HomeMy WebLinkAbout2555 STATE ST; ; CB151278; Permit10-19-2015
Job Address:
Pennit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
· City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Residential Permit Permit No: CB151278
Building Inspection Request Line (760) 602-2725
2555 STATE ST CBAD
RESDNTL
2030543431
$331,697.00
1
0
Sub Type:' CONDO
Lot#: 31
Constuction Type: 58
Reference #: CT130005
Structure Type: 1MF5+
Bathrooms: 0
Status: ISSUED
Applied: 04/28/2015
Entered By: JMA
Pian Approved: 10/15/2015
Issued: 10/15/2015
Inspect Area:
Project Title:.
Orig PC #: PC140037
STATE ST. TOWNHOMES: PHS 3 B4A
Plan Check#: PC150022
421 SF 1ST FLR COMMERCIAU1,943 SF LIV/ 458 SF GAR/ 88 SF
BALCONY/ 731 SF ROOF DECK
Applicant:
TAYLOR MORRISON OF CA, LLC
STE 1450
100 SPECTRUM DR
IRVINE CA 92618-4935
949-341-1289
Building Permit
Add'I Building Pennit Fee
Plan Check
Add'i Plan Check Fee ·
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
HMP Fee
Pot. Water Con. Fee
Meter Size
Add'i Pot. Water Con. Fee
Reel. Water Con. Fee
Green Bldg Stands (SB1473) Fee
Green Bldg Stands Pian Chk Fee
Total Fees: $30,067.43
Owner:
$1,445.02 Meter Size FS1
$0.00 Add1 Reel. Water Con. Fee $0.00
$1,011.51 Meter Fee $317.00
($500.00) SDCWA Fee $4,800.00
$0.00 CFO Payoff Fee $0.00
$43.12 PFF (3105540) $6,036.89
$6,190.00 PFF (4305540) $5,572.51
$0.00 License Tax (3104193) $0.00
$0.00 License Tax (4304193) $0.00
$0.00 Traffic Impact Fee (3105541) $0.00
$0.00 Traffic Impact Fee (4305541) $0.00
$0.00 Sidewalk Fee $0.00
$0.00 PLUMBING TOTAL $210.00
$0.00 ELECTRICAL TOTAL $89.00
$0.00 MECHANICAL TOTAL $65.38
$0.00 Housing impact Fee $0.00
$0.00 Housing inlleu Fee $0.00
$3,931.00 Housing Credit Fee $0.00
FS1 Master Drainage Fee $0.00
$0.00 · Sewer Fee $842.00
$0.00 Additional Fees $0.00
$14.00 Fire Sprinkler Fees $0.00
$0.00
TOTAL PERMIT FEES $30,067.43
$30,067.43 Balance Due: $0.00
Clearance: ------
r:i ~ f:)tject lrdu:les !ha irrµ:stlm' ri f88l3, d:daikns, reservalals, CX" cthar 6l(Bjjcrs rerea'ter w'led!V£fy
refmed to as "feee'exalla-s. • Yoo . 9J days frcrn !ha date ttis ~ v.es lssu,j to l)(test 111lX)Sitlal ri th3se fee:/exa:fu1s. If }Q.J µ'dast tlBn, ~ ll1.l3t
fdloNth3 µctast ~ sa fcrth In ~ Gem SectJa, 60020(a), ard flle th3 IJ'C,t9!! a"d ITT'/ cther ~red lrtarrEiim wth the Qty~ fer
~rg In acmda ce wth Carlsboo M.rldpal Gem SectJa, 3.32.cm Fl'Jtre to ttrrely fdloNtha: p-cxmtre wU tu-Fnf sutsecµrt legal Ed!CJl to atta::l<,
re-,!ew, set asloo, -.oo, a-ITTU trer lrflD31tkn
Yoo a-e t-erecy FlRTl-ER NJTIF18) !rat~ rig"i to µctast th3 ~ fee:/swa:tlcns CXES t\01" .APA.. Y to wm-a"d -.er oo, iectla, fees a"d ~
