Loading...
HomeMy WebLinkAbout2552 Wellspring St; ; CBRA2017-0127; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Print Date: 12/21/2017 Permit Permit No: CBRA2017-0127 www.carlsbadca.gov Job Address: Permit Type: 2552 Wellspring St BLDG-Associated Permit Residentia 2081912600 Work Class: Single Family Detached 169 Status: Closed -Finaled Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: $535,359.24 1 5.00 THE VISTAS Lot#: Reference #: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: DEV2016-0039 VB 5.50 PC150042 PC2016-0065 Applied: 02/23/2017 Issued: 07/18/2017 Fina led: Inspector: CRenf Description: THE VISTAS: PHASE 8 / PLAN 3 / LOT 169 / 3,352 SF LIV/ 425 SF GARAGE/ 184 SF PATIO/ 280 SF CA ROOM Applicant: TOLL BROS INC JOANN EPSTINE Owner: RANCHO COSTERA LLC -2483 725 W Town And Country Rd, 200 ORANGE, CA 92868-4709 760-720-5485 725 W Town And Country Rd, 200 ORANGE, CA 92868-4723 714-347-1300 BUILDING PERMIT FEE $2000+ BUILDING PLAN CHECK FEE (BLDG) COMMUNITY FACILITIES DISTRICT (CFD) FEE ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -inside CFD SB1473 BUILDING STANDARDS FEE SDCWA SYSTEM CAPACITY CHARGE 5/8" Displacement SEWER BENEFIT AREA FEES -B SEWER CONNECTION FEE (General Capacity all areas) STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1-Medium BLDG TRAFFIC IMPACT Residential Single Family w/in CFD WATER METER FEE 1" Displacement WATER SERVICE CONNECTION FEE 5/8" DISPLACEMENT (P) WATER TREATMENT CAPACITY CHARGE 5/8" Displacement Total Fees: $30,338.62 Total Payments To Date: $30,338.62 Co-Applicant: TOLL BROS INC 725 W Town And Country Rd, 200 ORANGE, CA 92868-4709 760-720-5485 Balance Due: $0.00 $2,145.00 $1,381.38 $1,723.10 $96.00 $166.00 $110.00 $224.00 $9,743.54 $22.00 $5,029.00 $1,255.00 $899.00 $69.60 $232.00 $2,740.00 $362.00 $4,013.00 $128.00 . . . ' ... . PERMIT INSPECTION HISTORY REPORT (CBRA2017-0127) Permit Typo: BLDG-Associated Permit Residential Application Date: 02/23/2017 Owner: Work Class: Single Family Detached Issue Date: 07/18/2017 Subdivision: Status: Closed -Finaled Expiration Date: Address: IVR Number: 5081 Scheduled Date Actual Start Date Inspection Type Inspection No. Inspection Status Primary Inspector 11/22/2017 11/22/2017 11/28/2017 11/28/2017 12/21/2017 12/21/2017 December 21, 2017 BLDG-Electric Meter 041277-2017 Release Checklist Item BLDG-Building Deficiency BLDG-Fire Final 041684-2017 BLDG-Final Inspection Checklist Item FIRE-Building Final 044092-2017 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Passed Chris Renfro COMMENTS Passed Daniel Stowe COMMENTS Passed Chris Renfro COMMENTS RANCHO COSTERA LLC -2483 2552 Wellspring St Carlsbad, CA 92010-5604 Reinspection Complete Complete Passed Yes Complete Passed Yes Complete Passed Yes Yes Yes Yes Yes Page 2 of 2 PERMIT INSPECTION HISTORY REPORT (CBRA2017-0127) Permit Type: BLDG-Associated Permit Residential Application Date: 02/23/2017 Owner: RANCHO COSTERA LLC -2483 Work Class: Single Family Detached