HomeMy WebLinkAbout2575 STATE ST; ; CB152729; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
02-18-2016 Residential Permit Permit No: CB152729
Building Inspection Request Line (760) 602-2725
Job Address:2575 STATE ST CBAD
Permit Type:RESDNTL Sub Type: CONDO Status: ISSUED
Parcel No:2030543426 Lot #:26 Applied: 08/21/2015
Valuation:$301,913.00 Constuction Type: 5B Entered By: JMA
Occupancy Group:Reference #: CT130005 Plan Approved: 02/18/2016
# Dwelling Units:1 Structure Type: MF5+issued: 02/18/2016
Bedrooms:0 Bathrooms:0 Inspect Area: PY
Orig PC #: PC140037 Plan Check #: PC150048
Project Title:STATE ST. TOWNHOMES: PHS.6 B1
375 SF 1ST FLR COMMERCIAL/1,772 SF UV/ 444 SF GAR/ 76 SF
BALCONY/ 646 SF ROOF DECK
Applicant:Owner:
TAYLOR MORRISON OF CA, LLC
STE 1450
100 SPECTRUM DR
IRVINE CA 92618-4935
949-341-1289
Building Permit $1,339.12 Meter Size FS1
Add'I Building Permit Fee $0.00 Add'I Recl. Water Con. Fee $0.00
Plan Check $937.38 Meter Fee $317.00
Add'I Plan Check Fee ($500.00)SDCWA Fee $4,800.00
Plan Check Discount $0.00 CFD Payoff Fee $0.00
Strong Motion Fee $39.25 PFF (3105540)$5,494.82
Park in Lieu Fee $6,190.00 PFF (4305540)$5,072.14
Park Fee $0.00 License Tax (3104193)$0.00
LFM Fee $0.00 License Tax (4304193)$0.00
Bridge Fee $0.00 Traffic Impact Fee (3105541)$0.00
Other Bridge Fee $0.00 Traffic Impact Fee (4305541)$0.00
BTD #2 Fee $0.00 Sidewalk Fee $0.00
BTD #3 Fee $0.00 PLUMBING TOTAL $210.00
Renewal Fee $0.00 ELECTRICAL TOTAL $89.00
Add'I Renewal Fee $0.00 MECHANICAL TOTAL $65.38
Other Building Fee $0.00 Housing Impact Fee $0.00
HMP Fee $0.00 Housing InLieu Fee $0.00
Pot. Water Con. Fee $3,931.00 Housing Credit Fee $0.00
Meter Size FS1 Master Drainage Fee $0.00
Add'I Pot. Water Con. Fee $3.00 Sewer Fee $881.00
Red. Water Con. Fee $0.00 Additional Fees $202.00
Green Bldg Stands (SB1473) Fee $13.00 Fire Sprinkler Fees $0.00
Green Bldg Stands Plan Chk Fee $0.00
TOTAL PERMIT FEES $29,084.09
Total Fees:$29,084.09 otal Payments to Date:$29,084.09 Balance Due:$0.00
FINAL A""RQVAL,
Inspector:6 Date:/Ze.)/Clearance:
4 INOTICE:Please take 01 CE approval of your on:30d includes the "I on ci f ,dedications rwrvations, or other exactions hereafter collectively
referred to as "fees/exacti have 90 days from the date thisremit was issuedto est impositioncithese fees/exacticns.If you protest them, you must
fdlavthe protest • •-•set •in Government Cade Section 66020(a), and file the protest and any other required information with the City Manager for
processing in aociondare th Carlsbad Mxudpal Cat"Section 3.32.030.Failure to timelyfdlow that procedure vull bar any subseaent legal action to attack,
review, set aside, void, or annul their imposition.
You we hereby FU211-ER NOTIFIED that your right to protest the specified fees/exadicns DOES NOT APPLY to wateraid sewer connection fees and cepaOty
changes, nor planting, zoning, gracing or other similar application processing or service fees in connection with this project.NOR DOES IT APPLY to any
feeslexadions of Mich you have Previously been riven a NOTICE similar to this. or as to Which the statute of limitations haureviously otherwise expired.
