Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2555 EL CAMINO REAL; ; CB051722; Permit
City of Carlsbad 1636 Faraday'Ay Carlsbad, CA 92008 01-05-2006 Commercial/Industrial Permit Permit No: CB051722 Building Inspection .Request Line (760) 602-2725 Job Address: 2555 EL CAMINO REAL CBAD Permit Type: TI Sub Type: COMM Parcel No: 1563021000 Lot M 0 Status: Valuation: $30,814.00 Construction Type: NEW Applied: Occupancy Group: Reference #: Entered By: Project Title: JCPENNEY PORTRAIT STUDIO Plan Approved: 944 S_ F TI PORTRAIT STUDIO TO THE SAME Issued: Inspect Area: Plan Check#: Applicant: Owner: NUDELL ARCHITECTS NEW MARJORAM ASSOCIATES 0/0 JCPENNY CO ING#566-0 P O BOX 10001 950 SOUTH COAST DR 92626 DALLAS TX .75301 714-979-8100 ISSUED 05/16/2005 SB 01 /05/2006 01 /05/2006 Building Permit $248.55 Meter Size Add'I Building Permit Fee $0.00 Add'I Recl. Water Con. Fee $0.00 Plan Check $161.56 Meter Fee. $0.00 Add'I Plan Check Fee $0.00 .' SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $6;47 PFF (3105540) $0.00 Park Fee $0.00 PFF (4305540)- $0.00 LFM Fee $0.00 License Tax (3104193) $0.00 Bridge Fee $0.00 License Tax (43041-93) $0.00 BTD #2 Fee $0.00 Traffic Impact Fee (3105541) $0.00 BTD #3 Fee $.0,.00 Traffic Impact Fee (43055.41) $0.00 Renewal Fee $0.00 PLUMBING TOTAL. - $0.00 Add'I Renewal Fee '$0.00 ELECTRICAUTOTAL $35.00 Other Building Fee $.0.00- MECHANICAL TOTAL $24.00 Pot. Water Con. Fee $0.00 - Master Drainage Fee . $0.00 Meter Size I Sewer Fee- $0.00 Add'I Pot. Water Con. Fee $0.00 Redev Parking Fee $0.00 Recl. Water Con. Fee $0.00 Additional Fees $0.00 TOTAL PERMIT FEES $475.58 Total Fees: $475.58 Total Payments To Date: $475.58 Balance Due: $0.00 i FINAL PPRPVAL �rZ__ rInspector: Date: �� Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing -or service fees in connection with this -project, NOR DOES IT APPLY to any May,16. 2005 9:37W NUDELL ARCHITECTS No -MO P. 2 S PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 Uft Addrm (include Ew*ufte q) Business None (at addr—) FOR OFFICE USE ONLY PLAN CHECK N0,6�4'-,-/7 ZZ EST. VAL. S Q -18 Plan Ok. Deposit /42,A! VaildxW By, Date % Tv"t'No, sub"on Namm"ta Unit No. 83ft,*wc*/16/05 '1304560-iEft-772 AwesWs Parcel 0 Evifift Use - - -162-00 lot7r.A 1,44 Dwor"an of Work SO. Fr. #ofStorm tof Bedrooms lit of Waom$ V;jANWACT PEW$ Herres Address City Ste wzip Tawmm# Fax 0 :,111 CAM 13 conlirv**1.10 ,I, 4vFjF]R.,PK .:.! 110., NvowwRK Aqw*fbrOwrw 9 r A Norm Add' MA 5-aXZA AWA eA ,462 A IN& City -%tw7jp Talaphwe# -.bPfWYOWWR 9-CA2 �-�MWIWC, &W Lgv-40� Pr, FZAA0 Awl< V973Z�4 9V2,01, lr8n iNwrwAddrais City' st"Zo TabPbonat Sm 70311-5 &AIM and Pro( Coft, ,Wjcxyo� ww" e Cou* 4" requires a parm! to consbuct ahw. improve, demolish or repair any shtwhm prior to its JsNjanos, *0 MWW ft applicant for such PWO 10 00 a ftW VAWMM MIA! he W k4Wd pumaM to V)c prwjjgkM of the Cwkscbes License Low Ichap(er 9. wmmwwmg with SKfiffl 7000 of DhdWw 3 of the ftilnM and Pr0fjq*N,CoftJ of VW he 19 ~ rad"n, and ft b" for to alleged exampillon. Any Oulallon of SeWon 7031.5by liny applicant for a PAN vuwKk 20 appilcmd Jo a dyll Pendvof not more than diva hundred dollars (SSM). Tic 7603 Erlmf� ll 2 elz UOUM I'V4 4 Buturre" N"•'94 1 .:. '. �. - 11. t-3� �4m 1 " 1. , T T.-PROGWA , VS. .,*. , � . . 1. : Wcrk—'Commmwhcn6;�� 16;�yM6mderpww*yofpMWomoftela"Cie;loi� ! , . 