Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2558 GLASGOW DR; ; CBRA2016-0036; Permit
Residential Associated Permit Print Date: 07/01/2019 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2558 Glasgow Dr BLDG-Associated Permit Residential 2081910100 $525,671.59 1 3.00 THE BLUFFS Work Class: Lot#: Reference#: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Single Family Detached 35 DEV2D16-0D71 VB 3.50 PC15DD74 PC2D16-D064 Description: THE BLUFFS: PHASE 5 // PLAN 1 // 3,282 SF// 425 GARAGE// 340SF CA ROOM// 159 SF PATIO Applicant: MIKE STEFFEN 725 W Town And Country, Ste 200 ORANGE, CA 92868-4723 760-729-2929 FEE BUILDING PERMIT FEE $2000+ BUILDING PLAN CHECK FEE (BLDG) COMMUNITY FACILITIES DISTRICT (CFD) FEE ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK Owner: RANCHO COSTERA LLC -2483-INACTIVE 725 W Town And Country Rd, 200 ORANGE, CA 92868-4723 714-347-1300 MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -inside CFO SB1473 BUILDING STANDARDS FEE SDCWA SYSTEM CAPACITY CHARGE 5/8" Displacement SEWER BENEFIT AREA FEES -B SEWER CONNECTION FEE (General Capacity all areas) STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1-Medium TRAFFIC IMPACT Residential Single Family w/in CFO TRAFFIC IMPACT Residential Single Family w/in CFO WATER METER FEE 1" Displacement WATER SERVICE CONNECTION FEE 5/8" DISPLACEMENT (P) WATER TREATMENT CAPACITY CHARGE 5/8" Displacement Total Fees: $34,126.79 Total Payments To Date: Building Division $31,246.79 Ccityof Carlsbad Permit No: CBRA2016-0036 Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: Balance Due: Closed -Finaled 12/30/2016 D2/24/2017 D6/24/2019 AKrog D6/24/2D19 AMOUNT $2,115.00 $1,362.06 $2,858.17 $96.DO $166.00 $110.00 $224.00 $9,567.22 $22.00 $5,029.00 $1,255.00 $899.00 $68.34 $232.00 $2,880.00 $2,740.00 $362.00 $4,013.0D $128.00 $2,880.00 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov PERMIT INSPECTION HISTORY REPORT (CBRA2016-0036) Permit Type: BLDG-Associated Pemiit Residential Application Date: 12/30/2016 Owner: RANCHO COSTERA LLC - 2483-INACTIVE Work Class: Single Family Detached Issue Date: 02/24/2017 Subdivision: Status: Closed -Finaled Expiration Date: 08123/2017 Address: 2558 Glasgow Dr Carlsbad, CA 92010-5602 IVR Number: 1176 Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date 03/21/2017 BLDG-21 017822-2017 Passed Andy Krogh Complete Underground/Underf loor Plumbing BLDG-22 017824-2017 Passed Andy Krogh Complete Sewer/Water Service BLDG-84 Rough 025725-2017 Passed Andy Krogh Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers BLDG-Final 095513-2019 Passed Chris Renfro Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes Exterior receptacles need weather foam gasket on cover plates. Gas piping on exterior needs to be extended 03/15/2017 03/15/2017 BLOG-SW-Pre-Con 016676-2017 Passed Andy Krogh Complete 04/06/2017 04106/2017 BLDG-11 019151-2017 Passed Andy Krogh Complete Foundation/Ftg/Pler s (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 05/05/2017 05/05/2017 BLOG-15 022453-2017 Passed Andy Krogh Complete Roof/ReRoof (Patio) 06/01/2017 06/01/2017 BLOG-18 Exterior 025018-2017 Passed Andy Krogh Complete Lath/Drywall 06/07/2017 06/07/2017 BLOG-17 Interior 025733-2017 Withdrawn Andy Krogh Reinspection Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No June 24, 2019 Page 1 of 2 PERMIT INSPECTION HISTORY REPORT (CBRA2016-0036) Permit Type: BLDG-Associated Permit Residential Application Date: 12/30/2016 Owner: Work Class: Single Family Detached Issue Date: 02/24/2017 Subdivision: Status; Closed -Finaled Expiration Date: 08/23/2017 Address: IVR Number: 1176 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector BLDG-18 Exterior 025558-2017 Failed Andy Krogh Lath/Drywall Checklist Item COMMENTS BLDG-Building Deficiency 1/Vrong code 06/20/2017 06/20/2017 BLOG-82 Drywall, 026677-2017 Passed Andy Krogh Exterior Lath, Gas Test, Hot Mop Checklist Item COMMENTS BLDG-Building Deficiency BLDG-17 Interior Lath-Drywall BLDG-18 Exterior Lath and Drywall BLDG-23 Gas-Test-Repairs 08/17/2017 08/17/2017 BLDG-Electric Meter 031967-2017 Falled Andy Krogh Release Checklist Item COMMENTS BLDG-Building Deficiency Not ready 08/18/2017 08/18/2017 BLOG-Electrlc Meter 032154-2017 Failed Chris Renfro Release Checklist Item COMMENTS BLDG-Building Deficiency Not ready 08/21/2017 08/21/2017 BLOG-Electrlc Meter 032300-2017 