HomeMy WebLinkAbout2553 LUCIERNAGA ST | 2555 LUCIERNAGA ST; ; 82-247; Permit~ : :5
frl 0
"' i[
0 u
~ ., s ~ .. z ~
z 0 ;:: .. "' z .. .. ,.
0 u
"' ir .. "' "' i
![
0 I her1 /firm that I am licensed under
provision, <rt Chapter 9 (commencing wilt,
Section 7000) of Division 3 of the Business
and Professions Code, and my license is In
full force and effect
L,c No Class
I hereby affirm that I am exempt from the Contrac·
tor's License Law for the following reason {Sec. 7()31 5
Business and Professions Code: Any c,ty or county which re-
quires a permit to construct, alter, improve. demolish, or
repair any structure, prior to its issuance also requires lhe ap-plicant lor such permit to file a signed statement that he is
l,censed pursuant lo the provisions ot the Contractor's
License Law (Chapter 9 commencing with Section 7000 of D1v1s1on 3 of the Business and Pro!essrons Code) or that is ex·
empt therefrom and the basis for the alleged exemption. Any
v1olat1on oi Section 7031.5 by an applicant for a permit sub
1ects the applicant to a civil penalty of not more than five hun·
dred dollars ($5001
:J I, as owner of the property, or my employees with wages
as l)rn1r sole compensation. will do the work. and the struc· ture 1s not intended or o1tered tor sale (Sec. 7044, Business
and Professions Code The Contractor"s License Law does
not apply to an owner of property who builds or improves
thereon and who does such work himself or through his own
employe-es. provided that such improvements are not intend-ed or offered for _sale If, however, the building or improve·
m_ent Is sold w1thm one year of completion, the owner-builder
will have the burden of proving that he did not build or 1m·
prove tor the purpose of sale)
C l,_as owner of th€ property, am exclusively contracting
with licensed contractors to cons1ruc1 the proiect (Sec. 7044
Business and Professions Code: The Contractor's License
Law does not apply to an owner of property who builds or im• proves !hereon, and who contracts for each pro1ects with a
E~~ector(s) license pursuant to the Contractor"s License
□ As a homeowner I am improving my home, and the tallow-ing conditions exist
1 The work 1s being performed prior to sale 2 I _have lived In my home for twelve months
prior to comple110n of this work 3. I have not claimed this exemption during the last throo years
n lamexemptunderSec _______ B&P.C for this reason ____________ _
O I hereby attirm that I ha.-e a cert11'ca1e of consent
to sell-,nsure. or a certificate of Workers Compensation Insurance. or a cert,l,ed cooy !hereo!
(Sec 3800. Labor Code)
POLICY NO __
COMPANY
~•s1'1edw,ththec,~
D Certified copy 1s hereby furn,shed
CERTIFICATE. OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section nee<! not be completed ,1 the permit
Is tor one hundred dollars 1s1001 or Iess1
0 I certify that "' the perlormance of !he wor1< •or wh,ch 1h1s perrrnt ,s ,ssued. I shall no! employ ;my
pe,son ,n any manner so as to become subIect to
the Wori<ers· Compensa!>on Laws ot Callforn,a
NOTICE TO APPLICANT If. after makIn1 this Cert,
t,ca!e of Exemption_ you sl1ould become sub1ect l'l
the Worllers· Compensat,on pro-,s1ons ot !he Labor Code. you mus! fonhw,th comply with such
prov1sIons or !hrs permII shall be deemed revoked
0 I hereby atf,rm 111a1 111ere Is a cons1tuc1,o~
lendrng agency for the per1ormance ul lhe worl< l0<
wh,ch th,s perrr,t ,s ,ssued (Sec 3097, C,v1• Code1
Lenders Name ___________ _
L!,noer s Address __________ _
USE BALL POINT PEN ONLY & PRESS HARD APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS.
CARLSBAD ' ·•LDING DEPARTMENT
1200 Elm, Carlsbad, 1fornia 92008-1989 (714) 438-5525 AF
;;;:;5./-v.rf ..r L.vc, f!,.P. rJ ~Ir-
oviNER'S NAME
Air:r/JJ•ri.Air::;;
71!=.h .
OwNER'SMAtL
°2-?I
1-\?ll BLt'?
; '-' At:J"[)AES,
., j
'1.A-,.
.M•
~c;~;K
CONTAACTO"f't'S
/$1,,,~
0ESIGNEh
li,rnoN OF WOl<K t ~I:'< /,l:>~ r:iA-L l,, ~x. ,!!.ES>G"E~'S AO[!R.E~
--' . . ~ ,1, ': ~; 'B 12 f5'1>PN 1)0; ,---·• ~ ,\,i
FLR ELEV.
NO
CENSUS TRACT
GP LAND USE [IM,;;~~E REVTS l
QTY.I PLUMBING PERMIT. ISSUE 1 7 2-
GRADING f".ERMIT ISSUED
y D ND
flEDEVELOPMENT
AREA
vD Nat(
~
QTY. MECHANICAL PERMIT -ISSUE
NO
~ [R
EACH FIXTURE TRAP __ "_ I (po. __ INSTALL FURN_ oucrs uP rn 100.000 BTU ~
EACH BUILDING SEWER _ _j~ ,-____ OVER lDO,OOO_B_T_U __ +---
3~ -,
EACH WATER HEATE.R ANOIOR VENT _ t f--BOILER/COMPRESSOR UP TO 3 HP
EACH GAS SYSTEM__]..!.? 4 OUTLETS ---I _J;___-BOILER/COMPRESSOR 3-15 HP -
EACH GAS SYSTEM 5 OR MORE l ------. _ ---------fr-r-' --
!CATION & PERMIT
BUSINESS LICENSE# VALUATION PERMIT NUMBER
~Q?
CONTRACTORS PHONE It
1-71,.t.,~ i-v -"Y4-7
LICENSE NO. I PLAN 1.0. #
~..i"? n ~ BLDG USE CODE
LICl;NSE # I STANDARD PLAN# BUILDING SO. FOOTAGE
i / fh) )(. ,.__.,
.0,E.SIG~EJt'S PH()fll'°
°R-~ EDU
""2,.---
0CC LOAD FIRE SPA
,□,.,.,,. Not Valid Unless Machine Certified
SUMMARVACCOUNTNUMBER
-✓ b.fJ,Jo
EACH INSTA~ .. ALTER, REPAIR WAT.0E:CR'..'.P.'.l'..'.PE._ __ -I-
EACH VACUUM BREAKER
WATER SOFTNER
··---·------+-
~ I VENT FAN SINGLE DUCT
MECH EXHAUST -HOQ0.10UCTS --+---t--
RElOCATI0 N OF EA FURNACE/HEATER
, • MECHANICAL ____ 01-00-00-82241 .-v!, -1
MOBILEHOME 01-00-00-8225 <-----------1.
~
MOBILEHOME_PARK 0l~NS~P __ _ ------
(:fll "-0 I EACH ROOF DRAI_N_1_,!IJ_S_ID_E_I ___ _ r=-------j TOT.C.l MECHANICAL STRONG MOTION ----80-92-33-0519 ----/ :;>, -Z.:-IA-
TOTAL PLUMBING _____ FIRE SPRINKLERS 01-_00-00-8227 . 1Jtr __
01-00-0D-8226
~ -PUBLICFACIUTIEffi°~ 32-00-00-8923 --~~ -QTY. ELECTRICAL PERMIT -ISSUE QTY. SOLAR· ISSUE · ---
BRIDGE FEE
.., ___ : NEW CON-ST EA AMP 'SWT 'BKR l.()n-w COLLECTORS ---------c,...-:=--+---'c---11-_ S~E -DISTRICT
1 PH 3 PH STORAGE TANKS Ci'lrlsbad 80-92-21-0519
------
EXIST BLOG EA AMP,iSWT/BKR
I PH
AEMODEL'ALTER
------3 PH
---+-------------,f---======= ~.L---1,b,c..l>c-'-+---I-'---➔ .. --~ --~-----i:~_s_rn_,_A_G'__ -~.l'--~-'--+-~t--'----11---_-!:~i~~~~uito -----:~~::~::~~~:__ ---~~~--. -
PER CIRCUIT ----
TEMP POLE 200 AMPS
OVER 200 AMPS
>-I---,I~,-EMP occ-UPANcY 1·30 DA YSI +------
-l
TOTAL ElELTRICAL
------+-
-_ _J_ ___ _
_____ jj_
-f-
--------1----
~~A~~~CK FE~_ ---.P,~-¥-~,i---==::=~=----II __ San f_li~cp~f_ '/..1.;IC 80-9_2-24-0519 'l--: '?:i "')., -1
---A----'-----l~----~']f os·,+ . -----•~
_..,._ -----
.J""',..., --TQTA~
I
_ ___,__ . 'I I I lt-h~. d TOTAL FEES PAYABLE
-1-HAVE CAREFULLY EXA.MINEb'THE COMPLETED ··APPL!CATION ANO PERMIT' AND DO HEREBY Expiration. Every per_mi_t 1ssuedbytheBuUdlngOffici8I undertheprovisionsof'this ,t AN OSHI. PERMIT IS RE0UtREO FOR EXCAYA110NS OVER
CERTIFY UNDER PENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE Cod& shall 9l1Plf'ft by f,m.~ and become n~II and void. If the-building or work 5• o·• DEEP AND DEMOLITION OR CONSTRUCTION OF
~ u:
~
"' 0 C. E ~
I
-0 0
CJ
c "' .'2
°' C. .,:
I
-"' C a:
0 "' "' " "' <.,.
I
" .2 -" >-..
,;; "' " " 0 a:
"' ;;;
0
~
" " C "' C u:
-
C " " i3
0
0 " C. "' C
DECLARATIONS ARI; TRUE AND CORRECT ANO I FURTHER CERTIFY AND AGREE IF A PERMIT IS authorized ~y such ~rr:i,1t is not commenced w,thm 180 days fr~~ the date of such ·STAUC...,_,.,...,. OVER 3 STOAfES IN HEIGHT , permit, Of" 1f the bu1ld1ng or work authorized by such permit is suspended or · •~ ISSUED: TO COMPLY WITH ALL CITY, COUNTY AND STATE LAWS GOVERNING BUILDING CON-abandoned at an time after the work is commenced for a riod ol 1 . ..c
STRUCTION, WHETHER SPECIFIED HEREIN OR NOT. I ALSO AGREE TO SAVE INDEMNIFY AND , ., ~ PPRO DB ~
~
KEEP HARMLESS THE CITY OF CAFU,.SBAO AGAINST ALL u.('e1L1T1E~, -AJDGMENTS, COSTS ANO APPLICANTS SIGNATURE /If, ~OWNER CONTRAC I ORO ,~ y
EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE ~ ~ ' ~ ' B p ONE O /J
GRANTING OF THIS PERMIT. ,........._ ' ~~ J '\! y H • ~ ..... _..__,.._-'L -,
INSPECTION TYPE DATE INSPECTOR
BUILDING
FOUNDATION
REINFORCED S_IEEL
MASONRY
GUNITE OR GROUT
FLOOR & CEILING SUB FRAME
SHEATHING
FRAME
EXTERIOR LATH INSULATION
INTERIOR LATH & DRYWALL
PLUMBING
SEWER AND BL/CO
PLUMBING UNDERGROUND
PLUMBING TOP OUT
TUB AND ~HOWER PAN
GAS TEST
ELECTRICAL
TEMPORARY POWER
ELECTRIC UNDERGROUND
ROUGH ELECTRIC ------ELECTRIC SERVICE
BONDING
G. F. I. -SMOKE DETECTOR
MECHANICAL
DUCT & PLEM., REF. PIPING
HEAT -AIR COND. -SOLAR SYSTEMS,
VENTILATING SYSTEMS
CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATE
ITEMS ABOVE HA VE 86.EN APPROVED .. •·
JOB SITE FINAL •, • C
PLUMBING ' ELECTRICAL ' {/ . '
MECHANICAL ..... -'
GAS ' _ 111/P
BUILDING ' I •
SPECIAL CONDITIONS '
CERT OF OC 0ANCY ISSUED
.. . ,
FIELD INSPECTION RECORD
REQUIRED SPECIAL INSPECTIONS
INSPECTION REO IF INSPECTOR'S DATE CHECKED APPROVAL
SOILS COMPLIANCE
PRIOR TO
FOUNOA TION INSP
STRUCTURAL CONCRETE
OVER 2000 PSI
PRESTAESSEO
CONCRETE
r1 POST TENSIONED
CONCRETE
' . . FIELD WELDING
HIGH STRENGTH
BOLTS
SPECIAL MASONRY
PILES CAISSONS ·"
*·"" ' -
·. d#-1
-II
v·
--
-
-
-
-
.
-
. -
---. --
-
'• --' -
-
-
~ • • . .. .
• .. ~ .
INSPECTOR'S NOTES .
(-;;} ---· -"'61,Ahl:/J /,A,/ 71,JO S7Ag$ /)V,5 :z?:', y,,J
~ •~,($' JP 'f I~ vsEv ,:;."-.;:tA(l n£ 'TC>_
, --.. ,,.
I • '6--1") ~-,,, ·-... ~/ACS ---//_,,_;, /. --
• -$"£AA ---'IJV A..N/'r .,-,c,e,J.~-/('I ~ A,.,1,1
1--/J,€ J, I /1 I/ <L/f,,1/ ~ /H"L'.,/1 -/.rl"~ -"'• 'S) -fa') ,o, .... ~,t; ,,,_.c:;v-,.. ..... .. · -. S"?'V4&' .. ---~
I /'
,.,.J ---,,,Ml -IUT7 ~ -'f' ,r /I, --
-• •-•U/ ' -•,,-:,. --✓"~. 'S"f"i,tl) -~ , -,, /A/ "" L}/l, A/JuLfJ -n,A r . --,, AL . .,
-7,i; -~6.r ---.. Y,1111i< -:;;,a b,1,.;e_)
--AA'1 -,,, · c,7,-a/ hl./1'/, CA" -A:;.i(_---
-.Vo R,h,,-,r,A,~#1"..,.,;,_, e."'~.t? .Je4~ --~~----.. ------~-,,,1.~1-.J .=,,.,I -..-/,1. / ;r ,t.,e,;iLJ:,_L
-t/~,UAl t,k. ~II~~ Ci!' F'MM~ ,-.v.rJI: Gt!FTT~A-'r-, ,,e,,/,t~
-L --•---.-,_ , -
. ~.$. ~,CT • .
