HomeMy WebLinkAbout2562 West Ranch St; ; CB161870; Permit{city of
Carlsbad
Print Date: 04/16/2018
Job Address;
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
2562 West Ranch St
BLDG-Residential
2081951000
$2,129,655.00
ROBERTSON RANCH WEST VILLAGE
Residential Permit
Work Class: Apartments
Lot#:
Reference#: DEV11017
Construction Type:
Bathrooms:
Orig. Plan Check#:
Plan Check#:
Status:
Applied:
Issued:
Permit
Finaled:
Inspector:
Final
Inspection:
Description: RESDNTL -APT MONTECITO: 13 UNIT APT BLDG TYPE 1 / 14,924 SF APT AREA/ 2,447 SF GARAGE (BLDG #3)
Applicant:
ALLIANCE LAND PLANNING AND ENGINEERING
INC
ELIZABETH SHOEMAKER
2248 Faraday Ave
Carlsbad, CA 92008-7208
760-431-9896
Total Fees:
Owner:
SHAPELL MONTECITO LLC
8383 Wilshire Blvd, 700
Beverly Hills, CA 90211-2400
323-988-7590
Total Payments To Date: Balance Due:
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES ff APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Permit No: CB161870
Closed -Finaled
05/12/2016
09/27/2016
MColl
4/16/2018 4:10:42PM
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
Permit
Print Date: 01/04/2019
Job Address: 2558 West Ranch St
Permit Type: BLDG-Migrated Work Class: BLDG-Migrated
Parcel No: 2081951000 Lot#:
Valuation: $ 0.00 Reference#: DEV11017
Occupancy Group: Construction Type
# Dwelling Units: Bathrooms:
Bedrooms: Orig. Plan Check#:
Plan Check#:
Project Title: ROBERTSON RANCH WEST VILLAGE
Description: SWPPP -MONTECITO APARTMENTS BUILDING #2
FEE
Total Fees: Tota I Payments To Date :
Building Division
Status:
Applied:
Issued:
Permit
Finaled:
Inspector:
Final
Inspection:
(city of
Carlsbad
Permit No: SW160291
Closed -Finaled
06/21/2016
09/27/2016
01/04/2019
AMOUNT
Balance Due:
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
1; ,, «,
, PERMIT INSPECTION HISTORY REPORT (C:8161870)
' ' ' , '
Permit Typo BLDG-Residential Application Date: 05/12/2016 Owner:
Work Class: Apartments Issue Date: 09/27/2016 Subdivision:
Status: Closed -Finaled Expiration Date: 08/22/2018 Address:
IVR Number· 714454
Scheduled
Date
Actual
Start Date Inspection Type Inspection No. Inspection Status Primary Inspector
04116/2018 04/16/2018
April 16, 2018
BLDG-Final
Inspection
055120-2018
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
Passed Michael Collins
COMMENTS
Ok to stage Units 102-103 only.
Prelim walk
SHAPELL MONTECITO LLC
2562 West Ranch St
Carlsbad, CA
Reinspection
Passed
Yes
Yes
Complete
Complete
Page8of8
. . '
• \-h ''..