0 1 hwe wA vAl m*galn a om of 0orwrit to $*am" me ftfMW CMPW*W- as pmvided by Secillon 3700 of OW Udw Code, lbr ft pacbmience of 1he VXA for which this peirrikk issued. bw* 00 YA mlk"n WwW9 cOmPOW1510111M. 48 fgq*W by 86dion 3700 of to Mw Co* for the pw*w=rm of to work for whlch We pbm* Is baw, W 'worker's 9mmPensawn'gdMftnaberam M lnNMwM4;11pany. Date% —0AP (TM'S ZkC"A Nftb Not ft C=Plfn= If T#= PSMIT It FOR ONE MMOMM DOLLARS 111111114 OR LESM 13 CERTMME OF 00111111ON! I a%* ow in ft paWMM Of- the ftrk ftf W" INS PC" 16 WSUOdi I " r0l employ any person in any manner so as to becomasubWid the Workers' Campensalon Lrwe ofCaftmon. WARNWO! fee" to seavre wadwww damp"Nowm Gossips Is Wo"A sad shsl sabl 0 an 0 VlOyff 40 ahkM VNININ" MW 6101 ffan up to am hundred dmsane "fars($190.0"N inp►nrMleefAgIly'aftep. SIGNATU DATG— •4, I,hw . eby dram Mot Iran OOW horn ft Cw*acWs Lionnes Lawforthe Mowing; . ranon: M 0 k a owner of " M" Or MY VM10YON with W" at #1& sole COMpOnCAM, WE d the work and dw du*ure Is not inbanded or offered for sale (Sam 7044, &A*1005 NXI Profteslons Code: The Corr o*es Lianas Low don not a* to an oww of wqxuty Wm bulds or hvmm itwom, and OV OM %joh wok NM"Vor UNW hie Ow ampidym, pmmeq ilia SuCh kypbvanmft am not kdodad or offered for sale. If, however; im building or Improvement ia acid within one yaw of complalon, the ownar-MdarvA twiethe Widen ofpvft" I* ddr,*t b* or kpove (offt purpose of$*). 13 I-imowner 4DFftproperty, amoxokmti*ooiA rig with licensed conbeclors to coneftW the projed (See. 7044, Businase and Professions Code! TheftlbacMr's Ucense Law does not M* 10 an 0wrw of property who-bulds of limprom Hanson, and eonbade for such Frojeels VA Mkocior(s) licensed pursuant to fie Conkscloes Ucenn Law). [3 lam axon wft Secka Business and Prollownions Code for this mason: 1, I peftdrrNlyphm to prca4de dwI manor fabor and malalefa u YEr, 0 NO 2 1 (haveftaw not) 90W an mppligirim for a building pan* forl1he propoeed Wwk, 3. 1 have omftded Wth the f0*AV person (iht") 10 provide the pq=W wnebuction (Mducle new taddmas I phone rRffnbwl contadom kwmw number): 4. 1 plan to Provide pordons of the work, but I how hired the Wow[nq person to cowdnm* eupavi"manor{Include name taddrm / Woe number I knmwra kalm number), 5- 1 VAII PMVWS am* of the *0d4 but I have conkaded (hired) the V+e vmt Indwed /type of wale): PROPERTY OW14ER SIGNATURE DATE — M is, WWITV- 9:0& V.91 I nW- Ari.i .f PjJJV. rj.an..a May -16. 20056 9:88AM;05 MUDELL ARCHITECTSID FAX NO. 760 602 g - 2230 P. 3 p, 03 PERMIT APPLICATION CITY OF CARLS13AD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 Page 2 of 2 rN 1 �i�aeircx�zarraar r�..o..., -tea. t.w -.._ _ uflQw jr, urtr tef t*nt or future buittltlQ OeOapard roaWrea ro auttrA a buOMP 014ft, huwdm a ra *.Iiw rotor tk tMnaaun,ent end pawn Ott WO9►a^t SecxiorA Zo6os, zaeao or 25t104 0l the lraaler'l r+n & Ntasrdmw SUWtan&e A�Mt AW G YES ❑ NO Is Ina appmeetw w future building *—Pont POW to oblrn a pamrit ham>tte pit P��n caved diMrld or alr 9uaYry managameM didritt? O VEti R NO 1s the facmy to ha wwft cted wHNn 1.00016M of the cline bo 04my of a ad10Pl rte? fp YIW U NO IF ANY OF M ANSWIRS AKIL YGIN A FINK CE�R71FICKM DF 0=pAW" MAY NOT Mg *SUED UNLESS TMI APPLICANT NAS MI" OR IS MlrETING'fHE FIWL RW1WTS OR THE OFFICE, (W &MSFIGINCY SIRWCEII AM 7W AIR POLLUTION CONTROL DIBTMT. .y • 1 hera+y apfirm u>wt Ihate ISO cm1ruacon iamm appattcy P a" na d th• •ro►9 Rom Ich urn parrhN is iwww(See. atOW OW Coda). t.ENDER'S NAME � . LiNOWA S AW"SS il1t i the W'Ptl�tlpt and 0tet"the abawr IltfonnallOn Is owed and ehM WIa infOlrnadan On tla pair it ecuum". 1 e0►�M to pomoy wim ah City ormnopow and Slde law& r'WWmV to N j1k AQ oo "MjdW' I hMaby �Krtl ap rapraaatda0vea of lhs Cify of Cadsbwd to Mtat upon thn above rrteAllated pMtr,ny forir>•pstalon purpoaaa. 