.
' ' -
. __. '·
.
.
~itp of ~!'Irl.Ubab . .
REQUEST FOR INSPECTION RECORD
~~
0 MASONRY
0 GROUT · GUNITE
0 FLOOR AND CEILING SUB FRAME
0 SHEATHING O ROOF O SHEAR
0 FRAME
0 EXTERIOR LATH
0 INSULATION
R LATH OR DRYWALL
D U
0 SEW PL/CO
0 TOP OUT PLUMBING
0 TUB OR SHOWER PAN
□ GAS TEST
0 WATER HEATER
~:WATER
8 ') cl l/ z TIME: ____ _
--=--...::IT:...__-__ l'-.<'---DATE: ~-2_-~l~I __
□ TEMP ICE
□ UFFER GROUND
0 ELECTRIC UNDERGROUND
□ ROUGH ELECTRIC
□ POOL BONDING
81c sERv1cE
□ SOLAR HEAT
□ PATIO
□ POOL □ SPA
0 SIGN
□ GRADING
SPECIAL INSTRUCTIONS_.J.£_1&,_-_:c\...l&all=....::J:cc._,:__;:__,_o,L_ ________________ _ •
Ready For Inspection: □ Monday
0 A.M. 0 P.M.
□ Wednesday □ Thursday D Friday
,
' QCitp of QCllrlshab
REQUEST FOR INSPECTION RECORD
<... BUILDING--.,,.)
0 FOUNDATION
D REINFORCING STEEL
0 MASONRY
0 GROUT -GUNITE
D FLOOR AND CEILING SUB FRAME
0 SHEATHING O ROOF D SHEAR
D FRAME
D EXTERIOR LATH
D INSULATION
0 INTERIOR LATH OR DRYWALL
' ~ --'AL
/"-._
PLUMBING
0 UNDERGROUND PLUMBING
D SEWER AND PUCO
D TOP OUT PLUMBING
D TUB OR SHOWER PAN
D GAS TEST
D WATER HEATER
D SOLAR WATER
D FINAL
Ready For Inspection: D Monday
D A.M. D P.M.
ELECTRICAL
D TEMPORARY SERVICE
D UFFER GROUND
D ELECTRIC UNDERGROUND
0 ROUGH ELECTRIC ~
0 POOL BONDING ~
D ELECTRIC SERVICE ~-/~//"
D FINAL ,Rt1"1llld,, C,
7-~-J,3
MISCELLANEOUS
D CONDITIONED AIR SYSTEMS
D SOLAR HEAT
D PATIO
0 POOL D SPA
D SIGN
D GRADING
D DRIVEWAY
D FINAL
D Thursday
1
□ Friday
CORRECTION NOTICE
'· . CITY OF CAijLSBAO,
BUILDING INSPECTION DEPARTMENT TIME: ______ _
INSPECTOR
\
BUILDING
D FOUNDATION
D REINFORCING STEEL
D MASONRY
D GROUT -GUNITE
D FLOOR AND CEILING FRAME
D SHEATHING
o FRAME
D EXTERIOR LATH
o INSULATION
o INTERIOR LATH OR DRYWAL
PLUMBING
o UNDERGROUND PLUMBING
□ UNDERGROUND WATER
o ROUGHT PLUMBING
o TOP OUT PLUMBING
□ SEWER AND PL/CO
o TUB OR SHOWER PAN
o GAS TEST
o WATER HEATER
ELECTRICAL
□ TEMPORARY SERVICE
□ ELECTRIC UNDERGROUND
o ROUGH ELECTRIC
o POOL BONDING
o ELECTRIC SERVICE
o UPPER GROUND
D G,F,L
o SMOKE DETECTOR
MISCELLANEOUS
D PLENUM AND DUCTS
D COMBUSTION AIR
D CONDITIONED AIR SYSTEMS
D SOLAR
D GRADING
D POOL
D PATIO
D SIGN
D OTHER
PHONE· 438-5525
Note: Final Inspection Required
2J'5"Jf-5S' t-VCl£~NA6-,4
DATE: 7-t-r-S
. .
'J) :>Fr r~,ed'IA/ ,e,,,<, w/11 v.£~1' 7'IJ #,2.v 41':f
1) -rtJ/1 /Wt 11!'4,<. CIJh14/I.CTl,u.J LIV .eA/J ?12"o/' -•
A~ dlllf7"' lie .FeAcoJt:4 A:iflJ Ct: ~
i) A'AAIM £ef, PVJ<) 5'?J AmJI' M't&'AKCI(_
f} /?L41./U/~ ll)Ap,!L A:IL 1/1.,<LJJ/4 Q()J;', ,?/Q
Aff,<; ~
. ; c/41 RI(. fe-i..Je,t<,, u~ 7
r
COMPLETE IN DUPLICATE AND POST WITH THE INSPECTION RECORD CARD
THIS IS TO CERTIFY THAT INSULATION HAS BEEN INSTALLED IN CONFORMANCE WITH THE
CURRENT ENERGY REGULATIONS, CALIFORNIA ADMINISTRATIVE CODE, TITLE 25, STATE
OF CALIFORNIA, IN THE BUILDING LOCATED AT:
SITE ADDRESS ~S:3 f 2.3 r"r' /.-we. ,'trl'l O.jq, s-1-. c .. ,{~
Number Street City
EXTERIOR WALLS
Manufacturer Owens Cornin~ Thickness/Type 31" R Va 1 ue 11
CEILINGS
Batts: Manufacturer Owens Corning Thickness/Type --'6~•-• __ R Va 1 ue -=.1.e,.9 __
No. Bags Blc,,,,n: Manufacturer ___________ Thickness/Type ___ _
Wt./Bag ________ Sq. Ft. Covered ______ _ R Value __ _
FLOORS
Manufacturer __________ Thickness/Type ____ _ R Value ___ _
SLAB ON GRADE
Manufacturer __________ Thic.kness/Type ____ _ R Value ___ _
Width of Insulation ____ Inches
FOUNDATION WALLS
Manufacturer ____ _ Thickness/Type ____ _ R Value ___ _
GENE~y CONTRACTOR Sc_,,c,ck J..ttC, LICENSE NUMBER ____ _
BY ,.Jh_.1/.L/, TITLE __,_(.,c..li-w.:;_· ..;;,.J~P.=".W:~--DATE zjcJPJ
INSULATION CONTRACTORDana Johnson Insulation, Inc. LICENSE NUMBER 306493
BY _________ _
Bl Form #121
22175
TITL£Authorized Representati,oi\TE _______ _
------. . .. -----------------
!32-&.L/?
_1!l 5d
ESGII,. CORPORATION
0320 CIIEMAJ>EAKE nn .. MlllT .. ~ 122
SAN DIEGO, CA 9212B
(T14) 560·140~
;)55~ /.::>..._:J-J f/Ct 01 'Y/t:LiC{
e t
Citp of Carlsbab
Jl;III SDICT ION'-----,----DATE Pf 18 2
L l.l t::lt:J<N~ 't'.f/
PLAN CORRECTION SHl!!!T
PlAn ChPCk No. 82·'24-
r·,t.-plans r-iccived by
''H• t•lana received by
~ate 1n1tial plan check
f'l'IRCl~<'IID I PLEASE READ
jurhdiction 7{;e ~ 10
plan checke/»GJJ ft/II
c0111p l eudftZ / by ~ "4 f/3 -
r lan check is l1~ited to technical requi rement•
c~nta1ned in the Uni form 8uildin9 Code, Unifor•
Plumb1n9 Code, Uniform Mechanical Code , National
Electrical Code and 1tate laws re9ulatin9 ener9y
conservation, noi1e attenuation and access for
the handicapped. The plan check i1 ba■ed on
re9ulation1 enforced by the Duildin9 Inspection
04partment. You may have other correction■
based on law1 and ordinances enforced by the
Plannin9 Department, En9ineer in9 Department
or other department,.
The itc•• circled below need clarification, aodification or chan9e. All circled item• have
tc be 1ati■fied before the plan■ will be in
conforaance with the cited code■ and re9ulation■•
Per Sec. 303 (cl, 1979 Unifora Buildin9 Code, the approval of the plan■ doe■ not permit the
violation of any ■tate, county or city law.
ill!:!
Plea1e uke all corrections on the ori9inal
trac in91 and 1ubfflit two new 1et1 of print,,
and any ori9inal plan 1et1 that may have
been returned to you by the jurisdiction,
wr n~ ,11 1c:.. c ''-'"~r '1o rJ .:: a'~
'"fu1Q <:j C?T$ &T Th€' @4 -G'),.>YI~~
To facilitate recheckin9, please identify, next to each circled item·, the ■heet of
the plan■ upon which each correction on
thi■ sheet ha1 been made and return thi1
check 1heet with the revi1ed plane.
D APPLICANT COPY
D CITY COPY
D PLAN CHECKER COPY
1-----4-------------·
1----6------------. ____ .. _ -·--------
10} -~ ~-OIL-t3tJ_, fl.£.M,E-I-«)~
A-• o/'E<-r;o,J DIV-~t-<a • ,4..)J>c...h. rw-o
G_,u.,~4!>.
PLAN CORRECTION SHEE'l'
--.........,__
SINGLE FAMILY AND DUPLEX DWELLINGS
Plan Check No. \~ 2,-'Z,4-J /
Date plans received by jurisdiction MO• "11 l"Z.
~ate plans received by pi'a°n checker 1Ul; · 1 j 1 "?>
Date initial plan check completed S'v TV by~
FOREWORD: PLEASE READ ~
Plan check is limited to technical requirements
contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy
conservation, noise attenuation and access for
the handicapped. The plan check is based on
regulations enforced by the Building Inspection
Department. You may have other corrections
based on laws and ordinances enforced by the
Planning Departme nt, Engineering Department
or other departments.
The items circled below need clarification,
modification or change. All circled i tems have
tc be satisfied before the plans will be in
conformance with the cited codes and regulations.
Per Sec. 303 (c), 1979 Uniform Building Code,
the approval of the plans does not permit the
v iolation of any state, county or city law.
., . PLANS \ --
Please make all corrections on the
tracings and submit two new sets
and any original plan sets that y have
been returned to you by the jur ·sdiction,
tO: I~
D APPLICANT COPY
D CITY COPY
D PLAN CHECKER COPY /
0~ i..e-tta" 1>cm, w:. o M t_ wr , '3
ubmit fully dimensioned plot plan drawn
o scale showing location size, and use
fall existing and proposed structures
on t he lot. Identify property l ines and
show lot dimensions and all easements.
Show location of all cut or fill slopes
and approximate finish floor elevations
for all structures and show elevations at
all corners. Sec. 3021b)7.
~Indicate distance from center-line of street
or alley to property line and distance from
cur h to property line. Sec. 302(b)7
«/Plans, specifications and calculations shall
/" be signed by a California State licensed
engineer or architect. (California
Business and Professions Code)
D. FIR~ PROTECTION
-~ Walls closer t han /~· s hall be one-hour
have no openings,
parapets when the
1,000 square feet
Sec. 17091a)
3 feet to property lines
fire-rated construction,
and shal ave 30 inch
buildi floor area exceeds
floor. (Table 5-A
.--('Projections, incl ing eaves, may not extend r• ~ore than 12 in es into the 3 foot setback
from the prop y line. Sec. 1710 and
Sec. 504(b)
,..,,-;rojectio , including eaves,shall be one-r · ~our fi -resistive construction , heavy
timber r of non-combustible material if
they roject into the 3' setback area from
the roperty line. Sec. 1710
ow location of perm~ne~y 'Ared smo~ etcctor. Sec. 1210 "TO ()'t-,S.~\
ROOM SIZES (,IGHT VENTILATIONS ANO GLAZING
One room must contain a minimum of 150 square
feet of superficial floor area. Sec. 1207(b)
/,1abitable rooms, other than kitchens, shall
co ntain at least 70 square feet of f loor
area. Sec. 1207(b)
~Window area must ~eat l east 1/10 of the
floor area and a minimum of 10 square feet
per Sec. 1207(a). Appears to be deficient
in
,/Openable window area must be~/ { of the ,?'°" floor area and a minimu~ of 5 quare feet.
In bathrooms, laundry rooms d similar
r ooms. Minimum i s 1.5 sq.f • (Sec.1205(a)
✓-':one-half of all required
be openable in
,/nrovide mechanical ve tilation capable of
/" ;roviding five air c nges per hour in
bathrooms , water cl et compartments, laundry
rooms and s imilar if required windows
are not provided. l 205la)
other than a kitchen,
7'0" in any dimension.
U~GS.
/show ceiling height for laundry rooms,
hallways, corridors, and bathrooms is a minimum of 7'0". Sec. 1207(a)
drails shall satisfy th allowing:
/4 Provide 30" clear width for water closet
compartments and 24" clearance in front
of water closet. Sec. 1711( (
,/ No cooking room shall be sed for sleeping /J• purposes, unl ess comply· gas an efficiency
living unit. Sec. ·12
Provide handrail for tairways over 30"
high whe serving single dwelling.
Title 24, Sec. T2 22(b)
'L!;.AHandrail hall 30" to 34" above the r~ noaing o tree . Sec. 3305(jl ~
Handrail cting from a wall shall N
--~pecify safety glaz·ng for glazing in hazardous )"'· ~ocations such as lass doors, glazing
adjacent to such oors and glazing adjacent
to walking surf es. Sec. 5406
/Glazing in sh er and tub enclosures (including w dews) shall be tempered,
laminated o approved plastic.
