HomeMy WebLinkAbout2551 NAVARRA DR; ; CB070304; Permit. City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
03-19-200 77- Residential Permit Permit No: CB070304
- Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
2551 NAVARRA DR CBAD
RESDNTL Sub Type: RAD Status: ISSUED
2161705501 Lot #: 0 Applied: 02/05/2007
$12,980.00 Construction Type: VN Entered By: RMA
Reference #: Plan Approved: 03/19/2007
0 Structure Type: Issued: 03/19/2007
0 Bathrooms: 0 Inspect Area:
GRANT RES-ENCLOSE 72 SF DECK Orig PC#:
TO BECOME HABITABLE&REMOVE WALLS & KITCHEN WINDOW Plan Check#:
Applicant: Owner:
GRANT DYLAN P GRANT DYLAN P
2551 NAVARRA DR 2551 NAVARRA DR
CARLSBAD CA 92009 CARLSBAD CA 92009
Building Permit S $122.79 Meter Size
Add'l Building Permit Fee $0.00 Add'l Red. Water Con. Fee
Plan Check $79.81 Meter Fee
Add'I Plan Check Fee $0.00 SDCWA Fee
Plan Check Discount $0.00 CFD Payoff Fee
Strong Motion Fee $1.30 PFF (3105540)
Park in Lieu Fee $0.00 PFF (4305540)
Park Fee $0.00 License Tax (3104193)
LFM Fee $0.00 License Tax (4304193)
Bridge Fee '$0.00 Traffic Impact Fee (3105541)
Other Bridge Fee $0.00 Traffic Impact Fee (4305541)
BTD #2 Fee $0.00 Sidewalk Fee
BTD #3 Fee $0.00 •, PLUMBING TOTAL.
Renewal Fee $0.00 ELECTRICAL TOTAL
Add'l Renewal Fee $0.00 MECHANICAL TOTAL
Other Building Fee $000 Housing Impact Fee
HMP Fee $0.00 Housing lnLieu Fee
Pot. Water Con. Fee $0.00 Housing Credit Fee
Meter Size Master, Drainage Fee
Add'l Pot. Water Con. Fee $0.00 ' Sewer Fee
Red. Water Con. Fee $0.00 Additional Fees
TOTAL PERMIT FEES
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$20.00•
$24.00-
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$247.90
Total Fees: $247.90 Total Payments To Date: $247.90 Balance Due: $0.00
FIN 0
Insoector: E=~/_ Clearance: _
L4 Date: -
NOTICE: Please take NOTICE that approval of your project includes the imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as 'fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
PERMIT APPLICATION.
CITY OF CARLSBAD BlUILD"ING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008 -
'I- -
FOR OFFICE USE, ONL
PLAN CHECK NO. 4
\IAL. 7/.
Plan Ck. Deposit—
Validated By -717,
Address (include Bldg/Suite #)
,
Business Name (at this address) . .
Legal Description Lot No. - - Subdivision Name/Number -i-- Unit No. Phase No. 'Total # of units
Assessor's Parcel # Existing Use Proposed Use
Joescription of Work - SQ. FT. #of Stories - # of Bedrooms -- -# of Bathrooms
A.o,tgD 1W W(1t ,w ,J1 . 9iy14 to Th 1014 I417,410 fAW
..... --' --mom. - ,-ss from apphcant) - .
Name . . -- Address . City State/Zip '-Telephone #-' Fax #.
Name - - Address City . . State/Zip Telephone.# - .
)(7ILAfJ ff . st B2v. .o ç'
Name Address ' City, . State/Zip . Telephone //
.
-
(Sec. 7031 .5 Business and Professions Code: Any City. or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior io its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for ,the alleged.
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001).
Name '. . .. Address .- . City - State/Zip Telephone "#
State Liensi # . License Class . City Bisiness License #
Designer Name '- . -.,- Address ;' City State/Zip Telephone
State License #
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the LaborCode, for 'the- performance
of the work for which this permit is issued.
