Engineering of Huntington Beach,
California.
The approximate locations at which the tests were taken ore shown on the attached Drawing
No. 1 and the final test results are presented on page 3 under the "Table of Test Results."
The laboratory determinations of the maximum dry densities and optimum moisture contents
of the major fill materials ore presented on page 3 under the "Laboratory Test Results." The
tests were taken on the dates indicated below:
Test Number
1, 2, and 3
4, 5, and 6
Date
November 2, 1977
November 3, 1977
The final results of tests and observations indicate that the compacted filled ground has been
placed at 90 percent of the maximum dry density or greater. It has been determined that
the fill materials, compacted to 90 percent of the maximum dry density, have a safe bearing
value of 1,510 pounds per square foot for one foot wide continuous footings founded at a
minimum depth and placed five feet or more inside the top of compacted filled ground slopes.
If footings are placed closer to the exposed slopes than 5 feet inside the top of compacted
filled ground slopes, these should be deepened one foot below a 1 1/2 horizontal to 1 vertical
)
Project No. 77-10-'13DF
Mola Construction Company
-2-November 10, 1977
line projected outward and downward from a point 5 feet horizontally inside the top of
compacted filled ground slopes.
Expansive soil conditions exist in the upper three feet below finished grade. Therefore, in
order to minimize possible detrimental effects caused by the potentially expansive soils, the
fol lowing special design and precautions are recommended:
1. Use continuous interconnected reinforced concrete footings, wherever possible, and
place these at a minimum depth of 2 feet below the lowest adjacent exterior final ground
surface. If isolated interior column footings are required, these should be placed at a depth
of 2 .5 feet below the lowest adjacent ground surface.
2. Reinforce and interconnect continuously with steel bars al I interior and exterior footings
with a minimum of one #5 bar at 3 inches above the bottom of all footings and one 15 bar ·
placed 1 1/2 inches below the top of the stems of the footings.
3. Reinforce all concrete slabs with a minimum of 6 x 6 -10/10 welded wire fabric
and provide a base layer of at least 4 inches of 3/4 to 1 inch size crushed rock beneath
al I concrete slabs. A moisture barrier should be provided above the crushed rock and then
2 inches of sand should be placed over the moisture barrier and below the bottom of the slab.
4. Separate garage slabs from perimeter footings by a 1/2 inch thickness of construction
felt or equivalent, to al low independent movement of garage slabs relative to perimeter footings.
Assure complete separation by extending the felt over the full depth of the front thickened
edge of the garage slab. Also, cut off the garage door stops at least 1/2 inch above the slab.
5. Provide positive drainage away from all perimeter footings with a vertical fall of at
least 5 inches in a horizontal distance of 5 feet outside the perimeter of the house.
6. Exercise every effort to assure that the soi I under the foundations and slabs has a
uniform moisture content 3 percent greater than optimum throughout the top 3 feet below
finished grade at the time of placing foundations and slabs.
Respectfully sul:rnitted,
BENTON ENGINEERING, INC.
By 4-tc!~~ C. Remer
Reviewed by_~___go:;:;:;:::::;~-~e::3~:~4 ~~~~;.---
S. H. Shu, Clvil Engineer
R.C.E. No. 19913
BENTON ENGINEEfllNG, INC,
D istr: (3) Addressee
( 1) City of Carlsbad
Building Department
•
---------·«-•,--•-·-----------Project No. 77-10-13DF
Mola Development Canpany
Depth
of Fill Field
Test at Test · Moisture
No. in Feet % dry wt
1 1.0 11.0
2 Natural 11.0
Ground
3 1.0 10.2
4 3.0 16.5
5 5.0 10.3
6 7.0* 11.5
*Indicates finished grade
-3-
TABLE OF TEST RESULTS
Maximum
Dry Dry
Density Density Percent
lb/cu ft lb/cu ft Can pact ion
92.6 116 .3 79 .6
1 I 4. l 115.2 99.0
105.5 116.3 90.7
107.8 116.3 92.6
108.3 116.3 93.2
106.0 116 .3 91.0
LABORATORY TEST RESULTS
November 10, 1977
Remarks
Rewori,ed
Ck on # l
The maximum dry densities and optimum moisture contents of the major fil I materials as
determined by the A.S.T.M. D 1557-70 method, that uses 25 blows of a 10 pound rammer
falling fran a height of 18 inches on each of 5 layers in a 4 inch diameter 1/30 cubic
foot canpaction cylinder, are presented as follows:
Soil Description
Light brown clayey fine sand
Light gray silty fine sand with slight
clay binder
BENTON ENGINEE111NG, INC.
