Loading...
HomeMy WebLinkAbout2573 STATE ST; ; CB152712; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 02-18-2016 Residential Permit Permit No: CB152712 Building Inspection Request Line (760) 602-2725 Job Address:2573 STATE ST CBAD Permit Type:RESDNTL Sub Type: CONDO Status: ISSUED Parcel No:2030543414 Lot #:14 Applied: 08/20/2015 Valuation:$295,759.00 Constuction Type: 5B Entered By: JMA Occupancy Group:Reference #: CT130005 Plan Approved: 02/18/2016 # Dwelling Units:1 Structure Type: MF5+Issued: 02/18/2016 Bedrooms:0 Bathrooms:0 Inspect Area: PY Orig PC #:PC140037 Plan Check #: PC150047 Project Title:STATE ST. TOWNHOMES: PHS 5 C1 405 SF 1ST FLR COMMERCIAL/1,694 SF LIV/ 476 SF GAR/ 67 SF BALCONY/ 585 SF ROOF DECK Applicant:Owner: TAYLOR MORRISON OF CA, LLC STE 1450 100 SPECTRUM DR IRVINE CA 92618-4935 949-341-1289 Building Permit $1,317.94 Meter Size FS1 Add' Building Permit Fee $0.00 Add'I Red. Water Con. Fee $0.00 Plan Check $922.56 Meter Fee $317.00 Add'I Plan Check Fee ($500.00)SDCWA Fee $4,800.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $38.45 PFF (3105540)$5,382.81 Park in Lieu Fee $6,190.00 PFF (4305540)$4,968.75 Park Fee $0.00 License Tax (3104193)$0.00 LFM Fee $0.00 License Tax (4304193)$0.00 Bridge Fee $0.00 Traffic Impact Fee (3105541)$0.00 Other Bridge Fee $0.00 Traffic Impact Fee (4305541)$0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BTD #3 Fee $0.00 PLUMBING TOTAL $210.00 Renewal Fee $0.00 ELECTRICAL TOTAL $89.00 Add'I Renewal Fee $0.00 MECHANICAL TOTAL $65.38 Other Building Fee $0.00 Housing Impact Fee $0.00 HMP Fee $0.00 Housing InLieu Fee $0.00 Pot. Water Con. Fee $3,931.00 Housing Credit Fee $0.00 Meter Size FS1 Master Drainage Fee $0.00 Add'I Pot. Water Con. Fee $3.00 Sewer Fee $881.00 Recl. Water Con. Fee $0.00 Additional Fees $202.00 Green Bldg Stands (SB1473) Fee $12.00 Fire Sprinkler Fees $0.00 Green Bldg Stands Plan Chk Fee $0.00 TOTAL PERMIT FEES $28,830.89 Total Fees:$28,830.89 Total Payments to Date:$28,830.89 Balance Due:$0.00 FINAL AP Inspector:Date:1.41/Clearance: NOTICE:Please take approval of your project indudes the"Irrpositi "of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exacti ."You have 90 days from the date this permit was issued to protest imposition of these fees/exactions.If you protest tilt:1114w trust fcilow the protest procedures set forth in Governmentrate Section 66020(a), and file the protest and any other required information with the Qty Manager for processing in accordance with Carlsbad Municipal rride Section 3.32030.Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their inuusition. You are hereby FURTFER NOTIFIED that your rip to protest the specified fees/exactions DOES NOT APPLY to water and sewocnnection fees and capacity changes, nor planning, zoning,gatingor other similar application processing or service fees in connection with this project.NOR DOES IT APPLY to any fees/exactions of which VW have Previously been Mn a NOTICE similar to this. or as to which the statute of limitations hasicreviouslv otherwise expired. •."•••••PERMIT INSPECTION. HISTORY'REPORT (CBI52712)..„...„.:..•.......,...