Loading...
HomeMy WebLinkAbout2561 STATE ST; ; CB152709; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 02 -18-2016 Residential Permit Permit No: CB152709 Building Inspection Request Line (760) 602-2725 Job Address:2561 STATE ST CBAD Permit Type:RESDNTL Sub Type: CONDO Status:ISSUED Parcel No:2030543411 Lot #:11 Applied: 08/20/2015 Valuation:$295,759.00 Constuction Type: 5B Entered By: JMA Occupancy Group:Reference #: CT130005 Plan Approved: 02/18/2016 # Dwelling Units:1 Structure Type: MF5+Issued: 02/18/2016 Bedrooms:0 Bathrooms:0 Inspect Area: PY Orig PC #: PC140037 Plan Check #: PC150047 Project Title:STATE ST. TOWNHOMES: PHS 5 C1 405 SF 1ST FLR COMMERCIAL/1,694 SF LIV/ 476 SF GAR/ 67 SF BALCONY/ 585 SF ROOF DECK Applicant:Owner: TAYLOR MORRISON OF CA, LLC STE 1450 100 SPECTRUM DR IRVINE CA 92618-4935 949-341-1289 Building Permit $1,317.94 Meter Size FS1 Add'I Building Permit Fee $0.00 Add'I Red. Water Con. Fee $0.00 Plan Check $922.56 Meter Fee $317.00 Add'I Plan Check Fee ($500.00)SDCWA Fee $4,800.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $38.45 PFF (3105540)$5,382.81 Park in Lieu Fee $6,190.00 PFF (4305540)$4,968.75 Park Fee $0.00 License Tax (3104193)$0.00 LFM Fee '$0.00 License Tax (4304193)$0.00 Bridge Fee $0.00 Traffic Impact Fee (3105541)$0.00 Other Bridge Fee $0.00 Traffic Impact Fee (4305541)$0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BTD #3 Fee $0.00 PLUMBING TOTAL $210.00 Renewal Fee $0.00 ELECTRICAL TOTAL $89.00 Add'I Renewal Fee $0.00 MECHANICAL TOTAL $65.38 Other Building Fee $0.00 Housing Impact Fee $0.00 HMP Fee $0.00 Housing InLieu Fee $0.00 Pot. Water Con. Fee $3,931.00 Housing Credit Fee $0.00 Meter Size FS1 Master Drainage Fee $0.00 Add'I Pot. Water Con. Fee $3.00 Sewer Fee $881.00 Red. Water Con. Fee $0.00 Additional Fees $202.00 Green Bldg Stands (SB1473) Fee $12.00 Fire Sprinkler Fees $0.00 Green Bldg Stands Plan Chk Fee $0.00 TOTAL PERMIT FEES $28,830.89 Total Fees:$28,830.89 Total Payments to Date:$28,830.89 Balance Due:$0.00 /L FINAL PPR VA Inspector:).01i.L.Date:3 2s Jo 7 Clearance: NOTICE:Please take NO•T1 /approval of your project indudes the "I 'ion"fees,deli ions, reservations, or other exactions hereafter odlectively referred to as T"fees/exactions 'Y have 90 days Trull the date this permit i to protest imposition of these fees/exactions.If you protest tlx5ii, you must etfdlow the protest procedures forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Munidpal Cede Section 3.32.030.Failure to timelyfdlow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTI-ER NOTIFIED that your right to protest the spedfied fees/exactions DOES NOT APPLY to water and sewer connection fees and capadty changes, nor planning, zoning, grating or other similar application processing or service fees in connection with this project.NOR DOES IT APPLY to any fees/exactions of With Yeti have Previously been given a NOTICE sirrila-to this. or as to which the statute of 'irritations has previously otherwise expired. .•-•...••.,.. ... • • •••• • •PERMIT INSPECTION HISTORY REPORT1CB1527091 .•••...:.•••'• •• .•.•...•.