HomeMy WebLinkAbout2579 ARUNDEL AVE; ; CB162211; PermitPrint Date: 06/24/2019
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
2579 Arundel Av
BLDG-Residential
2131702500
$7,554.00
Residential Permit
Work Class: Addition
Lot#:
Reference#:
Construction Type:
Bathrooms:
Orig. Plan Check#:
Plan Check#:
Description: RESDNTL-RAD SPENCE: CONVERT 165 SF TANDEM GARAGE TO BEDROOM
FEE
Total Fees:
Owner:
SENIOR STAR PROPERTIES l LC
2579 Arundle Ave
CARLSBAD, CA 92009-3066
Total Payments To Date:
Status:
Applied:
Issued:
Permit
Finaled:
Inspector:
Final
Inspection:
Balance Due:
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020{a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Building Division
Ccityof
Carlsbad
Permit No: CB162211
Closed -Finaled
06/07/2016
07/07/2016
11/07/2016
AKrog
11/07/2016
AMOUNT
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: □PLANNING □ENGINEERING □BUILDING □FIRE □HEALTH OHAZMAT/APC0
( City of Building Permit Application Plan Check No. C!B( (,,.. · 221 I
1635 Faraday Ave., Carlsbad, CA 92008 Est. Value -F 7 t:;c;tf
Carlsbad Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit email: building@carlsbadca.gov
www.carlsbadca.gov Date &./ -, I, ,_ lswPPP
JOB ADDRESS A-rv,wleL AV~ SUITEf/SPACEI/UNITf IAPz , 1 170 -z_c;-2s-1q --
CT/PROJECT# I LOT# 3 b i r HASE# I# OF UNITS I# BEDROOMS # BATHROOMS I TENANT BUSINESS NAME
1
CONSTR. TYPE
I
OR :r
DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) ,'n-/-.-b~o&-.,,,o IVI . (' ,., '""' II ..e,, D .Ji"' ,,Q +"'I i,,o/ei.. ,.., "' ~ Gl. <, <;'
J -...) ..,/ lh.\Sr .
EXISTING USE I PROPOSED USE IGAG1i"
PATIOS (SF) I DECKS (SF) FIREPLACE c{!J IAIR CO~NING I FIRE SPRINKLERS
YESQ_ N YES No □ ves[E{No□
APPLICANT NAME f")ehn,'< ~.Odle,.(__. ••o••RlY ow••• Den n ,"s ~P#\ a--ai\ /J "l +.,, /,·e S-Primary Contact
ADDRESS A-hi nolc,, l-Ali'~ ADDRESS 257 q A n,, 11 k{. A-v-<--
,
2-r 7q
CITY Okf2..,1.-S a,A:f) STATE ZIP ttwo'f CITY ~ S.PA1) STATE C4-ZIP 92-0o'f CA--
PHONt,,i;o) S-o '>-7,;l.qlf IFAX PHONT~ ~-tFAX "760) {,qt.~ ,.,-q5
EMAIL yc;,c:&,AJ tff'l-{t:, '/i!lhPo, C-olvl EMAIL..._
DESIGN PROFESSIONAL CONTRACTOR BUS. NAME
ADDRESS ADDRESS
CITY STATE ZIP CITY STATE ZIP
PHONE IFAX PHONE IFAX
EMAIL EMAIL
I STATE LIC. # STATE LIC.# I CLASS I CITY BUS. LIC.#
(Sec,. 7031.5 Business and Professions Code: Any City or Coun_ty which requires a permit to.construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such per_mit to file a signed st~tement that he 1s licensed pursu!:mt to the provisions of the Contraytor's License t,.aw fChapter 9, comme_ndlng with Secti1m 70_00 of Division 3 of the B_usmess and Professions Code} or that he ,s exempt therefrom, and the basis for the alleged exemption. Any v1olat1on of Section 7031.5 by any applicant for a permit subJects the applicant to a
civil penalty of not more than five hundred dollars {$500)).