Sec. 1711 l (gl
or
es and cornices may not project into
required yard more than 2 inches for each ot of yard width if required windows
pen into the yard. Sec. 1206(d)
A mez zanine is an intermediate floor and
may not have a floor area exceeding 33 1/3
percent of the total floor area in the room
below, and the mezzanine floor must have
a clear height of 7 feet, above and below,and
must have 651 of the long side open to the
room below.
4.Y.:The loft you show does not comply as a r· mezzanine floor and is, by Building Code
D.
definition, a story _____________ _
EXITS 1 STAIRWAYS, AND RAILINGS
Floors above the second story shall have not less than 2 exits. Sec. 3302(a)
4y."Required exit doon,ays shall be not l s
/ than 36" in width and not less tha •-a•
i ~ height, and shall be capable o opening
at least 90 degrees. Sec. 3303 )
•~ovide 36" high protective for 7· ~~rches, balconies, and op sides of landings.
Maximum opening between r lings shall be
less than 9". Sec. 1716
/show how guardrail con ection details are
adequate to support 2 pounds per lineal
foot at a right angl to the top rail .
Table 23-B
d landing details.
8" and minimum run is 9".
room is 6'-6".
have as ac not less than 1 1/2" betwe ® the wall a the handrail. The han g ip portion of handrail shall
be not ie s than l 1/4" nor more than
2" in er s-sectional .dimension.
Sec. 33 (j) (see attached)
-~very stairway ~ng__,s~ve a dimension,
_,,7'· ~easured in the direction of travel, at
least equal to the stairway width.
Sec. 330S(gl
~/A door may open over a stairway landing r· provided the door, in any position, does
not reduce the clear area of the landing,
in the direction of stairway travel, to
leas than one-halt the required width of
the stairway. Sec. 3305 (g)
/. door may open inward at the top step of
a stairway provided the top step is not more than 7 1/2" lower than the floor level.
Sec. 3303(i)2 y Provide details of winding stairway.·
a. Minimum tread is 6 inches at any point
and minimum 9 inches at a point 12 inches
from the side of the stairway.
b. Maximum rise is 9 inches.
c. Minimum width is 30 inches.
(see attached)
Sec. 3305(dl
SY, Provide spiral stairway details:
/ a. Minimum run is 7 1/2 inches at a point
from where the tread is the narrowest.
b. Maximum rise is 9 1/2 inches.
c. Minimum headroom is 6 feet 6 inches.
Sec. 3305(f)
(see attached)
s/. Spiral stairways may not be uaed for required
/' exits when the area served is greater than
400 sq. ft. Sec. 3305(fl
7
Spiral stairways must have a clear walking
space of 26 inches between the column and
handrail . Sec. 3305(f)
Provide I.C.B.O. Reasearch Report and Number
for metal stairway, or submit plans and
calculations and approved fabricator
registered with the Building Department
or note that the stairway fabrication shall
be done under special inspection per the
approved fabrication plans. Sec. 306(a)4B
and Sec. 306(f)
In buildings over 2 stories in height, provide
3/4 hour fire-rated assemblies for all openings in the exterior wall below or within
10 feet horizontally of an exterior stair-
way. An exit balcony with 2 separated
stain,ays is exP.mpt. Sec. 3305
~/Exterior stairways shall not project into
/
0 ~he 3 foot setback from the property lines.
Sec. 3305(nl
•,
E. I ROO ING
• Garages are not permitted to open into
a room used for sleeping purposes. Sec. 1104 ~,✓ Openings between carport and residence 7'· require self-closing doors and stationary
windows. Sec. 1214
1~ Show garage framing section, size of header r-· over garage opening, lateral cross bracing
at plate line and method of bracing garage
front. Chapter 23
NOTE: Minimum plywood diaphragm ratio is
1/2 to l or 2'8". Table 24-I
ecify roof material and
Specify I.C.B.O. approval
materials not covered i
. 1"o ~ 'Ff 12.~ • Doors between dwellings and attached garages
io~ ?-C2~ ,w ~ t ay swing in either direction provided
for roof 'll.'1'1-~~ ~ he difference in floor elevation between
.,..-12Q.11vt"Q the dwelling and garage does not exceed
~ Specify roof slope
to support accumu ed water.
T_Show roof drai and overflows. Sec. 3207(a)
/Provide skyl' ht details to show compliance
with Secti s 3401 and 5207 or provide ICBO
approval mber.
Provide fireplace construction details r
note construction to be per attached fireplace
standard drawing. Sec. 3707
7 1/2 inches and provided the door is not
used as the primary means of egress from
the building.
If the difference in floor elevation exceeds
7 1/2 inches, or if the door is used aa
the primary means 0.5,; egress from the building,
additional steps r landing must be provided
in accordance h stairway requirements,
and the do must not swing over the depressed
el . ee 3 3 o 3 ( i ) 2 and 3 3 O 5 ( g) •
e 18" raised platforms for any FAU,
er heater, or any other device which
ay generate a flame or spark.
Not& tMtt conti.nuoua fire wall protection
shall be installed behind raised platform(sl
prior to framing platform.
R. FOUNDATION R~QUIREMENTS
,..>-1(" Note on plans that"A soils engineer shall
/ .. • eva-1 uate any unanticipated uncompacted fill
or expansive soil or other soil problems
disclosed during construction". Sec.306Ca)l2.
Show veneer support and connections comply 1/submit soils classification determination
with Sec. 3002, 4,5,6, and Sec. 2516(a) /-by a licensed engineer or architect based
regarding t i es and t9 wire in horizontal on observation, tests, borings, or excavations,
joints or note construction to be perattached and containing comments on the degree of
sheets 30-1 or 30-2. expansiveness, compressibility and bearing
,/ y.:alue. Sec. 2905 ,JI!· Show height and construction details of ~ 11 masonry walls. Chapter 24 ote on the plan the soils cl sification,
whether or not the soil is · pansive, and
ote that cleanout openings shall be"provided note the allowable beari value. Sec. 2905 at the bottom of all cells to be grout filled
over 4' in a single pour. Cleanout shall l The foundation plan
be sealed before grouting, after inspection. 6 e soil report rec ,,/ Sec. 2415 ~ P oject ____ _,,,._ ___________ _
./1· Show floor and roof connections to masonry iO, \~
walls. Connection shall resist 200 pounds 'L->t ,
per lineal foot or the actual design load, '\
whichever is greater. Sec. 2310 j.
gJ Provide material specifications for morta , ;,'l
/-grout, masonry and reinforcing steel. ·~ U1
A ec. 2403 :'\"'
how how masonry house wa 11 s retaining ear h l9 \
, /re to be waterproofed. Provide detail. ?· ~ote that special inspection of the masonry will be required for _____________ _
G. GARAGE AND CARPORTS
~arage requires one-hour fire protection ,-·;~ the garage side of walls and ceilings
c ommon to the dwelling. Table 5-B Sec.503(b)
1~11 elements supporting floor above garage
,-·to have one-hour fire-resistive protection
on the garage side. Sec. 503. Beams and
posts, not within the wall or ceiling c on-
struction, must comply with UBC, Table 43-A,
or be minimum 6" dimension beam and minimum s• by 8 • post.
not on the foundation plan listing
eport recommendations for foundations.
uilding pad preparation.
Note on the ·foundation plan that "Prior
to the Contractor requesting a Building
Department foundation inspection, the
soils engineer shall advise the Building
Official in writing that:
l. the building pad was prepared in accor-dance with the soils report:
2. the utility trenches have been properly
backfilled and compacted, and:
3. the foundation excavations, forming
and reinforcement comply with the soils
✓ report and approved plan."
Provide spread footings for concentrated
loads designed for 1,000 PSF soil bearing
or per bearing value as determined by
an engineer or architect. Chapter 29
yt; She~ height of all foundation walls.
~-A. Show height of retained earth on 7 · walls. Chapter 23 r· Show distance of foundation
cut or fill slopes and show
heights of cuts and fills.
TABLE NO. 29-A-F UNDATIONS FOR STUD BEARING.
WALLS-MINIMUM REQUIREMENTS
Ot"N OF
FOUNDATION
WIDTM TMICIINtsS ltLDW
IIUMltl TMIClllltU OF OF OF NlTUUl
FOUIIDlTIDII WlU FOOTINS FODTIIII SUUlCl OF
STDIIH (IIICMI) (IIICIIII) (IICIIII) OF QIIOUND lllD FINISN
CONClm UNIT QlllDt
MASOIIIT (lllellel)
1 6 6 12 6 12
2 8 8 15 7 18
3 10 10 18 8 24
XOTES:
\\'Mtt unwual condition• or frost conditions are found, footincs and
foundations shall be as requirtd in S~ion 2907 (al.
The ground under the Boor may be Hcavated to the ele,·ation of th•
top of the footina.
Show foundation sills to be pressure treated,
or equal. Sec. 25l7(c) 3.
Show foundation bolt size and spacing.
Sec. 2907(el
Specify size, ICBC number and manufacturer
of power driven pins. Show edge and end
distance and spacing. Sec. 306(fl
Show size, imbedment and location of hold
down anchors on foundation plan. Sec. 23l2(f)
Note on plan that hold down anchors must
be tied in place prior to foundation inspection.
Sec. 23l2(fl
Show adequate footings under all shear
walls. sec. 23ll(e)
Show stepped footings for slopes steeper
than 1:10. Sec. 2907(c)
Show minimum 18" clearance from grade to bottom of floor joists and minimum 12"
clearance to bottom of girders. Sec. 2517
Show pier size, spacing and depth into
undisturbed soil. Table 29-A
Show minimum under floor access of l 8"x 24".
Sec. 2517
Show minimum under floor ventilation equal
to l 1/2 sq. ft. for each 25 lineal feet
of exterior foundation with openings as
close to corners as practicable to provide
cross ventilation on at least two approximate-
ly opposite s ides. Sec. 2517
I. FRAMING
Show all joists, rafters, beams, and posts
2" to 4" t hick to be No. 2 Grade Douglas
Fir-Larch or better. All posts and beams s• and thicker shall be No. l Grade Douglas
Fir-Larch or better. (Table 25-A-l l
,~✓Note cross bridging or blocking. Floor 7· joists and rafters more than 12" in depth
and spanning more than 8 feet shall be
supported laterally by bridging at intervals
not exceeding 8 feet. Sec. 2506(gl
Jr·
1,;J.
Y"' · 1,)§. y9.
~o.
Ji.
✓i.
Show blocking at ends and at supports
of floor .joists, and for rafters at exterior
walls. Sec. 2506(gl
Show solid blocking at ridge line and
at exterior walls on trussed roofs.
Sec. 25061g)
Show double joists. Floor joists shall
be doubled under bearing partitions running
parallel with the joists. Sec. 2518(d) S
Show rafter ties. Rafter ties shall be
spaced not more than 4 feet on center
where rafters and ceiling joists are not
parallel. Sec, 2518(hl
Show rafter purlin braces to be not less
than 45 degrees to the horizontal. Sec. 25181h)
Show 1/2" minimum clearance between top
plate of interior partitions and bottom
chord of trusses. (To ensure loading
will be as designed.)
Show double top plate with minimum 48"
lap splice. Sec. 2518(gl4
Show nailing will be in compliance with
Table 25-P.
Provide fire stops between stories, between
top story and roof space, at ceilings
and floor levels in interior and exterior
walls , in mansard roof or eyebrow so no
concealed or furred space is greater than
10' horizontally or vertically, between
stair stringers at top and bottom and
between studs along and in line with
stair run adjoining stud walls and partitions,
at perimeter of sliding door pockets,
between chimney and wood frame using metal
or incombustibles for the fire stop and
at other places that could afford passage
of flame. Sec. 2517(f)
Show stud size and spacing. Maximum allow-
able stud heights: 2"x4"@ 16" is 14 ';
3"x4"'2"x6"@ l6"o.c. is 20'. Sec. 2518(g)2
Note an A.I.T.C. Certificate of Compliance
for glued laminated wood members shall
be given to the Building Inspector prior
to erection. Sec. 306(fl
Detail all post to beam and post to footing
connections . Sec. 2517(cl 4
Specify nail size and spacing for all
shear walls, floor and roof diaphragms.
Indicate required blocking. Maintain
maximum diaphragm dimension ratios.
(Tables I,J,K).
Show 3"x4" or 2"x6" studs in first story
of three story building. Sec. 2518(fl
Provide truss details and truss calculations.
Provide roof framing plan. Sec. 302(a)7
Provide framing sections through ______ _
Section 302(al 7
Specify all header sizes for opening over
4' wide. Sec. 2518(g) 7
Provide calculations for
Section 302(a) 7
In areas subject to water splash and in exterior locations, wood columns and posts
shall be supported by piers projecting Show wall bracing. Every exterior wood
stud wall and main cross partition shall
be braced at each end and at least every
25 feet of length with lx4 diagonal
let-in brace or equivalent. Sec. 2518(g)S I at least 2" above the finished grade and
shall bear on a metal base plate or treated
wood unless the columns or posts are foun-
dation grade redwood or cedar. Sec. 2Sl7(c)4
209.
Show access to the attic
furnace to be minimum 30
inches. Sec. 708, 709
or space between
and loor above in excess
Se . 2517
/
the attic furnace
and have continuous
leas than 24 inches
Note that passageway
shall be unobstruc
solid flooring
gr de and panel indenti-/
able 25-J
s less than 3:12, design
Sec • 2 5 18 ( h )
'~cod shear walls shall not be used to
/
0
;esi st horizontal forces contributed by
maso nry in buildings over one story in
height. Sec. 2516(b)
./Gypsum l ath and plaster, gyps\1111 sheathing r 9
· board and gypsum wal l board shall not be
used in vertical diaphragms tor · t
forces i mposed by masonry or crete
construction. Table 47-I
·/If cripple wall studs a less than 14", ,?U-raming shall be soli locking. Sec.2518(g)
Cripple wal l studs ceeding 4 feet in
he i ght shall be 3 nch by 4 i nch or 2
i nches by 6 inc s when supporting 2 ries.