•. Permit Type:BLDG-Residential Application Date:08/20/2015 Owner: Work Class:Condo Issue Date:02/18/2016 Subdivision: Status:Closed -Finaled Expiration Date:09/01/2017 Address:2573 State St Carlsbad, CA IVR Number:708718 Scheduled Actual Date Start Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete 11/09/2016 11/09/2016 BLDG-15 000385-2016 Passed Paul York Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 11/21/2016 11/21/2016 BLDG-13 Shear 002037-2016 Failed-Construction Paul York Reinspection Complete Panels/HD (ok to Change Needed wrap) Checklist item COMMENTS Passed BLDG-Building Deficiency No 11/28/2016 11/28/2016 BLDG-13 Shear 002923-2016 Failed Paul Burnette Reinspection Complete Panels/HD (ok to wrap) Checklist !tern COMMENTS Passed BLDG-Building Deficiency No 11/30/2016 11/30/2016 BLDG-13 Shear 003498-2016 Failed-Construction Paul York Reinspection Complete Panels/HD (ok to Change Needed wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 12/01/2016 12/01/2016 BLDG-13 Shear 003754-2016 Passed Paul York Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 12/22/2016 12/21/2016 BLDG-84 Rough 006460-2016 Failed-Construction Paul York Reinspection Complete Combo(14,24,34,44)Change Needed Checklist Item COMMENT'S Passed BLDG-Building Deficiency No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 01/04/2017 01/04/2017 BLDG-17 Interior 008116-2017 Passed Paul York Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-23 008117-2017 Passed Paul York Complete Gas/Test/Repairs —— April 04, 2017 Page"1 of 2 ,• . •...••••........... ,.'••PERMIT INSPECTION: HISTORY.REPORTICB1527.12y..PERMIT:;... Permit Type:BLDG-Residential Application Date:08/20/2015 Owner Work Class:Condo Issue Date:02/18/2016 Subdivision: Status:Closed -Finaled Expiration Date:09/01/2017 Address:2573 State St Carlsbad, CA IVR Number:708718 Scheduled Actual Date Start Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency No 01/09/2017 01/09/2017 BLDG-18 Exterior 008799-2017 Passed Paul York Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No 02/23/2017 02/23/2017 BLDG-Electric Meter 014419-2017 Failed-Construction Paul York Reinspection Complete Release Change Needed Checklist Item COMMENTS Passed BLDG-Building Deficiency No 02/28/2017 02/28/2017 BLDG-Electric Meter 014841-2017 Passed Paul York Complete Release Checklist Item COMMENTS Passed BLDG-Building Deficiency No 03/20/2017 BLDG-Fire Final 017245-2017 Scheduled Dominic Fieri Incomplete Checklist Item COMMENTS Passed FIRE-Building Final No 04/04/2017 04/04/2017 BLDG-Final 018753-2017 Passed Paul York Complete Inspection Checklist item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes Page 2 of 2April04, 2017 Inspection List Permit#:CB152712 Type:RESDNTL CONDO STATE ST. TOWNHOMES: PHS 5 C1 405 SF 1ST FLR COMMERCIAL/1,694 SF L Date Inspection Item Inspector Act Comments 11/01/2016 17 Interior Lath/Drywall PY PA 10/27/2016 15 Roof/Reroof PD PA 10/11/2016 17 Interior Lath/Drywall PD PA • 09/21/2016 17 Interior Lath/Drywall PY PA 08/29/2016 11 Ftg/Foundation/Piers PY AP 08/12/2016 21 Underground/Under Floor PY AP 08/11/2016 21 Underground/Under Floor PY AP 08/11/2016 22 Sewer/Water Service PY AP Wednesday, April 05, 2017 Page 1 of 1 Crattitulort‘hvie(Afitteriah TevtingItsourrury mspr • • • • • • • •46..• • • • •Ab. Inspection & Testing,Inc.441 Commercial Way. La Habra, CA 90631 -6168 (562) 941 -299(1 • (714) 526-8441 FAX (562) 946-0026 December 12, 2016 Building Official City of Carlsbad Department of Building and Safety 1635 Faraday Ave Carlsbad, California 92008 SPECIAL INSPECTOR'S FINAL PROJECT REPORT Project Name:Seagrove Townhomes Address:Tract #CT13-05,PH 5 Building 2 Owner:Taylor Morrison Lot#Address Permit Lot#Address Permit 10 2557 State Street CB152706 14 2573 State Street CB152712 11 2561 State Street CB152709 15 2577 State Street CB152713 12 2565 State Street CB152710 16 2581 State Street CB152714 13 2569 State Street CB152711 17 2585 State Street CB152707 This is to certify that Southwest Inspection and Testing, Inc. was employed to perform