Loading...
HomeMy WebLinkAbout2556 La Costa Ave; ; CBR2019-0943; PermitResidential-Permit Print Date: 01/31/2020 Job Address: Permit Type: 2556 La Costa Ave BLDG-Residential 2163601100 $14,800.00 Work Class: Cogen Parcel No: Lot#: Valuation: Reference #: Occupancy Group: Construction Type: # Dwelling Units: Bathrooms: Bedrooms: Orig. Plan Check#: Plan Check#: Project Title: Description: ROOF MOUNT PV: 37 MODULES, 11.lKW BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) MANUAL BUILDING PLAN CHECK FEE Owner: CR CE D TREATMENT INC 2556 La Costa Ave CARLSBAD,CA 92009 581473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL Total Fees: $330.98 Total Payments To Date: $330.98 {city of Carlsbad Permit No: CBR2019-0943 Status: Applied: Issued: Permit Finaled: Closed -Finaled 04/22/2019 07/16/2019 Inspector: TAlva Final Inspection: 1/31/2020 1:37:27PM Contractor: HIGH POWER ELECTRICAL CONTRACTING INC 2551 Amherst St La Verne, CA 91750-3004 909-376-3261 Balance Due: $0.00 $159.31 $111.52 $57.23 $1.00 $1.92 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest.the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov (cicyof Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 PC Deposit --------- Date _"f.L.-•Z.C,""""",,_-_.l---'9'--- Job Address z 55lo LA ws--rP-Suite: ____ APN: _________ _ CT /Project#:. _________ Lot#:, ____ Fire Sprinklers: yes / no Air Conditioning: yes / no BRIEF DESCRIPTION OF WORK: _..;:S=e,.Oc:,LA--1<...=-..,..:.=c.___...;P___,V __________________ _ □ Addition/New: _____ Li,ving SF, ___ Deck SF, ___ Patio SF, ____ G.arage SF Is this to create an Accessory Dwelling Unit? Yes/ No New Fireplace? Yes/ No, if yes how many? __ D Remodel: ____ SF of affected area Is the area a conversion or change of use ? Yes/ No □ Pool/Spa: ____ SF Additional Gas or Electrical Features? ___________ _ l'A Solar: ! I. I KW, ~odules, Mounted: (§JI Ground, Tilt: Yes/~ RMA: Yes @Battery: Yes {tii) Panel Upgrade: Yes~ D Reroof: ___________________________________ _ D Plumbing/Mechanical/Electrical Only: _______________________ _ D Other: ------------------------------------ APPLICANT (PRIMARY CONTACT) Name: DAy' ID <$I.JD 'N Address: legs N ~c.£, City: s&l D//'Yl.A<; State: Cf'.'.\ Zip: Cl Ills Phone: C)Ljtj (e02--0031 Email: :e.voo,osolar-C\8(Yltul ,( ar0 DESIGN PROFESSIONAL Name: ________________ _ Address: _______________ _ City: _______ State:. _ _.Zlp: ---- Phone: ________________ _ Email: ________________ _ Architect State License: __________ _ PROPERTY OWNER Name: A(A]> I A Address: 2 55k LA cnsn--1 Oty: Cf¥2:L_S($/H) State: CA Zip: 9 2095 Phone: B 55 51 0 -l \o'.2-:Y Email: Ca<\,sh:ir;\ \Q CT)6Q-\CCO-:_-t-\()\" CQYY) CONTRACTOR BUSINESS Name: H:J bl:± :foi,A.182. fa ,Gc,.::f1<..j ffi < Address: (ff\ 'S W @£? A:f-6 D 12_ Oty: :sfu.} ]) I l'Y\ ftS State: QB Zip: Cj I ] ] 3 Phone: O\.t\g &/82 -6031 Email: 6\K{S(,l/\sQ\a,r 0-80JQ,,~\, lf5YY/ State Ucense:C!S$s83 Bus. Llcense:ap,at 1, d (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to Its Issuance, also requires the applicant for such permit to file a signed statement that he/she is llcensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 700) of Division 3 of the Busfness and Professions Code} or that he/she Is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov 8-1 Page 1 of 2 Rev. 06/18 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury Q!2f. of the following declarations: □ I have and will maintain a certificate of consent to self·Jnsure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is Issued. □ I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit rs Issued. My workers' compensation Insurance carrier and policy number are: Insurance Company Name: ____________________ _ Policy No. _____________ Expiration Date: _________ _ 'IS Certificate of Exemption: I certify that in the performance of the work for which this permit is Issued, I shalt not employ any person In any manner so as to be come ~li'bJect to the workers' compensation Laws of Callfornfa. WARNING: Failure to secure workers compensation coverace Is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100 addition the tot cost of compensation, dama1es as provided for In Section 3706 of the Labor Code, Interest and attorney's fees. ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License law for the following reason: □ I, as owner of the property or my employees with wages as their sole compensation, wlll do the work and the structure is not Intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and who does such work himself or through his own employees, provided that such Improvements are not intended or offered for sale. If, however, the building or improvement Is sold within one year of completion, the owner~bullder will have the burden of proving that he did not build or improve for the purpose of sale). □ I, as owner of the property, am excluslvely contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who buflds or Improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law), □ I am exempt under Section _______ ,Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No 2. I (have/ have not) signed an appllcation for a bulldlng permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (Include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (Include name/ address/ phone/ contractors' license number): S. I wlll provide some of the work, but I have contracted (hired) the followlng persons to provide the work Indicated (include name/ address/ phone/ type of work): OWNER SIGNATURE: __________________ □AGENT DATE: _____ _ CONSTRUCTION LENDING AGENCY. IF ANY: I hereby affirm that there Is a construction tending agency for the performance of the work this permit is Issued (Sec. 3097 {I) Clvll Code). Lender's Name: ___________________ _ Lender's Address: ___________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future bulldlng occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES ANO THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that l have read the application and state that the above information Is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the Otyof carlsbad to enter upon the above mentioned property for Inspection purposes. J ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY JN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit Is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories In height. 1635 Faraday Ave Carlsbad, CA 92008 B-1 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of 2 Email: Building@carlsbadca.gov Rev. 06/18 PERMIT INSPECTION HISTORY REPORT (CBR2019-0943) Permit Type: BLDG-Residential Application Date: 04/22/2019 Owner: Work Class: Cogen Issue Date: 07/16/2019 Subdivision: Status: Closed -Finaled Expiration Date: 01/13/2020 Address: IVR Number: 18557 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Checklist Item BLDG-Structural Final BLDG-Electrical Final January 31, 2020 COMMENTS January a, 2020 -no plaque/labeling at exterior electrical service panel. No photos of roof PV solar combiner box/J-box. Contractor rep. Could not verify existing UFER ground or will require additional ground rod for existing 200 amp electrical main service panel. January 8, 2020 -no plaque/labeling at exterior electrical service panel. No photos of roof PV solar combiner box/J-box. Contractor rep. Could not verify existing LIFER ground or will require additional ground rod for existing 200 amp electrical main service panel. CR CED TREATMENT INC LA COSTA-SOUTH UNIT# 1 2556 La Costa Ave Carlsbad, CA 92009-7321 Reinspection Complete Passed Yes Yes Page 2 of2 PERMIT INSPECTION HISTORY REPORT (CBR2019-0943) Permit Type: BLDG-Residential Application Date: 04/22/2019 Owner: Work Class: Cogen Issue Date: 07/16/2019 Subdivision: Status: Closed -Finaled Expiration Date: 01/13/2020 Address: IVR Number: 18557 Scheduled Date Actual Start Date Inspection Type Inspection No. 01/08/2020 01/08/2020 BLDG-35 Solar Panel 115618-2020 01/31/2020 January 31, 2020 BLDG-Final Inspection Checklist Item BLDG-Building Deficiency 115617-2020 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Structural Final BLDG-Electrical Final BLDG-35 Solar Panel 118088-2020 BLDG-Final Inspection Checklist Item BLDG-Building Deficiency 118087-2020 Inspection Status Primary Inspector Failed Tony Alvarado COMMENTS January 8. 2020 -no plaque/labeling at exterior electrical service panel. No photos of roof PV solar combiner box/J-box. Contractor rep. Could not verify existing UFER ground or wm require additional ground rod for existing 200 amp electrical main service panel. Failed Tony Alvarado COMMENTS January 8, 2020 -no plaque/labeling at exterior electrical service panel. No photos of roof PV solar combiner box/J-box. Contractor rep. Could not verify existing UFER ground or will require additional ground rod for existing 200 amp electrical main service panel. January 8, 2020 -no plaque/labeling at exterior electrical service panel. No photos of roof PV solar combiner box/J-box. Contractor rep. Could not verify existing UFER ground or will require additional ground rod for existing 200 amp electrical main service panel. January 8, 2020 -no plaque/labeling at exterior electrical service panel. No photos of roof PV solar combiner box/J-box. Contractor rep. Could not verify existing UFER ground or will require additional ground rod for existing 200 amp electrical main service panel. Scheduled Tony Alvarado COMMENTS January 8, 2020 -no plaque/labeling at exterior electrical service panel. No photos of roof PV solar combiner box/J-box. Contractor rep. Could not verify existing UFER ground or will require additional ground rod for existing 200 amp electrical main service panel. Passed Tony Alvarado C RC E D TREATMENT INC LA COSTA-SOUTH UNIT# 1 2556 La Costa Ave Carlsbad, CA 92009-7321 Reinspection Reinspection Passed No Reinspection Passed No No No No Passed No Complete Complete Complete Incomplete Complete Page 1 of 2 DATE: May 2, 2019 JURISDICTION: Carlsbad ✓• EsG1I A SAFEbutlt Company PLAN CHECK#.: CBR2019-0943 PROJECT ADDRESS: 2556 La Costa Ave. SET: I PROJECT NAME: Acadia Healthcare 37 Module PV System □ APPLICANT □ JURIS. [8J The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: [8J EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: ~ {') Telephone#: Date contacted: y~ ) Email: Mail Telephone In Person 0 REMARKS: By: Kat Frankowski EsGil Enclosures: 4/25/2019 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Kat Frankowski BUILDING ADDRESS: 2556 La Costa Ave. BUILDING OCCUPANCY: PLAN CHECK#.: CBR2019-0943 DATE: May 2, 2019 BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code #NIA ------------------· 1997 UBC Building Permit Fee .... 1997 UBC Plan Chc:.•c::.ck-'-'Fec.::.e ___ ..,._J] Type of Review: □ Complete Review O Repetitive Fee 3 Repeats * Based on hourly rate D Other [;] Hourly EsGil Fee Reg. VALUE Mod. D Structural Only .--___ 1_.-151 Hrs.@* $90.00_ Comments: In addition to the above fee, an additional fee of$ $ /hr.) for the CalGreen review. ($) $13s.001 is due ( hour@ Sheet of