Sec. 2 18 (g)6 t
Show ywo sheathing over ex sed eaves,
or ot er ather,exposed are , is exterior
grade ec. 2517(g) 3
Show a weep screed at foundation plate
line on all ;xterior ud walls to be
tuccoed. s,c. 47 el
Provide an appr d waterproof building
per under siding. Sec. 170l(al
ecify an approved flashing for exterior~A penings and parapet walls. Sec. 3208 I'\
how corridor width to be minimum 36".
ec. 3304(b) ~
r,/Specify truss layout for 30" x 30" attic '(!I
/M'·,,ccess.
Ridges, hips, and valleys shall be at
east one size larger than supported
rafters. Sec. 2518(h) 3
Provide metal straps across ridge beam
a nd rafters.
J. MECHANICAL
All heati ng, venti lating, and cooling systems
and appli ances shall compl y with the Uniform
7-nical Code.
Show the size, location and type of all
heating and cooling appliances or systems.
~Jf. Show source of c ombustion air for furnace r• will comply with Chaper 6, U.M.C.
~/... Every dwelling uni t shall be provided_ with
)"' heati ng facilities capable of maintain-
i ng a room temperature of 7 0° F. at 3
f eet above the floor in all habitable
rooms. Show basis for compliance. use
Sec. 1211
Show minimum 30" deep unobstructed working
space in f ront of furnace.
Note on plans,clearances to be per manufac-
turers l isti ng. Sec. 70 UMC
under any
210.
✓
wide. Sec 708
Show permane electrical outlet and
lighting fi ure controlled by a switch
for the at c furnace. Sec. 708 UMC
Show det ls to comply with Section ~09
for fur ce under the floor, Sec tion 708
for at c furnace, or Section 710 for
oof outside furnace.
Note on plan, gas vents and non-combustible
g passing through three floors or
·shall be effectively draft stopped
each floor or ceiling. UBC Sec. 1706(al6
K. ECTRICAL (National Electrical Code)
All wiring shall comply with the National Electrical
h
:· Note _on the plan the amperage of electrica•/4')
service. 't:!,..J
If the electrical installation is more
than 200 amperes, show panel location
and provide a single line diagram and
load calculations including:
a. Wiring method employed.
b. Sizes of all conductors, switches,
c.
d.
e.
circuit breakers, fuses, and conduits.
Approximate length of service feeders.
Provide plot plan showing services,
all panel locations, circuit arrangement
and load distribution on panel buaaes.
Provide typical panel schedule(sl .
Dwellings req~ire minimum ·100 amp service.
Show location of all electrical receptacles.
Electrical receptacle locations and/or
spacing is not adequate in '$;:::g ~N · ev:vo eMc..Los:.~.4 s;.e, s e...-J s .
At least one receptacle shall be installed ~
outdoors, in basements and attached garaget_:!7
other than laundry outlets . Art. 210-25(b)
Show minimum dwelling lighting (NEC
Art. 210-26(a) and GFI'S in §'ara2~• bath~
and outdoors. NEC Art. ~16-!a1. ----. Note "UFER" ground (NEC).
Art. 250-81
All plumbing shall comply the Uniform
ng Code.
Show water heaters· e, type and
location on plans.
Show method of pr viding combustion air
to fuel burning ater heater. Sec. 1307
Fuel combustio water heater shall not be
installed in b th or bedroom or i n a c loset
opening into th or bedroom. Sec. 1309
protect wa ter
Sec. 13'10
heater and /l . ,./)
~rge line to e xteri ~1)~l arr··
vent to outside. UMC 1)1V
-l>f'lLIL..Jcw.+--a n-~ hose bibbs and l awn
rinkl r systems shall have approved
prevention devices. Se c. 100 3
ower stall shall accomodate a 30"circle
h ea minimum floor a r ea of 900 sq.in.
9 9(dl
(DUPLEXES)
arty) walls
o achieve /} TC ) rating -~
an Impact /
ing on floor/
Title 25
y.E:NERGY CONS RVATION
All ad it ns to existing residential
buildi must comply with Title 24
energy regulations. Additions exceeding
30l of the existing building requires the
existing and addition to have R-19 ceiling
insulation if the existing ceiling area
is accessible for insulation installation
(T20-l40l(c).
p-t: Specify the insulation R valves for walls,
roof and ceiling. (R-11 for walls: R-19
for ceilings, or provide details and analysis
_ _/for alternate design. T20-1403 Table A, 2B.
)'3· Specify the gross floor area or heated
portions of the dwelling, and the area
of glazed openings on the plan. (T20-1430)
Provide an analysi s justifying increasing
the single glazed area beyond 161 of the
gross floor area. Show method to redu
heat loss to that which would occur w· h
basic glazing. (T20-l402,def.)
Provide energy analysis to show th the
bonnet capacity of the gas centra furnace does not exceed the building des · n heat
loss by more than 301. (Except 'ons:
48,000 BTU Hr. output furnace. See also
California Efficiency Adjust nt.) T24-l404
• M.o.ee en pla
plenums, and fi
se ducts,
of HVAC system
re sensitive
tape or mastic air loss. T20-l404
conform to UM
. Note on plan oors and windows
nconditioned areas
striped per ANSI
to the exteri
shall be ful weath Standard. ( 20-1403 •
6) . .bl.<-..-.m--trlCl!l'l',f...f,lw.&. b k draft dampers are
I all fan systems exhausting build' g. T20-l403
:/ Electrical
not be use
a. 60\ of
by a n
b. supple
c. less
d. life
T20-l
esista ce space heating shall
unles heatin /cooling is supplied
ndeple able source.
ents heat pump system.
an 10 of total heating system. cle c st analysis justifies.
4
all heating and cooling
equipment e ciencies shall conform to Title 20-Chapter 2, Subchapter 4, Article 4.
!7Sl for forced air furnaces).
~-Note on plan that no natural gas, central
heating plant may be installed without
✓-an Intermittent Ignition Device. T20-l405
Elec~ric resistance water heating is not
permitted unless verfied as cost effective
by a life cycle cost analysis. T20-l406
~
Q.:.
301.
Outdoor pools with fossil fuel heaters
require pool covers as well as other energy
saving devices such as time clocks, etc.
T20-l406
under the
comply with
o 3/4" copper pipes must be installed
from water heater location to convenient
location of future solar panels (City Ord.)
Provide sleeves (roof jacks) in roof for
two future 3/4" copper pipes to cunvenient
location of future solar panels (City Ord.)
Note that solar water piping is to be insulated
in areas that are not heated or cooled.
(City Ord.) y See attachment for roofing requirements.
The plans were reviewed baaed on the information 1hown on
the plans. If the plans are in error, or changed during
construction, the permittee shall contact the Building
Department for review and prior approval before proceeding
with the work:
0 Building plans are substantially correct
and complete.
By: _________________ _
Date: __________________ _
0 Building plans would be substantially correct
and complete if minor corrections are made
at counter.
By: __________________ _
Date: __________________ _
Building plans require major corrections
complete plan recheck, by plan check
::~in~reG~ets ~IA-~
Date: ') \ \'l, \~k
and
If you have any questions regarding this plan check, please
call -::f1M at1\f..L '5(oO 14'.i)/
We ~ould also be pleased to meet with you, at no charge, if
additional assistance is needed.
~---::;=.:tEPTACLE SPACING AT SLIDI!JG GLASS DOORS
1
l .. A floor type receptacle shall not be required in any traveled portion of a
sliding glass door opening.
~ Sliding glass doors , 12 feet in width or greater, with no fixed panels, shall
have a receptacle placed on each side within 6 feet of the opening. Other
receptacles wil~ be_ eJ_en~J_spaced throughout the room.
3. A sliding glass door with fixed panels shall not require floor receptacles in
the traveled pathway of the sliding portions . Floor outlets placed within
12 inches of the wall at the fixed glass locations are acceptable in lieu of
wall outlets. ' ..
4. Fi~ed glass walls are subject to Arti;le 210-25 (b) and floor receptacles
wi:hin 12 inches of the wall are acceptable.
·••ca .
6' -0" MAX. 6'-0" MA.X. ,,._
~•...::>-J=? MOUN TE::)-' tD f.
I 6-Q-FLOOR MOUNTED
..
'
Lr ..
I
6'-0''MAX.
FIXED I FIXED
7 :s '
"-MORE THAN 6 '-0" _..,
6'-0"MAX. ~
1
6'-0"MAX.
►
I
FIXED I FIXED
I
(::_ LESS THAN s·-o .. -·
6'-0"MAX.
i
~ 7
®
® 1 .,
FIXED ,$ I
AN✓ SIZE 3 6'•0"MI e LESS THAN
MOUNTEDl
I
6'-0" MAX .
6':-0"
>\ I
7 -=Y » I
C ___ c_~FIXED-MORE THAN 2-4"
6'-0" MAX. 1 6 '-0" MAX.
ANY s,zk =7
6'-0" MAX.
,.
I
6'-0" MAX. i
CIXED•MORE THAN 24" qtl9 FLOOR MOUNTED
z I
(____ANY SIZE
l~ 6'-0" MAX.
~ I SUDERS -ANY SIZE
6'-0"MAX.
FIXED FIXED
I --)
"---LESS THAN 6'-0".====:7
I. 1
<U>
l
I ESGIL CORPo'RATIONJ EC -203(2 of 2)]
Th e following are requirements for outlet spacing1
1.There shall be no point on the walls between the arrows·
morL• than six from a receptacle.
2.A receptacle is required for any wall space 24" or wider .
J .The wall space afforded by fixed room dividers shall be included
in the 6' measurement on both sides . Dividers may be solid or open.
4.The fireplace is considered to extend 12" on each side of the firebox.
5 .For fixed glass panels and sliding glass doors in exterior walls
sheet 1. 6 .Receptacles spaced per 1 and 2 above are required, except at steps,
along the floor line of sunken rooms where elevation change exceeds 8"
To determine the location of a receptacle outlet, the measurement is to be made
a long the floor line of the wall and is to continue around corners of the room,
but is not to extend across doorways, archways, fireplaces, passageways, 6r other
space unsuitable for having flexible cord extended across it.
I ...,,
ARCHW~
GREATER THAN 8"
STEPS J
RECEPTACLE SPACING I N BEDROOMS
This ~all less than
3 ' no receptacle;
more than 3'
receptacle required
Th 1s wall less than
2' no receptacle;
more than 2'
receptacle required
J ·"-,
I I
ESGIL CORPORATION
9320 CHESAPEAKE DRIVE, SUlTE 122
SAN DIEGO, CALIFORNIA 92123
DWELLING LIGHTING AND GROUND -FAULT PROTECTION INFORMATION 78 N.E.C.
Sec. 210 • 26 (a). Lighting outlets are
mandatory in dwelling occupancin
0 I ...... ,., ------'
In all dwelling occupancies. one-family
houses, two-family houses, apartment
houses, dormitories hotels, motels, etc.
A. At least one wall-switched lighting
outlet must be installed in every
habitable room,
bathroom,
hallway,
stairway
attached garage, and
at each outdoor entrance
( OU tdoorl igh ts).
8. At least one wall-switched or pull
chain lighting outlet must be
installed in every
attic,
underfloor space,
utility room, and
basement used for storage or
containing equipment requiring
servicing.
Exceptions: Portable lamp
Receptacle
S.c. 210 • 8 (al. Ground-fault protection
required for rHidantial outdoor, garaga,
and bathroom recaptacl■1
At least ona
receptacle in an
attached garage
S.c. 210 • 25 (bl. Receptacle outlets
are required outdoor,, In basement, and
in attached garage of a one f,mlly dwelling,
in addition to any provided for laundry
equipment
Lighting
outlets with GFI protection
In receptacle or ahead
Lighting outlet
required at
every outdoor
entrance of
dwelling-type
occupancie,
of It -------.J
One or more GFI devices (GFI CS, GFI
receptacle, ate.) required for personnel
proter.tion for all 120-volt, single-phase,
15-amp and 20-amp receptacle outlets
installed in the following location in
residential occupancies:
1. bathrooms
2. outdoors
3. garages
Exception: Ground fault circuit pro•
tection need not be provided on receptacle
outlets located in a garage provided such
outlets are single and are intended for use
with fixed or stationary appliances.
GFICB
in panel
/'-...
At least one receptacle 1.,,,,,.---~ I
in a basement--C., _____ .J
At least one receptacle outdoors for one•
family dwelling• with GFI protection in
receptacle or ahead of It
SEC. 300 4. Wiring through wood
framing membars In exposed and
conc-■led locations
If BX, NM cable, or raceway wiring
(rigid conduit, EMT, etc.) is used
through holes bored in joists, rafters
or similar wood members ...
Upstairs
bathroom
Downstairs
bathroom or
lavatory
Outdoor
receptacle
Cable (BX, NM, etc.) may be run in
notch in wood member, but a steel
plate 1/16 in. thick must be used
over notch to protect cable from
nails, etc.
1. Wall-switched receptacle(s) may be used
instead of a lisht1ng outlet in habitable
rooms Other than kitchens and bathrooms.'
GFI receptacle with
feed-through protection
of all load-side receptacles Upstairs
bathroom
Cable wiring (BX, NM,
etc.) through holes
bored in studs must be at center of
face and not less than 1 1 /4" from
the nearest edge ...
· 2. In :iallways. stairways, and at outdoor
entrances, remote control or automatic
co,.,trol of light1ng shall be permitted .
Section 210-~Glbl At least one wall-
switch-controlled light1ng outlet or
wall-switch-cont rolled receptacle shall
be installec in guest rooms of hotels,
motels, and similar occupancies.
Conventional CB
or fuse in ~anel
Conventional
receptacles
Circuit capacity available
for lighting and other
receptacle loads
.. ,if hole is less than
1 1 /4" from the nearest
edge, a steel plate 1/16 " thick must be
used 10 protect caole against driven nails
or screws.