••.,• Permit Type:BLDG-Residential Application Date:08/20/2015 Owner: Work Class:Condo Issue Date:02/18/2016 Subdivision: Status:Closed -Finaled Expiration Date:09/01/2017 Address:2561 State St Carlsbad, CA IVR Number:708715 Scheduled Actual Date Start Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete 11/09/2016 11/09/2016 BLDG-15 000392-2016 Passed Paul York Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 11/21/2016 11/21/2016 BLDG-13 Shear 002034-2016 Failed-Construction Paul York Reinspection Complete Panels/HD (ok to Change Needed wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 11/28/2016 11/28/2016 BLDG-13 Shear 002926-2016 Failed Paul Burnette Reinspection Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 11/30/2016 11/30/2016 BLDG-13 Shear 003494-2016 Failed-Construction Paul York Reinspection Complete Panels/HD (ok to Change Needed wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 12/01/2016 12/01/2016 BLDG-13 Shear 003751 -2016 Passed Paul York Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 12119/2016 12/19/2016 BLDG-84 Rough 006084.2016 Passed Paul York Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 12/28/2016 12/28/2016 BLDG-17 Interior 007276-2016 Failed-Construction Paul York Reinspection Complete Lath/Drywall Change Needed Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-23 007275.2016 Passed Paul York Complete Gas/Test/Repairs March 28, 2017 Page 1 of 2 •PERMIT INSPECTION HISTORY REPORT (CB152709) Permit Type:BLDG-Residential Application Date:08/20/2015 Owner: Work Class:Condo Issue Date:02/18/2016 Subdivision: Status:Closed -Finaled Expiration Date:09/01/2017 Address:2561 State St Carlsbad, CA IVR Number:708715 .....---.- Scheduled Actual Date Start Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency No 01/03/2017 01/03/2017 BLDG-17 Interior 007902-2016 Passed Paul York Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-23 007903-2016 Passed Paul York Complete Gas/Test/Repairs Checklist Item COMMENTS Passed BLDG-Building Deficiency No 01/09/2017 01/09/2017 BLDG-18 Exterior 008796-2017 Passed Paul York Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No 02/14/2017 02/14/2017 BLDG-Electric Meter 013546-2017 Failed-Construction Paul York Reinspection Complete Release Change Needed Checklist Item COMMENTS Passed BLDG-Building Deficiency No 02/15/2017 02/15/2017 BLDG-Electric Meter 013761-2017 Passed Paul York Complete Release Checklist Item COMMENTS Passed BLDG-Building Deficiency No 03/20/2017 BLDG-Fire Final 017252-2017 Scheduled Dominic Fieri incomplete Checklist Item COMMENTS Passed FIRE-Building Final No 03/28/2017 03/28/2017 BLDG-Final 017918-2017 Passed Paul York Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes March 28, 2017 Page 2 of 2 Inspection List Permit#:CB152709 Type:RESDNTL CONDO STATE ST. TOWNHOMES: PHS 5 C1 405 SF 1ST FLR COMMERCIAL/1,694 SF L Date Inspection Item Inspector Act Comments 11/01/2016 17 Interior Lath/Drywall PY PA 10/27/2016 15 Roof/Reroof PD PA 10/11/2016 17 Interior Lath/Drywall PD PA 09/21/2016 17 Interior Lath/Drywall PY PA 08/29/2016 11 Ftg/Foundation/Piers PY AP 08/11/2016 21 Underground/Under Floor PY AP 08/11/2016 22 Sewer/Water Service PY AP Wednesday, March 29, 2017 Page 1 of 1 ciinti„„..„.„.Ap ed.on & materiat. Terting IISSOurnavvEST A.Al16 .A. A. A.446..AL Inspection & Testing.Inc.341 Commercial Way. La Habra. CA 90631 -6168 (562)941 -2990 • (714) 526-8441 FAX (562) 946-0026 December 12, 2016 Building Official City of Carlsbad Department of Building and Safety 1635 Faraday Ave Carlsbad, California 92008 SPECIAL INSPECTOR'S FINAL PROJECT REPORT Project Name:Seagrove Townhomes Address:Tract #CT13-05, PH 5 Building 2 Owner:Taylor Morrison Lot#Address Permit Lot#Address Permit 10 2557 State Street CB152706 14 2573 State Street CB152712 11.2561 State Street CB152709 15 2577 State Street CB152713 12 2565 State Street CB152710 16 2581 State Street CB152714 13 2569 State Street CB152711 17 2585 State Street CB152707 This is to certify that Southwest Inspection and Testing, Inc. was employed to perform special inspection on the above mentioned project at the above