1 ALSO AGRIF TO SAWs. I"WRIIFY AND KUP }WARMLPHS THS CITY OF CARL8IIIID AOAINiT ALL uAatunrs, JUDfi#IMF1tTs. 417sT! AND p(pgNsi8 WINCH MA7IN ANY WAY ACCIWN AaAWST SAID CITY IN CONOICURNCE OF O R-GRANTING OF TiNs PERMIT OBNA: An t3611A parmh is MgWrad for 0004lorlt vl so* dgpp and datrl OM or ot7Mwcmn of gtpyaures ovar 3 sknios In halyht. + EXPIRATION: RWaty popmit ieauad by 14hep OMICJaI thv proviaiOns of this Coda and m,$m by lIW34dw and bomme nd and Miff" U111c np OrwolFt auuwtked by such pWMV is not commenced whMn days Own the data w 11wh petrel of U the bwdrg or work authorizod by AUM "nitil le cusps d or abrndanad M AN Nma j,tlnr 414 "k lscomntartCOd for ■ pa11 Oil yg ( on 109.4.E llrelOnh i puildnp COOe). APPLICANT'S $ICINATURE I r DATE WHITE: File YELLOW: Appliont PINK; i1nsincs Inspection List Permit#: C9051722 Type: TI COMM JCPENNEY PORTRAIT STUDIO 944 SF TI PORTRAIT STUDIO TO THE SA Date---. _ Inspection Item Inspector _ Act 08/07/2006 89 Final Combo PD FI 02/23/2006 89 Final Combo PD 02/07/2006 14 Frame/Steel/Bolting_ /Weldin PD 02/07/2006 34 Rough Electric PD CO PA PA Comments CONTRACTOR FAXED -OVER FINAL INSPECTION RECORD CARD SIGNED BY PD NOTICE Monday, August 07, 2006 Page 1 of 1 City of Carlsbad t x.. _ ^ � 1635 Faraday Avenue, Carlsbad California 92008 INSPECTION RECORD " t V v4� INSPECTION RECORD CARD WITH APPROVED PLANS --^ MUST BE KEPT ON THE JOB �� � CALL PRIOR TO 4:00 P.M. FOR NEXT WDRXDAXjNSPECTION �y BUILDING INSPECTION• (� JOB ADDRESS: a.- CB051722 2555 EL CAMINO REAL CBAD OWNERS NAME: JCPENNEY PORTRAIT STUDIO USE/OCCUPANCY 944 SF TI PORTRAIT STUDIO TO THE SAME TI COMM Lot#: NUDELL ARCHITECTS BUILDING -- OTHER LOT NO./SUITE: TYPE CONST DATE ��— CONTRACTOR APPROVED TO COVER_ Date Inspector BACK FOR SPECIAL NU I t: ON of Carlsbad a Final Building 1080CHOR Dept: Building Engineering Planning CMWD St Lite if r!t Plan Check #: Date: 02/22/2006 Permit #: CB051722 Permit Type: TI Project Name: JCPENNEY PORTRAIT STUDIO Sub Type: COMM 944 SF TI'PORTRAIT STUDIO TO THE SAME Address: 2555 EL CAMINO REAL Lot: 0 Contact Person: MIKE Phone: Sewer Dist: CA Water Dist: CA ................:......................................................... ... ....................... :......... ............................ :.....;/w Inspected Date �� Approved: disapproved: gy; Inspected: Inspected Date By: Inspected: Approved: Disapproved: Inspected Date By: .................................................................................................................................................:........, Inspected: Approved: Disapproved: Comments: EsGil Corporation In TPartnership with Government for Building Safety DATE:, 9/21/05 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 05-1722 SET: III ❑ APPLICANT RIS. ❑ PLAN REVIEWER ❑ FILE PROJECT ADDRESS: 2555 El Camino Real (JC Penney Store #0566) PROJECT NAME: JC Penney Portrait Studio Renovation ® The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. ❑ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. ❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ❑ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. ❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact, person. ❑ The applicant's copy of the check list has been sent to: ® Esgil Corporation staff did not advise the applicant that the plan check has been completed. ❑ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person ❑ 'REMARKS: By: Doug Moody Enclosures: Esgil Corporation ❑ GA ❑" MB ❑ EJ ❑ PC 9/14/05 tmsmB.