Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2562 DOGWOOD RD; ; CB072095; Permit
09-20-2007 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Patio/Deck Permit Permit No CB072095 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Reference # Project Title 2562 DOGWOOD RD CBAD PATIO 2131701700 Lot# 0 $1,75500 Construction Type NEW VONHOFFMANN 195 SF PATIO CVR Applicant D A DOYLE CONSTRUCTION 966 CIMARRON TERR 92029 432-6160 Status Applied Entered By Plan Approved Issued Inspect Area Plan Check* Owner VONHOFFMANN CYNTHIA A 2562 DOGWOOD RD CARLSBAD CA 92009 ISSUED 08/08/2007 JMA 09/19/2007 09/19/2007 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Strong Motion Fee Renewal Fee Add'l Renewal Fee Other Building Fee Additional Fees TOTAL PERMIT FEES $3477 $000 $2260 $000 $1 00 $000 $000 $000 $000 $5837 Total Fees 358 37 Total Payments To Date $58 37 Balance Due $000 BUILDING PLANS IN STORAGE ATTACHED PERMIT H/-SFXPIP? SECTION 1&* « Ai Inspector FINA Date Clearance NOTICE Please take NOTICE that approval of your project includes the' Imposition' of fees, dedications, reservations, or other exactions hereafter collectively referred to as fees/exactions ' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you mu>t follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes nor planning, zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired City of Carlsbad 1635 Faraday Ave . Carlsbad, CA 92008 760-602-2717 / 2718 / 2719 Fax 760-602-8558 Building Permit Application Plan Check No O3O'~? Est. Value Plan Ck. Deposit Date 'JOB ADDRESS i CT/PROJECT f» 1 DESCRIPTION'OF WORK I UltML • SUITE#/SPACE»/UNIT# # BEDROOMS" # BATHROOMS TENANT BUSINESS NAME £13-no -_n: ICClNSTR T cooey SFl YPE OCC GROUP EXISTING USE PROPOSED USE GARAGE (SF)PATIOS (SF)DECKS (SF)FIREPLACE YESD #NOD AIR CONDITIONING YES n NO D FIRE SPRINKLERS YES D NO D CONTACT NAME (If DlfferenJ Fom Applicant)APPLICANT NAME ADDRESS CifV | PHONE""" ; EMAIL ADDRESS STATE ZIP CITY ^G6j_Qv\r\<x\riroA To/wa o- ZIP PHi EMAIL Ifco 7°S PROPERTY OWNER NAME I ADDRESS CONTRACTOR BUS NAME CA S'"E :PHONE I. EMAIL iFAX ADDRESS CITY PHONE j _ I—J STATE EMAIL ARCH/DESIG.NER NAME * ADDRESS STATE LIC #STATE LIC #CLASS (Sec 70315 Business and Professions Code Any City or County which requires a permit to construct alter, improve demolish or repair any structure, prior to IK issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law {Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031S by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}) Workers' Compensation Declaration / hereby affirm under penalty ol perjury one of the following declarations C] I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for (he performance of the work for which this pemit is issued 1ST I have and will maintain workers\tompensat|on as required by Section 3700 of the Labor Code for the performance otthewp/k for whichjhis permit is issued My workers compensation iterance tarrier and policy number are Insurance Co S> TA "rQ r^O^yyfQ __________ Policy No /fofc/^3 O C)~7 __ Expiration Date *'/3 / This section need no! be completed if the permit is for one hundred dollars ($100) or less O Certificate of Exemption I certify that in the performance of the^wortt-fflrwhich this permit is issued I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure-waiters' compensation cjjveragejs unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, darnagesas provided for ySstajeif3706 of the Labor code, interest and attorney's fees JS$ CONTRACTOR SIGNATURE iL. jO"O/<7 NT -—"" DATE / hereby affirm that I am exempt from Contractor s License Law for trie following reason n I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) D I as owner of the property am exclusively contracting with licensed contractors to construct the proiect (Sec 7044 Business and Professions Code The Contractor s License Law does not c'pply to an owner of property who builds or improves thereon and contracts for such propels with contractor(s) licensed pursuant to the Contractor s License Law) D I am exempt under Section _.Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement n Yes Cl No 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors license number) 4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone / contractors license number) 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work) ) PROPERTY OWNER SIGNATURE DATE | Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act7 O Yes Cl No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? O Yes O No i Is the facility to be constructed within 1 000 feet of the outer boundary of a school site'n Yes d No IF ANY OF THE ANSWERS ARE YES, / I EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT OFFICE OF I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code) Lender's Name Lender s Address ^ I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE UTY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required feretjcavatons over 5 0 de©WB«hlemolition or construction of structures over 3 stones in height EXPIRATION Every permit issueoxy (rebuilding Official undenmpro^ions of this Code shall expire by limitation and become null and void if the building or work authonzed by such permit is not commenced within 180 days from the date of such pefyit or if f\ie building ^ work ^itNgJl^d by such permit is suspended or abandoned at any time after the work is commenced/or a penod of 180 days (Section 106 4 4 Uniform Building Code) ) APPLICANT'S SIGNATUR1 DATE Inspection List Permit* CB072095 Type PATIO VONHOFFMANN 195 SF PATIO CVR Date Inspection Item !n^P^?r Act Comments 10/23/2008 14 Frame/Steel/Boltmg/Weldin PC Fl 09/25/2007 11 Ftg/Foundation/Piers PC AP Monday, October 27, 2008 Page 1 of 1 DATE 7L0O UNSCHEDULED BUILDING INSPECTION |o?r~ INSPECTOR PERMIT # Q*>3LH^ PLAN CHECK # JOB ADDRESS _ DESCRIPTION CODE DESCRIPTION ACT COMMENTS A EsGil Corporation In (Partnership with government for (RuMmg Safety DATE September 12, 2007 JURISDICTION City of Carlsbad PLAN CHECK NO CB072095 SET HIsup PROJECT ADDRESS 2562 Dogwood Ln. PROJECT NAME Trellis for the vanHoffrnann Residence O^APPUQANT (fjURIS a FILE X] The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to X] Esgil Corporation staff did not advise the applicant that the plan check has been completed I I Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Date contacted Mail Telephone REMARKS (by ) Fax In Person By Steve Sanders Esgil Corporation D GA D MB D EJ PC Telephone # Fax # Enclosures 9/12/07 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (858)560-1468 + Fax (858) 560-1.576 EsGil Corporation In (Partnership -with government for Quitting Safety DATE September 6, 2O07 a APPLICANT JURISDICTION City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO CB072O95 SET III PROJECT ADDRESS 2562 Dogwood Ln. PROJECT NAME Trellis for the vanHoffmann Residence The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck X3 The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to Daniel Doyle 966 Cimarron Ter Escondido, CA 92029 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted. Dan Doyle Telephone # (760) 432-6160 Date cortactedf/Y/^(by^65 Fax # (760)432-6193 Mail,/Telephone Fax S\n Person Cell (760) 703-3020 X3 REMARKS Sets II submitted before set I was plan checked By Steve Sanders Enclosures Esgil Corporation D GA D MB D EJ D PC 9/4/07 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 Ci,ty of Carlsbad CBO72O95 September 6, 2007 RECHECK PLAN CORRECTION LIST JURISDICTION City of Carlsbad PLAN CHECK NO CBO72O95 PROJECT ADDRESS 2562 Dogwood Ln. SET III DATE PLAN RECEIVED BY DATE RECHECK COMPLETED ESGIL CORPORATION 9/4/07 September 6, 2007 REVIEWED BY Steve Sanders FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit two new complete sets of prints to Esgil Corp ortothebldg dept of the juris B To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes QNo City of Carlsbad CB072O95 September 6, 2O07 Please make all corrections, as requested in the correction list Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete ESGIL CORPORATION received re-submitted plans on September 4, 2007. These plans are identical to the previously submitted plans. The original correction list was not included with the required comments where the corrections can be located on the plans The following items are from the original correction list and are still valid Please revise the plans, provide the required structural calculations, correction list and re-submit the plans for review. 1 All sheets of plans must be signed by the person responsible for their preparation (California Business and Professions Code) 2 Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 editions of the California Building/Plumbing/Mechamcal Codes and the 2004 edition of the California Electrical Code, which adopt the 1997 UBC, 2000 UMC, 2000 UPC and the 2002 NEC 3 Provide a fully dimensioned site plan drawn to scale Section 106 3 3 Include the following a) North arrow 4 Note on the plans the locations of smoke detectors a) Inside each bedroom b) Centrally located in corridor or area giving access to sleeping rooms 5 When the valuation of a room addition or repair exceeds $1,000, or when sleeping rooms are created, smoke detectors shall be provided per the above, except that smoke detectors added at existing construction need only be battery powered Section 31091 2 6 Provide calculations for horizontal framing members Section 106 3 3 Please provide structural calculations for the redwood cantilevered beam and the redwood 2 