Loading...
HomeMy WebLinkAbout2544 CAMPBELL PL | 2548 CAMPBELL PL; ; PC060028; Permit08-16-2007 Job Address: Permit Type: Parcel No: Valuation: Reference #: Project Title: City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Permit No: PC060028 Building Inspection Request Line (760) 602-2725 2544/CAMPBELL PL CBAC PLANCK 2132610700 Lot#: $0.00 Construction Type: ARROWHEAD GEN INSURANCE-2 TI'S BLDG A=47504 SF SHELL TO OFFICE,BLDG 6=47,504 SF Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Applicant: PAULA STICKNEY 9696 WAYFARER LA MESA CA 91942 619743-2870 Owner: RED TEXAS REALTY L L C C/O ST. CROIX CAPITAL CORP 4350 EXECUTIVE DR #301 SAN DIEGO CA 92121 PENDING 05/12/2006 RMA Plan Check Fee Additional Fees $0.00 $0.00 Total Fees:$0.00 Total Payments To Date:$0.00 Balance Due:$0.00 Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE'similar to this, or as to which the statute of limitations has previously otherwise expired. 09-01-2006 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB061471 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: Applicant: STICKNEY 2548 CAMPBELL PL CBAD Tl Sub Type: 2132610700 Lot#: $1,662,640.00 Construction Type: Reference #: ARROWHEAD GEN INSURANCE BLDG-A,47,504 SF SHELL TO OFFICE COMM 0 VN PAULA 9696 WAYFARER LA MESA CA 91942 619-743-2870 Status: PENDING Applied: 05/11/2006 Entered By: KG Plan Approved: Issued: Inspect Area: Plan Check#: PC060028 Owner: RED TEXAS REALTY L L C C/O ST. CROIX CAPITAL CORP 4350 EXECUTIVE DR #301 SAN DIEGO CA 92121 Building Permit Add'l Building Permit Fee Plan Check Add'l -.Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee $4,417.44 $0.00 $2,871.34 $0.00 $0.00 $349.15 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Meter Size Add'l Reel. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF (31 05540) PFF (4305540) License Tax (31 041 93) License Tax (43041 93) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees HMP Fee TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $30,260.05 $0.00 $0.00 $0.00 $19,964.00 $0.00 $48.00 $1,589.50 $77.50 $0.00 $31,145.16 $0.00 $0.00 ?? $90,722.14 Total Fees:$90,722.14 Total Payments To Date:$0.00 Balance Due:$90,722.14 Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as lees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. 09-01-2006 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB061472 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: Applicant: STICKNEY PAULA 2544 CAMPBELL PL CBAD Tl Sub Type: 2132610700 Lot#: $1,662,640.00 Construction Type: Reference #: ARROWHEAD GEN INSURANCE BLDG-B,47,504 SF SHELL TO OFFICE COMM 0 VN 9696 WAYFARER LA MESA CA 91942 619-743-2870 Status: PENDING Applied: 05/11/2006 Entered By: KG Plan Approved: Issued: Inspect Area: Plan Check*: PC060028 Owner: RED TEXAS REALTY L L C C/O ST. CROIX CAPITAL CORP 74350 EXECUTIVE DR #301 SAN DIEGO CA 92121 Building Permit Add'! Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee $4,417.44 $0.00 $2,871.34 $0.00 $0.00 $349.15 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Meter Size Add'l Reel. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF (31 05540) PFF (4305540) License Tax (31 041 93) License Tax (43041 93) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees HMP Fee TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $30,260.05 $0.00 $0.00 $0.00 $19,964.00 : $0.00 $104.00 $1,090.00 $57.00 $0.00 $31,145.16 $0.00 $0.00 ?? $90,258.14 Total Fees:$90,258.14 Total Payments To Date:$0.00 Balance Due:$90,258.14 Inspector: FINAL APPROVAL Date: .Clearance: NOTICE: Please take NOTICE that approval of your project includes the Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. PERMIT ric*- /'yroi•qciuri . /06*f CITY OF CARLSBAD BUILDING DEPARTME •\635 Faraday Ave., Carlsbad, CA 92008 ***• 1. PROJECT, FOR OFFICE USE ONLY PLAN CHECK NO. EST. VAL. Plan Ck. Deposit Validated B Date Business Name (at this address) Subdivision Name/Number Unit No/ Phase No.Total # of units 8BOL "~Description of Work SQ. FT. 2. CONTACT PERSON (if different from applicant) , # of Bathrooms Name ,3. ', APPLICANT D Contractor £ Address Agent for Contractor;.-^Owner City [Agent for Owner '-743-2X70 Name 4. PROPERTY OWNER Address State/Zip Telephone # r Pfc . „ State/Zip Tefephone* II". ./CONTRACTOR -,COMPANY NAME ' ,,,.-. . . (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basts for the alleged exemption. Any violation of Section 7031.5 by any applicant for a fermit subjects the applicant tqa civil penalty of not more than five hundred dollars [$500]). Name State License # Address License Class City State/Zip City Business License # Telephone # Designer Name Address City State/Zip Telephone State License # 6. WORKERS'COMPENSATION , ,., ., .„„...„;,,,.-„ „ ., 'Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. l~l I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. ; Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) t~1 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. ^SIGNATURE ; DATE i7._ ,iOWNER-.BUlLDER;DECLARATIO"N ' : • „ " V " -'- '. »' '"' 1 ....... ,r ^ ^ ^ T .. ~. ... I hereby affirm that I am exempt from the Contractor's License Law for the following reason: l~l I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is solcfwithin one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). fr*iY\ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). (~1 I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. O YES l~lNO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): DATE ;iBUII|DINfi|PERMIiS|gjNLY_, _ „ _....„ _, . __ ._ Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? f~l YES l~l NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? [J YES fj] NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES Q NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 8^ „ CONS|RlMiONliiNDING AGENCY ^ - ,_ ' .. .-". "_' ~ „.-- -' " '„ „; '" :, : - ,,-.-_ - - - - I hereby affirm that there is a construptietfTending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME ^^^"^ LENDER'S ADDRESS 97 APPLICANT CERTIFiCATtdN ] . ." •" , „ ,7 ~ „". ~L ."." , ' . ' ,-..,,-; I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the data of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commp^fed )or a period of^wnT/rJSysTSecti/ff 106.4.4JJniform Building Code). APPLICANT'S SIGNATURE DATE YELLOW: Applicant PINK: Finance Carlsbad PC060028 7/24/O6 EsGil Corporation In Partners/Up with government for 'Building Safety DATE: 7/24/06 a 'JURIS.' JURISDICTION: Carlsbad b-PbWREViEWER a FILE PLAN CHECK NO.: PC060028 SET: III PROJECT ADDRESS: 2544 & 2548 Campbell Place PROJECT NAME: American Claims Management Office TI, Buildings A & B The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. ^ , The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. CH The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. CH The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: The mechanical and plumbing sheets of the plans must be signed by the design professional. By: Chuck Mendenhall Enclosures: Esgil Corporation D GA D MB D EJ D PC 7/13/06 trnsmtl.dot EsGil Corporation In Partnership with government for 'Building Safety DATE: 6/20/06 OAPPLICANT" JURISDICTION: Carlsbad Q PLAN REVIEWER .a FILE PLAN CHECK NO.: PC060028 SET: II PROJECT ADDRESS: 2544 & 2548 Campbell Place PROJECT NAME: American Claims Management Office TI, Buildings A & B ] The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I | The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Adair Interiors 3307 4th Ave., San Diego, CA 92103 I I Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Paula Stickney Telephone #: (619) 743-2870 Date contacted:6/2^/fcfe (by/^$ Fax #: (619) 312-1907 Mail Telephone Fa>^^ In Person REMARKS: The only thing we received was a set of electrical drawings for the generator. The attached list is identical to the previous one (dated 5/25/06), with added comments for the generator plans. By: Chuck Mendenhall Enclosures: Esgil Corporation • GA • MB D EJ D PC 6/12/06 . trnsmtl.dot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576 Carlsbad PC060028 "6/20/06 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK NO.: PC060028 PROJECT ADDRESS: 2544 & 2548 Campbell Place SET: II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED: ESGIL CORPORATION: 6/12/06 6/20/06 REVIEW ED BY: Chuck Mendenhall FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. B. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. C. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? QYes QNo Carlsbad PC060028 6/20/06 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Door A116 shown on sheet A-3.1 opening into the 1 HR rated corridor must be 20 min rated self closing. See the door schedule on sheet A-3.5. 2. Include a door note on sheet A-3.5 & A-3.6 that doors equipped with card reader security will be openable from the inside without the use of the card reader and upon power failure the card reader security system will be deactivated. 3. Note 7 on sheets A-4.1, 4.2, 4.3 & 4.4 indicates" Refer to sheet A-4 for suspended ceiling..." there is no sheet A-4. the suspended ceiling construction detail occurs in detail 137 A-10.1. Revise the general note referencing 13/A-10.1. 4. General note 14 on sheets A-4.1, 4.2, 4.3 & 4.4 indicates draft stops every 3000 sq ft, 100 ft max and references detail -/A-8.1. There is no draft stop construction detail found on sheet A- 8.1. Clarify where the detail can be found. Also, show on the reflected ceiling plans the location of the draft stops and reference the draft stop construction details to the location where it applies on the reflected ceiling plans. PLUMBING AND MECHANICAL CORRECTIONS t JURISDICTION: Carlsbad DATE: 5/23/06 • PLAN REVIEW NUMBER: PC060028 SET: I PLAN REVIEWER: Glen Adamek 1. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business and Professions Code. The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued. 2. Please provide statements on the Title Sheet of the plans stating compliance with current Code as follows: a) The 2001 edition of the California Building Code (CBC) adopts the 1997 Uniform Building Code (UBC) and the 2001 California Amendments. Carlsbad PC060028 6/20/06 b) The 2004 edition of the California Electrical Code (CEC) adopts the 2002 National Electrical Code (NEC) and the 2004 California Amendments. c) The 2001 edition of the California Mechanical Code (CMC) adopts the 2000 Uniform Mechanical Code (UMC) and the 2001 California Amendments. d) The 2001 edition of the California Plumbing Code (CPC) adopts the 2000 Uniform Plumbing Code (UPC) and the 2001 California Amendments. e) The 2001 edition of the California Fire Code (CFC) adopts the 2000 Uniform Fire Code (UFC) and the 2001 California Amendments. f) The 2005 edition of the California Energy Efficiency Standards. 3. Show the required ceiling rated fire dampers at duct openings in the fire rated ceiling membranes. UBC, Section 713.11 #4. 4. Provide data on proposed hazardous material to be stored and used. UBC, Section 307 and UFC. a) Clearly show types of hazardous material is being stored or used. Provide a list of the proposed hazardous materials as per the types in UBC, Tables 3-D, and 3-E. Provide the material safety data sheets (MSDS). b) Clearly show the amounts of each type of hazardous material to be stored and in use. c) Clearly show where in the buildings each type of hazardous material is being stored or used. PLUMBING (2000 UNIFORM PLUMBING CODE) 5. Correct the shower control valve and shower head locations to show compliance with UPC, Section 412.11. Shower head and shower control valves may not be on the back wall of the showers. 6. On the plans clearly show the sizes of the water meters. Then correct the pressure drops across the water meters as per the values from UPC, Chart A-1 used in the water line sizing calculations. 7. Potable water supply to carbonators shall be protected by either an airgap or a vented backflow preventer for carbonated beverage dispensers installed within the carbonated beverage dispenser. The carbonated beverage dispenser shall bear the label of an approved testing agency, certifying and attesting that such equipment has been tested and inspected, and meets the requirements of the approved applicable standard. Carbonated beverage dispensers without an approved internal airgap or vented backflow preventer for carbonated beverage dispensing systems shall have the water supply protected with a vented backflow preventer for carbonated beverage dispensers. As per UPC, Section 603.4.13 MECHANICAL (2000 UNIFORM MECHANICAL CODE) 8. In Groups B, F, M, and S Occupancies, or portions thereof, where Class I, II, or III-A liquids are used (in any amount), mechanical exhaust shall be provided sufficient to produce six air changes per hour. Such mechanical exhaust shall be taken from a point at or near the floor. UBC Section 1202.2.2. Carlsbad PC060028 6/&0/06 9. Detail exhaust ventilation system compliance with UMC Chapters 5 & 6. a) Clearly show the type of material to be exhausted by each exhaust system. b) Detail the exhaust outlet clearances as per UMC, Sections 504.5 (Environmental) & 506.9 (Product conveying). c) Detail the required make-up air as per UMC, Section 505.3. d) Detail ducts conveying explosives or flammable vapors, fumes or dusts shall extend directly to the exterior of the building without entering other spaces. UMC Section 505.1. e) Detail duct cleanouts as per UMC Section 506.3. f) Detail duct support as per UMC Sections 506.5 & 610.5. g) Detail fire protection as per UMC Sections 506.6 & 610.6. h) Detail clearances from combustibles as per UMC Sections 506.7 & 610.7. i) Detail protection from physical damage as per UMC Sections 506.8 & 610.8. 10. Exhaust ducts shall terminate outside the building as per UMC Sections 504.5 (Environmental) & 506.9 (Product-conveying). 11. Provide mechanical ventilation in all rooms capable of supplying outside air at a minimum rate of 15 cubic feet per minute per occupant. UBC Section 1202.2.1 12. Detail the access and working clearances to HVAC equipment. UMC Section 903 13. Show the minimum 30" deep unobstructed working space required for servicing in front of warm-air furnace. UMC Sections 903.0 and 908.0. 14. Detail the access opening for attics containing equipment as a minimum of 30" by 30". The opening may be reduced to 22" by 30" if the equipment can be removed through such opening. UMC Section 908.0 15. Provide smoke detection in the supply air duct of an "air-moving system" for required shut-off of equipment for smoke control. UMC Section 609.0. An "air-moving system" is a system designed to provide heating, cooling, or ventilation in which one or more air-handling units are used to supply air to a common space or to draw air from a common plenum or space. UMC Section 203.0. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. ELECTRICAL AND ENERGY CORRECTIONS PLAN REVIEWER: Morteza Beheshti • ELECTRICAL (2002 NATIONAL ELECTRICAL CODE) 1. Please provide receptacle(s) within 25 feet of all HVAC equipment. Specify weatherproof and GFI protection for the roof top units.NEC 210.8(b) 2 & 210.63. Carlsbad PC060028 6/&0/06 2. Please show or identify new loads proposed for the existing equipment. Also, the emergency loads are shown without the emergency source (shown to be under a separate contract). Emergency source and its load capacity must be verified for code compliance. 3. Indicate the total load demand on the service. 4. Provide the required access and entrance to working space for equipment rated 1200 amps or more and over 6 feet wide. NEC 110.26(c). 