PERMIT INSPECTION HISTORY REPORT (CB152729)
Permit Type:BLDG-Residential Application Date:08/21/2015 Owner:
Work Class:Condo Issue Date:02/18/2016 Subdivision:
Status:Closed -Finaled Expiration Date:07/31/2017 Address:2575 State St
Carlsbad, CA
IVR Number:708755
Scheduled Actual Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete
Date Start Date
11/14/2016 BLDG-15 002295-2016 Passed Paul York Complete
Roof/ReRoof (Patio)
11/10/2016 11/10/2016 BLDG-15 000574-2016 Partial Pass Paul York Reinspection Incomplete
Roof/ReRoof (Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
11/17/2016 11/17/2016 BLDG-17 Interior 001365-2016 Partial Pass Paul York Reinspection Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
12/14/2016 12/14/2016 BLDG-13 Shear 005384-2016 Passed Paul York Complete
Panels/HD (ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
01/19/2017 01/19/2017 BLDG-84 Rough 010129-2017 Passed Paul York Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-14 No
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout No
BLDG-34 Rough Electrical No
BLDG-44 No
Rough-Ducts-Dampers
01/26/2017 01/26/2017 BLDG-17 Interior 011294-2017 Passed Paul York Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-23 011295-2017 Passed Paul York Complete
Gas/Test/Repairs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
01/30/2017 01/30/2017 BLDG-18 Exterior 011760-2017 Passed Paul York Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
April 13, 2017 Page 1 of 2
PERMIT INSPECTION HISTORY REPORT (CE31 S2729)
Permit Type:BLDG-Residential Application Date:08/21/2015 Owner:
Work Class:Condo Issue Date:02/18/2016 Subdivision:
Status:Closed -Finaled Expiration Date:07/31/2017 Address:2575 State St
Carlsbad, CA
!YR Number:708755
Scheduled Actual
Date Start Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete
03/14/2017 03/14/2017 BLDG-Electric Meter 016377-2017 Passed Paul York Complete
Release
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
04/06/2017 04/06/2017 BLDG-Fire Final 018885-2017 Passed Dominic Fieri Complete
Checklist Item COMMENTS Passed
FIRE-Building Final Yes
04/13/2017 04/13/2017 BLDG-Final 019850-2017 Passed Paul York Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
April 13, 2017 Page 2 of2
Inspection List
Permit#:CB152729 Type:RESDNTL CONDO STATE ST. TOWNHOMES: PHS.6 B1
375 SF 1ST FLR COMMERCIAU1,772 SF L
Date Inspection Item Inspector Act Comments
10/12/2016 17 Interior Lath/Drywall PD PA
09/28/2016 17 Interior Lath/Drywall PY PA
09/06/2016 11 Ftg/Foundation/Piers PY AP
08/10/2016 21 Underground/Under Floor PY AP
08/10/2016 22 Sewer/Water Service PY AP
Thursday, April 20, 2017 Page 1 of 1
r.Development ServicesCity of CIRCUIT CARD Building Division
Carlsbad B -36 •.1635 Faraday Avenue '
.
760-602-2719
www.carlsbadca.gov
THIS CARD MUST BE FILLED OUT AND AVAILABLE AT THE SERVICE EQUIPMENT FOR THE ROUGH INSPECTION
Address:/575"Permit Number:
Owner:Phone:Area in Sq. Ft.
Contractor:Phone:
PANEL;1300 11(A.I.C.4716;p_VOLTS Za.-0 0 yV WIRE
BKR WIRE WIRE BKRLOCATIONCKTMISCRECRECLTGMISC CKT LOCATIONSIZESIZETYPESIZETYPESIZE
f74.411 CIf I 1 1-it.
)1)
4 (II'C
/U
6"
--
2 6 rt &el
)&0--cif(3 2O (A t.t.4 el{.
.
Kii-;PL 5 20 11.
.ot
yk.
6 tru/reeck
c
ers
Iyuc12 7 1.19 it.I %8 el iyappi
A/C.9 •20 (1.1 $110 #440-e ee/5/4i e3
A/11 •1/9 k1.I t 1 Et 12
Doge. Or
X,
A/C 13 3 °(00 1 1.-(1.-14 gc.44-1
A/c„.15 5 0 i 0 1I--0(0 16 pg /9*./
126111./(44 it"17 t c I LI i _Ct 1 18 glA /4
&Ale hi.19 (5.-kg i ii f0 i/V 20 / it...-
evi-Cd•21 /L7 (I.I 22
Lic.st.....23 "LA)tt...t 24
25 26
27 28
29 30
31 32
._.