x 12's spanning 20'-4 1/2". City of Carlsbad CBO72095 September 6, 20O7 7 Please specify the fasteners connecting the CJT6 to the dwelling Provide the type and length of the fasteners Specify the type of structural member in the existing dwelling the CJT6 is proposed to connect to 8 The post/beam connection shown in detail B-1 shows the lag bolts to fasten into the "end" gram of the beam The Code allows no values for this type of connection To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes a No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Steve Sanders at Esgil Corporation Thank you EsGii Corporation In (Partnership with (government for (Ruitding Safety DATE August 21, 2007 a APPLICANT JURISDICTION City of Carlsbad a FILE PLAN CHECK NO CB072095 SET I & II PROJECT ADDRESS 2562 Dogwood Ln. PROJECT NAME Trellis for the vanHoffmann Residence The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck A) The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person X] The applicant's copy of the check list has been sent to Daniel Doyle 966 Cimarron Ter Escondido, CA 92029 Esgil Corporation staff did not advise the applicant that the plan check has been completed X] Esgil Corporation staff did advise the applicant that the plan check has been compleled Person contacted., Dan Doyle Telephones (760)432-6160 Date contactedJ/2/A?/ (by >/^ Fax # (760)432-6193 Mail Telephone. / Fax v'fn Person Cell (760) 703-30207, rv>)xj REMARKS Sets H! submitted before set I was plan checked By Steve Sanders Enclosures Esgil Corporation D GA D MB D EJ D PC August 13 & 20, 2007 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 4> (858)560-1468 * Fax (858) 560-1576 City of Carlsbad CB072095 August 21, 2O07 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO CB072095 JURISDICTION City of Carlsbad PROJECT ADDRESS 2562 Dogwood Ln. FLOOR AREA Trellis 195 sq ft STORIES 1 HEIGHT 9'-10" approx REMARKS DATE PLANS RECEIVED BY JURISDICTION 8/8/07 DATE INITIAL PLAN REVIEW COMPLETED August 21, 2007 DATE PLANS RECEIVED BY ESGIL CORPORATION August 13 & 20, 2007 PLAN REVIEWER Steve Sanders FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Present California law mandates that residential construction comply with the 2001 edition of the California Building Code (Title 24), which adopts the following model codes 1997 UBC, 2000 UPC, 2000 UMC and 2002 NEC The above regulations apply to residential construction, regardless of the code editions adopted by ordinance The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans City of Carlsbad CBO72O95 August 21, 2O07 Please make all corrections, as requested in the correction list Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete Important Notice Regarding the 2007 CBC If you are an architect, engineer, designer or contractor that performs work within the State of California, please be advised that a new building code will take effect on January 1, 2008 The new building code is based on the 2006 International Building Code (IBC) and it is significantly different than the Uniform Building Code (UBC) All plan review applications submitted after December 31. 2007 will be required to comply with the new code The 2007 CBC is currently available for purchase directly from the International Code Council, at www iccsafe org 1 All sheets of plans must be signed by the person responsible for their preparation (California Business and Professions Code) 2 Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 editions of the California Building/Plumbmg/Mechamcal Codes and the 2004 edition of the California Electrical Code, which adopt the 1997 UBC, 2000 UMC, 2000 UPC and the 2002 NEC 3 Provide a fully dimensioned site plan drawn to scale Section 106 3 3 Include the following a) North arrow 4 Note on the plans the locations of smoke detectors a) Inside each bedroom b) Centrally located in corridor or area giving access to sleeping rooms City of Carlsbad CB072095 August 21, 2007 5 When the valuation of a room addition or repair exceeds $1,000, or when sleeping rooms are created, smoke detectors shall be provided per the above, except that smoke detectors added at existing construction need only be battery powered Section 310 9 1 2 6 Provide calculations for horizontal framing members Section 106 3 3 Please provide structural calculations for the redwood cantilevered beam arid the redwood 2 x 12's spanning 20'- 41/2 ". 