Loading...
HomeMy WebLinkAbout2550 GATEWAY RD; ; CB121117; Permit08-14-2012 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: Building Inspection Request Line (760) 602-2725 CB121117 Job Address: Permity Type: Parcel No: Valuation: Occupancy Group: Project Title: 2550 GATEWAY RD CBAD Tl Sub Type: INDUST 2132611505 Lot#: 0 $129,463.11 Construction Type: 5A Reference # AUDACITY GROUP: 3483 SF SHELL TO OFF. Status: ISSUED Applied: 06/14/2012 Entered By: JMA Plan Approved: 08/14/2012 Issued: 08/14/2012 Inspect Area Plan Ctieck #: Applicant: KIM STONE WARE MALCOMB 6363 GREENWICH DR., STE. SAN DIEGO CA 92122 858-638-7277 175 Owner: OCEAN COLLECTION LLC C/O PETERSON&PRICE APC 655 W BROADWAY #1600 SAN DIEGO CA 92101 Building Permit $813.22 Meter Size Add'l Building Permit Fee $0.00 Add'l Reel. Water Con. Fee $0.00 Plan Check $569.25 Meter Fee $0.00 Add'l Building Permit Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $27.19 PFF (3105540) $2,356.23 Park Fee $0.00 PFF (4305540) $0.00 LFM Fee $0.00 License Tax (3104193) $0.00 Bridge Fee $0.00 License Tax (4304193) $0.00 BTD #2 Fee $0.00 Traffic Impact Fee (3105541) $4,929.00 BTD #3 Fee $0.00 Traffic Impact Fee (4305541) $0.00 Renewal Fee $0.00 PLUMBING TOTAL $0.00 Add'l Renewal Fee $0.00 ELECTRICAL TOTAL $0.00 Other Building Fee $0.00 MECHANICAL TOTAL $0.00 Pot. Water Con. Fee $0.00 Master Drainage Fee $0.00 Meter Size Sewer Fee $2,441.56 Add'l Pot. Water Con. Fee $0.00 Redev Parking Fee $0.00 Reel. Water Con. Fee $0.00 Additional Fees $0.00 Green BIdg Stands (SB1473) Fee $4.00 HMP Fee ?? Fire Expedidted Plan Review $227.50 Green BIdg Standards Plan Chk ?? TOTAL PERMIT FEES $11,367.95 Total Fees: $11,367.95 Total Payments To Date: $11,367.95 Balance Due: $0.00 Inspector: FINAL APPROVAL Date: f-^^V^ Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively refened to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth In Govemment Code Section 66020(a), and file the protest and any other required Information with the City Manager for processing In accordance with Carisbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connectron fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have oneviouslv been given a NOTICE similar to this, or as to which the statute of limitations has previously othenvise expired. CITY OF CARLSBAD Building Permit Application 760-602-2717/2718/2719 Fax 760-602-8558 vwvw.carlsbadca.gov Plan Check No. 1 2. i | [1 Est. Value Plan Ck. Deposit Date (^((^[^-^ SWPPP JOB ADDRESS SUITE#/SPACE#/UriiT» Xl3- 2^,1-OS OT/PROJECT# # BEDROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE OCC. GRO DESCRiPTiON OF WORK: include Square Feet of Affected Area(s) EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE YESr~T# N AIR CONDITIONING YES I |NO| I FIRE SPRINKLERS YES I |NO| I APP.^NT^^^...^^t^^^^^ ^ APPLICANT NAME (Secondary Co ADDRESS ADDRESS CITY VO /I , ~ STATE /. y ZIP ^ , PHONE/'^ 1 / —^ L/ ^|FAX „ ITT , _ „ -^54^2) ^/(^^^ ..^^^ PHONE _ ^ _ 3,_ . . , , , I FAX NERNA.E /^^en./7^e^ EMAIL EMAIL PROPERTY OWNER NAME CONTRACTOR BUS. NAME / 7 7""^ STATE (/ ZIP - ADDRESS ADDRESS CITY CITY PHONE ARCH/DESIGNER NAME & ADDRES f / blAlt LIU. # ^ ^ — (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, phor to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with SecUon 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violaUon of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). WORKERS'COMPENSATIOMj Workers' Compensation Declaration: / herefiy affirm under penalty of perjury one ofthe foiiowing declarations: LJ I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which ttiis permit is issued. I have and will maintain wodters' compensation, as required by Section 3700 of the Latwr Code, for the performance of the work for which this pennit is issued. My workers' compensation insurance canier and policy numbei ate: Insurance CoS-.'^Tt'-^g-^cc^ Policy No Expiration Date „ idred dollars I pijs section need not be completed if the permit is for one tiundred dollars ($100) or less, I I Certificate of Exemption: I certify that in the perfonnance of the work for which this permit is issued, I shall not employ any person in any manner so as to tiecome subject to the Workers' Compensation Laws of Califomia, WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, djmages as provided for in S^myi 3706 of the Labor code, interest and attorney's fees. yfif CONTRACTOR SIGNATURE ^^udjLe/CC^ /Y^-t-^7^U2-.A_^ • AGENT DATE " ~^/^ OWNER-BUILDET! DECLARATION^^ / hereby affirm that I am exempt from Contractor's Ucense Law for the following reason: I I I, as owner of Ihe property or my employees with wages as their sole compensation, will do the work and the stmcture is not intended or offered for sale (Sec, 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have Ihe burden of proving that he did not build or improve for the purpose of sale), I I I, as owner of the property, am exclusively contracting with licensed contractors to constmct the project (Sec, 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I I I am exempt under Section _ ^Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for constmction of the proposed property improvement, ^]Yes I iNo 2.1 (have / have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number): 5,1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of wort(): PROPERTY OWNER SIGNATURE QAGENT DATE COMPLETE THIS SECTION FOR N O N - R E S I D E N T I A L BUILDING P E R IH I T S ONLY Is the applicant or future building occupant required to submit a business plap, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes No Is the applicant or future building occupant required to obtain a permit ffwi the air pollution control district or air quality management district? Yes Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes ^''~+Jo IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the perfonnance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address APPLICANT CERTIFICATIO I certity that I have lead the applicaton and state that the above infonnation is conect and that the Infonnation on the plans is accu I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned properly for inspectbn purposes, I ALSO AGREE TO SAVE, INDEIMNIPr" AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT, OSHA: An OSHA pemiit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height, EXPIRATION: Every pemiit issued by the Building Oflicial under the provisions rfthis Code shall expire by limitation and become null and void if the building orwor1( authorized by such pemnit is not commenced within 180 days from the date of such pennit or if the buikJing or work auttjoreedijjrsoch pemiit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Sectfon 106,4,4 Unifomi Building Code). APPLICANT'S SIGNATURE DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERIVIIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. CERTIFICATE OF OCCUPANCY (Commercial Projects On Fax (760) 602-8560, Email www.buildinaiScarisbadca.aov or l^ail the completed form to City of Carisbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. C0#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS Carlsbad CA PHONE EMAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPnONS PICK UP: CONTACT (Usted above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) MAIL TO: CONTACT (Listed above) CONTRACTOR (On Pg. 1) IWAIL / FAX TO OTHER: OCCUPANT (Usted above) ASSOCIATED CB#- NO CHANGE IN USE / NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION APPLICANT'S SIGNATURE DATE Inspection List PermlW: CB121117 Type: Tl INDUST AUDACITY GROUP: SHELL TO OFF. 3483 SF pate Inspection Item Inspector Act Comments 09/26/2012 89 Final Combo - Rl 09/26/2012 89 Final Combo PD AP 08/20/2012 17 Interior Latti/Drywall PD AP 08/15/2012 84 Rough Combo PD AP Wednesday, September 26.2012 Page 1 of 1 ^ CITY OF CARLSBAD Building Division INSPECTION RECORD INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION FOR BUILPING INSPECTION CALL: 760-602-2725 DATE: PliH CZ CB121117 2550 GATEWAY RD AUDACITY GROUP: SHELL TO OFF. 3483 SF Tl INDUST Lot#: KIM STONE KL wORD COPY THE FOLLOWING (CHECKEDI APPROVALS ARE REOUIRED PRIOR TO REQUESTING A FINAL BUILDING INSPECTION If you have any questions please call the applicable divisions at the phone numbers provided below. After all required approvals are signed off- fax to 760-602-8560, email to bidqinspectionsgjcarlsbadca.qov or bnng in a COPY of this card to: 1635 Faraday Ave., Carlsbad, CA 92008. Building inspectors can be reached at 760-602-2700 between 7:30 am - 8:00 am the day of your inspection. Required for Final If Checlced Date Inspector Notes Q Planning / Landscape 760-944-8463 • CM&I (Engineering Inspections) 760438-3891 Fire Prevention 760-602-4660 • Land Dev. Engineering 760-438-2740 Type of Inspection Date BUILDING FOUNDATION Inspector Type of Inspection ELECTRICAL • ELECTRIC UNDERGROUND • UI^R Date Inspector REINFORCED STEEL ROUGH ELECTRIC WALLS MASONRY ROUGH ELECTRIC CEILING • GROUT • WALL DRAINS • ELECTRIC SERVICE • TEMPORARY TILT PANELS • BONDING • POOL POUR STRIPS PHOTOVOLTAIC COLUMN FOOTINGS FINAL SUBFRAME • FLOOR • CEILING ROOF SHEATHING MECHANICAL UNDERGROUND DUCTS & PIPING EXT. SHEAR PANELS • DUCT & PLEM • REF. PIPING FRAME HEAT-AIR COND. SYSTEMS INSULATION VENTIALTING SYSTEMS EXTERIOR LATH FINAL INTERIOR LATH & DRYWALL FINAL OCCUPANCY PLUMBING Date • SEWER & BL/CO • PL/CO UNDERGROUND -ETWASTE • WATER Inspector Date A/S UNDERGROUND VISUAL Inspector A/S UNDERGROUND HYDRO TOP OUT SlfASTE DiffATER A/S UNDERGROUND FLUSH TUB & SHOWER PAN A/S OVERHEAD VISUAL • GAS TEST •GAS PIPING A/S OVERHEAD HYDROSTATIC • WATER HEATER • SOLAR WATER A/S HNAL FINAL F/A ROUGH-IN STORM WATER F/A FINAL 600 - PRE-CONSTRUCTION MEETING FIXED EXTINGUISHING SYSTEM ROUGH-IN 603 - FOLLOW UP FIXED EXTING SYSTEM HYDROSTATIC TEST 60S-NOTICE TO CLEAN FIXED EXTINGUISHING SYSTEM FINAL 607-WRIHEN WARNING MEDICAL GAS PRESSURE TEST 609-NOTICE OF VIOLATION MEDICAL GAS FINAL 610 - VERBAL WARNING FINAL FINAL RB/5/2012 EE BACK FOR SPECIAL NOTES EsGil Corporation In (Partnership with government for (BuiCding Safety DATE: 8/10/12 • APPLICANT •-lURIS. JURISDICTION: City of Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO.: 12-1117 SET: III PROJECT ADDRESS: 2550 Gateway Rd PROJECT NAME: Audacity - TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. 3 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified In the remarks below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. I I EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax in Person 3 REMARKS: Applicant to slip sheet revised sheet A6.2 to City held sets. _ By: Doug Moody Enclosures: ' v!_ EsGil Corporation • GA • EJ • PC 8/3/12 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In Partnership with government for (BuiCdtng Safety DATE: 7/27/12 • ^PELICANT JURISDICTION: City of Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO.: 12-1117 SET: II PROJECT ADDRESS: 2550 Gateway Rd PROJECT NAME: Audacity - TI l~] The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. 3 The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to fonward to the applicant contact person. 3 The applicant's copy of the check list has been sent to: Ware Malcomb /Kim Stone 6363 Greenwich Dr Suite 175, San Diego, CA 92122 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. 1X1 EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Kim Stone Telephone #: 858-638-7277 Date contacted:[1-7.1,2. (by: ^) Email: kstone@waremalcomb.com Fax #: 858-638-7506' ^ Mail-^ Telephone Fax In Person • REMARKS: By: Doug Moody Enclosures: EsGil Corporation • GA • EJ • PC 7/19/12 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858)560-1468 • Fax (858) 560-1576 City of Carlsbad 12-1117 7/27/12 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue. 1. Please revise the plans to show the glazed wall thickness consistent with the Table provided on sheet A6.2 and show the 10' high wall to be minimum %" tempered glazing . Section 107.2. Please revise the plans to be consistent. Note 5 on sheet A2.1 indicates Vs" tempered glazing, detail 4 on sheets A6.2 indicates Vii' tempered glazing and the elevation B on sheet A6.2 indicates VA" tempered glazing all for the same wall? 2. Provide the method of compliance as required by the energy building regulations (Title 24) for this tenant improvement: • Provide documentation of the original energy design with modifications (additions or alternations) as applicable for this tenant improvement. (If energy design was part of the "shell" permit) or • Provide a complete energy design as required for a new building. Please have the document author and principle designers sign the forms and imprint the required forms on the plans. Revise the plans to show the insulation required in the energy documents. 