Issue Date: 07/18/2017 Subdivision: Status: Closed -Finaled Expiration Date: Address: 2552 Wellspring St Carlsbad, CA 92010-5604 IVR Number: 5081 Scheduled Actual Inspection Status Reinspection Complete Date Start Date Inspection Type Inspection No. Primary Inspector 07/20/2017 07/20/2017 BLDG-81 029324-2017 Passed Chris Renfro Complete Underground Combo{11, 12,21,31) Checklist Item COMMENTS Passed BLDG-21 Inspected underground waste and water. Yes Underground-Underfloor Ok Plumbing 07/24/2017 07/24/2017 BLDG-21 029445-2017 Passed Chris Renfro Complete Underground/Underf loor Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 07/31/2017 07/31/2017 BLDG-11 030153-2017 Passed Chris Renfro Complete Foundation/Ftg/Pier s (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 09/07/2017 09/07/2017 BLDG-15 033944-2017 Passed Chris Renfro Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 09/14/2017 09/14/2017 BLDG-13 Shear 034753-2017 Passed Chris Renfro Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 09/25/2017 09/25/2017 BLDG-84 Rough 035630-2017 Passed Chris Renfro Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolling-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 09/29/2017 09/29/2017 BLDG-17 Interior 036310-2017 Passed Chris Renfro Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes December 21 , 2017 Page 1 of 2 «~~ ~ CI TY OF CARLSBAD Building Division INSPECTION RECORD 0 l~SPECTION RECORD CARD WITH APPROVED l_, l-.() T l (oC} f{Q n s SC CBRA2017-0127 2552 WELLSPRING ST THE VISTAS: PHASE 8 / PLAN 3 / LOT 169 / 3,352 SF LIV I 425 SF GARAGE/ 184 SF PATIO/ 280 SF CA ROOM 1 A.NS MUST BE l(EPT ON THE JOB 0 '-ALL BEFORE 3:00 pm FOR NEXT WORI( DAY INSPECTION 1 DEV2016-0039 2081912600 7/18/2017 0 FOR BUILDING INSPECTION CALL: 760-602-2725 OR GO TO: www.Carlsbadca.goxfBuilding AND CLICI( ON "Request Inspection" DATE: 1 -1q -1--r PC2016-0065 CBRA2017-0127 IF MARl(ED 'YES", IT IS REQUIRED PRIOR TO ANY CONSTRUCTION STORM WATER PRECON MEETING REQUIRED 760-602-2725 Allow 48 hours IF MARl(ED 'YES", IT IS REQUIRED PRIOR TO REQUESTING BUILDING FINAL Fire Prevention Planning/Landscape CM&I (Engineering Jnspecllonst #11 #12 REINFORCED STEEL #66 MASONRY PRE GROUT I " 0 GROUT O WALL DRAINS "\ _.)'TILT PANELS #11 POUR STRIPS #11 COLUMN FOOTINGS #14 SUBFRAME O FLOOR O CEILING #15 ROOF SHEATHING #13 EXT. SHEAR PANELS #16 INSULATION #18 EXTERIOR LATH #17 INTERIOR LATH & DRYWALL #51 POOL EXCA/STEEL/BOND/FENCE #66 PREPLASTER/FINAL #21 #24 #27 #23 #25 WATER HEATER #28 SOLAR WATER #600 PRE-CONSTRUCTION MEETING .l FOLLOW UP INSPECTION ,.