address, which required continuous inspection per section 1701 of 2013 California Building Code. Brett Alblinger -Reinforced Concrete, Post Tensioned Concrete, ICC #0881693 Bruce Gordon -Reinforced Concrete, Post Tensioned Concrete, ICC #1133732 Larry E Robertson -Reinforced Concrete, Post Tensioned Concrete, ICC #5090690 Based upon special inspection and materials testing written reports of this work, it is our judgment that the inspected work was performed to the best of our knowledge, in accordance with the approved plans, specifications and applicable workmanship provision of the California Building Code. Sincereii.Reviewed By: z. .0)\•\"D.9<<.1fle- .,41-,•so•„-z-..{-.1, 512 A.Az-.:CO41219 FricsAtK-E XP 3c5/-7 LT;,*./ ., .\\.__.,.S.2Vik..Steven L.Go&ey Ian R.Waddell,P.E.QF r41.1f*3 e4_President Principal Engineer SLG/IRW: amc For inspection and testing only. no design responsibility expressed or implied. CB152709 2561 STATE ST CITY OF STATE ST. TOWNHOMES: PHS 5 ClCARLSBADINSPECTION RECORD 405 SF 1ST FLR COMMERCIAU1,694 SF LIV/ 476 SFBuilding Division GAR/ 67 SF BALCONY! 585 SF ROOF DECK .INSPECTION RECORD CARD WITH APPROVED RESDNTL CONDO PLANS MUST BE KEPT ON THE JOB Lot#:11 TAYLOR MORRISON OF CA, LLC G3 CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION 0 FOR BUILDING INSPECTION CALL:760-602-2725 OR GO TO:isatimairkhgdgaiagyahadiga AND CLICK ON RECORD COPY "Req 'r.on DATE:i _ IF "YLS•IS (.FILCKLE)BELOW THAT DiviSioN:S APPROVAL IS REQUIRED PP101?1+'I.E-01;i SI IN.A FINAL Bull DING INSPECTION. IF you I-I .V./1"ANY Qurs I IONS.PI 1_.V..i_CALL THE APPLICAPI F.DIVP.ION'.Al TI IF PHONE Nu 0 HERS PROVIDE .D BELOW.Ai-.I ER ALL REQUIRED APPROVALS ARE SIGNED Orr -FAX 10 760-002-8560.EMAIL 10 I'I f ..EN-.PI .I If ff.E.c ARI .P +.0:'.f -1'v OR BRING IN A COPY OF THIS CARD TO:1035 FARADAY AVE.. CARLSBAD.CA 02003.BUILDING IN..pr.c.row.CAN BE:REACHED AT 760-602 -2_700 BETWEEN 7:30 AM -8:00 AM THE DAY OF YOUR INSPECTION. NO YES Required Prior to Requesting Building Final If Checked YES Date Inspector Notes XPlanning/Landscape 760-9448463 Allow 48 hours 4. L't4-1.Me._ - ../C .1 cm&I (Engineering inspections)760-438.3891 Call before 2 pmhiflaki <7.04Fire Prevention 760-6024660 Allow 48 hours 3 i1 1lilk-;144\ Type of f ••••Type of Inspection cot.4 BUILDING -. a •insp ••tor Com_1:ELECTRICAL Date I ••r #11 FOUNDATION J/kait 4 4.,#31 0 ELECTRIC UNDERGROUND 0 UFER #12 REINFORCED STEEL .#34 ROUGH ELECTRIC #66 MASONRY PRE GROUT #33 0 ELECTRIC SERVICE 0 TEMPORARY 4/1S1/ 7 40GROUT0WALL DRAINS #35 PHOTO VOLTAIC #10 TILT PANELS #39 FINAL #11 POUR STRIPS co..4 MECHANICAL #11 COLUMN FOOTINGS #41 UNDERGROUND DUCTS &PIPING #14 SUBFRAME 0 FLOOR 0 CEILING #44 0 DUCT&PLENUM 0 REF. PIPING #15 ROOF SHEATHING iiii 'ez Ap--' #43 HEAT-AIR COND. SYSTEMS #13 EXT. SHEAR PANELS 'A /.-#49 FINAL #16 INSULATION con.4 COMBO INSPECTION #18 EXTERIOR LAIN ii ,/7 Foir #81 UNDERGROUND (11,12,21,31) #17 INTERIOR LATH &DRYWALL 13 17 k..#82 DRYWALL,IEXT LATH, BASTES (17,18,23) #51 POOL IECCA/STEEL/BOND/FENCE #83 ROOF SHEATING, EXT SHEAR (13,15) #55 PREPLASTUVFMAL #84 FRAME ROUGH COMBO (14,24,34,44)/2//6)1.4/1„15.#18 FINAL #85 T•Bar (14,24,34,44) CO DE .4 PLUMBING Dat -Ins •ector #89 FINAL OCCUPANCY (19,29,39,49) #22 0 SEWER &B CO 0 CO 111111MIMIIIIIII FIRE Date Ins ••r #21 UNDERGROUND OWASTE 0 Will •f 6 #24 TOP OUT 0 WASTE 0 WTR A/S UNDERGROUND VISUAL #27 TUB &SHOWER PAN / A/S UNDERGROUND HYDRO #23 1:gTEST 0 GAS PIPING ip.i 7 1:1/A/S UNDERGROUND FLUSH #25 W HEATER A/S OVERHEAD VISUAL //if el /NMI #28 SOLAR WATER A/S OVERHEAD HYDROSTATIC i 17-A. #29 FINAL A/S FINAL 3 )ii 12~. CODE 44 STORM WATER F/A ROUGH-IN #600 PRE-CONSTRUCTION MEETING F/A FINAL #603 FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN 605 NOTICE TO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST #607 WRITTEN WARNING FIXED EXTINGUISHING SYSTEM FINAL #609 NOTICE OF VIOLATION MEDICAL GAS PRESSURE TEST #610 VERBAL WARNING MEDICAL GAS FINAL REV 10/2012 SEE BACK FOR SPECIAL NOTES 24 -6i sT4 te Development ServicesCity of CIRCUIT CARD Building Division Carlsbad B -36 •.1635 Faraday Avenue . . 