1979 EDITION UNIFORM BUILDING CODE
Sec. 3305.
(j) Handrails. Stairways shall have handrails on each side, and every
stairway required to be more than 88 inches in width shall be provided
with not less than one intermediate handrail for each 88 inches of required
width. Intermediate handrails shall be spaced approximately equal within
the entire width of the stairway.
EXCEPTIO~S: I. Stairways 44 inches or less in "idth and ,rair"a~s ser,·-
ing one individual dwelling unit in Group R, Di,ision I or 3 O.:.:upancie, may
ha,e one handrail, except that such stairways open on one or l:,oth side< <h:ill
ha,e handrails provided on the open side or side,.
I 2. Pri,ate stairways 30 inches or less in height may ha,e handrails on one i side only.
Handrails shall be placed not less than 30 inches nor more than 34
inches above the nosing of treads. They shall be continuous the full length
of the stairs and except for private stairways at least one handrail shall ex-
tend not less than 6 inches beyond the top and bottom risers, and ends
shall be returned or shall terminate in newel posts or safety terminals.
Handrails projecting from a wall shall have a space of not less than 11/z
I inches between the wall and the handrail. The handgrip portion of hand-
rails shall be not less than I¼ inches nor more than 2 inches in cross-sec-
tional dimension and shall have a smooth surface with no sharp corners.
1~·M1~.
• N
0
,~·
1l'!•toz• MIN.
a~•"'ax.
NOT
ACCEPTABLE
COPY
COPY
o~ swr, 3 D PLAN CHECKER
Citp of Carlsbab
(Y~~e.s
~ $20.. I (..
@co~~ l>~\~ /;P. Submit fully dimensioned plot plan drawn
to scale showing location size, and use
of all existing and proposed structures
on the lot. Identify property lines and
show lot dimensions and all easements.
~a,~ ~u~--no--l S•-h...~
LA-Co~-nq (Y)(?a .. ,i) 0 1..0 ~v -,,d· :L .Sei ,1..,.~
JURISDICTION: ____ ....... ___ DATE '71 I ~I 82.
PROJECT ADDRESS: 2..$?2/i;s ~UG\~~ r
To: A-9~ 1,.. , '-e N ,-
PLAN CORRECTION SHEET
SINGLE PAMILY AND DUPLEX DWELLINGS
Plan Check No. 8 2-'Z-4-J
Date plans received by jurisdiction MO • '11 l"Z-
:>ate plans received by plan .checker 1v ~ · 1 / ! '}
Date initial plan check completed Su rJ by~
FOREWORD: PLEASE READ ~
Plan check is limited to technical requirements
contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy
conservation, noise attenuation and access for
the handicapped. The plan check is based on
regulations enforced by the Building Inspection
Department. You may have oth~r corrections
based on laws and ordinances enforced by the
Planning Department, Engineering Department
or other departments.
The items circled below need clarification,
modification or change. All circled items have
to be satisfied before the plans will be in
conformance with the cited codes and regulations.
Per Sec. 303 (cl, 1979 Uniform Building Code, the approval of the plans does not permit the
violation of any state, county or city law.
f
~
Please make all corrections on the original
tracings and submit two new sets of prints,
and any original plan sets that may have
been returned to you by the jurisdiction,
tC: "'BL;>G, I ""l)~
To facilitate rechecking, please identify,
next to each circled item, the sheet of
the plans upon which each correction on
thi s sheet has been made and r eturn this
check sheet with the revised plans.
Show location of all cut or fill slopes
and approximate finish floor elevations
for all structures and show elevations at
all corners. Sec. 302(bl7.
Indicate distance from center-line of street
or alley to property line and distance from curh to property line. Sec. 302(b)7
/Plans, specifications and calculations shall ✓-be signed by a California State licensed
engineer or architect. (California
Business and Professions Code)
D. FIR~ PROTECTION
'~ Walls closer than 3 feet to property lines
/~· shall be one-hour fire-rated construction,
have no openings, and shall have 30 inch
parapets when the building floor area exceed■ 1,000 square feet on any floor. (Table 5-A
Sec. 1709(a)
/:rojections, including eaves, may not extend more than 12 inches into the 3 foot setback
from the property line. Sec. 1710 and
Sec. 504(b)
• .,,,,-;rojections, including eaves,shall be one-
)"· ~our fire-resistive construction, heavy
timber or of non-combustible material if
they project into the 3' setback area from the property line. Sec. 1710
Qshow location of perm~y ~red smo~ detector. Sec. 1210 1 o U"c-S..~\
~-ROOM SIZES1 LIGHT1 VENTILATIONS ANO GLAZING
·,/one room must contain a minimum of 150 square
/'· feet of superficial floor area. Sec. 1207(b)
Aiabitable rooms, ~ther than kitchens, shall
contain at least 70 square feet of floor area. Sec . 1207(b)
~Window area must ~eat least 1/10 of the
floor area and a minimum of 10 square feet per Sec. 1207(al. Appears to be deficient in
~~penable window area must be 1/20 of the /°" floor area and a minimu~ of 5 square feet. In bathrooms, laundry rooms and similar
rooms. Minimum is 1.5 s q.ft. (Sec.1205(a)
~One-half of all required window area must be openable in _____________ _
,/nrovide mechanical ventilation capable of ✓· ~roviding five air changes per hour in
bathrooms, water closet compartments, laundry rooms and s imi lar rooms if required windows
are not provided. Sec. 1205(a)
1y: No habitable room, other than a kitchen,
/ · shall be less than 7'0" in any dimension.
~C. 1207(c)
✓. Show that ceiling height for habitable
rooms is a minimum of 7'6". Sec. 1207(a)
,
,,
/~how ceiling height for laundry rooms, hallways, corridors, and bathrooms is a
minimum of 7 '0". Sec. 1207(aJ
/4 Provide 30" clear width for water closet
compartments and 24" clearance in front
of water closet. Sec. 17ll(bJ
/
Handrails shall satisfy the following:
a. Provide handrail for stairways over 30"
high when serving a single dwelling. Title 24, Sec. T25-22(bJ A Handrail shall be 30" to 34" above the
no■ing of treads. Sec. 3305(jJ
,/. No cooking room shall be used for sleeping
/'~. purposes, unless complying as an efficiency
living unit. Sec. 1208
·-~pecify safety glazing for glazing in hazardous ,Y· ~ocations such as glass doors, glazing
adjacent to such doors and glazing adjacent
to walking surfaces. Sec. 5406
/c1azing in shower and tub enclosures
(including windows) shall be tempered,
l aminated or approved plastic.
Sec • 1 711 ( f J ( g J
Sleeping rooms shall have a window or
exterior door for emergency exit. Sill
eight shall not exceed 44" above the floor.
~~1 he window must have an openable aree of
.ll~~ t least 5.7 square feet with the minimum IJ,~ 1 penable width 20" and the minimum openable ~f ,fZ(,'\' height 24". Sec. 1204
{!· AVEaves and cornices may not project into 7· ~ required yard more than 2 inches for each
foot of yard width if required windows
open into the yard. Sec. l206(dJ
LA mezzanine is an intermediate floor and ;r-· may not have a floor area exceeding 33 1/3
percent of the total floor area in the room
below, and the mezzanine floor must have
a clear height of 7 feet, above and below,and must have 65\ of the long side open to the
room below.
4VThe loft you show does not comply as a r· mezzanine floor and is, by Building Code defi nition, a story _____________ _
D. EXITS, STAIRWAYS, ANO RAILINGS
Floors above t he second story shall have
not less than 2 exits. Sec. 3302(a)
o/,Required exit doorways shall be not less
/ than 36" in wi dth and not less than 6"-8"
i~ height, and shall be capable of opening
at least 90 degrees. Sec. 3303(e)
'~ovide 36" high protective railing for 7 · ;~~ches, balconies, and open sides of landings.
Maximum opening between railings shall be
less than 9". Sec. 1716
/show how guardrail connection details are
adequate to support 20 pounds per l ineal foot at a right angle to the top rail.
Tabl e 23-8 e Provide stairway and landing details.
Sec. 3305 (b) & (cl
a.
b.
c.
Maximum ri se a• and minimum run is 9".
Minimum head room is 6'-6".
Minimum width is 30".
7 Handrail projecting from a wall shall
have a space not less than l 1/2" between
the wall and the handrail. The hand grip portion of handrail shall
be not less than l 1/4" nor more than
2" in cross-sectional ,dimension.
Sec. 3305(j) (see attached)
•~very stairway ~ng~ve a dimension, /· ~eaaured in the direction of travel, at
least equal to the stairway width. Sec. 3305(gJ
~/A door may open over a stairway landing r· provided the door, in any position, does
not reduce the clear area of the landing,
in the direction of stairway travel, to
leas than one-half the required width of
the stairway. Sec. 3305(gJ
/. door may open inward at the top step of
a stairway provided the top step is not
more than 7 1/2" lower t han the floor level. Sec. 3 30 3 ( i) 2
y. Provide details of winding stairway."
a. Minimum tread is 6 i nches at any point
and minimum 9 inches at a point 12 inches from the side of the stairway.
b. Maximum rise is 9 inches.
c. Minimum width is 30 inches.
(see attached) Sec. 3305(dl
sj/. Provide spiral stairway details:
/ a. Minimum run is 7 1/2 inches at a point
from where the tread is the narrowest.
b. Maximum rise is 9 1/2 inches.
c. Minimum headroom is 6 feet 6 inches.
Sec. 3305(fJ
(see attached)
sJI; Spiral stairways may not be used for required
/ exits when the area served is greater than
400 sq. ft. Sec. 3305(f)
Spiral stairways must have a clear walking
space of 26 inches between the column and handrail. Sec. 3305(f)
Provide I .C.8.0. Reasearch Report and Number
for metal stairway, or submit plans and
calculations and approved fabricator
registered with the Building Department
or note that the stairway fabrication shall
be done under special inspection per the
approved fabrication plans. Sec. 306(al48
and Sec. 306(fl
5_},; In buildings over 2 stories i n height, provide / 3/4 hour fire-rated assemblies for all
openings in the exterior wall below or within
10 feet horizontally of an exterior stair-
way. An exit balcony with 2 separated
s tairways is exP.mpt. Sec. 3305
~/Exterior stQirways shall not project into
)I"' ~he 3 foot setback from the property lines.
Sec. 3305(n)
I'
The walls and soffits of the enclosed usable ~owl 3/e• solid core self-closing door
space under interior stairs shall be protected for openings between garage and dwelling.
on :he e~cl~sed side as required for one-h@ur Sec. SOJ(dl
re-resisti~f construction.v .. /ec.,..3305(ml •~ Garages are not permitted to open into i1-<!..,\1,o -rJl\\\<312.S . '-".llJ d:C,<:2.,\,nc1 y->• a room used for sleeping purposes Sec 1104 nunum construction specifications shall t 7-· ·
be made a part of the approved plans. l • Openings between carport and residence
(See attached) require self-closing doors and stationary
I!!. ROOFING
~
pecify roof pitch.
. Roof pitch is not adequate for roof type
specified. Specify minimum pitch of ----::===:::::...
windows. Sec. 1214
lo,<(" Show garage framing section, size of header r-· over garage opening, lateral cross bracing
at plate line and method of bracing garage
front. Chapter 23
NOTE: Minimum plywood diaphragm ratio is
1/2 to l or 2•e•. Table 24-I
. . . . 1"o ~ ~lll.'i! • Doors between dwellings and attached garages Specify roof material and appllcatio~ ~~~•2..0(lt ay swing in either direction provided
Specify I.C.B.O. approval number for roof ~*n-,.~ ~ he difference in floor elevation between
materials not covered in UBC. ~Q~ the dwelling and garage does not exceed
'~/ . . . -...__,,..__.,,..-7 1/2 inches and provided the door is not /"'· Specify roof slope for drainage or design used as the primary means of egress from
to support accumulated water. Sec. 3207(a) the building.
y.:show roof drains and overflows. Sec. 3207(a) If the difference in floor elevation exceeds
/Provide skylight details to show compliance 7 1/2 inches, or if the door is used aa
with Sections 3401 and 5207 or provide ICBO the primary means of egress from the building,
approval number. additional steps or landing must be provided
~Provide plastic roof panel details to show
/ .. compliance with Section 5206 or provide
ICBO number. ? Show attic ventilation. Minimum vent area
is 1/150 of attic area or l/300 of attice
area if at least 501 of the required vent
is at least 3 feet above ceiling joists.
Sec. 3205(c) P·
in accordance with stairway requirements,
and the door must not swing over the depressed
el. (see 3303(i)2 and 3305 (g).
vide 18" raised platforms for any FAU,
water heater, or any other device which
may generate a flame or spark.
Note that continuous fire wall protection
shall be installed behind raised platform(a)
prior to framing platform.
8. rMASONRY ff. FOUNDATION RE IREMENTS 7 Provide fireplace construction details or Note on plans that•A soils engineer shall
note construction to be per attached fireplace eva-luate any unanticipated uncompacted fill
standard drawing. Sec. 3707 or expansive soil or other soil problems
_L disclosed during construction•. Sec.306(a)l2.
P· Show veneer support and connections comply 1/.submit soils classification determination
with Sec. 3002, 4,5,6, and Sec. 2516(a) /--by a licensed engineer or architect based
regarding ties and t9 wire in horizontal . on observation, teats, borings, or excavations,
joints or note construction to be per11tt11ched and containing comments on the degree of
sheets 30-1 or 30-2. expansiveness, compressibility and bearing
/ ~alue. Sec. 2905 ,II'!· Show height and construction details of ll masonry walls. Chapter 24 ote on the plan the soils classification,
whether or not the soil is expansive, and Note that cleanout openings shall be·provided note the allowable bearing value. sec. 2905 at the bottom of all cells to be grout filled
over 4• in II single pour. Cleanout shall Th• foundation plan does not comply with
be sealed before grouting, after inspection. 6 e soil report recommendation for this
/ Sec. 2415 fl( p eject
./1 · Show floor and roof connections to masonry }~ .I~\~ ;L------------------------wal ls. Connection shall resist 200 pounds '..I"\ .1t""
per lineal foot or the actual design load, '\ f
whichever is greater. Sec. 2310 ~} 2 Provide notes on the foundation plan listing
:/
v, the soils report recommendations for foundations.