33 34
35 36
37 38
39 \40
41 .42
•
.,../90MAIN:0 b•f-AMP BRK/FUSE 0 MLO Computed Load AMPS
BUS:(-1"---
AMP See Calculation Worksheet on back
Branch circuits required:Service entrance or feeder conductors:A) Lighting Circuits 220 -3(b), 4(d)A) Size: No.r0 B) Type:0 CU AL B) Two Small Appliance Circuits 210 -11(e)
C) Insulation:D) Conduit Size:C) Laundry Circuit 220 -16(b)
Service ground/bond:D) Central Heating Equipment 422 -12
A) Size: No./0 8)Type CU 0 AL E) Bathroom 210 -52(d)
.,C) Clamp locati n(s):
NI UFER 250 -50(c)Remarks:0 Water Pipe 250 -104
0 Ground Rod 250 -52
0
G CI locations 210-8, 680 -70:I certify that all terminations have been torqued in accordance with manufacturer's"El Bathroom(s)NI Kitchen instructions and that the work shown on this circuit card represents the full extent of
\hE Garage(s)OHydromassage Tub the work performed under this permit.'Outdoors 0 a OwnerACIProtected Circ. 210 -12 0 ContractortiAfrek
-kf Cc=
‘Rt.Bedroom(s)0 Signed ----r-71---Date 1.-/0-Ter7
..
13-36 Page 1 of 2 Rev. 03/09
SINGLE FAMILY DWELLING
ELECTRICAL SERVICE LOAD CALCULATION
As an alternative method, the STANDARD METHOD
found in ARTICLE 220 of the National Electric Code, may be used
1.GENERAL LIGHTING LOADS
Dwelling sq. ft. x 3 VA =220-3(a)VA
Small appliance loads —220-16(a) 1500 VA x circuits =VA
Laundry load —220-16(b)1500 VA x circuits ='VA •
General Lighting Total VA
2.COOKING EQUIPMENT LOADS —Nameplate Value
Range VA =VA
Cooktop VA =VA
Oven (s)VA =VA
Cooking Equipment Total VA
3.ELECTRIC DRYER 220-18 (Nameplate, 5000 VA minimum)
Dryer VA =Dryer Total VA
4.FIXED APPLIANCE LOADS 230-30 (b) (3)
Dishwasher =VA
Disposal =VA
Compactor =VA
Water Heater =VA
Hydromassage Bathtub =VA
Microwave Oven =VA
Built-in Vacuum =VA
VA
Fixed Appliance Total VA
5.OPTIONAL SUBTOTAL (Add all of the above totals)VA
6.APPLYING DEMAND FACTORS —TABLE 220-30
First 10,000 VA x 100%=10,000 VA
Optional Subtotal (from line 5) { Remaining VA x 40%=VA
7.HEATING OR AC LOAD —TABLE 220-30
Larger of the Heating or AC Load =VA
8.OPTIONAL LOADS TOTAL (Add totals from lines 6 and 7)=VA
9.MINIMUM SERVICE SIZE =Optional Loads Total =Ampere
240 Volt
(Please put total on front of card under Computed Load)
•
CB152729 2575 STATE ST
'•:":"F;CITY OF STATE ST. TOWNHOMES: PHS.6 B1CARLSBADINSPECTION RECORD 375 SF 1ST FLR COMMERCIAL/1,772 SF L1V/444 SFBuilding Division GAR/ 76 SF BALCONY/ 646 SF ROOF DECK
INSPECTION RECORD CARD WITH APPROVED RESDNTL CONDO
PLANS MUST BE KEPT ON THE JOB Lot#:26 TAYLOR MORRISON OF CA, LLC
CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION
El FOR BUILDING INSPECTION CALL:760-602-2725
OR GO TO:ingisCadikaggadayAuffding AND CLICK ON RECORD COPY"Request Inspection"
DATE:Co-
it-"YLS i -.T }.c;.1 .1-_(.0111.i-L. I.1.(1.}.1 Iris.F I rYIt it f toII
IF ()It .Pr 4 -L T i}.1 i IC:HLL 0111 T ..rn a .a„.