760-602-2719 twww.carlsbadca.govo.1-I( THIS CARD MUST BE FILLED OUT AND AVAILABLE AT THE SERVICE EQUIPMENT FOR THE ROUGH INSPECTION Address:1.22 - (,9(,tilt4e.‘7\-1.20e•Permit Number: Owner:Phone:Area in Sq. Ft.Contractor:Phone: PANEL:A.I.C.I.1.Q VOLTS tti 0 0 VO WIRE BKR WIRE WIRE BKRLOCATIONCKTMSCRECRECLTGMISC CKT LOCATIONSIZESIZETYPESIZETYPESIZE ciOs tAil 1 k.0 14 /sAkwii k I{vt.Akko TO 2 p,ric rec. tAt14-wc 6 9-3 LC 14 A co I 0..._ \ 0 4 '"„. fr.o, . 7. (44-5 1 5'`'ti (.ct f)ID \I 1.45 6 1;c41,(//41.- 440/4k-tem 7 t '1 ki't C'‘5 t IA-11)8 COcAzaivc—.. “204/1101.A5 9 •V ItA r.i NI.7-0 10 A/C'- 6A-11 11 1 \d1 -1 I 11'-to 12 "Ve. 90.iliAttl...13 \k'\\<1_.ki.V 14 Its 1(VW. Liviru, (4.‘15 t<tk (0 ql 1 .A..td 16 114 C rl. tv4.9.04'17 (.,`C \kk I l0 t -fc 18 41C0cc.)14--cll.-)(.< -- 19 vk l \1/4) I V 'Lc- 20 /VC'3 fi -'4”I 21 22 ., 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 \40 .., 41 42 • MAIN:0 boo AMP BRK/FUSE 0 MLO Computed Load AMPS BUS:AMP See Calculation Worksheet on back Service entrance or feeder conductors:Branch circuits required: A) Size: No.V°B) Type:0 CU F(AL A) Lighting Circuits 220 -3(b), 4(d) B) Two Small Appliance Circuits 210 -11(e)C) Insulation:D) Conduit Size:C) Laundry Circuit 220 -16(b)Service ground/bond:0) Central Heating Equipment 422 -12 A) Size: No.Ve2 B) Type:eCU 0 AL E) Bathroom 210 -52(d) C) Clamp location(s):0 UFER 250 -50(c)Remarks:0 Water Pipe 250 -104 0 Ground Rod 250 -520 GFCI locations 210 -8, 680 -70:i certify that all terminations have been torqued in accordance with manufacturer's--E Bathroom(s)-`1:1 Kitchen instructions and that the work shown on this circuit card represents the full extent of---n,Garage(s)OHydromassage Tub the work performed under this permit. 1111 Outdoors 0 0 Owner AECI Protected Circ. 210 -12 0 Contractor A'AiPt e(ec •- ma Bedroom(s)0 Signed --......-.Date 1 L -f`f* If° -.. B-36 Page 1 of 2 Rev. 03/09 ------ SINGLE FAMILY DWELLING ELECTRICAL SERVICE LOAD CALCULATION As an alternative method, the STANDARD METHOD found in ARTICLE 220 of the National Electric Code, may be used 1.GENERAL LIGHTING LOADS Dwelling sq. ft. x 3 VA =220-3(a)VA Small appliance loads —220-16(a) 1500 VA x circuits =VA Laundry load —220-16(b) 1500 VA x circuits ='VA • General Lighting Total VA 2.COOKING EQUIPMENT LOADS —Nameplate Value Range VA =VA Cooktop VA =VA Oven (s)VA =VA Cooking Equipment Total VA 3.ELECTRIC DRYER 220-18 (Nameplate, 5000 VA minimum) Dryer VA =Dryer Total VA 4.FIXED APPLIANCE LOADS 230-30 (b) (3) Dishwasher =VA Disposal =VA Compactor =VA Water Heater =VA Hydromassage Bathtub =VA Microwave Oven =VA Built-in Vacuum =VA VA Fixed Appliance Total VA 5.OPTIONAL SUBTOTAL (Add all of the above totals)VA 6.APPLYING DEMAND FACTORS —TABLE 220-30 First 10,000 VA x 100%=10,000 VA Optional Subtotal (from line 5) { Remaining VA x 40%=VA 7.HEATING OR AC LOAD —TABLE 220-30 Larger of the Heating or AC Load =VA 8.OPTIONAL LOADS TOTAL (Add totals from lines 6 and 7)=VA 9.MINIMUM SERVICE SIZE =Optional Loads Total =Ampere 240 Volt (Please put total on front of card under Computed Load) BLDG 2 INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope —Insulation; Roofing; Fenestration (Page 1 of 3) Site Address:Enforcement Agency:Permit Number: LOT 11bEe94'STATE STREET.CB152709 Ifmore than one person has responsibilityfor installation ofthe items on this certificate, each person shall prepare and sign a certificate applicable to the portion ofconstructionfor which they are responsible; alternatively. the person with chief responsibilityfor construction shall prepare and sign this certificatefor the entire construction.All applicable Mandatory Measures with check boxes require to be checked to ensure the mandatory measures have been met. Description of Insulation I.RAISED FLOOR Material:Brand Name: Thickness (inches):N/A Thermal Resistance (R-Value): §150(d):Minimum R-13 insulation in raised wood-frame floor or equivalent U-factor. 2.SLAB FLOOR/PERIMETER Material:Brand Name: Thickness (inches):N/A Thermal Resistance (R-Value): Perimeter Insulation Depth (inches): §150(1):Water absorption rate for the insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 perm/inch and shall be protected from physical damage and UV light deterioration. 3.EXTERIOR WALL a.Insulation Type (e.x. Batt, Loose Fill, Spray Foam) 2X4 BATTS a.Thermal Resistance (R-Value):R-13 b..Insulation Type (e.x. Batt, Loose Fill, Spray Foam) 2X6 BATTS b.Thermal Resistance (R-Value):R-19 Brand:MANVILLE Spray/Loose fill)Installed Actual Thickness Spray/Loose fill) (inches):Contractor's min installed weight/ft2 lb Manufacturer's installed weight per square foot to achieve Thermal Resistance (R-Value) §150(c):Minimum R-13 insulation in wood-frame wall or equivalent U-factor. Exterior Foam Sheathing (rigid Insulation) Material:Brand Name: Thickness (inches):N/A Thermal Resistance (R-Value): 4.FOUNDATION WALL Material:Brand Name: Thickness (inches):N/A Thermal Resistance (R-Value): 5.CEILING Batt or Blanket Type:BATTS Brand Name:MANVILLE Loose Fill Type:Thermal Resistance (R-Value):R-30 Spray Foam Type:Brand Name: Installed Actual Thickness (inches):Contractor's min installed weight/ft'lb Manufacturer's installed weight per square foot to achieve Thermal Resistance (R-Value): §150(a):Minimum R-19 insulation in wood-frame ceiling or equivalent U-factor. 6.ATTIC ROOF INSULATION AND/OR ATTIC RADIANT BARRIER Material:Brand Name: Material:N/A Brand Name: Thickness (inches):Thermal Resistance (R-Value): §118(a):Insulation installed meets Standards for Insulating Material. §150(g):Mandatory Vapor barrier installed in Climate Zones 14 or 16. 2008 Residential Compliance Forms August 2009 RI f)G 2 INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope —Insulation; Roofing; Fenestration (Page 2 of 3) Site Address:Enforcement Agency:Permit Number: .LOT 11-2561 STATE STREET CB152709 Description of Roofing Products CRRC Product ID Manufacturer Product Roof Roof Product Initial Solar Aged Solar Thermal Number'Information Brand/Model Type Area Slope Weight=Reflectance Reflectance Emittance 03 N/A 1.The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Product Directory at — ww.coolroofs.orgProducts/search.php 2.The weight in lbs per square feet ofthe roofing product being installed 3 Check box ifthe Aged Reflectance is a calculated value using the equation below, footnote 4. 4.Ifthe aged reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the initial reflectance value from the directory and use the equation (0.2+0.7(p„nNi -0.2) to obtain a calculated aged value. DCHECKAPPLICABLE BOX BELOWIFEXEMPT FROM THE ROOFING PRODUCT "COOL ROOF" REQUIREMENT.'0 The roofarea covered by building integrated photovoltaic panels and building integrated solar thermal panels are exempt from the above Cool Roof criteria. 