WORKERS' COMPENSATION
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: D l have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 0 I have and wlll maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co. ______________________ Policy No. ______________ Expiration Date _________ _
~section need not be completed if the permit is for one hundred dollars ($100) or less
~ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation laws of
California. WARNING: Failure to secure workers' compem:1atlon coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), ln
addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees .
./15 CONTRACTOR SIGNATURE □AGENT DATE
OWNER-BUILDER DECLARATION
I heje6yaffirm that I am exempt from Contractor's Ucense Law for the following reason: 0 I_, _as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec, 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
□
□
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
I am exempt under Section _____ ,Business and Professions Code for this reason
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0Yes 0No
2. I (have/ have not) signed an application for a building permit for the proposed work,
3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone I contractors' license number)·
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone/ contractors' license number):
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone I type of work):
Ji5 PROPERTY OWNER SIGNATURE □AGENT DATE 06 07 /6
.. -
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and preven~on program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? □ Yes □ No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 Yes □ No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES ANO THE AIR POLLUTION CONTROL DISTRICT.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there 1s a construction lending agency for the performance of the work this permit 1s issued (Sec 3097 (1) Civil Code)
Lender's Name Lender's Address
APPLICANT CERTIFICATION
I certify that I have read the application and state that the above infonnation Is oorrectand that the infonnation on the plans is accurate. I agree to comply with all Cltyortllnancas and Stat.e l&\S relating to building oonstructlon.
I hereby authortze representative of the City of Carlsbad to enteruJX)n the aOOve mentioned property bf in~ purp::ises. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST AlL LIAfllUTIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AG.AJNST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA: AA OSHA permit is requred for excavations over 5(1 deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Building Offcial under the provisbns of this c.ode shall expire by !imitation and beOJme null and voi::l ~ the buik:Jing oroork authorized by sucll permit is notcommeroad 'Mthin
180 days rrorn the date of such pennit or if the building orWJ/k authorized by sudl · · .s~pended or abancbnedjl any time after the WJ1k is commenced for a perKld Jj, 180days (~On 106.4.4 Uniform Building Code),
,@S° APPLICANT'S SIGNATURE DATE O (. ( O 7 / / b
• STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE.
Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection.
Fax (760) 602-8560, Email building@carlsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008.
CONTACT NAME
ADDRESS
CITY STATE ZIP
PHONE FAX
EMAIL
DELIVERY OPllONS
PICK UP: □ CONTACT (Listed above) o OCCUPANT (Listed above)
□ CONTRACTOR (On Pg. 1)
MAIL TO: □ CONTACT (Listed above) □ OCCUPANT (Listed above)
o CONTRACTOR (On Pg. 1)
MAIL/ FAX TO OTHER, _______________ _
A$ APPLICANT'S SIGNATURE
CO#: (Office Use Only)
OCCUPANT NAME
BUILDING ADDRESS
CITY STATE
Carlsbad CA
OCCUPANT'S BUS. UC. No.
□ ASSOCIATED CB#------------
□ NO CHANGE IN USE/ NO CONSTRUCTION
o CHANGE OF USE/ NO CONSTRUCTION
DATE
ZIP
PERMIT INSPECTION HISTORY REPORT (CB162211)
Permit Type: BLDG-Residential Application Date: 06/07/2016 Owner: SENIOR STAR PROPERTIES LL C
Work Class: Addition Issue Date: 07/07/2016 Subdivision:
Status: Closed -Finaled Expiration Date: 04/19/2017 Address: 2579 Arundel Av
Carlsbad, CA
IVR Number: 715018
Actual Scheduled
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Relnspection Complete
11/07/2016 11/07/2016
June 24, 2019
BLOG-Final
Inspection
000046-2016
Checklist Item
BLDG-Building Deficiency
BLDG-Structural Final
BLDG-Electrical Final
Passed Andy Krogh
COMMENTS Passed
Yes
Yes
Yes
Complete
Page 1 of 1
EsGil Corporation
In <l'artnersnip witn qovernment for <Bui(aing Safety
DATE: 6/29/2016
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 16-2211
PROJECT ADDRESS: 2579 Arundel Ave.