I-have and will maintain workers' compensation, -as required by Section 3700 of the Labor Code, for the performance of the work for which this 'permit is
issued. My worker's compensation insurance carrier and policy number are: -
Insurance Company Policy No. - - . Expiration Date_________________
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($1001 OR LESS)
CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California. . .
WARNING: Failure to secure workers' compensation coverage is unlawful. and shall subject an-employer to criminal penalties- and f civil fines up to one hundred
thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees.
SIGNATURE - , ' DATE
I heieby affirm that I am exempt from the Contractor's License Law for the following reason:
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is-j
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). - - -
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7.044, 'Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, irid contracts for such projects with contractor(s) licensed'
pursuant to the Contractor's License Law). - -
o I am exempt under Section Business and Professions Code for this reason:
I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO
I (have I havenàt) signed an application for a building permit for the proposed work.
I have contracted with the following person (firm) to provide the proposed construction. (include name / address / phone number / contractors licenée number):
I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address / phone
number / contractors license number):_-
I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address /,phone 'number / type
-'
/of work): tav~ftft ¶Efq-) ) 1 i'ctTf, 'i' teirr -
J.PROPER1'Y OWNER SIGNATURE - -. - . '9ATE - 6&O507
.JiAL-8 -
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? - 0 YES 0 NO - -. -
Is the applicant or future building occupant requird to obtain i perm it from the air pollution control district or air, quality management district? 0 YES 0 NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0. YES 0 NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. - - '
La L CONSTRUCTION LENDING AGENCY --" ''117, - "i
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). -
LENDER'S NAME - - LENDER'S ADDRESS
PUCANTCERT- ____
I certify that I have read the-applicationand state that the above information is correct and that the information on the plans is-accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon' the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE. INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES;
'-JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY INCONSEQUENCE OF THE GRANTING OF THIS PERMIT. - -
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height:
EXPIRATION: Every permit issued by i uilding Official under the pràvislons of this Code shall expire by limitation and become null and void lithe building or work
- authorized by such permit is not corn n ad Ahin 1ptday from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is common ed or eriod 1ø' days (Section 106.4.4 Uniform Building Code).
------
- - ---
'\ yP1ANT'S SIGNATURE - .. 2TSP ' .3DATE. - 00567 -
- - WHITE: File YELLOW: Applicant PINK: Finance
City of Carlsbad Bldg Inspection Request
For: 08/31/2007
Permit# CB070304 - Inspector Assignment:
Title: GRANT RES-ENCLOSE 72 SF DECK
Description: TO BECOME HABITABLE&REMOVE WALLS & KITCHEN
WINDOW
Type: RESDNTL Sub Type: RAD
Phone: 7606328085
Job Address: 2551 NAVARRA DR
Suite: Lot: 0
Location: Inspector:
OWNER GRANT DYLAN P
Owner: GRANT DYLAN P
Remarks:, PLEASE-INSPECT-AT-9AM—i
Total Time: Requested By: DILLION GRANT
Entered By: CHRISTINE
CD Description Act1, Comments
14 Frame/Steel/Bolting/Welding _frnC
q __Wi
t Commen
,
ts/Notices/Holds
Associated PCRs/CVs Original PC#
CV050795 CLOSED H- ILL ENCLOSED PATIO;
Inspection History
Date Description , Act Insp Comments
'.EsGiI• Corporation
In cPartnersliip with government for Bui(tuing Safety.
DATE: February 12, 2007
JURISDICTION: Carlsbad
PLAN CHECK NO.: 07-304 SET: I
PROJECT ADDRESS: 2551 Navarra Dr.
PROJECT NAME Grant Residence Addition and Remodel
O 6E - CANT
JURIS.
O PLAN REVIEWER
U FILE
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
El The plans transmitted herewith will substantially comply with the jurisdictiohs building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
LI The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
fl The applicant's copy of the check list is enclosed for the jurisdiction to forward to, the applicant
contact person.
III The applicant's copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
O Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ). ' . Fax #:
Mail Telephone Fax In Person -
[II REMARKS:•
By: Bill Elizarraras Enclosures:
Esgil Corporation
0 GA C] MB ,D EJ 0 PC 2/6/07 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
Car1s1ad 07-304 .