0 Roof constructions that have thermal mass over the roof membrane with a weight ofat least 25 lb/f)'is exempted from the above Cool Roof criteria. To apply Liquid Field Applied Coatings, the coating must be applied with a minimum dry mil thickness of20 mils across the entire roofsurface and meet minimum performance requirements listed in 5118(93 and Table 118-C.Select the applicable coating 0 Aluminum-Pigmented Asphalt Roof Coating I 0 Cement-Based Roof Coating I 0 Other 0 CRRC-1 Label Attached to CF-6R (Note ifno CRRC-I label is available, this compliance method cannot be used and another method is required to meet compliance). FENESTRATION/GLAZING Product ft Total Quantity Add. Exterior Comments/ Manufacturer/Brand Name U-Product of NFRC of Like Product Area Shading Dev.Location/ Special Item (GROUP LIKE RODUCTS)factor)SHGC)Panes Certified'.2 (Optional)ft2 or Overhang Features 1 2 3 4 N/A 5 6 7. 8. 1.Use valuesfrom a fenestration product's NFRC Certified Label. Fur fenestration products without an NFRC label,use the default values from Section 116. Table 116-A and 116-8 ofthe 2008 Energy Efficiency Standards. 2. NFRC Label Certificates shall not be removed until the building inspector has verified the efficiency. Enter Yes orNo. §116(a)1: Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. §116(a)2 and 3: Actual fenestration products installed are equivalent to or have a lower U-factor and/or a lower SHGC than that specified on the Certificate ofCompliance (Form CF-IR). §116(a)4: Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration that meets the requirements of §10-111(a) §117: Exterior doors and windows weather-stripped; all joints and penetrations caulked and sealed. 2008 Residential Compliance Fornis August 1009 BLDG 2 INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope —Insulation; Roofing; Fenestration (Page 3 of3) Site Address:Enforcement Agency:Permit Number: LOT 11-2561 STATE STREET CB152709 DECLARATION STATEMENT •1 certify under penalty ofperjury, under the laws of the State of California, the information provided on this form is true and correct. •I am eligible under Division 3 of the Business and Professions Code to accept responsibility for construction, or an authorized representative ofthe person responsible for construction (responsible person). •I certify that the installed features, materials, components, or manufactured devices identified on this certificate (the installation) conforms to all applicable codes and regulations, and the installation is consistent with the plans and specifications approved by the enforcement agency. •I reviewed a copy of the Certificate of Compliance (CF-I R) form approved by the enforcement agency that identifies the specific requirements for the installation.I certify that the requirements detailed on the CF-IR that apply to the installation have been met. •I will ensure that a completed, signed copy of this Installation Certificate shall be posted,or made available with the building permits)issued for the building, and made available to the enforcement agency for all applicable inspections.I understand that a signed copy of this Installation Certificate is required to be included with the documentation the builder provides to the building owner at occupancy. Company Name:(Installing Subcontractor or General Contractor or Builder/Owner) ROCKWELL DRYWALL, INC. Responsible Person's Name:Responsible Person's u - BUTCH INGRAM /444 CSLB License:Date Signed:Position With Company (Title): 956154 1/10/2017 VP OF OPERATIONS 2008 Residential Compliance Forms August 2009