HomeMy WebLinkAbout2562 LA COSTA AVE; ; 86-360; PermitI hereby affirm that I am licensed under
provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business
and Professions Code, and my license is in
full force and effect.
I hereby affirm that I am exempt from the Conlrac-
for's license law for the following reason (Sec. 7031.5
Business and Professions Cede: Any city or county which re'
quires a permit to censtruct, alter, yrlprove, demotish, or
repair any structure, prior to its issuance also requires the ap'
plicant tsr such permit to tile a signed statement that he is
licensed pursuant to the previsions of the Contractor's
License Law (Chapter 9 commencing with Section 7000 of ex—Division 3 of the Business and Professions Code) or that is empt therefrom and the basis fur the alleged exemplioo..Any
violation of Section 7031,5 by an applicant for a permit sub-
lects the applicant to a civil penalty of not more than tiveirun' .. dred dollars ($500).
It I. as owner of the property, or my employees with wages
as their sole compensation, will do the work, and the struc'
ture is not intended or offered for sale (Sec. 7044. Business
and Professions Code: The Contractor's license Law does
not apply to an owner 01 property who builds or improves
thereon and who does such work himself erihrough his own
employees, provided that such improvements are not intend-
ed ui uttered .Ini sale It, hOWever, the building or improve-
ment is sold within ene year of completion, the owner-builder -'
will have the burden of pruning that he did not haitdnr im-
prove for the purpose of sale).
I, as owner of the property, am exclusively contracting
with
as
contractors to construct the project (Sec. 7044.
Business and Professions Code: The Contractors License
Law does not apply loan owner 01 property who builds or im-
proves thereon, and who contracts or each projects with a contractor(s) license pursuant to the Contractor's License Law(.
As a homeowner I am. improving my home, and the fallow—
ing conditions exist:
t. The work is being performed prior to vale.
I have lived in my home for twelve months
prior to completion 01 this work.
I have not claimed this exemption during the
- . last three years. -
turn exempt under Sec. _________________ .5 & P.C.
for this reason '
I hereby affirm that I have a certificate of consent to
sell-insure. or a certificate or Workers' Compensation In-
surance. or a certified copy thereof (Sec. 3800. Labor Code)
POLICY NO.
COMPANY -
O Copy is tired wilh he city
Certified copy is hereby furnished
- --CERTIFtCATE OF EXEMPTION FROM
'WORKERS COMPENSATION INSURANCE
llhis.sectiOfl need not be completed irtpe,permit
- in for one hundred dollars ($100) or less)
0 i certify that in the performance of the work for which
this permit is issued. I shall not employ any person in any
manner so as to become subject to the Workers' Compen'
sation Laws of California.
'NOTICE TO APPLICANT: If. after making this Certificate
of Exemption, you should become subject to the Workers' -I
Compensation provisions of the Labor Code, you mu'st
lorthwith comply with such provisions or this permit shall,
be deemed revoked.
O I hereby affirm thbt there is a Construction tending
- 'agency for the performance of the work for which this per. I
0 mit is issued (sec. 3097, Civil Code) - Z J .Len4r'sName - -
Lender's Address
PEN ONLY & PRESS HARD - PRESS ------ APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS.
-
" CARLSBAD BUILDING DEPARTMENT APPLICATION & PERMIT
- Carlsbad, California 92008-4859
JOB ADDRESS AV. ST.RD. NEAREST CROSS ST. DATE OF APPLICATIONI BUSINESS LICENSE # , VALUATION PERMIT NUMBER
-''25Z . oST4 Ave- . //• ,
LOT BLOCK ' I SUBDIVISION ASSESSOR PARCEL NO. CONTRACTOR CONTRACTORS PHONE a ZONE
'53
eUi$yIt
qJA,,J f'( OWNER'S NAME - ., OWNER'S PHONE
BUILDING SO. FOOTAGE
.. pe,3n.e714-( fo1j.i'.I 1 75 iSS— CONTRACTOR'S ADDRESS STATE LICENSE NO.
OWNER'S MAILING ADDRESS
- 7 G, DESIGNER DESIGNER'S PHONE
DESCRIPJ 0 OF OR
i.4 d1L. St AJ4 c'( DESIGNER'S ADDRESS - STATE LICENSE NO. .
____ ---------.-- .-.'-' F/P NO 0CC OP EDU ..r 7ij.j6.
STORIES .
YD ND
PARKING
7FLRELEV,
SPACE RESUNITS GRADING PERMIT ISSUED. REDEVE ENT TVPE DC LO D FIRE SPA
N o
AREA
-- -
10 p:.1 J' 0 Not Valid Unless Machine Certified
-
QTY. PLUMBING PERMIT- ISSUE 7- QTY. MECHANICAL PERMIT - ISSUE 3 -
SUMMARY/ACCOUNT NUMBER
EACH'FIXTUR,E..TRAP 7-.!!-- / INSTALL FURN. DUCTS UP TO 100.000 BTU g - BUILDING PERMIT 001-810-00-00-8220
EACH BUiLUtNGS,EW.ER -, OVER 100,000 BTU , SIGN PERMIT 001-810-00-00-8221 -
EACH &TER HEATER AND/OR VENT BOILER/COMPRESSOR UP 3 HP I- • PLAN CHECK 001-810-00-00-8806 -
EACH GAS SYSTEM I 104 OUTLETS BOILER/COMPRESSOR 315 HP , TOTAL PLUMBING 001'810-00-00'8222 ________
,
EACH GAS SYSTEM 5'0 R MORE - . METAL FIREPLACE ' ELECTRICAL 001-810-00-00-8223
EACH INSTAl.., ALTER, REPAIR WATER PIPE . VENT FAN SINGLE DUCT - ' -- MECHANICAL 001:8100000.8224 /4
EACH VACUUM BREAKER
- -
_/ MECH EXHAUST - HOOD/DUCTS MOBILEHOME 001-810-00'00'8225
WA.TEI3 SOF.TNER - . RELOCATION OF EA FURNACE/HEATER . .- SOLAR 001-810-00'00-8226
EACH ROOF- DRAIN (INSIDE'(l- - - DRYER VENT - -
V ' STRONG MOTION 880'519-92-33
— —t
TOTAL MECHANICAL
. . 'I - -
FIRE SPRINKLERS 001-810-00-00-8i27
TOT.A'L.PL'UMBING (.0/ .-' PUBLIC FACILITIES FEE'7A__320'810'0O'00'8740
-
BRIDGE FEE' -
QTY -' ELECTRICAL PERMIT- ISSUE
5
OTY, MOBILE HOME SETUP PARK-IN-LIEU (AREA
NEW'COPJST EA AMP/SWT/BKR.r-2O ,f11lp5 CAR PORT - . TIF 001-10-00-00-8835 ..
f -PH - - - .-- 3 PH - ' . AWNING . LICENSE TAX e3,001'810'00-00'8162
EXIST BLDG EA AMP/SWTIBKR •_. - . GARAGE - - . MFF Q,Q 880-519-92-57
IPH ( `3 PH
— REODEL'A1T-E.R, PER-CIRCUIT
TEMP POLE 200 AMPS
— OV'ER'200 AMPS
— TEMP OCCUPANCY (30 DAYS)
--CREDIT DEPOSIT ' -->--
TOTAL ELEIfRICAL ...- TOTAL TOTAL FEES PAYABLE60 ' -
I HAVE CAREFULLY EXAMINED THE COMPLETED '-APPLICATION AND PERMIT" AND DO HEREBY - Expiration. Every permit I
Code shall expire by a e Ing Official under the provisions of this * AN OSHA PERMT IS REQUIRED FOR EXCAVATIONS OVER
CERTIFY UNDER pEfIALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE authorized by such
me null 5nd O iin
U the building Or
ys en 180 a from the date
1wOr
such 50" DEEP AND DEMOLITION OR COSTRUCTION OF
DECLARATIOPJS'ARE TRUE AND CORRECT AND I FURTHER CERTIFY AND AGREE IF A PERMIT IS permit. or if the bubldino authorized by such frmt is suopended or STRUCTURES OVER 3 STORIES IN HEIGHT
ISSUED: TO COMPLY WITH ALL CITY, COUNTY AND STATE LAWS GOVERNING BUILDING CON aban ad 81 anytime 'work is commenced for a period of 180 days
- STRUCTION, WHETHER SPECIFIED HEREIN OR NOT. I ALSO AGREE TO SAVE INDEMNIFY AND NATU KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND=;~Iq
APPR OWNER Li CONTRACTOR -' - ' ' - -- w$i. OA'LJ 'a
EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE BY PHONE 0 NI' GRANTING OF THIS PERMIT.
-
ITEMS ABOVE HAVE BEEN APPROVED
FINAL
PLUMBING
ELECTRICAL I
-
MECHANICAL
GAS
-L ii
BUILDING
SPECIAL CONDITIONS
. -.--
I
.TYPE
-
DATE INSPECTOR
BUILDING
FOUNDATION _________ PECTION RECORD
REINFORCED STEEL
FIELD IN
SREQUIRED
-
SPECIAL INSPECTIONS INSPECTORS
MASONRY I INSPECTION REQ. IF
CHECKED
INSPECTORS
APPROVAL DATE - ,. GUNITE OR GROUT
SUB FRAMEFLOOR LI CEILING
. 7' SOILS COMPLIANCE ..
SHEATHING LI ROOF LI SH:EAR PRIOR TO
I FRAME g4_ 77
Q
FOUNDATION INSP
STRUCTURAL CONCRETE
EXTERIOR LATH I OVER 2000 PSI
INSULATION I PRESTRESSED
CONCRETE
INTERIOR LATH & DRYWALL POST TENSIONED -
CONCRETE
PLUMBING -. ________ .
FIELD WELDING
LI SEWER AND BLICO LI PL/CO (%4/J' p HIGH STRENGTH
BOLTS
UNDERGROUND LI WASTE LI WATER
TOP OUT LI WASTE LI VVATER
SPECIAL MASONRY -
TUB AND SHOWER PAN
GAS TEST I /17 y4/t 7' PILES CAISSONS -
LI WATER HEATER LI SOLAR WTER
I
ELECTRICAL
LI ELECTRIC UNDERGROUND L UFFER
ROUGH ELECTRIC I
'- LI ELECTRIC SERVICE 1TEMPRARY 1,V.ic/ai
I LI BONDING LI POOL
-
•
m,Qr' LjO1L?
MECHANICAL
LI DUCT & PLEM., LI REF. PIPING ,I4,f/p( 7'
HEAT - AIR COND. SYSTEMS
VENTILATING SYSTEMS
flQ MiAI INPP3IflN WHEN .ALL APPROPRIATE
i"-i. ri7?i1
5.- ..
FINAL BUILDING INSPECTION
. S •' S.
PLAN CHECK NUMBER: 86360
PROJECT NAME:
2562 La Costa yrl
DATE:
VPZ
.
.
617-87
-. PROJECT NO.: I UNIT NUMBER: PHASE NO.: Ih-
TYPE OF UNIT: afd ._- NUMBER OF UNITS: I -
-
CONTACT PERSON: Ioboti
CONTACT TELEPHONE: 7530980
all dept
INSPECTED DATE - -
BY:
S - INSPECTED: APPROVED DISAPPROVED
INSPECTED .-DATE
BY: INSPECTED: APPROVED DISAPPROVED
INSPECTED • DATE - -'- -
BY: . INSPECTED: APPROVED ______ DISAPPROVED
COMMENTS:
79-9 f -
- S
Rev. 1/86 WHITE: Suspense BLUE: Water District GREEN: Eninee CANARY: Utilities PINK: Planning GOLD: Fire
-' FINAL BUILDING INSPECTION
*
).. .
PLANCHECK NUMBER: .86-360 , -. DATE: 617-87
PROJECT NAME:
ADDRESS: 2562 La Costa -
PROJECT NO:: UNIT NUMBER: PHASE NO.:
TYPE OF UNIT: sfd NUMBER OF UNITS:
CONTACT PERSO N: Hobson
CONTACT TELEPHONE: 753-0980
all deDt
INSPECTED DATE JUL 0 9 197
INSPECTED: APPROVED DISAPPROVED .,p._...
INSPECTED S . DATE -
BY: INSPECTED: APPROVED DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
(osra seal Municipal Water District
COMM'ENTS: Engineering Department
(619)438-3367
/ S
- - t
C'
Rev. 1/86 WHITE:
SusPen
oBLUE:WaterDis ct GREEN Engineering CANARY Utilities PINK Planning GOLD Fire
-. ...4 s 1_•• -
FINAL BUILDING INSPECTION
PLAN CHECK NUMBER: 86-360 DATE:
PROJECT NAME:
TYPE OF UNIT: sfd NUMBER OF UNITS:
CONTACT PERSON: Hobson
CONTACT TELEPHONE: 7530980
ADDRESS: -
2562LaCosta
PROJECT NO.: UNIT NUMBER: PHASE NO.:
all dept
BY:
INSPECTED --r4z INSPECTED: b/i/i7 APPROVED DISAPPROVED
INSPECTED1)
altlz d) ATE
INSPECTED: APPROVED V" DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
COMMENTS: 5,ét'LD thv/vi
j3,4 cR '4DSD, g y,i'V41)4
C £27 /Jo 7 LD S&LE (?4
/4'_#4-NP?(7 '4if_O)9LP./iV5
7(& CLfA41a ? t4&5 L e4 7-,ci7
Rev. 1/86 WHITE: Suspense BLUE: Water Distri GREE N: Engineerin'NARY: Utilities PINK: Planning GOLD: Fire
ESGIL CORPORATION
9320 CHESAI'EAKE DR.. SUITE 208
SAN DIEGO, CA 92123
-
(619) 5G0•1468
DATE: /'s a V — — 9 APPLICANT
JURISDICTION: CT 4 --=PLAN CHECKER
9 FILE COPY
PLAN CHECK NO: ,.. 3 9UPS
9 DESIGNER
PROJECT ADDRESS:
PROJECT NAME:
__ The plans transmitted herewith have been corrected where• necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified . - are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
Eli identified on the enclosed check list and should be corrected
and resubmitted for .a complete recheck.
The checklist transmitted herewith isfor'yöürinforfrtation.
El . The plans are being held at Egil Corp. until corrected
plans are submitted for recheck.
El The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
/ The applicant's copy of the check list has been sent to:
El Esgil staff did not advise the applicant contact person that
plan check has been completed.
zm Esgil staff did advise-applicant that the plan check has
been completed. Person contacted: t4c. (.'
Date contacted:' \_ Telephone #73-o1YO
REMARKS: T-
By: Si Enclosures: No
Datei_i-&' Jurisdiction 4kb&cI
Prepared .byi, 0 Bldg. Dept.
VALUATION AND PLAN CHECK FEE 'ESgi1
PLAN CHECK NO. 9&- 5eoc
BUILDING ADDR ES S _.5/ ,.
APPLICANT/CONTACT M. PHONE NO. o'jo
BUILDING OCCUPANCY )", DESIGNER PHONE -
TYPE OF CONSTRUCTION Z'J CONTRACTOR PHONE____________
BUILDING PORTION BUILDING AREA VALUATION
MULTIPLIER
VALUE
Air Conditioning
Commercial 0
0
-Residential
Res. or Comm. :
Fire Sprinklers
0
Total Value 0
Fee Adjusted To Reflect 0 Energy Regulations (Fee x 1.1)
0 Handicapped Regulations (Fee x 1.065)
8u11di66 Permit Fee. $_ _0
Plan Check Fee $ 0
0$
COMMENTS: 0
8/4/82
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(6 19) 560- 1468
DATE: SePT
JURISDICTION: CT _________________________________ PLMFTBECKER
flFILE COPY
Li PLAN CHECK NO: (p UPS
LJDESIGNER
PROJECT ADDRESS: C.oT tk_
PROJECT NAME:
I The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
fl with the jurisdiction's building codes when minor deficien-
cies identified - are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies S identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
Eli The
The check list transmitted herewith is for your. information.
plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
Li The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person..
The applicant's copy of the check list has been sent to:
E Esgil staff did not advise the applicant contact person that
plan check has-been completed.
Esgil staff did
been
advise applicant that the plan check has
completed. Person con tacted:.'ohsi
Date contacted: J8I'I Telephone #_
\Fl EMARKS: I
By: Enclosures: A)(I
ESGIL C01PORATION
a - o
ESGIL CORPORATION
9320 CIIESAI'EAKE DR.. SUITE 208
SAN DIEGO, CA 92123
(619) 560- 1468
LF1t / OiGQ DATE:
IURISDCT]
JURISDICTION: CT o
----
EJ FILE 'COPY
PLAN CHECK UPS
DESIGNER
PROJECT AD7SS:
PROJECT
U The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
U with the jurisdiction's building codes when minor deficien-
cies identified - are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies U identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is for your information.
The plans are being -held at Esgil Corp. until corrected
plans are submitted for recheck.
E The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
(/( 4rro ,
('
U Esgil staff did not advise the applicant contact person that
plan check has been completed.
Esgil staff did advise applicant that the plan check has
- been completed. Person contacted: hr.
Date contacted: 91,11&, Telephone # 7S- o10 U REMARKS:
By: Ac2) Enclosures:
ESGIL CORPORATION
PLAN CHECK NO: 3CcJ1
JURISDICTION:(T I'1 t2L' O APPLICANT COPY
O JURISDICTION COPY
O PLAN CHECKER COPY o FILE COPY
Ewl".40-
Enclosures:
LLi
b1ri. # ,L. -.
w( tb- _ctLt ioor5:Ze.
)'/,S LrL
(7) P.e ___'r-- rT\ __ &••e-
Skct4j isc'ilT'.. iet _ )
cf-t _t'rov
ujcji__, _d
1T Purti5—
___ t-s u9(-w
-
A
u i
''4 J L)
# \4 eetr ___kiOJ }-
____ N
&wa\-S.p
*flTh la '4_Pa
U
.
i k rø.,,'rte
t17
'kL'&,,rders vdr4Joor1T a...
____
r
4 1784
PROJECT ADDRESS:_
TO: /1'r. bor. 7 (;32 ('a Z-
-t' df-' , (' viç i-,.,,,-1,
Date plans received byjurisdictionq//.
Date plans received by plan checker______
Date initial plan check
• FORWARD:PLEASEREAD
Plan check is limited to technical requirements
contained in the Uniform Building Code,. Uniform
Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy
conservation, noise attenuation and access, for
the handicapped. The plan check is based on
regulations enforced by the Building Inspection
Department. You may have other corrections
.based on laws and ordinances enforced by the
Planning' Department, Engineering Department
or other departments.
'The items circled below need clarification,'
modification or change. All circled items have
to be satisfied before the plans will be in
conformance with the cited codes and regulations.
The approval of the plans does not permit the
violation of any state,' county or city law.
A. PLANS
Please make all corrections on the original
tracings and subjnit two new sets of prints,
and any original plan sets that may have
been returned to you by' the jurisdiction,
to:
(J /?0 facilitateckj'1 ease ldentj)
next to each circled item, the sheet of
the plans upon which each correction on
( this sheet has been made and return this
check sheet with the revised plans. ...-
:-
-
L1
PISnT -Tt. is e--IdOvtfl..
'Y 9cA CeyTrc t or
11 -Put e-4-- Crc,eT1 CC- 4-op 4nua. iseT
50- er$$ AS7 /'Por77) 77Z 4Io
7tZ Pser3 6'fl4 71:P).,7-:5,dD 1" -
c&a -
ESGIL CORPORATION
9320 CHESAPEAKE DR.. SUITE 208
SAN DIEGO, CA 92123
(619) 5601468
SI
DATE: .Auu5-- •I \ J(7
JURISDICTION: CITY OF CARLSBAD
PLAN CHECK NO: -
PROJECT ADDRESS: Z
PROJECT NAME:
PLAN CHECKER
FILE COPY
UPS
DESIGNER
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is the jurisdiction's
copy for your information. The plans, are being held at
Esgil Corp. until corrected plans are submitted for recheck.
E The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
s. CiIl' 1-1rlr (ik 11.
Esgil staff did not advise the applicant contact person that
plan check has been completed.
Esgil staff did advise applicant that the plan check has
been completed. Person contacted: Mr. iô
Date contacted: Telephone cD 0i
REMARKS:
BY: A'IE ENCL:
ESGIL CORPORATION
The circled items need clarification,
modification or change. All items have to be
satisfied before the plans will be in
conformance with the cited codes and
regulations. Per Sec. 303 (c), 1982 Uniform
Building Code, the approval of the plans does
not permit the violation of any state, county AjoI
or city law.
To speed up the recheck process, note on this
list (or a copy) where each correction item has
been addressed i.e., plan sheet, specification.
etc. Be sure to enclose the marked up list
ywhen ou submit the revised plans.
5p e. c 1cc. (.( \.J" Pt- 1t r%.Adt.
Date plans received by jurisdiction:
Date plans received by Esgil Corporation:
6'
PLAN == NO. YG- Date initial plan check completed:
JURISDICTION: CITY OF CARLSBAD
TO: Ce, It C-
ede
TELEPHONE NO. 7S3 _cY)Vo
PROJECT ADDRESS: .L.. C. S I Z.
/..)iI ' By:
Applicant contact person:
Telephone: 7S I SC)
FOREWORD: PLEASE READ
Plan check is limited to technical requirements
contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code,
National Electrical Code and state laws
regulating energy conservation, noise
attenuation and access for the handicapped.
The plan check is based on regulations enforced
by the Building Inspection Department. You may
have other corrections based on laws and
ordinances enforced by the Planning Department,
Engineering Department or other departments.
Present California law mandates that
residential construction comply with Title 24
and the following model codes:
1982 UBC (eff. 7/1/85)
1982 UPC (eff. 10/1/85)
1984 NEC (eff. 10/1/85)
1982 UMC (eff. 3/1/85)
The above regulations apply to residential
construction, regardless of the code editions
adopted by ordinance.
Carlsbad List 10, Single Family Dwelling and Duplex With All Supplements
1
3/25/86
A. PLANS
1. Please make all corrections on the original
racings and submit two new sets of prints, and
any original plan sets. that may have been
returned to you by the jurisdiction, to:
Esgil Corporation, 9320 Chesapeake Drive,
Suite #208, San Diego, California 92123,
(619) 560-1468.
Please make all corrections on the original
tracings and submit two new sets of prints, and
any original plan sets that may have been
returned to you by the jurisdiction, to:
The jurisdiction's building department.
Indicate on the Title Sheet of the plans,
/the name of the legal owner and name of person
responsible for the preparation of the plans.
Section 302 (a) 7.
/Plans, specifications and calculations shall
be signed by a California state licensed
engineer or architect. (California Business and
Professions Code).
j Specify on the Title Sheet of the plans the
'gross floor area of each element of this project
including dwelling, garage, carport, patio, deck
and balcony. Section 302 (c).
/ Provide a statement on the Title Sheet of
'the plans that this project shall comply with
Title 24 and 1982 UBC, UMC, and UPC and 1984
NEC.
Submit fully dimensioned plot plan drawn to
scale showing location, size, and use of all
existing and proposed structures on the lot.
Identify property lines and show lot dimensions
and all easements. Show location of all cut or
fill slopes and approximate finish floor
elevations for all structures and show
elevations at all lot corners.
Section 302 (c).
2
3/25/86
Indicate distance from center line of street
or alley to property line and distance from
property lines to proposed building.