0
" • i•.PERMIT INSPECTION HISTORY REPORT (CB161870)
~~ 6 " j ,,;_ ' > 0 , f
Permit Type: BLDG-Residential Application Date: 05/1212016 Owner: SHAPELL MONTECITO LLC
Work Class: Apartments Issue Oat(!: 0912712016 Subdivision:
Status-Closed -Finaled Expiration Dato: 08/22/2018 Address: 2562 West Ranch St
Carlsbad, CA
IVR Number: 714454
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re inspection Complete
c,•-••~~--•--•••
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready No
BLDG-Building Deficiency Yes
BLDG-Building Deficiency Units 302, 304-305 only Yes
BLDG-Building Deficiency Yes
10/31/2017 10/31/2017 BLDG-17 Interior 039285-2017 Passed Michael Collins Complete
Lath/Drywall
CheckHst Item COMMENTS Passed
BLDG-Building Deficiency Not ready No
BLDG-Building Deficiency Units 102, 201, 203. See card for notes Yes
BLDG-Building Deficiency Yes
BLDG-Building Deficiency Units 302, 304-305 only Yes
BLDG-Building Deficiency Yes
11/01/2017 11/01/2017 BLDG-17 Interior 039450-2017 Passed Michael Collins Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Units 101-103 Yes
01/25/2018 01/25/2018 BLDG-23 046896-2018 Passed Michael Collins Complete
Gas/Test/Repairs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
02/15/2018 02/15/2018 BLDG-33 Service 048922-2018 Cancelled Michael Collins Reinspection Complete
Change/Upgrade
Checklist !tom COMMENTS Passed
BLDG-Building Deficiency No
02/16/2018 02/16/2018 BLDG-Electric Meter 049105-2018 Passed Mlchael Collins Complete
Release
Checklist Item COMMENTS Passed
BLDG-Building Deficiency EMR emailed to SDGE, Units Yes
101-103,201-205,301-305 & HP
02/23/2018 02/23/2018 BLDG-33 Service 049683-2018 Passed Paul Burnette Complete
Change/Upgrade
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
04/11(2018 04/11/2018 BLDG-Final 054685-2018 Partial Pass Michael Collins Reinspection Incomplete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Prelim walk Yes
April 16, 2018 Page 7 of 8
'
,, ,',: PERMIT INSPECTION HISTORY REPORT (CB161870)
Permit Type: BLDG-Residential Application Date: 05/12/2016 Owner: SHAPELL MONTECITO LLC
Work Class: Apartments Issue Date: 09/27/2016 Subdivision:
Status: Closed -Finaled Expiration Date: 08/22/2018 Address: 2562 West Ranch St
Carlsbad, CA
IVR Number: 714454
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete
10!05/2017 10/05/2017 BLDG-84 Rough 036910-2017 Partial Pass Andy Krogh Reinspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Partial as noted on card Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
{Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
10/06/2017 10/06/2017 BLDG-18 Exterior 036990-2017 Passed Andy Krogh Complete
Lath/Drywall
BLDG-84 Rough 037052-2017 Passed Andy Krogh Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
10/13/2017 10/13/2017 BLDG-16 Insulation 037519-2017 Passed Michael Collins Complete
Checklist Item COMMENTS Passed
BLOG-Building Deficiency Walls & floors only. Need ceiling cert for Yes
blown.
BLDG-Building Deficiency Prelim No
10/2512017 10/25/2017 BLDG-17 Interior 038583-2017 Partial Pass Michael Collins Reinspectlon Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready No
BLOG-Building Deficiency Units 302, 304-305 only Yes
BLDG-Building Deficiency Yes
10/2712017 10/27/2017 BLDG-17 lnterlor 038664-2017 Passed Mlchael Collins Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Units 202,204-205,301,303 Yes
-------------·--
April 16, 2018 Page 6 of 8
" ' . , ,:: , ,hIJ,•;c . PERn.,JTJNSPECTfQN ~ISTORY REPORT (CB161870)
Pormit Type: BLDG-Residential Application Date: 05/12/2016 Owner: SHAPELL MONTECITO LLC