3. Please revise the plumbing plans to show the total aggregate vent area to be equal to the required sewer size per section 904.1 ofthe UPC. (A minimum of 7.06 square inches). The plans show a 4" pipe connected to 2-2" vent pipe this does not equal 7.06 inches of free air to the sewer. Please correct. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. City of Carlsbad 12-1117 7/27/12 Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes • No • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. EsGil Corporation In Partnership •with government for (Building Safety DATE: 6/25/12 O^AEEyCANT JURIS?, JURISDICTION: City of Carlsbad • PDWREVIEWER • FILE PLAN CHECK NO.: 12-1117 SET: I PROJECT ADDRESS: 2550 Gateway Rd PROJECT NAME: Audacity - TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ^ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list Is enclosed for the jurisdiction to fonward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Ware Malcomb /Kim Stone 6363 Greenwich Dr Suite 175, San Diego, CA 92122 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. 1X1 EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Kim Stone CV.M) Telephone #: 858-638-7277 Date contacted: «^ f it^l j 2.(by: ^) Email: kstone@waremalcomb.com Fax #: 858-638-7506 ^Mall .^telephone ^ Fax In Person • REMARKS: By: Doug Moody Enclosures: EsGil Corporation • GA • EJ • PC 6/14/12 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858)560-1468 • Fax (858) 560-1576 City of Carlsbad 6/25/12 12-1117 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 12-1117 OCCUPANCY: B TYPE OF CONSTRUCTION: VB ALLOWABLE FLOOR AREA: SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 6/14/12 DATE INITIAL PLAN REVIEW COMPLETED: 6/25/12 JURISDICTION: City of Carlsbad USE: Office ACTUAL AREA: 3483sf STORIES: 2 HEIGHT- OCCUPANT LOAD: 43 DATE PLANS RECEIVED BY ESGIL CORPORATION: 6/14/12 PLAN REVIEWER: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2010 CBC, which adopts the 2009 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2009 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed UP the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked UP list when vou submit the revised plans. City of Carlsbad 12-1117 6/25/12 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Please revise the plans to show the glazed wall thickness consistent with the Table provided on sheet A6.2 and show the 10' high wall to be minimum %" tempered glazing . Section 107.2. 2. Provide the method of compliance as required by the energy building regulations (Title 24) for this tenant improvement: • Provide documentation of the original energy design with modifications (additions or alternations) as applicable for this tenant improvement. (If energy design was part of the "shell" permit) or • Provide a complete energy design as required for a new building. 3. Please indicate on the plans the location of the electrical panel and detail the required working clearance. 4. Show on the plan that ground-fault circuit-interrupter protection complies with NEC Art. 210-8 All 125-volt, single-phase, 15- and 20- ampere receptacles installed at sinks shall be protected. 5. Please have the document author and the principle designer of the LTG-1 C form sign the imprinted document. 6. Please complete the LTG-1-C part 3 of 4 mandatory automatic controls portion ofthe LTG-1-C forms. 7. Please revise the plumbing plans to show the total aggregate vent area to be equal to the required sewer size per section 904.1 ofthe UPC. (A minimum of 7.06 square inches). 8. Where a pair of doors is utilized, at least one of the doors shall provide a clear, unobstructed opening width of 32 inches, per Section 1133B.2.3.1. City of Carlsbad 12-1117 6/25/12 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes • No • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. City of Carlsbad 12-1117 6/25/12 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 12-1117 PREPARED BY: Doug Moody DATE: 6/25/12 BUILDING ADDRESS: 2550 Gateway Rd BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VB BUILDING PORTION AREA ( Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Tl 3483 37.12 129,289 Air Conditioning Fire Sprinklers TOTAL VALUE 129,289 Jurisdiction Code Cb By Ordinance BIdg. Perml Fee by Ordhanoe Plan Check Fee by Ordinance Type of Review: I I Repetitive Fee ~ Repeats [7] Complete Review • Other |—I Hourly EsGil Fee • Structural Only Hr. @ * $813.22 $528.59 $455.40 Comments: Sheet 1 of 1 macvalue.doc ••• PLAN CHECK PLAN CHECK Community & Economic NJJ^ CITY OF REVIEW Development Department 1635 Faraday Avenue CARLSBAD TRANSMITTAL Carlsbad CA 92008 www.carlsbadca.gov DATE: 6/25/12 PROJECT NAME: BRESSI RANCH OCEAN COLLECTION (LOTS 17-18) PROJECT ID: PIP 06-11 PLAN CHECK NO: CB 12-1117 SET#: 1 ADDRESS: 2550 GATEWAY RD (BUILDING B) APN: 213-261-08-00 VALUATION: 129,763.11 AUDACITY TENANT IMPROVEMENT / This plan check review is complete and has been APPROVED by the Division. By: A Final Inspection by the CM&I Division is required ves / No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: kstone@waremaicomb.com Vou may a/so have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.gov Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.gov Greg Ryan 760-602-4663 Gregory.Ryan@carlsbadca.gov Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov / Linda Ontiveros • 760-602-2773 Linda.Ontiveros@carlsbadca.gov Cindy Wong 760-602-4662 Cynthia.Wong@carlsbadca.gov Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.gov Remarks: • THIS DOES NOT REFLECT ALL FEES INCURRED WITH THIS PERMIT, PLEASE CONTACT THE BUILDING DIVISION FOR A COMPLETE LISTING OF FEES* Fee Calculation Worksheet PC070003 LAND DEVELOPMENT ENGINEERING DIVISION ShelhCB 07-434 Prepared by: Linda Ontiveros Date: June 25,2012 GEO DATA: LFMZ: /B&T: Address: 2550 Gateway Rd (AUDACITY TENANT IMPROVEMENT) BIdg. Permit #: CB 12-1117 Fees Update by: Date: Fees Update by: Date: EDU CALCULATIONS: List types and square footages for all uses. Types of Use: OFFICE Types of Use: [SHELL CREDIT] Types of Use: Types of Use: Sq.Ft./Units 3,483 SF/1800 Sq.Ft./Units [3,483 SF/5000] Sq.Ft./Units Sq.Ft./Units EDU's: 1.94 EDU EDU's: [0.70] EDU's: TOTAL: 1.24 EDU's EDU's: ADT CALCULATIONS: List types and square footages for all uses. Sq.Ft./Units 20/1000 (3,483 SF) Sq.Ft./Units [5/1000(3483 SF)] Sq.Ft./Units Sq.Ft./Units Types of Use: OFFICE Types of Use: [SHELL CREDIT] Types of Use: Types of Use: FEES REQUIRED: Within CFD: / YES (no bridge & thoroughfare fee in District #1, reduces Traffic Impact Fee) NO ADTs ADTs ADTs ADTs 70 ADT [17] TOTAL: 53 ADT's X 1. PARK-IN-LIEU FEE: NW QUADRANT ADTS/UNITS; | X 2. TRAFFIC IMPACT FEE: ADTS/UNITS: 53 | X 3. BRIDGE & THOROUGHFARE FEE: ADTS/UNITS: 4. FACILITIES MANAGEMENT FEE ADTS/UNITS: 5. SEWER FEE EDU's 1.24 BENEFIT AREA: H EDU's 1.24 6. DRAINAGE FEES: ACRES: 7. POTABLE WATER FEES: UNITS CODE NE QUADRANT FEE/ADT: FEE/ADT: 93 DIST #1 FEE/ADT: ZONE: FEE/SQ.FT./UNIT: X FEE/EDU: 1.096 X PLDA: X FEE/EDU: 873 HIGH FEE/AC: SE QUADRANT |=$ =$ 4,929 DIST.#2 =$ =$ =$ 1,359.04 =$ 1,082.52 UM =$ ;W QUADRANT L DIST.#3 MED LOW CONN. FEE METER FEE SDCWA FEE TOTAL ;0^ CITY OF CARLSBAD STORM WATER COMPLIANCE ASSESSMENT B-24 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov am applying to the City of Carlsbad for the following type(s) of construction permit: ySL Building Permit • Right-of-Way Permit ^•^jpi^y project Is categorically EXEMPT from the requirement to prepare a storm water pollution prevention plan (SWPPP) because it only requires issuance of one or more of the following permit types: Electrical Fire Additional Fire Alarm Fixed Systems Mechanical Mobile Home Plumbing Patio/Deck Photo Voltaic Re-Roofing Sign Spa-Factory Sprinkler Water Discharge Project Storm Water Threat Assessment Criteria* No Threat Assessment Criteria My project qualifies as NO THREAT and is exempt from the requirement to prepare a storm water pollution prevention plan (SWPPP) because ~ me^ the 'no threaf assessment criteria on the City's Project Threat Assessment Wori(sheet fbr Detenninatkm of Constructton SWPPP Tier Level. My project does not meet any ofthe High, Moderate or Low Threat criteria described below. Tierl - Low Threat Assessment Criteria • My project does not meet any of the Significant or Moderate Threat criteria, Is not an exempt pemnit type (See list above) and the project meets one or more of the following criteria; • Results in some soil disturbance; and/or • Includes outdoor construction activities (such as saw cutting, equipment washing, material stockpiling, vehicle fueling, waste stockpiling). 7/er2 - Moderate Threat Assessment Criteria • My project does not meet any of the Significant Threat assessment Criteria described below and meets one or more of the following criteria: • Project requires a grading plan pursuant to the Carisbad Grading Ordinance (Chapter 15.16 of the Carisbad Municipal Code); or, • Project will result in 2,500 square feet or more of soils dlsturt)ance Including any associated constmction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas and pnDject meets one or more ofthe additional following criteria: • Located within 200 feet of an environmentally sensitive area or the Pacific Ocean, and/or • Disturtied area Is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical, and/or • Disturt)ed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse, and/or • Construction will be initiated during the rainy season or will extend into the rainy season (Oct 1 through April 30). T/er3 - Significant Threat Assessment Criteria • My project includes clearing, grading or other disturbances to the ground resulting in soil disturbance totaling one or more acres including any associated constmctbn staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas: and/or • My project is part of a phased development plan that will cumulatively result in soil disturtiance totaling one or more acres Including any associated constnjction staging, equipment storage, refueling and maintenance areas: or, • My project Is located inside or within 200 feet of an environmentally sensitive area (see City ESA Pniximlty map) and has a significant potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-stonn water discharge(s). / certify to the best of my knowledge that the above checked statements are true and correct I understand and acknowledge that even though this project does not require preparation of a constructton SWPP, I must sttll adhere to, and at all ttmes during construction activities for the permit (ypefs) check above comply with the storm water best management practices pursuant to Title 15 ofthe Carlsbad Municipal Code and to Citv Standards. •The City Engineer may authorize nninor variances from the Storm Water Threat Assessment Criteria in special circumstances where it can be shown that a lesser or higher Constmction SWPPP Tier Level is warranted. B-24 Project Address^ / ^ Assessor Parcel No. Ownei^Ownar'sAutibrizsdAgant^iSlf^ ^ V . • Date: V/ r/. CityCcnotirrence: WY^QNO / By:/ $^17^ Project II}: Page Rev.03/09 PLAN CHECK ^ CITY OF PLAN CHECK Community & Economic ^ CITY OF REVIEW Development Department 1635 Faraday Avenue CARLSBAD TRANSIVIITTAL Carlsbad CA 92008 www.carlsbadca.gov DATE: July 20, 2012 PROJECT NAME: PROJECT ID: PLAN CHECK NO: CB 12-1117SET#: 2 ADDRESS: 2550 Gateway Rd APN: 213-261-15-05 • This plan check review is complete and has been APPROVED by the Planning Division. By: Chris Sexton A Final Inspection by the Planning Division is required • Yes ^ No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: Ware Malcomb (Kim Stone) Vou may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the foiiowing reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 X Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.gov Greg Ryan 760-602-4663 Gregorv.Rvan@carlsbadca.gov 1 1 Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov 1 1 Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov 1 1 Cindy Wong 760-602-4662 Cvnthia.Wong@carlsbadca.gov • 1 1 Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.gov Remarks: ^ CITY CARLSBAD O F PLANNING DIVISION BUILDING PLAN CHECK REVIEW CHECKUST P-28 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov REVIEW #: 1 2 3 S • • • • • • • • • • Plan Check No. CB 12-1117 Address 2550 Gatewav Road Date 6/18/12 Review # 2 Planner Chris Sexton Phone (760) 602-4624 APN; 213-261-15-05 Type of Project & Use: H Net Project Density:N/A DU/AC Zoning: P£ General Plan: PJV1 Facilities !