HomeMy WebLinkAbout2582 LUCIERNAGA ST; ; CB110191; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
08-05-2011 Residential Permit Permit No:CB110191
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
"Valuation:
Occupancy Group:
# Dwelling Units:
• Bedrooms:
Project Title:
2582 LUCIERNAGA ST CBAD
RESDNTL Sub Type:
2152703402 Lot#:
$17,784.00 Construction Type:
Reference #:
0 Structure Type:
O Bathrooms:
ATAIE RES-ADD 98 SF TO ENTRY
RAD
0
5B
0
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
Orig PC#:
Plan Check#
Applicant: Owner:
BONNIE ATAIE
2582 LUCIERNAGA ST 92009
760 917-5515
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
HMP Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
Green Bldg Stands {SB1473) Fee
$190.61
$0.00
$123.90
$0.00
$0.00
$1.78
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$1.00
BONNIE ATAIE
2582 LUCIERNAGA ST 92009
760 917-5515
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWAFee
CFD Payoff Fee
PFF (3105540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnlieu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Additional Fees
Fire Sprinkler Fees
TOTAL PERMIT FEES
ISSUED
01/26/2011
RMA
02/09/2011
02/09/2011
PD
Total Fees: $422.79 Total Payments To Date: $422.79 Balance Due:
Inspector: Clearance:
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$55.00
$20.00
$30.50
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$422.79
$0.00
approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions.~ Y u have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or se1Vice fees in connection with this project. NOR DOES IT APPLY to any . .
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
02-09-2011
Storm Water Pollution Prevention Plan (SWPPP) Permit
Permit No:SW110022
Job Address:
Permit Type:
'Parcel No:
Reference #:
CB#:
Project Title:
Applicant:
BONNIE ATAIE
760 917-5515
Emergency Contact:
PETER ATAIE
808 781-4326
2580 LUCIERNAGA ST CBAD
SWPPP
2152703401
CB110191
ATAIE RES-ADDITION
SWPPP Plan Check
SWPPP Inspections
Additional Fees
TOTAL PERMIT FEES
Status:
Lot#: 0 Applied:
Entered By:
Issued:
Inspect Area:
Tier:
Priority:
Owner:
BUENO MARCO&CARLA
2580 LUCIERNAGA ST
CARLSBAD CA 92009
ISSUED
01/26/2011
RMA
02/09/2011
1
M
$49.00
$208.00
$0.00
$257.00
Total Fees: $257.00 Total Payments To Date: $257 .OD Balance Due:
FINAL APPROVAL
DA TE _g1~11-tJ~_ClEARANCE --f ---,._
$0.00
'
... «~~',
~ CITY OF
CARLSBAD
CONTACT NAME (If Different Fom Applicant)
ADDRESS
CITY
PHONE
EMAIL
PROPERTY OWNER NAME
CITY
PHONE
EMAIL
Bu~~ JJr.fl.t~tfc'at1on
1635 Faraday Ave., carlsbad, CA 92008
760-602-2717 / 2718 / 2719
Fax: 760-602-8558
www.carlsbadca.gov
# BATHROOMS -z_
STATE ZIP
FAX
ADDRESS
CITY
PHONE
EMAIL
STATE LIC. # STATE UC.#
STATE ZIP
FAX
CLASS CITY BUS. LIC.#
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demollsh or repair an~ structure, prior to its issuance, also requires the applicant for such permit to file a si~ed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is eKemP.t therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any appllcanffor a permit subjects the applicant to a
clvll penalty of not more than flve hundred dollars ($500}).
WORKERS' COMPENSATION
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
□ I have and will maintain a certificate of consent to utf-insure for workers' compensation as provided by Section 3700 of the labor Code, for the performance of the work for which this pennit is Issued.
D I have and will maintain workers' compensation, as required by Section 3700 of the labor Code, for the perfonnance of Iha work for which this pennil is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co. _____________________ Policy No. ______________ Expiration Date _________ _
This section need not be completed if the pennit is for ooe hundred dollars ($100) or less.