special inspection on the above mentioned project at the above address, which required continuous inspection per section 1701 of 2013 California Building Code. Brett Alblinger -Reinforced Concrete, Post Tensioned Concrete, ICC #0881693 Bruce Gordon -Reinforced Concrete, Post Tensioned Concrete, ICC #1133732 Larry E Robertson -Reinforced Concrete, Post Tensioned Concrete, ICC #5090690 Based upon special inspection and materials testing written reports of this work, it is our judgment that the inspected work was performed to the best of our knowledge, in accordance with the approved plans, specifications and applicable workmanship provision of the California Building Code. 9.i\CIFE Sincere.Reviewed By: (,)*)'?.704/47,(- 0041219 m.\Exp 345 e a3 N.....C:1111k.4•Steven L.Go#bey Ian R.Waddell,P.E.QF rAuf •"'I. President Principal Engineer SLG/IRW: amc For inspection and testing only. no design responsibility expressed or implied. '.... .•'•,..', tcrik STATE ST. TOWNHOMES: PHS 5Ne CB152712 2573 STATEcSiT ccre oe •CARLSBAD INSPECTION RECORDuilding Division 405 SF671SsTF FB LA LRcCoONMyr58R5Cs1 AFL R/10. 6094F S F DECKL IV /476 SF RESDNTL CONDO INSPECTION RECORD CARD WITH APPROVED Lot#14 TAYLOR MORRISON OF CA. LLC PLANS MUST BE KEPT ON THE JOB El CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION •0 FOR BUILDING INSPECTION CALL:760-602-2725 OR GO TO: www.Carlsbadca.aov/Buildinq AND CLICK ON •"Reque lnsp !on"•DATE:A I '-- _.. IF ''YES"IS CHECKED BELOW THAT DIVISION'S APPROVAL IS REQUIRED PRIOR TO REQUESTING. A FINAL BUILDING INSPECTION. :•'IF YOU HAVE ANY QUESTIONS PLEASE CALL THE APPLICABLE DIVISIONS AT THE PHONE NUMBERS PROVIDED BELOW.AFTER •OFF-FAX TO 760-602-8560.EMAIL TO ALLREQUIREDAPPROVALS ARE SIGNED ElLooiNsFADCA.GOV OR BRING IN A COPY OF THIS CARD TO:1635 FARADAY AVE.. CARLSBAD. CA 92008.BUILDING INSPECTORS CAN BE REACHED •AT 760-602-2700 BETWEEN 7:30 AM -8:00 AM THE DAY OF YOUR INSPECTION. Notes NO YES Required Prior to Requesting Building Final If Checked YES Date Inspector Nyr Planning/Landscape 760-944-8463 Allow 48 hours ..rt (AV .'Awe" CM&I lEngIneering Inspections)760-438-3891 Call before 2 pm IWZ:Allillialtir4 3 1..n sipc14.17 -.....,.. ,_...y Fire Prevention 760-602-4660 Allow 48 hours ..._ Type of Inspection Type of Inspection coot .BUILDING Da Inspec •r coos #ELECTRICAL Date Inspector #11 FOUNDATION X £B/I•ii."r"#31 0 ELECTRIC UNDERGROUND 0 UFER ,.#12 REINFORCED STEEL #34 ROUGH ELECTRIC 66 MASONRY PRE GROUT•#33 0 ELECTRIC SERVICE 0 TEMPORARY _0 GROUT 0WALL DRAINS #35 PHOTO VOLTAIC #10 TILT PANELS #39 FINAL #11 POUR STRIPS cone 0 MECHANICAL #11 COLUMN FOOTINGS #41 UNDERGROUND DUCTS&PIPING #14 SUBFRAME 0 FLOOR 0 CEILING . _#44 0 DUCT&PLENUM 0 REF. PIPING #15 ROOF SHEATHING idio 4 )/..."------- #43 HEAT-AIR COND. SYSTEMS #13 EXT. SHEAR PANELS /2 /4 Al/N49 FINAL #16 INSULATION Cot:W.#COMBO INSPECTION ,.#18 EXTERIOR LATH -/1 #81 UNDERGROUND (11,12,21,31) #17 INTERIOR LATH &DRYWALL i .:4 17 #82 DRYWALLEXT LATH, GAS TES (17,18,23) #51 POOL ECCA/STEEL/BOND/FENCE #83 ROOF SHEATING, EXT SHEAR(13,15) #55 PREPIASTER/FINAL #84 FRAME ROUGH COMBO (14,24,34,44)/....744.l„,,../- #19 FINAL #85 T-Bar (14.24,34,44)... --,Date In ector #89 FINAL OCCUPANCY (19,2949,49) #22 0 SEWER & BL/CO 0 PL/CO #21 UNDERGROUND °WASTE 0 WM /Date Inspector #24 TOP OUT 0WASTE 0 WTFt A/S UNDERGROUND VISUAL 7 #27 TUB &SHOWER PAN A/S UNDERGROUND HYDRO - #23 TEST 0 GAS PIPING /3//7 b A/S UNDERGROUND FLUSH #25 W R HEATER _A/S OVERHEAD VISUAL . #28 SOLAR WATER A/S OVERHEAD HYDROSTATIC #29 FINAL e4E. ---m,A/SFINAL eak4'000##STORM WATER F/AROUGH-IN #600 PRE-CONSTRUCTION MEETING F/AFINAL, FOLLOW UP INSPECTION \\A-1 Ved•AP---j #603 FO FIXED EXTINGUISHING SYSTEM ROUGH-IN 5 NOTICETO CLEAN _FIXED EXTING SYSTEM HYDROSTATIC TEST WRITTEN WARNING ' 607 FIXED EXTINGUISHING SYSTEM FINAL #609 NOTICE OF VIOLATION MEDICAL GAS PRESSURE TEST . • #610 VERBAL WARNING MEDICAL GAS FINAL REV 10/1012 SEE BACK FOR SPECIAL NOTES • . ..•,,,. ,•.-..-' BLDG 2 INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope —Insulation; Roofing; Fenestration (Page 1 of 3) Site Address:Enforcement Agency:Permit Number: LOT 14-2573 STATE STREET.CB152712 Ifmore than one person has responsibilityfor installation ofthe items on this certificate, each person shall prepare and sign a certificate applicable to the portion ofconstructionfor which they are responsible; alternatively, the person with chief responsibilityfor construction shall prepare and sign this certificatefor the entire construction.Allapplicable Mandatory Measures with check boxes require to be checked to ensure the mandatory measures have been met. Description of Insulation 1.RAISED FLOOR Material:Brand Name: Thickness (inches):N/A Thermal Resistance (R-Value): §150(d):Minimum R-I3 insulation in raised wood-frame floor or equivalent U-factor. 2.SLAB FLOOR/PERIMETER Material:Brand Name: Thickness (inches):N/A Thermal Resistance (R-Value): Perimeter Insulation Depth (inches): §150(1):Water absorption rate for the insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 perm/inch and shall be protected from physical damage and UV light deterioration. 3.EXTERIOR WALL a.Insulation Type (e.x. Batt, Loose Fill, Spray Foam) 2X4 BATTS a.Thermal Resistance (R-Value):R-13 b..Insulation Type (e.x. Batt, Loose Fill, Spray Foam)b.Thermal Resistance (R-Value):R-192X6 BATTS Brand:MANVILLE Spray/Loose fill)Installed Actual Thickness Spray/Loose fill) (inches):Contractor's min installed weight/t12 lb Manufacturer's installed weight per square foot to achieve Thermal Resistance (R-Value) §150(c):Minimum R-13 insulation in wood-frame wall or equivalent U-factor. Exterior Foam Sheathing (rigid Insulation) Material:Brand Name: Thickness (inches):N/A Thermal Resistance (R-Value): 4.FOUNDATION WALL Material:Brand Name: Thickness (inches):N/A Thermal Resistance (R-Value): 5.CEILING Batt or Blanket Type:BATTS Brand Name:MANVILLE Loose Fill Type:Thermal Resistance (R-Value):R-30 Spray Foam Type:Brand Name: Installed Actual Thickness (inches):Contractor's min installed weight/ft2 lb Manufacturer's installed weight per square foot to achieve Thermal Resistance (R-Value): O §150(a): Minimum R-19 insulation in wood-frame ceiling or equivalent U-factor. 6.ATTIC ROOF INSULATION AND/OR ATTIC RADIANT BARRIER Material:Brand Name: Material:N/A Brand Name: Thickness (inches):Thermal Resistance (R-Value): O §118(a):Insulation installed meets Standards for Insulating Material. §150(g):Mandatory Vapor barrier installed in Climate Zones 14 or 16. 2008 Residential Compliance Forms August 1009 RI DG 2 INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope —Insulation; Roofing; Fenestration (Page 2 of3) Site Address:Enforcement Agency:Permit Number: LOT 14-2573 STATE STREET CB152712 Description of Roofing Products CRRC Product ID Manufacturer Product Roof Roof Product Initial Solar Aged Solar Thermal Number'Information Brand/Model Type Area Slope Weight2 Reflectance Reflectance'Emittance 0' N/A •Os 1.The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Product Directory at ww.coolroofs.org/products/search.php 2.The weight in lbs per square feet ofthe roofing product being installed 3.Check box ifthe Aged Reflectance is a calculated value using the equation below, footnote 4. 