Provide material specifications for morta , ~ slab and building pad preparation. grout, masonry and reinforcing steel. \A-<(\
ec. 2403 :'\• l Note on the foundation plan that "Prior 1. \ to the Contractor requesting a Building how how masonry house walls retaining ear hu, Department foundation inspection, the
re to be waterproofed. Provide detail. soils engineer shall advise the Building
Note that special inspection of t he masonry Official in writing that:
will be required for______________ l. the building pad was prepared in accor-
G. GARAGE AND CARPORTS
~rage requires one-hour fire protection
_,..--~~ the garage side of wal ls and eeilings
common to the dwelling. Table 5-B Sec.503(b)
l~ll elements supporting floor above garage
,--~o have one-hour fire-resistive pr otection
on the garage side. Sec. 503. Beams and
posts , not within the wall or ceiling con-
s truetion, must comply with UBC, Table 43-A,
or be minimum 6" dimension beam and minimum
a• by 8" post.
dance with the soils report:
2. the utility trenches have been properly
backfilled and compacted, and :
3. the foundation excavations, forming
and reinforcement comply with the soils
✓ report and approved plan."
Provide spread footings for concentrated
loads designed for 1,000 PSF soil bearing
or per bearing value as determined by
an engineer or architect. Chapter 29
/
y<;: Show height of all foundation walls. Chapter 23
';-,I{_ Show height of retained earth on all foundation ✓-· walls. Chapter 23
1/e. Show distance of foundation to edge of ✓-cut or fill slopes and show steepness and
heights of cuts and fills. Chapter 29
17'. Note on plans that wood shall be 6" above ~ finish grade. Sec. 24l7(cl 7.
13 . Note on plans that surface water will d~
away from building and show drainage pattern ' iE. and key elevations. Sec. 2905 ( f) 1 ,,
1
"' <,
Tl. Dimension foundation per Table 29A. V
I.
TABLE NO. 29-A-FOUNDATIONS FOR STUD BEARING.
WALLS-MINIMUM REQUIREMENTS
DU•TN OF
WIDTN TNICIIN[SS FOUNDATION
111111110 T111CIIIIHS OF llLOW
OF FOUNDATION WAU OF FOOTINC OF NATUUL
STOlllS FOOTINC SURF&Cl
(IICNII (IIICIIU) (IICNI) OF UOUND AND FINISN
CONtlm UNIT UUl MAS~ (IIICMI)
1 6 6 12 6 12
2 8 8 15 7 18
3 10 10 18 8 24
!\OTES:
\Vbett unwual condition.• or frost conditionJ att found. footinp and foundlltions sh.all M as requirNI in Stttion 2907 (a).
11,e llff)Und under the ftoor may M rxc:avated to thr eJr,.ation of th~ lop of the footin11.
Show foundation sills to be pressure treated,
or equal. Sec. 2517(c) 3.
Show foundation bolt size and spacing.
Sec. 2907(e)
Specify size, ICBO number and manufacturer
of power driven pins. Show edge and end
distance and spacing. Sec. 306(f)
Show size, imbedment and location of hold
down anchors on foundation plan. Sec. 2312(f)
Note on plan that hold down anchors must
be tied in place prior to foundation inspection. Sec. 23l2(f)
Show adequate footings under all shear
walls. Sec. 23ll(el
Show stepped footings for slopes steeper than l:l0. Sec. 2907(c)
Show minimum 18" clearance from grade to bottom of floor joists and minimum 12" clearance to bottom of girders. Sec. 2517
Show pier size, spacing and depth into undisturbed soil. Table 29-A
Show minimum under floor access of 18"x 24". Sec. 2517
Show minimum under floor ventilation equal
to l 1/2 sq. ft. for each 25 lineal feet
of exterior foundation with openings as
close to corners as practicable to provide
cross ventilation on at least two approximate-
ly opposite sides. Sec. 2517
FRAMING
Show all joists, rafters, beams, and posts
2" to 4" thick to be No. 2 Grade Douglas
Fir-Larch or better. All posts and beams
5" and thicker shall be No. l Grade Douglas
Fir-Larch or better. (Table 25-A-l)
Show wall bracing. Every exterior wood
stud wall and main cross partition shall
be braced at each end and at least every
25 feet of length with lx4 diagonal
let-i n brace or equivalent. Sec. 2518(g)5
,~✓Note cross bridging or blocking. Floor 7· joists and rafters more than 12" in depth
and spanning more than 8 feet shall be
supported laterally by bridging at intervals
not exceeding 8 feet. Sec. 2506(g)
~-
r· Yo·
;r·
~-
1;J.
v-,.
vfi. y9.
Show blocking at ends and at supports of floor .joists, and for rafters at exterior
walls. Sec. 2506(g)
Show solid blocking at ridge line and at exterior walls on trussed roofs.
Sec. 2506(g)
Show double joists. Floor joists shall
be doubled under bearing partitions running
parallel with the joists. Sec. 2518(d) 5
Show rafter ties. Rafter ties shall be
spaced not more than 4 feet on center
where rafters and ceiling joists are not
parallel. Sec. 2518(h)
Show rafter purlin braces to be not less than 45 degrees to the horizontal . Sec. 2518 (11)
Show l/2" minimum clearance between top
plate of interior partitions and bottom
chord of trusses. (To ensure loading will be as designed.)
Show double top plate with minimum 48"
lap splice. Sec. 2518(g)4
Show nailing will be in compliance with
Table 25-P.
Provide fire stops between stories, between
top story and roof space, at ceilings
and floor levels in interior and exterior
walls, in mansard roof or eyebrow so no concealed or furred space is greater than
10' horizontally or vertically, between
stair stringers at top and bottom and
between studs along and in line with
stair run adjoining stud walls and partitions, at perimeter of sliding door pockets,
between chimney and wood frame using metal
or incombustibles for the fire stop and
at other places that could afford passage
of f lame. Sec. 2517(f)
Show stud size and spacing. Maximum allow-able stud heights: 2"x4"@ 16" is 14';
3"x4"&2"x6"@ 16"o.c. is 20'. Sec. 2518(gl2
Note an A.I.T.C. Certificate of Compliance
for glued laminated wood members shall
be given to the Building Inspector prior
to erection. Sec. 306(f)
Detail all post to beam and post to footing
connections. Sec. 2517(cl 4
Specify nail size and spacing for all
shear walls, floor and roof diaphragms.
Indicate required blocking. Maintain
maximum diaphragm dimension ratios. (Tables I,J,K).
Show 3"x4" or 2"x6" studs in first story of three story building. Sec. 2518(f)
Provide truss details and truss calculations.
Provide roof framing plan. Sec. 302(al7
Provide framing sections through ______ _
Section 302(al 7
Specify all header sizes for opening over
4' wide. Sec. 2518(g) 7
Provide calculations for __________ _
Section 302(al 7
In areas subject to water splash and in
exterior locations, wood col umns and posts
shall be supported by piers projecting
at least 2" above the finished grade and
shall bear on a metal base plate or treated
wood unless the columns or posts are foun-
dation grade redwood or cedar. Sec. 2517(cl4
•'
~-Show draft separation for attic areas
in excess of 3,000 sq.ft. Sec. 3205
1 Q✓ Show draft separation for space between T' dropped ceilings and floor above in excess
of 1,000 sq.ft. Sec. 2517
Specify plywood grade and panel indenti-
fication index. Table 25-J
',/ When roof pitch is less than 3:12, design
/' • ridge as a beam. Sec. 2518 (h)
209.
/
Show access to the attic or under floor
furnace to be minimum 30 inches by 30
inches. Sec. 708, 709 UMC
Note that passageway to the attic furnace
shall be unobstructed and have continuous
solid flooring not less than 24 inches
wide. Sec 708 UMC
210. Show permanent electrical outlet and
lighting fixture controlled by a switch ✓ for the attic furnace. Sec. 708 UMC
21A"'. Show details to comply with Section ~09 7·· for furnace under the floor, Section 708
for attic furnace, or Section 710 for
,..........--:ood shear walls shall not be used to j) roof or outside furnace. ✓· ;esist horizontal forces contributed by 12 Note on plan, gas vents and non-combustible
masonry in buildings over one story in piping passing through three floors or
height. Sec. 2516(b) less shall be effectively draft stopped
Gypsum lath and plaster, gypsum sheathing at each floor or ceiling. UBC Sec. 1706(al6
board and gypsum wallboard shall not be .
used in vertical diaphragms to resist K. ELECTRICAL (National Electrical Code)
forces imposed by masonry or concrete All wiring shall comply with the National Electrical _.....,--construction. Table 47-I ~e •
.,),'10 • ;f cripple wall studs are less than 14", 22 . Note on the plan the amperage of electrical raming shall be solid blocking. Sec.2518(gl6 ,-11/ service.
Cripple wall studs_exceeding_4 feet in /''-~ If the electrical installation is more
~eight shall _be 3 inch by 4 inch or 2 . y~-than 200 amperes, show panel location
inches by 6 inches when supporting 2 stories. and provide a single line diagram and
Sec. 2518(gl6 load calculations including:
a. Wiring method employed • • Show plywood sheathing over exposed eaves, b. sizes of all conductors, switches,
or other weather exposed areas, is exterior circuit breakers, fuses, and conduits.
grade. Sec. 25171gl 3 c. Approximate length of service feeders.
Shov a weep screed at the foundation plate d. Provide plot plan showing services,
line on all exterior stud walls to be all panel locations, circuit arrangement
tuccoed. Sec. 4706(el and load distribution on panel busses.
e. Provide typical panel schedule(sl. Provide an approved waterproof building ~
per under wood siding. Sec. 17011a) 2 Dwellings req~ire minimum 100 amp service.
ecify an approved flashing for exterior ~
2
_
5
• Show location of all electrical receptacles.
penings and parapet walls. Sec. 3208 Electrical receptacle locations and/or
how corridor width to be minimum 36 •. spacing is not adequate in ?(:::pf 3,.A:N
ec. 3304(bl f,NO e,v,c .. Los:.r,;i, cl §'&,S e_:( S
Yspecify truss layout for 30" x JO" attic ;P· At least one receptacle shall be installed
ccess. outdoors, in basements and attached garages,
idges, hips, and valleys shall be at other than laundry outlets. Art. 210-25(bl
east one size larger than supported Ji! Show minimum dwelling lighting (NEC
rafters. Sec, 2518(hl 3 Art. 210-26(al and GFI'S in rara29, baths
19Y.Provide metal straps across ridge beam ft ~doors_ NEC lt"rt. ~IO-!al.
/ and rafters. ,· 22 . Note "UFER" ground to be provided (NEC).
J. MECHANICAL Art. 250-81
All heating, ventilating, and cooling systems
and appliances shall comply with the Uniform
Me;.?4nical Code.
,,)f'O· Show the size, location and type of all
heating and cooling appliances or systems.
~,.,(. Show source of combustion air for furnace J"1
• will comply with Chaper 6, U.M.C.
,/.... Every dwellir¥:! unit shall be provided_ with .JI"~ heating facilities capable of maintain-
ing a room temperature of 70° F. at 3
feet above t he floor in all habitable
rooms, Show basis for compliance. UBC
Sec. 1211
Show minimum 30" deep unobstructed working
space in front of furnace.
Note on plans,clearances to be per manufac-
turers listing. Sec. 704 UMC
Furnace shall not be installed under any
stairway. Sec. 704 UMC
Furnace shall not be installed in any
bedroom, bathroom, closet, or in confined
s pace wit h access only through such room,
unles s s pe cified as direct vent appliance,
enclosed furnace or electric heating appliance.
Sec. 704 UMC
b, PLUMBING (Uniform Plumbing Code)
All plumbing shall comply with the Uniform ?.ing Code.
Show water heater size, type and
location on plans.
Show method of providing combustion air
to fuel burning water heater. Sec. 1307
Fuel combustion water heater shall not be
installed in bath or bedroom or in a closet
opening into bath or bedroom. Sec. 1309
Provide adequate barrier ~o protect water
heater from vehicle damage. Sec. 1310
Show T and P valve on water heater and
show route of discharge line to exterior
Sec. l007(el
Provide dryer vent to outside. UMC
Sec. 1903
Note on the plan that hose bibbs and lawn
sprinkler systems shall have approved
backflow prevention devices. Sec. 1003
3!iuw rcso dpptcoal fut pzcfab fitepl&e~ ~
aod pnwi.de.,..ppsanrali it11tt,:sl:latlon 1nstructiona-,,
at jch she. ~-Q.a..,yt.,~ -:-
Shower stall shall accomodate a 30"circle
and have a minimum floor area of 900 sq.in.
UPC 909(d)
NOISE INSULATION (DUPLEXES)
Show details of duplex common (party) walls
and floor/ceiling assemblies to achieve
a Sound Transmission Class (STC) rating
in walls of 50 decibles and an Impact
Insulation Class (IIC) rating on floor/
ceiling of 50 decibles. Title 25
Show how penetration of assemblies for
piping, electrical devices, recessed cabinets,
bathtubs, soffits, or heating ventilating,
or exhaust ducts shall be sealed, lined,
or insulated to maintain required sound
/.
transmission rating. Titre 25
Provide insulation in walls and ceiling
to achieve STC of SO between garage and
living area if garage use is not controlled
by resident Title 25. y. ENERGY CONSERVATION
All additions to existing residential
buildings must comply with Title 24
energy regulations. Additions exceeding
301 of the existing building requires the
existing and addition to have R-19 ceiling
insulation if the existing ceiling area
is accessible for insulation installation
(T20-l40l (cl.