I t I(r.L n OFF—f ,_,`"t o
BRING IN C .(xi)IC 1 I NI..t)C (A a -E .(lirD
nT ii.C)t.Ly—.2700 UV/7 '1t1 (Fir o.LY or YOUR IN—I
NO 1:31 Required Prior to Requesting Building Final If Checked YES Date Inspector Notes
imsPlanning/Landscape 760-944-8463 Allow 48 hours 1.'12-.11 EMINE=cm&I (Engineering inspections)760-438-3891 Call before 2 pm r//2 'EMIR'NunFire Prevention 760-6024660 Allow 48 hours e AMU'
Tsui of Inspection Type of In •
BUILDING COa ELECTRIC AL Date Inspector
#11 FOUNDATION j.,/(e #31 0 ELECTRIC UNDERGROUND UFER
#12 REINFORCED STEEL /1.../#34 ROUGH ELECTRIC
#66 MASONRY ME GROUT #33 0 ELECTRIC SERVICE 0 TEMPORARY
0 GROUT 0WALL DRAINS #35 PHOTOVOLTAIC
#10 TILT PANELS #39 FINAL
#11 POUR STRIPS C C MECHANICAL
#11 COLUMN FOOTINGS #41 UNDERGROUND DUCTS &PIPING
#14 SUBFRAME 0 FLOOR 0 CEILING #44 0 DUCT&PLENUM 0 REF. PIPING
#15 ROOF SHEATHING #43 HEAT-AIR COND. SYSTEMS
#13 EXT. SHEAR PANELS #49 FINAL
#16 INSULATION
#18 EXTERIOR LATH t7 #81 UNDERGROUND (11,12,21,31)
#17 INTERIOR LATH&DRYWALL //2 At/#82 DRYINALL,EXT LATH, GAS TES(17,18,23)
#51 POOLEXCA/SIEEL/50ND/FENCE #83 ROOF SHEATING, EXT SHEAR (13,1S)
#55 PREPLASTER/FINAL #84 FRAME ROUGH COMBO (24,24,34,44)Sle P-
31 I 7
#19 FINAL #85 T-Bar(14,24,34,44)
r PLUMBING Date •for #89 FINAL OCCUPANCY (19,29,33,49)
#22 0 SEWER & B CO 0 PVCO F IRE Date ins •.•
#21 UNDERGROUND OWASTE Wilt q'
#24 TOP OUT 0 WASTE 0 WM A/S UNDERGROUND VISUAL
#27 &SHOWER PAN A/SUNDERGROUND HYDRO
#23 .GAS TEST 0 GAS PIPING
112tt.4./A/S UNDERGROUND FLUSH
#25 R HEATER A/S OVERHEAD VISUAL
#28 SOLAR WATER WS OVERHEAD HYDROSTATIC
12.144
#29 FINAL A/5FINAL 07/1 1 cAlei
„can:STORM WATER F/A ROUGH-IN
#600 PRE-CONSTRUCTION MEETING F/A FINAL
#603 FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN
605 NOTICE TO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST
#607 WRITTEN WARNING FIXED EXTINGUISHING SYSTEM FINAL
#609 NOTICE OF VIOLATION MEDICAL GAS PRESSURE TEST
#610 VERBAL WARNING MEDICAL GAS FINAL
REV 1012012 SEE SACK FOR SPECIAL NOTES
r4 tE
';1
INSTALLATION CERTIFICATE CF-6R-ENV-01
Envelope —insulation; Rodin% Fenestration (Page 1 of 3)
She Address:#Enforcement Agency:Permit Number:
LOT 2011111111111111111MPPI2EET CB152729
Ifmore than one person has responsibilityfor installation ofthe items on this certificate, each person shall prepare and sign a certificate
applicable to the portion ofconstructionfor which they are responsible:alternatively. the person with chief responsibilityforconstruction shall
prepare and sign this certificate for the entire construction.411 applicable Mandatory Measures with check hoses require to be checked0 ensure
the mandatory measures have been met
Description of insulation
1.RAISED FLOOR
Material:,Brand Name:
Thickness (inches):_Nig'Thermal Resistance (R-Value):•§150(d): Minimum R-13 insulation in raised wood-frame floor or equivalent U-factor.
2.SLAB FLOOR/PERIMETER
Material:Brand Name:_______....._.....