SET: II
PROJECT NAME: Spence Residence Remodel & Addition
~ ~:~CANT
□ PLAN REVIEWER
□ FILE
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
~ EsGil Corporation staff did not advise the applicant that the plan check has been completed.
D EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted. e , Telephone#:
Date contacted:~ ~ ) Email:
Mail Telephone Fax Person
0 REMARKS:
By: David Yao Enclosures:
EsGil Corporation
□ GA □ EJ □ MB □ PC 6/23
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
EsGil Corporation
In <Partnersnip witn qo11ernment for (JJuiUing Safety
DATE: 6/17/2016
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 16-2211
PROJECT ADDRESS: 2579 Arundel Ave.
SET: I
PROJECT NAME: Spence Residence Remodel & Addition
~PLICANT
~ :_~RIS
□ PLAN REVIEWER
□ FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
0 The check list transmitted herewith is for your information. The plans are being held at EsGil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
0 The applicant's copy of the check list has been sent to:
Dennis Spence
D EsGil Corporation staff did not advise the applicant that the plan check has been completed.
0 EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Dennis Spence
_,,.J)ate c~tacted: lt, / \ ~by:r'C-} Email:
~aiV Telephone Fax In Person
0 REMARKS:
Telephone#: 760-505-7294
yadan444@yahoo.com
By: David Yao Enclosures:
EsGil Corporation
□ GA □ EJ □ MB □ PC 6/9
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
.City of Carlsbad 16-2211
6/17/2016
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO.: 16-2211 JURISDICTION: City of Carlsbad
PROJECT ADDRESS: 2579 Arundel Ave.
FLOOR AREA:
Convert tandem garage to bedroom
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: 6/17/2016
FOREWORD (PLEASE READ):
STORIES: 1
HEIGHT:
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 6/9
PLAN REVIEWER: David Yao
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2013 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC,
2012 UPC, 2012 UMC and 2011 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2012 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
,City of Carlsbad 16-2211
6/17/2016
Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
1. All sheets of plans must be signed by the person responsible for their
preparation. (California Business and Professions Code).
2. Please indicate on the plans whether the existing residence has a fire sprinkler
system installed. If so, then provide a note stating that any additions/alterations
will be provided with an automatic residential fire sprinkler system. Section
R313.2.
3. Show locations of permanently wired smoke alarms with battery backup, per
Section R314:
a) Inside each bedroom.
b} Outside each separate sleeping area in the immediate vicinity of the
bedrooms.
c) On each story, including basements.
• NOTE: When more than one smoke alarm is required to be installed, the
alarm devices shall be interconnected in such a manner that the actuation of
one alarm will activate all of the alarms in the unit.
4. In existing buildings, when alterations, repairs or additions requiring a permit
occur (or when one or more sleeping rooms are added), the dwelling unit shall
be provided with smoke alarms located as required for new dwellings; the
smoke alarms shall be interconnected and hard wired. Exception: Smoke alarms
in existing areas need not be interconnected and hard wired where the
alterations or repairs do not result in the removal of interior wall or ceiling finishes
exposing the structure, unless there is an attic, crawl space, or basement
available which could provide access for hard wiring and interconnection without
the removal of interior finishes. Section R314.3.1.
City of Carlsbad 16-2211
6/17/2016
5. Specify on the plans that any existing smoke alarms that are more than 10
years old will be replaced. Section R314.3.2.
6. In dwelling units within which fuel-burning appliances are installed (and in
dwelling units having attached garages}. show the locations of permanently wired
carbon monoxide alarms with battery backup, per Section R315:
a) Outside each separate sleeping area in the immediate vicinity of the
bedrooms.
b) On each story, including basements.
• NOTE: When more than one carbon monoxide alarm is required to be
installed. the alarm devices shall be interconnected in such a manner that the
actuation of one alarm will activate all of the alarms in the unit.