February12,2007 '.
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: .07-304
PREPARED BY: Bill Elizarraras . DATE: February 12,2007
BUILDING ADDRESS: 2551 Navarra Dr.
BUILDING OCCUPANCY: R3/U1 TYPE OF CONSTRUCTION: VN
BUILDING
PORTION
AREA
(Sq. Ft.)
Valuation
Multiplier
Reg.
Mod.
VALUE ($)
Dwelling Add'n 72 121.94 8,780
Remodel 120 121.94 . - - 14,633
Air Conditioning
Fire Sprinklers _
TOTAL VALUE .
23,412
Jurisdiction Code 1cb - lBy Ordinance
Bldg. Permit Fee by Ordinance I $207.49
Plan Check Fee by Ordinance [j I $134.871
Type of Review: I1 Complete Review fl Structural Only
El Other - El Repetitive Fee . Repeats Hourly I Hour *
Esgil Plan Review Fee I $116.191.
Comments: -
- Sheet of 1
macvalue.doc
ATTACHMENTS
0 Dedication Application
0 Dedication Checklist
0 Improvement Application
0 Improvement Checklist
El Neighborhood Improvement Agreement
O Grading Permit Application
0 Grading Submittal Checklit
O Right-of-Way Permit Application
o Right-of-Way Permit Submittal Checklist
and Information Sheet
City Of Ca*rlsba'd-
1 U&UII .IIAKSJtI
BUILDING PLANCHECK CHECKLIST
DATE: ______ PLANCHEC
BUILDING ADDRESS: ff /VitU-7ZA4
PROJECT DESCRIPTION:
ASSESSORS PARCEL NUMBER: /6 /7`0
ENGINEERING DEPARTMENT
NO.: CB 073O'
EST. VALUE:
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans,
information and/or specifications provided in your
submittal; therefore any changes to these items after
this date, including field modifications, must be
reviewed by this office to insure continued
conformance with applicable codes. Please review
carefully all comments attached, as failure to comply
with instructions in this report can result in
suspension of permit to build.
O A Right-of-Way permit is required prior to
construction of the following improvements:
DENIAL
Please see e aft ched report of deficiencies
marked wi . Mae' necessary corrections to plans
or speci n for compliance with applicable codes an standards. Submit corrected plans and/or
specifications to thioffice)for review. Only the
applicable sheets)ve beensent.
Date:
By: Date:
By: Date:
FOR OFFICIAL USE ONLY
ZWIK-EE;RII.4,G:AUTHORIZATI,ON.TO ISSUE BUILDING PERMIT:
Date ¼ 7
ENGINEERING DEPT. CONTACT PERSON
Name: KATHLEEN M. FARMER
City of Carlsbad
Address: 1635 Faraday Avenue, Carlsbad, CA 92008
Phone: (760) 602-2741
NOTE: If there are retaining walls
associated with your project, please check
with the Building Department if these walls
need to be pulled by separate RETAINING
WALL PERMIT.
A-4
CA 920cB-731 4 • (760) 602-2720 • FAX (760) 608562
- BUILDING PLANCHECK CHECKLIST -.
SITE PLAN. .
1ST 2N0 3R0
1. Provide a fully dimensioned site plan drawn to scale. Show:.
North Arrow . F. Right-of-Way Width & Adjacent Streets
Existing & Proposed Structures G. Driveway widths
Existing Street Improvements H. Existing or proposed sewer lateral
Property Lines (show all dimensions) I. Existing or proposed water service
Easements J. Existing or proposed irrigation service
2. Show on site plan:
A. Drainage Patterns
Building pad surface drainage must maintain a minimum slope of one
percent towards, an adjoining street or an approved drainage course.
ADD THE FOLLOWING NOTE:. "Finish grade will provide a minimum positive
drainage of 2% to swale 5' away from building."
B. Existing & Proposed Slopes and Topography
C. Size, type; location, alignment of. existing or proposed sewer and water service (s)
that serves the project. Each unit requires a separate service, however, second
dwelling units and apartment complexes are an exception.