~i,J NOTICE TO CLEAN #607 WRITTEN WARNING #609 NOTICE OF VIOLATION #610 VERBAL WARNING 760-602-4660 Allow 48 hours 760-944-8463 Allow 48 hours 760-436--389 l Call before 2 pm #33 LECTRIC SERVICE O TEMPORARY #35 PHOTO VOLTAIC #53 ELEC/CONDUIT/WIRING #39 FINAL CODE # MECHANICAL #41 UNDERGROUND DUCTS & PIPING #44 0 DUCT & PLENUM O REF. PIPING #43 HEAT-AIR COND. SYSTEMS #49 FINAL CODE# COMBO INSPECTION #81 UNDERGROUND (11,12,21,31) #82 DRYWALL,EXT LATH, GASTES(17,18,23) #83 ROOF SH EATING, EXT SHEAR (13,15) #84 FRAME RO UGH COMBO (14,24,34,44) T-Bar (14,24,34,44) FINAL OCCUPANCY (19,29,39,49) A/S UNDERGROUND HYDRO A/S UNDERGROUND FLUSH A/S OVERHEAD VISUAL A/S OVERHEAD HYDROSTATIC A/S FINAL F/A ROUGH-IN F/A FINAL FIXED EXTINGUISHING SYSTEM ROUGH-IN FIXED EXTING SYSTEM HYDROSTATIC TEST FIXED EXTINGUISHING SYSTEM FINAL MEDICAL GAS PRESSURE TEST MEDICAL GAS FINAL Date Ins ector SEE BACK FOR SPECIAL NOTES Michael Baker INTERNATIONAL July 27, 2017 City of Carlsbad Building Department 1635 Faraday Avenue Carlsbad, CA 92008 Subject: Inspector: Vistas -Lots 169, 170, 171, 193, 194, 195, & 196 City of Carlsbad Tract No. CT 13-03 JN 143824 Michael Baker International has performed a field survey on July 26, 2017 to field check the building footing forms for Lots 169-171 & 193-196 on Wellspring Street. The results of the field survey reveal the footing forms to be within substantial conformance, both horizontally (0.1 O'±.) and vertically (0.05'±.) with the City of Carlsbad approved precise grade plans DWG 480-3C, dated February 9, 2016. Sincerely, Tim Thiele, P.E. Project Manager H:IPDATAl143824_R0BERTS0N RANCHIADMIN\CORRESPNDNCIFORM CERTSITOLL BRO_F0RM_PA6_CERT11_ 169-171_ 193-196.D0C PLANNING Ill! DESIGN 1111 CONSTRUCTION 5050 Avenida Encinas, Suite 260, Carlsbad. California 92008 # 760.476.9193 # FAX 760.476.9198 Offices located throughout the Country • www.mbakerintl.com ~ ., { i.. ~--·· -Southwest Inspection and Testing, Inc. 441 Commercial Way, La Habra, Ca 9063.1 {562) 941-2990 • (714) 526-8441 • Fax (562) 94&-0026 I REGISTERED INSPECTOR'S DAILY REPORT I SWIT.Job No. /$0 =>{<.../ I Date/ ~ r -Z e Ii TYPE OF ~ Reinforced Concrete u Welding U DIA/Epoxy INSPECTION Post Tensioned Concrete D Fireproofing D Wood Framing REQUIRED D Reinforced Masonry D Asphalt D Other " Job Address~ ~-<-1'51uo V'\.I Tract No. L~t No"/ (A _)-, ~ Job Name VI S\/~~ Per~~~ ~~C \..N Issued Bls F3 ,Q C..A 1-t. • A ., ."T:Yp~ of Structure S,o .G. .., Architect ( f~· _ ... v\, .A ,~t~rJal. Description (type, grade, source) Engineer t"--.. <...A..M. (_.oA., ~f .. ;~o,'!t·.,,~~,t. A -~~~i~ <---Y-z_ .. ..-/S 7:., o1 <:. IA C//(_ Contractor IG<.....<-5r2c;,n~c. ln~pector's Name rs J.'.1' I (o/,· "' I C.N Subcontractor S~c...aA--s f" "" TESTS PERFORMED ; SAMPLE AIR CONC WATER TIME SET# TRUCK#· TICKET# LOCATION SLUMP TEMP TEMP ADDED CAST MIX# REMARKS . .. INSPECTION SUMMARY-LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS, ETC. INCLUDES INFORMATION ABOUT -AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER. TYPE & !DENT. NO'S OF ~T SAMPLES TAKEN: STRUCT. CONNECTIONS (WELD MADE H.T. BOLTS TORQUED) CHECKED ETC. -f1Zi't--i,,vc S t'?E.l..-Tt"u0 L.Ot':,, ~ l&:,1 -~ /7 / - - 0 f:,-S, p ..(2..,~ ·':::> -n~ lv4-1.. ( -0(/{/ L\ (? L-...A<~Fc..vl. T o < ~.'.:>O.A'S .( Y-e,1' cA ~~,~~ I -5~,<:::-, r7.--~, ,I Pa<.c. ~ t ~ I ~ ! 