~ Specify the insulation R valves for walls, roof and ceiling. (R-ll for walls: R-19
for ceilings, or provide details and analysis
_ _/for alternate design. T20-1403 Table A, 2B.
j,7J• Specify the gross floor area or heated
portions of the dwelling, and the area
fJ·
:>'-
of glazed openings on the plan. (T20-l430)
Provide an analysis justifying increasing
the single glazed area beyond 161 of the
gross floor area. Show method to reduce
heat loss to that which would occur with basic glazing. (T20-l402,def.)
Provide energy analysis to show that the
bonnet capacity of the gas central furnace
does not exceed the building design heat loss by more than 301. (Exceptions:
48,000 BTU Hr. output furnace. See also
Ca lifornia Efficiency Adjustment.) T24-1404
Note on plan that all tranverse ducts,
plenums, and fitting joints of KVAC system
shall be sealed with pressure sensitive
tape or mastic to prevent air loss. T20-l404
Note on plan that insulation of ducts shall
conform to UMC Section 1005. (T20-l404)
Note on plan that all doors and windows
to the exterior or to unconditioned areas
shall be fully weather striped per ANSI
Standard. IT20-l40J).
Note on plan that back draft dampers are
required on all fan systems exhausting air from the building. T20-l403
Electrical resistance space heating shall
not be used unless:
a . 60\ of heating/cooling is supplied
by a nondepletable source.
b. supplements a heat pump system.
c. less than 10\ of total heating system.
d. life cycle cost analysis justifies.
T20-l404
Note on plan that all heating and cooling
equi pment efficiencies shall conform to Title 20-Chapter 2, Subchapter 4, Article 4.
(75\ for forced air furnaces).
Note on plan that no natural gas, central
heating plant may be installed without
/-
an Intermittent Ignition Device. T20-l 405
Elec~ric ~esistance water heating is not
permitted unless verfied as cost effective
by a l ife cycle cost analysis. T20-1406
~
o.
301.
302.
Outdoor pools with fossil fuel heaters
require pool covers as well as other energy
saving devices such as time clocks, etc. T20-1406
MISCELLANE·ous
Show a minimum 2" air space and flashing
between planter and building walls. Sec. 2517(e)
Specify material to be used under the
shower tile. Sec. 1707(a)
Specify lath and plaster to comply with
Chapter 47, UBC.
Two 3/4" copper pipes must be installed
from water heater location to convenient
location of future solar panels (City Ord.)
Provide sleeves (roof jacks) in roof for
two future 3/4" copper pipes to cvnvenient
location of future solar panels (City Ord.)
Note that solar water piping is to be insulated
in areas that are not heated or cooled. (City Ord.)
See attachment for roofing requirements.
The plans were reviewed based on the information shown on
the plans. If the plans are in error, or changed during
construction, the permittee shall contact the Building
Department for review and prior approval before proceeding
with the work:
0 Building plans are substantially correct
and complete.
By: ________________ _
Date: __________________ _
0 Building plans would be substantially correct
and complete if minor corrections are made
at counter.
By: _________________ _
Date: -------------------
Building plans require major corrections and
complete plan recheck, by plan check
engin~ required.
By: ~ G \ L-~ " I A N.
Date: '] \ \'7, \9 k
If you have any questions regarding this plan check, please
call -:::rlW\ at11+-L S"(oO 14'.0,)
We would also be pleased to meet with you, at no charge, if
additional assistance is needed.
□ Bldg. Dept.
VALUATION AND PLAN CHECK FEE
PLAN CHECK NO.
BUILDING ADDRESS c; t; -~ t:,.; ,; L V C \ 8 2.. l\....l "I='}
APPLICANT/CONTACT -re'S) &0 \... Y) l !)(={;_,:} PHONE NO. 4-72 l q 4 \ I
BUILDING OCCUPANCY \Z.-;> l,!)ve \0f..) DESIGNER PHONE _____ _
TYPE OF CONSTRUCTION t;'-(\) CONTRACTOR PHONE
~ SIG\Y\eA S -----
BUILDING PORTION BUILDING AREA VALUATION VALUE
MULTIPLIER
L ,v \f'v ~ I Aoo '<' J '/-... L~t ~ l l.o 9 20 0
'
Lc:.-UA---O~ ~ .. 4-G,7--J. 2. -./... I zoo I I 06 0 0 '
Air Conditioning
Commerc i al --
Residential I Boo Y--:.2-~ ,z tµJ 9G::>4-0 -I
Fire Snrinklers
Total Value , 88)9ze,
Building Fermi t Fee ___ ....,GJ .... !? ___ 5_,....,5..._0=------
Plan Che ck Fee ______ 4...:;•.....::tfa:;;...;:ao:;...;.'..:.;LO::;...._ ____ _
C Ort.M EN TS l --------------------------
PHILIP HENKING l!IENTON
P"ESIOl:NT • CIVIL ENGINEU,
Schrock, Inc.
1865 Moreno Boulevard
San Diego, California 92110
BENTON ENGINEERING. INC.
APPLIED SOIL MECHANICS -FOUNDATIONS
111140 RUFFIN ROAD
SAN DIE GO, CALIFORNIA 92123
October 26, 1982
Subject: Project No. 82-10-22M
Moisture Contents in Subgrade Soils
Lot 200 of La Costa N.eadows Unit No. 1
Carlsbad, California
Dear Mr. Schrock:
ON~ (7 14 ) !18!1-1118!1
This is to report the results of tests to determine the moisture contents of the soils in the
upper three feet below finished grade in the proposed building area at the subject site in
Carlsbad, California. ·
The soil samples we re obtained on October 25, 1982 and the results of the moisture determinations
are presented as follows:
Approximate Location
of Samples
Northeasterly portion of proposed building area
Southwesterly portion of proposed building area
Depth Below
Existing Grade
in Feet
1.0
2.0
3.0
1.0
2.0
3.0
Moisture
Content
{% dry wt)
16.8
16.3
14.8
17.6
16.3
9.6
It is concluded from the field observations of the various soil types and the final results of the
moisture determinations that the soils in the upper three feet below finished grade at the locations
sampled have been sufficiently moistened to minimize the potential expansion of the soils, as
recommended in our report under Project No. 70-10-28D dated October 12, 1971.
It is recommended that positive drainage, 6 inches of vertical fall in 6 feet horizontally, should
be provided around the perimeter of the house in landscaped areas. Drainage systems should also
..
Schrock, Inc. -2-October 26, 1982
Project No. 82-10-22M
be prov'ided to collect all runoff from roofs and conduct the water in watertight pipes either into
the streets or storm drains. Al I surface drainage should be prevented from ponding adjacent to or
running over the tops of slopes. Inlet boxe_s and watertight pipes should be installed when necessary
to comply with the above requirements.
Respectfully submitted,
BENTON ENGINEERING, INC.
By -t'R:~ ~ac•~t"t-R.C. Remer
~ /} 'Gl Reviewed by -· w ~
Phil~iv1f~neer
RCR No. 10332
Distribution: (3) Addressee
RCR/PHB/jr
BENTON ENGINEERING, INC.
... !
-••/ I
□CMTOl·J ,-l~CINU-.1.:lhJt:;, INC.
I OUNl)ATIUN!i
6°/.St t I ( A •ut./ 1'()111 t VAUD
bAl,1 IHI t,, I "I If -.,td,:IA 112115
.. HILIP H,.Nl(l~G U! r-HOII
Ptt1•1ntfi'IT . C,:IVH, l""""'1hll " O,..lc ,!,l.r 12, 19/i
Rancho le Cc-:.lo
r..outc 1, Box 25!JO
Cncinitos, Ccllfor11la 92024
Subject:
Gentli:r,1cn:
P1.:>jcct No. i'0-10-~:UD
County P,mnit No. L37[b
Interim f{cp.:>rton Conir1,c.l _ I r ill -:d Ct,)UJlJ
And Clc;sificc.tion of $,:,ii Ctndltion~
Lots 1 to W-t, inclu!.ive, H:5 1-., 18?, in -:.IL ... ivc
192 to 253, in :h,siv..?, 1.1i1,l c~rt<1in ~t,u .. l Arcw
Le., Costa i\kc.J~w:. U,1it t~·,. 1
Son Dico-> County, Cul ifom ia
!,AN 01P ,.n ~"·'•~h.,. l A. M• YA.• 4t,~#-!..t,L,4
This i, h> report the results of k:.I~ cind d 1~...:rvutio11S 1,1,,~lu in orclc-r 1,1 ln:;pcct tLu Lornpocti~n
of filled gr.:iur,d ploc.ed on ce:rtnin t:11:m of l ol:; l lo 5, indusive, 9 I\.) 15, i11r:l,,~.iv11, 23 h> :.;.1,
inc:lusiv~, 55 lo 5'), inc.lu .. ivu, 61, l.-1, {i/ Iv 72, i11t.lu:.ive, 75 to 91, inclusiv.!, 10,t to J(JJ,
Inclusive, 112 to 119, lncludvc, 121 t,> 1~4, inclu:.ivo, 160, li'3 to 181l, lnclu.;ivu, 106 lo 13?,
inclusive, 1~2 to ~18, incluwivtJ, 2~0, ::·,:1, 222, 2.:.:.~, 231, 232, 233, 237 lo 24/, inclusivo,
and portions c,t Unlcomlo Strc-!t, Alga l:Jcd, lucit.Jniu~'J St,:.:ot, Luduinoyu I luco, Alismo
Street, Antilcpo Streat, /.,bcjono Stic1Jt, G,ullo Strcut, Pc1sa Street, Unicornio V/ay, Unicornio
Place, Unicornlo Court, Unicornio SlrLct, Av0 D..?I Poraiso Street, Abedul Street, ALcdul Place,
and Zodiac St1e.:?t in La Co~ta /\\ouJow:. U,)it l·fo. 1, San Diogo County, Californic. Tests were
also taken In soils placccJ us bu<.!dill ov~r utili,ly line:. in Unit No. l and in coinpact<:d filled
grountf plocrd on Lots 466, ~6'/, 1:k',u, 4lN, c,nd 470 llf Lo Co:.i·a Meadows Unit l~o. :.:t. Compac-
ting of fil IE:d uround has not Ut.:cn com;il,•tt,cJ on Lot 1 ~·:!> end tho results of finol le:.t·:. and impuc-
tlons on this lot will bo includeJ in our fi11ol l(:p,1rt en thh unit. The fills on Unit t-Jo. 1 1e:purtcd
herein we,c plo~ec.J during tho pcrioC: b ,lrn:·on Novcn,l.h.:r Y, 1970 ond Scplc11,Lcr 20, 1?71.
Tho opproximcto areas om.I c,_.r,t l,s of fillc-J u1our,cJ pluct:cl under our inspection in.occorclancc with
the approved spccificoticns urn shown 011 1111.: c.11tod1 ~d U,awing No. 1, entitled "Location of
Corr:poctcd fill1.:J GrounJ,11 ll,c !.Jiuuina j'lt111 11'.,t.;J lor the plocemc11I of filled u1ound was
prepared by l,ick Enginccrina Compcmy 011J lmt rovis1,;J Jonuary 29, 1 '//1 •
The cpproximato locctlom at which thu tt:'..ls woru tuLcn and the fin st results om presontc;cl
on pa()CS T-1 to T-43, lndusivo, u11dc1 1111,; 'ToLlo of ·rest ~:csul ,~," :1roup of 9 test!> taken
during the lnith,I groc.Jinu of /\lvu f;uu J u11.,; i11c.luJoJ 011 pnao T-43 ol •1•o "Table of fest Results."
The loboroto,y dJtorminatlons of tho rno,dniurn Jr,' d(:nslties and optimv111 moisture content, of
-··
·, '
f · • '·' ·; . l Li' ,,. ' ) . 'rOj~C: 1'-lv . l --•-/J, -:~-Ocr,1!>; r 1~, 1~'/1
· ·Roncl,o Lu ~c:.t-1
~
the: mcjor fill.r.iot~iicls c ·c prcscnt ct1 0 11 1,,, 1,•r, 1.-1 <•)d 1.-2, undor 1110 ''LolJ01 ,1t(l,y Tes~ R~-;0lts.11
Svme or th0 rt1axim11m dry J ~nsitics !.lv:,w:1 in 1k , ·'Td,lu of Test Results" wcro c0r.1binal'iom of
th~. The tests were tal:cn <lurino the ,·.-, .. -.-!dr 1,crh:d~ in<licatc<l bJlow:
Te:st Number
1 to 12, indusivo
13 to 4G, inclu:.ivo
4? to 79, indusive
SO lo 10-i, indu:.ivc
107 to ~r.9 inclu~lvo
159 to 200 inclu:;ivc
201 to , i11clusivo
24J to 319, inclu~ivc
320 to 360, inclusiv\l
361 to 441, inclusive
442 to 552, inclu~ive
553 to 629, inclusive
630 to 705, inclusivo
706 to 77,t, inclu!oivc
775 to 870, inch1sive
871 to 947, inclusive
948 to 1039, indusivo
1040 to 1121, inclu:;ivo
1122 to 116i', inclusivo
1168 to 1?.lu, inclusivo
1217 to 1232 , inclusivo
1233 to 12i'4, inclusive
1275 to 1283, lnclusivo
1284
1285 to 1291, inclusive
1292 to 1293, inclusive
1294 to 1303, lnclu!.lvo
1304 to 1307, Inclusive
1308 to 1320, lnclu~ive
1:121 to 1329, inclusive
1330 to 1335, inclu!.ive
1336 to 1350, lnclusivo
1351 to 1356, inclusive
1357 ond 13!,U
1359 to 1370, Inclusive
1371 to 1376, Inclusive
Wod; Enc.ling
Novcmb,.n 1 '1, 1 S' /0
Nov<..mwr21, 1970
Novombcr ~C, 1')70
Dcccrnbcr 5, l Yi'O
Dcc.\)mb~r 12, 1970
DcccmLor 19, 1970
January 2, 1971
January 9, 1971
January 16, 1971
January 23, 1 ?71
January 30, 1971
February 6, 1971
February 13, 1971
February 20, 1971
Fol.,ruory 27, 1971
Morch 6, 1971
tv\orcl, 13, 1971
Morch 20, 1971
Morch 27, 1971
April 3, 1971
April 10, 1971
Apri I 17, 1971
April 24, 1971
1-kJy 15, 1971
f,..~y 22, 1971
Moy 29, 1971
June 12, 19/1
Juno 19, 1971
Ju I y 17, 1971
August 7, 1971
August 14, ·1971
August 21, 1971
August 20, 1971
Soptornbcr 11, 1971
Scptom6or 18, 1 ?71
Soptombor 25, 1971
Lots 190 and 191 we1c not 01adcJ ond thc1cforo romain ot their original natural ilope.
l\r t-. HJN I t4,,lt41 I UU4:,. ltH ..
u ..:k ! ,. I /, 11)7 1 ...