7 Please specify the fasteners connecting the CJT6 to the dwelling Provide the type and length of the fasteners Specify the type of structural member in the existing dwelling the CJT6 is proposed to connect to 8 The post/beam connection shown in detail B-1 shows the lag bolts to fasten into the "end" grain of the beam The Code allows no values for this type of connection To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans • Have changes been made to the plans not resulting from this correction list? Please indicate Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Steve Sanders at Esgil Corporation Thank you City of Carlsbad CB072O95 August 2.1, 2OO7 VALUATION AND PLAN CHECK FEE PLAN CHECK NO CB072095 DATE August 21, 2007 JURISDICTION City of Carlsbad PREPARED BY Steve Sanders BUILDING ADDRESS 2562 Dogwood Ln. BUILDING OCCUPANCY R-3 TYPE OF CONSTRUCTION VN BUILDING PORTION Trellis Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 195 cb Valuation Multiplier 887 By Ordinance Reg Mod VALUE ($) 1,730 • 1,730 $34 77 Plan Check Fee by Ordinance : ^ | Type of Review 0 Complete Review Repetitive FeeRepeats D Other r—I Hourly Structural Only Hour Esgil Plan Review Fee $2260 $1947 Comments Sheet 1 of 1 macvalue doc 000c c c D D PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No CB Planner Gma Ruiz Address Phone (760) 602-4675'i\*j _- n-oo Type of Project & Use Zoning p-£ General Plan j<UM CFD (m/out) #_Date of participation Net Project Density DU/AC Facilities Management Zone I 7 Remaining net dev acres Circle One (For non-residential development Type of land used created by this permit ) Legend < £3 Item Complete Q Item Incomplete - Needs your action Environmental Review Required YES NO \ TYPE DATE OF COMPLETION Compliance with conditions of approval? If not, state conditions which require action Conditions of Approval Discretionary Action Required APPROVAL/RESO NO PROJECT NO YES NO X" TYPE DATE OTHER RELATED CASES Compliance with conditions or approval? If not, state conditions which require action Conditions of Approval D DD Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES NO ^ CA Coastal Commission Authority? YES NO X If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402, (619) 767-2370 Determine status (Coastal Permit Required or Exempt) NO XHabitat Management Plan Data Entry Completed? YES _ If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees-in Permits Plus ,'.;., i .'> ,' , - ; (A/P/Ds/Aptivity'Maintenance, enter CB#, toolbar,;Screens, HMP Fees,.Enter Acres of Habitat Type impacted/taken, UPDATE') ' " ' ,>..,*-., NOInclusionary Housing Fee required YES _ (Effective date of Inclusionary Housing Ordinance - May 21, 1993) Data Entry Completed? YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE') H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 License Detail Page 1 of2 California Home ; VVelcome'to Wednesday, Aug License Detail Contractor License # 562601 CALIFORNIA CONTRACTORS STATE LICEN j DISCLAIMER \ A license status check provides information taken from the CSLB license data base Etefore ; on this information, you should be aware of the following limitations | • • CSLB complaint disclosure is restricted by law (B&P 7124 _6) If this entity is subject tc i complaint disclosure, a link for complaint disclosure will appear below Click on Ihe hn j button to obtain complaint and/or legal action information ! • Per B&P 7_Q71 II, only construction related civil judgments reported to the CSLB are ; disclosed : • Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration • Due to workload, there may be relevant information that has not yet been entered ont Board's license data base * * * Extract Date 08/08/2007 Business Information * * * DANIEL A DOYLE 966 CIMARRON TERRACE ESCONDIDO, CA 92029 Business Phone Number (760) 432-6160 Entity Sole Ownership Issue Date 03/29/1989 Expire Date 03/31/2009 * * *License Status * * * This license is current and active All information below should be reviewed. * * *Classifications * * * Class I Description B~~ |G ENERAL " BJUJLD J N * * *Bonding Information * CONTRACTOR'S BOND: This license filed Contractor's Bond number 6060267 in the air $12,500 with the bonding company http //www2 cslb ca gov/CSLB_LIBRARY/License+Detail asp 08/08/2007 License Detail Page 2 of2 * * * SURETY COMPANY OF THE PACIFIC. Effective Date 01/01/2007 Contractor's Bonding -History Workers Compensation Information * * * This license has workers compensation insurance with the STATE COMPENSATION INSURANCE FUND Policy Number 1669238 Effective Date 12/01/2002 Expire Date 12/01/2007 Workers CQmpensation_MstQry Personnel List I LicenseNumber Request •Contractor Name RequestTI •Personnel Na • Salesperson Request | Salesperson Name Request me Request © 2006 State of California Conditions of Use Privacy Policy http //www2 cslb ca gov/CSLB_LIBRARY/License+Detail asp 08/08/2007 6 0 S = ^ 1 ^ O ~ \l VN PI £0d(v,If.r ;oi j t** ^ V 3inm %, %sli :T3ni 7^ N •O,vi §«~o;OO! »|2< ofl»:s< iS3 I3m TJOJ ?^o|S S^^lliii>s|2«°Is^P Si i r- -o < or ^ c^' \ ;i ^Ji j ^^ s5 ^ ^ L w &S^o a> § ^ ug^- ~* I M O g:n« s > 105 w& o>Z ro «a O ^0W< i OD O) < m