crargis, na-panrg, zairg, gad rg a-cther slnila" ~la=ilm pu:;esslrg a-ser-Aai fees In a:rndla1 v.lth tHs ~ed. f\m !XES rT />PA.. Y to at¥
Inspection List
I
Pennit#: CB151278 Type: RESDNTL CONDO
Date Inspection Item , ~~~~r ___ Act -~ --. -·
06/15/2016 89 Final Combo PY AP
06/15/2016 89 Final Combo RI
05/05/2016 39 Final Electrical PY PA
03/3012016 18 Exterior Lath/Drywall PY AP
03/25/2016 17 Interior Lath/Drywall PY PA
03/24/2016 17 Interior Lath/Drywall PY AP
03/24/2016 23 Gas/T esVRepalrs PY AP
03/17/2016 84 Rough Combo PY AP
03/16/2016 84 Rough Combo PY NS
03/08/2016 13 Shear Panels/HD's PY AP
03/07/2016 13 Shear Panels/HD's PY CA
02/24/2016 15 Roof/Re roof PY AP
02/16/2016 17 Interior Lath/Drywall PY PA
02/08/2016 15 RooUReroof PY AP
12/30/2015 17 Interior Lath/Drywall PY PA
11/16/2015 21 Underground/Under Floor PB AP
Tuesday, June 21, 2016
STATE ST. TOWNHOMES: PHS 3 84A,
421 SF 1ST FLR COMMERCIAL/1,943 SF L
Comments
COF AM PLEASE
Page 1 of 1
«~ ~ C1TT o,
CB151278 2555 STATE ST
CARLSBAD
,.. o{fdlng Divbion INSPECTION RECORD STATE ST. TOWNHOMES: PHS 3 84A
421 SF 1STFLR COMMERCIAL/1,943SF LIV/458SF
GARI 88 SF.BALCONY/ 731 SF ROOF DECK
'-cc:r'INSPECTION RECORD CARD WITH APPROVED RESDNTL . CONDO
PlANS MUST BE KEPT ON THE JOB Let#; 31 TAYLOR MORRISON OF CA, LLC
@ CAU BEFORE 3:30 pm,FOR NEXT WORK DAY INSPECTION
0 FOR BUILDING INSPECTION CALL: 760-602-2725
OR GO TO: www.Carfsbadca,qoy/BuHdtng AND CUCK ON
-Request lnspectionw .
RECORD-COPY
DATE: o-I -1 --.~1!1!11111-
Required Prior to Requesting Bulldlng Anal If Che<ked ~S
Plannlng/l.andscape 760-944-8463 · Allow 48 hours
CM&I (~ lmpcctloruJ 760-438-3891 ca11 before 2 pm
Fire Prevention 7 6()..6() Z-4660 Allow 48 hours
Type of lns~on Type of Inspection
co1>£ n ELECTRICAL . ·: · Date Inspector
#31 D ELECTRIC UNDERGROUND D UF£R
#12 REINFORCED STEEL #34 ROUGH ELECTRIC
'66 MASONRY PRE GROUT '" 0 ELECTRIC SERVICE O TEMPORARY
----OGROUT D WAl.l DRAINS #35 PHOTO VOLTAIC
#1D TILT PANELS
Ill POUR STRIPS ·.CODI:!),' MECHANICAL.·::-"· .. ',(·' :=
#11 COWMN FOOTINGS 141 UNDERGROUND DUCTS & PIPING
#14 SUBFRAME O FLOOR D CEILING 0 DUCT & PLENUM O REF. PIPING
115 ROOF SHEATHING HEAT-AIR COND. SYSTEMS
#13 EXT. SHEAR PANll.S
#16 INSULATION cocc:: COMElO INSPECTION ·. ·'
#18 EXTERIOR LATH #81 UNDERGROUND (11,12,21,31)
#17 INTERIOR lATH & DIIYWAU 1182 DRYWALL,EXTLATH, QASTES (17 18,%31
#51 POOL EXCA/STEEL/BOND/FENCE #83 ROOF SHEATINO, ID SHEAR (13,15)
#55 PREPLASTER/FIRAI. #84 FRAME ROUGH COMBO (14,24,34,44)
#85 T·Bar(14.,24,34,«)
lf22
ru
#24 TOP OUT D WASTE O WTR A/SUNDERGROUNDVISUAL
127 rue & SHOWER PAN A/S UNDERGROUND HYDRO
# TEST D GAS PIPING A/S UNDERGROUND FLUSH
A/S OVERHEAD VISUAL
A S OVERHEAD HYDROSTATIC
A/SFINAL
F AROUGH-IN
#600 PRE.CONSTRUCTION MEETING F/AANAl.
#603 FOLLOW OP UfSJ>fCTION AXED EXTINGUISHING SYSTEM ROUGH-IN
ff 05 NOTICE TO CI.EAN FIXED EXTlNG SYSTEM HYDROSTATIC TEST
#607 WRITJIH WARNING FIXED EXTIHGUISIMG S'iSTEM ANAL
#609 NOTICE OFVIOlATION 'MEDICAL GAS PRESSURE TEST
#810 VERBAL WARNING MEDICAL GAS FINAL
Rf.V 10/2012
· ('city of
Carlsbad
Cll~CUIT CARD
,I .,. 8-36
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
THIS CARD MUST BE FILLED OUT AND AV All.ABLE AT THE SER.VICE;;.----, FOR TifE ROUGH INSPECTION
Add~:"-z~ ~:r,,~~ Pennlt Number. CJ /fl 2-78'
Owner. _,,;., LI ;( ;fo M. .C = ,J I Phone: ~'ft) J'I I· I Ud Area In Sq. Ft eootractor: s v1 .i;t,,.. ~ 1. I~ Me I Phone: l.JC"/
PANEL: rz,,.;;;-)ck(' , J(_o A.LC. -Z.t.. vf VOLTS 0 WIRE
LOCATION CKT BKR WIRE MISC REC REC LTG MISC WIRE BKR LOCATION SIZE SIZE TYPE SIZE TYPE SIZE CKT
1 \ l '-{ "H-U+).) IS-2 ~luP
1-~ f,I. Ql-/-iq_ 3 l,r I "1 fl#l.ll 1 If,. t . I-<-{ I I 15" 4 () <;i._c,., &.~
~ ..... flf'\C, 5 '1...:, IL. If l{ I 1 L{ II (5"' 8 r,c.-Cb""iL
fMi. r,~ 7 --t,J l 1.,. ( I • '{ -:s -z_ \ It{ fl i 5"' 8 c:,~.
,it\--r1~i:-9 . "'l,.o {~ I C 4-7.-i;-8 -1../ 7'-1 ,t tz,' 10 ~f-{~
l.4,.,,..l i..A 11 -t-v I 1,.. ' I ii ( 1., ~ ~ ll.i II ,, 12 1,/(C..J l.x-/ i/iJJJ:t
\)\,It r(), 13 --1.-a ,,,_ '< .r ( \ t) , i:.,( le ~ 14 ~ (. //;c.,/£ C.
\L~~~ 15 ,v, I '1.. I< -z., t LtJ I'-( (I t< 18 tLJt-/S'~
{AV 17 u ( t.--ti I ~, , z.1~ le./ I( /) 18 ~~~
Afr_ 19 -µ, I 't.. ,_ .. C, & L 'i /1 t< 20 -a..,.._,t.., ~1-1.
Jr-/C 21 "1,.P ( 't-Vt . °"' er l t.( ll tL.. 22 ~ "-1/f-k.
kit 23 v,--/0 (c 'I,. tO \'1_ d l'l 24 S'Dl'lf, fl.
A-/ c.. 25 i.,:") {~ "' 26
27 28
29 30
31 32
33 34
35 36
37 38
39 \ 40
41 42
MAIN: ~ Goo AMP BRK/FUSE O MLO Computed Load AMPS
BUS: ~..,.p AMP See Calaultttlon W~ on back
Service l!lfllrance or feeder conductora: Branch clrculta requ Ired:
A) Size: No. B) Type: D cu D AL A) Lighting Circuits 220 -3(b), 4(d)
B) Two Small Appliance Circuits 210-11(&}
C) lnsulatlon: D) Coodult Size: C) Laundry Circuit 220-18(b)
Service ground/bond:
B) Type: ~ 0 AL
D) Central Heating Equipment 422-12
A) Size: No. -Z./.p E) Bathroom 210 • 52(d)
~mp locatlon(s):
ER 250-50(c) Remarks:
D Water Pipe 250-104
D Ground Rod 250-52
D
GFCl ~lions 210-8, 680-70:
~chen
I certify that all terminations have been torqued In acc6rdancs wtth manufacturer's
~throom(s) Jnstructlons and that the work shown an this circuit card repr888flts the full extent of
~arage(s) OHydromassage Tub the work performed under th/3 permit.