1hc fi:1 ... l 1.;~ull!, c.•f I, ~I·, (.1:.1 ,!.-: ·,,., ·. 11: 1 ·,.::, -.: ll11.1 t ti:'.' r.1.;.,poct, d ,ill , :l u1 ;.;un l ;;.,., l ~,:,n
pieced ct 90. j-:.:Ct.:C.:lt c,f ir:;• 111-~"il.l"l'.l (!1~· ,· . j :r er ~;rco:.:r. It ho~ I:::·. II u..::crmin .:d ll1 at tl1c
fill r..c:le:1i~ls, co:-:i;;aclcJ I,) 1,:J r, .... ;cr.n1 ol 1:., ,, .·:1.i111um 01)1 dm~lty, h.i'.•..:. 0 sufo b~arino yq l,_.~
of 1?30 pvJ:-id~ p~r s-:;uorc: f.:ol f:,1 (>:) • fc::,t \Ii,' ,·,J1ii inL'u1°·. f.._•otinr,!:. f1YJ,1.l..J at a minim~rn depth
of en::-foot L,clow finU, r:rc,!.: c:,1,11·•lc.1..:.,: :1 -: .. {, t 01 1,,u,11 inddc thl? ti,·> of corn:,cc t,:cl fillnd ~ I •
ground d:,,,1.:5, If foo:i,, ;:, <110 r,kc~J ck:_, ,., ,:. : u:,::i:c.:J sl1-;'.'S them 5 fc..:t imh!,.! th.: tc p of
corr.?octd !illcd !J10L1riJ ~i o1~,•;,, lh~ · .i d1, . .11ol,! I· d: .:.i:,cncd c,n\! foot lic.:IM, a 1 1/.?. l,o.-izontcl to
1 vcrtic'--1 lir,c p1:iil.dl.'..11 "ulw~rJ c111d ,b v11 ,,:.;r., 1,0;~1 o p,dnl !j feet huri:.0:11.::illy in:;:c.fo t'10 top
of compactd fill!.!~ u::1i.:11u ~le-:-,~~-·1c-~1 .. i11,:,,_,,1, tk,t t!io CC..1111~0..:te,cl filkJ u1utrnJ i:; nr.lr-:q uate
to soti!fc~lorily Sl;pport tl,o J.,ro;,o~-.J wo"'I 11,.1:. dw~d linu~ \Vilhout <lotrin1::ntcil sottl<.:rn.:nts.
Expensive day, ~ilty d u}', 011J ~C:'.i:;)' c.lui' ~l,il-.. ...... ,..: plul:•~d in tho lJ,-•j •.1 thrco feet in :crl·oiri
com;;cct-:J fill Oh.;~~ .:mJ c.ho c;.i:t in•~ .... u,>i•-1 11..;.o fcut L luw finislH .d t.;1c..do in cotutn cut
creel$. ilit. final cla;))iiication .. of 111..: sci I condition:. oxi~tino on each lot uro presented as
follov.1:
Lots
lo 16, lnclu~ivu
I~ to ~1, tnc.lu)ivu
34 to 50, inclu~I vo
52 and 53
50 to 6-1, inclusiv1J
66, 67, c.inJ 63
70 lo 02, i11.;.lu:.ivu
87 tll 92, i11c.lu .. lv1J
105, 1 o.s, 107
117 to 131, ln.:lu:.lvu
I l'J
Lots
17, ~1, 54, 55, 56, 57
65, 6-J, 03, .!H, cs, 06
93, 22, .l,0.1, l0J, 109, 110
112 to 11.'.>, inclusivu
lots
3J
94 to 9U, l, ... luilvu
100 h> 1 O~;-i11e.lu~ivu
111, 116
Lots
13,1 lo 1 '19, tncl usiv0
152, 1!>3, 154
158 I.> 161, tnclu~iv\J
167 to 1i'6, inclusivo
179 le, 102, inclu~ivu
10j " o 189, lnd1,;ivt.!
19'1 to 2:JO inclu:.iv'1
234, 2
239 lo 2'13, tncluslvu
246 oncJ 247
Lots
132, 133, 150, 151
155, 1!>6, 157, 162
1n 011cJ 170
183,192,193,238, 244und248
Lots
163 to 166, tnclusivo
231, 232, 233, 235, 236, 245
249 to 253, tnclustvo
11t t JH•I .. I t1 .1,,.1 I 11UH, la.''-·
hcic<--1 l~v·. i'1>-10-::,,u .. ., ·-· l ·-
£:<$1,d-,c ~c C.·:a
It is 1ccQr.,:-;:1·:.'d~-J that t:·,~ fo :lo,·1i11~i :,:. ,:it I d"~:~:.1 r:,,d p:c.:coutions he token for t!w houses to
bo construc ted 0:1 the c,~~v ::• lo~s :
-t( AvotJ th~ l i'.'.~ of i~:-i!t.t ., 111 ,:ra,r pi,:r!>. ll:.c continu,-:,us footings throughout,
einJ pl c,-..1: ri, .:.a at u 1"i1.i, .. ,,111 dq,tl1 ,,i' two feet l>c:low tho lowest ocljaccnt
cxl.::rior fi1 1~.1 urou11d !ti,it ... (;.
r,1.;ir,fo ic.:. L.,hl i11torconr,~ .. 1 , v111,111 o u.ly ,-1itli steel l>cr1s oil interior and
ex•l·ii·Jr f,_,~J:ir:;":$ will,,::·.''> l1.,1 l•t :; i1.c!:.:::. oLovc,; Ilic l>ottom of the footings
onJ om: ··5 L..:1r plct(,. ! 1 1/J i11t.k.-. 1:-Juw tliu top of the sh.:ms of the footirius.
Ex\!rcb..: l..\','ry e ffo rt 10 c · .urc tl1'JI 111.:i s:,il 11nJcr th:.1 foundutions o nd slCJ!,s has
o uniforr,1 m~•b luro C:<•ni iii, 1 p~:rc.;l nt· lu 3 porcf!nt nrl.Clh!r Ilion ujJtir,1u1n through-
out tho lei:, :J 1·~e:t b:.::ow f rnU,oJ or.:.d.J at ti10 tlmo of JJluci119 foundations and
slabs.
Uso 1c:is.:!d \'J.J.ld..,11 ll o," ... ,:.~,t :.pc1n k.h·:1.,cn contlnuou:. footings, or uso oil
conc1ot-.! :.bl·J with 6 ·< <:, •• l(flO Wl.ld. J wiru fabric ond µroviJ3 a minimum
of 4 inchc,.; <Jf ,. l~cin ~ud l).m.;:l·th oll cc111.:r<..tc slal>s . /\ moisture l>arricr
should b.:, riroviucd in iii:. ~ur.:.l l:1;1.:r 2 inclws below slobs under living areas.
s~pa,at.J cm<:,·,J i.lcJ:.-·; fr,·,11: p.:rir:,.;tcr f iotinas by a 1/2 inch thickness of con-\
structio11 f'-·11 01 equiv,,!, iii, t...., ,.i l,,-,., :mkpc:11dcn t niovcrncnt of QC1C1gc slobs
rolutiv~ l u i:-.ri111.~li :1 tv.,1i1,:.;~. /.!.:,u1 ... lu1111~l:..tc i.cpwcrtiun Ly oxtcncling the?
felt ov.:r tl.l: 1'ull cLw.L_,,i :liw f1 u11t tl1 it.l,,•11~J cuuc.: or th.J gu1uoe slab. Al~o,
cut off tli~ o ,Jlll:.Ju door :.il,•$ ut· kast 1/2 i11ch ubove tire slul>.
Provide po~ilh -.! clroinl::1,: 1",:'1}' f1cm C1ll pcrimc:tcr footings to a horizontal
dlstancu of c..t least 6 i1.~t uul:.i~.! tho h.:,uso walls.
Those lol'i listed as Type 13 lvl:> :.houlJ fo!l o\'I all tho <Jl>ovc-li~tcd rcco111111cndation, ·vilh the two
following exceptions:
1. Thu continu..111=. foo ti1,:is lllll/ liJ pla.:::cJ at a minimum depth of 10 i11cl1c:. below
tho lowci.t oJjuccnt u>-.101 il,r fi11ul u1ou11J su,foco rotlicr tl,an tl1e two fcot
recomm::mJl.!u for Type A l0ts.
2. Sln:)lo 54 lio1:i pluccJ o:. dlit ctod (oLovu) noar tops ond L10ttmns of oil interior
and cxh.•dor footing:; may Lo ~u6;tituh,J for the 115 bars rocomrncndod for
Typo A lots.
P.ecommcndotium 3 I-> 6, inc ll1:,ive, os li~llHI for Typo A lots, ore also oppllcol>lo to tho Type
B lots.
•
P,o;<. .. t I,.:,; /0--ii..: .. ~.:,:.,
~c:·,:1-,J_ Le Cc:.l.:.i
On!;· 1,c:1cxp.:m~ivc• ~.:.,;! condilit,r,,; ·:1v 1c <../, .• ,,.. d ir, I:,_· u1 •;,cr thr.:io feet <.'11th~ Type C lo:-i.
ond therefore.: ~p .:ci~lly dc~io n·-J 1·iJ(.,lillfJ, t,11d '.-k '.J· will not li.J required on 11,cso lots.
Rcs;.;~clfully submitt~d,
BENTOl-.l ENGl!·~EE!'ING, INC.
B "7 ,.,.~ _,·;,, y ·-',{-. ·.t·'_•.· .. •-~-·:· ----·-
R. C. R~;:,cr
, . -) } . . ) --. -. J ,, ,, I ) , • .: ••• -·-
Revi~~/\..J b~ , 1:. !, ".,, "\, / ( _· • , ·,; .:~;: ., ''-ce.----;_,._--.ll-~----..
O(str:
Philip IL Denton, Clvil E11uincur
(7) AlJH.mcc
(2) Rancho La Costa, Inc.
Attention: Mr. Uu,ton L. l~fl :r11ur
( 1) Rick EnginccrinJ Co;npcmy
(2) S.JJ\ D;l .JO County Cuil~in~J lw,:.··,c lion
Vista Off1ce
LEUCADIA COUNTY WATER DISTRICT
APPI.ICATION FOR SEWER SERVICE
Owner's Name Ted Goldberg
Mailing Address 2311 Via Aprilia
Phone No. 481-6944
----~-----------Del Mar, CA 92014 -SJ,,
Service Address : .;25£/! Lucierna9a Street ~ J'S 5
Tract Description: lot 200, La Costa Meadows JI,,/
Assessor's Parcel No. 215-300-07 --------------Type of Building ___ du~p_l_e_x ___ No. Units 2 Connection Fee
Lateral Size: 4" 611 811 Saddle Easement Connection(pre-pd
Extra Footage: __ @$ Extra Depth: ___ @$ __ _
Amount Rec'd $_800.00
Ck. No/Cash #030854
Lateral Fee
Prorated Sewer
Service Fee
$1 ,200. 00
400.00)
800.00
Date 9/12/79
Rec'd By SLW Total $1 , 200. 00 ----
The application must be signed by the owner (or his authorized representative) of
the property to be served. The total charges must be paid to the District at the
time the application is submitted.
If a service lateral is required, it will be installed by the Leucadia County Water
District. The service lateral is that part of the sewer system that extends from
the main collection line in the street (or easement) to the point in the street (at
or near the applicant's property line) where the service lateral is connected to
the applicant's building sewer. The applicant is responsible for the construction,
at the applicant's expense, of the sewer pipeline (building sewer) from the appli-
cant's plumbing to the point in the street (or easement) where a connection is made
to the service lateral.
The connection of the applicant's building sewer to the service lateral shall be
made by the applicant at his expense. The connection must be made in conformity
with the District's specifications, rules and regulations; and IT MUST BE INSPECTED
AND APPROVED BY THE DISTRICT BEFORE THE SEWER SYSTEM MAY BE USED BY THE APPLICANT.
THE APPLICANT, OR HIS AUTHORIZED REPRESENTATIVE, MUST .NOTIFY THE DISTRICT AT THE
TIME INSPECTION IS DESIRED. ANY CONNECTION MADE TO THE SERVICE LATERAL OR COLLEC-
TION LINE WITHOUT PRIOR APPROVAL AND INSPECTION BY THE DISTRICT WILL BE CONSIDERED
INVALID AND WILL NOT BE ACKNOWLEDGED.
The prorated sewer service fee is based upon the date the District estimates that
service will begin and covers the balance of the fiscal year. There will be no
additional fee or refund if service actually corrmences on a different date. For
succeeding fiscal years, the sewer service fee will be collected on the tax roll
in the same manner as property taxes.
The undersigned hereby agrees that the above information given is correct and agree~
to the conditions as stated.
9/12/79
Date
-c"' -· • -----··----
✓ Ool I 'l..-l 0337 T"Ac_c_o_u_n t-,---:-N~o-.
•