Loading...
HomeMy WebLinkAbout2571 STATE ST; ; CB152728; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 02-18-2016 Residential Permit Permit No: CB152728 Building Inspection Request Line (760) 602-2725 Job Address:2571 STATE ST CBAD Permit Type:RESDNTL Sub Type: CONDO Status:ISSUED Parcel No:2030543427 Lot #:27 Applied: 08/21/2015 Valuation:$301,913.00 Constuction Type: 5B Entered By: JMA Occupancy Group:Reference #: CT130005 Plan Approved: 02/18/2016 # Dwelling Units:1 Structure Type: MF5+Issued: 02/18/2016 Bedrooms:0 Bathrooms:0 Inspect Area: PY Orig PC #: PC140037 Plan Check #: PC150048 Project Title:STATE ST. TOWNHOMES: PHS.6 B1 375 SF 1ST FLR COMMERCIAL/1,772 SF LIV/ 444 SF GAR/ 76 SF BALCONY/ 646 SF ROOF DECK Applicant:Owner: TAYLOR MORRISON OF CA, LLC STE 1450 100 SPECTRUM DR IRVINE CA 92618-4935 949-341 -1289 Building Permit $1,339.12 Meter Size FS1 Add'I Building Permit Fee $0.00 Add'I Red. Water Con. Fee $0.00 Plan Check $937.38 Meter Fee $317.00 Add'I Plan Check Fee ($500.00)SDCWA Fee $4,800.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $39.25 PFF (3105540)$5,494.82 Park in Lieu Fee $6,190.00 PFF (4305540)$5,072.14 Park Fee $0.00 License Tax (3104193)$0.00 LFM Fee $0.00 License Tax (4304193)$0.00 Bridge Fee $0.00 Traffic Impact Fee (3105541)$0.00 Other Bridge Fee $0.00 Traffic Impact Fee (4305541)$0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BTD #3 Fee $0.00 PLUMBING TOTAL $210.00 Renewal Fee $0.00 ELECTRICAL TOTAL $89.00 Add'I Renewal Fee $0.00 MECHANICAL TOTAL $65.38 Other Building Fee $0.00 Housing Impact Fee $0.00 HMP Fee $0.00 Housing InLieu Fee $0.00 Pot. Water Con. Fee $3,931.00 Housing Credit Fee $0.00 Meter Size FS1 Master Drainage Fee $0.00 Add'I Pot. Water Con. Fee $3.00 Sewer Fee $881.00 Recl. Water Con. Fee $0.00 Additional Fees $202.00 Green Bldg Stands (SB1473) Fee $13.00 Fire Sprinkler Fees $0.00 Green Bldg Stands Plan Chk Fee $0.00 TOTAL PERMIT FEES $29,084.09 Total Fees:$29,084.09 Total Payments to Date:$29,084.09 Balance Due:$0.00 FINAL PR AL Inspector:Date:/2.0/7 Clearance: NOTICE:Please take 11 approval of your project includes the "I 'ion"cf ees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exacti "have 93 days fi um the date this permit was issued protest imposition of these fees/wa.tions.If you protest them, you must followthe protest procedures forth in GPvemment rtriPSection 66020(a), and file the protest and any other required information with the City Manager for processing in accordance Wth Carlsbad Municipal Code Section 3.32030.Failure to timely follow that procedure will bar any subsewent legal action to attack review, sat aside, vdd, or annul their imposition. You are hereby FURT1-ER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and saber connection fees and capacity changes, nor planning, zoning, gracing or other similar application processing or service fees in connection with this project.NOR DOES IT APPLY to any fees/exactiors ofMich You have Previously been given a NOTICE sinilar to this. or as toMich the statute of limitations has previously otherwise PERMIT INSPECTION HISTORY REPORT (CB152728) Permit Type:BLDG-Residential Application Date:08/21/2015 Owner: Work Class:Condo Issue Date:02/18/2016 Subdivision: Status:Closed -Finaled Expiration Date:07/31/2017 Address:2571 State St Carlsbad, CA 11/R Number:708754 Scheduled Actual Date Start Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete 11/14/2016 BLDG-15 002294-2016 Passed Paul York Complete Roof/ReRoof (Patio) 11/10/2016 11/10/2016 BLDG-15 000576-2016 Partial Pass Paul York Reinspection Incomplete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 11/17/2016 11/17/2016 BLDG-17 Interior 001366-2016 Partial Pass Paul York Reinspection Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No Checklist Item COMMENTS Passed BLDG-Building Deficiency No 12/14/2016 12/14/2016 BLDG-13 Shear 005385-2016 Passed Paul York Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 01/18/2017 01/18/2017 BLDG-84 Rough 009947-2017 Passed Paul York Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 01/31/2017 01/30/2017 BLDG-82 Drywall,011761-2017 Passed Paul York Complete Exterior Lath, Gas Test, Hot Mop Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-17 Interior Lath-Drywall No BLDG-18 Exterior Lath and No Drywall BLDG-23 Gas-Test-Repairs No 03/16/2017 03/16/2017 BLDG-Electric Meter 016716-2017 Partial Pass Paul York Reinspection Incomplete Release Checklist Item COMMENTS Passed BLDG-Building Deficiency No April 13, 2017 Page 1 of 2 _,• PERMIT INSPECTION HISTORY REPORT (CB152728) Permit Type:BLDG-Residential Application Date:08/21/2015 Owner: Work Class:Condo Issue Date:02/18/2016 Subdivision: Status:Closed -Finaled Expiration Date:07/31/2017 Address:2571 State St Carlsbad, CA IVR Number:708754 Scheduled Actual Date Start Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete 04/06/2017 04/06/2017 BLDG-Fire Final 018886-2017 Passed Dominic Fieri Complete Checklist Item COMMENTS Passed FIRE-Building Final Yes 04/13/2017 04/13/2017 BLDG-Final 019861-2017 Passed Paul York Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes April 13, 2017 Page 2 of 2 Inspection List Permit*CB152728 Type:RESDNTL CONDO STATE ST. TOWNHOMES: PHS.6 B1 375 SF 1ST FLR COMMERCIAL/1,772 SF L Date Inspection Item Inspector Act Comments 10/12/2016 17 Interior Lath/Drywall PD PA 09/28/2016 17 Interior Lath/Drywall PY PA 09/06/201611 Ftg/Foundation/Piers PY AP 08/10/2016 21 Underground/Under Floor PY AP 08/10/2016 22 Sewer/Water Service PY AP Thursday, April 20, 2017 Page 1 of 1 Development ServicesCCity of CIRCUIT CARD Building Division Carlsbad B-36 •.1635 Faraday Avenue 760-602-2719 CO--www.carlsbadca.govt7 THIS CARD MUST BE FILLED OUT AND AVAILABLE AT THE SERVICE EQUIPMENT FOR THE ROUGH INSPECTION Address:-L.5-7(51..0..4, NA...p4-- Permit Number: Owner:Phone: Contractor:Phone: Area in Sq. Ft. PANEL:/Z.&A.I.C./24D VOLTS 241 0 0 WIRE BKR WIRE WIRE BKRLOCATIONCKTMISCRECRECLTGMISC CKT LOCATIONSIZESIZETYPESIZETYPESIZE 0/.02.tit 1 IC I((A)I t 1a tc 2 Pkitb...4 e A..9 Clagui."--3 ti-' tt t'I Lk ('c 4 ni.*C.JC•6/wc Di Kt.usit01/45 (5 .U ti <ki.2.0 6 Poi,c-/CI lig 3 7 [5- f3 6 (4 -0-rto 8 X /4-c//h-( 14.-51-c. sot_9 .t.5''q G>1 ri--u.10 ,..,,,,„ pi.04.04 Z.11 t4 1 1 t (ti ..z.v 12 ijcosuu.- 14t.ski iLtri 13 K ,,[7 11-L.I.t.1/'1.."14 pit.I.. to Pi 15 VI.../90 1 t (1.-1/1 16 60--..ibly 5yLflt,r.17 K 91,(0 G (('I.1.4.)18 opf.fivi19Lt1 -1..122 20 fit 21 ('PO -zio 22 A/C 23 1 9'1 24 /VC. 25 1 T9 '5-0 26 Ne 27 1 'IY.0 1r3 28 A7 29 30 31 32 .. 33 34 35 36 37 38 39 \40 41 .42 • MAIN:0 6.20 AMP BRK/FUSE 0 MLO Computed Load AMPS BUS:I 255-AMP See Calculation Worksheet on back Branch circuits required: A) Size: No.1/0 B) Type:0 CU Service entrance or feeder conductors:A) Lighting Circuits 220 -3(b), 4(d)DVAL 8) Two Small Appliance Circuits 210 -11(e)C) Insulation:D) Conduit Size:..C) Laundry Circuit 220 -16(b)Service ground/bond:D) Central Heating Equipment 422 -12 A) Size: No.Yi.../B) Type:ErCU 0 AL E) Bathroom 210 -52(d) \C)Clamp location(s): Vill UFER 250 -50(c)Remarks:0 Water Pipe 250 -1040Ground Rod 250 -52 o GFAilocations 210 -8,680 -70:V I certify that all terminations have been torqued in accordance with manufacturer's Bathroom(s) Outdoors ILI Kitchen instructions and that the work shown on this circuit card represents the full extent of Garage(s)0Hydromassage Tub the work performed under this permit.o 0 Owner AFCI Protected Circ. 210 -12 0 Contractor CC- ' "NO Bedroom(s)0 Signed Date F 10--// ..• B-36 Page 1 of 2 Rev. 03/09 SINGLE FAMILY DWELLING ELECTRICAL SERVICE LOAD CALCULATION As an alternative method, the STANDARD METHOD found in ARTICLE 220 of the National Electric Code, may be used 1.GENERAL LIGHTING LOADS Dwelling sq. ft. x 3 VA =220-3(a)VA Small appliance loads —220-16(a) 1500 VA x circuits =VA Laundry load —220-16(b) 1500 VA x circuits ='VA • General Lighting Total VA 2.COOKING EQUIPMENT LOADS —Nameplate Value Range VA =VA Cooktop VA =VA Oven (s)VA =VA Cooking Equipment Total VA 3.ELECTRIC DRYER 220-18 (Nameplate, 5000 VA minimum) Dryer VA =Dryer Total VA 4.FIXED APPLIANCE LOADS 230-30 (b) (3) Dishwasher =VA Disposal =VA Compactor =VA Water Heater =VA Hydromassage Bathtub =VA Microwave Oven =VA Built-in Vacuum =VA VA Fixed Appliance Total VA 5.OPTIONAL SUBTOTAL (Add all of the above totals)VA • 6.APPLYING DEMAND FACTORS —TABLE 220-30 First 10,000 VA x 100% =10,000 VA Optional Subtotal (from line 5) { Remaining VA x 40%VA 7.HEATING OR AC LOAD —TABLE 220-30 Larger of the Heating or AC Load =VA 8.OPTIONAL LOADS TOTAL (Add totals from lines 6 and 7)=VA 9.MINIMUM SERVICE SIZE =Optional Loads Total =Ampere 240 Volt (Please put total on front of card under Computed Load) __ CB152728 2571 STATE ST,\,/4CITY OF STATE ST. TOWNHOMES: PHS.6 B1CARLSBADINSPECTION RECORD 375 SF 1ST FLR COMMERCIAL/1,772 SF LIV/ 444 SFBuilding Division GAR/ 76 SF BALCONY/ 646 SF ROOF DECK INSPECTION RECORD CARD WITH APPROVED RESDNTL CONDO PLANS MUST BE KEPT ON THE JOB Lot#:27 TAYLOR MORRISON OF CA, LLC El CALL BEFORE 1:30 pm FOR NEXT WORK DAY INSPECTION El FOR BUILDING INSPECTION CALL:760-602-2725 OR GO TO: www.Carisbadca.soviBuildfris AND CLICK ON rEcoRD yCopPIr"Request Inspection" DATE:CT--I 0 --ILO Ir -YI 8 IS C 14COKL D BELOW THAT DIVISION'S APPROVAL 15 RI QUIRED PRI, II'.I.:.1.1 -ot Jr •-ilr A I INAL BUR VINO INSPECTION_ IF YOII AVEH ANY UUL.5110N5 PLC.ASE C Al L TI III APPLIC AD!F:DIVISIONS AT THE PHONE Ts/UE.113E1.PF =IVIOF D EL LOW ALTER ALL RF.C:EIPLD APPROVALS ARE:SIGNED or F -FAX TO /60 -602-8560,t MAIL TO ILI I O (I..:'.I:..F I.-I ..I.IO '.I .'..`V OR BRING IN A COPY OF 1E11'.CARD 10:1635 F AR ADAY AVE=..CAR!011.10.CA 92008.BUILDING IN .i.t-i-row:.F AN NI-RLAC IIE_D AT 760-602-2 /00 EIETWI LB 7:30 AM —8:00 AM VHF DAY OF YOUR INSPECTION. NO 103 Required Prior to Requesting Building Final If Checked YES Date Inspector Notes EMIPlanning/Landscape 760-944-8463 Allow48 hours 4 4 1--11 .-yam. NEMCM&I (Engineering inspections(760-438-3891 Call before 2 pm Wain5.6rg.911 1111131 Are Prevention 760-6024660 Allow 48 hours Pi'figit II1.1Ifir/M111 I.VIII 111111111 111111111111.11111 Type of Inspection Type of Inspection Cure 41 BUILDING ::.i c.....$.ELECTRICAL Date Inspector #11 FOUNDATION ?c.- - i.160 if r #31 0 ELECTRIC UNDERGROUND CI MIR #12 REINFORCED STEEL #34 ROUGH ELECTRIC #66 MASONRY PRE GROUT #33 0 ELECTRIC SERVICE 0 TEMPORARY 0 GROUT 0 WALL DRAINS #35 PHOTO VOLTAIC #10 TILT PANELS #39 FINAL #11 POUR STRIPS FYI ..MECHANICAL #11 COLUMN FOOTINGS #41 UNDERGROUND DUCTS &PIPING #14 SUBFRAME 0 FLOOR 0 CEILING #44 0 DUCT&PLENUM 0 REF. PIPING #15 ROOF SHEATHING t1#*Li L MeV-#43 HEAT-AIR COND. SYSTEMS #13 EXT. SHEAR PANELS t .2. 'q #49 FINAL #16 INSULATION c .......:COMBO INSPECTION '#18 EXTERIOR LATH #81 UNDERGROUND (11,12,22,31)... #17 INTERIOR LATH &DRYWALL #82 DIWV/AU.,EXT LATH, GAS TES (17,1.1423)I/3qt 7 ."---- #51 POOL DCA/STEEL/BOND/FENCE #83 ROOFSHEMIN%EXT SHEAR MAD #55 PREPLASTER/FINAL #84 FRAME ROUGH COMBO(10444.44)ffiglIi #2.9 FINAL FINAL #85 T-Bar (104,34,44) IrE .1-PLUMBING Die ..or #89 FINAL OCCUPANCY (19,29,39,49) #22 0 SEWER & BL/C0 0 •CO AIIIIIII FIRE Date In .---r #21 UNDERGROUND °WASTE 0 WTR ,,.0 IV #24 TOP OUT 0 WASTE CI WIN 04/S UNDERGROUND VISUAL #27 TUB &SHOWER PAN A/S UNDERGROUND HYDRO #23 0 GAS TEST 0 GAS PIPING - A/S UNDERGROUND FLUSH #25 WATER HEATER A/SOVERHEAD VISUAL 4#28 SOLAR WATER A/S OVERHEAD HYDROSTATIC #29 FINAL A/S FINAL 931 I.l& 4.17or. cu„:.STORM WATER F/A ROUGH-IN 9 ,, #600 PRE-CONSTRUCTION MEETING F/AFINAL #603 FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN 606 NOTICETO CLEAN FIXED EXNNG SYSTEM HYDROSTATIC TEST #607 WRITTEN WARNING FIXED EXTINGUISHING SYSTEM FINAL #609 NOTICE OF VIOLATION MEDICAL GAS PRESSURE TEST #610 VERBAL WARNING MEDICAL GAS FINAL REV 10/2012 SEE BACK FOR SPECIAL NOTES • INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope —Insulation; Roofing; Fenestration (Page 1 of 3) Site Addrejoimw Enforcement Agency:Permit Number: LOT 2 STREET CB152728 Ifmore than one person has responsibilityfor installation ofthe items on this certificate. each person shall prepare and sign a certificate applicable to the portion ofconstructionfor which they are responsible,. alternatively. the person with chief responsibilityfor construction shall prepare and sign this certificatefor the entire construction.All applicable Mandatory Measures with check boxes require to be checked to ensure the mandatory measures have been met Description of Insulation 1.RAISED FLOOR Material:Brand Name: Thickness (inches):Thermal Resistance (R-Value): §150(d):Minimum R-13 insulation in raised wood-frame floor or equivalent L1-factor, s.2.SLAB FLOOR/PERIMETER Material:__Brand Name: Thickness (inches):N/A Thermal Resistance (R-Value): Perimeter Insulation Depth (inches): §150(1):Water absorption rate for the insulation matenal alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 perm/inch and shall be protected from physical damage and UV light deterioration. 3.EXTERIOR WALL a.Insulation Type (e.it. Batt, Loose Fill, Spray Foam) 2X4 BATTS a.Thermal Resistance (R-Value):R-13 b..Insulation Type (e.x. Ban, Loose Fill, Spray Foam) 1 b.Thermal Resistance (R-Value):R-192X6BAT_TS Brand:MANVILLE Spray/Loose fill)Installed Actual Thickness Spray/Loose fill) (inches):Contractor's min installed weight/ft2 __lb Manufacturer's installed weight per square foot to achieve Thermal Resistance (R-Value) O §I50(c)Minimum R-13 insulation in wood-frame wall or equivalent If-factor Exterior Foam Sheathing (rigid Insulation) Material:Brand Name:_ Thickness (inches)Thermal Resistance (R-Value): 4.FOUNDATION WALL Material:Brand Name: Thickness (inches):N/A Thermal Resistance (R-Value). 5.CEILING Batt or Blanket Type:BLOW Brand Name:MANVILLE Loose Fill Type:_Thermal Resistance (R-Value):R-30 Spray Foam Type:Brand Name: Installed Actual Thickness (inches):_11 1 ______Contractor's min installed weight/ft2 0.432 lb Manufacturer's installed weight per square foot to achieve Thennal Resistance (R-Value): §150(a):Minimum R-19 insulation in wood-frame ceiling or equivalent U factor. 6.ATTIC ROOF INSULATION AND/OR ATTIC RADIANT BARRIER Material:Brand Name: Material:_NiA _Brand Name:_ Thickness (inches):_Thermal Resistance (R-Value): O §118(a):Insulation installed meets Standards for Insulating Material. §150(g):Mandatory Vapor barrier installed in Climate Zones 14 or 16 2008 Residential Compliance Forms August 2009 INSTALLATIONINSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope —Insulation; Roofing; Fenestration (Page 2 of 3) Site Address:Enforcement Agency:Permit Number: LOT 27-2571 STATE STREFT CB152728 Description of Rooting Products — CRRC Product JD Manufacturer Product Roof Roof —Product initialSolar Aged Solar Thermal Number'Information Brand/Model Type Area Slope Weight'Reflectance Reitecunce &Imo= 0' N/AO - 1 CP 1 The CRRC Product ID Aiumbrr can he obtained from the Cool Roof Rating (Mon-it's Rated Product Directory at ww.cuoirouys orgproductssearch.ohp 2 The weight in lbs per square feet ofthe roofing product being ins-lulled 3 Check box if the Aged Reflectance is a calculated value using the equation below footnote 1 4 Ifthe aged reflectance is not available In the Coal Roof Rating Council's Rated Product Directory then use the initialreflectance valuefrom the directory and use the equation (0.2 0,2) to obtatn a calculated aged value CknEoc APPLICABLE BOX BELOW IF' EXEMPT FROM THE ROOFING PRODUCT 'COOL ROOF' REQUIREMENT' O The roofarea covered by building integrated photovoltaic panels and building integrated SOW thermal panels are exempt from the above Cool Roof criteria. O Roof constructions that have thermal mass over the roof membrane with a weight ofat least 25 )b/ft'is exempted from the above Cool Roof criteria. To apply Liquid Field Applied Coatings, the coating must be applied with a minimum dry mil thickness of20 mils across the entire roof surface and meet minimum performance reutrements listed in 6118(ii3 and lobe 118-C Select the applicable cutting 0 Aluminum-Pismented Asphalt Roof Coating 1 0 Cement-based Roof Coating 1 0 Other 0 CRKCt Label Attached to CF-6R (Note ifno CRI?C I label is available, this compliance method cannot be used and another method is required to meet compliance) FENESTRATION/GLAZING Product b 1 oral Quantity Add.Exterior Conroeay Manufacturer/Brand Name (/-Product of NiKC of Like Product Area Shading Dev.t_oeition/ special item KiROur Lik.F NODLIC 'IS)factor)SHGC'Panes r Certified'(Optional)ft2 or Overhang Features 2 4 N/A 1 tsr values drum a fenestration products 4 F RC Certified Label hot-fenestration products without an 4FRC label:an the default values from Section 116. Table I 16-A and 11641 ofthe 20011 Energy 1ffiriency Standards 10.11C Label Certificates shall ntit be removed until the building inspector has verified the efficienc>Enter Yes or .sto fillb(a)1 Doors and windows between conditioned and unconditioned spaces designed to limn air leakage. O ti1 16(a)2 and 3 Actual fenestration products installed are equivalent to or have a lower U factor and/or a lower SHGC than that specified on the Certificate ofCompliance (Form MIR). §I Ib(a)4: Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient (SHGC). and infiltration that meets the requirements of §10-1 11(a) 1:1 *117: Exterior doors and windows weather-stnpped; all Joints and penetrations caulked and sealed. 2008 Residential Compliance harms August 2009 •-_. INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope —Insulation; Roofing; Fenestration (Page 3 of3) Site Address:I Enforcement Agency:Permit Number: LOT 27-2571 STATE STREET CB152728 DECLARATION STATEMENT •I certify under penalty ofperjury, under the laws of the State of California, the information provided on this form is true and correct. •I am eligible under Division 3 of the Business and Professions Code to accept responsibility for construction, or an authorized representative ofthe person responsible for construction (responsible person). •I certify that the installed features. materials. components, or manufactured devices identified on this certificate (the installation) conforms to all applicable codes and regulations, and the installation is consistent with the plans and specifications approved by the enforcement agency •1 reviewed a copy of the Cendicate of Compliance ((T-/R) form approved by the enforcement agency that identifies the specific requirements for the installation.I certify that the requirements detailed on the CF•I R that apply to the inatallatton have been met. •I will ensure that a completed, signed copy of this Instillation Certificate shall be posted. or made available with the building permits)issued for the building, and made available to the enforcement agency for all applicable inspecdons.I understand that a signed copy of this installation Certificate is required to he included with the documentation the builder provides to the building owner at occupancy. Company Naine (Installing Subcontractor or General Contractor or Builder/Owner) ROCKWELL. DRYWALL, INC Responsible Person's Name.Responsible Person's Si t BU1CHINGRAM CSLB License.Date Signed Position With Compa t 956154 1/27/2017 VP OF OPERATIONS 2008 Residential Compliance Forms August 2009 Cantimtaus Inspection Lt.Materials Testing ItOurrinvEsT ................4..........• • • • • • Inspection & Testing, Inc.441 Commercial Way. La Habra. CA 90631 -6168 (562)941 -2990 • (714) 526-8441 FAX (562) 946-0026 December 12, 2016 Building Official City of Carlsbad Department of Building and Safety 1635 Faraday Ave Carlsbad, California 92008 SPECIAL INSPECTOR'S FINAL PROJECT REPORT Project Name:Seagrove Townhomes Address:Tract #CT13-05,PH 6 Building 3 Owner:Taylor Morrison Lot#Address Permit Lot#Address Permit 24 2583 State Street CB152731 28 2567 State Street CB152727 25 2579 State Street CB152730 29 2563 State Street CB152726 26 2575 State Street CB152729 30 2559 State Street CB152725 27 2571 State Street CB152728 This is to certify that Southwest Inspection and Testing, Inc. was employed to perform special inspection on the above mentioned project at the above address, which required continuous inspection per section 1701 of 2013 California Building Code. Brett Alblinger -Reinforced Concrete, Post Tensioned Concrete, ICC #0881693 Bruce Gordon -Reinforced Concrete, Post Tensioned Concrete, ICC #1133732 Based upon special inspection and materials testing written reports of this work, it is our judgment that the inspected work was performed to the best of our knowledge, in accordance with the approved plans, specifications and applicable workmanship provision of the California Building Co•-. nper. c‘ ?'"°4pA. 4r..7'..., ck.WAD.-'I. ,..4...<, r 4.'6%`.•Sincerely,-Reviewed By:etS'...3 ,o., / 1 iii C04/219 mVIcc *Exp...z.....?SP. Cittit .* <....--f:r3..Cifs.Steven L.Goci'6: ---- ey Ian R.Waddell,P.E. President Principal Engineer SLG/IRW: amc For inspection and testing only. no design responsibility expressed or implied.