Loading...
HomeMy WebLinkAbout2581 STATE ST; ; CB152714; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 02 -18-2016 Residential Permit Permit No: CB152714 Building Inspection Request Line (760) 602-2725 Job Address:2581 STATE ST CBAD Permit Type:RESDNTL Sub Type: CONDO Status: ISSUED Parcel No:2030543416 Lot #:16 Applied: 08/20/2015 Valuation:$295,759.00 Constuction Type: 5B Entered By: JMA Occupancy Group:Reference #: CT130005 Plan Approved: 02/18/2016 # Dwelling Units:1 Structure Type: MF5+Issued: 02/18/2016 Bedrooms:0 Bathrooms:0 Inspect Area: PY Orig PC #: PC140037 Plan Check #: PC150047 Project Title:STATE ST. TOWNHOMES: PHS 5 Cl 405 SF 1ST FLR COMMERCIAL/1,694 SF LIV/ 476 SF GAR/ 67 SF •BALCONY/ 585 SF ROOF DECK Applicant:Owner: TAYLOR MORRISON OF CA, LLC STE 1450 100 SPECTRUM DR IRVINE CA 92618-4935 949-341-1289 Building Permit $1,317.94 Meter Size FS1 Add'I Building Permit Fee $0.00 Add'I Red. Water Con. Fee $0.00 Plan Check $922.56 Meter Fee $317.00 Add'I Plan Check Fee ($500.00)SDCWA Fee $4,800.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $38.45 PFF (3105540)$5,382.81 Park in Lieu Fee $6,190.00 PFF (4305540)$4,968.75 Park Fee $0.00 License Tax (3104193)$0.00 LFM Fee $0.00 License Tax (4304193)$0.00 Bridge Fee $0.00 Traffic Impact Fee (3105541)$0.00 Other Bridge Fee $0.00 Traffic Impact Fee (4305541)$0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BTD #3 Fee $0.00 PLUMBING TOTAL $210.00 Renewal Fee $0.00 ELECTRICAL TOTAL $89.00 Add'I Renewal Fee $0.00 MECHANICAL TOTAL $65.38 Other Building Fee $0.00 Housing Impact Fee $0.00 HMP Fee $0.00 Housing InLieu Fee $0.00 Pot. Water Con. Fee $3,931.00 Housing Credit Fee $0.00 Meter Size FS1 Master Drainage Fee $0.00 Add'I Pot. Water Con. Fee $3.00 Sewer Fee $881.00 Reel. Water Con. Fee $0.00 Additional Fees $202.00 Green Bldg Stands (SB1473) Fee $12.00 Fire Sprinkler Fees $0.00 Green Bldg Stands Plan Chk Fee $0.00 TOTAL PERMIT FEES $28,830.89 Total Fees:$28,830.89 otal Payments to Date:$28,830.89 Balance Due:$0.00 FINALIPR/ALInspector' Date:Z5 24)(7 Clearance: NOTICE:Please t.•CE that approval dyour project includes the"I •ion"fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/-.ions."You have 90 days from the date this perrrit was issued to protest irrposition of these fees/exactions.If you protest taroit you must fdlcwthe protest • .6;.•res set forth in Government Code Section 66020(a), and file the protest and any other required information Wth the City Managerfa processing in with Carlsbad Municipal Code Section 3.32.030.Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTI-ERNOTIFIED that your right to protest the specified feeslexadions DOES NOT APPLY to water and saner connecticn fees and capacity changes, nor planning, zoning, gracing or other similar application processing or service fees in connection with this project.NCR DOES IT APPLY to any fees/exactions of which vou have deviously been riven a NOTICE similar to this. or as to which the statute of limitations has Previously otherwisemired. .