7. When alterations, repairs or additions are proposed for dwelling units within
which fuel-burning appliances are installed (and in dwelling units having attached
garages). the dwelling unit shall be provided with carbon monoxide alarms
located as required for new dwellings; the carbon monoxide alarms shall be
interconnected and hard wired. Exception: Carbon monoxide alarms in existing
areas need not be interconnected and hard wired where the alterations or repairs
do not result in the removal of interior wall or ceiling finishes exposing the
structure, unless there is an attic. crawl space. or basement available which
could provide access for hard wiring and interconnection without the removal of
interior finishes. Section R315.2.
8. Sleeping rooms shall have a window or exterior door for emergency escape.
Section R31 O.
a) Windows must have an openable area of at least 5.7 square feet, with the
minimum openable width 20" and the minimum openable height 24".
b) The bottom of the clear opening shall not exceed 44" above the floor.
Do not measure to the window sill. This generally applies to windows that
have a height of 3' or less. See the figure below to see the correct
method of measurement.
City of Carlsbad 16-2211
6/17/2016
c) Such openings shall open directly into a public way or a court that
opens to a public way (4-sided courts are prohibited).
d) The emergency door or window shall be openable from the inside to
provide a full, clear opening without the use of any keys or tools.
9. Glazing in the following locations should be shown on the plans as safety glazing
material in accordance with Section R308.4:
a) Glazing adjacent to a door where the nearest vertical edge of the glazing is
within a 24" arc of either vertical edge of the door in a closed position and
where the bottom exposed edge of the glazing is less than 60" above the
walking surface. (2'-8"x5'-4" window next to existing door)
10. Show a self-closing, self-latching door, either 1-3/8" solid core or a listed 20 -
minute assembly, for openings between garage and dwelling. Section R302.5.1.
11. Garages are not permitted to open into a room used for sleeping purposes.
Section R302.5.1.
12. Note on the plans that receptacle outlet locations will comply with CEC Article
210.52.
13. Include on the plans the following specifications for electrical devices installed in
dwellings: CEC Article 210 & 406
City of Carlsbad 16-2211
6/17/2016
a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all
receptacles in a dwelling).
b) Arc-fault protection for all outlets (not just receptacles) located in rooms
described in NEC 210.8(A): Family, living, bedrooms, dining, halls, etc.
14. Specify on the plans whether the existing house was built before or after 1994.
For additions or improvements to a residence built before 1994, note on the
plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons
of water per flush, urinals that use more than one gallon of water per flush,
showerheads that have a flow capacity of more than 2.5 gallons of water per
minute, and interior faucets that emit more than 2.2 gallons of water per minute)
shall be replaced. Certification of compliance shall be given to the building
inspector prior to final permit approval. California SB407.
• RESIDENTIAL GREEN BUILDING STANDARDS
The California Building Standards Commission has adopted the Green Building
Standards Code which became effective January 1, 2011 and must be enforced by the
local building official. The following mandatory requirements for residential construction
must be included on your plans. CGC Section 101.3. The Standards apply to newly
constructed residential buildings, along with additions/alterations that increase the
building's conditioned area, volume or size. CGC Section 303.1.1. Provide a sheet on
the plans labeled "Green Building Code Requirements" and include the following
notes as applicable.
15. Recycling. Note on the plans that a minimum of 50% of construction waste is to
be recycled. CGC 4.408.1.
16. Recycling. Note on the plans that the contractor shall submit a Construction
Waste Management Plan to the jurisdiction agency that regulates waste
management, per CGC 4.408.2.
17. Operation and maintenance manual. Note on the plans that the builder is to
provide an operation manual (containing information for maintaining appliances,
etc.) for the owner at the time of final inspection. CGC 4.410.1.
18. Pollutant control. Note on the plans that during construction, ends of duct
openings are to be sealed, and mechanical equipment is to be covered. CGC
4.504.1.