4.Ifthe aged reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the initial reflectance value from the directory and use the equation (0.2+ 0.7(pmwai -0.2) to obtain a calculated aged value. riCHECKAPPLICABLE BOX BELOWIFEXEMPT FROM THE ROOFING PRODUCT "COOL ROOF" REQUIREMENT: O The roofarea covered by building integrated photovoltaic panels and building integrated solar thermal panels are exempt from the above Cool Roof criteria. O Roof constructions that have thermal mass over the roof membrane with a weight of at least 25 lb/fit is exempted from the above Cool Roof criteria. To apply Liquid Field Applied Coatings, the coating mum be applied with a minimum dry mil thickness of20 mils across the entire roofsurface and meet minimum performance requirements listed in §11813 and Table 118-C.Select the applicable coating Aluminum-Pigmented Asphalt Roof Coating 1 0 Cement-Based Roof Coating 1 Other CRRC-1 Label Attached to CF-6R (Note ifno CRRC-1 label is available, this compliance method cannot be used and another method is required to meet compliance). FENESTRATION/GLAZING Product 4 Total Quantity Add. Exterior Comments/ Manufacturer/Brand Name U-Product of NFRC of Like Product Area Shading Deli.Location/ Special Item (GROUP LIKE RODUCTS)factor'SHGC'Panes Certified"(Optional)ft2 or Overhang Features 2 3 N/A 5 6 7. 8. I.Use valuesfrom afenestration product's NFRC Certified Label. For fenestration products without an NFRC !obeli use the default values from Section 116.Table 116-A and 116-13ofthe 2008 Energy Efficiency Standards. 2. NFRC Label Certificates shall not be removed until the building inspector has verified the efficiency. Enter Yes or No. O §116(a)1: Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. §116(a)2 and 3: Actual fenestration products installed are equivalent to or have a lower U-factor and/or a lower SHGC than that specified on the Certificate ofCompliance (Form CF-1R). §116(a)4: Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration that meets the requirementsof §10-111(a) §117:Exterior doors and windows weather-stripped; all joints and penetrations caulked and sealed. 2008 Residential Compliance Forms August 2009 BLDG 2 INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope —Insulation; Roofing; Fenestration (Page 3 of3) Site Address:Enforcement Agency:Permit Number: LOT 14-2573 STATE STREET CB152712 DECLARATION STATEMENT •I certify under penalty ofperjury, under the laws of the State of California. the information provided on this form is true and correct. •1 sin eligible under Division 3 of the Business and Professions Code to accept responsibility for construction, or an authorized representative ofthe person responsible for construction (responsible person). •I certify that the installed features, materials, components, or manufactured devices identified on this certificate (the installation) conforms to all applicable codes and regulations, and the installation is consistent with the plans and specifications approved by the enforcement agency. •I reviewed a copy ofthe Certificate ofCompliance (CF-1R) form approved by the enforcement agency that identifies the specific requirements for the installation.I certify that the requirements detailed on the CF-IR that apply to the installation have been met. •1 will ensure that a completed, signed copy of this Installation Certificate shall be posted, or made available with the building permits)issued for the building, and made available to the enforcement agency for all applicable inspections.I understand that a signed copy of this Installation Certificate is required to be included with the documentation the builder provides to the building owner at occupancy. Company Name:(Installing Subcontractor or General Contractor or Builder/Owner) ROCKWELL DRYWALL, INC. Responsible Person's Name:Responsible Person's Sigtd?.griBUTCH INGRAM CSLB License:Date Signed:Position With Company (Title): 956154 1/10/2017 VP OF OPERATIONS 2008 Residential Compliance Forms August 2009 Is .2 7 /2.— Development Services(City of CIRCUIT CARD Building Division Carlsbad B -36 •.1635 Faraday Avenue " . 760-602-2719 www.carlsbadca.gov Lb -fr i Li THIS CARD MUST BE FILLED OUT AND AVAILABLE AT THE SERVICE EQUIPMENT FOR THE ROUGH INSPECTION Address:'(is .-.24 .e...-.)\---0A--Permit Number: Owner:Phone:Area in Sq.Ft.Contractor:Phone: PANEL:A.I.C.(LO VOLTS 24-40 0 0 WIRE BKR WIRE WIRE BKRLOCATIONCKTMISCRECRECLTGMISC CKT LOCATIONSIZESIZETYPESIZETYPESIZE '" I rt.luit 1 i )114 00 i I VI-iSkklA I.)40 2 it;6.1...c. G...--vi.3 6-tt't t %Vt..iv 4 .N .6r( 9011.(et.5 IP a q i 14 t C 6 Clew 1.5P t- Oufu.IX2 7 15 kiA Ltd ')-I \-t..L c 8 p54041-4 - ital< bi.9 •t<tL/1 (9 'L-t1.-W 10 /et E .t/p... 14k.'ck.11 vs-0 %I (.r/1-2-a 12 Ltic_a2L IVI.13 (*;..tt ct 5-•t I.- 1 -1. 4'14 1-(C IAit itp0 15 t 5- VA l 3 t (1-1.4 16 Afe„. Liorst..t^17 CS,tt'IN (,q -v0 \/2c 18 ,Ve. t*tat vo.19 t ''.(tii NV 10 '5 (ki)-7.c-20 Ale. 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 \40 41 42 • MAIN:0 IX°AMP BRK/FUSE CI MLO Computed Load AMPS BUS:AMP See Calculation Worksheet on back Service entrance or feeder conductors: A) Size: No.VC B) Type:0 CU Er Branch circuits required: A) LightingCircuits 220 -3(b),4(d)AL B) Two Small Appliance Circuits 210 -11(e) C) Insulation:D) Conduit Size:C) Laundry Circuit 220 -16(b)Service ground/bond:,D) Central Heating Equipment 422 -12 A) Size: No.V 0 B) Type:[(CU 0 AL E) Bathroom 210 -52(d) C) Clamp location(s): nal UFER 250 -50(c)Remarks:0 Water Pipe 250 -1040Ground Rod 250 -52 0 GFCI locations 210 -8, 680 -70:,I certify that all terminations have been torqued in accordance with manufacturer's N•El Bathroom(s)NO Kitchen instructions and that the work shown on this circuit card represents the full extent of-- TLI Garage(s)OHydromassage Tub the work performed under this permit. N Outdoors o o Owner AFCI Protected Circ. 210 -12 0 Contractor .11/.e.• 61Bedroom(s)0 Signed Date / Z -/Th777/4— ".• B-36 Page 1 of 2 Rev. 03/09 SINGLE FAMILY DWELLING ELECTRICAL SERVICE LOAD CALCULATION As an alternative method, the STANDARD METHOD found in ARTICLE 220 of the National Electric Code, may be used 1.GENERAL LIGHTING LOADS Dwelling sq. ft. x 3 VA =220-3(a)VA Small appliance loads —220-16(a) 1500 VA x circuits =VA Laundry load —220-16(b) 1500 VA x circuits ='VA General Lighting Total VA 2.COOKING EQUIPMENT LOADS —Nameplate Value Range VA =VA Cooktop VA =VA Oven (s)VA =VA Cooking Equipment Total VA 3.ELECTRIC DRYER 220-18 (Nameplate, 5000 VA minimum) Dryer VA =Dryer Total VA 4.FIXED APPLIANCE LOADS 230-30 (b) (3) Dishwasher =VA Disposal =VA Compactor =VA Water Heater =VA Hydromassage Bathtub =VA Microwave Oven =VA Built-in Vacuum =VA VA Fixed Appliance Total VA 5.OPTIONAL SUBTOTAL (Add all of the above totals)VA 6.APPLYING DEMAND FACTORS —TABLE 220-30 First 10,000 VA x 100%=10,000 VA Optional Subtotal (from line 5) { Remaining VA x 40%=VA 7.HEATING OR AC LOAD -TABLE 220-30 Larger of the Heating or AC Load =VA 8.OPTIONAL LOADS TOTAL (Add totals from lines 6 and 7)=VA 9.MINIMUM SERVICE SIZE =Optional Loads Total =Ampere 240 Volt (Please put total on front of card under Computed Load)