Loading...
HomeMy WebLinkAbout2550 EL CAMINO REAL; ; CBC2020-0244; PermitBuilding Permit Finaled Commercial Permit Print Date: 10/16/2020 Job Address: PermitType: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: ProjectTitle: 2550 EL CAMINO REAL, BLDG-Commercial 1670305000 $90,000.00 CARLSBAD, CA 92008-1201 Work Class: Tenant Improvement Track#: Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Description: BANK OF AMERICA: EXTERIOR IMPROVEMENTS OF EXISTING BANK Applicant: JUDY YAM 392 N LE MAY CT ORANGE, CA 92867-7628 (626) 675-9882 FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) Property Owner: CARLSBAD PLAZA LIMITED GEOFF REESLUND PO BOX8700 NEWPORT BEACH, CA 92658 (949) 759-9531 x24 SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-COMMERCIAL Total Fees: $1,020.64 Total Payments To Date: $1,020.64 {city of Carlsbad Permit No: CBC2020-0244 Status: Applied: Issued: Finaled Close Out: Inspector: Final Inspection: Balance Due: Closed -Finaled 06/22/2020 08/31/2020 TAlva 10/16/2020 AMOUNT $583.20 $408.24 $4.00 $25.20 $0.00 Please take NOTICE that approval of your project includes the 11lmposition11 of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560! I www.carlsbadca.gov {cicyof Carlsbad Job Address 2550 El Camino Real Tenant Name/3ank of America (Existing) COMMERCIAL BUILDING PERMIT APPLICATION 8-2 CBC2020-0244 Plan Check --------- Est. Value $ 90,000. PC Deposit --------- Date {)y/z_ 2 /2-02-D Suite: _Ni_A ___ APN: ________ _ CT/Project#: _______ Lot#: ___ _ Occupancy: B-Bank Construction Type:....:V_-.=Bc__ __ Fire Sprinklers: 0 YES 0 NO Air Conditioning: 0 YES O NO BRIEF DESCRIPTION OF WORK: Exterior finishes improvement to (E) B of A with new paint. No change in bldg height, no added sf, & no change in facade. Removed (E) palm trees/ dead or poor quality planting and replaced with low water use plants. D Addition/New: ___________ New SF and Use, __________ New SF and Use, _____ Deck SF, Patio Cover SF (not including flatwork) [Z] Tenant Improvement: _N_/_A ____ SF, Existing Use (E) Bank Proposed Use _B_a:....__n_k ___ _ ______ SF, Existing Use _______ Proposed Use ______ _ D Pool/Spa: _____ SF Additional Gas or Electrical Features? ____________ _ □ □ Solar: ___ KW, __ Modules, ___ Mounted, Tilt: QYQN, RMA: Q YQ N, Panel Upgrade: QY QN Plumbing/Mechanical/Electrical Only: _________________________ _ D Other: No interior work. Exterior finishes, and landscape improvement only. Signage replacement under a separate permit. APPLICANT (PRIMARY CONTACT) Name: Judy Yam Address: 392 N. Le May Court City: Orange State:_C_A __ .Zip: 92867 Phone: 626.675.9882 Email: meiyeeyam@sbcglobal.net DESIGN PROFESSIONAL Name: Sergio Rivas Address: 4675 MacArthur Court, Ste 100 City: Newport Beach State: CA Zip: 92867 Phone: 949.863.9434 Email: ________________ _ Architect State License: ___________ _ PROPERTY OWNER Name: Carlsbad Plaza, LLC Address: P.O. Box 8700 City: Newport Beach Phone: 949.759.9531 State: CA Zip: 92660 Email: ____________________ _ CONTRACTOR BUSINESS Name: ASI Anthony &Sons General Contractors, Inc. Address: 4061 Seaport Blvd City: Wear Sac State: Ca Zip: ..:.9..:.5-'-69.;_1 ___ _ Phone: 916-373-0707 Email: Aalfrey@asigc.com State License: 360117 Bus. License: 15Lo5o{:g '.¼.S-- (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov B-1 Page 1 of 2 Rev. 03/20 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: 01 have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. ~ I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: _IC_W_G_r_ou~p~----------------- Policy No. WSA5037782 02 Expiration Date: _1_0_11_12_0_2_0 _____ _ D Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for In Section 3706 of the Labor Code, interest and attorney's fees. CONTRACTOR SIGNATURE:A'_dA.4: __ n,_A'....;...~,4-~F------------LJAGENT DATE: A,,."