Passed Chris Renfro Release Checklist Item COMMENTS BLDG-Building Deficiency 09/05/2017 09/05/2017 BLDG-Final Inspection 033648-2017 Failed Chris Renfro June 24, 2019 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final COMMENTS AC disconnect need plastic bushing where wire enter in back. Add silicone to AC disconnect No power to 2 receptacles in master bathroom. Exterior receptacles need weather foam gasket on cover plates. Gas piping on exterior needs to be extended RANCHO COSTERA LLC - 2483-INACTIVE 2558 Glasgow Dr Carlsbad, CA 92010-5602 Re inspection Relnspectlon Passed No Passed Yes Yes Yes Yes Reinspectlon Passed No Relnspection Passed No Passed Yes Reinspection Passed No No No No No Complete Complete Complete Complete Complete Complete Complete Page2of2 PERMIT INSPECTION HISTORY REPORT (CBRA2016-0036) Permit Type: BLDG-Associated Pennit Residential Application Date: 12/30/2016 Owner: RANCHO COSTERA LLC - 2483-INACTIVE Work Class: Single Family Detached Issue Date: 02/24/2017 Subdivision: Status: Issued -Active Expiration Date: Address: 2558 Glasgow Dr Carlsbad, CA 92010 IVR Number: 1176 Scheduled Actual Inspection Type Inspection Status Primary Inspector Reinspection Complete Date Start Date Inspection No. 03/21/2017 BLDG-21 017822-2017 Passed Andy Krogh Complete Underground/Underf loor Plumbing BLDG-22 017824-2017 Passed Andy Krogh Complete Sewer/Water Service BLDG-84 Rough 025725-2017 Passed Andy Krogh Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 03/15/2017 03/1512017 BLDG-SW-Pre-Con 016676-2017 Passed Andy Krogh Complete 04/06/2017 04/06/2017 BLDG-11 019151-2017 Passed Andy Krogh Complete Foundation/Ftg/Pier s (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 05/05/2017 05/05/2017 BLDG-15 022453-2017 Passed Andy Krogh Complete Roof/ReRoof (Patio) 06/01/2017 06/01/2017 BLOG-18 Exterior 025018-2017 Passed Andy Krogh Complete Lath/Drywall 06/07/2017 06/07/2017 BLOG-17 Interior 025733-2017 Withdrawn Andy Krogh Relnspectlon Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-18 Exterior 025558-2017 Failed Andy Krogh Reinspectlon Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Wrong code No 06/20/2017 06/20/2017 BLDG-82 Drywall, 026677-2017 Passed Andy Krogh Complete Exterior Lath, Gas Test, Hot Mop June 21, 2019 Page1of2 ; ~~ ~'ii,.. W CITY OF CARLSBAD Building Division INSPECTION RECOR[ • "' . ' "' • • I CBRA2d 16-0036 ~!5s~u~~~~s~ B~A~i~ 3,282 SF 11 425 GARAGE /1340 SFCA ROOM// 159 SF PATIO • I • • 11 1; -• • ... ' • • --• I -• • • II • • • I I • If ''YES" is checked below that Division's apptoval is required p_tiqctQ_t~ uesting a Final Building Inspection. ff you have any questions please call the applicable divisions at the phone numbers provided below. After all required approvals are signed off-fax to 760-602-8560, email to blclginspectio11s@carlslrndc;1.gov or bring in a COPY of this card to: 1635 Faraday Ave., Carlsbad. m!lmll ··-· ··-· ilDI Required Prior to Requesting Building Final If Checked YES Planning/Landscape CM&I (Engineering Inspections) Fire Prevention ··-· --■ Type of Inspection #12 REINFORCED STEEL ~6 MASONRY PRE GROUT □GROUT □ WALL DRAINS #10 TILT PANELS #11 POUR STRIPS #11 COLUMN FOOTINGS #14 SUBFRAME □ FLOOR □ CEILING #15 ROOF SHEATHING #13 EXT. SHEAR PANELS #16 INSULATION #18 EXTERIOR LATH #17 INTERIOR LATH & DRYWALL #51 POOL EXCA/STEEL/BOND/FENCE #55 PREPLASTER/FINAL #22 □ SEWER & BL/CO □ PL/CO #21 UNDERGROUND □WASTE □ WTR #24 TOP OUT □ WASTE □ WTR #27 TUB & SHOWER PAN #23 □ GAS TEST □ GAS PIPING #25 WATER HEATER #28 SOLAR WATER #29 FINAL CODE" STORMWAl'ER .~ PRE-CONSTRUCTION MEETING 760-944-8463 Allow 48 hours 760-438-3891 Call before 2 pm 760-602-4660 Allow 48 hours Type of Inspection #34 #33 #35 PHOTO VOLTAIC #53 ELEC/CDNDUIT/WIRING #39 FINAL #82 ·DRYWALL,EXT LATH, GAS TES (17,18,23) #63 ROOF SHEATING, EXT SHEAR (13,15) #84 FRAME ROUGH COMBO (14,24,34,44) T-Bar(14,24,34,44) FINAL OCCUPANCY {19,29,39,49) A/S UNDERGROUND VISUAL A/S UNDERGROUND HYDRO A/S UNDERGROUND FLUSH A/5 OVERHEAD VISUAL A/S OVERHEAD HYDROSTATIC A/SFINAL F/ARDUGH•IN F/AFINAL Date Inspector t:'../- Date 1.ns ector \.,,,...,.ai<J3 FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN #605 NDTICETO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST #607 WRlmN WARNING FIXED EXTINGUISHING SYSTEM FINAL #609 NOTICE OF VIOLATION MEDICAL GAS PRESSURETEST #610 VERBAL WARNING MEDICAL GAS FINAL