Thickness (inches):NIA Thermal Resistance (R-Value):
Perimeter Insulation Depth (inches):
O §150(1): Water absorption rate for the insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0 perm/inch and shall be protected from physical damage and UV light deterioration.
3.EXTERIOR WALL
a.Insulation Type (c.x. Batt, Loose Fill, Spray Foam)
2X4 BATTS a.Thermal Resistance (R-Value):R-13
b..Insulation Type (ex Batt, Loose Fill, Spray Foam)b.Thermal Resistance (R-Value):R-192X6 BATTS
Brand:MANVILI E
Spray/Loose fill)Installed Actual Thickness Spray/Loose fill)
(inches):Contractor's mm installed weight/ft'lb
Manufacturer's installed weight per square foot to achieve Thermal Resistance (R-Value)
O §150(c): Minimum R-13 insulation in wood-frame wall or equivalent U-factor.
Exterior Foam Sheathing (rigid Insulation)
Material:Brand Name:
Thickness (inches):NIA Thermal Resistance (R-Value):
4.FOUNDATION WALL
Material:Brand Name:
Thickness (inches):N/A Thermal Resistance (R-Value):
5.CE1LLNG
Batt or Blanket Type:BLOVV__Brand Name:MANVILLE
Loose Fill Type:__Thermal Resistance (R-Value):_
Spray Foam Type:Brand Name:
Installed Actual Thickness (inches):_tti Contractor's min installed weight/ft'0 432 lb
Manufacturer's installed weight per square fool to achieve Thermal Resistance (R-Value):•§150(a): Minimum R-19 insulation in wood-frame ceiling or equivalent U factor.
6.ATTIC ROOF INSULATION AND/OR ATTIC RADIANT BARRIER
Material:__ _Brand Name:
Material:N/A--Brand Name:_
Thickness (inches);_Thermal Resistance (R-Value):•§118(a):Insulation installed meets Standards for Insulating Material.
O §150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16.
2008 Residential Compliance Forms August 2009
Ok
INSTALLATION CERTIFICATE CF-6R-ENV-01
Envelope —Insulation; Roofing; Fenestration (Page 2 of 3)
She Address:I Enforcement Agency:Permit Number:
LOT 26-2575 STATE STRFET I C8152729
Description of Rodin! Products
CRRC Product to Manufacturer rProduct "—IRau'Roof Product Initial Solar Aged Solar Mensal
Number'Information
i
Brand/Model Type Area Slope Weight Reflectance Refleetarsix.Eminence
0'
N/A
1 The CRRC Product ID Number can be obtained from the tool Roof Rating Council's Rated Product Directory at
WW.coolroafs.ortproducalearch.php
2 The weight in his per square feet ofthe roofing product being installed
3 Check box ifthe Aged Reflectance is a calculated value using the equation below, footnote 4
4 Ifthe aged reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the initial reflectance value from the
directory and use the equation (0.2.0 2) to obtain a calculated aged value.
DCHECKAPPLICABEE 110%BELOW IF EXEMPT FROM THE ROOFING PRODUCT 'COOL ROW-ILEQL1REAIENT0Theroofarea covered by building integrated photovoltaic panels and building integrated solar thermal panels are exempt from the above Cool
Roof criteria.0 Roof constructions that have thermal mass over the roof membrane with a weight ofat least 25 Ibife is exempted from the above Cool Roof
criteria.
To apply Liquid Field Applied Coatings, the coaling must be applied with a minimum dry mil thickness of 20 mils across the entire roofsurface and
meet minimum performance requirements listed in 4'118193 and table 118-C Select the applicable coating
0 Aluminum-Pigmented Asphalt Roof Coating 1 0 Cement-Based Roof Coating 0 Other 0 CRRC I Label Attached to CF-6R
(Note tin° CRRC 1 label is available, this compliance method cannot he used and another method is required to meet compliance).