· 2020 ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: DI, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). DI, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). DI am exempt under Section _______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. QYES ONO 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work): OWNER SIGNATURE: __________________ □AGENT DATE: _____ _ CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: _____________________ lender's Address: ____________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes/ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Yes/ No ls the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes/ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. 1 ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 360 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (AB2913). APPLICANT SIGNATURE: ___ J_u_dy_Ya_m _______________ DATE: _0_8_-3_0_-2_0 ____ _ 1635 Faraday Ave Carlsbad, CA 92008 B-1 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of 2 Email: Building@carlsbadca.gov Rev. 03/20 Building Permit Inspection History Finaled {city of Carlsbad Permit Type: Work Class: Status: Scheduled Date 10/16/2020 PERMIT INSPECTION HISTORY for (CBC2020-0244) BLDG-Commercial Application Date: 06/22/2020 Owner: CARLSBAD PLAZA LIMITED Tenant Improvement Issue Date: 08/31/2020 Subdivision: Closed -Finaled Expiration Date: 08/31/2021 Address: 2550 EL CAMINO REAL IVR Number: 27030 CARLSBAD, CA 92008-1201 Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Start Date Status BLDG-18 Exterior 141128-2020 Scheduled Tony Alvarado Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-Final Inspection 141127-2020 Passed Tony Alvarado Checklist Item BLDG-Structural Final COMMENTS October 16, 2020: 1. Final inspection for exterior stucco lath patch scope of work-approved. 2. Final completion of damaged stucco scope of work-approved. Passed Yes Friday, October 16, 2020 Inspection Incomplete Complete Page 1 of 1 I EsGil DATE: 7/07/2020 JURISDICTION: CARLSBAD PLAN CHECK#.: CBC2020-0244 PROJECT ADDRESS: 2550 EL CAMINO REAL SET I PROJECT NAME: RE PAINTING Bank of America c/4PPLICANT I JURIS. [g] The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's BUILDINGS codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: [g] EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted:1 {1 {2f) (byG{(//) Email: Mail Telephone 0 REMARKS: By: Bert Domingo EsGil Fax In Person Enclosures: 6/25/2020 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 CARLSBAD CBC2020-0244 7/07/2020 CARLSBAD CBC2020-0244 7/07/2020 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: CARLSBAD PREPARED BY: Bert Domingo BUILDING ADDRESS: 2550 EL CAMINO REAL BUILDING OCCUPANCY: B BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code CB By Ordinance -~-97 -u;--Bui1d1;··Pe~~~-Fee -----.;-i 9 C g 1997 use Plan Check Fee -- Type of Review: D Complete Review PLAN CHECK#.: CBC2020-0244 DATE: 7/07/2020 Reg. VALUE ($) Mod. O Structural Only I D Repetitive Fee -~ Repeats 0 Other 0 Hourly EsGil Fee 21 Hrs.@• ~====$=1 o=s=.o:o $210.001 " Based on hourly rate Comments: In addition to the above fee, an additional fee of$ is due ( hour@ $ /hr.) for the CalGreen review. Sheet 1 of 1 ~ CITY OF CARLSBAD 07-27-20 -Planning Dept Response PLANNING DIVISION BUILDING PLAN CHECK REVIEW CHECKLIST P-28 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.1rnv DATE: 7 /2/20 PROJECT NAME: PROJECT ID: APN: 1670305000 PLAN CHECK NO: CBC2020-0244 SET#: 1 ADDRESS: 2550 EL CAMINO REAL 0 This plan check review is complete and has been APPROVED by the PLANNING Division. By: SARAH CLUFF A Final Inspection by the PLANNING Division is required D Yes □ No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. ~ This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: MEIYEEYAM@SBCGLOBAL.NET For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 760-602-2750 760-602-4665 □ Hector Salgado □ 760-602-4624 H~~Qr .Salgado@cartsbad~,gQv □ Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov ~ Sarah Cluff 760-602-4619 Sarnb,Cluff@cadsba!!ca,@i ~ • ~ CITY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK REVIEW CHECKLIST P-28 