Work Class: Apartments 1ssun Date: 09/27/2016 Subdivision:
Status· Closed -Finaled Expiration Date 08/22/2018 Address: 2562 West Ranch St
Carlsbad, CA
IVR Nurnbor: 714454
Scheduled Actual Inspection Type Date Start Date Inspection No. Inspection Status Primary Inspector Reinspection Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Balcony hard lids, see card for pick up. Yes
BLDG-8u1ld1ng Deficiency Stair stringer and guard rail attachment Yes
prelim
08/29/2017 08/2912017 BLDG-14 033100-2017 Partial Pass Michael Collins Reinspection Incomplete
Frame/Steel/Bolting/
Welding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Secondary frame per lim Yes
08/30/2017 08/30/2017 BLDG-14 033400-2017 Partial Pass Michael Collins Reinspection Incomplete
Frame/SteelfBolting/
Welding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency pre lim 1st and 2nd drop ceiling areas Yes
BLDG-Building Deficiency Secondary frame pre lim Yes
09/19/2017 09/19/2017 BLDG-14 035113-2017 Passed Michael Collins Complete
Frame/Steel/Bolting/
Welding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Truss walk Yes
BLDG-15 035297-2017 Passed Michael Collins Complete
RooffReRoof (Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Truss walk completed Yes
0912112017 09/21/2017 BLDG-14 035589-2017 Passed Michael Collins Complete
Frame/Steel/Bolting/
Welding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency B1 balconies Yes
09(29/2017 09/29/2017 BLDG-27 Shower 036068-2017 Partial Pass Michael Collins Reinspection Incomplete
Pan/Tubs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Leaks at Unit 101-102 & 204 No
10/0212017 10/0212017 BLDG-27 Shower 036435-2017 Passed Michael Collins Complete
Pan!Tubs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Leaks at Units 101-102, 104 corrected. Yes
BLDG-Building Deficiency leaks at Unit 101-102 & 204 No
April 16, 2018 Page 5of8
' ' , .PERMIT INSPECTION HISTORY REPORT (CB161870)
Permit Type:
Work Class:
Status:
Scheduled
Date
BLDG-Residential
Apartments
Closed -Finaled
Actual
Start Date Inspection Type
Application Date: 05/12/2016 Owner:
Issue Date: 09/27/2016 Subdivision:
Expiration Date· 08/22/2018 Address:
IVR Number: 714454
Inspection No. Inspection Status Primary Inspector
08/0912017 08/09/2017 BLDG-24 031154-2017 Failed Michael Collins
RoughfTopout
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
08/10/2017 08/10/2017 BLDG-24 031266-2017
Rough/Topout
Checklist Item
BLDG-Building Deficiency
08/11/2017 08/1112017 BLDG-24 031420-2017
Rough/Topout
Checklist Item
BLDG-Building Deficiency
BLOG-Building Deficiency
08/16/2017 08/16/2017 BLDG-24 031653-2017
Rough/Topout
Checklist Item
BLDG-Building Deficiency
BLOG-Building Deficiency
BLDG-Building Deficiency
Checklist Item
BLDG-Building Deficiency
08/18/2017 08/18/2017 BLDG-14 032174-2017
Frame/Steel/Boltlng/
Welding (Decks)
Checklist Item
BLDG-Building Deficiency
08/21/2017 08/21/2017 BLDG-15 032458-2017
Roof/ReRoof (Patio)
Checklist Item
BLOG-Building Deficiency
08/22/2017 08/22/2017 BLDG-15 032445-2017
Roof/ReRoof (Patio)
Checklist Item
BLDG-Building Deficiency
08/23/2017 08/23/2017 BLDG-14 032678-2017
Frame/Steel/Bolting/
Welding (Decks) ----,_, ___ ".--... --
April 16, 2018
COMMENTS
Not ready
No access to building
Passed Michael Colllns
COMMENTS
Roof drains ck and water supply to each
unitok.
Failed Andy Krogh
COMMENTS
Not ready
No access to building
Passed
COMMENTS
Waste and vent only
Not ready
No access to building
COMMENTS
Mlchael comns
Completed waste/vent only
Partial Pass Michael Collins
COMMENTS
Balcony hard lids, see card for pick up.
Passed Michael Collins
COMMENTS
Truss walk, minor pick up.