Section 302 (c).
B. FIRE PIYIION
Walls closer than 3 feet to property lines
shall be one-hour rated construction, have no
openings, and shall have 30 inch parapets when
the building floor area exceeds 1,000 square
feet on any floor.
(Table 5. A. Section 1709 (a)).
yL Projections, including eaves, may not
extend more than 12 inches into the 3 foot
setback from the property line. Eaves over
required windows shall be not less than 30
inches from the side and rear property lines.
Section 1710 and Section 504 (a) and (b).
i4 Plastic skylights shall not be installed
in 8' of an exterior wall located where
openings in such exterior wall are prohibited or
required to be protected.
Section 5207 (a) 7.
l Projections, including eaves, shall be
tone-hour fire-resistive construction, heavy
timber or of noncombustible material if they
project into the 3' setback area from the
property line. Section 1710.
Show location of permanently wired smoke
detector, centrally located in corridor leading
to sleeping rooms or above stair if sleeping
rooms are on upper level. Section 1210.
e A smoke detector shall be installed in the
ment of dwelling units having a stairway
which opens from the basement into the dwelling.
Such detector shall be connected to a sounding
device or other detector to provide an alarm
which will be audible in the sleeping area.
Section 1210.
C. ROOM SIZ, LI(, VENrILAlION AND GLAZING
Habitable rooms, other than kitchens, shall
/contain at least 70 square feet of floor area.
Section 1207 (b).
Window area must be at least 1/10 of the
"floor area and a minimum of 10 square feet per
Section 1205 (a). Appears to be deficient in
}'i. Openable window, area in habitable rooms
/must be 1/20 of the floor area and a minimum' of
5 square feet. In bathrooms, laundry rooms and
similar rooms 1/20 of area is required and
minimum is 1.5 sq. ft. (Section 1205 (a)).
At least 1/2 of the common wall must be
open and have an opening not less than 25 sq.
ft. if light and ventilation is being supplied
from an adjacent room. Section 1205 (a).
Required windows shall not open into a
"roofed porch unless the ceiling is at least 7
feet and the longer side is at least 6596 open
Section 1205 (a).
Provide mechanical ventilation capable of
providing five air changes per hour in
bathrooms, water closet compartments, laundry
rooms and similar rooms if required openable
windows are not provided. Section 1205 (a).
7 1(. No habitable room, other than a kitchen,
shall be less than 7'0" in any dimension.
Section 1207 (c).
Show that-ceiling height for habitable
'rooms is a minimum of 7'611 . Section 1207 (a).
11- Show ceiling height for laundry rooms,
hallways, corridors, and bathrooms is a minimum
of 7,011 . Section 1207 (a).
3
3/25/86
Dimension on the plans, the 30" clear width
for water closet compartments and 24" clearance
in front of water closet.
Section 511 (a).
e . Specify safety glazing for glazing in
zardous locations such as glass doors, glazing
adjacent to such doors and glazing adjacent to
walking surfaces. Section 5406.
Glazing, in the same wall plane as a door,
'must be safety glazing if within 12" of the door
and less than 60" above the walking surface,
unless the glazing is leaded on faceted glass.
Section 5406 (d) 7.
Glazing in shower and tub enclosures shall
be tempered, laminated or approved plastic
(including windows within 5 feet of tub or
shower floor). Section 5406 (d) 5.
Sleeping rooms shall have a window or
exterior door for emergency exit. Sill height
shall not exceed 44" above the floor. The
window must have an openable area of at least
5.7 square feet with the minimum openable width
20" and the minimum openable height 24".
Section 1204.
201. A mezzanine is an intermediate floor and
,ay not have a floor area exceeding 33 1/3
percent of the total floor area in the room
below. The mezzanine floor must have a clear
height of 7 feet, above and below, and must have
the long side open to the room below except for
posts and protective walls or railings not
exceeding 42" in height. Section 1716.
The loft you show does not comply as a
Ziezzanine floor and is, by Uniform Building Code
definition, a story. Section 1716.
/
D. rrs • STADAYfS • AND RAILINGS
Floors above the second story shall.have
not less than 2 exits. Section 3303 (a).
Required exit doorways shall be not less
fthan 36" in width and not less than 61 8" in
height, and shall be capable of opening at least
90 degrees. Section 3304 (e).
Provide 36" high protective railing for
porches, balconies, and open sides of stair
landings. Openings between railings shall be
less than 611. Section 1711.
6lc't.) IS
Show how guardrail connection details are
adequate to support 20 pounds per lineal foot at
a right angle to the top rail. Table 23-B.
3 Provide stairway and landing details.
"Section 3306 (b) & (c).
Maximum rise 8" and minimum run is
9".
b. Minimum headroom is 61611.
C. Minimum width is 30".
fl handrails per Section 3306 (j), shall
/satisfy the following:
Provide handrail for stairways with 4
or more risers.
Handrail shall be 30" to 34" above the
nosing of treads.
C. The handgrip portion of handrail shall
be not less than 1 1/4" nor more than
2" in cross-sectional dimension.
(See attached).
Every stairway landing shall have a
"dimension, measured in the direction of travel,
at least equal to the stairway width.
Section 3306 (g).
A door may open over a stairway landing
/Provided the door, in any position, does not
reduce the clear area of the landing in the
direction of stairway travel, to less than
one-half the required width of the stairway.
Section 3306 (g).
A door may open inward at the top step of a
(stairway provided the top step is not more than
7.1/211 lower than the floor level.
Section 3304 (h).
Provide details of winding stairway
(complying with Section 3306 (d):
Minimum tread is 6 inches at any point
and minimum 9 inches at a point 12
inches from where the treads are
narrowest.
Maximum rise is 8 inches.
C. Minimum width is 30 inches.
Provide spiral stairway details, per
(Section 3306 (f):
Minimum run is 7 1/2 inches measured
at a point 12 inches from where the
treads are the narrowest.
Maximum rise is 9 1/2 inches.
C. Minimum headroom is 6 feet 6 inches.
Spiral stairways may not be used for
(required exits when the area served is greater
than 400 sq. ft. Section 3306 (f).
.-cIce7 1'/,jor i,s7 7de,-k /'41
,L.j-.
i Prcv'vT v r, c u et.k. .
TT •
4
3/25/86
Spiral stairways must have a clear walking
space of 26 inches between the column and
handrail, show dimension. Section 3306 (f).
Provide I.C.B.0. Research Report and Number
'for metal stairway, or submit plans and
calculations and approved fabricator registered
with the building department or note that the
stairway fabrication shall be done under special
inspection per the approved fabrication plans.
Section 306 (a) 4B and Section 306 (f).
)I. In buildings over 2 stories in height,
Provide 3/4 hour fire-rated assemblies for all
openings in the exterior wall below or within .10
feet horizontally of an exterior stairway. An
exit balcony with 2 separated stairways is
exempt. Section 3306 (1).
7".
Exterior stairways shall not project into
the 3 foot setback from the property lines.
Section 3306 (n).
The walls and soffits of the enclosed
usable space under interior stairs shall be
protected on the enclosed side as required for
one-hour fire-resistive construction.
Section 3306 (m).
K. ROOFIM
Specify roof slope.
Roof slope is not adequate for roof type
specified. Table 32-B; Section 3203 (h).
Specify roof material and application.
Chapter 32.
Specify I.C.B.0. or U.L. approval number
for roof materials not covered .in U.B.C., e.g.,
title, etc., Section 107.
The maximum slope for a fire retardant
/built-up roof, with rock or gravel surfacing, is
3 inches in 12 inches, Section 3203 (e) 2.
The minimum slope for a fire retardant
built-up roof, with cap sheet surfacing, is 1/2
inch in 12 inches. Section 3203 (e) 3.
Specify minimum 1/4 inch per foot roof /5-
p e for drainage or design to support
accumulated water. Section 3207 (a), Section
2305 (f) and Section 2511 (d) 6.
Show roof drains and overflows.
Section 3207.
Provide skylight details to show compliance
"with Sections 3401 and 5207 or provide I.C.B.0.
approval number.
Plastic skylight must be separated from
(each other by at least 4 feet.
Section 5207 (a) 6.
Show attic ventilation. Minimum vent area
'1s 1/150 of attic area or 1/300 of attic area if
at least 50% of the required vent is at least 3
feet above eave vents or cornice vents. Show
required area and area provided.
Section 3205 (c).
F. MASONRY
Provide fireplace construction details or
note construction to be per attached fireplace
standard drawing. Chapter 37.
oi Show veneer support and connections in
seismic Zones 3 and 4, comply with Section 3002,
4, 5, 6, and Section 2515 (a) regarding ties and
#9 wire in horizontal joints or show
construction to be per attached sheets
30-1 or 30-2.
.i•Z5. Z)Pc..(
5
3/25/86
Show height and construction details of all
/masonry walls. Chapter 24.
Z'. Note that cleanout openings shall be
fprovided at the bottom of all cells to be grout
filled over 4' in a single pour. Cleanout shall
be sealed before grouting, after inspection.
Section 2414 (a) 8.
I. Show floor and roof connections to masonry
'walls. Connection shall resist 200 pounds per
lineal foot or the actual design load, whichever
is greater. Cross grain tension or bending in
wood ledgers is not permitted.
Section 2312 (j) 3. A.
6/ Provide details for damp proofing the
/foundation walls, below finish grade, where
useable space exists on the interior side of the
walls. Section 1707 (d).
Show a minimum 2" air space and flashing
I'between planter and building walls.
Section 2516 (c) 7.
G. GARAGE AND CARPO1S
Z Garage requires one-hour fire protection on
garage side of walls and ceiling common to
the dwelling. Table 5. B. Section 503 (d).
All elements supporting 'floor above garage,
.ncluding walls supporting floor joists, to have
one-hour fire-resistive protection on the garage
side. Section 503 (a).
Z~Show 1 3/8" solid core self-closing door
r openings between garage and dwelling.
Section 503 (d).
/. Openings between carport and residence
trequire self-closing doors and stationary
windows. Section 1214.
Q'r
Show garage framing section, size of header
garage opening, lateral cross bracing at
plate line, method of bracing garage front, and
holddowns if required. Cfiapter 23.
NOTE: Maximum shear panel ratio of height to
width is 3 1/2 to 1. Table 25-I.
Doors may open into the garage only if the
ñoor or landing in the garage is not more than
1/2" lower than the door threshold.
Section 3304 (h).
Provide an 18" raised platform for any FAU,
water heater, or other device in the garage,
which may generate a flame or spark, UMC Section
508, UPC Section 1310 (a).
H. FOUNDATION REDUIREMENTS
'
Per soils report, note on the plan the
soils classification, whether or not the soil is
expansive, and note the allowable bearing value.
Section 2905 (c).
The foundation plan does not comply with
the soil report recommendation for this project.
Please review the report and modify design,
notes and details as required to show
compliance.
Provide notes on the foundation plan
listing the soils report recommendations for
foundations, slab and building pad preparation.
Garages are nât permitted to open into a
room used for sleeping purposes. Section 1104.
'& (1)-4 4u' rcj ovT-
C as Pr Cock. Nr et)-
6
3/25/86
/
7/ The soils report recommends excavations be
reviewed by soils engineer. Note on the
foundation plan that "Prior to the Contractor
requesting a Building Department Foundation
Inspection, the soils engineer shall advise the
building official in writing that:
the building pad was prepared in
accordance with the soils report;
the utility trenches have been
properly backfilled and compacted,
and;
the foundation excavations, formings
and reinforcements comply with the
soils report and approved plan".
Show height of all foundation walls.
chapter 23.
7fr' Show height of retained earth on all
foundation walls. Chapter 23.
o80 If cut or fill slopes exist, show distance
o foundation to edge of cut or fill slopes and
show steepness and heights of cuts and fills.