□ Certificate of Exemption: I certify that in the performance of the wort< for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' CompensaHon laws of
California. WARNING: Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil f1n91 up to one hundred thousand dollars (&100,000), In
addition to the cost of compensation, damages as provided for In Section 370fi of the Labor code, Interest and attorney's fees.
~ CONTRACTOR SIGNATURE □AGENT DATE
OWNER•BUl1.DER DECLARATION
I hereby affirm that I am exempt from Contractor's Ucsnse Law for the following reason:
1( I, as owner of the property or my employees wilh wages as their sole compensation, will do the work and the structure is not Intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License law does not apply to an owner of property 'Mio builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement Is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
□ I, as owner of the property, am exdusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License law does not apply to an owoer of
property who builds or improves thereon, and conlracts for such projects with contractor(s) licensed pursuant to the Contractor's license Law).
□ I am exempt under Section Business and Professions Code for this reason:
1 I ally plan to provide the major labor and materials for construction of the proposed property improvement. "11 Yes □ No
have not) sigl'l8d an application for a building permit for the proposed work.
contracted with the following person (firm) to provide the proposed construction (include name address/ phone I contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number):
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone I type of work):
AS PROPERTY OWNER SIGNATURE □AGENT DATle
" COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a business l acutely hazartlous materials reg1stral10r1 form or nsk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act.? □ Yes No
Is the applicant or future building occupant required to obtain a pennil from e air polluUon control disbict or air quality management district? 0 Yes ~
Is lhe facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 Yes ,,fJ No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE Of OCCUPANCY MAY NOT BE ISSUED Ltr4CESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS Of THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT,
CONSTRUCTION LENDING AGENCY
I hereby affirm that there 1s a construction lending agency for the performance of the work this permit 1s ISSUed (Sec 3097 (t) Civil Code)
Lender's Name Lender's Address
APPLICANT CERTIFICATION
I certify that I have ieadthe appllcation and state that the above infonnatlon is COl19Cland that the klformation on the plans Is accurate. I agree to comply with all City ordinances and St.ate laws relating to bulldlng construction.
I he!8by aulhorize representalNe ol "8 City of Gallsbad ~ enter upon '1e above menliloed property for i,spediJn l)Jrposes. I Al.SO AGREE TO SAVE, l~EMNIFY AND KEEP HARMLESS THE CITY Of CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN AfNWAY ACCRUE AGAJNST SA[) CITY IN CONSEQUENCE Of THE GRANTING Of THIS PERMIT.
OSHA: An OSHA pennl is requi'ed br excavations C'Nf!l 5'0' deep and demolition oc ronstruction of structures C'Nf!l 3 sb'ies ii heqlt.
EXPIRATION: Evesy pemwt issued by the Building Offcial under lhe provisi:>ns of lhis Code shall expire 17( Imitation and become null and vOKI if lhe buildhg or work aullorized by sudl pemit is not cornmeoc:ed 'Mlm
180days from '1e date of such pemit ocWtle b~::f r by penni is susper<led or abandoned at any line allartle""' is cxxnmenced for a peood ol 180 days (Secoon 106.4.4 lk1ilorm &Jiklilg Code).
A!$' APPLICANT'S SIGNATURE ~ j>( 4 ...... -.,_ DATE / • 2~ • I.
m • ' . City of Carlsbad Bldg Inspection Request
For: 08/12/2011 . .