Passed Michael Collins
COMMENTS
Truss walk
Passed Michael Collins
SHAPELL MONTECITO LLC
2562 West Ranch St
Carlsbad, CA
Reinspection Complete
Relnspection Complete
Passed
No
No
Complete
Passod
Yes
Reinspectlon Complete
Passed
No
No
Complete
Passed
Yes
No
No
Passed
Yes
Re inspection Incomplete
Passed
Yes
Complete
Passed
Yes
Complete
Passed
Yes
Complete
Page 4 of 8
, PERMIT INSPECTION HISTORY REPORT (CB161870)
Permit Type: BLDG-Residential Application Date: 05/12/2016 Owner: SHAPELL MONTECITO LLC
Work Class: Apartments Issue Date: 09/27/2016 Subdivision:
Status: Closed -Finaled Expiration Date: 08/22/2018 Address: 2562 West Ranch St
Carlsbad, CA
IVR Number: 714454
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete
07/1912017 07/19/2017 BLDG-13 Shear 029197-2017 Passed Michael Collins Complete
Panels/HD (Ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Partial No
BLDG-Building Deficiency Minor pick up. Yes
07125/2017 07/25/2017 BLDG-13 Shear 029711-2017 Passed Michael Collins Complete
Panels/HD (Ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Secondary frame Yes
BLDG-17 Interior 029710-2017 Failed Michael Colllns Reinspection Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLOG-Building Deficiency Not ready No
BLDG-Building Deficiency Yes
07/26/2017 07/26/2017 BLOG-13 Shear 029728-2017 Cancelled Michael Collins Reinspection Complete
Panels/HD (ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Requested inspection elsewhere on site. No
BLDG-18 Exterior 029729-2017 Cancelled Michael Collins Reinspection Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Requested inspection elsewhere on site No
08102/2017 0810212017 BLDG-84 Rough 030587-2017 Passed Michael Colllns Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Southwest corne secondary frame perlim Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical No
BLDG-44 Yes
Rough-Ducts-Dampers
08/07/2017 08/07/2017 BLDG-24 030867-2017 Failed Michael Collins Reinspectlon Complete
Rough/To pout
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No access to building No
Aprll 16, 2018 Page3of8
f 1 ?1
. PERMIT INSPECTION HISTORY REPORT (CB161870)
Permit Type: BLDG-Residential Application Date: 05/12/2016 Owner:
Wo(k Class: Apartments Issue Date: 09/27/2016 Subdivision:
Status: Closed -Finaled Expiration Date: 08/22/2018 Address:
IVR Number: 714454
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector
Checklist Item COMMENTS
BLDG-Building Deficiency Truss walk
05/22/2017 05/22/2017 BLDG-14 024019-2017 Failed Michael Collins
Frame/Steel/Bolting/
Welding (Decks)
Checklist Item COMMENTS
BLDG-Building Deficiency Complete all load transfer hardware & AB's.
BLDG-16 lnsulatlon 024018-2017 Failed Michael Collins
Checklist Item COMMENTS
BLDG-Building Deficiency
06/13/2017 06113/2017 BLDG-14 026245-2017 Partial Pass Michael Collins
Frame/Steel/Boltlng/
Welding (Decks)
Checklist Item COMMENTS
BLDG-Building Deficiency Garage pre lim for utility chase.
BLDG-Building Deficiency Complete all load transfer hardware & AB's.
06/15/2017 06/15/2017 BLDG-13 Shear 026510-2017 Passed Michael Collins
Panels/HD (ok to
wrap)
Checklist Item COMMENTS
BLDG-Building Deficiency Garage wall pre lim at soffit
BLDG-16 Insulation 026365-2017 Failed Michael Collins
Checklist Item COMMENTS
BLDG-Building Deficiency Pre 1im
07/03/2017 0710312017 BLOG-17 Interior 027751-2017 Partial Pass Jonathan West
LathfDrywall
Checklist Item COMMENTS
BLDG-Building Deficiency
07/17/2017 0711812017 BLDG-13 Shear
Panels/HD (ok to
wrap)
028884-2017 Parttal Pass Michael Collins
April 16, 2018
Checklist Item
BLDG-Building Deficiency
BLDG-17 Interior
LathfDrywall
028883-2017
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
Partial
Failed Michael Collins
COMMENTS
Not ready
SHAPELL MONTECITO LLC
2562 West Ranch St
Carlsbad, CA
Reinspection
Passed
Yes
Reinspection
Passed
No
Reinspection
Passed
No
Reinspection
Passed
Yes
No
Passed
Yes
Reinspection
Passed
No
Reinspection
Passed
Yes
Reinspectlon
Passed
No
Reinspection
Passed
No
Yes
Complete
Complete
Complete
Incomplete
Complete
Complete
Incomplete
Incomplete
Complete
Page 2 of 8
'11~ "
PERMIT INSPECTION HISTORY REPORT (CB161870)
Permit Type: BLDG-Residential Application Date: 0511212016 Owner: SHAPELL MONTECITO LLC
Work Cla'::is: Apartments Issue Date: 09/2712016 Subdivision:
Status: Closed -Finaled Expiration Date: 0812212018 Address: 2562 West Ranch St
Carlsbad, CA
IVR Number: 714454
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete
12/01/2017 BLDG-23 042201-2017 Partial Pass Andy Krogh Relnspection Incomplete
Gas/Test/Repairs
Checklist ltum COMMENTS Passed
BLDG-Building Deficiency 1 unit fail, remaining units ok No
11/02/2016 11/02/2016 BLOG-24 002203-2016 Passed Paul Burnette Complete
Rough/Topout
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
11/14/2016 11/14/2016 BLOG-11 001007-2016 Passed Paul Burnette Complete
Foundation/Ftg/Pier
s (Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
03121/2017 03/21/2017 BLDG-14 017289-2017 Passed Michael Collins Complete
Frame/Steel/Botting/
Welding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Prelim 2nd floor, floor sheathing drag Yes
straps.