1VAY~QA/,AJ2.re_ ~. <;._ o . (.._ ~({ t:1 '1 rt lro e,' IF lr f _ - -~.A.<:, p~~ A~ ___,,/16.-1-0~ Przr;0.Cr-.R. 'St C:....-€..s ' { r,T It /(/j · -z s-s z. -v,/\~1 J "? ie>rz l lA t ., 'Sr. -11-CfSrZA Z...c.>I 7 -o I '2 7 ,, #-1 70 cs<-1 8 ,, .. , " ii c_ ~(2A c. 01 7 . olz::. \ ti I 71 Z.<:4 '-I I; . #: r 1-, '? 0 1, -c,1?.7 CERTIFICATION OF COMPLIANCE CONTINUED ON NEXT PAGE 0 PAGE OF TIME IN TIMEOUT SAMPLES SPECIALTY NO. AGENCY White -Office Copy • Canary-Accounting Copy • Pink -Inspector's Copy • Goldenrod -Jobsite Copy sm F-049 ©Southwest,lo._spection &. Testing, Inc. 0 0 Project Name: Project No.: Date: Report No.: l"l ' 11~,L zs. 10 7/zc._ /,7 _.,,,.. " -J; J/ 'I<,-,• . r:-/( An'L,1 n/ ·,Sr.A..> ,_;, L J.l, <..~t-·J,' 1Location: Author: T I Day: (circle one) \,J £. i__;,.> rY~./ i! I, De /,.. .--:--. +-·rfr. e I Jll/l , , -,., -M T w TCT)S s I ~ii. E:..L....,,. h r4 r? · , , ,, " ~ Ah /-, c... Client: Superintendent: Contractor: Foreman: ~----... }_41~F-~. -... .. . . ··-.. L, / ~ 1~ilt.Ri ---c:,,,,_·.£ ,...1,,;__ i l, I 1 /3;i--.5 Soil Engineer: Geologist: Weather: ( circle one) 7 { '+ ) I~ .,i,,, . ') ,,Suririi:, Overcast Rainy Other: Unit/Phas~/L~:-1 Plan File No. Permit No.,; ·Ct;;r../J :2L."!. ....__.,-!(;-',. ,~. !7 ' ! 'J?·.~1~ It CJ-/7 J )() 3 · /CJ!.., ' '1' ·t ,~ l 'N ·C·'.\1 ,.,,..,...,(,• 1t\:',,r-,.1 [., Footing Observation Summary: I C'/6 .()/ n Initials: ~ A representative of LGC Valley, Inc. observed the on-site soil conditions. The soil conditions at 7h.""-Jn Date: the site are substantially in c~nformance with those assumed in the geotechnical report. .. , ' Initials: Jf'v' A representative of LGC Valley, Inc. observed the footing excavation(s). The footing Date: Iii" I, excavation(s) extend into the proper bearing strata and are in general conformance with the 1 l recommendations of the geotechnical report. --rJ11 ! /)-'fl. I .. ,: l,£,-; ',Jt; /. ~ / hlA".-;v1, > F:.. i.. fuu0,.;t.. .rLi,,.1 ,;;: ~'l>IL'l Initials: \ J *· • ·,c. V / j /(_'.C) J1t., /JJ J~'1 . 1'9~ (1; An..; 1€.Jb /W .. !/,r ,~:,.:;:,l(:.., ,~ /)_p, -,) '7".,. /. ..-; .~ "' L,,,--> ' Date: , . ; .. I .. ·,. , I, I ' ' Notes: ' 1. Footing excavations should be cleaned of loose soil and debris and thoroughly moistened just prior to placing the concrete. 2. Line and grade of the footing excavation(s) are not part of the purview of LGC Valley, Inc. 3. In the event of a site change subsequent to our observation of footing excavations and prior to concrete placement (i.e. heavy rain, a construction/placement delay, etc.), LGC should be contacted to perform a recheck of footing excavations and site observations, as necessary. ' -1 .-/ ., , I rj/J ,./ 1J ! II Ii l ·1 7 /.;•,, /, 7 'ZD For LOC \i1311el, Inc. Date ' ' -I Technician Hours FOOTING OBSERVATION Received by: I ~-:: .. >·:. LGC VALLEY, INC. .. ----'-1" . SUMMARY i ( Geotechnical Consulting Print: i /. I .__)( I • > J. ·1 j, J ,.. 1, i• ' I {j White -File Copy Yellow -Client Copy Pink -Field Copy Gold -ClienUAgency Copy