utdoors D D Owner
AF~tected Ciro. 210 -12 'D Contractor 5f v
-z---tC..-lf Bedroom(s) 1 D Signed -4Y--Date ,r
8-38 Page 1 of 2 Rev. 03/09
SINGLE FAMILY DWELLING
ELECTRICAL SERVICE LOAD CALCULATION
As an alternative method, the STANDARD METHOD
found In ARTICLE 220 of the National Electric Code, may be used
1. GENERAL LIGHTING LOADS
Dwelling sq. ft. x 3 VA= 220-3(a) ·· VA
Small appliance loads -220-16(a) 1500 VA x circuits= VA
Laundry load-220-16(b) 1500 VA x circuits= , VA
· General Lighting Total VA
2. COOKING EQUIPMENT LOADS -Nameplate Value
Range VA= VA
Cooktop VA= VA
Oven (s) VA= VA
.Cooking Equipment Total VA
3. ELECTRIC DRYER 220-18 (Nameplate, 5000 VA minimum)
Dryer VA= Dryer Total . VA
4. FIXED APPLIANCE LOADS 230-30 (b) (3)
Dishwasher =
Disposal=
Compactor=
Water Heater =
Hydromassage Bathtub =
Microwave Oven =
Built-In Vacuum = =
5. OPTIONAL SUBTOTAL (Add all of the above totals}
6. APPL YING DEMAND FACTORS -TABLE 220-30
First 10,000 VA x 100% =
Optional Subtotal (from line 5) { Remaining ___ VA x 40%=
7. HEATING OR AC LOAD -TABLE 220-30
Larger of the Heating or AC Load =
____ VA
____ VA
____ VA·
____ VA
____ VA
____ VA
____ VA
____ VA
Fixed Appliance Total ____ VA
____ VA
10,000 VA
VA ----
____ VA
8. OPTIONAL LOADS TOTAL (Add totals from lines 6 and 7} = ____ VA
9. MINIMUM SERVICE SIZE = Optional Loads Total = ____ Ampere
. 240 Volt
(Please put total on front of card under Computed Load)
'I • ,. ,.
t <
Co11ti1111011s l11spectlon & Materials Testing
S·oUTHWEST••••••••••••••• · · vvvvvv~vvvvvvvv
Inspection & Testing, Inc. 441 Commercial Way. Ln Habra, CA 90631-6168
(562) 941-2990 • (714) 526-8441
FAX(562)946-0026
February 18, 2016
Building Official
City of Carlsbad .
Department of Buildlng and Safety
1635 Faraday Ave
Carlsbad, Callfomia 92008
SPECIAL INSPECTOR'S FINAL PROJECT REPORT
Project Name: Seagrove Townhomes
Address:
Owner:
State Street, PH 3 Building 5
Taylor Morrison
Lot# Address Permit
G--i--2-555-stare-Street-e B1.-S1--2-'18t
32 2551 State Street CBT51285
33 2547 State Street CB15l2S4
34 2543 State Street CB1512S3
35 2539 State Street CB151282
Lot#
36
37
38
39
Address
2535 State Street
2531 State Street
2527 State Street
2523 State Street
Permit
CB151281
CB151280
CB151279
CB151277
This is to certify that Southwest Inspection and Testing, Inc. was employed to perform special Inspection on
the above mentioned project at the above address, which required continuous Inspection per section 1701 of
2013 California Building Code.
Brett Albllnger -Reinforced Concrete, Post Tensioned Concrete, SD #656
Neil White -Reinforced Concrete, Post Tensioned Concrete, ICC #5254958
Jeff Robertson-Reinforced Concrete, Post Tensioned Concrete, ICC # 5218723-92
Based upon special Inspection and materials testing written reports of this work, It Is our judgment that
the Inspected work was performed to the best of our knowledge, in accordance with the approved plans,
specifications and applicable workmanship provision of the California Building Code.
Steven L. G
President
SLG/IRW: amc
Reviewed By:
Ian R. Waddell, P.E.
Principal Engineer
ct