HomeMy WebLinkAbout2567 Arundel Ave; ; CBR2017-0561; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Print Date: 03/23/2017 Residential Permit Permit No: CBR2017-0561
www.carlsbadca.gov
Job Address:2567 Arundel Ave
Permit Type:BLDG-Residential Work Class:Cogen Status:Closed -Finaled
Parcel No:2131702800 Lot #:Applied:03/20/2017
Valuation:$7,001.00 Reference #:Issued:
Occupancy Group:Construction Type:Finaled:
# Dwelling Units:Bathrooms:Inspector:
Bedrooms:Orig. Plan Check #:
Plan Check #:
Project Title:
Description:VIERNES: ELECTRICAL VEHICLE CHARGER 40A
Owner:Co-Applicant:
TRUST VIERNES FAMILY 2008 TRUST SMITH ELECTRICAL CONTRACTORS INC
11-23-08
2567 Arundel Ave 206 Greenfield Dr
CARLSBAD, CA 92020 El Cajon, CA 92020-1956
619-758-9829
BUILDING PERMIT FEE $2000+$97.22
BUILDING PLAN CHECK FEE (BLDG)$68.05
SB1473 BUILDING STANDARDS FEE $1.00
STRONG MOTION-RESIDENTIAL $0.91
Total Fees:$167.18 Total Payments To Date:$167.18 Balance Due:$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction."You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
I fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project.NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
.,.
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE:0 PLANNING 0 ENGINEERING 0 BUILDING 0 FIRE 0 HEALTH 0 HAZMAT/APCD
411 Building Permit Application Plan Check No.
Xim.%*#'1635 Faraday Ave., Carlsbad, CA 92008 Est. Value\7/
62Z.e) r7 -os 4 I
CITY 0 F Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit
CARLSBAD email: building@carlsbadca.gov
www.carlsbadca.gov Date 1-Z-0-11 SWPPP
JOB ADDRESS SUITEVSPACEVUNIT6 APN
2567 ARUNDEL AVENUE -_
CT/PROJECT #LOT#PHASE##OF UNITS # BEDROOMS #BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE OCC. GROUP
DESCRIPTION OF WORK:include Square Feet of Affected Area(s)
EVCS
EXISTING USE PROPOSED USE GARAGE (SF)PATIOS (SF)DECKS (SF)FIREPLACE AIR CONDITIONING FIRE SPRINKLERS
YES:).NOD YES ONO p YESD NOD
APPLICANT NAME (Primary Contact)APPLICANT NAME (Secondary Contact)Smith Electric Jennifer/Randy Cole
ADDRESS ADDRESS
206 GREENFIELD DR STE G 9880 Magnolia Ave #119
CITY STATE ZIP CITY STATE ZIP
EL CAJON CA 92020 Santee CA 92071
PHONE FAX PHONE FAX
(619) 758-9829 619-405-2648 619-330-4796
EMAIL EMAIL jennifer@permitrunner.net
PROPERTY OWNER NAME
,
CONTRACTOR BUS. NAMEEric Viernes Smith Electric
ADDRESS ADDRESS
2567 ARUNDEL AVENUE 206 GREENFIELD DR STE G
CITY STATE ZIP CITY STATE ZIP
Carlsbad CA 92009 EL CAJON CA 92020
:.1 PHONE FAX PHONE FAX
I 760-908-4279
,^1 EMAIL EMAIL
I
ARCH/DESIGNER NAME & ADDRESS STATE LIC. #STATE LIC.#CLASS CITY BUS. LIC.#
871200 C10
(Sec.7031.5 Business and Professions Code: Any City or County which requiresa permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires theapplicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of theBusiness and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a
civil penalty of not more than five hundred dollars ($500}).
WORKERS'COMPENSATION
Workers' Compensation Declaration: I hereby affirm under penaltyofperjury one of the following declarations:D I have and will maintain a certificate of consent to self•insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
ElI have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co.Everest National Policy No.7600010140141 Expiration Date 10123/17
I
ihi
section need not be completed if the permit is for one hundred dollars ($100) or less.
Certificate of Exemption:I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California.WARNING: Failure to secure workers' compensation .•.a Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (8100,000), in
addition to the cost of compensation, damages as ••.•for Ar -qi 3706 of the Labor code, interest and attorney's fees.
AS CONTRACTOR SIGNATURE id LI af ...i.L.0 AGENT DATE 3/20/17
11 OWNER -BUILDER DECLARATION
.....imir
I hereby affirm that) am exempt from Contractor's License Law for the following reason:
ElI,as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).0 I,as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
Al Ei I am exempt under Section Business and Professions Code for this reason:
1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement.ElYes EINo
2.I (have / have not) signed an application for a building permit for the proposed work.
3.I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number):
4.I plan to provide portions of the work, butI have hired the following person to coordinate, supervise and provide the major work (include name / address I phone I contractors' license number):
5.Iwill provide some of the work, butI have contracted (hired) the following persons to provide the work indicated (include name/address / phone / type of work):
.06PROPERTY OWNER SIGNATURE DAGENT DATE
COMPLETE THIS SECTION FOR NON -RESIDENTIAL BUILDING PERMITS ONLY
Is the applicant or future building oCcupant required to submit a business plan, acutely hazardous materials registration form orrisk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act?CI Yes Cl No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?CI Yes CI No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site?CI Yes 1:1 No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name Lender's Address
APPLICANT CERTIFICATION
Icatty that!have read the application and state thatthe above information Is correct and thatthe intonationon the plans is accurate.I agree tocomplytith all Cis/ordinances and State laws relating to building construction.
I hereby authorize representativeofthe CityofCarlsbad to enter upon the above mentioned property for impaction purposes.I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY INANY WAY ACCRUE AGAINST SAID CITYIN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over50' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Building Offniaa undo' the provisionsof '
r .shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within
180 days from the dateofsuch permit or if the building or work 4 .4• by
410.