19. Pollutant control. Note on the plans that VOC's must comply with the
limitations listed in Section 4.504.3 and Tables 4.504.1, 4.504.2, 4.504.3 and
4.504.5 for: Adhesives, Paints and Coatings, Carpet and Composition Wood
Products. CGC 4.504.2.
20. Interior moisture control. Note on the plans that the moisture content of wood
shall not exceed 19% before it is enclosed in construction. The moisture content
needs to be certified by one of 3 methods specified in Section 4.505.3. Building
City of Carlsbad 16-2211
6/17/2016
materials with visible signs of water damage should not be used in construction.
The moisture content must be determined by the contractor by one of the
methods listed in CGC 4.505.3.
21. Note on the plans that prior to final inspection the licensed contractor, architect
or engineer in responsible charge of the overall construction must provide to the
building department official written verification that all applicable provisions
from the Green Building Standards Code have been implemented as part of the
construction. CGC 102.3.
• ENERGY CONSERVATION
22. Please noted on the plan new glazing shall have min. U=.32 and SHGC=.25.
23. Residential energy lighting requirements: ES 150.0(k)
• High efficacy fixtures are required for all rooms (other than kitchen, garage,
laundry) or low efficacy fixtures are allowed if controlled by a dimmer or a
vacancy sensor.
• Outdoor lighting fixtures that are attached to a building are required to be high
efficacy or be controlled by a combination photo-control/ motion sensor.
• MISCELLANEOUS
24. To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
25. Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes □ No □
26. The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact David Yao at EsGil
Corporation. Thank you.
City of Carlsbad 16-2211
6/17/2016
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad
PREPARED BY: David Yao
BUILDING ADDRESS: 2579 Arundel Ave.
BUILDING OCCUPANCY: R3/U
BUILDING AREA Valuation
PORTION ( Sq. Ft.) Multiplier
convert tendem
to bedroom
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
--------------~
Bldg. Permit Fee by Ordinance • ------------------
Plan Check Fee by Ordinance _3
Type of Review: 0 Complete Review
D Repetitive Fee ---.;:i Repeats
D Other
D Hourly
EsGII Fee
PLAN CHECK NO.: 16-2211
DATE: 6/17/2016
Reg. VALUE ($)
Mod.
per city
D Structural Only
7,554
7,554
$96.851
$62.951
$54.241
Comments: In addition to the above fee, an additional fee of $43 is due (1 hour@
$86/hr.) for the CalGreen review.
Sheet 1 of 1
macvalue.doc +
«1q
~ CITY Of
CARLSBAD
PLANNING DIVISION
BUILDING PLAN CHECK
APPROVAL
P-29
DATE: 6-8-16 PROJECT NAME: PROJECT ID:
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.e:ov
PLAN CHECK NO: CB 16-2211 SET#: 1 ADDRESS: 2579 Arundel Av APN: 213-170-25-00
~ This plan check review is complete and has been APPROVED by the Planning
Division.
By: Chris Sexton
A Final Inspection by the Planning Division is required D Yes [8'.J No
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check APPROVAL has been sent to:
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
PLANNING ENGINEERING FIRE PREVENTION
76D-602-4610 76D-602-2750 760-602-4665
[g] Chris Sexton □ Chris Glassen □ Greg Ryan
760-602-4624 760-602-2784 760-602-4663
Chris.Sexton@tarl~badGa.gov Christogher.Glassen@carlsbadca.gov Gregory:.Ryan@!:;arlsbadca.gov
□ Gina Ruiz □ Val Ray Marshall □ Cindy Wong
760-602-4675 760-602-27 41 760-602-4662
Gina.Ruiz@cgrl~badGii:1-gQv ValRay.Marshall@carlsbadca.gov Cynthia.Wong@carlsbadca.gov
□ Veronica Morones □ Linda Ontiveros □ Dominic Fieri
760-602-4619 760-602-2773 760-602-4664
Veronica.Morones@carlsbadca.gov linda.Ontiveros@carlsbadca.gov Dominic.Fieri@carlsbadca.gov
Remarks: