Loading...
HomeMy WebLinkAbout2569 DISCOVERY RD; ; CB041619; Permit05-14-2004 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Retaining Wall Permit Permit No CB041619 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Reference # Project Title 2569 DISCOVERY RD CBAD RETAIN 2131303000 Lot# $5,213 00 Construction Type 30 NEW BRESSI RANCH PA 6-- 331 SF RETAIN WALL PER CITY AND/OR SDRS C-1 Status Applied Entered By Plan Approved Issued Plan Check* ISSUED 04/21/2004 SB 05/14/2004 05/14/2004 PC04-40 Inspect Area Applicant GREYSTONE HOMES 101 5973 AVENIDA ENCINAS CARLSBAD CA 92009 760-804-7700 Owner Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Strong Motion Fee Renewal Fee Add'l Renewal Fee Other Building Fee Additional Fees TOTAL PERMIT FEES $6889 $000 $4478 $000 $1 00 $000 $000 $000 $000 $11467 Total Fees $11467 Total Payments To Date $000 Balance Due $11467 05/14/04 0002 OJ 114-07 SIGNATU City of Carlsbad Bldg Inspection Request For 08/25/2004 Permit* CB041619 Title BRESSI RANCH PA 6- 331 SF Description RETAIN WALL PER CITY AND/OR SDRS C-1 Inspector Assignment PS 2569 DISCOVERY RD Lot 30 Type RETAIN Sub Type Job Address Suite Location APPLICANT GREYSTONE HOMES Owner Remarks Phone 7605228206 Inspector Total Time CD Description 69 Final Masonry omment Requested By PAUL Entered By CHRISTINE Associated PCRs/CVs Inspection History Date Description Act Insp Comments 05/20/2004 66 Grout AP PS 05/17/2004 61 Footing AP PS FOOTING OBSERVATION SUMMARY Leighton and Associates, Inc A LEIGHTON GROUP COMPANY Project Name Location Plan File No Date Project No Permit No Unit/Phase^tStfs.)-}3 3/5 Referenced Geotechnical Report(s) 4 -4 ~7ff£0ui,tJ 1 2 Observation Summary >" ' : Initials A representative of Leighton and Associates observed onsite soil conditions Soil conditions at Date *ne Sl*e are substantially in conformance with those assumed in the geotechnical report Initials Date Initials Date Initials Date A representative of Leighton and Associates observed and measured footing excavation depth/width Footing excavations extend to proper depth and bearing strata and are in general conformance with recommendations of the geotechnical report A representative of Leighton and Associates measured footing setback from slope face The setback was in general accordance with the recommendations of the geotechnical report /A/ Notes to Superintendent/Foreman ^ Footing excavations should be cleaned of loose debris aftd thoroughly moistened just prior to placing concrete '• ' 2 Based on expansion potential of underlying soils, presoaking of soil below slabs may be recommended Consult the geotechnical report for presoaking recommendations We note that clayey soils may take an extended penod of time and the contractor should schedule accordingly 3 In the event of a site change subsequent to our footing observation and pnor to concrete placement (i e , heavy rain, etc ), we should be contacted to perform additional site observations Note to Building Inspector 1 Soil compaction test results, including depth of fill, relative compaction, bearing values, and soil expansion index test results are contained in the As-Graded Geotechnical Report provided at the completion of grading hton and Associates, Inc Date Gold - Field 3930 R/0403