\/lanagement Zone: 17 CFD (In/out) #_Date of participation: Remaining net dev acres: (For non-residential development: Type of land use created by this permit: ) Legend: ^ Item Complete • Item Incomplete - Needs your action Environmental Review Required: YES • NO • TYPE DATE OF COIVIPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES • NO • TYPE APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: • • Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES Q NO • CA Coastal Commission Authority? YES Q NO • If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt); IHabitat Management Plan Data Entry Completed? YES • NO • If property has Habitat Type identified in Table 11 of HIVIP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) Inclusionary Housing Fee required: YES Q NO • (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES • NO • (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) Housing Tracking Form (form P-20) completed: YES • NO • N/A • p-28 Page 1 of 2 07/11 Site Plan: S • • Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of- way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. City Council Policy 44 - Neighborhood Architectural Design Guidelines lEI • • 1. Applicability; YES • NO • • • • 2. Project complies; YES • NOO • • • • Zoning: 1. Setbacks: Front; Interior Side: Street Side; Rear; Top of slope; Required, Required. Required. Required. Required. 2. Accessory structure setbacks; Front; Required. Interior Side: Required. Street Side; Required. Rear: Required. Structure separation: Required. Shown Shown, Shown, Shown, Shown Shown. Shown. Shown. Shown. Shown s • • ^ • • • s • 3. Lot Coverage: 4. Height; 5. Parking: Required, Required, Spaces Required. Shown Shown Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments 1) Ploase show how now roof mounted equipment will bo screenedr Please see attached handout. OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER Chris Sexton DATE July 20. 2012 PLAN CHECK Community & Economic CITY OF REVIEW Development Department 1635 Faraday Avenue CARLSBAD TRANSMITTAL Carlsbad CA 92008 www.carlsbadca.gov DATE: June 18, 2012 PROJECT NAME: PROJECT ID: PLAN CHECK NO: CB 12-1117SET#: 1 ADDRESS: 2550 Gateway Rd APN: 213-261-15-05 Q This plan check review is complete and has been APPROVED by the Division. By: A Final Inspection by the Division is required • Yes • No ^ This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: Ware Malcomb (Kim Stone) You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 X Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.gov 1 Greg Ryan 760-602-4663 Gregorv.Rvan@carlsbadca.gov 1 1 Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov 1 1 Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov 1 1 Cindy Wong 760-602-4662 Cvnthia.Wong@carlsbadca.gov • • 1 1 Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.gov Remarks: ^ CITY CARLSBAD O F PLANNING DIVISION BUILDING PLAN CHECK REVIEW CHECKLIST P-28 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbaclca.gov Plan Check No. CB 12-1117 Address 2550 Gatewav Road Date 6/18/12 Review # 1 Planner Chris Sexton Phone (760) 602-4624 APN: 213-261-15-05 Type of Project & Use: J\ Net Project Density;N/A DU/AC Zoning; General Plan: PM Facilities Management Zone: 17 CFD (in/out) #_Date of participation; Remaining net dev acres: (For non-residential development: Type of land use created by this permit: ) REVIEW #: 1 2 3 lEi • • • • Legend: |^ Item Complete G Item Incomplete - Needs your action Environmental Review Required: YES • NO • TYPE DATE OF COMPLETION; Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval; - Discretionary Action Required: YES • NO • TYPE APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval; G D Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES O NO Q CA Coastal Commission Authority? YES Q NO Q If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): G Q Habitat Management Plan Data Entry Completed? YES G NO G If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar. Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) G G Inclusionary Housing Fee required: YES G NO G (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES G NO G (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) G • Housing Tracking Form (form P-20) completed: YES G NO G N/A G p-28 Page 1 of 2 07/11 Site Plan: S G G Provide a fully dimensional site plan drawn to scale. Show; North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of- way width, dimensional setbacks and existing topographical lines (including ali side and rear yard slopes). Provide legal description of property and assessor's parcel number. City Council Policy 44 - Neighborhood Architectural Design Guidelines lEI G G 1. Applicability; YES G NO G G G G 2. Project complies: YES G NOQ G G G G ^ G G ^ G G ^ G G G G G Zoning: 1. Setbacks: Front: Interior Side; Street Side: Rear: Top of slope: Required Required Required, Required, Required, 2. Accessory structure setbacks: Front; Required. Interior Side: Required. Street Side: Required. Rear; Required. Structure separation: Required. 3. Lot Coverage; 4. Height: 5. Parking; Required, Required Spaces Required. Shown. Shown Shown. Shown. Shown Shown Shown Shown, Shown. Shown Shown Shown Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments 1) Please show how new roof mounted eauipment will be screened. Please see attached handout OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE CITY CARLSBAD O F PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov DATE: 8/10/12 PROJECT NAME: audacity group PROJECT ID: PLAN CHECK NO: cbl21117 SET#: ADDRESS: 2550 gateway rd APN: ^ This plan check review is complete and has been APPRKEBI^ tfiffilrf tfSQfiiY By: cwong A Final Inspection by the Division is required |^ Yes • No • This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 1 1 Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.gov 1 Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.gov Q Greg Ryan 760-602-4663 Grefiorv. Rva n@ca risbadca .gov 1 1 Gina Ruiz 760-602^675 Gina.Ruiz@carlsbadca.gov 1 1 Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov X Cindy Wong 760-602-4662 Cvnthia.Wong@carlsbadca.gov • • 1 Dominic Fieri 760-602-4664 Domlnic.Fieri@carlsbadca.gov *** Slip Sheet approved Sheets A0.1, Al .1 and A2.1 into City AND Owner sets for approval to be valid **** Carlsbad Fire Department Plan Review Requirements Category: TI, INDUST Date of Report: 08-10-2012 Reviewed by: Name: Address: KIM STONE • WARE MALCOMB 6363 GREENWICH DR., STE. 175 SAN DIEGO CA 92122 BLDG. DEPT COPY Permit #: CB121117 Job Name: AUDACITY GROUP: SHELL TO OFF. Job Address: 2550 GATEWAY RD CBAD INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review careftilly all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions; Cond: CON0005583 [NOT MET] ***** Make appointment to satisfy the following conditions for Recommended Approval by Daryl K James and Fire Dept. Call to 760-602-4662 to schedule an appointment for M-Th. **** 1. Sheet AO.l : Revise as there are (2) E3 sheets listed. 2. Sheet Al. 1 : Revise OLF in conference room to 15 3. Sheet A2.1 : Move Fire extinguisher cabinet towards fi-ont door at entrance along path of egress. Entry: 07/30/2012 By: cwong Action: CO Cond; CON0005603 [MET] *** Slip Sheet approved Sheets AO.l, Al.l and A2.1 into City AND Owner sets for approval to be valid **** * "^APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS, f THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. Entry: 08/10/2012 By: cwong Action: AP ^ CITY OF CARLSBAD PLAN CH^CK. p.ppTPfu^^"'""'*^*^""""'" RFX/IFW"-^" ^^^^ '^^bevfelopment Department KCVICW 1635 Faraday Avenue TRANSMITTAL carisbad CA 92OO8 www.carlsbadca.gov DATE: 7/30/12 PROJECT NAME: Audacity Group PROJECTID: PLAN CHECK NO: cbl21117 SET#: ADDRESS: 2550 gateway Road APN: • This plan check review is complete and has been APPROVED by the fire Division. By: A Final Inspection by the Division is required |^ Yes G No ^ This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sertt to: 858-638-7506 Vou may a/so have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760^02-2750 FIRE PREVENTION 760602-4665 1 Chris Sexton 760-602-4624 Ch ris.Sexton@carlsbadca.gov 1 Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.gov 1 1 Greg Ryan 760-602-4663 Gregory.Ryan@carlsbadca.gov 1 1 Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov 1 1 Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov X Cindy Wong 760-602-4662 Cvnthia.Wong@carlsbadca.gov • • 1 Dominic Fieri 760-602-4664 Dominjc.Fieri@carlsbadca.gov ***** Make appointment to satisfy the following conditions for Recommended Approval by Daryl K James and Fire Dept. Call to 760-602-4662 to schedule an appointment for M-Th. **** 1. Sheet AO.l: Revise as there are (2) E3 sheets listed. 2. Sheet A1.1: Revise OLF in conference room to 15 3. Sheet A2.1; Move Fire extinguisher cabinet towards front door at entrance along path of egress. Carlsbad Fire Department Plan Review Requirements Category: TI, INDUST Date of Report; 07-30-2012 Reviewed by; Name: KIM STONE Address: WARE MALCOMB 6363 GREENWICH DR., STE. 175 SAN DIEGO CA 92122 Permit #: CB121117 Job Name: AUDACITY GROUP: SHELL TO OFF. OQ Job Address: 2550 GATEWAY RD CBAD INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond; CON0005583 [NOT MET] ***** Make appointment to satisfy the following conditions for Recommended Approval by Daryl K James and Fire Dept. Call to 760-602-4662 to schedule an appointment for M-Th. * * * * 1. Sheet AO. 1 ; Revise as there are (2) E3 sheets listed. 2. Sheet Al.l : Revise OLF in conference room to 15 3. Sheet A2.1 : Move Fire extinguisher cabinet towards front door at entrance along path of egress. Entry: 07/30/2012 By: cwong Action: CO BLDG. DEPT COPY fage 1 ot z CONDITIONAL RECOMMENDATION FOR APPROVAL CONDITIONS: Correct the following over the counter on & Fire & Building Dept. plans. E3 is listed twice. Revise last E sheet to E-4 Re-label office to conference room. Revise occupant load factor to 15 in lieu of ICQ. Occupant load is correct. Daryl K. James & Associates, Inc. Checked by: Daryl Kit James 205 Colina Terrace Date: July 23.2012 V Wsfa, CA 92084 ^ \ ' T. (760) 724-7001 Email: kitfire@sbcglobal.net 'X^ ' APPLICANT: Kim Stone JURISDICTION: Carlsbad Fire Department . PROJECT NAME: Audacity Group PROJECT ADDRESS: 2550 Gateway Road Ste 1 ' , PROJECT DESCRIPTION: CB121117 3,4830] First generation Tl to (e) office space This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted ^ by the Carlsbad Fire Department. ~? The items below require correction, clarification or additional information before this plan check can be approved ^ for permit issuance. COMMENTS - Additional comments made be generated by response on revised set. -surf"' Project Data iJ k^List the following list of deferred submittals as follows: Fire Sprinkler System 2010 GFC 903 and 2010 NFPA 13. ^ Fire Alarm System 2010 CFC 907.2.2 and 2010 NFPA 72 V • Denote occupancy classification of adjacent tenant, if space is occupied /i r '>>^ Deferred Submittals —/-^A ^ Sheet Index E3 is listed twice. Revise last E sheet to E-4 Occupant load is correct but, show occupant load factor as 15 in lieu of 100. Please correct over the counter. n^'^ Plumbing sheets and list in accordance with sheet placement. ^ ^ AQ.2 Revise the Following Ceiling Note fc^lO. Sprinkler plans approved by the Carlsbad Fire Dept. for review and comment prior to installation. Door Notes k/2>. Revise note to read, "This door to remain unlocked whenever building is occupied". Al.l Denote the square footage, occupant load factor and occupant load for each room based on the function of the room in accordance with CBC Table 1004.1.1. i/Qccupant loads are to be calculated using 15 square feet per occupant in break rooms and conference rooms. Occupant load is correct but, show occupant load factor as 15 in lieu of 100. Please correct over the counter. Fage 2 ot Z i''Denote the aggregate square footage, required number of exits, required and actual width of exits. CBC 1005 • Show number of occupants exiting each door in exit discharge. (Occupants in break rooms need not be counted twice) A4.1 • Plan Specific Notes Provide Note 8. • Provide symbols and denote locations of new and existing exit signs and means of egress illumination on Reflected Ceiling Plan CBC 1006 & CBC 1011 or provide a reference to Electrical Lighting Plan E-2.A. • Provide this note: Means of egress illumination to be not less than 1-foot candle illumination at the walking surface. CBC 1006.2 A5.1 Provide a note: All finish materials shall comply with CBC Chapter 8. A7.1 Notes •Add a note: All doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Hardware Group • Door 106 Justify indicator hardware. Clarify if this is keyed locking device. Keyed locking devices are only permitted on the Main exterior door. Operating Hardware • Provide a description of how 2d is readily openable without the use of a key, special knowledge or effort. Hardware Specifications •Clarify where hardware specifications are denoted on Door Schedule. E-1 • Label this sheet. • Provide symbols list E-2 • Label this sheet. • Provide symbols list. E-2A Symbols List • Provide symbols list for lighting plan. CBC 1006 & CBC 1011. • Provide this note: Means of egress illumination to be not less than 1-foot candle illumination at the walking surface. CBC 1006.2 CORRECTION LIST Fage 1 ot J BLDG. DEPT COPY Daryl K. James & Associates, Inc. 205 Colina Terrace Vista, CA 92084 T. (760) 724-7001 Email: kitfire@sbcglobal.net Checked by: Daryl Kit James Date: June 18. 