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, Califomia 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 EsGil Corporation in Partnership with Government for (Building Safety DATE: 9/2/05 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 05-1722 SET: -II ❑ APPLICANT ❑ JURIS. ❑ PLAN REVIEWER ❑ FILE PROJECT ADDRESS: 2555 El Camino Real (JC Penney Store #0566) PROJECT NAME: JC Penney Portrait Studio Renovation ❑ The plans transmitted herewith have been corrected where, necessary and substantially comply with the jurisdiction's building codes. ❑ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ® The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. ❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ® The applicant's copy of the check list has been sent to: Nadell Architects, 950 South Coast Drive, Costa Mesa, CA. 92626 ❑ Esgil Corporation staff did not advise the applicant that the plan check has been completed. ® Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Nodell.Architects Date contacted: 9 t z 105' by: ��c) Mail --Telephone Faxes In Person REMARKS: By: Doug Moody for Edward Wilczak Esgil Corporation ❑ GA ❑- MB ❑ EJ ❑ PC 8/25/05 Telephone #: 714-979-8100 Fax #: 714-979-9626 Enclosures: trnsmtl.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Y' City of Carlsbad 05-1722 - 9/2/05 RECHECK PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PLAN CHECK NO.: 05-1722 PROJECT ADDRESS: 2555 El Camino Real (JC Penney Store 40566) SET: II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED: ESGIL CORPORATION: 8125/05 9/2/05 11 REVIEWED BY: Doug Moody for Edward Wilczak 11 FOREWORD (PLEASE. READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department., You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed, need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state,, county or city law. A. Please- make all corrections on the original tracings .and submit three new complete sets of prints to: B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list._ If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? ❑Yes ONo y' City of Carlsbad 05-1722 9/2/05 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to. EsGil Corporation, 9320 Chesapeake Drive, Suite 20,8, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their- Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning_, Engineering and Fire Departments until review by EsGil Corporation is complete. When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the requirements for new buildings; per Section 1134B.2. These requirements apply as follows: a) The area of specific alteration, repair or addition must comply as "new" construction. b) A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with accessibility features. c,) Existing sanitary facilities that serve the remodeled area must be shown to comply with all accessibility features. Show that grab bars comply with the following, per Section 111513.8: a) They shall be securely attached 33" above the floor, and parallel. NOTE: Where a tank -type toilet is, used.which obstructs placement of the rear grab bar at 33", the rear grab bar only may be installed as high as 36". Please revise the women's. restroom plans to show the clear area in front of the water closet for a side entrance stall to be 60" minimum. Please clarify the scope of work 1 was unable to location the wall construction details for the new walls? Are these under a separate permit and not part of this permit? Is the lighting and alterations to the electrical system under a separate? There was no energy documentation for the new lighting? Does the ceiling exist? I was unable to locate the details for the construction of a suspended ceiling? Please provide the following note per the City of Carlsbad; "AC Cable is not allowed in A, B, E, H, and I occupancies. NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible conduits". • EsGi-I Corporation In (Partnership with Government for Buifding Safety DATE: May. 27, 2005 ❑ AP LICANT ❑ 4URI . JURISDICTION: City of Carlsbad ❑ PLAN REVIEWER ❑ FILE PLAN CHECK NO.: 054722 SET: I PROJECT ADDRESS: 