Chapter 29.
64 lot.-I
Note on plans that wood shall be 6"
(minimum above finish grade.
Section 2516 (c) 7.
9/ Note on plans that surface water will drain
/away from building and show drainage pattern and
key elevations. Section 2905 (f).
9/ Dimension foundation per U.B.C. Table 29A:
Floors
Supported* Stmwall Width Depth
1 6" 12" 12"
2 8" 15" 18"
3 10" 18" 24"
*Foundations may support a roof in addition to
the floors. Where only a roof is supported, use
foundation for one floor.
r0 Co
7
3/25/86'
. Show foundation sills to be pressure.
(treated, or equal. Section 2516 (c) 3.
Show foundation bolt size and spacing.
Section 2907 (e).
X. Specify size, I.C.B.0. number and
manufacturer of power driven pins. Show edge
and end distance and spacing.
Section 306 (f).
11 If required by structural calculations,
show size, imbedment and location of hold down
anchors on foundation plan. Section 2312 (f).
If hold downs are required by calculations,
note on plan that hold down anchors must be tied
in place prior to foundation inspection.
Section 305 (e) 2.
t . Show adequate footings under all bearing
lls and shear walls. Section 2907 (b).
Show on the elevations, stepped footings
for slopes steeper than 1:10.
Section 2907 (c).
Show minimum 18" clearance from grade to
bottom of floor joists and minimum 12"
clearance to bottom of girders.
Section 2516 (c).
() 92 Show pier size, spacing and depth into
undisturbed soil. Table 29-A.
93. Show minimum underfloor access of.8" x
". Section 2516 (c).
S Z e tr
Show minimum underfloor ventilation equal
to 1 sq. ft. for each 150 sq. ft. of underfloor
area. Openings shall be as close to corners as
practicable and shall provide cross ventilation
on at least two approximately opposite sides.
Section 2516 (c).
Specify that posts embedded in concrete
shall be pressure treated per UBC Std. No. 25-
12. Section 2516 (c).
Show wall bracing. Every exterior wood
(stud wall and main cross partition shall be
braced at each end at least every 25 feet of
length with 1 x 4 diagonal let-in braces or
equivalent. Section 2517 (g) 3.
Note cross bridging or blocking. Floor
'joists and rafters 12" or more in depth shall be
supported laterally by bridging at intervals not
exceeding 8 feet, unless both edges are held in
line. Sec. 2506 (g).
8'. Show blocking at ends and at supports of
(floor joists, and for rafters at exterior walls.
Section 2517 (d) 3.
Show solid blocking at ridge line and at
fexterior walls on trussed roofs.
Section 2506 (g), Section 2517 (h).
. Show double joists. Floor joists shall be 0 e
doubled under bearing partitions running
parallel with the joists. Section 2517 (d) 5.
l%' Bearing partitions, perpendicular to
4o15ts, shall not be offset from supporting
girders, beams, walls or partitions, more than
the depth of the joist. Section 2517 (d) 5.
3
P(. Show rafter ties. Rafter ties shall be
spaced not more than 4 feet on center and be
just above the ceiling joists, where rafters and
ceiling joists are not parallel.
Section 2517 (h) 4.
Show rafter purlin braces to be not less
than 45 degrees to the horizontal.
Section 2517 (h) 5.
Show 1/2" minimum clearance between top
fplate of interior partitions and bottom chord of
trusses. (To ensure loading will be as
designed).
Show double top plate with minimum 48"
lap splice Section 2517 (g) 2.
Show nailing will be in compliance with
Table 25-Q.
K Show or note fire stops at the following
ocatifocaons per Section 2516 (f):
in concealed spaces of stud walls and
partitions, including furred spaces,
at the ceiling and floor levels and at
10 foot intervals along the length of
the wall.
at all interconnections between
concealed vertical and horizontal
spaces such as occur at soffits, drop
ceilings and cove ceilings;
C. in concealed spaces between stair
stringers at the top and bottom of the
run and between studs along and in
line with the run of stairs if the
walls under the stairs are unfinished;
and
d. in openings around vents, pipes,
ducts, chimneys, fireplaces and
similar openings which afford a
passage for fire at ceiling and floor
levels, with noncombustible
materials.
Show stud size and spacing. Maximum
allowable stud heights; Bearing wall: 2 x 4 and
2 x 6 max. 10'; Non-bearing: 2 x 4 max. 141 , 2
x 6 max. 201. Table 25-R-3.
Studs supporting two floors, a roof and
ei1ing must be 3 x 40r 2 x 6 a 16" o.c.
Table 25-R-3.
Y- .4o-- r) 1Pcf) 3 ,uLe..e&
1T 4- -4oud . L.!, 6 4r
r 4.lor 'c rT4 rv.
L.4j C&- P
3/25/86
Note an A.I.T.C. Certificate of Compliance
"for glued laminated wood members shall be given
to the building inspector prior to erection.
Section 306 (f).
Detail all post to beam and post to
tooting connections and reference the detail to
the plan. Section 2516 (in).
X. Detail shear transfer connections,
"including roof and floor diaphragms, to shear
walls. Section 2513.
3. Specify nail size and spacing for all
'hear walls, floor and roof diaphragms.
Indicate required blocking. Maintain maximum
diaphragm dimension ratios. (Tables 25 I, 3, K)
and Section 4713 (d).
4 Show 3" x 4" or 2" x 6" studs in first
ory of three story building. Table 25-R-3.
1),' Provide truss details and truss
calculations for this project.
116 Provide roof framing plan and floor
aming plan. Section 302 (a) 7.
Provide framing sections through
Section 320 (a) 7.
R118 Specify all header sizes for opening over
4 wide. Section 2517 (g) 5.
-
l. Provide calculationfor main vertical and
Iorizontal fraiing members and post footings.
Section 302 (a) 7.
l3ø Provide calculations for lateral loads,
ihear panels, shear transfer and related.
Section 302 (9) 7.
7eq
Show on the plans all structural
uirements developed in the structural
calculations.
Columns and posts located on concrete or
('masonry floors or decks exposed to the weather
or to water splash or in basements and which
support permanent structures shall be supported
by concrete piers or metal pedestals projecting
above floors unless approved wood of natural
resistance to decay or treated wood is used.
Section 2516 (c) 4.
'D123 Individual concrete or masonry piers shall
project at least 8 inches above exposed ground
unless the columns or posts which they support
are of approved wood of natural resistance to
decay or treated wood is used.
Section 2516 (c) 4.
r-Or P10.1 5t'X'Po
11( Show location of'attic access with minimum
,'ize 22" x 30". Section 3205.
Show draft separation for attic areas
between units in a duplex. Section 2516 (f).
Wood stud bearing walls, with studs at 24"
o.c., require 3 en. 2 x 4 or 2 ea. 2 x 6 or 2
en. 3 x 4 top plates if supporting either floor
members or roof trusses that are spaced more
than 16" o • c. and do not bear within 5" of the
supporting stud. Section 2517 (g) 2.
13t Specify plywood grade and panel
/identification index. Table 25-N.
When roof pitch is less than 3:12, design
ridge as a beam. Section 2517 (h).
129 If foundation cripple wall studs are less
14" framing shall be solid blocking.
Section 2517 (g) 4.
oc?oT jJL
4 - A)O 16 S if .
Cr " r 4. (I,L, -
'.1
9
3/25/86
139/ Cripple wall studs exceeding 4 feet in
IIig1it shall be 3 inch by 4 inch or 2 inches by
6 inches when supporting 2 stories.,
Section 2517 (g) 4.
el Show plywood sheathing over exposed eaves,
other weather exposed areas, is exterior
grade. Section 2516 (g) 3.
1 . Show a weep screed at the foundation plate
{ine on all exterior and stud walls to be
stuccoed. Section 4706 (e).
/ 1
Show corridor width to be minimum 36".
Section 3305 (b).
Specify truss layout for 30" x 30" attic
access.
Ridges, hips, and valleys shall be at
least one size larger than supported rafters.
Section 2517 (h) 3.
1 6. In open beam construction, provide strap
ties across the beams at the ridge support.
Section 2501 (b).
J. )4ANICAL
All heating, ventilating, and cooling systems
and appliances shall comply with the Uniform
Mechanical Code.
5ting
Show the size, location and type of all
and cooling appliances or systems.
1'1kr
Show source of combustion air to furnace,
per Chapter 6, UMC.
139 Every dwelling unit shall be provided with
heating facilities capable of maintaining a room
temperature of 70 degrees F. at 3 feet above the
floor in all habitable rooms. Show basis for
compliance. UBC, Section 1211.
10
3/25/86
l)4" Show minimum 30" deep unobstructed working
cpace in front of furnace. Section 505, UMC.
Note on plans, clearances to be per
manufacturer's listing. Section 504, UMC.
/s Furnace shall not be installed under any
tairway. Section 704, UMC.
~room,
Furnace shall not be installed in any
bathroom or in a closet or confined
space with access only through such room, unless
specified as direct vent appliance, enclosed
furnace or electric heating appliance.
Section 704, UMC.
G
144 Show I.C.B.0. approval number for prefab
ireplace.
LJetiii. lc-6o nu ' j Usc. 'P1"ro-€J S 145 Show access to the attic or underfloor
ce to be minimum 30 inches by 30 inc.
Section 708 & 709 UMC.
lt Note that passageway to the attic furnace
hall be unobstructed and have continuous solid
flooring not less than 24 inches wide.
Section 708, UMC.
13v1 Show permanent electrical outlet and
lighting fixture controlled by a switch for the
attic furnace. Section 708, UMC.
lJI Show details to comply with Section 709
or furnace under the floor, or Section 710 for
roof or outside furnace.
Note on plan: Gas vents and
noncombustible piping passing through three
floors or less shall be effectively draft
stopped at each floor or ceiling.
UBC, Section 1706 (a) 6.
K. EI.ICAL (NATIONAL ELICAL a,OE)
All wiring shall comply with the National
Electrical Code.
150 Show on the plan the amperage of the
e ctrical service, thelocation of the service
panel and the location of any sub-panels.
SoP.JC,Tb 7L0X
Show location of all electrical.
receptacles.
Electrical receptacle locations and/or
spacing is not adequate in
l/ Show at least one convenience outlet other
than outlets for laundry, etc., outdoors, in
garages and basments. NEC, Art. 210-52.
l5 Note convenience outlets in bathrooms,
doors, and in garages and basements (other
than for laundry and similar equipment) shall be
GFI protected, NEC, Art. 210-8.
15$ Note electrical system ground to be
pfovided per NEC, Art. 250-81.
L. PLUMBING (UNIFORM PLUMBING ()DE)
Show water heater size, type and location
n plans. UPC, Section 1310.
I.W. Show source for providing combustion air
o fuel burning water heater. If wall opening
in an enclosure are used, at least one-half of
the required opening area shall extend into the
upper twelve inches of the enclosure and
one-half within the lower twelve inches.
UPC, Section 1307.
11
3/25/86
1 '. Fuel combustion water heater shall not be
f'nstalled in bath or bedroom or in a closet
opening into bath or bedroom.
UPC, Section 1309.
Z. Provide adequate barrier to protect water
ter from vehicle damage. UPC, Section 1310.
1)6. Show T and P Valve on water heater and
how route of discharge line to exterior.
UPC, Section 1007 (e).
z Provide dryer vent to outside.
C, Section 1903.
Note on the plan that hose bibbs and lawn
fsprinkler systems shall have approved backf low
prevention devices. UPC, Section 1003.
193' Shower stall shall accommodate a 30"
c!ircle and have a minimum floor area of
1,024 sq. in. UPC, 909 (d).
M. NOISE INSULATION (DUPLEX)
l)2( Show details of duplex common (party)
a1ls and floor/ceiling assemblies to achieve a
Sound Transmission Class (SIC) rating in walls
of 50 decibles and on Impact Insulation Class
(IIC) rating on floor/ceiling of 50 decibles.