D. Sewer and water laterals should not be located within propàsed driveways, per
standards. .
D El 3. Include on title sheet:
Site address
Assessor's Parcel Number -
Legal,Desciption
For commercial/industrial buildings and tenant improvement projects, include:
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc.) previously approved.
EXISTING PERMIT NUMBER DESCRIPTION
Show all existina use of SF and new ør000sed use of SF.
Example:
Tenant Improvement for 3500 SF of warehouse to 3500 SF of office.
F:Farmen)CathyMASTERSBuilding Plancheck Mist Form (Oenenc).doc 2 ' Rev. 7114100
BUILDING PLANCHECK CHECKLIST
1ST 2ND 3RD DISCRETIONARY APPROVAL COMPLIANCE
U U U 4a. Project does not comply with the following Engineering Conditions of approval for
Project No.______________________________________________________
U U U 4b. All conditions are in compliance. Date:
DEDICATION REQUIREMENTS
U U 5. Dedication for all street Rihts-of-Way adjacent to the building site and any storm
Ii drain or utility easements on the building site is required for all new buildings and ('I for remodels with a value at or exceeding $ 17.000 , pursuant to Carlsbad
Municipal Code Section 18.40.030.
Dedication required as follows:
Dedication required. Please have a registered Civil Engineer or Land Surveyor
prepare the appropriate legal description together with an 8 V2" x 11" plat map and
submit with a title report. r All easement documents must be approved and signed
by owner(s) prior to issuance of Building Permit. Attached please find an
application form and submittal checklist for the dedication process. Submit the
completed application form with the required checklist items and fees to the
Engineering Department in person. Applications will not be accept by mail or fax.
Dedication completed by: Date:
IMPROVEMENT REQUIREMENTS
/tj U U 6a. All needed public improvements upon and adjacent to the building site must be
cf V I constructed at time of building construction whenever the value of the
construction exceeds $ 82.000 , pursuant to Carlsbad Municipal Code Section
18.40.040.
Public improvements required as follows:
Attached please find an application form and submittal checklist for the public
improvement requirements. A registered Civil Engineer must prepare the
appropriate improvement plans and submit them together with the requirements
on the attached checklist to the Engineering Department through a separate plan
check process. The completed application form and the requirements on the
F:Faneñ)CATHVMASTERSBuiIdlng Planthedi Cklst Form (GenerIc).d 3 Rev. 7114100
1ST 2N0 3RD
BUILDING PLANCHECK CHECKLIST
checklist must be submitted in person. Applications by mail or fax are not
accepted. Improvement plans must be approved, appropriate securities posted
and fees paid prior to issuance of building permit.
Improvement Plans signed by: Date:
E U U 6b. Construction of the public improvements may be deferred pursuant to Carlsbad
Municipal Code Section 18.40. Please submit a recent property title report or
current grant deed on the property and processing fee of $ 400.00 so we may
prepare the necessary Neighborhood Improvement Agreement. This agreement
must be signed, notarized and approved by the City prior to issuance of a
Building permit.
Future public improvements required as follows:
U U U 6c. Enclosed please find your Neighborhood Improvement Agreement. Please return
agreement signed and notarized to the Engineering Department.
Neighborhood Improvement Agreement completed by:
Date:
U U U 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective
improvements found adiacent to building site must be repaired to the satisfaction
of the City Inspector prior to occupancy.
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section
11.06.030 of the Municipal Code.
0 0 0 7a. Inadequate information available on Site Plan to make a determination on grading
requirements. Include accurate grading quantities in cubic yards (cut, fill import,
export and remedial). This information must be included on the plans..
ij 0 0 7b. Grading Permit required. A separate grading plan prepared by a registered Civil
J \J Engineer must be submitted together with the completed application form
attached. NOTE:. The Grading Permit must be issued and rough grading
approval obtained prior to issuance of a Building Permit.
Grading Inspector sign off by: Date:
AIIthV IJ L1 7c. Graded Pad Certification required. (Note: Pad certification may be required even V if a grading permit is not required.)