2012 APPLICANT: Kim Stone JURISDICTION: Carlsbad Fire Department PROJECT NAME: Audacity Group PROJECT ADDRESS: 2550 Gateway Road Ste 1 PROJECT DESCRIPTION: CB121117 3,483[I] First generation Tl to (e) office space This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. The items below require correction, clarification or additional information before this plan check can be approved for permit issuance. INSTRUCTIONS FOR EXPEDITED PLAN REVIEW SERVICE - CORRECTIONS OR MODIFICATIONS TO THE PLANS MUST BE CLOUDED AND PROVIDED WITH NUMBERED DELTAS AND REVISION DATES ALONG WITH A DESCRIPTIVE NARRATIVE OF CORRECTIONS ADDRESSING ALL COMMENTS. PLEASE BE SURE TO PUT FIRE REVISIONS ON THE BUILDING DEPT. PLAN CHECK SET. - PLEASE DIRECT ANY QUESTIONS REGARDING THIS REVIEW TO: DARYL K. JAMES 760-724-7001 OR KITFIRE@SBCGLOBAL.NET • CORRECTED PLANS, DESCRIPTIVE NARRATIVE OF REVISIONS FOLLOWING EACH COMMENT ON THIS FORM, AND A COPY OF BUILDING DEPARTMENT (ESGIL) • ONE COMPLETE PLAN CHECK SET MUST BE DELIVERED DIRECTLY TO THE FOLLOWING ADDRESS TO AVOID DELAY: DARYL K. JAMES & ASSOCIATES, INC. 205 COLINA TERRACE VISTA, CA 92084 COMMENTS - Additional comments made be generated by response on revised set. AO.l Project Data Denote occupancy classification of adjacent tenant, if space is occupied Deferred Submittals List the following list of deferred submittals as follows: Fire Sprinkler System 2010 CFC 903 and 2010 NFPA 13. Fire Alarm System 2010 CFC 907.2.2 and 2010 NFPA 72 Sheet Index Revise Plumbing sheets and list in accordance with sheet placement. A0.2 Revise the Following Ceiling Note 10. Sprinkler plans approved by the Carlsbad Fire Dept. for review and comment prior to installation. Door Notes 3. Revise note to read, "This door to remain unlocked whenever building is occupied". Fage Z ot .5 Al.l Denote the square footage, occupant load factor and occupant load for each room based on the function of the room in accordance with CBC Table 1004.1.1. Occupant loads are to be calculated using 15 square feet per occupant in break rooms and conference rooms. Denote the aggregate square footage, required number of exits, required and actual width of exits. CBC 1005 Show number of occupants exiting each door in exit discharge. (Occupants in break rooms need not be counted twice) A4.1 Plan Specific Notes Provide Note 8. Provide symbols and denote locations of new and existing exit signs and means of egress illumination on Reflected Ceiling Plan CBC 1006 & CBC 1011 or provide a reference to Electrical Lighting Plan E-2.A. Provide this note: Means of egress illumination to be not less than 1-foot candle illumination at the walking surface. CBC 1006.2 A5.1 Provide a note: All finish materials shall comply with CBC Chapter 8. A7.1 Notes Add a note: All doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Hardware Group Door 106 Justify indicator hardware. Clarify if this is keyed locking device. Keyed locking devices are only permitted on the Main exterior door. Operating Hardware Provide a description of how 2d is readily openable without the use of a key, special knowledge or effort. Hardware Specifications Clarify where hardware specifications are denoted on Door Schedule. E-1 Label this sheet. Provide symbols list E-2 Label this sheet. Provide symbols list. E-2A Symbols List Provide symbols list for lighting plan. CBC 1006 & CBC 1011. Provide this note: Means of egress illumination to be not less than 1-foot candle illumination at the walking surface. CBC 1006.2 PROJECT NUMBER I, will be levied a administration fee CARLSBAD FIRE DEPARTMENT EXPEDITED PLAN CHECK REQUEST ^ am requesting 'Expedited Plan Check Services' and understand I assessed at the rate of $90.00 dollars per hour plus $25.00 dollars I understand that my plans shall not be released until all fees are paid. ^the applicant, am solely responsible for all fees due should the project be withdraVJn or otherwise not completed. And by signing below I acknowledge that my plans shall be forwarded by the City of Carlsbad to an independent contractor/consultant. i, acknowledge that the 'first review' time for all expedited Fire plan reviews will be fourteen- (14) business days from date of submittal. These additional day account for acceptance and delivery of your plans and then the parcel return to our office if recommended for approval. the applicant, acknowledges that corrected or revised plans shall be sent directly to the plan checker, at the address specified on the Correction List, at my cost, parcel post or other means. acknowledge that a turn-around time for re-submittals is seven- (7) busilSess days from the date plans are received at the address specified by the plan checker on the Correction List. Once all corrections are made, your plans are then returned to the Carlsbad Fire Department with a "Recommendation for Aooroval" based solely on the adopted Codes and Standards. This is not a full approval. Your plans are then forwarded to the Carlsbad Fire Department, and once your plans are received by our office they are subject to an additional review to ensure conformance with Carlsbad Municipal Code. This additional review is subject to an additional review period of seven- (7) days from date that we receive the plans from the plan reviewer. The Carlsbad Fire Department does not perform 'Over-the-counter' plan review services. Plans submitted to the Carlsbad Fire Departmentforjieview by CFD staff shall be checked on a 'first come, first served' basis and could take 60 days or nripr^Jo-h^ completed. NO Applicant Signature Copy to Builcling and Fire Preventl&n 0.,. /Mzv/z- Revised 11/07/2011 TITLE 24 REPORT Title 24 Report for: The Collection at Bressi Ranch - Building B Carlsbad, Ca Project Designer: Ware Malcomb 9605 Scranton Road. Suite 310 San Diego, Ca 92121 858 638 7277 Report Prepared By: Robert H Foster FOG Consulting Engineers 17701 Cowan, Suite 230 Irvine, CA 92614 (949) 253 9630 Job Number: 06-165 Date: 7/2/2012 The EnergyPro computer program has been used to perform the calculations summarized In this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.eneravsoft.com. EnergyPro 4.4 by EnergySoft Job Number: 06-165 User Number: 5670 Cdn-iin TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Nonresidential Performance Title 24 Forms 3 Form ENV-MM Envelope Mandatory Measures 11 Form MECH-MM Mechanical Mandatory Measures 12 EnergyPro 4.4 by EnergySoft Job Number: 06-165 User Number: 5670 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF-1 PROJECT NAME The Collection at Bressi Ranch - Building B DATE 7/2/2012 PROJECT ADDRESS Carlsbad PRINCIPAL DESIGNER - ENVELOPE Ware Malcomb TELEPHONE 858 638 7277 Building Permit # DOCUMENTATION AUTHOR FDG Consulting Engineers TELEPHONE (949) 253 9630 Checked by/Date Enforcement Agency Use GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA 10-23-06 1 5,346 Sq.Ft. CLIMATE ZONE BUILDING TYPE [X] NONRESIDENTIAL • HIGH RISE RESIDENTIAL I I HOTEUMOTEL GUEST ROOM PHASE OF CONSTRUCTION \X\ NEW CONSTRUCTION LH ADDITION I I EXISTING + ADDITION/ALTERATION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is accurajp anrf TI DOCUMENTATION AUTHOR Robert IH Foster SIGNATURE DATE Ttie Principal Designer hereby certifys that the proposed building design represented in tliis set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116, through 118, and 140, 142, 143 or 149 of Title 24, Parte. ENV. LTG. MECH. I I I I I I 1.1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect. I j I II I 2. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section — 5537,2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. I > I I Q] 3. I affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections ofthe Business and Professions Code are printed in full in the Nonresidential IVlanual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Required Forms ENV-1 PRINCIPAL ENVELOPE DESIGNER - NAME Ware Malcomb SIGNATURE LIC. NO. DATE LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Required Forms Lighting Compliance Not In The Scope Of TtTis^Sutjnrittal PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE Lie. NO. DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Required Forms IVlECH-1, MECH-2, MECH-3, MECH-5 PRINCIPAL MECHANICAL DESIGNER - NAME FDG Consulting Engineers Inc. SIG^^^^^^ Lie. NO. DATE 1 Run Initiation Time: 07/02/12 17:23:57 RunCode: 1341275037 j 1 EnergyPro 4.4 by EnergySoft User Number 5670 Job Number: 06-165 Page:3of13 | PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF-^ PROJECT NAME The Collection at Bressi Ranch - Builcling B DATE 7/2/2012 ANNUAL TDV ENERGY USE SUMMARY (kBtu/sqft-vr) standard Proposed Compliance ENERGY COMPONENT Design Design Margin B Standanl • ProfXMOd Space Heating 1.96 0.94 1.02 SfKR«H«e(lns Space Cooling 97.52 69.18 28.34 Spaca Cooing Space Cooling 97.52 69.18 28.34 Spaca Cooing Indoor Fans 42.43 41.02 1.41 Indoor Fam Heat Rejection 0.00 0.00 0.00 HMlRajocUon Pumps & Misc. 0.00 0.00 0.00 Pufn|»&Mlsc Domestic Hot Water 0.00 0.00 0.00 DHW Lighting UoMna Lighting 66.73 66.73 0.00 : ••••••••••HHI J - "™ Receptacle RMoptado' Receptacle 74.99 74.99 0.00 RMoptado' Process 0.00 0.00 0.00 Pracoos TOTALS: Percent better than Standard: 283.63 252.86 30.77 30 40 kBtu/sqft-yr 50 60 70 SO 10.8% ( 10.8% excluding process) BUILDING COMPLIES GENERAL INFORMATION Building Orientation Number of Stories Number of Systems Number of Zones (N) 0 deg Conditioned Floor Area Unconditioned Floor Area Conditioned Footprint Area Fuel Type 15,346 0 7,673 Natural Gas sqft. sqft. sqft. Orientation Gross Area Front Elevation (N) 3,518 sqft. 612 sqft. 17.4% Left Elevation (E) 1,800 sqft. 472 sqft. 26.2% Rear Elevation (S) 3,452 sqft. 986 sqft. 28.6% Right Elevation (W) 1,800 sqft. 462 sqft. 25.7% Total 10,570 sqft. 2,532 sqft. 24.0% Roof 7,673 sqft. 0 sqft. 0.0% Standard Proposed Lighting Power Density Prescriptive Env. Heat Loss Prescriptive Env. Heat Gain 1.100 5,998 291,672 W/sqft. Btu/h Btu/h-F 0.000 5.781 274,678 W/sqft. Btu/h Btu/h-F Remarks: Run Initiation Time: 07/02/12 17:23:57 RunCode: 1341275037 EnergyPro 4.4 by EnergySoft User Number: 5670 Job Number: 06-165 Page: 4 of 13 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF-1 PROJECT NAME The Collection at Bressi Ranch - Building B DATE 7/2/2012 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sqft.) Inst. LPD (W/sf)1 Ctrl. Credits (W/sf)2 Allowed LPD Proc. Loads (W/sf) System Name Zone Name Occupancy Type Floor Area (sqft.) Inst. LPD (W/sf)1 Ctrl. Credits (W/sf)2 Area (W/sf) 3 Tailored (W/sf)"* Proc. Loads (W/sf) Building B -1st Floor Building B -1st Floor Comp BIdg Office 7,673 0.000 Building B - 2nd Floor Building B - 2nd Fir Comp BIdg Office 7,673 0.000 1 Notes: 1. See LTG-2-C 2. See LTG-4-C 3. See LTG-5-C 4. See LTG-6-C (items marked with asterisl<, see LTG-2 -C by others) (by others) Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the Items specified in this checklist These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System "Carrier 50HJQ006" is designated as 3 Phase, or is Exempted from the NAECA 13 SEER requirement. The HVAC System "Carrier 25HBR348/FC4D048" is designated as 3 Phase, or is Exempted from the NAECA 13 SEER requirement. The HVAC System "Building B -1st Floor" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The HVAC System "Building B - 2nd Floor" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant 1 Run Initiation Time: 07/02/12 17:23:57 RunCode: 1341275037 1 1 EnergyPro 4.4 by EnergySoft User Number: 5670 Job Number: 06-165 Page:5of13 j CERTIFICATE OF COMPLIANCE ENV-1-C PROJECT NAME The Collection at Bressi Ranch - Building B DATE 7/2/2012 OPAQUE SURFACES # Surface Type Area U-Fac. Insulation Cav. Cont. Act. Azm. Tilt Cond.