Permit# CB110191
Title: ATAIE RES-ADD 98 SF TO ENTRY
Description:
Type: RESDNTL Sub Type: RAD
Job Address: 2582 LUCIERNAGA ST
Suite:
Location:
OWNER BONNIE ATAIE
Owner: ATAIE BONNIE
Remarks:
Total Time:
Lot: 0
CD Description Act Comments
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
---------------------
Comments/Notices/Holds
Associated PCRs/CVs/SWPPPs Original PC#
SW110022 ISSUED ATAIE RES-ADDITION:
Inspection History
Date Description Act lnsp Comments
08/05/2011 89 Final Combo co PD
05/05/2011 17 Interior Lath/Drywall AP PD
Inspector Assignment: PD ---
Phone: 7609175515 ·~~4
Requested By: NA
Entered By: CHRISTINE
04/22/2011 14 Frame/Steel/Bolting/Welding AP
04/22/2011 17 Interior Lath/Drywall co
MC
MC
INTERIOR SHEAR WALL AND HDUZ AT ENTRY OK
COMPLETE ALL DRYWALL
04/15/2011 14 Frame/Steel/Bolting/Welding co PD
04/07/2011 14 Frame/Steel/Bolting/Welding NR PY
02/24/2011 13 Shear Panels/HD's AP PD
02/24/2011 15 Roof/Reroof WC PD
02/24/2011 17 Interior Lath/Drywall WC PD
02/24/2011 18 Exterior Lath/Drywall WC PD
02/23/2011 14 Frame/Steel/Bolting/Welding WC PD
02/23/2011 15 Roof/Reroof AP PD
02/14/2011 11 Fig/Foundation/Piers AP MC PER PLAN
1 •
«~~ ~ CITY OF
CARLSBAD
BUILDING
Z!!E..-Plan Check
Comments
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
· By: Steve Borossay (Contact Hours for Steve: Tues.-Fri., 1pm-5pm) Phone: 760-602-7541
Permit: cez llO 10 I Address: Z.580 Luciec~= St. Date· -i,./4-/, I I I
· • When corrections from all departments are receiv d please run new prints •
• Please respond by indicating location of Plan Check items on plans • D Provide: A statement on the Title Sheet of the plans stating that the project shall comply with the 2010 CA Building Code, 2010
CA Residential Code, 2010 CA Green Code, 2010 CMC, 2010 CPC, 2010 CEC, 2008 CA Energy Efficiency
Standards, 2010 CA Fire Code and the Carlsbad Municipal Code
D Provide: A note titled "Scope of Work" describing the work to be performed under this permit.
~e_fer -tv CF -l '< +,-k 'V\.e-.w ~o&--, An. S,u. Q..a.~OIA_ --e ?0
I
a.."---cl ~Q.Q__ ~ ,re_ 2.1--~o '1'a.-~r5, ~ Ct.CL.o w.oda...k-.
2. Sh..-o~ wc...w Jv:, ... <L ~ 11/\,!Ll..v !;:,~ ( N)~ Ln <2,\a_b ~)
Approved on:-----~=--i-(_,_111--fl~I-----By: ___ <_,~;..,"--------------
~ -«~~ ~ CITY OF
BUILDING PLANCHECK
CHECKLIST
Development Services
Land Development Engineering
1635 Faraday Avenue
760-602-2750
www.carlsbadca.gov CARLSBAD E-36
-DATE z~ortl,, PLANcHEcK No.: ~Pc 11-1 ~ f
BUILDINGA DRE~S: ::zm Luc:-1~t-JAG s,.
PROJECT DESCRIPTION: ( L3¥-gtt½)
SW I \-z_~
ASSESSOR'S PARCEL NUMBER: Z\ 5 ---~ 2-EST. VALUE: 17, 78'tf:
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has
been approved. The approval is based on
plans, information and/or specifications
provided in your submittal; therefore any
changes to these items after this date,
including field modifications, must be reviewed
by this office to ensure continued conformance
with applicable codes. Please review carefully
all comments attached, as failure to comply
with instructions in this report can result in
suspension of permit to build.
0 A Right-of-Way permit is required prior to
construction of the following improvements:
By:
ATTACHMENTS
D Engineering Application
D Dedication Checklist
O Neighborhood Improvement Agreement
0 Grading Submittal Checklist
D Reference Documents
D Ri f-Way Permit Application and Info Sheet
DENIAL
se see the attached list of outstanding issues marked with
Make necessary corrections to plans or specifications for
pliance with applicable codes and standards. Submit
corrected plans and/or specifications to the Building Dept. for
resubmittal to the Engineering Dept. Only the applicable
sheets have been sent.