FFamiOIihCATHYMASTERSBUIIdhIg Planclieck Cklsl Form (Oenertc).doc 4 Rev. 7114100
BUILDING PLANCHECK CHECKLIST
1ST 2ND 3RD
El U UI 7d. No Grading Permit required.
LI U UI 7e. If grading is not required, write "No Grading" on plot plan.
MISCELLANEOUS PERMITS
LI LI 0 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way. Types of work include, but are -.
not limited to: street improvements, tree trimming, driveway construction, tying
into public storm drain, sewer and water. utilities'.
Right-of-Way permit required for:
0 UI 0 9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you need to contact the Carlsbad Municipal Water District
located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List. You may telephone (760) 438-2722, extension. 7153,
for assistance. ••
Industrial Waste permit accepted by:
Date:
NPDES PERMIT
O 0 0 10a. Storm Water Requirements ApplicabilityChecklist Completed.
0 fl 0 lOb. Priority Determination and compliance:
o Priority Project El Subject to Standard Permanent Storm Water BMP's
0 Exempt •
UI 0 11. 0 Ooqdi red fees are attached
allo fees required • .
WATER METER REVIEW •'
•
O 0 0 12a. Domestic (potable) Use .
Ensure that the meter proposed by the owner/developer is not oversized.
Oversized meters are inaccurate during low-flow conditions. If it is oversized, for
the life of the meter, the City will not accurately bill the owner for the water used.
All single family dwelling units received "standard" 1" service with 5/8" service.
F:rFarmeiKAHYMASERSrSuI0I1,g PIanched Cklst Form (Gener1c).doc 5 .
. Rev. 7114100
BUILDING PLANCHECK CHECKLIST
1ST 2ND 38D
If owner/developer proposes a size other than the "standard", then
owner/developer must provide potable water demand calculations,
which include total fixture counts and maximum water demand in gallons
per minute (gpm). A typical fixture count and water demand worksheet is
attached. Once the gpm is provided, check against the "meter sizing
schedule" to verify the anticipated meter size for the unit.
Maximum service and meter size is a 2" service with a 2" meter.
If a developer is proposing a meter greater than 2", suggest the
installation of multiple 2" services as needed to provide the anticipated
demand. (manifolds are considered on case by case basis to limit
multiple trenching into the Street).
EJ E E 12b. Irrigation Use (where recycled water is not available)
All irrigation meters must be sized via irrigation calculations (in gpm) prior
to approval. The developer must provide these calculations. Please follow
these guidelines:
If the project is a newer development (newer than 1998), check the recent
improvement plans and observe if the new irrigation service is reflected on
the improvement sheets. If so, at the water meter station, the demand in
gpm may be listed there. Irrigation services are listed with a circled "I",
and potable water is typically a circled "W". The irrigation service should
look like:
i-I O STA 1+00 Install 2" service and
L_J 1.5: meter (estimated 100 gpm)
If the improvement plans do not list the irrigation meter and the
service/meter will be installed via another instrument such as the building
plans or grading plans (w/ a right of way permit of course), then the
applicant must provide irrigation calculations for estimated worst-case-
irrigation demand (largest zone with the farthest reach). Typically, Larry
Black has already reviewed this if landscape plans have been prepared,
but the applicant must provide the calculations to you for your use. Once
you have received a good example of irrigation calculations, keep a set for
your reference. In general the calculations will include:
Hydraulic grade line
Elevation at point of connection (POC)
Pressure at POC in pounds per square inch (PSI)
Worse case zone (largest, farthest away.from valve
Total Sprinkler heads listed (with gpm use per head)
Include a 10% residual pressure at point of connection
3. In general, all major sloped areas of a subdivision/project are to be
irrigated via separate irrigation meters (unless the project is only SFD with
no HOA). As long as the project is located within the City recycled water
F:FarmeIiXQthyMASTEflS8uiId1ng Ploncheck Ciii,, Form (Generic)doc 6
1 Rev. 7114=
1ST 2 ND 3R0 BUILDING PLANCHECK CHECKLIST
service boundary, the City intends on switching these irrigation
services/meters to a new recycled water line in the future.