* Status Joint Appendix IV Reference Location / Comments 1 Wall 1,456 0.410 Filled R-0.0 0 90 New 12-C9 iBuildinq B-1st Floor 2 Wall 198 0.138 None R-11.0 0 90 New 15-A1 Building B -1st Floor 3 Wall 667 0.410 Filled R-0.0 270 90 New 12-C9 Building B -1st Floor 4 Wall 1,102 0.410 Filled R-0.0 180 90 New 12-C9 Building B -1st Floor 5 Wall 132 0.138 None R-11.0 180 90 New 15-A1 Building B -1st Floor 6 Wall 667 0.410 Filled R-0.0 90 90 New 12-09 Building B -1st Floor 7 Wall 661 0.410 Filled R-0.0 90 90 New 12-09 Building B - 2nd Fir 8 Wall 1,252 0.410 Filled R-0.0 0 90 New 12-09 Building B - 2nd Fir 9 Wall 671 0.410 Filled R-0.0 270 90 New 12-09 Building B - 2nd Fir 10 Wall 1,232 0.410 Filled R-0.0 180 90 New 12-09 Building B - 2nd Fir 11 Roof 7,673 0.032 R-30 R-0.0 0 0 New 01-A17 Building B - 2nd Fir * N, E, A, R (New. Existing, Altered, Removed) FENESTRATION SURFACES More than or equal to 10.000 sq.ft. of site-built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default U-factors from Standards Table 116-A and B. Certificate s # Type Area U-Fac.^ SHGC Act. Azm. Cond. Stat. Glazing Type Location/ Comments 1 Window Front (N) 204 0.920 NFRC 0.50 NFRC 0 New Versalux Blue 2000 Building B -1st Floor 2 Window Right (W) 233 0.920 NFRC 0.50 NFRC 270 New Versalux Blue 2000 Building B -1st Floor 3 Window Rear (S) 558 0.920 NFRC 0.50 NFRC 180 New Versalux Blue 2000 Building B -1st Floor 4 Window Left (E) 233 0.920 NFRC 0.50 NFRC 90 New Versalux Blue 2000 Building B -1st Floor 5 Window Left (E) 239 0.920; NFRC 0.50 NFRC 90 New Versalux Blue 2000 Building B - 2nd Fir 6 Window Front (N) 408 0.920iNFRC 0.50 NFRC 0 New Versalux Blue 2000 Building B - 2nd Fir 7 Window Right (W) 229 0.920 NFRC 0.50 NFRC 270 New Versalux Blue 2000 Building B - 2nd Fir 8 Window Rear (S) 428 0.920 NFRC 0.50 NFRC 180 New Versalux Blue 2000 Building B - 2nd Fir (1) U-factor Type: 116-A Default Table from Standards, Table NI-1 Default Table from the ACM Manual Appendix, NFRC Labeled value. (2) SHGC Type; 116-B Default Table from Standards. COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin # Exterior Shade Type SHGC Window Hgt. Wd. Len. Hgt. LExt.RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 None 0.76 2 None 0.76 3 None 0.76 10.0 11.8 4.0 0.1 4.0 4.0 0.0 0.0 0 0.1 2.0 0 4 None 0.76 5 None 0.76 10.0 28.0 4.0 0.1 4.0 4.0 0.0 0.0 0 0.1 2.0 0 6 None 0.76 7 None 0.76 8 None 0.76 10.0 11.8 4.0 0.1 4.0 4.0 0.1 2.0 0 0.0 0.0 0 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES • The proposed building is in climate zones 2 through IS and contains an enclosed space with floor area greater than 25,000 ft2, a ceiling height greater than 15 feet, and an LPO for general lighting of at least 0.5 W/ft2. See Section 143(c). If this box is checked, ENV-4-C must be filled out. when submitting under the Prescriptive Compliance Approach. 1 Run Initiation Time: 07/02/12 17:23:57 RunCode: 1341275037 1 1 EnergyPro 4.4 by EnergySoft User Number: 5670 Job Number: 06-165 Page:6of13 | CERTIFICATE OF COMPLIANCE MECH-1-C PROJECT NAME The Collection at Bressi Rancli - Building B DATE 7/2/2012 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM IManual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space-conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-1-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of Section 10-103(b) and Title 24 Part 6. STATEMENT OF COMPLIANCE I IIV1ECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. I I MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing res( required on all New systems both New Construction and Retrofit I I MECH-4-A: Air-Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Constmction and Retrofit. Units with economizers that are installed at the factory and certified with the commission do not require equipment testing but do require construction inspection. I I MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing This test required If the unit serves 5,000 ft2 of space or less and 25% or more ofthe ducts are in nonconditioned or semiconditloned space like an attic. New systems lhat meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or replace the packaged unit. \ j MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new DCV controls Installed on new or existing packaged systems must be tested. i I MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VAV fan volume controls installed on new or existing systems must be tested I I l\/1ECH-8-A; -Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chllled and hot water systems. -Automatic Isolation Controls Applies to new boilers and chUlers and the primary pumps are connected to a common header -Supply Water Temperature Reset Controls Applies to new constant flow chilled and hot water systems that have a design capacity greater than or equal to 500.000 Btu/hr. -Water-loop Heat Pump Controls Applies to alt new waterloop heat pump systems where the combined loop pumps are greater than 5 hp. -Variable Frequency Controls Applies to all new distribution pumps on new variable flow chilled, hydronic heat pump or condenser water systems where the pumps motors are greater than 5 hp. Equipment requiring acceptance testing EnergyPro 4.4 by EnergySoft User Number: 5670 Job Number: 06-165 Page:7 of 13 AIR SYSTEM REQUIREMENTS Part lof 2 MECH-2-C PROJECT NAME DATE The Collection at Bressi Ranch - Building B 7/2/2012 SYSTEM FEATURES AIR SYSTEMS, Central or Single Zone Building B -1st Floor Building B - 2nd Floor 4 4 T-24 Section Reference on Plans or Specification ' 112(a) 8.40 HSPF 7.70 HSPF 112(a) 13.0 SEER/11.0 EER 13.0 SEER/11.0 EER 112(b) Yes Yes 112(c), 115(a) n/a n/a 121(b) Yes Yes 121(b) 1151 cfm 1151 cfm 121(c) No No 121(c) No No 121(c), 122(e) Programmable Switch Programmable Switch 122(e) No Setback Required No Setback Required 122(f) Auto Auto 122(g) n/a n/a 123 124 R-4.2 R-4.2 144 (a & b) n/a n/a 144 (a&b) 146,878 btuh 171,969 btuh 144 (a&b) n/a n/a 144 (a & b) 153,007 btuh 193,503 btuh 144 (c) Constant Volume Constant Volume 144 (c) 144 (c) Yes Yes 144 (d) No No 144 (e) No Economizer No Economizer 144 (f) Constant Temp Constant Temp 144 (f) Constant Temp Constant Temp 144 (k) No No ITEM OR SYSTEM TAG(S) Number of Systems MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity xl .43^ Proposed Heating Capacity ^ Calculated Sensible Cooling Capacity x 1.21 Proposed Sensible Cooling Capacity ^ Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset 3 Duct Sealing for Prescriptive Compliance 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference ot plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sqft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF-1 for performance method duct sealing requirements. INOTES TO FIELD - For Buildina Department Use Onlv ~ Run Initiation Time: 07/02/12 17:23:57 RunCode: 1341275037 EnergyPro 4.4 by EnergySoft User Number: 5670 Job Number: 06-165 Page:8 of 13 MECHANICAL VENTILATION MECH-3-C PROJECT NAME Tiie Collection at Bressi Ranch - Building B DATE 7/2/2012 PRESCRIPTIVE REHEAT LIMITATION (Section 144(d)) MECHANICAL VENTILATION (Section 121(b)2) PRESCRIPTIVE REHEAT LIMITATION (Section 144(d)) AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C D E F G H 1 J K L M N ZONE/SYSTEM Condition Area (SF) CFM per Square Foot Min CFM by Area (BxC) Number of People CFM per Person Min CFM by Occupant (ExF) REQ'D V.A Max of (D or G) Design Vent. Air CFM 30% of Design Zone Supply CFM BxO.4 CFM/sq. ft. Max of Columns H, J, K or 300 CFM Design Min. Air Setpoint Transfer Air Building B -1st Floor 7,673 0.15 1,151 1,151 1,151 Building B -1st Floor Total 1,151 1,151 Building B - 2nd Fir 7,673 0.15 1,151 1,151 1,151 Building B - 2nd Floor Total 1,151 1,151 1 I j i Minimum ventilation rate per Section 121, Table 121-A Based on fixed seat or the greater of ttie expected number of occupants and 50% of the CBC occupant load for egress purposes for spaces without fixed seating. Required Ventilation Air (REQ'D V.A.) is the larger of the ventilation rales calculated on and AREA or OCCUPANCY BASIS (column D or G). Must be greater than or equal to H, or use Transfer Air (column N) to make up ttie difference. Design fan supply cfm (Fan CFM) x 30%; or Condition area (ft. sq.) x 04 cfm/ft. sq.; or Maximum of Columns H, J, K, or 300 cfm This must be less than or equal to Column L and greater that or equal to the sum of Columns H ^ N. N Transfer air must be provided where the Required Ventilation Air (column I) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (column I) and the Design Minimum Air (column M). column H - M. EnergyPro 4.4 by EnergySoft User Number: 5670 Job Number: 06-165 Page: 9 of 13 MECHANICAL EQUIPMENT DETAILS Parti of2 MECH-5-C PROJECT NAME The Collection at Bressi Ranch - Building B DATE 7/2/2012 CHILLER AND TOWER SUMMARY Efficiency Tons PUMPS Equipment Name Equipment Type Qty. Efficiency Tons Tot. Qty GPM BHP Motor Eff. Drive Eff. Pump Control DHW/BOILER SUMMARY System Name System Type Distribution Type Qty Rated Input Vol. Condition (Gals.) Status Energy Factor or RE Standby Loss or Pilot TANK INSUL. Ext. R-Val. Hot Water Pump Hot Water Piping Length (ft) Control # HP Type In Plenum Outside Buried Add 1/2" Insulation MULTI-FAMILY CENTRAL WATER HEATING DETAILS CENTRAL SYSTEM RATINGS HEATING COOLING System Name System Type Qty Output Aux. kW Eff. Output Efficiency Condition Status Economizer Type Carrier 25HBR348/FC4D048 Split DX 4 48,000 0.0 8.40 HSPF 46,500 13.0 SEER /11.0 EER New No Economizer Carrier 50HJQ006 Packaged DX 4 56,200 0.0 7.70 HSPF 63,800 13.0 SEER/11.0 EER New No Economizer CENTRAL SYSTEM FAN SUMMARY SUPPL1 rFAN RETUR N FAN System Name Fan Type Motor Location CFM BHP Motor Eff. Drive Eff. CFM BHP Motor Eff. Drive Eff. Carrier 25HBR348/FC4D048 Constant Volume Blow-Through 1,600 0.75 77.0% 100.0% none Carrier 50HJQ006 Constant Volume Blow-Through 2,000 1.00 82.5% 100.0% none Run Initiation Time: 07/02/12 17:23:57 RunCode: 1341275037 EnergyPro 4.4 by EnergySoft User Number: 5670 Job Number: 06-165 Page:10of13 ENVELOPE MANDATORY MEASURES ENV-MM PROJECT NAME The Collection at Bressi Ranch - Building B DATE 7/2/2012 DESCRIPTION Designer Enforcement [X] § 118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. I I § 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. |Xl § 117(3) All Exterior Joints and openings In the building that are observable sources of air leakage shall be caulked, gasketed, weatherstrlpped or otherwise sealed. I [ § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstrlpped (except for unframed glass doors and fire doors). [X] S 116(a)1 Manufactured Doors and Windows Installed shall have air Infiltration rates not exceeding those shown in Table Number 1-E. ofthe Standards. Manufactured fenestration products must be labeled for U-value according to NFRC procedures. § 118(e) Demising Walls In Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R-value of no less than R-13 between framing members. EnergyPro 4.4 by EnergySoft User Number: 5670 Job Number: 06-165 Page: 11 of 13 MECHANICAL MANDATORY MEASURES Part lof 2 MECH-MM PROJECT NAME The Collection at Bressi Ranch - Building B DATE 7/2/2012 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies Any appliance for which there is a California standard established in the Appliance EfTiciency Regulations will comply with the applicable standard. Fan type central furnaces shall not have a pilot light. Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. Air handling duct systems shall be Installed and insulated in compliance with Sections 601, 602, 603, 604, and 605 of the 2001 CMC Standards. • 911 • 9< 15(a) S §«23 Controls §122(e) Each space conditioning system shall be installed with one of the following: [X] §l22(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and ail others not explicitly exempt from the requirements of Section 112 (d)) shall be Installed with an automatic time switch with an accessible manual override that allows operation of the system during off-hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss ofthe device's program and time setting for at least 10 hours if power is interrupted; or • • §l22(e)1B An occupancy sensor to control the operating period of the system; or §122(e)1 C A 4-hour timer that can be manually operated to control the operating period of the system. §l22(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint [ I §122(9) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with Isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall t>e controlled by a time control device as described above. 