Date: _z(i-=-+-rzd_'--+-'-/ .,_
By:-----------Date: ______ _
By ____________ Date: ______ _
By ____________ Date: ______ _
Name:
email:
ENGINEERING DEPT. CONTACT PERSON
Linda Ontiveros
City of Carlsbad
linda.ontiveros@carlsbadca.gov
Phone: 760-602-2773 Fax: 760-602-1052
□
torm Water Applicability Che~~EJ Wate,S, / '\
Compliance Exemption Form \.. v-~ · ~.,. 7'1)
~ If there are retaining walls associated with your
project, please check with the building department if
these walls need to be pulled by separate RETAINING
WALL PERMIT.
E-36 Page 1 of7 REV6l30/10
SITE PLAN
1. Provide a fully dimensioned site plan drawn to scale. Show:
~orth arrow
~Existing & proposed structures
[iJ.----1:xisting street improvements
~roperty lines (show all dimensions)
Q.,/ _Easements ~ Right-of-way width & adjacent streets
~riveway widths B-Existing or proposed sewer lateral
E:I-Existing or proposed water service
B--Existing or proposed irrigation service
El-Submit on signed /approved plans:
DWG No.
D 2. Show on site plan:
t'.J Drainage patterns/ f>-Z--D)
1. Building pad surface drainage must maintain a minimum slope of one percent towards
an adjoining street or an approved drainage course.
2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage
of 2% to swale 5' away from building".
1::)-Existing & proposed slopes and topography
&Size, type, location, alignment of existing or proposed sewer and water service(s) that
serves the project. Each unit requires a separate service; however, second dwelling
units and apartment complexes are an exception. B-Sewer and water laterals should not be located within proposed driveways, per
standards.
□ 3. Include on title sheet: l ~~ l--' A ..Dl5CREPI\NC'-/ A~Wf'
Qite address J Tt\6 fl<..OfMY "· --me r"~8S'::,
@'Assessor's parcel number LJ-'..,.-e'J) fCN Tlt&. ~N! _ -rt\"{~
□ Legal description/lot number Ml\r tl::€ ~8-C.rt.D fy~---11\Ec--Cov\NlEt<._
For commercial/industrial buildings and tenant improvement projects, include: total building square
footage with the square footage for each different use, existing sewer permits showing square footage of
different uses (manufacturing, warehouse, office, etc.) previously approved.
Show all existing use of SF and new proposed use of SF.
Example:
Tenant improvement for 3500 SF of warehouse to 3500 SF of office.
EXISTING PERMIT NUMBER DESCRIPTION
'i>fi«_ t'7
Lot/Map No.: ~Ira 1'!,-lf-k"Js°} Subdivision/Tract: PM b 7"6 -g Reference no(s): ______ _
E-36 Page 2 of 7 REV 6/30110
□
□
E-36
DISCRETIONARY APPROVAL COMPLIANCE
D Project does not comply with the following engineering conditions of approval for project no._
D All conditions are in compliance. Date: __________ _
DEDICATION REQUIREMENTS
D Dedication for all street rights-of-way adjacent to the building site and any storm drain or
utility easements on the building site is required for all new buildings and for remodels with a
value at or exceeding $ 17 000.00 , pursuant to Carlsbad Municipal Code Section 18.40.030.
For single family residence, easement dedication will be completed by the City of Carlsbad,
cost $605.00.
Dedication required as follows: ________________________ _
Dedication required. Please have a registered civil engineer or land surveyor prepare the
appropriate legal description together with an 8 ½" x 11" plat map and submit with a title report. All
easement documents must be approved and signed by owner(s) prior to issuance of building
permit. Attached please find an application form and submittal checklist for the dedication
process. Submit the completed application form with the required checklist items and fees to the
engineering department in person. Applications will not be accepted by mail or fax.