5. The emergency generator may not rely solely on a public gas system for its fuel supply or municipal water system for its cooling systems. NEC 700.12(b)(3) • ENERGY CONSERVATION 6. The energy forms are ok. Note: If you have any questions regarding this Electrical or Energy plan review list please contact Morteza Beheshti at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. ADDED COMMENTS FOR THE NEW GENERATOR PLANS: 7. Please show location of both services to this building and specify a common grounding electrode system. NEC 250.58 8. "Wiring from emergency source shall be kept entirely independent of all other wiring and equipment and shall not enter the same raceway, cable, box, or cabinet with other wiring." Only code recognized emergency loads may be connected to the emergency overcurrent device at the generator. NEC 700.9 9. Please show the available fault current from the serving utility co. at each service. 10. Please show the ampere interrupting capacity (AIC) ratings of the service and sub-service equipment. NEC 110.9 11. Please show or note on the plans the method used to limit fault currents on branch circuits. 12. Note on the single line diagram that all service disconnect devices shall be labeled as a "Service Disconnecting Means". On single line sheet E-7 the 200 amp. service disconnecting means should be labeled as service disconnecting means 4 of 4. NEC 230.70(b) 13. Include the following specifications on the single line diagram when utilizing a four pole ATS: The grounding electrode, conductor size, and the neutral bond at the generator (NEC 250-26), and both required signs installed at the service. NEC 700.8 (a & b) 14. Submit completed panel schedule(s) for all panels shown on single line(s). Carlsbad PC060028 6/20/06 15. Please provide receptacle outlet(s) within 25 feet of all HVAC equipment. Specify weatherproof and GFI protection for the roof top units. NEC 210.8(b) 2 & 210.63. 16. Indicate the total load demand on each service. 17. Please show the location of all panels, load centers, switchboards, generator and transformers. NEC 110.26, 240.24, 300.21. 18. Provide overcurrent protection on the secondary side of transformers. Please correct the conduit size for the transformer secondary ground system. NEC 240.21 Ex., 384.16(d). 19. Please specify secondary ground electrode system. NEC 250.30 20. Provide required transformer ventilation. NEC 450.9 21. The emergency generator may not rely solely on a public gas system for its fuel supply or municipal water system for its cooling systems. NEC 700.12(b)(3) 22. Please specify the location of the generator on floor plans. Shown on E-1 however, not clear if it's exposed to the weather? NEC 110.26 23. A room containing a combustion engine (or gas turbine) must be separated from the reminder of the building by a one-hour occupancy separation. CBC 413A.2.1 24. Openings into the generator room from the exterior must be protected (3/4 hr) if located within 10' of or below any openings in another story. CBC 413A.2.2 25. Note the following requirements on the prints for panelboards supplying fire alarm equipment: Lockable cover identified (red) circuit breaker, and the installation of a "lock off" device. 26. Provide multiple switch light controls so that the lighting can be reduced by one half in a uniform pattern. The switches must be located within sight of the lights which they control. CBC Title 24, Sec 131 a-b 27. Please show exit signs on the lighting plan(s) at all required exits and specify them as being self-luminous or having a second source of power (battery or generator). NEC 700.16. 28. Please provide a minimum of 1 foot-candle of emergency illumination at the floor level and specify a second source of power for the emergency illumination (battery or generator). UBC 1003.2.9.2 & NEC 700.16. 29. If utilizing a series-rated system, note on plans: "Overcurrent device enclosures will be identified as series-rated and labeled in accordance with NEC 110-22" and" The overcurrent devices shall be AIC rated per manufacturers, labeling of the electrical equipment". • ENERGY CONSERVATION 30. The corrected, completed and signed LTG-1-C, and MECH-1-C forms must be imprinted on the plans. Carlsbad PC060028 6/20/06 Note: If you have any questions regarding this Electrical or Energy plan review list please contact Morteza Beheshti at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. END OF REVIEW To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. EsGil Corporation In ^Partnership ziritfi. government for Quitting Safety DATE: 5/25/06 JURISDICTION: Carlsbad • PLAN CHECK NO.: PC060028 SET: I PROJECT ADDRESS: 2544 & 2548 Campbell Place PROJECT NAME: American Claims Management Office TI, Buildings A & B QAPPLICANT a PUN REVIEWER Q FILE The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. |~~1 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Adair Interiors 3307 4th Ave., San Diego, CA 92103 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Paula Stickney Telephone #: (619) 743-2870 Date contacted: S/<&7o (,(byd-fi3) Fax #: (619) 312-1907 Mail Telephone y/ Fax y\r\ Person REMARKS: By: Chuck Mendenhall Esgil Corporation • GA • MB D EJ Enclosures: PC 5/16/06 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 4 (858)560-1468 * Fax (858) 560-1576 Carlsbad PC060028 5/25/06 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: PC060028 JURISDICTION: Carlsbad OCCUPANCY: B USE: Office TI TYPE OF CONSTRUCTION: VN ACTUAL AREA: 47, 504 ft2 Each Bldg ALLOWABLE FLOOR AREA: no change STORIES: two HEIGHT: no change SPRINKLERS?: Yes OCCUPANT LOAD: 475 Each Bldg REMARKS: DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY JURISDICTION: ESGIL CORPORATION: 5/16/06 DATE INITIAL PLAN REVIEW PLAN REVIEWER: Chuck Mendenhall COMPLETED: 5/25/06 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot Carlsbad PCO6O028 5/25/06 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Door A116 shown on sheet A-3.1 opening into the 1 HR rated corridor must be 20 min rated self closing. See the door schedule on sheet A-3.5. 2. Include a door note on sheet A-3.5 & A-3.6 that doors equipped with card reader security will be openable from the inside without the use of the card reader and upon power failure the card reader security system will be deactivated. 3. Note 7 on sheets A-4.1, 4.2, 4.3 & 4.4 indicates " Refer to sheet A-4 for suspended ceiling..." there is no sheet A-4. the suspended ceiling construction detail occurs in detail 137 A-10.1. Revise the general note referencing 13/A-10.1. 4. General note 14 on sheets A-4.1, 4.2, 4.3 & 4.4 indicates draft stops every 3000 sq ft, 100 ft max and references detail -/A-8.1. There is no draft stop construction detail found on sheet A- 8.1. Clarify where the detail can be found. Also, show on the reflected ceiling plans the location of the draft stops and reference the draft stop construction details to the location where it applies on the reflected ceiling plans. PLUMBING AND MECHANICAL CORRECTIONS * JURISDICTION: Carlsbad DATE: 5/23/06 * PLAN REVIEW NUMBER: PC060028 SET: I PLAN REVIEWER: Glen Adamek 1, Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business and Professions Code. The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued. 2. Please provide statements on the Title Sheet of the plans stating compliance with current Code as follows: a) The 2001 edition of the California Building Code (CBC) adopts the 1997 Uniform Building Code (UBC) and the 2001 California Amendments. Carlsbad PC060028 5/25/06 , b) The 2004 edition of the California Electrical Code (CEC) adopts the 2002 National Electrical Code (NEC) and the 2004 California Amendments. c) The 2001 edition of the California Mechanical Code (CMC) adopts the 2000 Uniform Mechanical Code (UMC) and the 2001 California Amendments. d) The 2001 edition of the California Plumbing Code (CPC) adopts the 2000 Uniform Plumbing Code (UPC) and the 2001 California Amendments. e) The 2001 edition of the California Fire Code (CFC) adopts the 2000 Uniform Fire Code (UFC) and the 2001 California Amendments. f) The 2005 edition of the California Energy Efficiency Standards. 3. Show the required ceiling rated fire dampers at duct openings in the fire rated ceiling membranes. UBC, Section 713.11 #4. 4. Provide data on proposed hazardous material to be stored and used. UBC, Section 307 and UFC. a) Clearly show types of hazardous material is being stored or used. Provide a list of the proposed hazardous materials as per the types in UBC, Tables 3-D, and 3-E. Provide the material safety data sheets (MSDS). b) Clearly show the amounts of each type of hazardous material to be stored and in use. c) Clearly show where in the buildings each type of hazardous material is being stored or used. PLUMBING (2000 UNIFORM PLUMBING CODE) 5. Correct the shower control valve and shower head locations to show compliance with UPC, Section 412.11. Shower head and shower control valves may not be on the back wall of the showers. 6. On the plans clearly show the sizes of the water meters. Then correct the pressure drops across the water meters as per the values from UPC, Chart A-1 used in the water line sizing calculations. 7. Potable water supply to carbonators shall be protected by either an airgap or a vented backflpw preventer for carbonated beverage dispensers installed within the carbonated beverage dispenser. The carbonated beverage dispenser shall bear the label of an approved testing agency, certifying and attesting that such equipment has been tested and inspected, and meets the requirements of the approved applicable standard. Carbonated beverage dispensers without an approved internal airgap or vented backflow preventer for carbonated beverage dispensing systems shall have the water supply protected with a vented backflow preventer for carbonated beverage dispensers. As per UPC, Section 603.4.13 MECHANICAL (2000 UNIFORM MECHANICAL CODE) 8. In Groups B, F, M, and S Occupancies, or portions thereof, where Class I, II, or III-A liquids are used (in any amount), mechanical exhaust shall be provided sufficient to produce six air changes per hour. Such mechanical exhaust shall be taken from a point at or near the floor. UBC Section 1202.2.2. Carlsbad PCO6OO28 5/25/06 9. Detail exhaust ventilation system compliance with UMC Chapters 5 & 6. a) Clearly show the type of material to be exhausted by each exhaust system. b) Detail the exhaust outlet clearances as per UMC, Sections 504.5 (Environmental) & 506.9 (Product conveying). c) Detail the required make-up air as per UMC, Section 505.3. d) Detail ducts conveying explosives or flammable vapors, fumes or dusts shall extend directly to the exterior of the building without entering other spaces. UMC Section 505.1. e) Detail duct cleanouts as per UMC Section 506.3. f) Detail duct support as per UMC Sections 506.5 & 610.5. g) Detail fire protection as per UMC Sections 506.6 & 610.6. h) Detail clearances from combustibles as per UMC Sections 506.7 & 610.7. i) Detail protection from physical damage as per UMC Sections 506.8 & 610.8. 10. Exhaust ducts shall terminate outside the building as per UMC Sections 504.5 (Environmental) .& 506.9 (Product-conveying). 11. Provide mechanical ventilation in all rooms capable of supplying outside air at a minimum rate of 15 cubic feet per minute per occupant. UBC Section 1202.2.1 12. Detail the access and working clearances to HVAC equipment. UMC Section 903 13. Show the minimum 30" deep unobstructed working space required for servicing in front of warm-air furnace. UMC Sections 903.0 and 908.0. 14. Detail the access opening for attics containing equipment as a minimum of 30" by 30". The opening may be reduced to 22" by 30" if the equipment can be removed through such opening. UMC Section 908.0 15. Provide smoke detection in the supply air duct of an "air-moving system" for required shut-off of equipment for smoke control. UMC Section 609.0. An "air-moving system" \s a system designed to provide heating, cooling, or ventilation in which one or more air-handling units are used to supply air to a common space or to draw air from a common plenum or space. UMC Section 203.0. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. ELECTRICAL AND ENERGY CORRECTIONS PLAN REVIEWER: Morteza Beheshti • ELECTRICAL (2002 NATIONAL ELECTRICAL CODE) 1. Please provide receptacle(s) within 25 feet of all HVAC equipment. Specify weatherproof and GFI protection for the roof top units.NEC 210.8(b) 2 & 210.63. . Carlsbad PC060028 5/25/06 2. Please show or identify new loads proposed for the existing equipment. Also, the emergency loads are shown without the emergency source (shown to be under a separate contract). Emergency source and its load capacity must be verified for code compliance. 3. Indicate the total load demand on the service. 4. Provide the required access and entrance to working space for equipment rated 1200 amps or more and over 6 feet wide. NEC 110.26(c). 5. The emergency generator may not rely solely on a public gas system for its fuel supply or municipal water system for its cooling systems. NEC 700.12(b)(3) • ENERGY CONSERVATION 6. The energy forms are ok. Note: If you have any questions regarding this Electrical or Energy plan review list please contact Morteza Beheshti at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. END OF REVIEW To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. Carlsbad PC060028 5/25/06 VALUATION AND PLAN CHECK FEE ( Bldg A) JURISDICTION: Carlsbad PLAN CHECK NO.: PC060028 PREPARED BY: Chuck MendenhaU DATE: 5/25/06 BUILDING ADDRESS: 2544 & 2548 Campbell Place BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: V N BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq.Ft.) 47504 cb Valuation Multiplier 34.37 By Ordinance Reg. Mod. VALUE ($) 1,632,712 1,632,712 Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: Repetitive Fee Repeats Complete Review P Other i—i Hourly Structural Only Hour* Esgil Plan Review Fee $4,357.14 $2,832.14 $2,440.00 Comments: Sheet 1 of 2 macvalue.do Carlsbad PC060028 5/25/06 VALUATION AND PLAN CHECK FEE ( Bldg B) JURISDICTION: Carlsbad PLAN CHECK NO.: PC060028 PREPARED BY: Chuck Mendenhall DATE: 5/25/06 BUILDING ADDRESS: 2544 & 2548 Campbell Place BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: V N BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) 47504 cb Valuation Multiplier 34.37 By Ordinance Reg. Mod. VALUE ($) 1,632,712 1,632,712 Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: Repetitive Fee Repeats Complete Review D Other i—i Hourly Structural Only Hour* Esgil Plan Review Fee $4,357.14 $2,832.14 $2,440.00 Comments: Sheet2.of 2 macvalue.doc C itv of Carlsbad ib Wo r kff ?i-:1E n gin e e ring BUILDING PLANCHECK CHECKLIST DATE: BUILDING ADDRESS: PROJECT DESCRIPTION: ASSESSOR'S PARCEL NUMBER: g Co fa phut.'i V?r PLANCHECK NO.: CB EST. VALUE: ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. D A Right-of-Way permit is required prior to construction of the following improvements: DENIAL Please see the attached report of deficiencies marked with D. Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. Only the applicable sheets have been sent. By: By: By: Date: Date: Date: By: FOROFFICIAL USE ONLY iG AUTHORIZATION TO ISSUE BUILDING PERMIT: / / Date: ATTACHMENTS O Dedication Application D Dedication Checklist D Improvement Application D Improvement Checklist D Neighborhood Improvement Agreement D Grading Permit Application D Grading Submittal Checklist D Right-of-Way Permit Application Q Right-of-Way Permit Submittal Checklist and Information Sheet ENGINEERING DEPT. CONTACT PERSON Name: KATHLEEN M. FARMER City of Carlsbad Address: 1635 Faraday Avenue. Carlsbad, CA 92008 Phone: (760)602-2741 NOTE: If there are retaining walls associated with your project, please check with the Building Department if these walls need to be pulled by separate RETAINING WALL PERMIT. A-4 , CA 9200(8-7314 • (760) 602-272O • FAX (76O) BUILDING PLANCHECK CHECKLIST RD3 D D D SITE PLAN 1. Provide a fully dimensioned site plan drawn to scale. Show: A. North Arrow F. B. Existing & Proposed Structures G. C. Existing Street Improvements H. D. Property Lines (show all dimensions) I. Right-of-Way Width & Adjacent Streets Driveway widths Existing or proposed sewer lateral Existing or proposed water service E. Easements \~\ 2. Show on site plan: J. Existing or proposed irrigation service A. Drainage Patterns 1. Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. 2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5'away from building." B. Existing & Proposed Slopes and Topography C. Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project. Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception. D. Sewer and water laterals should not be located within proposed driveways, per standards. , 3. Include on title sheet: - A. Site address B. Assessor's Parcel Number C. Legal Description For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION Show all existing use of SF and new proposed use of SF. Example: Tenant Improvement for 3500 SF of warehouse to 3500 SF of office. F:\Farmer\Kalhy\MASTERS\Building Plancheok Oklsl Form (Generic).doc BUILDING PLANCHECK CHECKLIST 1ST 2NU 3- DISCRETIONARY APPROVAL COMPLIANCE D D D 4a. Project does not comply with the following Engineering Conditions of approval for Project No.. ' • ' • - D D D 4b. All conditions are in.compliance. Date: DEDICATION REQUIREMENTS D D 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 17.000 . pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: L__ '' • Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 7z x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by: Date: IMPROVEMENT REQUIREMENTS 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ 82,000 . pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the F:\Famner\KATHY\MASTERS\Building Plancheck Cklst Form (Generic).doc BUILDING PLANCHECK CHECKLIST ..ST 2ND 3RD D D d checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by: • Date: D D D 6b- Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $ 400.00 so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as follows: d d. d 6c- Enclosed please find your Neighborhood Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Neighborhood Improvement Agreement completed by: ' Date: D d D 6d- No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. d-d O 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill import, export and remedial). This information must be included on the plans. d d D 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: ' 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) F:\Farmer\KATHY\MASTERS\Buikling Plancheck Cklst Form (Generic).doc BUILDING PLANCHECK CHECKLIST ,.ST [H D CD 7d. No Grading Permit required. , D D D 7e. If grading is not required, write "No Grading" on plot plan. MISCELLANEOUS PERMITS D D D 8- A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-Way permit required for: _ • _ - D D 9- INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153, for assistance. Industrial Waste permit accepted by: ' Date: NPDES PERMIT D D D 10a- Storm Water Requirements Applicability Checklist Completed. L~H L~3 L~H 10b. Priority Determination and compliance: D Priority Project D Subject to Standard Permanent Storm Water BMP's D Exempt L~H D CH .11. D Required fees are attached D No fees required WATER METER REVIEW D D D 12a. Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized. Oversized meters are inaccurate during low-flow conditions. If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used. • All single family dwelling units received "standard" 1" service with 5/8" service. F:\Farmer\KATHY\MASTERS\Building Plancheck Cklsl Form (Generic).doc BUILDING PLANCHECK CHECKLIST 1ST 2ND gF D D • If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm). A typical fixture count and water demand worksheet is attached. Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit. • Maximum service and meter size is a 2" service with a 2" meter. • If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand, (manifolds are considered on case by case basis to limit multiple trenching into the street). 12b. Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval. The developer must provide these calculations. Please follow these guidelines: 1. If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets. If so, at the water meter station, the demand in gpm may be listed there. Irrigation services are listed with a circled "I", and potable water is typically a circled "W". The irrigation service should look like: STA 1+00 Install 2" service and 2. 3. 1.5: meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach). Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use. Once you have received a good example of irrigation calculations, keep a set for your reference. In general the calculations will include: • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA). As long as the project is located within the City recycled water F:\Farmer\Kathy\MASTERS\Buiiding Plancheck Cklst Form (GenericJ.doc BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future. fj D-D 12c- Irrigation Use (where recycled water is available) 1. Recycled water meters are sized the same as the irrigation meter above. 2. If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development. For .subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge. If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund. However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this. D D D 13. Additional Comments: F:\Farmer\Kathy\MASTEflS\Buiiding PJancheck Ckist t-orm (Generic).doc ^ a a ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET Estimate based on unconfirmed information from applicant. Calculation based on building plancheck plan submittal. Address:3L Bldg. Permit No.. Prepared by: lAJ. EDU CALCULATIONS: Types of Use: Or Types of Use: ADT CALCULATIONS: fijTypes of Use: O/K (J Types of Use: Date: '7/f(|^VJ Checked by: List types and square footages for all uses. "7 Sq. Ft./Units: r^fT- Cfljb^ Sq. Ft./Units: List types and square footages for all uses. i\ Sq. Ft./Units: r /J & I (to- U . Sq. Ft./Units: Date: EDU's: ^ EDU's: ADT's: r ADT's: •**> 6. 7O FEES REQUIRED: WITHIN CFD: [Z'YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) D NO 1. PARK-IN-LIEU FEE FEE/UNIT: PARK AREA & #: X NO. UNITS:.= $ D 2. TRAFFIC IMPACT FEE \~S a D a n a / v 'ADT's/UNITS: ' 3. BRIDGE AND THOROUGHFARE FEE ADT's/UNITS: 4. FACILITIES'MANAGEMENT FEE UNIT/SQ.FT.: 5. SEWER FEE 1 ^ <V 'EDU's: BENEFIT AREA: /' EDU's: /V-^S / 6. SEWER LATERAL ($2,500) 7. DRAINAGE FEES PLDA ACRES: X FEE/ADT: >^2 (DIST. #1 DIST. #2 X FEE/ADT: ZONE: X FEE/SQ.FT./UNIT: lOLp X FEE/EDUr^O^ : HIGH /LOW X FEE/AC: = $ -rfT^^ — ~ DIST. #3 . .) = $ ^^^^ -$ /^- ' X t7/£«3,6V '/ / J^i/M (, .(- ^9 ' l*'^)(, ^^ [([ ( -3n,Q jf^ / - $ .-r— f b U ^ ' ^ = '$ ^-^ -$ ^-^ D 8. POTABLE WATER FEES UNITS CODE CONNECTION FEE METER FEE SDCWA FEE IRRIGATION Wnrrl\Docs\Misforms\Fee Calculation Worksheet 1 of 2 Rev. 7/14/00 D D PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. PC060028 Planner Corey Funk APN: Address 2548 & 2544 Campbell PI. Phone (760)602-4645 Net Project Density: N/AType of Project & Use: Zoning: P-C General Plan: PI Facilities Management Zone: 17 DU/AC CFD (in/out) #J_Date of participation:.Remaining net dev acres:_ Circle One (For non-residential development: Type of land used created by this permit: ; ) Legend: Kl Item Complete Environmental Review Required: DATE OF COMPLETION: Item Incomplete - Needs your action YES /< NO _ TYPE Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: APPROVAL/RESO. NO. PROJECT NO. YES NO X TYPE. DATE OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: Q Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES_ CA Coastal Commission Authority? YES NO ;x NO ' If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? YES NO If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: D D Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 2) Complete Coastal Permit Determination Log as needed. Inclusionary Housing Fee required: YES NO AT (Effective date of Inclusionary Housing Ordinance - May 21,1993.) Data Entry Completed? YES NO * (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 <* Site Plan: , ' £3 O O 1- Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). 0 [H [I] 2. Provide legal description of property and assessor's parcel number. DD an CD Policy 44 - Neighborhood Architectural Design Guidelines 1. Applicability: YES. 2. Project complies YES Zoning: 1 . Setbacks: Front: Interior Side: Street Side: Rear: Top of slope: 2. Accessory structure setb Front: Interior Side: Street Side: Rear: Structure separation: 3. Lot Coverage: NO Required Required Required Required Required lacks: Required Required Required Required Required Required Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown DD n n 4. Height:Required Spaces Required. Shown Shown5. Parking: (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required ' Shown Additional Comments OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 Carlsbad Fire Department DEPT"COPY Plan Review Requirements Category: PLANCK, Date of Report: 06-20-2006 Reviewed by: Name: Address: Permit #: PC060028 Job Name: ARROWHEAD GEN INSURANCE-2 ITS Job Address: 2544 CAMPBELL PL CBAD The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond: CON0001368 ETJBUILDING # A and B. Shall provide emergency evacuation signs in accordance with Title 19 secuon5.09 / Shall submit sign package for approval by fire department prior to installation. BUILDING # A. The Lunch room B147 is listed as an A-2.1 occupant. This does not meet definition of the CBC Section 303.1.1. Please resubmit description of lunch room B147. Approved: This project has been reviewed and approved for the purpose of issuance of a building permit. This approval is subject to field inspections, any required test, fire department notations, conditions in correspondence and compliance with all applicable codes and regulations. This approval shall not be to held to permit or approve the violation of any law. Entry: 05/23/2006 By: JV Action: AP Cond: **APPROVEDjTHIS PROJECT HAS BEEN REVIEWED AND API lUUl'viULI FT5R THE PURPOSES OF ISSUANCE OF BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. Entry: 06/20/2006 By: GR Action: AP Carlsbad Fire Department v Plan Review Requirements Category: PLANCK, Date of Report: 05-23-2006 Reviewed by: Name: PAULA STICKNEY ' Address: 9696 WAYFARER LA MESA CA 91942 Permit #: PC060028 Job Name: ARROWHEAD GEN INSURANCE-2 TI'S Job Address: 2544 CAMPBELL PL CBAD INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions; Cond: CON0001368 [MET] BUILDING # A and B. Shall provide emergency evacuation signs in accordance with Title 19 section 3.09 / Shall submit sign package for approval by fire department prior to installation. BUILDING # A. The Lunch room B147 is listed as an A-2.1 occupant. This does not meet definition of the CBC Section 303.1.1. Please resubmit description of lunch room B147. Approved: This project has been reviewed and approved for the purpose of issuance of a building permit. ' This approval is subject to field inspections, any required test, fife department notations, conditions in correspondence and compliance with all applicable codes and regulations. This approval shall not be to held to permit or approve the violation of any law. Entry: 05/23/2006 By: JV Action: AP HANDLEY ENGINEERING 130EICaminoReal#200 Tustin, CA 92780 714-669-1141 Page! Job No: 06-08 Date: 07-06-06 STRUCTURAL CALCULATIONS (OVERTURNING) FOR NEWKOHLER GENERATOR FOR ARROWHEAD GENERAL INSURANCE LOT 16, BRESSE RANCH, CARLSBAD, CA CONTRACTOR: McBRIDE ELECTRIC 9950 Scripps Lake Drive Suite 104 San Diego, CA 92131 858-560-1900 HANDLEY ENGINEERING 130 El Camino Real #200 Tustin, CA 92780 714-669-1141 Page Job No. Date: •Off. KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-565-3381, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KohlerPowerSystems.com Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455 Standard Features and Accessories Additional Standard Features • Alternator Protection (standard with 550 controller) • Oil Drain Extension • Operation and Installation Literature Accessories Open Unit Q Exhaust Silencer, Critical a a a Kits: PA-354880, PA-365337, PA-365348, PA-365353 Exhaust Silencer, Hospital Kits: PA-354905, PA-365343, PA-365349, PA-365354 Exhaust Silencer, Industrial Kits: PA-354904, PA-365340, PA-343617, PA-365350 Exhaust Silencer, Residential Kits: PA-3549882, PA-365334, PA-365347, PA-365352 Q Rexible Exhaust Connector, Stainless Steel Q Sound Enclosure (with roof-mounted hospital silencer) Q Weather Enclosure (with roof-mounted critical silencer) Cooling System Q Block Heater Q Radiator Duct Flange Q Remote Radiator Cooling Fuel System Q Flexible Fuel Lines Q Fuel Filter Q Fuel Pressure Gauge Q Subbase Fuel Tank with Day Tank Electrical System Q Battery Q Battery Charger, Equalize/Roat Type Q Battery Heater Q Battery Rack and Cables Engine and Alternator Q Air Cleaner, Heavy Duty Q Air Oeaner Restriction Indicator Q Alternator Strip Heater Q Bus Bar Kits (standard on 7M alternators, 380-600 volt only) [_) Line Circuit Breaker (NEMA type 1 enclosure) Q Line Circuit Breaker with Shunt Trip (NEMA type 1 enclosure) Q NFPA 110 Literature Q Optional Alternators Q Rated Power Factor Testing Q Safeguard Breaker (not available with 550 controller) Paralleling System Q Load-Sharing Module Q Reactive Droop Compensator Q Remote Speed Adjust Control/Electronic Governor (550 controller only) Q Voltage Adjust Control Q Voltage Regulator Relocation Kit Maintenance Q General Maintenance Literature Kit Q Maintenance Kit (includes air, oil, and fuel filters) Q Overhaul Literature Kit Q Production Literature Kit Controller Q Common Failure Relay Kit Q Communication Products and PC Software (550 controller only) Q Customer Connection Kit Q Dry Contact Kit (isolated alarm) Q Engine Prealarm Sender Kit Q Prime Power Switch (550 controller only) Q Remote Annunciator Panel Q Remote Audiovisual Alarm Panel Q Remote Emergency Stop Kit Q Remote Mounting Cable Run Relay Kit Miscellaneous Accessories a aaaQaa Q Q Dimensions and Weights Overall Size, max., Lx Wx H, mm (in.): 60 Hz, 40°C (105°F): 3647 x 1270 x 2050 (143.58 X 50.00 x 80.70) 60 Hz, 50°C (122°F): 3647 x 1270 x 2144 (143.58 X 50.00 x 84.41) 50 Hz, 50°C (122°F): 3647 x 1270 x 2050 (143.58 X 50.00 x 80.70) Weight, radiator model, max. wet, kg (Ib.): 4000 (8820) -^-* H i ,_j a a NOTE: TOs drawing is provided for reference orty and should not be used for planning installation. Contact your local distributor for more detailed information. DISTRIBUTED BY: a 1998, 1999. 2000, 2001, 2002, 2003. 2005 by Kohler Co. All rights reserved. GS-158 (4SOREOZD-4) 12/OSp Model: 450REOZD-4 KDHLERPOWER SYSTEMS 190-600V 4-Cycle Diesel $9001 NATIONMtr REGISTERED Ratings Range 60 Hz 50 Hz Standby: kW 400-460 364-408 kVA 500-575 455-510 Prime: kW 365-420 328-368 kVA 456-525 410-460 Generator Set Ratings Alternator 5M4024 5M4027 5M4028 / 5M4160 5M4162 5M4270 Voltage 120/208 127/220 139/240 220/380 240/416 277/480 110/190 115/200 120/208 220/380 230/400 240/416 120/208 127/220 139/240 220/380 240/416 277/480 110/190 115/200 120/208 220/380 230/400 240/416 120/208 127/220 139/240 220/380 240/416 277/480 110/190 115/200 120/208 220/380 230/400 240/416 220/380 220/380 347/600 Ph 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Hz 60 60 60 60 60 60 50 50 50 50 50 50 60 60 60 60 60 60 50 50 50 50 50 50 60 60 60 60 60 60 50 50 50 50 50 50 60 60 60 150°CRise StandbyRatingkwykVflV 450/563 450/563 450/563 400/500 450/563 450/563 400/500 400/500 380/475 400/500 400/500 380/475 450/563 450/563 450/563 405/506 450/563 450/563 400/500 400/500 400/500 400/500 400/500 400/500 455/569 455/569 455/569 455/569 455/569 455/569 408/510 408/510 408/510 408/510 408/510 408/510 450/563 450/563 450/563 130°CRise StandbyRating kW/kVA 440/550 450/563 450/563 400/500 440/550 450/563 400/500 388/485 364/455 400/500 388/485 364/455 450/563 450/563 450/563 405/506 450/563 450/563 400/500 400/500 400/500 400/500 400/500 400/500 455/569 455/569 455/569 455/569 455/569 455/569 408/510 408/510 408/510 408/510 408/510 408/510 450/563 450/563 450/563 125°CRise PrimeRatingkW/kVA 410/513 410/513 410/513 365/456 410/513 410/513 364/455 364/455 352/440 364/455 364/455 352/440 410/513 410/513 410/513 370/463 410/513 410/513 364/455 364/455 364/455 364/455 364/455 364/455 415/519 415/519 415/519 415/519 415/519 415/519 368/460 368/460 368/460 368/460 368/460 368/460 410/513 410/513 410/513 105°CRise PrimeRating kW/kVA 410/513 410/513 410/513 365/456 410/513 410/513 364/455 360/450 328/410 364/455 360/450 328/410 410/513 410/513 410/513 370/463 410/513 410/513 364/455 364/455 364/455 364/455 364/455 364/455 415/519 415/519 415/519 415/519 415/519 415/519 368/460 368/460 368/460 368/460 368/460 368/460 410/513 410/513 410/513 Standard Features • Kohler Go. provides one-source responsibility for the generating system and accessories. • The generator set and its components are prototype-tested, factory-built, and production-tested. • The 60 Hz generator set offers a UL 2200 listing. • The generator set complies with ISO 8528-5, Class G3, requirements for transient performance. • The generator set accepts rated load in one step. • A one-year limited warranty covers all systems and components. Two-, five-, and ten-year extended warranties are also available. • Alternator features: o The brushless, rotating-field alternator has broadrange reconnectability. o The pilot-exerted, permanent-magnet (PM) alternator provides superior short-circuit capability. • Other features: o Controllers are available for all applications. See controller features inside. o The low coolant level shutdown prevents overheating (standard on radiator models only). o Integral vibration isolation eliminates the need for under-unit vibration spring isolators. o An electronic, isochronous governor delivers precise frequency regulation. o Electronic engine controls and a generator set microprocessor controller combine to deliver one of the most advanced control systems in today's market. 5M4272 347/600 3 60 460/575 460/575 420/525 420/525 RATINGS: All Ihre&phase units are rated at 0.8 power factor. Standby Ratings: Starefcy ratings apply to installations served by a reliable uHity source The standby rating is applicable to varying loots far the duration of a power outage. There is no overload capabJity for this rating. Ratings are in accordance with BO-30WI, BS 5514, AS 2789. and DIN 6271. PrtnePomr Ratings: Prime power ratings apply to instalafans where ufflily power is unavailable or unreliable At varying toad, the number of generatorse* operating hours is unlimited A10% overload capadty is avajatte for one hour in twelve. Ratings are in acccrtaro «^ ISO-8528/1, overbad power in accordance win 6O-304W1, BS 5514, AS 2789, and DIN 6271. For lirrtted running time and base load ratings, const* the factory. Obtain Ihe lectrncai Wcmieijon b^rtn (TB-101) on ratr^ gukkiines fa tr» ornptete rab^ The generator set manufacturer reserves the rigrt to change the design or specifications without notice and wSnout any obligation or liability whatsoever. GENERAL GUIDELINES TOR DERATION: AtOuOe: Deme 0.5% per 100 m (328 ft.) elevation above 1000 m (3280IL) Maximum altitude capeMty is1880m (6102 ft). Temperature. Derate 1.0% per 10°C (18'F) lemperahre above 25°C (77-F). G5-1S9 (450REOZTM) 12/OSp DRAFT June 192007 . RICKCALHOUN • ARROWHEAD GENERAL INSURANCE AGENCY INC. 6055LUSKBLVD SAN DIEGO CA 92121 After examination of Application No. 985443 for an Air Pollution Control District (District) Authority to Construct / Permit to Operate for an emergency engine, driving a fire pump, to be located at 2548 Campbell Place Carlsbad CA 92009, the District has decided on the following action: Authority to Construct is granted pursuant to Rule 20 of the Air Pollution Control District Rules and Regulations for: An emergency standby engine: One (1) 685 BHP Detroit Diesel Model 6063- HV35 4- cycle Diesel fired Engine, with Turbocharging and Aftercoojing, driving a450 kW Kohler Model 450REOZDD generator. EPA Tier 111 Family No. 7DDXL14.0VLD . This Authority to Construct is granted with the following conditions: 1. This Authority to Construct shall be posted on or within 25 feet of the engine, or maintained readily available at all times on the operating premises. 2. Engine operation for maintenance and testing purposes shall not exceed 50 hours per calendar year. (17 CCR 93115) (ATCM reportable) 3. This engine shall only use CARB diesel fuel. Records of CARB diesel fuel certification shall be maintained on-site and made available to District personnel upon request. (Rule 69.4.1, 17 CCR 93115) 4. Visible emissions including crank case smoke shall comply with Air Pollution Control District Rule 50. (Rule 50) 5. The equipment described above shall not cause or contribute to a public nuisance. : (Rule 51) 6. This engine shall not operate for non-emergency use during the following periods, as applicable: Arrowhead General Insurance . Application No. 985443 June 19,2007 -2- ' a. Whenever there is any school sponsored activity, if engine is located on school grounds or b. Between 7:3 Oam and 3:30pm on days when school is in session, if the engine is located within 500 feet of, but not on, school grounds. This condition shall not apply to an engine located at or near any school grounds that also serve as the students' place of residence. (17 CCR 93115) (ATCM reportable) 7. . A non-resettable engine hour meter shall be installed on this engine, maintained in good working order, and used for recording engine operation hours: If a meter is replaced, the Air Pollution Control District's compliance division shall be notified in writing within 10 calendar days. The written notification shall include the following information: a. Old meter's hour reading. b. Replacement meter's manufacturer name, model and serial number if available and current hour reading on replacement meter, c. Copy of receipt of new meter or of installation work order. A copy of the meter replacement notification shall be maintained onsite and made available to the Air Pollution Control District upon request. (Rule 69.4.1, 17 CCR 93115) 8. The owner or operator this engine shall conduct periodic maintenance of the ' engine and add-on control equipment, if any, as recommended by the engine and control equipment manufacturers or as specified by the engine servicing company's maintenance procedures. The periodic maintenance shall be conducted at least once each calendar year. (Rule 69.4.1) 9. The owner or operator of the engine shall maintain the following records on site for at least the same period of time as the engine to which the records apply is located at the site: a. Documentation shall be maintained identifying the fuel as CARB diesel. b. Manual of recommended maintenance provided by the manufacturer, or maintenance procedures specified by the engine servicing company; and c. Records of annual engine maintenance including date the maintenance was performed. These records shall be made available to the Air Pollution Control District upon request. (Rule 69.4.1)( 17 CCR 93115) 10. The owner or operator of this engine shall maintain a monthly operating log containing, at a minimum, the following: a. dates and times of engine operation whether the operation was maintenance and testing purposes or emergency use; and the nature of the emergency, if known; Arrowhead General Insurance Application No. 985443 June !<•), 2007 . -3- b. hours of operation for all uses other than those specified above and identification of the nature of that use. (Rule 69.4.1, CCR 93115) 11. The owner or operator shall document fuel use through the retention of fuel purchase records that account for all fuel used in the engine and all fuel purchased for use in the engine, and, at a minimum, contain the following information: a. amount of fuel purchased b. date when the fuel was purchased c. signature of owner or operator or representative of owner or operator who received the fuel. . d. signature of fuel provider indicating fuel was delivered; e. amount of fuel added to the engine tank.(17 CCR 93115) 12. All operational and maintenance logs and fuel use and type and purchase records required by this permit shall be kept for a minimum of 36 months from their date of creation unless otherwise indicated by the conditions of this permit. The records shall be maintained onsite for a minimum of 24months from their date of creation. Records for the last 24 months of operations shall be made available to t^e Air Pollution Control District upon request. Records for operation for the last 25 to 36 months shall be made available to the Air Pollution Control District within 5 working days of request. (69.4.1, 17 CCR 93115) 13. The permittee shall notify the Air Pollution Control District compliance division immediately upon detection of any violation of a condition identified as "ATCM Reportable". Such violations shall be subject to Air Pollution Control District Compliance action.( 17 CCR 93115) 14. Engine operation in response to notification of an impending rotating outage, shall be subject to all the following restrictions: a. The utility distribution company has ordered rotating outages in the control area where the engine is located. b. The engine is operated no more than 30 minutes prior to the time when the utility distribution company officially forecasts a rotating outage in the cited control area, and ' c. The engine operation is terminated immediately after the utility distribution company advises that a rotating outage is no longer in effect. This condition shall not apply to engines operating pursuant to the .rolling blackout reduction program as defined in 17 CCR 93115 and operating in accordance with 17 CCR 93115(e)(2)(f). (17CCR93115)(ATCMreportable) 15. The exhaust stacks shall be vertical at the exhaust exit point. Vertical exhaust flow shall be unrestricted. A flapper valve may be installed on the exhaust stacks. Arrowhead General Insurance Application No. 985443 . ,June 19,2007 -4- 16. This Authority to Construct authorizes temporary operation of the above-specified unit. This temporary Permit to Operate shall take effect upon written notification to the District that construction has been completed in accordance with this ' Authority to Construct. This temporary Permit to Operate will remain in effect, unless withdrawn or modified by the District until the unit is inspected by the District and a revised temporary permit (Startup Authorization) is issued or a Permit to Operate is granted or denied. 17. Upon completion of construction in accordance with this Authority to Construct and prior to commencing operation, the permittee must complete and mail, deliver or fax the enclosed Construction Completion Notice to the District. Applicant shall also state the serial number of the unit on the notice or attachment. After mailing, delivering or faxing the Notice, the permittee may commence operation .' of the unit. Operation must be in compliance with all of the conditions of the Authority to Construct and Applicable District Rules. This Air Pollution Control District Authority to Construct does not relieve the holder from obtaining permits or authorizations, which may be required by other governmental agencies. Within thirty (30) days after receipt of this Authority to Construct, the permittee may petition the Hearing Board for a hearing on any conditions imposed herein in accordance with Rule 25. v,1 This Authority to Construct is not transferable and will expire 1 year from the date of this letter unless an extension is requested in writing. If you have any questions regarding this action, please contact the undersigned at (858)586-2743. EARNEST A. DAVIS, PE Associate Air Pollution Control Engineer EAD:ed Enclosure cc: Compliance Division I.D;#: 2.0/112.45 A I I RANCH GORPORATI V ' ":" JEER* l'.STE. 200 , » , • . (i i AMINATE TREATED ' 1 , UN STEEL . LI 3MINED FIED BUILDING DATA PROJECT ADDRESS- BUILDING A - 2548 CAMPBELL PLACE BUILDING B - 2544 CAMPBELL PLACE TYPE OF CONST. V N. FULLY SPRINKLERED OCCUPANCY. B - OFFICE ZONE. PM - PLANNED INDUSTRIAL NO. OF STORIES- 2 DESCRIPTION OF WORK- NEW T.I.- OFFICE Q/ ^/ m £wf -i/tJ^ SQUARE FOOTAGE* BUILDING A -//IST FLR. 23,729 - '" • 2ND FLR" 23.775 47,504 BUILDING B - 1ST FLR> 23.729 _ 2ND FLR.. 23.775 47,504 TOTAL* A & B- 95,008 PARKING- 318 STANDARD, 87 COMPACT 10 DISABLED ACCESSIBLE (2 VAN ACCESSIBLE) ASSESSOR'S PARCEL- 213-260-07 LEGAL DESCRIPTION. LOT 16 OF MAP NO. 14960 IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA. -. PROJECT SCOPE TENANT IMPROVEMENTS TO INCLUDE: I. CONSTRUCTION OF NEUJ NON-BEARING PARTITIONS 2. NEW MECHANICAL < TITLE 24 3. NEW ELECTRICAL < TITLE 24 4. NEUJ PLUMBING &. NEUJ CEILING AND LIGHTS ' 6. NO STRUCTURAL REQUIRED s A A A A A A A A- A- A- A- A- A- A- A- A- A-i A-i AH A-( A-e A-C A-6 A-7 A-7 A-8 A-9 A-8 A-1! MEI MO. MO. MO. MO. MO. M2. M2. M2. M2. M2•»• fm* M2. M3. M3. M3. M3. M5. PLL P0.1 pn • I I V—f I RANCH CORPORATE •pfNGINFFRi |p I MSfe*^^'mjjix.''m•PNARDD, STE. 200 IB&'-if P •Ppp^f •• RK: •P'1B^HlP*-" •s?''^'1 IP 'Up-lp •S3- VIP-IPKIP•fpwIF•swT; H}jK$d?V ,-, life KCftSTIC LAMINftTE HffeUYVnaD •PAIR•fWESSURE TREATED KrDI JAUTTT VMr iiUnn 1 1 1 T•tn "-vV • ISaaF DRAINPREFERENCE Wsa.ni CORE ^SCHEDULE KSHEET ISIMILAR iSPECIFICATIDNISOUARE ISTAINLESS STEEL iSTANDARH{STORAGE^SUSPENDEDISCET VINYL ITD BE DETERMINED |ra BE SPECIFIED pLEPHDNEIDIPDRARYiTHrrvnmuKIYPICAL BUILDING DATA PROJECT ADDRESS- BUILDING A - 2548 CAMPBELL PLACE BUILDING B - 2544 CAMPBELL PLACE TYPE OF CONST- V N, FULLY SPRINKLERED i OCCUPANCY- B - OFFICE ZONE- PM - PLANNED INDUSTRIAL NO. OF STORIES- 2 DESCRIPTION OF WORK- NEW T.I.- QFFICfi SQUARE FOOTAGE- B"UILDING A -//1ST FLR- 23,729 • ' 2ND FLR. 23.775 47,504 BUILDING B - 1ST FLR- 23.729 _ 2ND FLR.. 23.775 47,504 TOTAL- A & B- 95,008 PARKING- 318 STANDARD, 87 COMPACT 10 DISABLED ACCESSIBLE (2 VAN ACCESSIBLE) ASSESSOR'S PARCEL- 213-280-07 LEGAL DESCRIPTION. LOT 18 OF MAP NO. 14980 IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA. PROJECT SCOPE TENANT IMPROVEMENTS TO INCLUDE: I. CONSTRUCTION OF NEUJ NON-BEARING PARTITIONS 2. NEUJ MECHANICAL 4 TITLE 24 3. NEW ELECTRICAL < TITLE 24 4. NEUJ PLUMBING 5. NEUJ CEILING AND LIGMT6 6>. NO STRUCTURAL REQUIRED , SHEET ARCHITEC A-1.0 A-1.1 A-1.2 A-2.1 A.Q O I£.£ I A-3.1 1 A-3.2 1 A-3.3 1 A-3.4 1 A-3.5 1 A-3.6 I A-3.7 L A-4.1 E A-4.2 E A-4.3 E A-4.4 B A-5.1 B A-5.2 B A-5.3 B A-5.4 B A-8.1 B A-8.2 B A-6.3 B A-6.4 B A-7.1 Ri A-7.2 SI SI A-8.1 C< A-9.1 LC A-9.2 Ol A-10.1 C< MECHANICAL M0.1 NOTE M0.2 MECH M0.3 MECH M0.4 EXIST M0.5 TITLE M2.1 BUILD M2.2 BUILD M2.3 BUILD M2.4 BUILD M2 5 BUILDI•«••** LJ^^IkVI M2.6 BUILDI M3.1 BUILDI M3.2 BUILDI M3.3 BUILDI M3.4 BUILDI M5.0 MECH, PLUMBING PL P0.1 NOTEJt>n o or*i "•" & ,§ NI*tf ^S^c sxs'oo ur i •o-ou yv) •/ c=f<2 fc . fes *11 IS Jill g|illlless~ ^ "T* 1 — . >~ fj K ~ - | 3» mg-g W -Nj ^S^a^|£JWte 3 ^ c^piSlfSoSo" 3 ^ S'NrQQ ? <v V '^' $•<| a :\J 3Sv< 3^Silg js Vs ^Slig^s -y -i^K535! ^ S'c- "r5-<^sr/ ^^*s. .f''*^"^ ••$I <5 \^ \Sf 2 i £ O \ ' s> 1 J- >^ O\X^ ^ •^ \ ^^ ^ .1 : s 'in' Jfe ^ 2> ^ -i. e^21 s- ^ ^>^> ^^y .^ ^ ^^T ? ^ V<4 ^^sJjO 0 /\ ^V ^ J ' -A V X^ «; ;>£ 3 ^' •< ^> ^ \ $ ^3 ^ ^J i* *I 18|§pw|a|g!&§§ii^Ol OJiS^cD fl* Ul Ul £LilDJ i ijJ.^l ?>v3'^:- <i CT ^* e| j. ^_ 30: in " t * ^£ 1 1 ^ ^ ^ -v€ r^ 0 ^ -C^v ^ ^ 4 £0^ f-^.1 v v . J^ OP1 J? _i^ "^ ^~ ^^ ^ ^^ \^ S vn ^L 11 ^ ^ S ^~w ^ 3 s -^^_ ^ vx CL , ^ 5^4< <=^- V) ^v. 8 > K ,c^ -^^ ^-.s J I e- ^•«J ^ t 5s ^ \ ' ? >, » ^ 5 ^ t 1 41 5 § "^ ^ ^ A ^J i ^3 \5 *1 ^1 § </s« ^ ^ t ^ -? °>~~ f . ' <r Q ^"r- X \ <&o