•is suspended or abandoned at any time after the work is commenced fora period of 180 days (Section 106.4.4 Uniform Building Code).
RSAPPUCANT'SSIGNATURE fr a •DATE 3/20/17
PERMIT INSPECTION HISTORY REPORT (CBR2017-0561)
Permit Type:BLDG-Residential Application Date:03/20/2017 Owner:TRUST VIERNES FAMILY 2008
TRUST 11 -23-08
Work Class:Cogen Issue Date:Subdivision:CARLSBAD TCT#02-14 BRESSI
RANCH UNIT#05
Status:Closed -Fineled Expiration Date:09/19/2017 Address:2567 Arundel Ave
Carlsbad, CA 92009-3066
IVR Number:2628
Scheduled Actual
Date Start Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete
03/23/2017 03/23/2017 BLDG-34 Rough 017427-2017 Passed Peter Dreibelbis Complete
Electrical
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Final 017428-2017 Passed Peter Drelbelbis Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Electrical Final Yes
is
March 23, 2017 Page 1 of 1
4111W
C1/4
City of CIRCUIT CARD
Development Services
Building Division
B-36 1635 Faraday AvenueCarlsbad760-602-2719
www.carlsbadca.gov
THIS CARD MUST BE FILLED OUT AND AVAILABLE AT THE SERVICE EQUIPMENT FOR THE ROUGH INSPECTION
Address:250i Arunict five Permit Number es12201i -oslo
Owner:C \I I ernes Phonell
•
1514
-427 Area In Sq. Ft.
Contractor roily\ EtrcifirQt Phone:ipk ••cicaA
PANEL:A.I.C.VOLTS 0 WIRE
BKR BKRLOCATIONCKTsiZEMISCRECRECLTGMISC CKT LOCATIONSIZE
WIRE
TYPE SIZE
WIRE
TYPE SIZE _(I./tonal 50 Go 04 ev ovri-ti -2-.
_4
5 6
,.
7 8
9.10
',
11 12
.,
13 .14
15 16
17 18-
19 20.._,.1
'WI i
tA
21 "7 .
22
23
r
.•'-
2625L...--7-,...— 27 ..."287.
29 .--30
..e31/'
34 32
.."
35 36
.37 38-
40.,._
42
MAIN: tt.'S 3.00 AMP40.USE 0 MLO Computed Load C2-
Celoolaion Worksheet on beck
AMPS
BUS:2 0 A •
Branch circuits required:Service entrance or feeder conductors:
AL B) Two Small Appliance Circuits 210 -11(e)
C) Insulation:
Type:D El
0) Conduit Cu Size:
A) Lighting Circuits 220 -3(b), 4(d)A) Size: No.B)
C) Laundry Circuit 220 -16(b)Service ground/bond:
A) Size: No.4-4 B) Type:0 CU 0 AL E) Bathroom
C) Clamp location(s):
-UFER 250 -50(c)
D) Central Heating Equipment 422 -12
210 -52(d)
Remarks:
..Water Pipe 250 -104
G Ground Rod 250 -520
GFCI locations 210 -8, 680 -70:/ certify that all terminations have been torqued in accordance with manufacturer's
O Bathroom(s)0 Kitchen instructions and that the work shown on this circuit card represents the full extentofoGarage(s)OHydromassage Tub the work performed under this permit.0 Outdoors 0 0 Owner
AFCI Protected Circ. 210 -12 VContractor S ik."1 -1"i-N0Bedroom(s)aligned //„Ab6---Orate 7—Z5—/7-
B-36 Page 1 of 2 Rev. 03/09
SINGLE FAMILY EXISTING DWELLING
ELECTRICAL SERVICE CALCULATIONS
2014 NEC -220.83 (A) -EXISTING DWELLING NO ADDITIONAL AIR CONDITIONING TO BE INSTALLED
E-256 -E.Viemes, 2567 Arundel Avenue, Carlsbad, CA 92009
**SMITH ELECTRICAL CONTRACTORS **
1.GENERAL LIGHTING LOADS
Dwelling 4608 Sq. Ft x 3 VA (220.12)=13824 VA
Small appliance loads (220.52)1,500 VA x 2 circuits =3000 VA
Laundry load (220.52)(B)1,500 VA x 1 circuits =1500 VA
General Lighting Loads Total:18324 VA
2.COOKING EQUIPMENT LOADS (220.55)FLA
Oven 9,192 VA
Cook top gas VA
Other 0 VA
Cooking Equipment Load Total:9192 VA
3.ELECTRIC DRYER (220.54), Nameplate, 5,000 VA min.
Dryer gas VA
Dryer load total:0 VA
4.FIXED APPLIANCE LOADS (220.53)
Wine Cooler VA 2nd Fridge 780 VA
Dishwasher 960 VA Water Heater 5616 VA
Microwave 1650 VA Other 0 VA
Disposal 1080 VA Other 0 VA
Fixed appliance load total:10086 VA
5.MOTOR LOAD(S)(220.18) (A)No pool or spa 0 VA
is
6.TESLA charging station (625.41)40A x 125%12000 VA
7.HEATING OR AC LOAD (220.82) (B)2 A/C units 10896 VA
8.LOADS TOTAL (Total from lines 1-7)60498 VA
9.APPLYING DEMAND FACTORS (220.83) (A)
First 8,000 VA x 100%8000 VA
Remaining load x 40%20999 VA
10.OPTIONAL LOADS TOTAL:(From line 9)28999 VA
11.COMPUTED LOAD =optional loads total / 240 volts:121 AMPS
12.EXISTING SIZE SERVICE:200 AMPS