Maximum
Dry Density
lb/cu ft
116.3
l 15. 2
Optimum Mois-
ture Content
% dry wt
12.9
13.7
____________ ,,,,,,, ..... _________ . .,_.,,,_, __ ,,.,, _____________ _ I LE.GEt-..10
[§B Indicates Approximate Locat,on of Compacted Filled Ground
--0-,nd,cates Approximate cut-F,11 Line
-,11-y,...,...,,,,.11 Indicates Approximate Top of Compacted Fi II Slope
Indicates Approximate Toe of Compacted FU I Slope
□ 0
/nd1cotes Approx,mote Vert1col Depth of Fill in Feet
Indicates Approximate Location of Field Otms,ty Test
~
F'~OPEl<'..TY LINE ._________ ...:::;.___:~.,__ ___ __,
DATE: 11-10·1~77.
PROJECT NO.
77-\0-t?>OF
LA COST~ AVE.NUE
Ol<:.AWN 1 K.L.Green
LOCATION OF COMPACTED FILLED GROUND
LA C0"5TA SOUTH Ut\!IT NO. 1
LOT ze
CARLSe>AD, CALIFORN\f:,,..,
BENTON ENGINEERING, INC.
\
I
4)
\
SCA.LE: \11 =20'
DRAWING NO.
1
i
I~
I
umber of cubic yards
Cut
otal
ompacted f i I Is
Proposed Schedule of
0 eratlons (dates)
R.C.E.
r no)
Start
Application for Grading Permit
CITY OF CARLSBAD
PERMIT NO. ___ _
(letter code+ number)
L= lot
PUBLIC WORKS & BUILDING DEPARTMENT
1200 Elm Avenue
729-1181
$=subdivision
C=City contract
Phone
Phone
Phone
Waste
Finish
Surety Bond Bond No.
Surety Company
Surety Address
Date Fi led Rec'd by
Cash deposit
$
Rec'd by Date f i I ed
The fol lowing documents are required and shal I
become a part of the grading permit when they
are approved.
__ Grading plans
__ Soi I port
__ D nage structures
ompaction report
__ Specifications
__ Vicinity map
__ Retaining wal Is
Other
SPECIAL CONDITIONS WHICH ARE MADE
A PART OF THIS PERMIT
Authorized hours of o eratlon: 7:00 AM to
5:00 PM, Monday-Friday.
2. Haul routes are to be a
Engineer.
3. Ade uate rovisions shal I be made for
direction
I hereby acknowledge that I have read the appl ica-1-----------------------
tion and state that the information I have provide INSPECTION DATE INSPECTOR'S
is correct and agree to comply with all City SIGNATURE
ordinances and State laws regulating excavating an Ground preparation
grading, and the provisions and conditions of any 1-----------------------permit issued pursuant to this application. Rough grading
. Compaction report rec'd.
Signature of Permittee_-,,+,'------,~'----+ Planting & drainage
Owner or authorized Final certification rec'd.
Grading permit fee$ Work completed
Surety bond released
Permit Validation
by _________________ Date _____ -1
Permit Expiration Date --------------TH IS FORM WHEN PROPERLY VALIDATED BY SIGNATURE IS A PERMIT TO DO THE WORK DESCRIBED
THIS PERMIT IS VALID FOR A SIX (6) MONTH PERIOD
,. /
1 4t, ~ trl': NOT.ICE OF
_/ J1. ('11 ~ ;t/' NONSIGNIFICANT
DECLARATION OF
ENVIRONMENTAL. IMPACT ~ If) 1e1
. .
NOTICE IS HEREBY GIVEN that the follo,,ing projects have sutmitted envirorurental
:inpact infornation to the City of carlsbad in accordance with the Environmental
Protection Ordinance of 1972 (Ord. 1150) and have been declared to have a non-
significant envirorurental impact. For further information, contact the Carlsbad
Planning Departrrent.
APPLICANT
Lester Turner, Jr.
Norman Kagen
Mola Development
CARI.SBl\D PLANNING DEPARI'MENT
LCX::ATION
La Costa So.
Unit No. 5
Lots 359, 360,
361
2600
Argonauta St.
La Costa
La Costa South
#1 Lot 28
ACTIVITY
Grading
Grading
Grading
-'
REASON FOR NEGATIVE
DFCTARATION
The activity is
in an urbanized
area and no
significant
vegetation exists
on the site.
The activity is
in an urbanized
area and no
significant
vegetation exists
on the site.
The activity is
iil an urbanized
area and no
significant
vegetation exists
on the site.