Title 25.
?ip~g,
Show how penetrations of assemblies for
electrical devices, recessed cabinets,
bathtubs, soffits, or heating ventilating, or
exhaust ducts shall be sealed, lined, or
insulated to maintain required sound
transmission rating. Title 25.
ipi. Provide insulation in walls and ceiling to
achieve SIC of 50 between garage and living area
if garage use is not controlled by resident.
Title 25.
N. KNY cONSKRVAT1ON: PLEASE READ
State regulations (California Admin. Code)
require that the design satisy one of the
attached alternative energy packages or submit
calculations. The law also requires that many
mandatory conservation items be satisfied..
Qu
Show on the Title Sheet of the lans the
ired elements of the alternative energy
package that was selected, and next to each
element show how you are cqpplyjpg wiih path-
element. If calculations were used, provide
similar data on the plans.
16)? The plan sheet showing the required
/ ements of the selected energy package, and
listing the design elements showing compliance
with that selected package, must be signed by
either the owner or a licensed professional
i.e., architect, engineer or contractor. A
design professional must note his/her state
license number. Section 1403 of Title 20.
16)? Show on the plans the "R" value for the
/ails, floors,, ceiling and related areas.
Show double glazing as per Energy Design,
'n Glazing Schedule.
6) Show on the plan how shading requirements
are satisfied.
The plans are not in compliance with the
energy conservation compliance package selected
or design calculations provided. Show on plans
conformance as follows:
12
3/25/86
() Specify on the building plans all of the
mandatory energy conservation requirements as
listed on the enclosure titled, "Mandatory
Energy Conservation Requirements".
Show the size, type, make, model and
"location of the space heating (or cooling)
system and provide heat loss calculations if the
output BTU/Hr. exceeds 45,000.
0. CARLSBAD S.F.D. & DUPLEX SUPPLEMEMr
0~5 Energy conservation design should be for
Zone 7 . See attached energy packages.
1706 Floor drains must have auto-prime
(city policy).
Note exhaust fans cannot be ductless type
(city policy).
New residential units must be pre-plumbed
or future solar water heating. Note "two roof
jacks must be installed" where the water heater
is in the one story garage and directly below
the most south facing roof
(City Ordinance No. 8093).
,
y4'. Note "two 3/4" copper pipes must be
installed to the most convenient future solar
panel location when the water heater is not in a
one story garage and is not directly below the
most south facing roof.
(City Ordinance No. 8093).
W. All piping for present or future solar
water heating must be insulated when in areas
that are not heated or cooled by mechanical
means (city policy).
Incorporate the waterproofing details, on
he attached Policy 80-8, where interior living
space occurs below grade at the masonry
wall(s).
Show on the Title Sheet on the plans, the
information required by the attached
Developmental Services Sheet 102683.
Qi
All new residential buildings, including
tions, require a soils report. Please
submit two copies.
SAP— oPPoS,
Heavy timber framing, minimum 6" x 10"
6eams and minimum 8" x 8" post, for the
structural beam and column supporting the fire
separation between the garage and living area
above, is acceptable if shown on the plans.
(city policy).
4 Please see additional corrections, or
.emarks, on the following page.
The City of Carlsbad has contracted with Esgil
Corporation located at 9320 chesapeake Drive,
Suite 208, San Diego, California 92123;
telephone number of 619/560-1468, to perform the
plan check for your project. If you have any
questions regarding these plan check items,
please contact ' A.bi.
at Esgil Corporation. If you have any questions
regarding City Building permit procedures,
please contact Carter Darnell at the City of
Carlsbad, 1200 Elm Avenue,
telephone 619/438-5525.
Thank you.
Enclosures:
13
3/25/86
oJ
(U-"W-(. c,vr T
'-U-- re ,T1L
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE: 7\k)\\ DAPPLICANT
URISDICT
JURISDICTION: CITY OF CARLSBAD ' CHECKER
- FILE COPY
PLAN CHECK NO: ,S7(L2- T [3 UPS
[]DESIGNER
PROJECT ADDRESS:
PROJECT NAME:
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
E with the jurisdiction's building codes when minor deficien-
cies identified are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
Fl identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is the jurisdiction's
copy for your information. The plans are being held at
Esgil Corp. until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy 'of the check list has been sent to:
CLLE -
Esgil staff did not advise the applicant contact person that
plan check ha 's been completed.
Esgil staff did advise applicant that the plan check has
been completed. Person contacted: Mr. h-r IVTTEMPTI -
' ')A NS 1J 7L
Date contacted: 'i-. Telephone #1D_cPr?O
REMARKS:
BY: •5/c:c'15
ESGIL CORPORATION
ENCL:
PLAN cEcKNQ. (O
JURISDICTION: CITY OF CARLSBAD
TO: Mr. C)()c\
I /4 r Is
TELKPHDNEno.
RELOSUR: pare
Ls
PJ ADDRESS: CoR.
PLAN Q)RRECflON SHEKt
SI!K FAMILY AND DUPLEX ThJELLIWS
Date plans received by jurisdiction:
-7 la
Date plans received by Esgil Corporation:
Date initial plan check completed:
By:_________________
Applicant contact person:
Telephone: 3-YrSO
FOREWORD: PLEASE READ
Plan check is limited to technical requirements
contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code,
National Electrical Code and state laws
regulating energy conservation, noise
attenuation and access for the handicapped.
The plan check is based on regulations enforced
by the Building Inspection Department. You may
have other corrections based on laws and
ordinances enforced by the Planning Department,
Engineering Department or other departments.
Present California law mandates that
residential construction cothply with Title 24
and the following model codes:
1982 UBC (eff. 7/1/85)
1982 UPC (eff. 10/1/85)
1984 NEC (eff. 10/1/85)
1982 UMC (eff. 3/1/85)
The above regulations apply to residential
construction, regardless of the code editions
adopted by ordinance.
The circled items need clarification,
modification or change. All items have to be
satisfied before the plans will be in
conformance with the cited codes and
regulations. Per Sec. 303 (c), 1982 Uniform
Building Code, the approval of the plans does
not permit the violation of any state, county
or city law.
7 To speed up the recheck process, note on this
list (or a copy) where each correction item has
been addressed i.e.. plan sheet, specification.
etc. Be sure to enclose the marked up list
when you submit the revised plans.
Carlsbad List 10, Single Family Dwelling and Duplex With All Supplements
1
3/25/86
A. PLANS
1. Please make all corrections on the original
racings and submit two new sets of prints, and
any original plan sets that may have been
returned to you by the jurisdiction, to:
Esgil Corporation, 9320 Chesapeake Drive,
Suite k208, San Diego, California 92123,
(619) 560-1468.
/ Please make all corrections on the original
tracings and submit two new sets of prints, and
any original plan sets that may have been
returned to you by the jurisdiction, to:
The jurisdiction's building department.
/the
Indicate on the Title Sheet of the plans,
name of the legal owner and name of person
responsible for the preparation of the plans.
Section 302 (a) 7.
Plans, specifications and calculations shall
be signed by a California state licensed
engineer or architect. (California Business and
Professions Code).
5. Specify on the Title Sheet of the plans the
ross floor area of each element of this project
including dwelling, garage, carport, patio, deck
aqO ba1ony. Section 302 (c).
__4__\_y)
Qe
Provide a statement on the Title Sheet of
plans that this project shall comply with
Title 24 and 1982 TJBC, IJMC, and UPC and 1984
NEC.
Submit fully dimensioned plot plan drawn to
scale showing location, size, and use of all
existing and proposed structures on the lot.
Identify property lines and show lot dimensions
and all easements. Show location of all cut or
fill slopes and approximate finish floor
elevations for all structures and show
elevations at all lot corners.
Section 302 (c).
,W' Indicate distance from center line of street
or alley to property line and distance from
property lines to proposed building.
Section 302 (c).
B.
IV Walls closer than 3 feet to property lines
shall be one-hour rated construction, have no
openings, and shall have 30 inch parapets when
the building floor area exceeds 1,000 square
feet on any floor.
(Table 5. A. Section 1709 (a)).
p< Projections, including eaves, may not
extend more than 12 inches into the 3 foot
setback from the property line. Eaves over
required windows shall be not less than 30
inches from the side and rear property lines.
Section 1710 and Section 504 (a) and (b).
t'i Plastic skylights shall not be installed
within 8' of an exterior wall located where
openings in such exterior wall are prohibited or
required to be protected.
Section 5207 (a) 7.
32'. Projections, including eaves, shall be
one-hour fire-resistive construction, heavy
timber or of noncombustible material if they
project into the 3' setback area from the
property line. Section 1710.
Show location of permanently wired smoke
detector, centrally located in corridor leading
to sleeping rooms or above stair if sleeping
rooms are on upper level. Section 1210.
A smoke detector shall be installed in the
basement of dwelling units having a stairway
which opens from the basement into the dwelling.
Such detector shall be connected to a sounding
device or other detector to provide an alarm
which will be audible in the sleeping area.
Section 1210.
0 PôrT Tt,L Pk
2
3/25/86
C. ROCK SIZES. LI . VENflLAIION AND GLAZING
Habitable rooms, other than kitchens, shall
contain at least 70 square feet of floor area.
Section 1207 (b).
Window area must be at least 1/10 of the
floor area and a minimum of 10 square feet per
Section 1205 (a). Appears to be deficient in
I) Openable window area in habitable rooms
must be 1/20 of the floor, area and a minimum of
5 square feet. In bathrooms, laundry rooms and
similar rooms 1/20 of area is required' and
minimum is 1.5 sq. ft. (Section 1205 (a)).
,C,r
At least 1/2 of the common wall, must be
open and have an opening not less than 25 sq.
ft. if light and ventilation is being supplied
from an adjacent room. Section 1205 (a).
J
Required windows shall not openinto a
roofed'porch,unless the ceiling is at least 7
feet and the longer side is at least 65% open.
Section 1205 (a).
Provid mechanical ventilation capable of
providing five air changes per, hour in
bathrooms, water closet compartments, laundry
rooms and similar rooms if required opnable
windows are not provided. Section 1205 (a).
No habitable room, other than a kitchen,
shall be lss than 71 011 in any dimension.
Section 1207 (c).
3,2< Show that ceiling height for habitable
rooms is a minimum of 716". Section 1207 (a).
Show ceiling height for laundry rooms,
hallways, corridors, and bathrooms is a minimum
of 710". Section 1207 (a).
Y4< Dimension on the plans, the 30" clear width
for water closet compartments and 24" clearance
in front of water closet.
Section 511 (a).
39. Specify safety glazing for glazing in
hazardous locations such as glass doors, glazing
adjacent to such doors and glazing adjacent to
walking surfaces. Section 5406.
Glazing, in the same wall plane as a door,
must be safety glazing if within 12" of the door
and less than 60" above the walking surface,
unless the glazing is leaded on faceted glass.
Section 5406 (d) 7.
Glazing in shower and tub enclosures shall
be tempered, laminated or approved plastic
(including windows within 5 feet of tub or
shower floor). Section 5406 (d) 5.
Sleeping rooms shall have a window or
exterior door for emergency exit. Sill height
shall not exceed 44" above the floor. The
window must have an openable area of at least
5.7 square feet with the minimum openable width
20" and the minimum openable height 24".
Section 1204.
391 A mezzanine is an intermediate floor and
may not have a floor area exceeding 33 1/3
percent of the total floor area in the room
below. The mezzanine floor must have a clear
height of 7 feet, above and below, and must have
the long side open to the room below except for
posts and protective walls or railings not
exceeding 42" in height. Section 1716.
34'. The loft you show does not comply as a
mezzanine floor and is, by Uniform Building Code
definition, a story. Section 1716.