••. PERMIT. INSPECTION HISTORY REPORT (CB152714)•• Permit Typo:BLDG-Residential Application Date:08/20/2015 Owner: Work Class:Condo Issue Date:02/18/2016 Subdivision: Status.Closed -Finaled Expiration Date:09/01/2017 Address:2581 State St Carlsbad, CA IVR Number:708720 Scheduled Actual Date Start Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete 11/09/2016 11/09/2016 BLDG-15 000398-2016 Passed Paul York Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 11/21/2016 11/21/2016 BLDG-13 Shear 002039-2016 Failed-Construction Paul York Reinspection Complete Panels/HD (ok to Change Needed wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 11/28/2016 11/28/2016 BLDG-13 Shear 002921-2016 Failed Paul Burnette Reinspection Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 11/30/2016 11/30/2016 BLDG-13 Shear 003497-2016 Failed-Construction Paul York Reinspection Complete Panels/HD (ok to Change Needed wrap) Checklist item COMMENTS Passed BLDG-Building Deficiency No 12/01/2016 12/01/2016 BLDG-13 Shear 003756-2016 Passed Paul York Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 12/22/2016 12/21/2016 BLDG-84 Rough 006538-2016 Passed Paul York Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 01/09/2017 01/09/2017 BLDG-82 Drywall,008801 -2017 Passed Paul York Complete Exterior Lath, Gas Test, Hot Mop "-""•. March 28, 2017 Page 1 of 2 •.. .• •••• . •PERMIT INSPECTION. HISTORY REPORT (C13.152714) P rmit Type:BLDG-Residential Application Date:08/20/2015 Owner: Work Class:Condo Issue Date:02/18/2016 Subdivision: Status:Closed -Finaled Expiration Date:09/01/2017 Address:2581 State St Carlsbad, CA IVR Number:708720 Scheduled Actual Date Start Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete Checklist item COMMENTS Passed BLDG-Building Deficiency No BLDG-17 Interior Lath-Drywall No BLDG-18 Exterior Lath and No Drywall BLDG-23 Gas-Test-Repairs No 02/23/2017 02/23/2017 BLDG-Electric Meter 014421 -2017 Failed-Construction Paul York Reinspection Complete Release Change Needed Checklist item COMMENTS Passed BLDG-Building Deficiency No 02/28/2017 02/28/2017 BLDG-Electric Meter 014843-2017 Passed Paul York Complete Release Checklist Item COMMENTS Passed BLDG-Building Deficiency No 03/20/2017 BLDG-Fire Final 017241 -2017 Scheduled Dominic Fieri Incomplete Checklist item COMMENTS Passed FIRE-Building Final No 03128/2017 03/28/2017 BLDG-Final 017925-2017 Passed Paul York Complete Inspection Checklist item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes March 28, 2017 Page 2 of 2 Inspection List Permit#:CB152714 Type:RESDNTL CONDO STATE ST. TOWNHOMES: PHS 5 C1 405 SF 1ST FLR COMMERCIAL/1,694 SF L Date Inspection Item Inspector Act Comments 11/01/2016 17 Interior Lath/Drywall PY PA 10/27/2016 15 Roof/Reroof PD PA 10/11/2016 17 Interior Lath/Drywall PD PA 09/21/2016 17 Interior Lath/Drywall PY PA 08/29/2016 11 Ftg/Foundation/Piers PY AP 08/12/2016 21 Underground/Under Floor PY AP 08/11/2016 21 Underground/Under Floor PY CO Wednesday, March 29, 2017 Page 1 of 1 Crittiimums Inveettott (4::.1faterial% Tevting tsouThwEsr Allb..A. Ai...&..41\A.411&.Ai.Alk Alk..Al.AIL AL A. Ak Inspection & 'resting,Inc.441 Commercial Way. La Habra. CA 90631 -6168 (562)941 -2990 • (714) 526-8441 FAX (562) 946-0026 December 12, 2016 Building Official City of Carlsbad Department of Building and Safety 1635 Faraday Ave Carlsbad, California 92008 SPECIAL INSPECTOR'S FINAL PROJECT REPORT Project Name:Seagrove Townhomes Address:Tract #CT13-05,PH 5 Building 2 Owner:Taylor Morrison Lot#Address Permit Lot#Address Permit 10 2557 State Street CB152706 14 2573 State Street CB152712 11 2561 State Street CB152709 15 2577 State Street CB152713 12 2565 State Street CB152710 16 2581 State Street CB152714 13 2569 State Street CB152711 17 2585 State Street CB152707 This is to certify that Southwest Inspection and Testing, Inc. was employed to perform special inspection on the above mentioned project at the above address, which required continuous inspection per section 1701 of 2013 California Building Code. Brett Alblinger -Reinforced Concrete, Post Tensioned Concrete, ICC #0881693 Bruce Gordon -Reinforced Concrete, Post Tensioned Concrete, ICC #1133732 Larry E Robertson -Reinforced Concrete, Post Tensioned Concrete, ICC #5090690 Based upon special inspection and materials testing written reports of this work, it is our judgment that the inspected work was performed to the best of our knowledge,in accordance with the approved plans, specifications and applicable workmanship provision of the California Building Code. 9ckoFE -- -7;--N\ cu j" . );\ ::0:112.7:4% Sincerel Reviewed By: f---.4",-4,/ft -._."CL M SZtrar:/e ''kyl..EXI?3.3*/./ 7 4. ,\\\.\\,,.„_,,,,,:C.:/i/ii. -..* Steven L.Goey Ian R.Waddell,P.E.QF f4'.*u.President Principal Engineer SLG/IRW: amc For inspection and testing only. no design responsibility expressed or implied. \-lifA.CB152714 2581 STATE STCITYOF CARLSBAD INSPECTION RECORD STATE ST. TOWNHOMES: PHS 5 Cl 405 SF 1ST FLR COMMERCIAL/1,694 SF LIVI 476 SFBuilding Division GAR/ 67 SF BALCONY/ 585 SF ROOF DECK INSPECTION RECORD CARD WITH APPROVED RESDNTL CONDO PLANS MUST BE KEPT ON THE JOB Lot#:16 TAYLOR MORRISON OF CA, LLC WI CALL BEFORE 3:30 Dm FOR NEXT WORK DAY INSPECTION IZ FOR BUILDING INSPECTION CALL.:760-602-2725 OR GO TO:A A Ir'''h •_I l'I'lk• AND CLICK ON '< ...t 1/4....0 R D COPY-Ro -..- DATE:0 I i .„.. IF YES 6.C HL(kr0 1 -11 1 OW THAT DIVISION '.\PPROV 11_IS REQUIRED 1 I 'U'R_I n1IF -;I .hl A 1 IN NI run DING IN .PI CTION IF YOU 1 1 1 VL ANY QUESTIONS FIEASE CALL THL Al-'1-1 IC \F Er IDIV1 -.10Ne,AT TFIF.PHONE NUM [II Fe PROV11.1 1)131 I OW.AF TER ALL REQUIRFO r-'F'FROV 1 1 .ARE SIGNED OFF -FAX TO 760 602 8560 FM \ ll TO F'f IN -F f i .i ^.V OR [3 12 INC IN rA COF'Y of TI I -. CARD TO 1 635 FARADAY Avi C 1R1 -.P ND CA 92008 BUILDING IN O-FE I 01.'.CAN FIC REAL HLD Al 760 -602 2 /00 HI FAII F N 7:30 NM -8:00 AM THE DAY OF YOUR INSPECTION. NO YES Required Prior to Requesting Building Final If Checked YES Date Inspector Notes Planning/Landscape 760-9448463 Allow 48 hours 44.1.n t-%&.e Xavt&I (Engineering inspections)760-438-3891 Call before 2 pm . zz1n q - ]mil°- 1Fire Prevention 760-6024660 Allow48 hours .e. •of In •.••Type of Ins •••n Cone It BUILDING Da ins •or c .r>t a ELECTRICAL Date Inspector #11 FOUNDATION •P9 21.44 -#31 0 ELECTRIC UNDERGROUND 0 UFER #12 REINFORCED STEEL #34 ROUGH ELECTRIC #66 MASONRY PRE GROUT #33 0 ELECTRIC SERVICE 0 TEMPORARY 0 GROUT 0 WALL DRAINS #35 PHOTO VOLTAIC #10 TILT PANELS #39 ANAL #11 POUR STRIPS CODEIt MECHANICAL #11 COLUMN FOOTINGS #41 UNDERGROUND DUCTS &PIPING #14 SUBFRAME 0 FLOOR 0 CEILING #44 0 DUCT &PLENUM 0 REF. PIPING #15 ROOF SHEATHING it'' if?#43 HEAT-AIR COND. SYSTEMS #13 EXT. SHEAR PANELS /*/AP/t „ef #49 ANAL #16 INSULATION Con.a COMBO INSPECTION #18 EXTERIOR LATH I ittre 1—ifrp.re. #81 UNDERGROUND (11,12,21,31) #17 INTERIOR LATH &DRYWALL #82 DRYWALL,Exr LATH, GAS TES (17,18,23) #51 POOLEXC/LITEEL/BOND/FENCE #63 ROOF SHEATING, EXI'SHEAR (13,16) #55 PREPLAS1ER/FINA1 #84 FRAME ROUGH COMBO (14,24,34,44) t $,42--11 1 1(.v fi.."'#19 FINAL #85 T-Bar (14,24,34,44) cot.L 1 PLUMBING pat Ins •ector #89 FINAL OCCUPANCY (19,29,39,49) #22 0 SEWER &B CO 0 CO /ffierffir4rjfilli FIRE Date Ins •.•r #21 UNDERGROUND OWASTE 0 WTR ;P /' #24 TOP OUT El WASTE 0 WTR A/S UNDERGROUND VISUAL #27 Tyr &SHOWER PAN A/S UNDERGROUND HYDRO #23L ...4•tAS TEST 0 GAS PIPING i /9/7 _ /)7.---- A/S UNDERGROUND FLUSH #25 WATER HEATER A/S OVERHEAD VISUAL ,ii.r Leit,#28 SOLAR WATER A/S OVERHEAD HYDROSTATIC I #29 FINAL A/S FINAL .v")i5W4N cr r r STORM WATER F/A. ROUGH-IN #600 PRE-CONSTRUCTION MEETING F/A FINAL #603 FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN 305 NOTICE TO CLEAN FIXED EXTINO SYSTEM HYDROSTATIC TEST #607 WRITTEN WARNING FIXED EXTINGUISHING SYSTEM FINAL #609 NOTICE OF VIOLATION MEDICAL GAS PRESSURE TEST #610 VERBAL WARNING MEDICAL GAS FINAL REV 10/2012 SEE BACK FOR SPECIAL NOTES Development ServicesCCity of CIRCUIT CARD Building Division CB -36 •.1635 Faraday Avenue . .arlsbad 760-602-2719 "7 www.carlsbadca.gov THIS CARD MUST BE FILLED OUT AND AVAILABLE AT THE SERVICE EQUIPMENT FOR THE ROUGH INSPECTION Address:Z5-13(54.. tt.-7kr.u.4--Permit Number: Owner:Phone:Area in Sq. Ft. Contractor:Phone: PANEL:A.I.C.(>a VOLTS _kW 0 1/0 WIRE BKR WIRE WIRE BKRLOCATIONCKTMISCRECRECLTGMISC CKT LOCATIONSIZESIZETYPESIZETYPESIZE (1\1•17.Cli 1 t )t."4 wid 1 1,•jo t4 A fr to)t s—2 140r ‘7-- TM.re C.3 1.4 el.A I tt4 c s—4 Voto4..(45 _GclP 5 1/0 t1 i `1 CL VA ,L 5 --6 iltiki-CA0--s 114 -1/Atpit..7 4-0 VI.I 1 6 c tok I -s—8 OeZ z A FAG-9 .7-0 51-* *tvtsk,Ley A.14 1 C --- 10 t-tol 6—. ..4.eiv 11 'r ttA I C kik t c ---- 12 .1.4.te.b.=1-"c6 2..1.1.i ..1(dk0.s kik /14 L....It"0 Ow 13 gi t`A i A/C.15 -7-1-tie 'i €I l 1.4/ 7-0 16 /4 i t yaL . A/C 17 1-5"t*)1 5-i .1.-_z_()18 54..t..('-i .Z1 c-jc..silo..19 i '5-- .k*.k 'b 20 21 22 23 24 .... 25 26 27 28 29 30 31 -32 33 34 35 36 37 38 39 \ '40 41 .42 • MAIN:0 (1.1)0 AMP BRK/FUSE El MLO Computed Load AMPS BUS:AMP See Calculation Worksheet on back Branch circuits required: Service entrance or fee_c_lei;cotrictors: A) Lighting Circuits 220 -3(b), 4(d)A) Size: No.keg"1 0 B) Type:0 CU I2i/AL B) Two Small Appliance Circuits 210 -11(e) C) Insulation:D) Conduit Size://f.C) Laundry Circuit 220 -16(b) Service ground/bond:D) Central Heating Equipment 422 -12 A) Size: No.Vi)B) Type:2PCU 0 AL E) Bathroom 210 -52(d) C) Clamp location(): UFER 250 -50(c)Remarks:0 Water Pipe 250 -1040Ground Rod 250 -52 • o (SCI locations 210 -8,680 -70:k / certify that all terminations have been torqued in accordance with manufacturer's * -E NiBathroom(s)Kitchen instructions and that the work shown on this circuit card represents the full extent of Garage(s)OHydromassage Tub the work performed under this permit. Outdoors o 0 Owner AFCI Protected Circ. 210 -12 0 ContraCtor-7-7rA•AA".(Fi II t`-40 Bedroom(s)0 Signed --r.Date IZ -11-'& .' B-36 Page 1 of 2 Rev. 03/09 SINGLE FAMILY DWELLING ELECTRICAL SERVICE LOAD CALCULATION As an alternative method, the STANDARD METHOD found in ARTICLE 220 of the National Electric Code, may be used 1.GENERAL LIGHTING LOADS Dwelling sq. ft. x 3 VA =220-3(a)VA , Small appliance loads —220-16(a) 1500 VA x circuits =VA Laundry load —220-16(b)1500 VA x circuits ='VA General Lighting Total VA 2.COOKING EQUIPMENT LOADS —Nameplate Value Range VA =VA Cooktop VA =VA Oven (s)VA =VA Cooking Equipment Total VA 3.ELECTRIC DRYER 220-18 (Nameplate, 5000 VA minimum) Dryer VA =Dryer Total VA 4.FIXED APPLIANCE LOADS 230.30 (b) (3) Dishwasher =VA Disposal =VA Compactor =VA Water Heater =VA Hydromassage Bathtub =VA Microwave Oven =VA Built-in Vacuum =VA VA Fixed Appliance Total VA 5.OPTIONAL SUBTOTAL (Add all of the above totals)VA 6.APPLYING DEMAND FACTORS —TABLE 220-30 First 10,000 VA x 100%=10,000 VA Optional Subtotal (from line 5) { Remaining VA x 40%=VA 7.HEATING OR AC LOAD —TABLE 220-30 Larger of the Heating or AC Load =VA 8.OPTIONAL LOADS TOTAL (Add totals from lines 6 and 7) =VA 9.MINIMUM SERVICE SIZE =Optional Loads Total =Ampere 240 Volt (Please put total on front of card under Computed Load) BLDG 2 INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope —Insulation; Roofing; Fenestration (Page 1 