03130/2017 03130/2017 BLDG-15 018400-2017 Passed Michael Collins Complete
Roof/ReRoof {Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Pre lim 2nd floor drag straps at floor Yes
sheathing.
04/14/2017 04114/2017 BLDG-17 Interior 020099-2017 Passed Mlchael Collins Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency 3rd floor, pre lim floor drag nailing and CS$ Yes
strap.
05/08/2017 05/08(2017 BLDG-15 022617-2017 Falled Michael Collins Reinspectlon Complete
RooffReRoof (Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
05/10/2017 05/10/2017 BLDG-15 023074-2017 Passed Michael Collins Complete
Roof/ReRoof (Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Sheathing nailing only. Need truss walk.. Yes
05/11/2017 05/11/2017 BLDG-15 022964-2017 Partial Pass Michael Collins Reinspection Incomplete
Roof/ReRoof (Patio)
··--·---·----April 16, 2018 Page1of8
~-RECORD COPY
<__({jf)
~ Cl1Y Ot
CB161870 2562 WEST RANCH ST
MONTECITO: 13 UNIT APT CARLSBAD
Building Division INSPECTION RECORD BLDG TYPE 1 / 14.924 SF APT AREA/ 2,447 SF GARAGE
(BLDG #3)
RESDNTL APT li?J INSPECTION RECORD CARD WITH APPROVED
PLANS MUST BE KEPT ON THE JOB Lot#· 1 ALLIANCE LANO PLANNING &
li?J CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION
li?J FOR BUILDING INSPECTION CALL! 760-602-2725
OR GO TO: www.car,Sbadca.goy/BuHcQng AND CUCK ON
"Request lnspectlonH
DATE: Cj, L,7 -1 lr
ENGINEERING INC
If "YEs·· ,s checked below that O,vision·s approval is required prj_or to requesting a F,nal Building Inspection. If you have any questions
please call the applic;ihle divisions at the phone numbers provided below. After all required approvals arc signed off-fax to
760 602-8560. email to hldginspection<,_'"'carlshadca.gov or bring in a COPY of thi<, card to: 1635 Faraday Ave. Carlsbad.