D. KKITS, STAIRWAYS, AND RAILINGS /. Every stairway landing shall have a
dimension, measured in the direction of travel,
Floors above the second story shall.have at least equal to the stairway width.
not less than 2 exits. Section 3303 (a). Section 3306 (g).
ly Required exit doorways shall be not less )1. A door may open over a stairway landing
than 36" in width and not less than 6'8" in provided the door, in any position, does not height, and shall be capable of opening at least reduce the clear area of the landing in the
90 degrees. Section 3304 (e). direction of stairway travel, to less than
one-half the required width of the stairway.
Provide 36" high protective railing for
~Les,
Section 3306 (g).
balconies, and open sides of stair
landings. Openings between railings shall be A door may open inward at the top step of a less than 611 . Section 1711.
Pro,j.d& diTa ,1_ck.(.6e!ou7')1121, stairway provided the top step is not more than
'JLn lower than the floor level.
34. Show how guardrail connection details are Section 3304 (h).
equate to support 20 pounds per lineal foot at
a right angle to the top rail. Table 23-B. 71. Provide details of winding stairway
,o'zT deck i-- complying with Section 3306 (d):
Provide stairway and landing details.
Section 3306 (b) & (c). a. Minimum tread is 6 inches at any point
Maximum rise 8" and minimum run is
9".
Minimum headroom is 6161t.
C. Minimum width is 30".
36'. All, handrails per Section 3306 (j), shall
satisfy the following:
Provide handrail for stairways with 4
or more risers.
Handrail shall be 30" to 34" above the
nosing of treads.
C. The handgrip portion of handrail shall
be not less than 1 1/4" nor more than
2" in cross-sectional dimension.
(See attached).
and minimum 9 inches at a point 12
inches from where the treads are
narrowest.
b. Maximum rise is 8 inches.
C. Minimum width is 30 inches.
50. Provide spiral stairway details, per
Section 3306 (f):
Minimum run is 7 1/2 inches measured
at a point 12 inches from where the
treads are the narrowest.
Maximum rise is 9 1/2 inches.
C. Minimum headroom is 6 feet 6 inches.
4'. Spiral stairways may not be used for
required exits when the area served is greater
than 400 sq. ft. Section 3306 (f).
}J L( PIT 4rr Pv rt ric deTk 1c
cIek QciclCT T r-r )-/p to
4
3/25/86
Spiral stairways must have a clear walking
space of 26 inches between the column and
hthidrail, show dimension. Section 3306 (f).
Provide I.C.B.O. Research Report and Number
for metal stairway, or submit plans and
calculations and approved fabricator registered
with the building department or note that the
stairway fabrication shall be done under special
inspection per the approved fabrication plans.
Section 306 (a) 4B and Section 306 (f).
In buildings over 2 stories in height,
Provide 3/4 hour fire-rated assemblies for all
openings in the exterior wall below or within 10
feet horizontally of an exterior stairway. An
exit balcony with 2 separated stairways is
exempt. Section 3306 (1).
Exterior stairways shall not project into
the 3 foot setback from the property lines.
Section 3306 (n).
The walls and soffits of the enclosed
usable space under interior stairs shall be
protected on the enclosed side as required for
one-hour fire-resistive construction.
Section 3306 (m).
K. ROOFIM
9 Specify roof slope.
49. Roof slope is not adequate for roof'type
specified. Table 32-B; Section 3203 (h).
() Specify roof material and application.
Chapter 32.
Specify I.C.B.0. or U.L.-approval number
for roof materials not covered in U.B.C., e.g.,
title, etc., Section 107.
5
3/25/86
The maximum slope for a fire retardant
built-up roof, with rock or gravel surfacing, is
3 inches in 12 inches, Section 3203 (e) 2.
53 The minimum slope for a fire retardant
uilt-up roof, with cap sheet surfacing, is 1/2
inch in 12 inches. Section 3203 (e) 3.
Specify minimum 1/4 inch per foot roof
slope for drainage or design to support
accumulated water. Section 3207 (a), Section
2305 (f) and Section 2511 (d) 6.
Show roof drains and overflows.
Section 3207.
56. Provide skylight details to show compliance
ith Sections 3401 and 5207 or provide I.C.B.0.
approval number.
A
Plastic skylight must be separated from
each other by at least 4 feet.
Section 5207 (a) 6.
(,) Show attic ventilation. Minimum vent area
s 1/150 of attic area or 1/300 of attic area if
at least 50% of the required vent is at least 3
feet above eave vents or cornice vents. Show
required area and area provided.
Section 3205 (c).
F. MASONRY
059- Provide fireplace construction details or
note construction to be per attached fireplace
standard drawing. Chapter 37.
Show veneer support and connections in
Seismic Zones 3 and 4, comply with Section 3002,
4, 5, 6, and Section 2515 (a) regarding ties and
#9 wire in horizontal joints or show
construction to be per attached sheets
30-1 or 30-2.
Show height and construction details of all
masonry walls. Chapter 24.
Note that cleanout openings shall be
provided at the bottom of all cells to be grout
filled over 4' in a single pour. Cleanout shall
be sealed before grouting, after inspection.
Section 2414 (a) 8.
Show floor and roof connections to masonry
walls. Connection shall resist 200 pounds per
lineal foot or the actual design load, whichever
is greater. Cross grain tension or bending in
wood ledgers is not permitted.
Section 2312 (j) 3. A.
Provide details for damp proofing the
foundation walls, below finish grade, where
useable space exists on the interior side of the
walls. Section 1707 (a).
Show a min41 imum 2" air space and flashing
between planter and building walls.
Section 2516 (c) 7.
G. GARAGE AND CARPORTS
96 Garage requires one-hour fire protection on
the garage side of walls and ceiling common to
the dwelling. Table S. B. Section 503 (d).-
,0,7. All elements supporting floor above garage,
including walls supporting floor joists, to have
one-hour fire-resistive protection on the garage
side. Section 503 (a).
Show 1 3/8" solid core self-closing door
f or openings between garage and dwelling.
Section 503 (d).
Openings between carport and residence
require self-closing doors and stationary
windows. Section 1214.
71. Show garage framing section, size of header
er garage opening, lateral cross bracing at
plate line, method of bracing garage front, and
holddowns if required. Chapter 23.
:5eQ
NOTE: Maximum shear panel ratio of height to
width is 3 1/2 to 1. Table 25-I.
Doors may open into the garage only if the
floor or landing in the garage is not more than
1/2" lower than the door threshold.
Section 3304 (h).
Provide an 18" raised platform for any FAU,
water heater, or other device in the garage,
which may generate a flame or spark, UNC Section
508, UPC Section 1310 (a).
H. FOUNDATION Rju1101E0M
() Per soils report, note.on the plan the
soils classification, whether or not the soil is
expansive, and note the allowable bearing value.
Section 2905 (c).
The foundation plan does not comply with
e soil report recommendation for this project.
Please review the report and modify design,
notes and details as required to show
compliance.
Provide notes on the foundation plan
'sting the soils report recommendations for
foundations, slab and building pad preparation.
.5 L '3 OJL
Garages are not permitted to open into a
room used for sleeping purposes. Section 1104.
6
3/25/86
3)7< The soils report recommends excavations be
reviewed by soils engineer. Note on the
foundation plan that "Prior to the Contractor
requesting a Building Department Foundation
Inspection, the soils engineer shall advise the
building official in writing that:
1. the building pad was prepared in
accordance with the soils report;
Show foundation sills to be pressure
treated, or equal. Section 2516 (c) 3.
Show foundation bolt size and spacing.
Section 2907 (e).
Specify. size, I.C.B.0. number and
manufacturer of power driven pins. Show edge
and end distance and spacing.
Section 306 (f).
If required by structural calculations,
show size, imbedment and location of hold down
anchors on foundation plan. Section 2312 (f).
3. the foundation excavations, formings
and reinforcements comply with the 8,g' If hold downs are required by calculations,
soils report and approved plan". note on plan that hold down anchors must be tied
in place prior to foundation inspection.
~pter
Show height of all foundation walls. Section 305 (e) 2.
23.
t89) Show adequate footings under all bearing
Shbw height of retained earth on all walls and shea walls. Section 2907 (b).
foundatiàn walls. Chapter 23.
Show on the elevations, stepped footings
If cut or fill slopes exist, show distance for slopes steeper than 1:10.
o foundation to edge of cut or fill slopes and Section 2907 (c).
show steepness and heights of cuts and fills.
Chapter 29. 91. Show minimum 18" clearance from grade to J T c:- P'ottom of floor joists and minimum 12
Note on plans thae wood shall be.6" clearance to bottom of girders.
minimum above'finish grade. Section 2516 (c). Section 2516 (c) 7.
/ () Show pier size, spacing and depth into /1. Note on plans that surface water will drain undisturbed soil. Table 29-A. away from building and show drainage pattern and
key elevations. Section 2905 (f). 93. Show minimum underfloor access of 18" x
". Section 2516 (c).
Dimension foundation per U.B.C. Table 29A:
Floors
Supported* Stemwall Width Depth
1 6" 12" 12"
2 8" 15" 18"
3 10" 18" 24"
Foundations may support ',a roof in addition to
the floors. Where only a roof is supported, use
foundation for one floor.
___. cp •t') k \ 'er
rdL StZe 5 Z ST.
7
3/25/86
2. the utility trenches have been
properly backfilled and compacted,
and;
() Show minimum underfloor ventilation equal
to 1 sq. ft. for each 150 sq. ft. of underfloor
area. Openings shall be as close to corners as
practicable and shall provide cross ventilation
on at least two approximately opposite sides.
Section 2516 (c).
Specify that posts embedded in concrete
shall.be pressure treated per UBC Std. No. 25-
12. Section 2516 (c).
I. FR.AHI*
Show wall bracing. Every exterior wood
stud wall and main cross partition shall be
braced at each end at least every 25 feet of
length with 1 x 4 diagonal let-in braces or
equivalent. Section 2517 (g) 3.
71' Note cross bridging or blocking. Floor
joists and rafters 12" or more in depth shall be
supported laterally by bridging at intervals not
exceeding 8 feet, unless both edges are held in
line. Sec. 2506 (g).
Lo_O 98. Show blocking at ends and at supports of
oor joists, and for rafters at exterior walls.
Section 2517 (d) 3.
99 Show solid blocking at ridge line and at
exterior walls on trussed roofs.
Section 2506 (g), Section 2517 (h).
CtI _2_-2 T1?2 PF Show double joistcs. FlFjIts shall be
doubled under bearing partitions running
parallel with the joists. Section 2517 (d) 5.
(). Bearing partitions, perpendicular to
joists, shall not be offset from supporting
girders, beams, walls or partitions, more than
the depth of the joist. Section 2517 (d) 5.
22. Show rafter ties. Rafter ties shall be
spaced not more than 4 feet on center and be
just above the ceiling joists, where rafters and
ceiling joists are not parallel.'
Section 2517 (h) 4.
1,011( Show rafter purlin braces to be not less
than 45 degrees to the horizontal.
Section 2517 (h) 5.
39I. Studs supporting two floors, a roof and
ceiling must be 3 x 4 or 2 x 6 at 16" o.c.
Table 25-R-3.
104 Show 1/2" minimum clearance between top
p ate of interior partitions and bottom chord of
trusses. (To ensure loading will be as
designed).
ip. Show double top plate with minimum 48"
'sap splice. Section 2517 (g) 2.
Show nailing will be in compliance with
able 25-Q.
ec
Show or note fire stops at the following
ons per Section 2516 (f):
a.' in concealed spaces of stud walls and
partitions, including furred spaces,
at the ceiling and floor levels and at
10 foot intervals along the length of
the wall.
b. at all interconnections between
concealed vertical and horizontal
spaces such as occur at soffits, drop
ceilings and cove ceilings;
C. in concealed spaces between stair
stringers at the top and bottom of the
run and between studs along and in
line with the run of stairs if the
walls under the stairs are unfinished;
and
d. in openings around vents, pipes,
ducts, chimneys, fireplaces and
similar openings which afford a
passage for fire at ceiling and floor
levels, with noncombustible
materials.