Dedication completed by: _______ _ Date: _____ _
IMPROVEMENT REQUIREMENTS
D All needed public improvements upon and adjacent to the building site must be constructed
at time of building construction whenever the value of the construction ex eeds $ 82.000.00,
pursuant to Carlsbad Municipal Code Sectio 18.40.040.
D Construction of the public improvements may be deferred pursuant to Carlsbad
Municipal Code Section 18.40. Please submit a recent property title report or current grant
deed on the property and processing fee of$ 441.00 so we may prepare the necessary
Neighborhood Improvement Agreement. This agreement must be signed, notarized and
approved by the city prior to issuance of a building permit.
Page 3 of 7 REV6/30/10
□
□
~□ □
E-36
Future public improvements required as follows:
Eoclosed please find your Neighborhood Improvement Agreement. Please return agreement
signed and notarized to the engineering department.
~zborhood Improvement Agreement completed by:
dNo public improvements required. SPECIAL NOTE: Damaged or defective improvements
found adjacent to building site must be repaired to the satisfaction of the city inspector prior to
occupancy.
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section 15.16 of the
Municipal Code.
@Inadequate information available on site plan to make a determination on grading
requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and
12_medial). This information must be included on the plans. ,e_() A l\ ,,
Ut NO~[\("~'~ P~oPos Wlt(T£'(NO ~(t,./6--ON£(1E-f?LAN D Grading ::;;..Yeqi'.hfed. '"NOTE: The rad'iri, ermit must be issued and rou h radin
approval obtained prior to issuance of a building permit.
D Graded Pad Certification required. (Note: Pad certification may be required even if a grading
permit is not required.) All required documentation must be provided to your Engineering
Construction Inspector. The inspector will then provide the engineering counter with a
release for the building permit.
D No grading permit required.
MISCELLANEOUS PERMITS
D A RIGHT-OF-WAY PERMIT is required to do work in city right-of-way and/or private work
adjacent to the public right-of-way. Types of work include, but are not limited to: street
improvements, tree trimming, driveway construction, tying into public storm drain, sewer and
water utilities.
0 INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer
service area, you must complete the attached Industrial Wastewater Discharge Permit
Screening Survey. Fax or mail to Encina Wastewater Authority, 6200 Avenida Encinas,
Carlsbad, CA 92011, (760) 438-3941, Fax (760) 476-9852.
Page 4 of 7 REV6/30/10
□
E-36
reject Threat Assessment Form complete.-CoieJ<.EC1"' A1)__De-E.S S
ON ~ &=-'2-lt(ove-t<--THE -
Project Threat Assessment Form incorrectly completed. • a;vl ~ )
D Requires Tier 1 Storm Water Pollution Prevention Plan. Please complete attached form and
return (SW ___ ...1
D Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2
SWPPP, payment of processing fee and review by city.
Storm Water Standards Que~ionnaire complete.-Co~f:::Cr ,Ac-D.01'2-c5.S
c;\,I G: OV61Z--nt&-COUNTa<-. Stor~Stan~ estionnaire incorrectly completed .. \ Please make the
corrections, re-sign the questionnaire and resubmit with next submitful.
reject is subject to Standard Storm Water Requirements. See city Standard Urban
Storm Water Management Plan (SUSMP) for reference.
Disconnect discharges per SUSMP. Do not connect runoff from impervious surfaces to
storm drains without first discharging water over landscape areas. See SUSMP.
JlEs AUDtTic»-1 HAvG (1.(XF t)l2.A-1NSf" IF So, ~ J)l?,#\.1~5
~UL{) ftCl~T !Z,w-J ,tffi._DUG~ LMJD6t,Apt;:c µ.£.f.-S
fictOIC n> ~"'-s-f-f¼eLll. sro~ t)f../41'1 S'f'£T8vl.