1X1 §l22(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within tha zone. Where used to control heating, the control shall tie adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. [X] §122(c) Thermostats shall have numeric setpoints In degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. I [ §112(b) Heat pumps shall be Installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro 4.4 by EnergySoft User Number: 5670 Job Number: 06-165 Page:12of 13 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM PROJECT NAME The Collection at Bressi Ranch - Building B DATE 7/2/2012 Description Designer Enforcement Ventilation [X] §121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. I I §122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. §122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. [X] §l21(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or I I §f^2^^|2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the Installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or I I §i21(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or I I §H2^{f)A Another method approved by the Commission. Service Water IHeating Systems • §l13(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. I [ §113(c) Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. EnergyPro 4.4 by EnergySoft User Number: 5670 Job Number: 06-165 Page:13of 13 PERFORIVIANCE CERTIFICATE OF COIVIPLIANCE (Parti Of3) PERF-1 C Project Name Date Audacity Tl 6/13/2012 Project Address 2550 Gateway Rd Ste 1 Carlsbad Climate Zone CA Climate Zone 07 Total Cond. Floor Area 3,487 Addition Floor Area 0 GENERAL INFORMATION Building Type: Nonresidential Relocatable - indicate High-Rise Residential specific climate zone Hotel/Motel Guest Room all climates Phase of Construction: New Construction Addition Alteration STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the Califomia Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author /I n ly^ark Gallant, CEPE Signature Company Gallant Energy Consulting 6/13/2012"^ Address 503 ^ Mission Ave Ste 201 Phone 760-743-5408 City/State/Zip Escondido, CA 92025 The Principal Designer hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the energy efficiency requirements contained in sections 110, 116 through 118, and 140 through 149 of Title 24, Part 6. Please check one: ENV. LTG. MECH. RECEIVED JUN 1 4 2012 diTY OF CARLSBAD EJUILDING DIVISION I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed In the State of Califomia as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licens contractor performing this work. I affirm that I am eligible under Division 3 ofthe Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. Principal Envelope Designer Name Signature Company Envelope Compliance Not In The Scope Of This Document Date Address License # City/State/Zip ^ Phone it Principal Mechanical Designer ^^'^^ Derek Irwin Signature Zjjtmk ^ ^ J fflJm Company West Air ^6^13-11 " ^ Address License # NO.820165 City/State/Zip Phone Principal Lighting Designer Name Signature Company Lighting Compliance Not In The Scope Of This Submittal Date Address License # City/State/Zip Phone INSTRUCTIONS TO APPLICANT COMPLIANCE & WORKSHEETS (check box if worksheets are included) ENV-1 C Certificate of Compliance. Required on plans. MECH-1C Certificate of Compliance. Required on plans. LTG-1 C Certificate of Compliance. Required on plans. «^ MECH-2C Air/Water Side/Service Hot Water & Pool Requirements. LTG-2C Lighting Controls Credit Worksheet ^ MECH-3C Mechanical Ventilation and Reheat LTG-3C Indoor Lighting Power Allowance. MECH-5C Mechanical Equipment Details. EnergyPro 5.1 by EnergySoft User Number: 2875 RunCode: 2012-06-13T12:45:56 ID: Page 1 of 11 PERFORMANCE CERTIFICATE OF COMPLIANCE (Part 2 Of 3) PERF-1 C project Name Dale Audacity Tl 6/13/2012 ANNUAL TDV ENERGY USE SUMMARY (kBtu/sqft-yr) Energy Component Standard Design Proposed Design Compliance Margin Energy Component Standard Design Proposed Design Compliance Margin Heating Space Heating 0 4-1 Oft 0,33 Heating Space Cooling 116.33 '0373 12.60 Cooling Indoor Fans 44.19 •fI-S2 2.37 Fans Heat Rejection O.DO 0.00 0.00 Heat Re] Pumps & Misc. O.QO O.OG 0.00 Pumps Domestic Hot Water 0 00 0 00 0.00 DHW Lighting 43.14 48.14 0.00 Lighting Receptacle fifl3f 68 31 0 00 Receptacle Process 0 00 0 00 0 00 Process Process Lighting 0.00 0 00 0.00 Process Ltg TOTALS 277.42 202 12 15.30 Percent better than Standard 5,5% { 5.5% excluding process) BUILDING COMPLIES GENERAL INFORMATION Building Orientation (S) 180 deg Conditioned FIcof Area .?497 sqft. Number of Stories 2 Urconditioned Floor Area 0 sqft. Number of Systems 2 Corxlitioned Footprint Area f /28 sqfl. Number of Zones 2 Natural Gas Available On Site t6S Orientation Gross Area Glazing Area Glazing Ratio Front Elevation (S) 540 sqft. ?96 sqft. 3.3.3% Left Elevation (Vf) 1 152 sqft. .39? sqft. 34.0% Rear Elevation IN) 540 sqfl. 147 sqft. 27.2 % Right Elevation 414 sqft. <« sqft. 9.7% Total 2 646 sqfl. sqft. 23.3 % Roof 1 759 sqft. 0 sqft. 0.0% Standard Prescriptive Lighting Power Density Prescriptive Envelope TDV Energy 0.850 i?1 037 W,'sqft. Proposed O.'ibO 177^0H Prescriptive Values for ^'^Pi^^- Comparison only See LTG-1C for allowed LPD. Remarks: THE INSTALUNS CONTRACTORS ARE RESPONSIBLE FOR THE QUANTITY AND SIZING OF HEATING. COOLING AND DHW EQUIPMENT. DUCT ^l7INn AND FOOIPMFNT ^Fl FCTION !§150(h}.r,FC B»ij/?/:.nrt/ tffiO; En/>fqfPrr> B. f .by Ene.'xiYSnft Uatir Number. 2S7S RunCoftv: 2012-06-13T12;45i56 P.?^ 2 of 11 PERFORMANCE CERTIFICATE OF COMPLIANCE (Part 3 of 3) PERF-1 C P'CjCct Name Audacity Tl Dale &13/2012 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sqft.) Inst. LPD (VV.sf)' Ctrl. Credits Altowed LPD Proc. Loads (W/sf) System Name Zone Name Occupancy Type Floor Area (sqft.) Inst. LPD (VV.sf)' Ctrl. Credits Area (W/sf)' Tailored (W/sf)'' Proc. Loads (W/sf) System 1 Is) Comp Bidg Office 1. 728 •0.S5O System 2 2nd Ca-np Bidg Office, 1. 759 •o.aso Notes-1 See LTG-to 2 Sea-TG-23 3. See LTrj-3C .sSeeLTG-tC (iten-a n^arked Ailt< asterisk, see LI01-C bv ethers) ibyolbers) UeTis 3bow 'e>quire specs! documenlaooi EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The kkcal enforcement agency should pay special attention to the items specified in this checklist. These items require special written Justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justifications, and may reject a building or design that otherwise complies based on the adequacy of the special justiflaatlon and documentation submitted. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justilicalion and documentation for their use have been provided tiy the applicant. Authoil^eU Siiinatuie or Stamp E.norgyP.-o 5.1 ty EnergySoft User Nc/vbor 2B75 RunCode: 2012-06-13712:45:56 ID: Pago 3 of 11 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 1 Of 4) MECH-1C Pra.ect Name Audacity Tl Dale 6/13/2012 ProsflCS AfSdrfiss 2550 Gateway Rd Ste 1 Carlsbad Climate Zens Total Cond Floar Area 3.487 Addition Floor Area 0 GENERAL INFORMATION Building Type: Nonresidential High-Rise Residential Hotel/Motel Guest Room Scl'ools (Putlic School) Relocatable Public SchocI BIdg. Conditioned Spaces Unconditioned Spaces (affidavit) Phase of Construction. New Construction Addition Alteration Approach cf Compliance: Component Overall Ervelopa TDV Energy Unconditioned (file affidavit) Front OricntaliDn: N, E. S, W or in Degrees: 100 deg HVAC SYSTEM DETAILS FIELD INSPECTION ENERGY CHECKLIST Equipment' Inspection Criteria Meets Criteria or Requirements Equipment' Inspection Criteria Pass Fall - Describe Reason' Item or System Tags (ifi AC-1 RTU-1,HP-1) Sysferr? 1 Equipment Type': Packaged DX Number of Systems 1 Max Allowed Heating Capacity 56.000 Btu/hr Minimum Healinq Efficiency' 7.70 HSPF Max Allowed Cooling Capacity' 57.200 Btu/hr Onnliog Fffiaf»nr.y' 13.0 SEER/11.0 EER Duct Location^ R-Value Attic, Ceiling Ins. vented/B.O (Alien duct testing is requirec, submit MECH-4A & MECH-4-HERS No Economizer No Economizer Thermo5t3t Setback Required Fan Control Constant Volume Equipment' Inspection Criteria FIELD INSPECTION ENERGY CHECKLIST Equipment' Inspection Criteria Pass Fail - Describe Reason* Hem or System Tags (i.e.AC-1 RTU-1,HP-1) Systam 2 Equipment Type': Packaged DX NumDer of Systems 1 Max Allowed Heating Capacity' 56,000 Btu/hr Mlrimurn Heatinq Effiaen-oy' 7.70 HSPF Max .Allowed Cooling Capacity' 57.200 Btu/fir Cnolinrj FfTiftiftncy' 13.0 SEER/ n.OEER Duct Location/ R-Val uo Attic, Ceiling Ins. vented / 8.0 'A'tien duct testing is required, submit MECH-4A & MECH-4-HERS No Economize'' No Economizer Thermostat Setback Required Fan Control Constant Volume 1. If the Acsual >ns;aile<l equipinenl ^'edormarice etTiclency and capacity is less than the Proposed (from the energy oomopharice submittal or froir the building plans) Ihe rasocflsiblo party shall resubmit energy cofnpfiance lo indude lha .IB'A' changes. 2 For fidciitional detailed discrepancy use Page 2 of ttie Inspection Checklist Form Comolianr-e fails if a Fail box is cneciied 3 Indicate Eriuipment Type: 3as (Pkg or. Split). VAV. HP iPkg or split). Hydronir: PTAC. or other. EiieryyPio 5.) by tiiCfjjySo;.' User Numboi. 2B/5 RunCode: 2012-06-13712:45:56 ID: Hitae4Dl 11 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 2 of 4) MECH-1C Pmeci Name Audacity Tl Dale 6/13/2012 Discrepancies: E.-?flrgvPro 5.! by E.nerqySoft User Nurrbsr: 2875 , RonCorfe: 2012-06-13712:45:56 ID. Page 5af11 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 3 of 4) MECH-1C Audacity Tl &'iy2012 Required Acceptance Tests Designer: Tli^ ram lo used by Ihe designer and anactied to the plans. List«d beicw are all the acceptance lesis lor n-echarical s>-sten». The designer Is re<|ulred to check Ihe ^plicatile ^uxes by lit act>epCd;ic-e te:^ls that aptily and listtKi aa equipf ne-it tt'BJi rc^quires an aci^eplaiKe '.est tf al tKtuipirent -jt e certain type requires a tesl. hst ttte equipmei^t desonp!iczr^ ard till- nuiiilTe' Lit sy;%lenis. Tfwi NA nijiritjer ilssigiiiillis ;hR SB£:U»I i:: ItiK A|j:>t?ridix iif tlie N(HitK»iiJiiiili:il R«fnreTK»; AfifiKKiitirM M;sriial :h:»l iles<:riijc*; Itw lest Sric« IJiis fcrni will t:tt Bart Df Ihe plans, rompteUoo of fs section 'iv4 ESCIW ttie r«s|»is»09 party lo budge! t3r ina scope of v«ofk aporopnatBl'/, Building Departments: SysleifM Acccpt4AC»: G<^1:^r^^ iw:aipan::y pftfnil i-; <jraitteit loi a rmwly o:«'i.tlfu::t«tl :>.iiidiivj tir s;vicft, nrw,! NWiCft '-Or>ttilKJiung Systuri serving a buikting or space i$ 0(»eral<Hl tor normat U5e. ail control devices s^-^^lf^ ttie txiikJiniS or spaos stiali be certified as neeting 11^ Acceptance Ro^uinements f-2«r Code Ccrpfliance Syxlemi Acceptance: Beiaift (i(3ai[ianf.y fiefnil i< ijranleil All rewr^y inslaJed l-IVAC «iH.ipiMnl nusl lie tested iising Itie Acnepiatice RequiraTieftts rtie MECt^-^C tcrni is n<3l ocMiadcfed a completBd ^orrn and i±f not to be aoi-es>tet3 by ihe t)uildir>3 detwirtTiefirt onless Ihe -ortecl l<ixBi are iliectied. Tiie equicmeiil raqurfrig tea'.trKj. aerson perttym-iq ihe test lErample: H'JAC i,istaller, TAB conlra::taf, controls conracto'. PE In cfiarge of prciecti and 'n'hal A:ceptance test n'tist 3« cortdLCted. The fcllowinq chackad-olf fomis are reti^rBd 'ot ALL lewy installed equipmenl in adation a Lertilicate ol Acceptarce lorms i.'^all &9 submitted to Ihe Duildinj departner* ihEt celilies plans, 5|>s<:ifii-;iticfn, nsl^llalinn, cettiBcalss .)iid iipersliiiii and ni,-iinleiiam:is info rratinn ineel IHe renuiiKmenus of §in.10J(i)t «id T^lt^?'S Pari 6 The buiklng vistwclrir mu-il rtsceivis 'he pmpRry rllleKt r*i1 anrl Kvyiori fnrm!: rwSr«: Iho tHiil.'iiivj rjin mr^vo final rmipafifTy TEST DESCRIPTION MFCH-7A MFr,H-3A r.*F;;H-i4 i/SfCH-ra MECH-W MFCH-H* : t*cn-i5A MFCH-11A OiMoor FLT •.•A'J S Cs'.' '•\tlutr e 4 3iiiiiJe-2i.lv A/1 Di:])i'.iuliL«i Cu'i(i:;i» DeTsnil Cullrul Verilikiliui OCV Fd„ VAV Vfc*>/e Leal'aye Teal Suppy 'AV:«i Tyirip Mydrnnc VwiaLfe Aul«na«: Cr*ii a^iL SlifJ C-;^! HI.-' Oiar l\'u.t:tv.'. 2S7S Page 6 iV 11 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 4 of 4) MECH-1C ^•rc^oct Njire Da.** Aiidaot/ r\ 6/13/2012 rest DESCRIPTION MCCt* • hqiiipnwrt KfiqwriKi IflA'irv} FduH Ajti>n»jc Fault Ostrisuetl ror IJX I.nt?-, AiDt/rrw Sy^tens Tteniisl Erwrgv i' InstaHing Contractcr AIR SYSTEM REQUIREMENTS (Part 1 of 2) MECH-2C PfD(Qcl Name? Date Audacity Tl 6/13/2012 Item or System Tags (i.B.AC-1, RTU-1. hP-1) Indicate Air Systems Type (Central, Single Zone. PacKag e, VAV, or etc..) Item or System Tags (i.B.AC-1, RTU-1. hP-1) Sysferr? 1 System 2 Numtjer of Systems 1 1 Indicate Pa ge Reference on Plans or Schedule and Indicate the applicable exception(s) MANDATORY MEASURES HBatif*? fcquipmant trticiency Cooling Equipment Efficiency HVAC Heal Pump Th«rmt>slat Furnace Contfolsi'Thermoslat Nat.jral Vent!!,itior Mechiiriicdi VuiiUlalkxi VA^i' Mininnum Position Cootml Demand Control Ventilation Time Control Setback and Setua Contn-jl Outdoor Oarnpe' Control Isolation Zones Ppo Insulatiori Duel -ocalion/ R-»aliie T-24 Sections MANDATORY MEASURES HBatif*? fcquipmant trticiency Cooling Equipment Efficiency HVAC Heal Pump Th«rmt>slat Furnace Contfolsi'Thermoslat Nat.jral Vent!!,itior Mechiiriicdi VuiiUlalkxi VA^i' Mininnum Position Cootml Demand Control Ventilation Time Control Setback and Setua Contn-jl Outdoor Oarnpe' Control Isolation Zones Ppo Insulatiori Duel -ocalion/ R-»aliie ii:;(a) rroHSpr rroi'SPr MANDATORY MEASURES HBatif*? fcquipmant trticiency Cooling Equipment Efficiency HVAC Heal Pump Th«rmt>slat Furnace Contfolsi'Thermoslat Nat.jral Vent!!,itior Mechiiriicdi VuiiUlalkxi VA^i' Mininnum Position Cootml Demand Control Ventilation Time Control Setback and Setua Contn-jl Outdoor Oarnpe' Control Isolation Zones Ppo Insulatiori Duel -ocalion/ R-»aliie 1)2(3) 13 0 SEER/11,0 EER 13 0 SEER/ 17.0EER MANDATORY MEASURES HBatif*? fcquipmant trticiency Cooling Equipment Efficiency HVAC Heal Pump Th«rmt>slat Furnace Contfolsi'Thermoslat Nat.jral Vent!!,itior Mechiiriicdi VuiiUlalkxi VA^i' Mininnum Position Cootml Demand Control Ventilation Time Control Setback and Setua Contn-jl Outdoor Oarnpe' Control Isolation Zones Ppo Insulatiori Duel -ocalion/ R-»aliie 112(b), -12(c) Ve.