of 3) Site Address:Enforcement Agency:Permit Number: LOT 1501081 STATE STREET.CB152714 Ifmore than one person has responsibilityfor installation ofthe items on this certificate, each person shall prepare and sign a certificate applicable to the portion ofconstructionfor which they are responsible; alternatively, the person with chief responsibilityfor construction shall prepare and sign this certificatefor the entire construction.All applicable Mandatory Measures with check boxes require to be checked to ensure the mandatary measures have been met. Description of Insulation 1.RAISED FLOOR Material:Brand Name: Thickness (inches):N/A Thermal Resistance (R-Value): 121 §150(d): Minimum R-13 insulation in raised wood-frame floor or equivalent U-factor. 2.SLAB FLOOR/PERIMETER Material:Brand Name: Thickness (inches):N/A Thermal Resistance (R-Value): Perimeter Insulation Depth (inches): §150(1):Water absorption rate for the insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 perm/inch and shall be protected from physical damage and UV light deterioration. 3.EXTERIOR WALL a.Insulation Type (e.x. Batt, Loose Fill, Spray Foam) 2X4 BATTS a.Thermal Resistance (R-Value):R-13 b..Insulation Type (e.x. Batt, Loose Fill, Spray Foam) 2X6 BATTS b.Thermal Resistance (R-Value):R-19 Brand:MANVILLE Spray/Loose fill)Installed Actual Thickness Spray/Loose fill) (inches):Contractor's min installed weight/ft2 lb Manufacturer's installed weight per square foot to achieve Thermal Resistance (R-Value) §150(c);Minimum R-13 insulation in wood-frame wall or equivalent U-factor. Exterior Foam Sheathing (rigid Insulation) Material:Brand Name: Thickness (inches):N/A Thermal Resistance (R-Value): 4.FOUNDATION WALL Material:Brand Name: Thickness (inches):N/A Thermal Resistance (R-Value): 5.CEILING Batt or Blanket Type:BAITS Brand Name:MANVILLE Loose Fill Type:Thermal Resistance (R-Value):R-30 Spray Foam Type:Brand Name: Installed Actual Thickness (inches):Contractor's min installed weight/ft'lb Manufacturer's installed weight per square foot to achieve Thermal Resistance (R-Value): O §150(a): Minimum R-19 insulation in wood-frame ceiling or equivalent U-factor. 6.ATTIC ROOF INSULATION AND/OR ATTIC RADIANT BARRIER Material:Brand Name: Material:N/A Brand Name: Thickness (inches):Thermal Resistance (R-Value):•§118(a):Insulation installed meets Standards for Insulating Material. §150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. 2008 Residential Compliance Forms August 2009 Rl flf;9 INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope —Insulation; Roofing; Fenestration (Page 2 of 3) Site Address:Enforcement Agency:Permit Number: LOT 16-2581 STATE STREET CB152714 Description of Roofing Products CRRC Product ID Manufacturer Product Roof Roof Product Initial Solar Aged Solar Thermal Number'Information Brand/Model Type Area Slope Weight'Reflectance Reflectance'Eminence 0' N/A 0' 0' 1.The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Product Directory at ww.coolroofs.org/products/search.php 2.The weight in lbs per square feet ofthe roofing product being installed 3.Check box ifthe Aged Reflectance is a calculated value using the equation below, footnote 4. 