&-Trash storage areas must be designed per city standards (GS-16) to avoid contact with
storm runoff.
g__ Project is subject to Priority Development Project Requirements.
B--Prepare and submit a Storm Water Management Plan (SWMP). Requires payment of
processing fee and review by city.
J:1_ Project does not comply with recommendations of the approved SWMP. Redesign to
comply and resubmit.
B--Required fees have been entered in building permit
g.-Drainage fee applicable
Added square feet ___ _
Added square footage in last two years? _ yes _ no
Permit No. ______________ _
Permit No. ______________ _
Project built after 1980 _yes_ no
Impervious surface> 50% _yes_ no
Impact unconstructed facility _yes_ no id--Fire sprinklers required_ yes_ no (is addition over 150' from center line)
/ Upgrade_ yes_ no
[)/ No fees required
Page 5 of7 REV 4/30/10
□
E-36
WATER METER REVIEW
--El Domestic (potable) Use
Ensure that the meter proposed by the owner/developer is not oversized. Oversized
meters are inaccurate during low-flow conditions. If it is oversized, for the life of the
meter, the city will not accurately bill the owner for the water used.
• Where a residential unit is required to have an automatic fire
extinguishing system, the minimum meter size shall be a 1"meter. NOTE:
The connection fee, SDCWA system capacity charge and the water
treatment capacity charge will be based on the size of the meter
necessary to meet the water use requirements.
• For residential units the minimum size meter shall be 5/8", except where
the residential unit is larger than 3,500 square feet or on a lot larger than
one quarter (1/4) acre where the meter size shall be¾:
• If owner/developer proposes a size other than the "standard", then
owner/developer must provide potable water demand calculations, which
include total fixture counts and maximum water demand in gallons per
minute (gpm). A typical fixture count and water demand worksheet is
attached. Once the gpm is provided, check against the "meter sizing
schedule" to verify the anticipated meter size for the unit.
• Maximum service and meter size is a 2" service with a 2" meter.
4J Irrigation Use (where recycled water is not available)
All irrigation meters must be sized by the landscape architect based on the
flow demand in gallons per minute (gpm) for the area to be irrigated. The
minimum size meter(s) shall be capable of supplying the peak irrigation water
demand determined.
• If the project is a newer development (newer than 1998), check the recent
improvement plans and observe if the new irrigation service is reflected on
the improvement sheets. If so, at the water meter station, the demand in
gpm may be listed there. Irrigation services are listed with a circled "I", and
potable water is typically a circled "W'.
• If the improvement plans do not list the irrigation meter and the
service/meter will be installed via another instrument such as the building
plans or grading plans (w/ a right of way permit of course), then the
applicant must provide irrigation calculations for estimated worst-case
irrigation demand (largest zone with the farthest reach). Typically the
planning department landscape consultant has already reviewed this if
landscape plan&.,..have been prepared, but the applicant must provide the
calculations to you for your use. Once you have received a good example of
irrigation calculations, keep a set for your reference. In general the
calculations will include:
• Hydraulic grade line
• Elevation at point of connection (POC)
• Pressure at POC in pounds per square inch (PSI)
• Worse case zone (largest, farthest away from valve)
• Total sprinkler heads listed (with gpm use per head)
• Include a 10% residual pressure at point of connection
Page 6 of 7 REV 6/'30110
□ □ □
E-36
O Irrigation Use (where recycled water is available)
1. Recycled water meters are sized the same as the irrigation meter above.
2. If a project fronts a street with recycled water, then they should be connecting to this
line to irrigate slopes within the development. For subdivisions, this should have been
identified and implemented on the improvement plans. Installing recycled water
meters is a benefit for the applicant since they are exempt from paying the San
Diego County Water Capacity fees. However, if they front a street on which the
recycled water is there, but is not live (they are charged with potable water until
recycled water is available), then the applicant must pay the San Diego Water
Capacity Charge. If recycled water is eventually supplied to the service connection
and meter within one year of the original application for Water meter Permit, the
customer must prepare and submit the San Diego County Water Authority's
"Capacity Charge Refund Request" form to CMWD for verification to request the
connection fee refund.