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.,wv REVIEW#: 1 2 3 1:8] □ □ 1:8] □ □ 1:8] □ □ Plan Check No. CBC2020-0244 Address 2550 EL CAMINO REAL Date 7/2/20 Review# 1 Planner SARAH CLUFF Phone (760) 602-4619 APN: 1670305000 Type of Project & Use: EXTERIOR IMPROVEMENTS Net Project Density: DU/AC Zoning: SP 146/C-L General Plan:!: Facilities Management Zone: 2 CFO (in/out) #_Date of participation: __ Remaining net dev acres: __ (For non-residential development: Type of land use created by this permit: __ ) Legend: [gl Item Complete D Item Incomplete -Needs your action Environmental Review Required: YES O NO O TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES O NO 1:8] TYPE LANDSCAPE MODIFICATIONS ARE DOCUMENTED AT 440 SF PLUS 6 PALM TREES BEING REMOVED, UNDER THE 2,500 SF THRESHOLD FOR REQUIRING A NEW LANDSCAPE PLANCHECK. APPROVAURESO.NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: __ Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES O NO _l:8l. CA Coastal Commission Authority? YES O NO 0 If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Habitat Management Plan Data Entry Completed? YES O NO 0 If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Energov lnclusionary Housing Fee required: YES D NO D (Effective date of lnclusionary Housing Ordinance -May 21 , 1993.) Data Entry Completed? YES O NO 0 For construction of inclusionary units, email notification provided to HNS?: YES D NOD Site Plan: □□□ [81 □ □ (Email Susan Steinkemp in HNS with project number and contact info) Housing Tracking Form (form P-20) completed: YES O NO O NIA ~ PLEASE SEE REQUIRED CORRECTIONS IN ADDITIONAL COMMENTS BELOW. City Council Policy 44 -Neighborhood Architectural Design Guidelines 1. Applicability: YES O NO 0 2. Project complies: YES O NOD Zoning: 1. Setbacks: PER A00.00, EXTERIOR FINISH IMPROVEMENTS, NO ADDITIONAL AREA OR HEIGHT PROPOSED. Front: Interior Side: Street Side: Rear: Top of slope: Required __ Shown __ Required __ Shown __ Required __ Shown __ Required __ Shown __ Required __ Shown __ 2. Screening of Equipment: Required NO Shown __ 3. Parking: TOTAL BUILDING SQ. FT.= Office: Spaces Required __ Shown __ Manufacturing: Spaces Required __ Shown __ Warehouse: Spaces Required __ Shown __ 4. Outdoor Employee eating area: Square Footage Required __ Shown __ Response: The Palms being removed are NOT part of the Commercial Center's required parking lot trees. 0 0 0 Additional Comments 1. PLEASE DECLARE IF THE PALMS BEING REMOVED ARE OR ARE NOT PART OF THE COMMERCIAL CENTER'S REQUIRED PARKING LOT TREES. IF SO. DECLARE LOCATION OF THESE 6 TREES REQUIRED REPLACEMENT. 2. SIGNAGE CANNOT BE PROCESSED THROUGH THIS TENANT IMPROVEMENT PERMIT. Response: Noted. A. PLEASE REACH OUT TO THE PLANNING DIVISION AT PLANNING@CARLSBADCA.GOV TO ARRANGE SUBMITTAL FOR REVIEW OF A SIGN PERMIT USING THE P-11 APPLICATION ATTACHED AND ALSO AVAILABLE ON OUR CITY WEBSITE.Response: Planning Sign Application has been submitted. B. BUILDING ALSO HAS SEPARATE SIGNAGE APPLICATIONS REQUIRED TO PROCESS THE SIGN PERMITS FOLLOWING PLANNING'$ APPROVAL, Response: Noted. Once we have the signage approval from Planning , we will apply a P-28 separate sign permit Page 3 of 4 01111 with Bldg. REACH OUT TO THEIR DIVISION AT BUILDING@CARLSBADCA.GOV TO INQUIRE ABOUT THEIR PROCESS. B. ALL MENTION OF SIGNAGE MUST BE REMOVED FROM THE PLAN SHEETS TO BE GRANTED PLANNING'S APPROVAL. i. ALL REFERENCES TO SIGNAGE ON SHEETS INCLUDING, BUT Response: All signage NOT LIMITED TO, ARCHITECTURAL AND LANDSCAPE SHEET NOTES references have been removed MUST BE REMOVED: from the Bldg plans. ii. ALL IMAGES DEPICTING SIGNAGE REPLACEMENT ON SHEETS INCLUDING, BUT NOT LIMITED TO, ARCHITECTURAL AND LANDSCAPE SHEETS MUST BE REMOVED FROM THE PLANS: iii. ALL MENTION OF SIGNAGE IN ADDITIONAL 11x 17 ATTACHED SHEETS IS TO BE REMOVED: iv. SHEET A00.00 MUST REMOVE REFERENCE TO SIGNAGE SHEETS 1-17, EVEN THOUGH THEY WERE NOT INCLUDED IN THIS SUBMITTAL: AND v. PLEASE DO A THOROUGH WORD SEARCH FOR THE TERM "SIGN" TO ENSURE EVERY MENTION OF SIGN REPLACEMENT HAS BEEN REMOVED FROM ALL PLAN SHEETS IN ORDER TO BE GRANTED PLANNING APPROVAL. OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE P-28 Page 4 of 4 07/11 • .. ,I. ~ SAN DIEGO REGIONAL OFFICE USE ONLY HAZARDOUS MATERIALS RECORD ID# . PLAN CHECK# •,o;o .. G~ QUESTIONNAIRE BP DATE I I Business Name Business Contact Telephone# Bank of America Tim Beasley 925.348.1995 Project Address City Stale Zip Code APN# 2550 El Camino Real Carlsbad CA 92008 Malling Address City Stale Zip Code Plan File# Project Contact Applicant E-mail Telephone# Judy Yam meiyeeyam@sbcglobal.net 626.675.9882 . . The following questions represent the fac1hty's activities, NOT the specific proJeet description . PART I: FIRE DEPARTMENT -HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: (not required for projects within the City of San '2!.!sl2l: Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: Facility's Square Footage (including proposed project): 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reaclives 13. Corrosives 2. Compressed Gases 6. Oxidizers 10. Cryogenics 14. Other Health Hazards 3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 15. None of These. 4. Flammable Solids 8. Unstable Reaclives 12. Radioactives PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEAL TH -HAZARDOUS MATERIALS DIVISION fHMDI: If the answer to any of the questions Is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Avenue, Suite 110, San Diego, CA 92123. Call (858) 505-6700 prior lo the Issuance of a building permit. FEES ARE REQUIRED Project Completion Date: Expected Dale of Occupancy: 0 CalARP Exempt I 1. 2. 3. 4. 5. 6. 7. 8. YES NO (for new construction or remodeling projects) Is your business listed on the reverse side of this form? (check all that apply). D 0 D 0 D 0 Will your business dispose of Hazardous Substances or Medical Waste in any amount? Will your business store or handle Hazardous Substances In quantities greater than or equal to 55 gallons, 500 pounds and/or 200 cubic feet? D D D D D 0 Will your business store or handle carcinogens/reproductive toxins in any quantity? 0 Will your business use an existing or Install an underground storage tank? 0 Will your business store or handle Regulated Substances (CalARP)? 0 Will your business use or install a Hazardous Waste Tank System (Tille 22, Article 10)? 0 Wttl your business store petroleum In tanks or containers al your facility with a total facility storage capacity equal to or realer than 1 320 allons? California's Abov round Petroleum Stora e Act . Date Initials 0 CalARP Required I Date lnltlals 0 CalARP Complete I Date lnltlals PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT fAPCDI: Any YES• answer requires a stamp from APCD 10124 Old Grove Road, San Diego, CA 92131 apcdcomp@sdcounty.ca.gov (858) 586-2650). [•No stamp required if Q1 Yes fill2 Q3 Yes~ 04-06 No]. The following questions are intended lo identify the majority of air pollution issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive requirements contact APCD. Residences are typically exempt, except • those with more than one building• on the property; single buildings with more than four dwelling units; lownhomes; condos; mixed-commercial use; deliberate bums; residences forming part of a larger project. [•Excludes garages & small outbuildings.] 1. 2. 3. YES NO D 0 D 0 D 0 Will the project disturb 160 square feel or more of existing building materials? Will any load supporting structural members be removed? Notification may be required 10 working days prior to commencing demolition. (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance Technician? 4. D 0 (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification may be required 10 working days prior lo commencing asbestos removal. 0 Wffl the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCD factsheet (www.sdapcd.org/infotracts/permils.pdQ for typical equipment requiring an APCO permit. 5. 