El 0 El 12c. Irrigation Use (where recycled water is available)
Recycled water meters are sized the same as the irrigation meter above
If a project fronts a Street with recycled water, then they should be
connecting to this line to irrigate slopes within the development. For
subdivisions, this should have been identified, and implemented on the
improvement plans. Installing recycled water meters is a benefit for the
applicant since they are exempt from paying the San Diego County Water
Capacity fees However, if they front a Street which the recycled water is
there, but is not live (sometimes they are charged with potable water until
recycled water is available), then the applicant must pay the San Diego
Water Capacity Charge. If within three years, the recycled water line is
charged with recycled water by CMWD, then the applicant can apply for a
refund to the San Diego County Water Authority .(SDCWA) for a refund.
However, let the applicant know that we cannot guarantee the refund, and
they must deal with the SDCWA for this.
WAM 13. Additional Comments:
/
Off r /E•itt..4f E# C/" i_-e~
F.WarmeñKaIhyiMASTERS8uiIding Plancheck Chict Fonn (Genenc).dac 7 Rev. 7/14100
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No. CBO ) Address
Planner Erin Endres Phone(760)602- 4625
dU Type of Project & Use: (4tV.J' d5)v1 Net Project Density:DU/AC
. Zoning: 4M General Plan:__________ Facilities Management Zone:
CFD (In/out) #_Date of participation:. Remaining net dev acres:______ >.
V'E Circle One (For non-residential development: Type of land used created by this
-.
.
permit:______________________________________________
Legend: Item Comp!et 9/Item Incomplete - Needs your action
/,RE] 0 Environmental Review Required: YES NO_.CTYPE
DATE-OF COMPLETION:
Compliance with conditions of approval?. If not, state conditions which require action.
. Conditions of Approval:
0 0 Discretionary Action Required: YES NO kTYPE
APPROVAL/RESO. NO. DATE_____
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:__________________________________________________________
)RrEl 0 Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES____ NO .2(
CA Coastal Commission Authority? YES____ NO____ If California Coastal Commission Authority: Contact them at — 7575 Metropolitan Drive, Suite 103,. "-- San Diego CA 92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt):
Coastal Permit Determination Form already completed? YES NO____ If NO, complete Coastal Permit Determination Form noi'
Coastal Permit Determination Log
Foilow-UpActions:-.. • .. .,..
Stamp Building Plans as "Exempt" or' "Coastal Permit Required" (at minimum Floor Plans).
Complete Coastal Permit Determination Log asnéeded. . P
-ED 0 IncIusionary Housing Fee required YES NO—>K
(Effective. date of Inclusionary Housing Ordiriance -May 21, 1993.)
,. .1 •1 . * -• ,. ) .. •.
Data Entry Completed? YES NO ____
(NP/Os, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N,
Enter Fee, UPDATE!)
H:AOMlNCOUNTERBidgPlnchkRevChkist
- . Rev 9/01
Site Plan:
.D 0 1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property -lines,
.easements, existing and* proposed structures, streets, existing street improvements, right-of-way
width, dimensioraI setbacks and existing topographical lines (including all side and rear yard, _
slopes).
0 2. Provide legal description of property and assessors parcel number -
Policy 44- Neighborhood Architectural Deslfl G'uidelines ,'' : -
0 0 1. Applicability: YES NO________
0 EJ 2. Project complies YES NO________
Zoning: .
0 0 Setbacks: -
Front: - ; Required . Shown
Interior Side: - Required Shown
Street Side: Required Shown
Rear: Required Shown
Top of slope: : Required Shown
El 0 Accessory structure etbacks: -
Front Required Shown
Interior Side: Required Shown
Street Side: Required Shown
Rear: Required Shown
Structure separation: Required . Shown
)1. El 0 Lot Coverage: Required Shown
Height:
.
Required Shown
Jt 0 0 Parking:. Spaces Required Shown
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required Shown
0 Additional C mments &{'. -J'
If'
V ' v'rCt1 Y\T0UV 'kLZ.