D Additional Comments:
Page 7 of 7 REV6/30/10
-----~~ .. fl "' ,. • CJ CJ CJ
<I) C/l
CJ CJ
~ ~ 1, D ~ ,;;; !il \'I
i i ~ ~ " " " £ C C It It
1:2100
1:21 □ □
C8J □ □
1:21 □ □
C8J □ □
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No. CB11-0191 Address 2580 Luciernaga Street
Planner Chris Sexton Phone >-'(7"'6"'0,_) =60=2e.-...,4=62.,.4"--------
APN: 215-270-34-01
Type of Project & Use: addition Net Project Density: DU/AC
Zoning: R-2 General Plan: RM Facilities Management Zone: §
CFO (in/out) #_Date of participation: __ Remaining net dev acres: __
Circle One (For non-residential development: Type of land used created by this permit:
__J
Legend: 1:8:1 Item Complet~em Incomplete • Needs your action
Environmental Review Required: YES D NO D TYPE
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Action Required: YES D NOD TYPE --
APPROVAL/RESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval: __
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES O NO 0
CA Coastal Commission Authority? YES O NO 0
If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive, Suite 103,
San Diego, CA 92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt):
Habitat Management Plan
Data Entry Completed? YES D NO D
If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and
assess fees in Permits Plus
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type
impacted/taken, UPDATE!)
lncluslonary Housing Fee required: YES D NOD
(Effective date of lnclusionary Housing Ordinance -May 21, 1993.)
Data Entry Completed? YES D NO D
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N,
Enter Fee, UPDATE!)
H:\ADMIN\Template\Building Plancheck Review Checklist.doc Rev 4/08
------·-·---·
Site Plan:
0 0 0
1310 □
ODO
000
000
13100
000
Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements,
existing and proposed structures, streets, existing street improvements, right-of-way width,
dimensional setbacks and existing topographical lines (including all side and rear yard slopes).
Provide legal description of property and assessor's parcel number.
Policy 44 -Neighborhood Architectural Design Guidelines
1 . Applicability: YES O NO D
2. Project complies: YES O NOD
Zoning:
1. Setbacks:
Front:
Interior Side:
Street Side:
Rear:
Top of slope:
Required 20' Shown 20'
Required 7.4' Shown __
Required __ Shown __
Required 14.8' Shown HJ!'.
Required __ Shown __
2. Accessory structure setbacks:
Front: Required __ Shown __
Interior Side: Required __ Shown __
Street Side: Required __ Shown __
Rear: Required __ Shown __
Structure separation: Required __ Shown __
3. Lot Coverage: Required <50% Shown 35.5%
4. Height: Required <30' Shown <30'
5. Parking: Spaces Required i Shown i
(breakdown by uses for commercial and industrial projects required)
I'!:::,. Residential Guest Spaces Required __ Shown __
U:,1)0 D Additional Comments 1 l Please provide the lot coverage on the lot.
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTE~~ATE {k:.]__ -/ /
H:\ADMIN\Template\Building Plancheck Review Checklist.doc Rev 4/08
· . NARAGHI ENGINEERING
STRUCTURAL CONSULTANT
"l..... !? 0 t,...UC., ~ft(; p.. -'
H-~ 1J ~ -~J ~/4 ~ .Ai~ ~;,/.enJ/<)"¥1,.,
&~ ~-:-
~
';5'),)j ~ ,.-,82,.
c: _J_ (/,,,,,, t.A-, r=>:? ,✓->
-"}~2 :. .• 17...-
.;&,r
~~·>"
l•f · e._ ..L r,. 9 r-12) ,d :: -111 Id
/. 'f
~/~ ~ ~ /,,/ ~2
?;~7!~-l)~ a--/ 3
-'-~ ,. (/Yr¥· //I).,
?/µ,1 . " .... .,. -JJd HJ'//· e-7 -t3
~---/1;>~~
l,l.~I
-------------·------~----------•
NARAGHI ENGINEERING JOB ________ _
SHEETNO: ____ OF __ _
STRUCTURAL CONSULTANT CALCULATED BY: DATE __ _
4'w-,,/ ""I I ,.
V• l~ ~·
V..,[~(?'f')r 7(fi)1z-.is. 117-1
~Z-1§"2 fl{ /£/
,.-f-i /. .z. . HDt/~
p~ .~ /17'( ~ --~~~/°l_....,,p ~
'7'1, {I JI-✓ Ut( ~ /itrl,1f /f ~ iv/ r o
·-' -·--· ·-----·-···-.
/)f#.,t,~f .
Conterminous 48 States
2003 NEHRP Seismic Design Provisions
Latitude= 33.10721
Longitude = -117 .24973
Spectral Response Accelerations Ss and S1
Ss and S1 = Mapped Spectral Acceleration Values
Site Class B-Fa= 1.0 ,Fv = 1.0
Data are based on a 0.009999999776482582 deg grid spacing
Period Sa
(sec) (g)
0.2 1.111 (Ss, Site Class B)
1.0 0.420 (S1, Site Class B)
Conterminous 48 States
2003 NEHRP Seismic Design Provisions
Latitude= 33.10721
Longitude= -117.24973
Spectral Response Accelerations SMs and SM1
SMs = Fax Ss and SM1 = Fv x S1
Site Class D -Fa = 1.055 ,Fv = 1.58
Period Sa
(sec) (g)
0.2 1.172 (SMs, Site Class D)
1.0 0.663 (SM1, Site Class D)
· Conterminous 48 States
2003 NEHRP Seismic Design Provisions
Latitude= 33.10721
Longitude = -117 .24973
Design Spectral Response Accelerations SDs and SD1
sos= 2/3 x SMs and SD1 = 2/3 x SM1
Site Class D -Fa = 1.055 ,Fv = 1.58
Period Sa
(sec) (g)
0.2 0.782 (SDs, Site Class D)
1.0 0.442 (SD1, Site Class D)
---------~-------._., ___ _
r
CB110191 2582 LUCIERNAGAST
AT AIE RES-ADD 98 ~ ------·.
1/;1/i1 &f/7 ~ hr,;t.,iA
~ _/_ fl-?vL-//
/-%-/! -tt,,J=/J fc. T" o
l-)7,JI hfJ~·
J-'/-11-fl/Jfii1-ff-~<Jh\f_ wjc;tud ('a/cs-i1/;_fft,, ;J;(~ff
2-t(-/( t,ft/~ff(f}-/-~. (Ju4~ /}J'r,' &:JI~
2-7-1/ ~:~_(a;*.
9Jrf /tr fJA L rf ~. 'f-c · ~#ell_
c)..,I q /' I t <;, .!,---€.-0
5-<;//-)~1 lVd~ ~ ~J)j).j;_l}-,1).
Approved
BUILDING
PLANNING
ENGINEERING
ARE-7 Y N
HazMat
APCD
Health
FormsfFees
Encina
Sent
Date
:iJ ri/77
:?_'-J_;/J
Rec'd
Fire
HazHealthAPCD
PE&M •• .J_ ;p I 1/u.1 ..
School
sewe,
Stormwater
Specialln,pection I /-{tip-// 11-1/--lf
CFD: Y N
landUse: Density: lmpArea: FY:
PFF: Y N
Comments Date Date
Building
Planning
1tm@ r-9'✓/~ 1-)7-JJ:).
Engineering IIFt/11~
Fire
Need?
SW f I ()()_ A2....
Annex:
Date
□CV
Bv
.J_
lu
I.P
Due? By
y N --y N --y N I v N I JI.•
Y N t I
y N
y N -y N I ltf~
'/
Factor:
Date
ne
□Done
□ Issued