-i Yes MANDATORY MEASURES HBatif*? fcquipmant trticiency Cooling Equipment Efficiency HVAC Heal Pump Th«rmt>slat Furnace Contfolsi'Thermoslat Nat.jral Vent!!,itior Mechiiriicdi VuiiUlalkxi VA^i' Mininnum Position Cootml Demand Control Ventilation Time Control Setback and Setua Contn-jl Outdoor Oarnpe' Control Isolation Zones Ppo Insulatiori Duel -ocalion/ R-»aliie 112{c| 115(a| r/a ft/a MANDATORY MEASURES HBatif*? fcquipmant trticiency Cooling Equipment Efficiency HVAC Heal Pump Th«rmt>slat Furnace Contfolsi'Thermoslat Nat.jral Vent!!,itior Mechiiriicdi VuiiUlalkxi VA^i' Mininnum Position Cootml Demand Control Ventilation Time Control Setback and Setua Contn-jl Outdoor Oarnpe' Control Isolation Zones Ppo Insulatiori Duel -ocalion/ R-»aliie 121(D) JVC Wo MANDATORY MEASURES HBatif*? fcquipmant trticiency Cooling Equipment Efficiency HVAC Heal Pump Th«rmt>slat Furnace Contfolsi'Thermoslat Nat.jral Vent!!,itior Mechiiriicdi VuiiUlalkxi VA^i' Mininnum Position Cootml Demand Control Ventilation Time Control Setback and Setua Contn-jl Outdoor Oarnpe' Control Isolation Zones Ppo Insulatiori Duel -ocalion/ R-»aliie IZI('J) 2o<J dn 264 cO» MANDATORY MEASURES HBatif*? fcquipmant trticiency Cooling Equipment Efficiency HVAC Heal Pump Th«rmt>slat Furnace Contfolsi'Thermoslat Nat.jral Vent!!,itior Mechiiriicdi VuiiUlalkxi VA^i' Mininnum Position Cootml Demand Control Ventilation Time Control Setback and Setua Contn-jl Outdoor Oarnpe' Control Isolation Zones Ppo Insulatiori Duel -ocalion/ R-»aliie 121(c) No MANDATORY MEASURES HBatif*? fcquipmant trticiency Cooling Equipment Efficiency HVAC Heal Pump Th«rmt>slat Furnace Contfolsi'Thermoslat Nat.jral Vent!!,itior Mechiiriicdi VuiiUlalkxi VA^i' Mininnum Position Cootml Demand Control Ventilation Time Control Setback and Setua Contn-jl Outdoor Oarnpe' Control Isolation Zones Ppo Insulatiori Duel -ocalion/ R-»aliie 121(:) Nc iVO MANDATORY MEASURES HBatif*? fcquipmant trticiency Cooling Equipment Efficiency HVAC Heal Pump Th«rmt>slat Furnace Contfolsi'Thermoslat Nat.jral Vent!!,itior Mechiiriicdi VuiiUlalkxi VA^i' Mininnum Position Cootml Demand Control Ventilation Time Control Setback and Setua Contn-jl Outdoor Oarnpe' Control Isolation Zones Ppo Insulatiori Duel -ocalion/ R-»aliie 122(3) Prcgrammatite Switcn Prvgrsmmable Switch MANDATORY MEASURES HBatif*? fcquipmant trticiency Cooling Equipment Efficiency HVAC Heal Pump Th«rmt>slat Furnace Contfolsi'Thermoslat Nat.jral Vent!!,itior Mechiiriicdi VuiiUlalkxi VA^i' Mininnum Position Cootml Demand Control Ventilation Time Control Setback and Setua Contn-jl Outdoor Oarnpe' Control Isolation Zones Ppo Insulatiori Duel -ocalion/ R-»aliie 1220) ^;bi!Ck Koi;ui,'9d SelbacM Rmiuimd MANDATORY MEASURES HBatif*? fcquipmant trticiency Cooling Equipment Efficiency HVAC Heal Pump Th«rmt>slat Furnace Contfolsi'Thermoslat Nat.jral Vent!!,itior Mechiiriicdi VuiiUlalkxi VA^i' Mininnum Position Cootml Demand Control Ventilation Time Control Setback and Setua Contn-jl Outdoor Oarnpe' Control Isolation Zones Ppo Insulatiori Duel -ocalion/ R-»aliie 122(0 Ajto Auto MANDATORY MEASURES HBatif*? fcquipmant trticiency Cooling Equipment Efficiency HVAC Heal Pump Th«rmt>slat Furnace Contfolsi'Thermoslat Nat.jral Vent!!,itior Mechiiriicdi VuiiUlalkxi VA^i' Mininnum Position Cootml Demand Control Ventilation Time Control Setback and Setua Contn-jl Outdoor Oarnpe' Control Isolation Zones Ppo Insulatiori Duel -ocalion/ R-»aliie 122(3) <\.'& MANDATORY MEASURES HBatif*? fcquipmant trticiency Cooling Equipment Efficiency HVAC Heal Pump Th«rmt>slat Furnace Contfolsi'Thermoslat Nat.jral Vent!!,itior Mechiiriicdi VuiiUlalkxi VA^i' Mininnum Position Cootml Demand Control Ventilation Time Control Setback and Setua Contn-jl Outdoor Oarnpe' Control Isolation Zones Ppo Insulatiori Duel -ocalion/ R-»aliie 123 MANDATORY MEASURES HBatif*? fcquipmant trticiency Cooling Equipment Efficiency HVAC Heal Pump Th«rmt>slat Furnace Contfolsi'Thermoslat Nat.jral Vent!!,itior Mechiiriicdi VuiiUlalkxi VA^i' Mininnum Position Cootml Demand Control Ventilation Time Control Setback and Setua Contn-jl Outdoor Oarnpe' Control Isolation Zones Ppo Insulatiori Duel -ocalion/ R-»aliie 124 /Wic Coiling f.n.?, i^ented / S O Attic Celling ln;x verted/B.O PRESCRIPTIVE MEASURES CalcuUil^ Dtjsign Hef^Uny L j^fd Prooosad Heating Capacity Calculated Design Cooling Lr>ad ProQfKed Cnoling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DOC only) Simultaneous Heat'Cool Ecdi'On.iifi! Heat Air Supply Reset Cool Air Supply Reset Electric ResisUmce tH^jiitirig' A* Coded Ctiiller Liniitatk5n Duct ^.eakagc Soaliog if Yt-s, a MECH-4-A must tie sut^ilted 144(a S bl r.-'a n/a CalcuUil^ Dtjsign Hef^Uny L j^fd Prooosad Heating Capacity Calculated Design Cooling Lr>ad ProQfKed Cnoling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DOC only) Simultaneous Heat'Cool Ecdi'On.iifi! Heat Air Supply Reset Cool Air Supply Reset Electric ResisUmce tH^jiitirig' A* Coded Ctiiller Liniitatk5n Duct ^.eakagc Soaliog if Yt-s, a MECH-4-A must tie sut^ilted 144(a &D( 42.039 fliu/Jir 42.S39Bii)fhi CalcuUil^ Dtjsign Hef^Uny L j^fd Prooosad Heating Capacity Calculated Design Cooling Lr>ad ProQfKed Cnoling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DOC only) Simultaneous Heat'Cool Ecdi'On.iifi! Heat Air Supply Reset Cool Air Supply Reset Electric ResisUmce tH^jiitirig' A* Coded Ctiiller Liniitatk5n Duct ^.eakagc Soaliog if Yt-s, a MECH-4-A must tie sut^ilted 144(.-J&bl /va :!/-j CalcuUil^ Dtjsign Hef^Uny L j^fd Prooosad Heating Capacity Calculated Design Cooling Lr>ad ProQfKed Cnoling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DOC only) Simultaneous Heat'Cool Ecdi'On.iifi! Heat Air Supply Reset Cool Air Supply Reset Electric ResisUmce tH^jiitirig' A* Coded Ctiiller Liniitatk5n Duct ^.eakagc Soaliog if Yt-s, a MECH-4-A must tie sut^ilted 144(a & til -15.70S Slu.'hr 45.3S5 Btu/hr CalcuUil^ Dtjsign Hef^Uny L j^fd Prooosad Heating Capacity Calculated Design Cooling Lr>ad ProQfKed Cnoling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DOC only) Simultaneous Heat'Cool Ecdi'On.iifi! Heat Air Supply Reset Cool Air Supply Reset Electric ResisUmce tH^jiitirig' A* Coded Ctiiller Liniitatk5n Duct ^.eakagc Soaliog if Yt-s, a MECH-4-A must tie sut^ilted 144(c) Cc/i.5'a."f Volume Con.s.'anf Volume CalcuUil^ Dtjsign Hef^Uny L j^fd Prooosad Heating Capacity Calculated Design Cooling Lr>ad ProQfKed Cnoling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DOC only) Simultaneous Heat'Cool Ecdi'On.iifi! Heat Air Supply Reset Cool Air Supply Reset Electric ResisUmce tH^jiitirig' A* Coded Ctiiller Liniitatk5n Duct ^.eakagc Soaliog if Yt-s, a MECH-4-A must tie sut^ilted 144(C) CalcuUil^ Dtjsign Hef^Uny L j^fd Prooosad Heating Capacity Calculated Design Cooling Lr>ad ProQfKed Cnoling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DOC only) Simultaneous Heat'Cool Ecdi'On.iifi! Heat Air Supply Reset Cool Air Supply Reset Electric ResisUmce tH^jiitirig' A* Coded Ctiiller Liniitatk5n Duct ^.eakagc Soaliog if Yt-s, a MECH-4-A must tie sut^ilted 144(,-) Yes /e.'i CalcuUil^ Dtjsign Hef^Uny L j^fd Prooosad Heating Capacity Calculated Design Cooling Lr>ad ProQfKed Cnoling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DOC only) Simultaneous Heat'Cool Ecdi'On.iifi! Heat Air Supply Reset Cool Air Supply Reset Electric ResisUmce tH^jiitirig' A* Coded Ctiiller Liniitatk5n Duct ^.eakagc Soaliog if Yt-s, a MECH-4-A must tie sut^ilted 144(d) No No CalcuUil^ Dtjsign Hef^Uny L j^fd Prooosad Heating Capacity Calculated Design Cooling Lr>ad ProQfKed Cnoling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DOC only) Simultaneous Heat'Cool Ecdi'On.iifi! Heat Air Supply Reset Cool Air Supply Reset Electric ResisUmce tH^jiitirig' A* Coded Ctiiller Liniitatk5n Duct ^.eakagc Soaliog if Yt-s, a MECH-4-A must tie sut^ilted 144(e) No F.-rononi/rsr No Economi7°r CalcuUil^ Dtjsign Hef^Uny L j^fd Prooosad Heating Capacity Calculated Design Cooling Lr>ad ProQfKed Cnoling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DOC only) Simultaneous Heat'Cool Ecdi'On.iifi! Heat Air Supply Reset Cool Air Supply Reset Electric ResisUmce tH^jiitirig' A* Coded Ctiiller Liniitatk5n Duct ^.eakagc Soaliog if Yt-s, a MECH-4-A must tie sut^ilted 144(f) Co^^^tar,t Tejnp CalcuUil^ Dtjsign Hef^Uny L j^fd Prooosad Heating Capacity Calculated Design Cooling Lr>ad ProQfKed Cnoling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DOC only) Simultaneous Heat'Cool Ecdi'On.iifi! Heat Air Supply Reset Cool Air Supply Reset Electric ResisUmce tH^jiitirig' A* Coded Ctiiller Liniitatk5n Duct ^.eakagc Soaliog if Yt-s, a MECH-4-A must tie sut^ilted 144(f) CQn.';?3ni Temp Cnnsiar.t Tamp CalcuUil^ Dtjsign Hef^Uny L j^fd Prooosad Heating Capacity Calculated Design Cooling Lr>ad ProQfKed Cnoling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DOC only) Simultaneous Heat'Cool Ecdi'On.iifi! Heat Air Supply Reset Cool Air Supply Reset Electric ResisUmce tH^jiitirig' A* Coded Ctiiller Liniitatk5n Duct ^.eakagc Soaliog if Yt-s, a MECH-4-A must tie sut^ilted 144(.j) CalcuUil^ Dtjsign Hef^Uny L j^fd Prooosad Heating Capacity Calculated Design Cooling Lr>ad ProQfKed Cnoling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DOC only) Simultaneous Heat'Cool Ecdi'On.iifi! Heat Air Supply Reset Cool Air Supply Reset Electric ResisUmce tH^jiitirig' A* Coded Ctiiller Liniitatk5n Duct ^.eakagc Soaliog if Yt-s, a MECH-4-A must tie sut^ilted 1440 CalcuUil^ Dtjsign Hef^Uny L j^fd Prooosad Heating Capacity Calculated Design Cooling Lr>ad ProQfKed Cnoling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DOC only) Simultaneous Heat'Cool Ecdi'On.iifi! Heat Air Supply Reset Cool Air Supply Reset Electric ResisUmce tH^jiitirig' A* Coded Ctiiller Liniitatk5n Duct ^.eakagc Soaliog if Yt-s, a MECH-4-A must tie sut^ilted 144K) Wo No 1. Total installed capacity (f/Btui'hr) of all e4ec1ric heat on this project 8xc1usii.a of electric auxiliary heat for heat pumps. If aleclric heat is used expla^i wliicti tjjiceptnjti(s) \o §''t4i;y | apsjiy E.ne.'-gyP.-o 5 J ty EnsrgySDft User Number: 2875 RunCode: 2012-06-13712:45:56 ID: Paae 8 of 11 MECHANICAL VENTILATION AND REHEAT MECH-3C Audxity 71 Oale 6.^13/2012 MECHANICAL VENTILATION |^121lbi2) REHEAT LIMITATION (5144(d|) «fl£A BASIS UCUUPANCT BASIS VAV MINIMUM A a c • E F a M 1 J K L H N Zane^OysleRi AfSJ lit') I- MmCfM Ry Aflf:,! ox C Nur-oer Ol Pcosle Peracn Mn Cf M oy Otr.t-.i.p4r< i:xr HZ.UL VA. \U, .11 Dor G Oeugn VerrbLabco Air CTM •jLfi. al Design Zone Simply CTM BXC-4 CfM.' It' r.1a«. ol Coljinra H. J. K. XXI crM Oesgn Al Setpomt Trar.-vVir tsl t.ris 7 5 259 2S9 259 rb'ai t.,'56 0 1 i reus Co uirn 1 TDUI Oe&gn .Ar t: lAiiiTiuin ^-er.oliilim rals pef SettL^i ^^i::!, Ijtic Ii!l A. f HfiM«1 :y\ nxittf iAAt cit •.tin .y^nt^ ' pl tr* ^^(H*i.if4i ntint^ti.-it ivj>ipfl.,tn r/thflCBC rr^jipflfTit lrt*1 ^v AC)rA><fi ;u.fpfiJ;*kft tiy Ar*4rMfl ^miH.I n)i*ii1ftj^sr.r*i II Ro^urnrt *.iftnliUlirn Ar iRFQn '»' A l K Ihn .^rqcr nf Tifi wililatinn Mirs rari.i.i1(tn nn APFA ftASiS nr OCCUPANCY BASIS (i.>.Uir/i D 0) 1 lAjst Ce ^reol^sr tttari ur c>^u:!l lu h, c< Lse Trars^r Air (COL nvi;;»9n ^u.ifJv CFM rF.^ft CFUl x ^OH. f.i lU* i^^fj'i 7-: rnn fi| to rr*e UD ll-e Jitlcfmoe. J lAjst Ce ^reol^sr tttari ur c>^u:!l lu h, c< Lse Trars^r Air (COL nvi;;»9n ^u.ifJv CFM rF.^ft CFUl x ^OH. f.i lU* i^^fj'i 7-: K Coticitjixi area l¥t x 3 4 Cft.! .• ly. L lAjKmiir. r.1 CriijTirA H, .1 .VI."; CFt.1 M Tnti T*ji: tc CSS Ihin equal t] C-lumti L anrj qroalo- tnan Dr nqjal lo Iho tjrri ol Cclumna H F4L^ M. N rra(i;.'flr ,^.T rr»j3l t« [;ru'/i;)ed ^liere .^m ^e-^ui^ej V'i?itialtjn Air |C:;lurt» ' I.l »'jriMrle- •.'isf- I'le C*f^Jgii r.Vr,rijum Ac iCukjifn Ml. '/i^trefC requcod. Irnnslur uir rru?;. I'e jrwiter '.rtsn 'jf tff^jtfl If-i lti.5 JilftfWl^s t>tflw«r!n ll-« n«:juir(;d 'jVi-iijlslir..*! AT iCofc.irnn iM vJ i~in^i:]fi Vi'-p'njrr ^jr iCi limn Vii Culjn-n M rrirn.:5 \t Fniw^jV^ .1 J flf F';i;>i7/.'i.iil lAia-.'ji.mncv-J'sr.-j KunCtxH. 