Required Prior to Requesting Building Final If Checked YES
Plannlng/landscape 760-944-8463 Allow 48 hours
CM&I (Engineering lllJl)«tlons1 7 60-438-3891 Call before 2 pm
Fire Prevention 761H>02-4660 Allow 48 ho1,1rs
Date Inspector
#12 REINFORCE0STEEL
#66 MASONRY PRE GROUT
0 GROUT O WALL DRAINS
#10 TILT PANELS
#11 POUR STRIPS
#11 COLUMN FOOTINGS
#14
#15
#13
#16 INSULATION
#18 EXTERIOR LA111
#17 INTERIOR LATH & DRYWALL DRYWALL,EXT LATH, GAS TES (17,18,23)
#51 P0OLEXCA/STEEL/IOND/FENCE #83 ROOF SHEATING, EXT SHEAR (13,151
#84 FRAMER0UGH COMBO (14,24,34,44)
#85 T•Bar(14,24,34,441
ANAL OCCUPANCY (19,29,39,49)
A/S UNDERGROUND VISUAL
#27 A/S UNDERGROUND HYDRO
#23 A/S UNDERGROUND FLUSH
#25 WATER HEATER A/S OVERHEAD VISUAL
#28 A/S OVERHEAD HYDROSTATIC
A/SANAL
F/AR0UGH-IN
F/AANAL
#603 FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN
#605 NOTICE TO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST
#607 WRITTEN WARNING AXED EXTINGUISHING SYSTEM ANAL
#609 NOTICE OF VIOLATION MEDICAL GAS PRESSURE TEST
#610 VERBAL WARNING MEDICAL GAS FINAL
REV 10/2012 SEE BACK FOR SPECIAi. NOTES
Lily De la Mora
From:
Sent:
Gustavo Alvarado < gustavo.alvarado@ampam.com >
Wednesday, April 18, 2018 8:16 AM
To: Lily De la Mora
Subject: Rv: Water heater connections -Carlsbad, CA
Good morning-lily. Will you please forward this update information to all. Superintendents at this job its needed for finals at bks 4,3,2
thanks for the help have I great day
------Mensaje original------
Desde: Roland Kazandjian
Fecha: mie., abr. 18, 2018 7:44
Para: Terry Sober;
Cc:Gustavo Alvarado;
Asunto:FW: Water heater connections -Carlsbad, CA
Terry,
RECORD COPY
Please circulate to the appropriate parties at the job (superintends).
Thanks,
AMPAM I Roland Kazandjian I t 310.427.7202 I m 310.420.4782
From: Smith, Chris (Corona) [mailto:Chris.Smith@Lubrizol.com]
Sent: Wednesday, April 18, 2018 7:30 AM
To: gustavoglezalvarado@gmail.com; Roland Kazandjian <Roland.kazandjian@ampam.com>;
robert.graham@ampam.com
Cc: Landon, Jeff <Jeff.Landon@Lubrizol.com>
Subject: Water heater connections -Carlsbad, CA
Good morning Gustavo.
The 2013 CA Plumbing Code IS 20 2.9.3 Water Heaters: There shall be a minimum of six (6) inches of metallic piping
between a gas water heater connection and CPVC tubing. CPVC tubing may be installed downstream of instantaneous
(coil or immersion) water heaters provided that the water heater temperature controls are maintained for maximum
temperature of 180°F.
A copper water heater flex, normally 18" and 24" long and copper (metallic), are an approved method of metallic
separation.
Please contact me if you have any questions or need additional information.
Regards,
Chris' Smith
Piping System Consultant
The Lubrizol Corporation, a Berkshire Hathaway company
Representing FlowGuard Gold®, BlazeMaster®, & Corzan® CPVC Systems
C:: 951-256-0443
0:: 951-371-4736
chris.smith@lubrizol.com
www.lubrizolcpvc.com
Lubrizol Rt:~ .. vRD COPY
Both the individual sending this e-mail and The Lubrizol Corporation intend that this electronic message be used exclusively by the individual
or entity to which it is intended to be addressed, lhis message may contain information that is privileged, confidential and thereby exempt
and protected from unauthorized disclosure under applicable law. If the reader of this message is not the intended recipient, or an employee
or agent responsible for delivering the message to the intended recipient, be aware that any disclosure, dissemination, distribution or copying
of this communication, or the use of its contents, is not authorized and is strictly prohibited. If you have received this communication and are
not the intended recipient, please notify the sender immediately and permanently delete the original message from your e-mail system.
http://online.lubrizol.com/email/disclaimer/cliquez ici pour traduction en francais.htm
http://online.lubrizol.com/email/disclaimer/Klicken Sie hier fur die deutsche Ubersetzung.htm
http://online.lubrizol.com/email/disclaimer/Clicar aqui para versao em Portugues.htm
http://online.lubrizol.com/email/disclaimer/De un die aqui para su traduccion al espanol.htm
http://online.lubrizol.com/email/disclaimer/Chinese.htm
http:// onl ine. lu brizol .com/email/disclai mer/]a panese. htm
2