FENESTRATION/GLAZING
Product r a I utal Quantity Add. Exterior commie
Manufacturer/Brand Name U-Product of NM'of Like Product Area Shading Dev.Locationd Special
Item (GX014.1.IX& ROM('VS)factor'SHGC'Panes Certified'(Opridnal)ft2 or Overhang Features
3
4 N/A
5
6
7
S
Use valuesfrom a fenestration product's .N11.1tC Certified Label For fenestration products without an NEW label.use the defauh values Irma Section 116. Tabk
116-A and 116-8 ofthe 2(108 Energy Efficiency Standards
2 NM:Label CenliktIleJ shall not br removed until the building in vector has verifiedOw efficiency. Enter Yes or No
O §116(a)1' Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
0 §116(a)2 and Actual fenestration products installed are equivalent to or have a lower U factor audior a lower SHGC than that specified on
the Certificate ofCompliance (Form CF I R)
911O b(a)4'.Fenestration products (except field. fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
(7oeffic rent (SHGC), and infiltration that meets the requirements of 9 b-I'.Ila)
O §1 17'Exterior doors arid windows weather-Awed;all Joints and penetrations caulked and sealed.
2008 Residential Compliance Forms August 2009
1111111111111111111111
Mk.
INSTALLATION CERTIFICATE CF-6R-ENV-01
Enveltipe —Insulation; Roofing; Fenestration (Page 3 of 3)
Site Address:Enforcement Agency:Permit Number:
LOT 26-2575 STATE STREET CB152729
DECLARATION STATEMENT•I cenify under penalty of perjury. under the laws ofthe State of California, the information pros ided on this faint is true and correct.
•I am eligible under Uivision 1 of the Business and Professions Code to accept responsibility for construction, or an authorized representative
of the person responsible for construction (responsible person).
•I certify that the installed features, materials, components, or manufactured devices identified on this certificate (the installation) conforms
to all applicable codes and regulations, and the installation is consistent with the plans and specifications approved by the enforcement
agency.
•I reviewed a copy of the Certificate ofCompliance (CF•I R) form approved by the enforcement agency that identifies the specific
requirements for the installation.I certify that the requirements detailed on the CF-IR that apply to the installation have been met.
•I will ensure that a completed. signed copy of this Installation Certificate shall be posted, or made available with the building
permit(s) issued for the building. and made available to the enforcement agency for all applicable inspections.I understand that a
signed copy of this Installation Certificate is required to be included with the documentation the builder provides to the building
owner at occupancy.
Company Name.(Installing Subcontractor or General Contractor or ft:Ida/Owner)
ROCKWELL DRYWALL INC
Responsible Person's Name;Responsible Person's Si to
BUTCH INGRAM
CSLB License Date Signed.Position With Compa t
1.114419561541/27/2017 VP OF OPERATIONS
2008 Residential Compliance I arms
v
August 1009
T
Cmitinumus Inspection Lt.Materials Testing
sorrinvEST Ah 46. Alk Ailk Al\ Alk •AIL Ali. Ak.Alk.Alk Al\ Al..4&,
Inspection & 'resting, Inc.441 Commercial Way, La Habra, CA 90631 -6168
(562) 941 -2990 • (714) 526-8441
FAX (562) 946-0026
December 12, 2016
Building Official
City of Carlsbad
Department of Building and Safety
1635 Faraday Ave
Carlsbad, California 92008
SPECIAL INSPECTOR'S FINAL PROJECT REPORT
Project Name:Seagrove Townhomes
Address:Tract #CT13-05,PH 6 Building 3
Owner:Taylor Morrison
Lot#Address Permit Lot#Address Permit
24 2583 State Street CB152731 28 2567 State Street C8152727
25 2579 State Street CB152730 29 2563 State Street CB152726
26 2575 State Street CB152729 30 2559 State Street CB152725
27 2571 State Street CB152728
This is to certify that Southwest Inspection and Testing, Inc. was employed to perform special inspection
on the above mentioned project at the above address, which required continuous inspection per section
1701 of 2013 California Building Code.
Brett Alblinger -Reinforced Concrete, Post Tensioned Concrete, ICC #0881693
Bruce Gordon -Reinforced Concrete, Post Tensioned Concrete, ICC #1133732
Based upon special inspection and materials testing written reports of this work, it is our judgment that
the inspected work was performed to the best of our knowledge, in accordance with the approved plans,
specifications and applicable workmanship provision of the California Building Co•-
,...,ovc 4+I'
44.F.•c<N •
Sincerely,.Reviewed By:ct''./?'t,..0 -A.
\CO41219.
m,
Fs .s
xA...,, ,
.../..z..z
,...,„Cnrik..--V-
Steven L.Gocibey Ian R.Waddell,P.E.
President Principal Engineer
SLG/IRW: amc For inspection and testing only. no design responsibility
expressed or implied.