4.Ifthe aged reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the initial reflectance value from the directory anduse the equation (0.2+0.7(p„„yd -02)to obtain a calculated aged value. DCHECKAPPLICABLE BOX BELOWIFEXEMPT FROM THE ROOFING PRODUCT "COOL ROOF" REQUIREMENT: O The roofarea covered by building integrated photovoltaic panels and building integrated solar thermal panels are exempt from the above Cool Roof criteria. O Roof constructions that have thermal mass over the roof membrane with a weight ofat least 25 lb/ft:is exempted from the above Cool Roof criteria. To apply Liquid Field Applied Coatings, the coating must be applied with a minimum dry mil thickness of20 mils across the entire roofsurface and meet minimum performance requirements listed in §118(1)3 and Table 118-C Select the applicable coaling 0 Aluminum-Pigmented Asphalt Roof Coating 1 0 Cement-Based Roof Coating 1 0 Other 0 CRRC-1 Label Attached to CF-6R (Note ifno CRRC-I label is available, this compliance method cannot be used and another method is required to meet compliance). FENESTRATION/GLAZING — Product Total Quantity Add. Exterior Comments/ Manufacturer/Brand Name U-Product of NFRC of Like Product Area Shading Dev.Location/ Special Item (GROUP LIKE RODUCTS)factor'SHGC'Panes Certified"(Optional)fir or Overhang Features 2 3 4 N/A 5 6 7. R. I.Use valuesfroma fenestration product's NFRC Certified Label. For fenestration products without an NFRC label,use the default valuesfrom Section 116.Table 116-A and 116-B ofthe 2008 Energy Efficiency Standards. 2.NFRC Label Certificates shall not be removed until the building inspector has verified the efficiency. Enter Yes or No. O §.1 I 6(8)1: Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. O §116(a)2 and 3: Actual fenestration products installed are equivalent to or have a lower U-factor and/or a lower SHGC than that specified on the Certificate ofCompliance (Form CF-1R). 0 §116(a)4: Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration that meets the requirementsof §10-111(a) 0 *117: Exterior doors and windows weather-stripped; all joints and penetrations caulked and sealed. 2008 Residential Compliance ForMs August 2009 BLDG 2 INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope —Insulation; Roofing; Fenestration (Page 3 of 3) Site Address:Enforcement Agency:Permit Number: LOT 16-2581 STATE STREET CB152714 DECLARATION STATEMENT •!certify under penalty ofperjury, under the laws of the State of California, the information provided on this form is true and correct. •I am eligible under Division 3 ofthe Business and Professions Code to accept responsibility for construction, or an authorized representative of the person responsible for construction (responsible person). •1 certify that the installed features, materials, components, or manufactured devices identified on this certificate (the installation) conforms to all applicable codes and regulations, and the installation is consistent with the plans and specifications approved by the enforcement agency. •I reviewed a copy of the Certificate ofCompliance (CF-1R) form approved by the enforcement agency that identifies the specific requirements for the installation.I certify that the requirements detailed on the CF-1R that apply to the installation have been met. •I will ensure that a completed, signed copy ofthis Installation Certificate shall be posted,or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections.I understand that a signed copy of this Installation Certificate is required to be included with the documentation the builder provides to the building owner at occupancy. Company Name:(Installing Subcontractor or General Contractor or Builder/Owner) ROCKWELL DRYWALL, INC. Responsible Person's Name:Responsible Person's to BUTCH INGRAM )4'1CSLB License:Date Signed:Position With Company (Title): 956154 1/10/2017 VP OF OPERATIONS 2008 Residential Compliance Forms August 2009