6. D D 0 (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be localed within 1,000 feel of a school bounda Briefly describe business activities: Briefly describe proposed project: Existing Bank of America Existing Bank of America I declare under penalty of perjury that to the best of my knowledge and belief t 06 / 16 120 Name of Owner or Authorized Agent Date FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: _______________________________ _ BY· DATE· I I &XliMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR IUILDINO PERMIT IUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMO• APCD COUNTY-HMO APCO COUNTY-HMO APCD ~it 1\)l\i J\) "0 ' , r \( l C\ \-. ~)J \ .. •A stamp In this box only exempts businesses from completing or updating a Hazardous Materials Business Plan. other permitting requirements may still apply. HM-9171 (08/15) County of San Diego -DEH -Hazardous Materials Division 4Ji 't 1\)1\) J~ate:'06-17-20 ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com C\ Business Name:_B_a_n_k_o_f_A_m_e_ri_ca ___________ _ B' street Address: 2550 El Camino Real, Carlsbad, CA 92008 Emall Address: meiyeeyam@sbcglobal.net PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) I ✓ I Check all below that are present at your facility: o Acid Cleaning o Assembly o Automotive Repair o Battery Manufacturing o Biofuel Manufacturing o Biotech Laboratory o Bulk Chemical Storage o Car Wash o Chemical Manufacturing o Chemical Purification o Dental Offices • Dental Schools • Dental Clinics o Dry Cleaning o Electrical Component Manufacturing o Fertilizer Manufacturing o Film/X-ray Processing o Food Processing o Glass Manufacturing o Industrial Laundry o Ink Manufacturing o Laboratory o Machining/Milling o Membrane manufacturing (i.e. water filter membranes) o Metal Casting/Forming o Metal Fabrication o Metal Finishing • Electroplating • Electroless Plating • Anodizing • Coating (i.e. phosphating) • Chemical Etching/Milling • Printed Circuit Board Manufacturing o Metal Powders Forming o Nutritional Supplement/Vitamin Manufacturing o Painting/Finishing o Paint Manufacturing o Personal Care Products Manufacturing o Pesticide Manufacturing/ Packaging o Pharmaceutical Manufacturing (including precursors) o Porcelain Enameling o Power Generation o Print Shop o Research and Development o Rubber Manufacturing o Semiconductor Manufacturing o Soap/Detergent Manufacturing o Waste Treatment/Storage New Business? Yes0No(£1 SIC Code(s) if known: ______ Date operation began/will begin: ______ _ Tenant Improvement? Yes0Nc0 If yes, briefly describe improvement: _________________ _ (E) bank exterior finishes, and landscape improvement Description of operations generating wastewater (discharged to sewer, hauled or evaporated): __________ _ NIA -(E) Bank Estimated volume of industrial wastewater to be discharged (gal/ day): _N_I_A_-_(_E_)_B_a_n_k ___________ _ List hazardous wastes generated (type/volume):_N_/_A_-___ (E ___ ) _B_a_n_k __________________ _ Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? YesO Date: ____ No[£! Page 1 of2 ENCINA WASTEWATER AUTHORITY INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY 6200 Avenida Encinas, Carlsbad, CA 92011 Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinaJpa.com The commercial enterprises listed below are a partial listing of businesses that are exempt from industrial wastewater discharge permitting under normal operating conditions. They are exempt because (a) they discharge no process wastewater (i.e., they only discharge sanitary wastewater with no pollutants exceeding any local limits), and (b) they have no potential to negatively impact the EWPCF or other wastewater treatment plants in the ESS. Any questions regarding exemptions should be referred to EWA Source Control staff. o Automobile Detallers o Barber/Beauty Shops o Business/Sales Offices o Cleaning Services o Carpet/Upholstery o Childcare Facilities o Churches o Community Centers o Consulting Services o Contractors o Counseling Services o Educational Services (no auto repair/film developing) )( Financial Institutions/Services o Fitness Centers o Gas Stations (no car wash/auto repair) o Grocery Stores (no film developing) o Residential based Businesses CERTIFICATION STATEMENT o Hotels/Motels (no laundry) o Laundromats o Libraries o Medical Offices (no x-ray developing) o Mortuaries o Museums o Nail Salons o Nursing Homes o Office Buildings (no process flow) o Optical Services o Pest Control Services (no pesticide repackaging for sale) o Pet Boarding/Grooming Facilities o Postal Services (no car wash/auto repair) o Public Storage Facilities o Restaurants/Bars o Retail/Wholesale Stores (no auto repair/film developing) o Theaters (Movie/Live) I certify that the information above is true and correct to the best of my knowledge. cJIV' Print Name: J,.171 'f,h1 Signature: Facility Contact: __________ _ Title:. ______________ _ ENCINA WASTEWATER AUTHORITY 6200 AVENI DA ENCINAS, CARLSBAD, CA Phone: 760-438-3941 Fax: 760-476-9852 SourceControl@encinajpa.com Page 2 of 2 C cicyof Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. The completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy-related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. NOTE: The following type of pennits are not required to fill out this fonn ❖ Patio I ❖ Decks I ❖ PME (w/o panel upgrade) I ❖ Pool ,. If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. ,. Details on CAP ordinance requirements are available on the city's website. ,. A CAP Building Plan template (form B-55) shall be added to the title page all building plans. This template shall be completed to demonstrate project compliance with the CAP ordinances. Refer to the building application webpage and download the latest form. Project Name/Building Pennit No.: Bank of America Property Address/APN: 2550 El Camino Real ApplicantName/Co.: Judy Yam/ MJY Group, Inc BP No.: C f?(_,1[/2.0-02-4'{ Applicant Address: 392 NB. Le May Court, Orange, CA 92867 Contact Phone: 626.675.9882 Contact Email: meiyeeyam@sbcglobal.net Contact information of person completing this checklist (if different than above): Name: Company name/address: Applicant Signature: Judy Yam B-50 Contact Phone: Contact Email: ~ Date: 06-17-20 Page 1 of 6 Revised 08/19 City of Carlsbad Climate Action Plan Consistency Checklist Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. For alterations and additions to existing buildings, attach Building Permit Valuation worksheet. Building Permit Valuation (BPV} from worksheet: $_9_o,_ooo ____ _ 0 Residential A high-rise residential building is 4 or more stories, including a Low-rise High-rise mixed-use building in which at least 20% of its conditioned floor area is residential use □ New construction 3B,4A I '"· 2B, □ Additions and alterations: □ BPV < $60,000 NIA N/A All residential additions and alterations □ BPV ;i,; $60,000 1A,4A 4A 1-2 family dwellings and townhouses with attached garages □ Electrical service panel upgrade only only •Multi-family dwellings only where interior finishes are removed □ BPV c?: $200,000 1A, 4A• 18, 4A• and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed 0 Nonresidential □ New construction 1B, 2B, 3B, 4B and 5 I □ Alterations: □ BPV c?: $200,000 or additions c?: 1,000 1B,5 square feet □ BPV c?: $1,000,000 18, 2B, 5 Building alterations of c?: 75% existing gross floor area □ c?: 2,000 sq. ft. new roof addition 2B, 5 1 B also applies if BPV c?: $200,000 . Energy Efflclency Please refer to Carlsbad Municipal Code (CMC} sections 1821.155 and 18.30.190, and the California Green Building Standards Code (CAL.Green) for more information vAlen completing this section. A. D Residential addition or alteration i? $60,000 building pennit valuation. See CMC section 18.30.190. Year Built Single-family Requirements D Before 1978 Select one: D Duct sealing D Attic insulation □Cool roof D 1978 and later Select one: D Lighting package D Water heating Package D Between 1978 and 1991 D 1992 and later D NIA, _________ _ □ Exception: Home energy score ;?: 7 (attach certification) Multi-family Requirements D Altic insulation Select one: D Duct sealina D Attic insulation □Cool roof Select one: D Lighting package D water heating package B. 0 Nonresidential" new construction or alterations i? $200,000 bulldlng pennlt valuation, or additions i? 1,000 square feet 0 NIA Updated 8/15/2019 2 ' . City of Carlsbad Climate Action Plan Consistency Checklist See CMC 18.21.155 and CALGreen Appendix AS, Division AS.2 -Energy Efficiency. A5.2O3.1.1 Choose one: □ .1 Outdoor lighting □ 2 Warehouse dock seal doors □ .3 Restaurant service water heating (comply vmh Celifomia Energy Code section 140.5, as amended) 0 NIA ________ _ □ .4 Daylight design PAFs □ .5 Exhaust air heat re<.<:Nery A52O3.1.2.1 Choose one as applicable: □ .95 Energy budget □ .90 Energy budget 0 NIA A5.211.1 .. □ On-site renewable energy 0 NIA A5211.3 .. □ Green power (rf offered by local utility provider, 50% rnnirrum renewable sources) 0 NIA A5212.1 □ Elevators and escalators 0 NIA A5213.1 □ Steel frami'lg 0 NIA • Includes hotels/motels and high-rise residential buildings .. For alterations~ $1,000,000 BPV and affecting > 75% existing gross floor area, or alterations that add 2,000 square i!et of new roof addition: comply with CMC 18.30.130 instead. 2. Photovoltaic Systems A. D Residential new construction (for low-rise residential building permit appllcatlons submitted after 1/1/20). Refer to 2019 California Energy Code section 150.1(c)14 for requirements. Notes: 1) High-rise residential buildings are subject to nonresidential photovoltaic requirement (2B below) Instead. 2) If project Includes Installation of an electric heat pump water heater pursuant to CMC 18.30.150(B) (high-rise residentlaQ or 18.30.170(8) (low-rise resldentlal), Increase syst&m size by .3kWdc If PV offset option Is selected. Floor Plan ID (use additional CFA fd.u. Calculated kW:lc* sheets if necessary) Total System Size: kW:lc = (CFAx.572) / 1,000 + (1.15 x fd.u.) *Forrrula calculation where CFA = conditional floor area, fdu = number of dwellings per plan type If proposed system size is less than calculated size, please explain. Exception □ □ □ □ kW:lc B. 0 Nonresidential new construction or alterations ~1,000,000 BPV and affecting ~75% existing floor area, or addition that Increases roof area by ~000 square feet Please refer to CMC section 18.30.130 when completing this section. Note: This section also applies to high-rise residential and hotel/motel buildings. Choose one of the following methods: □ Gross Floor Area (GFA) Method GFA □If< 10,000s.f. Enter: 5 kVVdc Min. System Size: □ If c?: 10,000s.f. calculate: 15 kWdc x (GFA/10,000) .. kVVdc ""Round building size factor to nearest tenth, and round system size to nearest whole number. □Time-Dependent Valuation Method Updated 8/15/2019 3 . ' City of Carlsbad Climate Action Plan Consistency Checklist Annual TDV Energy use:... _____ x .80= Min. system size: _____ kVVdc ... Attach calculation documentation using modeling software approved by the California Energy Commission. 3. Water Heating A. D Resldentlal and hotel/motel new construction Please refer to CMC sections 18.30.150 and 18.30.170 when completing this section. D For systems serving lndlvldual dwelling units choose one: D Heat pump water heater AND Compact hot water distribution AND Drain water heat recovery (low-rise residential only} D Heat pump water heater AND PV system .3 kWdc larger than required in CMC section 18.30.130 (high rise residential hoteVmotel} or CA Energy Code section 150.1 (c} 14 (low-rise residential) D Heat pump water heater meeting NEEA Advanced Water Heating Specification Tier 3 or higher D Solar water heating system that is either .60 solar savings fraction or 40 s.f. solar collectors D Exception: D For systems serving multiple dwelling units, install a central water-heating system with all of the following: D Gas or propane water heating system D Recirculation system per CMC 18.30.150(8) (high-rise