2555 El Camino Real (JC Penney Store #0566) PROJECT NAME:. JC Penney Portrait Studio Renovation ❑ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. ❑ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked -by building department staff. ❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ® The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. ❑ , The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ® The applicant's copy of the check list has been sent to: Nadell Architects, 950 South Coast Drive, Costa, Mesa, CA. 92626 ❑ Esgil Corporation staff dial not advise the applicant that the plan check has been completed. ® Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Nadell Architects (CHI Telephone #: 714-979-8100 Date contacted:,5 'f 3 A5� by: r, --) -Fax #: 714-979-9626 Mail --"Telephone' cv Fax - In Person ❑ REMARKS: By: Edward Wilezak Esgil Corporation ❑GA ❑MB ❑EJ ❑PC May 19, 2005 Enclosures: trnsmtl.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 City of Carlsbad 05-1722 May 27, 2005 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 05-1722 OCCUPANCY: M TYPE OF CONSTRUCTION: ALLOWABLE FLOOR AREA: SPRINKLERS?: REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: May, 27, 2005 FOREWORD (PLEASE READ): JURISDICTION: City of Carlsbad USE: Portrait Studio ACTUAL AREA: ,STORIES.: HEIGHT: OCCUPANT LOAD: DATE PLANS RECEIVED BY ESGIL CORPORATION: May 19, 2005 PLAN REVIEWER: Edward Wilczak This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections base_ d on laws and ordinances enforced by the Planning. Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based. on the 1997 UBC. The following .items listed need clarification,, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet. number, specification section, etc. Be sure to enclose the marked up list when you submitthe revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiformclot City of Carlsbad 05-11722 May 27, 2005 1. Please make all corrections on the originals and' submit two new, complete sets of -prints, to: Esgi) Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, CA 92123, (858) 560-1468. When alterations, structural repairs -or modifications,or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the requirements for new buildings, per Section 113413.2. These requirements apply as follows: a) The area of specific alteration, repair or addition- must comply as "new" construction. b) Existing sanitary facilities that serve the remodeled area must be shown to comply with all accessibility features. Show location and provide floor plans of restroom facilities. These plans will be checked for compliance with disabled access. requirements after they are provided for review. c) Existing -drinking fountains (if any) must be shown to comply with all accessibility features. Show drinking fountain locations and details on plans. 2. Clearly,show that the site development and grading are designed to provide access to all entrances and exterior ground floor exits, as well as access to normal paths of travel, per Section 1127B.1. Where necessary to provide access, shall incorporate pedestrian ramps, curb ramps, stairways and handrails, etc. 3. The tops of tables and counters shall be 28" to 34" from the floor. Where a single counter contains more than one transaction station, such as a bank counter with multiple teller window or a retail sales counter with multiple cash register stations, at least 5% (but never less than one of each type of -station) shall be located at a section of counter that is at least 36" long and .no more than 28" to 34" high. Section 1122B.4. 4. Show the mounting height for the dressing room bench (shall be between 17" and 19" above finished floor). 5. - Show mounting height and dimensions for dressing room mirror. 6. Sheets A7, A8 and A9 are not complete as submitted. ,j. City of Carlsbad 05-1722 J May 27, 2005 VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: Edward Wilczak PLAN CHECK NO.: 05-1722 DATE: May 27, 2005 BUILDING ADDRESS:.2555 El Camino Real (JC Penney Store-#0566) BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING PORTION AREA (, Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Ten. lm rvmnt. 1002 _ 31..00 31,062 Air Conditioning ,Fire Sprinklers TOTAL VALUE 31,062 Jurisdiction Code ICB IByordinance 1994 UBC Building Permit Fee 1994 UBC Plan Check Fee V Type of Review: Complete Review ❑ Structural Only ❑ El Other Repetitive Fee � - —n Repeats ❑ Hourly Hour Esgil Plan Review Fee Comments: $254.11 $165.17 $142.30 Sheet of macvalue.doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER Co D � I ? DATE Sf 2 �{ � ASS ADDRESS: �' S 'E7 (' 6 t ►� © �2 RESIDENTIAL RESIDENTIAL ADDITION MINOR (< $1 O,000.OQ) 0 TENANT IMPROVEMENT CAMINO CARLSBAO COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER Alk DATE ENGINE DATE �b2�JUS Larisbad Fire Department 051722 1635 Faraday Ave. Fire Prevention u,-Caflsbad, CA 92008 (760) 602-4660 Plan Review Requirements Category: Building Plan J. Date of Report: 05/23/2005 Reviewed by: Name: Nudell Architects Address: 950 South Coast Dr. City, State: Costa Mesa CA 92626 Plan Checker: Job #:. 051722 Job Name: J C Penney Bldg #:. CB051722 Job Address: 2555 El Camino Real Ste. or Bldg. No. ❑ Approved The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and- standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. ❑ Approved The item you have submitted for review has been, approved subject to the Subject to attached conditions. The approval is based on plans, information and/or specifications provided- in your submittal. Please .review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. ® Incomplete The -item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Review 1st 2nd 3rd Other Agency ID FD Job # 051722 FD File # Requirements Category: Building Plan Requirement: Pending 05.01 Project Data Provide complete address and suite designation. Provide building construction information indicating occupancy classification, type of construction, number of stories, aggregate square footage, occupant load,, and description of intended uses. cREVISE:7B:UILDING DATA- INCLUDE FIRE- CODE REFERENCE: 2001 CALIFORNIA FIRE CODE. DELETE:AL'L'REFERENCES-TO'WITHIN L.A. CITY" Requirement: Pending 05.03 Floor Plan Provide a complete floor plan of building or suite. Show exiting from all areas. Indicate use or occupancy of each room including adjacent suite if applicable. . CP_ROUI©E C?ETAIL WITH.HEIGHT OF CHANGING ROOM WALLS. IF FULL HEIGHT (>72") THEN ADD FIRE SPRINKLER COVERAGE. Requirement., Pending 05.15 Automatic Fire Sprinkler System Required A fire sprinkler'system is required for this building." If the building is a spec building (no tenant known) the sprinkler system must be designed to .45/3000. Provide notes on the plans that fire sprinkler plans will be submitted to the fire department for approval prior to installation. CANYG-R— SS TO EXISTING FIRE SPRINKLER COVERAGE IN EXCESS OF SIX HEADS SHALL REQUIRE PLANS TO BE SUBMITTED. ANY CHANGES TO EXISTING SYSTEM SHALL REQUIRE AN INSPECTION. Page 1 ' 05/23/05 CB051722 2555 EL CAMINO REAL CBAD 1 ' JCPENNEY PORTRAIT STUDIO , 944 SF TI PORTRAIT STUDIO TO THE SAME TI COMM Lot#: NUDELL ARCHITECTS QN 05, Cam-, To 9 BulLom PLANNNG ��*Fft 6Rfi HMTH OEPT _ HAZMAT /AIR QUAL TO �..r OTHER SEWER DIS?R APPLICANT. P E S'M 1ME? BLDG FEES COtiAPLETE PLAN CORR �e CORR IL CORR CORR