E108 Show stud size and spacing. Maximum
a owable stud heights; Bearing wall: 2 x 4 and
2 x 6 max. 101 ; Non-bearing: 2 x 4 max. 141, 2
x 6 max. 201. Table 25-R-3.
8-
3/25/86
Note an A.I.T.C. Certificate of Compliance
for glued laiinated wood members shall be given
to the building inspector prior to erection.
Section 306 (f).
1).?. Show on the plans all structural
requirements developed in the structural
calculations.
111 Detail all post to,beam and post to
footing connections and reference the detail to
the plan. Section 2516,(m).
ro,,7-
1121 Detail shear transfer connections,
including roof and floor diaphragms, to shear
walls., Section 2513.
fJL
~12~i
'Specify nail size and'spacing for all
walls, floor and roof diaphragms.
Indicate required blocking. Maintain' maximum
diaphran dimension ratios. (Tables 25 I, J, K)
and Section 4713 (d).
Show 3" x 4" or 2" x 6" studs in first
story of three story building. Table 25-R-3.
Show draft separation for attic areas
between units in a duplex. Section 2516 (f).
116. Provide roof framing plan and floor
in plan. Section 302 (a) 7. , 32'. Wood stud bearing walls, with studs at 24"
:;tr 'ta'cX tor,pLrai 4orô'ko.c., require 3 ea. 2 x 4 or 2 ea. 2 x 6 or 2
117'. '?rovide framing sections through en. 3 x 4 top plates if supporting either floor
members or roof trusses that are spaced more
'OV\AP Cepp\,T. ull than 16" o.c. and do not bear within 5" of the
supporting stud. Section 2517 (g) 2.
IYIj , - PrQ
Section 320 (a) 7.
ac
Provide truss details and truss
ulations for this project.
i1. Columns and posts located on concrete or
6iasonry floors or decks exposed to the weather
or to water splash or in basements and which
support permanent structures shall be supported
by concrete piers or metal pedestals projecting
above floors unless approved wood of natural
resistance to decay or treated wood is used.
Section 2516 (c) 4.
0123., Individual concrete or masonry piers shall
project at least 8 inches above exposed ground
unless the columns or posts which they support
are of approved wood of natural resistance to
decay or treated wood is used.
Section 2516 (c) 4.
Show location of attic access with minimum
size 22" x 30". Section 3205.
127 Specify plywood grade and panel
i entification index. Table 25-N.
Specify all header sizes for opening over 118
wide. Section 2517 (g) 5.
Provide calculations for main vertical and
horizontal framing members and post footings.
Section 302 (a)'7.
9I. When roof pitch is less than 3:12, design
ridge as a beam. Section 2517 (h).
9. If foundation cripple wall studs are less
than 14" framing shall be solid blocking.
Section 2517 (g) 4.
Provide calculations for lateral loads,
shear panels, shear transfer and related.
Section 302 (9) 7.
'
44 o ropl C.lI , LI -
O)S5 4'IC. .
•
#
•
9
3/25/86
e Cripple wall studs exceeding 4 feet in
ght shall be 3 inch by 4 inch or 2 inches by
6 inches when supporting 2 stories.
Section 2517 (g) 4.
i1'. Show plywood sheathing over exposed eaves,
or other weather exposed areas, is exterior
grade. Section 2516 (g) 3.
132 Show a wep screed at the foundation plate
e on all exterior and stud walls to be
stuccoed. Section 4706 (e).
Show corridor width to be minimum 36".
Section 3305 (b).
0134- Specify truss layout for 301"x 30" attic
access.
Ridges, hips, and valleys shall be at
least one size larger than supported rafters
Section 2517 (h) 3.
Pb". In open beam construction, provide strap
ties across the beams at the ridge support.
Section 2501 (b).
J. MECHANICAL
All heating, ventilating, and cooling systems
and appliances shall comply with the Uniform
Mechanical Code.
€E) Show the size, location and type of all
heating and cooling appliances or systems.
9'. Show source of combustion air to furnace,
per Chapter 6, UMC.
139 Every dwelling unit shall be provided with
h ting facilities capable of maintaining a room
temperature of 70 degrees F. at 3 feet above the
floor in all habitable rooms. Show basis for
compliance. UBC, Section 1211.
10
3/25/86
Show minimum 30" deep unobstructed working
space in front of furnace. Section 505, UMC.
Note on plans, clearances to be per
nufacturer's listing. Section 504, UMC.
Furnace shall not be installed under any
stairway. Section 704, UMC.
143 Furnace shall not be installed irf any
bedroom, bathroom or in a closet or confined
space with access only through such room, unless
specified as direct vent appliance, enclosed
furnace or electric heating appliance.
Section 704, UMC.
144. Show I.C.B.0. approval number for prefab
ireplace.
(l ' Show access to the attic or underfloor
iinace to be minimum 30 inches by 30 inches.
Section 708 & 709 UMC.
passageway to the attic furnace
sháil be unobstructed and have continuous solid
flooring not less than 24 inches wide.
Section 708, UMC.
(l47 Show permanent electrical outlet and
'ttiting fixture controlled by a switch for the
attic furnace. Section 708, UMC.
pp/' (r i1e
1)8' Show details to comply with Section 709
for furnace under the floor, or Section 710 for
roof or outside furnace.
Note on plan: Gas vents and
noncombustible piping passing through three
floors or less shall be effectively draft
stopped at each floor or ceiling.
UBC, Section 1706 (a) 6.
ELICAL (NATIONAL ELEMICAL (Th)E)
All wi?ing shall comply with the National
Electrical Code.
2150 Show on the plan the amperage of the
e ectrical service, the location of the service
panel and the location of any sub-panels.
Show location of all electrical
receptacles.
35I. Electrical receptacle locations and/or
spacing is not adequate in
11 Show at least one convenience outlet other
than outlets for laundry, etc., outdoors, in
garages and basements. NEC, Art. 210-52.
154 Note convenience outlets in bathrooms,
ou doors, and in garages and basements (other
than for laundry and similar equipment) shall be
GFI protected, NEC, Art. 210-8.
l,5fg. Note electrical system ground to be
provided per NEC, Art. 250-81.
PUfl4B]B (UNIFo1l PLUMBING 0)0K)
ifi. Show water heater size, type and location
on plans. UPC, Section 1310.
Show source for providing combustion air
to fuel burning water heater. If wall opening
in an enclosure are used, at least one-half of
the required opening area shall extend into the
upper twelve inches of the enclosure and-
one-half within the lower twelve inches.
UPC, Section 1307.
Fuel combustion water heater shall not be
installed in bath or bedroom or in a closet
opening into bath or bedroom.
UPC, Section 1309.
3.54. Provide adequate barrier to protect water
heater from vehicle damage. UPC, Section 1310.
l, Show T and P Valve on water heater and
show route of discharge line to exterior.
UPC, Section 1007 (e).
9. Provide dryer vent to outside.
UMC, Section 1903.
C162~ Note on the plan that hose bibbs and lawn
sprinkler systems shall have approved backf low
prevention devices. UPC, Section 1003.
lfr ' Shower stall shall accommodate a 30"
circle and have a minimum floor area of
1,024 sq. in. UPC, 909 (d).
NOISE INSULATION (1)0PLEXES)
Show details of duplex common (party)
walls and floor/ceiling assemblies to achieve a
Sound Transmission Class (SIC) rating in walls
of 50 decibles and on Impact Insulation Class
(IIC) rating on floor/ceiling of 50 decibles.
Title 25.
lftrI. Show how penetrations of assemblies for
piping, electrical devices, recessed cabinets,
bathtubs, soffits, or heating ventilating, or
exhaust ducts shall be sealed, lined, or
insulated to maintain required sound
transmission rating. Title 25.
ipli Provide insulation in walls and ceiling to
achieve SIC of 50 between garage and living area
if garage use is not controlled by resident.
Title 25.
(/5_Ct,\ E k(Trc
11
3/25/86
N. ENT CONSERVATION: PLEASE READ
State regulations (California Admin. Code)
require that the design satisy one of the
attached alternative energy packages or submit
calculations. The law also requires that many
mandatory conservation items be satisfied.
() Show on the Title Sheet of the plans, the
required elements of the alternative energy
package that was selected, and next to each
element show how you are complying with each
element. If calculations were used, provide
similar data on the plans.
The plan sheet showing the required
elements of the selected energy package, and
listing the design elements showing compliance
with that selected package, must be signed by
either the owner or a licensed professional
i.e., architect, engineer or contractor. A
design professional must note his/her' state
'license number. Section 1403 of Title 20.
Show on the plans the "R" value for the
walls, floors, ceiling and related areas.
Show double glazing as per Energy Design,
'OeGlazing Schedule.
el7l) Show on the plan how shading requirements
are satisfied.
1 . The plans are not in compliance with the
energy conservation compliance package selected
or design calculations provided. Show on plans
conformance as follows:
G73. Specify on the building plans all of the
mandatory energy conservation requirements as
listed on the enclosure titled, "Mandatory
Energy Conservation Requirements".
Zc
Show the size, type, make, model and
ation of the space heating (or cooling)
system and provide heat loss calculations if the
output BTU/Hr. exceeds 45,000.
0. CARLSBAD S.F.D. & IXJPLRE SUPPLT
(175. Energy conservation design should be for
Z5ne 7 . See attached energy packages.
(im) Floor drains must have auto-prime
Elty policy).
(1) Note exhaust fans cannot be ductless type
(—City policy).
Q017
,
8).New residential units must be pre-plumbed
future solar water heating. Note "two roof
jacks must be installed" where the water heater
is in the one story garage and directly below
the most south facing roof
(City Ordinance No. 8093).
Y Note "two 3/4" copper pipes must be
stalled to the most convenient future solar
panel location when the water heater is not in a
one story garage and is not directly below the
most south facing roof.
(City Ordinance No. 8093).
() All piping for present or future solar
water heating must be insulated when in areas
that are not heated or cooled by mechanical
means (city policy).
Incorporate the waterproofing details, on
the attached Policy 80-8, where interior living
space occurs below grade at the masonry
wall(s).
12
3/25/86
3r Show on the Title Sheet on the plans, the
information required by the attached
Developmental Services Sheet 102683.
ad
All new residential buildings, including
itions, require a soils report. Please
submit two copies. i - -
ip. Heavy timber framing, minimum 6" x 10"
teams and minimum 8" x 8" post, for the
structural beam and column supporting the fire
separation between the garage and living area
above, is acceptable if shown on the plans.
(city policy).
Please see additional corrections, or
remarks, on the following page.
The City of Carlsbad has contracted with Esgil
Corporation located at 9320 Chesapeake Drive,
Suite 208, San' Diego, California 92123;
telephone number of 619/560-1468, to perform the
plan check for your project. If you have any
questions regarding these plan check items,
please contact 'SAThQv
at Esgil Corporation. If you have any questions
regarding City Building permit procedures,
please contact Carter Darnell at the City of
Carlsbad, 1200 Elm Avenue,
telephone 619/438-5525.
Thank you.
Enclosures:
otk r
13
3/25/86
Date 7 CITY OF CARLSBAD
Prepared by Bldg. Dept.
VALUATION AND PLAN CHECK FEE M,,Esgil
PLAN CHECK NO.
BUILDING ADDRESS ,3S1 (cS'(e\.