2012-)t-1}Tl i 45.i6 lO P.i,jn nf MECHANICAL EQUIPMENT DETAILS (Part 1 of 2) MECH-SC pp-qoct Naire AiidaciP/ 71 Dale &'1X/2012 CHILLER AND TOWER SUMMAftY PtIMPS Eouiprneflil Nime Type 1 EfFicicficy | Tons «»: GPM BHP Pimtp Control 1- DHW/BOILER SUMMARY Svilem Name T|fl» Dislribullon Qtt. Rated Incol Vol. rOaHI. Energy Fadoi wRE standby L084 ot Pilot Taok EMI R-Value Staitua MULTI-FAMILY CENTRAL WATER HEATING DetAILS Hot Wator Pump Hot W^r Piping Lanalh i1t) Control HP In PIfliium OutskM Burwd Add '.-V Insulaton CENTRAL SYSTEM RATINGS HEATIMG COOLING Sytitam HAtmk typ* 0<ji|Mj< Au>. kW ErTiciancy OullRlt EfticlAncy status ^'a-Jtii,-™ UX Ll j •'- lil HS.(.f :.io iLCR.- r L ilti* '.t-w CENTRAL SYSTEM FAN SUMMARY SUPPLY FAN RETURN FAN F*rt Typ* EwAomlHr 1VP« CFM BHP CFM BHP No Ecaxmaer 2,0(10 ars 5-'.'^i jvi'-'r.i ? r Of-£'ierav5o'i /"•3« ro .Jcr') MECHANICAL MANDATORY MEASURES: NONRESIDENTIAL MECH-MM Project Name Date Audacity Tl 6/13/2012 Equipment and System Efficiencies §111: Any appliance for vvtiicti there is a California standard estabsistied in tha Appliance Efficiency Regulations will comply M\h the applicable standsrd. §115(a); Fan type central furnaces shall not rtavo a pilot light §123: piping, except that conveying lluids at temperatures bel'iveen 60 and 105 degrees Fahrenheit, or wiihin HVAC equipment, shall be insulated in accordance witti Standards Section 123. §124: Air handing rtirt systems shall be installed anrl insulated m mrrplianc« wilti Sflctions fiOl, 302, fiO.3, fin4. anrf fiOS of the CMC Slandards Controls §1?2(e): Fach space conditioning system shall be installed with rnw nf the Fnlfowmg: 1A. Each space conditioning system serving building types such as ofTices and manufacturing facilities (and all others not axplici'.ly exempt from Ihe requirements of Section '12 (d)) shall be insiaJled with an automatic lime switch '.vith an accessible manual override that allows operation ofthe system during off-hours for jp to 4 hours. The time s'Afitch stiall tie capable of prcgramming differtjnt st;hedules for v^eakdays and weekends and have program backup capabilities that prevent tha loss of the device's program and time setting for at least 10 hours if power is interrupted: or IB. An occupancy sensor to control the cperating period of the system: or 10. A4-hour timer that car be manually operatec to control Ihe operating pieriocl of the system. 2. Each spar^ conditioning system shall be installed lAiith contrcts that temporarily restart and terrporarily operate the system as tequiied to malniain a ssetbacii healing and,'or a stjtup cooling themtostat setpoint. Each space conditioning system serving multiple zones 'Anth a combined condrtione-;1 floor area more tt^an 25,030 §122(9): sqLare feet shall be provided with tsclation zones. Each zone: shall not exceed 25.000 square teel; shall be prcvded iwith isolation cevices, such as valves or dampers that allow the supply of heating or cooiing to be setback or shut off independently o( other isolation areas; and sfvsll tie controlled by a time control devce as described above. §122(C): Thermostats shall have numeric setpoints m degrees Fahrenheit (F| and adjustable setpoint stops accessltiie coiy to authorized personnel. §122(b); Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone §122(a&b): Each space conditioning system stiall be controlled by an Irdividual thermostat that responds to temperature within the zore. Where used to control heating, the control shall be adjustable dov/n to 55 degrees F or lower For cooling, the cot-trol shall be adjustable up to 85 degrees F or higt er. Where used for both heating and cooling. Itie oontnDl stiall be ciapable of providing a deadtiand of at least 5 degrees F within which the supply o' healing and cc»ling is sl ut off or reduced to a minimum. Ventilation §121(«). Controls stiail oe proi/ided to allow outside air dampers or devices to be operated at the ventiialior ra'.es as specified on these plans. § 122(0: Al gravity ventilating systems shall be provided with automatic or readiy accessible manuaily operated carnpers in ah openings to the outside, except 'or combustion air openings §121(f): Ventilation System Acceptance. Before an occupancy permit is grantee for a newty constructed buHding or space, or a new ventilating system serving a bi.il<iing or space is operate:! for normal use. all ventilation systems serving the building or space shall be csflifiec as meeting ltie Acceptance Requiren-ients (or Code Compliance Service Water Heating Systems §113(0 Installation 3. Temperature cmitrcls far public la'jatories. The controls shall ilrTiit the actlat Teinparalura to 110' F. 2. Circulating service 'A»ater-heaiing systems stiall have a control capable of automatically turning off Uie circulating pump when hot water s not required Fr.e.-gyPro Ci.l hy Ene.^gySaft U.-ier N(Jint>er 2fi7rt RunCode: 2012-00-13712:45:56 ID: Piige 1' r.ni SEP-06-2007 THU 03:16 PM CITY OF CARSLBAD FAX NO. 760 602 8558 P. 20 COMMUNITY FACILITIES DISTRICT NO. 1 NON-RESIDENTIAL CERTIFICATE NON-RESIDENTIAL LAND OWNER, PLEASE READ THIS OPTION CAREFULJ_Y AND BE SURE YOU THOROUGHLY UNDERSTAND BEFORE SIGNING THE OPTION YOU <;H0SE WILL AFFECT YOUR PAYMENT OF THE DEVELOPED SPECIAL TAX ASSESSIID ON YOUR PROPERTY THIS OPTION IS AVAILABLE ONLY AT THE TIME Of THE FIRST BUILDING PERMIT ISSUANCE PROPERTY OWNER SIGNATURE IS REQUIRED BEFORE SIGNING YOUR SIGNATURE IS CONFIRMING THE ACCURACY OF ALL INFORMATION SHOWN BRESSI OCEAN COLLECTION LLC 714638-7277 NAIVIEOF OWNER TELEPHONE 1280 BISON B9-609 2SS0 GATEWAY RD BLD D (& 2352,2554,2456 GATEWAY) ADDRESS PROJECT ADDRESS NEWPORT BEACH CA 92660 CARLSBAD, CA 92009 CITY. STATE ZIP CITY. STATE ZIP 213 261 09 00 LOT 18 ASSESSOR PARCEL NUMBER(S) OR APNCS) AND LOT NUIVIBEHSCS) IF NOT YET SUBDIVIDED BY COUNTY ASSESSOR CB070434 BUILDING PERMIT NUMBERCS) As CITED BY ORDINANCE NO NS-1 55 AND ADOPTED BY THE CITY OF CARLSBAD, CALIFORNIA, THE CITY IS AUTHORIZED TO LEVY A SPECIAL TAX IN COMIVIUNITY FACILITIES DISTRICT NO l ALL NON-RESIDENTIAL PROPERTY. UPON THE UiSUAt^CE OF A BUILDING PERMrT, SHALL HAVE THE OPTION TQ (1) PAY THE SPECIAL DEiVELOPMENT TAX ONE TIME OR (2) ASSUME THE ANNUAL SPEICIAL TAX - DEVELOPED PROPERTY FOR A PERIOD NOT TO EXCEED TWENTY- FIVE (25) YEARS PLEASE INDICATE YOUR CHOICE BY INITIALIZING THE APPROPRIATE LINE BELOW OPTION (1) I ELECT TO PAY THE SPECIAL TAX - ONETIME NOW. AS A ONE-TIME PAYMENT AMOUNT OF ONE-TIME SPECIAL TAX: $ 13,236.12 OWNER'S INITIALS OPTION (2) 1 ELECT TO PAY THE SPECIAL DEVELOPMENT TAX ANNUALLY FOR A PERIOD NOT TO EXCEED TWENTY-FIVE (25) YEAFJS MAXIMUM ANNUAL SPECIAL TAX' $ 1,827.91 OWNER'S INITIAL I DO HEREBY CERTIFY UNDER PENAL1Y OF PERJURY THAT THE UNDERSIGNED IS THE PROPERTY OWNER OF THE SUBJECT PROPERTY AND THAT 1 UNDERSTAND AND WILL COMPLY WITH THE PROVISION AS STATED ABOVE, TITLE PRINT NAME DATE THE Crrv OF CARLSBAD HAS NOT INDEPENDENTLY VERIFIED THE INFORMATION SHOWN ABOVE THEREFORE, WE ACCEPT NO RESPONSIBILmr AS TO THE ACCURACY OR COMPL^ENESS OF THIS INFQRI^ATION LAND USE, FY. FACTORINDUS 3/03 .8624 X SQUARE FT \ 5.348= 13,236.12 INDUSTRIAL WASTEWATER DISCHARGE PERMIT ^11 SCREENING SURVEY Date^/W/f^ . , - Business Name frUCjCC C-cZZl Street Address ^^^TZ) ^:^^:;^;>fe^(^r^y/^^^ Efnail Address '_ PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) Check all below that are present at your facility: Acid Cleaning Ink Manufacturing Nutritional Supplement/ Assembly Laboratory Vitamin Manufacturing Automotive Repair Machining / Milling Painting/Finishing Battery Manufacturing Manufacturing Paint Manufacturing Biofuel Manufacturing Membrane Manufacturing Personal Care Products Biotech Laboratory (i.e. water filter membranes) Manufacturing Bull< Chemical Storage Metal Casting / Forming Pesticide Manufacturing / Car Wash Metal Fabrication Packaging Chemical Manufacturing Metal Finishing Pharmaceutical Manufacturing Chemical Purification Electroplating (including precursors) Dry Cleaning Electroless plating Porcelain Enameling Electrical Component Anodizing Power Generation Manufacturing Coating (i.e. phosphating) Print Shop Fertilizer Manufacturing Chemical Etching / Milling Research and Development Film/X-ray Processing Printed Circuit Board Rubber Manufacturing Food Processing Manufacturing Semiconductor Manufacturing Glass Manufacturing Metal Powders Forming Soap / Detergent Manufacturing Industrial Laundry Waste Treatment / Storage SIC Code(s) (if known): Brief description of business activities (Production / Manufacturing Operations):, Description of operations generating wastewater (discharged to sewer, hauled or evaporated): Estimated volume of industrial wastewater to be discharged (gal / day): List hazardous wastes generated (type / volume): / Date operation began/or will begin at this location: Have you a|5plied ftir a Wastewater Discharge Permit from the Encina Wastewater Authority? Yes Ul^lO'^ If yes, when: Site Contact Signature ENCINA WASTEWA;C£R'AUTHDRITY, 6200 Avenida Encinas Carlsbad, GA 92011 (760)438-3941 FAX: (760)476-9852 SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# HV# BP DATE / / Business Name , - A Business Contact <^.^/LM TeleBticipe # / ^ APN# Mailing Address _ • ^ / City y / State^ Zip Code ^ Plan File# Project Contact i'--- , , . —^ / ' C' Telephone # ' The following questions represent the facility's activities, NOT the specific project description. PART 1: FIRE DEPARTMENT - HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate bv circlina the item, whether vour business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Facility's Square Footage (including proposed project): Occupancy Rating: 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives 2. Compressed Gases 6. Oxidizers 10. Cryogenics 14. Other Health Hazards 3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic (Materials tSrJNone of These. 4. Flammable Solids 8. Unstable Reactives 12. Radioactives ^- PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HMD): If the answer to anv of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Ave., Suite 110, San Diego, CA 92123. Call (858) 505-6700 prior to the issuance of a building permit. FEES ARE REQUIRED. Project Completion Date: / / Expected Date of Occupancy:. / / 4. 5. 6. 7. • • • • • CalARP Exempt I Date Initials • CalARP Required / Date Initials • CalARP Complete / Date Initials (for new construction or remodeling projects) Is your business listed on the reverse side of this form? (check all that apply). ,^ Will your business dispose of Hazardous Substances or Medical Waste in any amount? Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds 200 cubic feet, or carcinogens/reproductive toxins in any quantity? Will your business use an existing or install an underground storage tank? Will your business store or handle Regulated Substances (CalARP)? Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? Will your business store petroleum in tanks or containers at your facility with a total storage capacity equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act). PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer to any of the questions below is yes, applicant must contact the Air Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the issuance of a building or demolition permit. Note; if the answer to questions 4 or 5 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days prior to commencing demolition or renovation, except demolition or renovation of residential structures of four units or less. Contact the APCD for more information. YES NO, 1 • D '•jEL- W'" subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the / ' APCD factsheet at http://www.sdapcd orq/info/facts/permits.pdf. and the list of typical equipment requiring an APCD permit on the reverse side of this from. Contact APCD if you have any questions). 2. • • (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? (Search the California School Directory at http://www.cde-ca.gov/re/sd/ for public and private schools or contact the appropriate school district). Has a survey been performed to determine the presence of Asbestos Containing Materials? . Will there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-friable asbestos? ^ Will there be demolition involving the removal of a load supporting structural member? Briefly describe business activities Briefly describe Qrt)posed project: Name of Owner or Authdfized Agent FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:. BY: FOR OFFICIAL USE ONLY: DATE: EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMD* APCD COUNTY-HMD APCD COUNTY-HMD APCD *A Stamp in this box onlv exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply. HM-9171 (02/1 1) County of San Diego - DEH - Hazardous Materials Division OJ > CO O O CD N) (fl cn 5 90