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER V'-- DATE 2-
H:ADMIMCOUNTERBIdgPInchkRevChkIst Rev 9/01
Civil Engineering
Land Planning
Structural
Surveying
November 29, 2006
CITY OF CARLSBAD - BUILDING DEPARTMENT
1635 Faraday Ave.
Carlsbad, CA 92008
RE: Dylan Grant Residence Remodel - City of Carlsbad
2551 Navarra Dr.
Carlsbad, CA 92009
To Whom It May Concern:
This letter is in response to the Notice of Illegal Construction dated September 12, 2005 for the
unpermitted improvements made to the above residence. This letter shall serve as a supplement to the
submittal to retroactively permit said improvements and clarify the structural analysis performed and
structural impact. The structural analysis. was based on the record as ;built construction documents by
Robert F. Ardent Architect dated 10/23/80 on file at the City.
An overall structural analysis was first performed to verify the existing framing could support the new
loading conditions and determine if the improvements made have compromised any existing structural
elements. Under vertical analysis it was found that the existing framing members remained well within the
allowable limit states under the new loading conditions. Further, it was determined that the improvements
involving the removal of an interior kitchen wall and the new pass-thru opening in the adjacent wall did
not compromise the existing gravity-load structural elements. However, the interior kitchen wall that was
removed was found to be a shear wall.
Upon further review, it was determined said shear wall was comprised of 1/2", gyp. board each side with
8d coolers at 4" o/c and was responsible for a, tributary area consisting of the middle third of the uppermost
floor system and did NOT include any roof tributary. Said shear wall was designed to transfer the lateral
loads to the floor diaphragm below which then redistributes the loads to adjacent shear walls.
A lateral analysis was then performed using 2001 CBC lateral loading to determine the impact and
performance of the remaining lateral-load resisting elements given the loss of the shear wall. It was found
that the remaining shear walls could not support the additional lateral loading due to the loss of the wall.
Further, it was determined that none of the existing plywood/gyp. board shear walls could resist any of
the-2001 CBC seismic loading conditions had the kitchen shear wall remained in place or not.
Given this information, it is my professional opinion that relative to balance of the lateral load resisting
system remaining in place, the removal of the kitchen shear wall does not significantly compromise the
performance of the-structure. Furthermore, it needs to be recognized that a lateral analysis of a given unit
does not reflect the true performance of the structure. Under a seismic event the structure will perform as a
whole and not as an individual unit. The shear wall in question lies in the longitudinal direction of the
building and represents and extremely small portion of the entire lateral load resisting system in that
direction relative to the building as a whole.
Office: 1635 S. Rancho Santa Fe Road, #204 • San Marcos, CA 92078
Mailing: 132 N. El Camino Real, PMB-N • Encinitas, CA 92024
Phone 760-510-3152 • Fax 760-510-3153
Email: dlogan@dlogan.connectnet.com
The lateral loads the kitchen shear wall is responsible for will ultimately be supported by the balance of the
interior walls, which in turn redistribute the loads through the floor diaphragm to adjacent shear walls. It is
my opinion the remaining interior walls sheathed with gyp. board (not called out as shear walls) are more
than capable of resisting the loading the kitchen shear wall was originally, designed for. Ultimately all of
the longitudinal lateral loads are-transferred though the floor diaphragm to the CMU basement wall and
garage portals that have not been compromised or altered in any way by the improvements.
It is my professional opinion that requiring an additional structural element or retrofit of the remaining
elements to comply with 2001 CBC standards to address the loss, of the kitchen shear wall would require
the balance of the structural to comply with 2001 CBC standards. It is my opinion that doing so would
cause an undo hardship for the owner and would ignore a) the relative lack of importance and role of the
removed shear wall with respect to the original lateral design, b) the remaining interior longitudinal walls
sheathed with gyp. board and c) the structural advantages inherent to the building as a whole in the
longitudinal direction.
Given the above information and understanding, it is my professional recommendation that the removal of
the kitchen shear wall be allowed and permitted without any further structural lateral improvements.
Please feel free to call me at (760)815-1161 if you have any additional questions.
Sincerely, , OESSIO*
.4RILL
Dan Hayden, PE ,, ( No.c66598
1.