APPLICANT/CONTACT PHONE NO. 7S3-
BUILDING OCCUPANCY DESIGNER PHONE -
TYPE OF -CONSTRUCTION L-,J CONTRACTOR PHONE —
BUILDING PORTION BUILDING AREA VALUATION
MULTIPLIER
VALUE
d L4 f33(3'..-
Ga
Air Conditioning
Cornmerciál
Residential Res. or Comm.
-Fire Sprinklers
Total Value
Fee Adjusted To Reflect 0 Energy Regulations (Fee x 1.1)
DI-landicapped Regulations (Fee x 1.065)
Building Permit Fee $_
Plan Check Fee $ 3'-)t. 70
COMMENTS:
I
PLAN CHECK NO. g -36o ADDRESS Received
PLANNING JUL 1 o
ZONE: TYPE OF PROJECT AND USE: 5t23 CITY OF CARLSBAD
DEVELOP. PROC SRV. DV
SCHOOL DISTRICT: SAN DIEGUITO ENCINITAS CARLSBAD SAN MARCOS
SETBACKS: FRONT SIDE. V1-. REAR
DISCRETIONARY ACTIONS: j
REDEVELOPMENT PERMIT REQUIRED:___________________________________________________
LANDSCAPE
1--
LANDSCAPE PLAN COMMENTS:___________________________________________________
Lu
ENVIRONMENTAL REQUIRED:j If
Vt
LU
ADDITIONAL COMMENTS: cDi-
0
>4-'
uc
OK TO ISSUE: DATE:
ENGINEERING
LEGAL DESCRIPTION VERIFIED? APN CHECKED?
PARK-IN-LIEU QUADRANT: 4 —, FEE PER UNIT: 04j/.4 _
-
7 - / sp ior x 4Z'r / P.F.F.,: TRAFFIC IMPACT FEE PER tNIT: -
___________ TO TA'FE E:
/
FACILITIES MGMT.
Z4a -*/4e-A,
IMPROVEMENTS: P1'
TOTAL FEE:__________________
FEE: ,1/T/1V BRIDGE & THOROUGHFARE
-f
FEE: A0Z~Woontae7-
Ic - —
FIELD CHECK DATE & INITIALS: 7%(/' RIGHT-OF-WAY
:44 -24a,..,Z7
D U. SEWER:
ftok
LATERAL
____________
Z -
INDUSTRIAL WASTE PERMIT: £i'27
GRADING PERMIT:f',,*T _ OK. GRADING
RAINAGE
ED
I)
ADDITIONAL COMMENTS:
OK TO —-----DA-TE --
)PD2:DPD6:07/17/86
1
I I
DEVELOPMENTAL
SERVICES
BUILDING DEPARTMENT
1200 ELM AVENUE
CARLSBAD. CALIFORNIA 92008.1989
(619) 438-5525
DEDICATIONS OF LAND AND FEES FOR SCHOOL DISTRICTS
- CHAPTER 21.55 CARLSBAD MUNICIPAL CODE
RETURN TO: .BUILDING DEPARTMENT
City of Carlsbad
1200 Elm Avenue
Carlsbad, CA 92008
FROM: School District SMJ DIEGLJITO UNION HIGH SCHOOL DISTRICT Name of District
.....--.. -
WPlan Check No. 036 ffective Date
Date Plan Check Fee Pd.
Property Owner's Name
Project Address 2 Se ? 4_I43 h9
Project Site Legal Description -OT 33 LII 7I4 ..SU714 LMJ/7 AJO!
Project Site Assessor's Parcel No. 4J 2-Se, —36o-- t_
Project Description - Incl. no. of dwelling units I SF - 2 bd
Department.
Official
Signature Title Date
I SCHOOL DIStRICT CERTIFICATION
I certify that the recriixemsits of Chapter 21.5 of the Carlsbad 4.ltidpa1 Code
r sthooj facilities dicatwr of land and fees have been satisfied for the
described p oject,,ø J -
Authorized S1 District Offi.a./ . V Coordinator 9-8-86 Signature 7fi Title Date
Note to Applicant: A review of one set
• • Plans may be required by the school district.
...
ENCINITAS UNION SCHOOL DISTRICT
189 Union Street
Encinitas, CA 92024
Telephone: (619)753-1152
Dedication of Land or Fees for School Districts
(Title 8, Division 2, County Code)
TO: The City of Carlsbad
1200 Elm Avenue
Carlsbad, CA 92008 Effective_________________________ Date Paid Plan Check Fe
. '** It *** It **:*** It It It It *** It It It It ** *
PROPERTY OWNER'S NAME Hobson, Denis
ADDRESS 7638 Calle M&de.r.a Carlsbad 92008 TELEPHONE 7S3-0980
PROJECT NAME (if applicable) none
PROJECT LOCATION2562 La Costa Avenue, Carlsbad 92008
ASSESSOR'S PARCEL NO. 216 360
H : TOTAL NUMBER OF DWELLING UNITS_________
App ii ca t
. . . Signature Title Date
- *'-* • *It It It *'* * * It It It It * * * It It * It * It It * It It * It * It * * *
School District Certification
No. bedrooms/like rooms 2
I certify that the requirements of Title 8, Division 2 of the
County Code for school facilities dedication of land, or fees
have been satisfied for the above described project.
TROM. SUPERINTENDENT
of
..
''•
1;p1-mbr_R r_1986
• Date •
-S . It It It It * * It It * * It It It It * * * * It It * IF It It It It It * It * It It It It It
NOTE TO ) A review of one set of plans is
•
APPIIC1T) required by the school district.
}Di• O. 01-021
Otrt but Ior9:
- Mt.• Appllc.nl S • Yellow District
Plek: Applicant
Plan Check No.
12
LEUCADIA COUNTY WATER DISTRIC1
APPLICATION FOR SEWER SERVICE
Owner's Name Eu&en Phone No. (213)876-1476
Mailing Address 1533 Nt Street _____
Hollywood, Ca 90046
Service Address: _________ La Costa Avenue
Tract Description: _jpt 33, Sôuth__/
Assessor's Parcel No. - - /2.
Type of Building - single family_ No. Units i Connection Fee $ 1500.00
I.ateral Size: 4" - 6" 8" -
Saddle - Easement Connection __(pre-pd 200.00)
Extra Footage: @ $________ Extra Depth: ____ @ $ 1300.00
Lateral Fee
Amount Rec'd $1,3c7.00 Prora ted S
Ck. Mo/Cash E132~L_
ce ewe
- Servi ce e
Date
Total
Rec'dBy $ 1500.00 ______
The application must be signed by the owner (or his authorized representative) of
the property to be served. The total charges must be paid to the District at the
time the application is submitted.
If a service lateral is required, it will be installed by the Leucadia County Water
District. The service lateral is that part of the sewer system that extends from
the main collection line in the street (or easement) to the point in the street (at
or near the applicant's property line) where the service lateral is connected to
the applicant's bi.iilding sewer. The applicant is responsible for the construction,
atthe applicant's expense, of the sewer pipeline (building sewer) from the appli-
cant's plumbing to the point in the stree (or easement) where a connection is made
to the service lateral.
The connection of the applicant's building sewer to the service lateral shall be
made by the applicant at his expense. The connection must be made in conformity
with the District's specifications, rules and regulations; and IT MUST BE INSPECTED
AND APPROVED BY THE DISTRICT BEFORE THE SEWER SYSTEM MAY BE USED BY THE APPLICANT.
THE APPLICANT, OR HIS AUTHORIZED REPRESENTATIVE, MUST NOTIFY THE DISTRICT AT THE
TIME INSPECTION IS DESIRED. ANY CONNECTION MADE TO THE SERVICE LATERAL OR COLLEC-
TION LINE WITHOUT PRIOR APPROVAL AND INSPECTION BY THE DISTRICT WILL BE CONSIDERED
INVALID AND WILL NOT BE ACKNOWLEDGED.
The prorated sewer service fee is based upon the date the District estimates that
service will begin and covers the balance of the fiscal year. There will be no
additional fee or refund if service actually conrnences on a different date. For
succeeding fiscal years, the sewer service fee will be collected or the. tax roil
in the same manner as property taxes.
The undersigned hereby agrees that the above information given is correct and agrees
to the conditions as stated.
Owner s Sinnature Date Account to.
ATTENTION PROPERTY OWNER:
An "owner-builder" building permit has been applied for in your name and bearing your
signature.
Please complete and return this information in the envelope provided at your earliest
opportunity to avoid unnecessary delay in processing and issuing your building peiit.
No building permit will be issued until this verification is received.
i. I personally plan to provide the. major labor and,materials for construction of
the proposed property improvement (yes or no)
I (31Ihave not) signed the application for a building permit.
I have contracted with the following person (firm) to provide the proposed construct
Name Phone
Address Contractors License No.
City
I plan to provide portions of the work, but I have hired the following person to
coordinate, supervise and provide the major work.
Name Phone
Address Contractors License NO.
City
I will provide some of the work but I have contracted (hired) the following persons
to provide the work indicated:
Name Address Phone Type of Work
Signed: Property Owner
Social Security Number 362-- 36z_- 7b2-3
Date: 14- 9
EACH SUBCONTRACTOR WILL BE INSTRUCTED TO OBTAIN A CITY OF CARLSBAD BUSINESS LICENSE
AND FURNISH A CERTIFICATE OF WORKMAN'S COMPENSATION TO THE CITY OF CARLSBAD.
Initials
Signature
DEVELOPMENTAL
SERVICES
BUILDING DEPARTMENT
1200 ELM AVENUE
CARLSBAD, CALIFORNIA 92006-9
(619) 435.5525
C itp of (arLsbab
Dear Property Owner:
An application for a building permit has been submitted In your name listing yourself
as the builder of the property Improvements specified. For your protection you should be
aware that as "owner-builder' you are the responsible party of record on such L permit.
Building permits are not required to be signed by the prooerty owners unless tney are
personally performing their own work. If your work is being performed by someone other
than yourself, you may protect yourself from possible liability if that person applies foi
the proper permit in his or her name.
Contractors are required by law to be licensed and bonded by the State of California and
to have a business license from the City of Carlsbad. They are also required by law to
put their license number on all permits for which they apply.
If you plan to do your own work, with the exception of various trades that you plan to
subcontract, you should be aware of the following information for your benefit and pro-
tection. If you employ or otherwise engage any persons other•thafl your immediate family,
and the work (including material and other costs) is $200 or more for the entire project,
and such persons are not licensed as contractors or subcontractors, then you may be an
employer. If you are an employer, you must register with the state and federal qovernmer
as an employer and you are subject to several obligations Including state and federal
income withholding, federal social security taxes, workers' compensation insurance,
disability Insurance costs, and unemployment contributions. There maybe financial risks
for you if you do not carry Out these obliqations and these rfks are especially serious
with respect to workers' compensation insurance.
For specific information about your obligations under federal law, contact the Internal
Revenue Service (and, if you wish, the U.S. Small Business Administration). For more
soecific information about your obligations under state law, contact the Department of
Benefit Payments and the Division of Industrial Accidents.
If the structure is intended for sale, property owners who are not licensed contractors
are allowed to perform their work personally or through their own emoloyees, without
a licensed contractor or subcontractor, only under limited conditions.
A frequent practice of unlicensed persons professing to be contractors is to secure an
"owner-builder" building permit, erroneously implying that the property owner is providir
his or her own labor and material personally. Building permits are not required to be
signed by property owners unless they are performing their own work personally. Informa-
tion about licensed contractors may be obtained by contacting the Contractors State
License Board in your community or at 1020 N Street, Sacramento, CA 95814.
PLEASE COMPLETE AND RETURN THE ENCLOSED OWNER-BUILDER VERIFICATION FORM SO THAT WE CAN
CONFIRM THAT YOU ARE AWARE OF THESE MATTERS. THE BUILDING PERMIT WILL NOT BE ISSUED
UNTIL THE VERIFICATION IS RETURNED.
Very truly yours,
Building Department
City of Carlsbad