residential, hoteVmotel) or CMC 18.30.170(8) (low- rise residential) D Solar water heating system that is either: D .20 solar savings fraction D .15 solar savings fraction, plus drain water heat recovery D Exception: 8. D Nonresldentlal new construction Please refer to Carlsbad Ordinance CMC section 18.30.150 when completing this section. D Water heating system derives at least 40% of its energy from one of the following (attach documentation}: D Solar-thermal D Photovoltaics D Recovered energy □Water heating system is (choose one): D Heat pump water heater □ Electric resistance water heater(s} □Solar water heating system with .40 solar savings fraction D Exception: Updated 8/15/2019 4 City of Carlsbad Climate Action Plan Consistency Checklist 4. Electric Vehicle Charging A. D Residential New construction and major alterations* Please refer to Cartsbad Ordinance CMC section 18.21.140 when com letin this section. One and two-family residential dwelling or townhouse with attached garage: Done EVSE Ready parking space required D Exception : □Multi-family residential: D Exception: Calailations: Total EVSE spaces= .10 x Total parking (rounded up to nearest whole numbery EVSE Installed = Total EVSE Spaces x .50 (rounded up to nearest whole numbery EVSE other= Total EVSE spaces-EVSE Installed (EVSE other may be "Capable," "Ready" or "Installed.") Total *Major allerations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building perm~ valuation ~ $60,000 or indude an electrical service panel upgrade; (2) for multifamily dwelfings (three units or more wthout attached garages), alterations have a buiding pennit valuation ~ $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, eledrical, and/or plurmng systems are proposed. B D Nonresidential new construction (includes hotels.lmotels) D Exception · Total Parking Spaces EVSE Spaces Proposed Capable I Ready I Installed I Total 10 2 I 5 I 1 I 8 Calculation· Refer to the table below: Total Number of Parkill!l Soaces orovided Number of reauired EV Soaces Nun"ber of reauired EVSE Installed Soaces 0-9 1 1 10-25 2 1 L 26-50 4 2 n 51-75 6 3 D 76-100 9 5 n 101-150 12 6 n 151-200 17 9 □ 201 and over 1 0 cercent of total 50 cercent of Reauired EV Soaces Updated 8/15/2019 5 City of Carlsbad Climate Action Plan Consistency Checklist 5. □ Transportation Demand Management (TOM): Nonnsldentlal ONLY An approved Transportation Demand Management (TOM) Plan is required for all nonresidential projects that meet a threshold of employee-generated ADT. City staff wiU use the table below based on your submitted plans to determne v.ilether or nor your pemit requires a TOM plan. If TOM is applicable to your permit, staff will contact the applicant to develop a site-specific TOM plan based on the permit details. Ackn0Yt1edgment: Employee ADT Estimation for Various Commercial Uses Use Emp ADTfor first 1,000 s.f. Emp ADTI 1000 s.f.1 Office (all)2 20 Restaurant 11 Retaib 8 Industrial 4 Manufacturing 4 Warehousin 4 1 Unless otherwise noted, rates estimated from /TE Trip Generation Manual, 1(1hEdition 13 11 4.5 3.5 3 1 2 For all office uses, use SANDAG rate of 20 ADT/1,000 sf to calculate employee ADT 3 Retail uses include shopping center, variety store, supermarket, gyms, pharmacy, etc. Other commercial uses may be subject to special consideration Sample calculations: Office: 20,450 sf 1. 20,450 sf / 1000 x 20 = 409 Employee ADT Retail: 9,334 sf 1. First 1,000 sf= 8 ADT 2. 9,334 sf-1,000 sf= 8,334 sf 3. 8,334 sf/ 1,000 x 4.5 + 8 = 46 Em lo ee ADT I acknowledge that the plans submitted may be subject to the City of Carlsbad's Transportation Demand Management Ordinance. I agree to be contacted should my permit require a TOM plan and understand that an approved TOM plan is a condition of permit issuance. ApplicantSignature: Judy Yam oate: 06-16-20 Person other th-, Applicant to be contacted for TDM compliance (If applicable): Name (Printed): _________________ _ Phone Number: ____ _ Email Address: _________________ _ Updated 8/15/2019 6