Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2587 Wellspring St; ; CBRA2016-0021; Permit
City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Print Date: 07/24/2017 Permit Permit No: CBRA2016-0021 www.carlsbadca.gov Job Address: 2587 Wellspring St Permit Type: BLDG-Associated Permit Residentia Work Class: Parcel No: 2081903400 Lot#: Single Family Detached 184 Status: Applied: Closed -Finaled 12/12/2016 01/13/2017 Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: $488,719.08 Reference#: Construction Type: 1 Bathrooms: 4.00 Orig. Plan Check#: Plan Check#: THE VISTAS DEV2016-0039 VB 4.50 PC150042 PC2016-0007 Issued: Fina led: Inspector: JWest Description: THE VISTAS: PHASE 7 // PLAN 2 // 3,051 SF// 471 SF GARAGE// 204 SF CA ROOM// 62 SF PORCH Applicant: TOLL BROS INC JOANN EPSTINE Owner: RANCHO COSTERA LLC -2483 725 W Town And Country Rd, 200 ORANGE, CA 92868-4709 760-720-5485 725 W Town And Country Rd, 200 ORANGE, CA 92868-4723 760-729-2929 BUILDING PERMIT FEE $2000+ BUILDING PLAN CHECK FEE (BLDG) COMMUNITY FACILITIES DISTRICT (CFD) FEE ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -inside CFD 581473 BUILDING STANDARDS FEE SDCWA SYSTEM CAPACITY CHARGE 5/8" Displacement SDCWA SYSTEM CAPACITY CHARGE 5/8" Displacement SEWER BENEFIT AREA FEES -B SEWER CONNECTION FEE (General Capacity all areas) STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1-Medium BLDG SWPPP PLAN REVIEW FEE TIER 1-MEDIUM TRAFFIC IMPACT Residential Single Family w/in CFD WATER METER FEE 1" Displacement WATER SERVICE CONNECTION FEE 5/8" DISPLACEMENT (P) WATER TREATMENT CAPACITY CHARGE 5/8" Displacement WATER TREATMENT CAPACITY CHARGE 5/8" Displacement Total Fees: $29,219.74 Total Payments To Date: $29,219.74 Co-Applicant: TOLL BROS INC 725 W Town And Country Rd, 200 ORANGE, CA 92868-4709 760-720-5485 Balance Due: $0.00 $2,006.95 $1,292.47 $1,723.10 $66.00 $166.00 $92.00 $182.00 $8,894.69 $20.00 $189.00 $4,840.00 $1,255.00 $899.00 $63.53 $232.00 $55.00 $2,740.00 $362.00 $4,013.00 $123.00 $5.00 ~. ,cr;'ji, { • H , PERMIT INSPECTION HISTORY REPORT (CBRA2016-0021) Pormit Typo: BLDG-Associated Permit Residential Application Date: 12/12/2016 Owner: RANCHO COSTERA LLC -2483 Work Class: Single Family Detached Issue Date: 01/13/2017 Subdivision: Status· Closed -Finaled Expiration Date: Address: 2587 Wellspring St Carlsbad, CA 92010-5604 IVR Number: 778 Scheduled Actual Inspection Status Complete Date Start Date Inspection Type Inspection No. Primary Inspector Reinspection 02/2212017 02/22/2017 BLDG-22 014404-2017 Passed Jonathan West Complete Sewer/Water Service 03107/2017 03/0712017 BLDG-11 015753-2017 Passed Jonathan West Complete Foundation/Ftg/Pier s (Rebar) 0411912017 04/19/2017 BLDG-15 020521-2017 Passed Jonathan West Complete Roof/ReRoof (Patio) 0510412017 05104/2017 BLDG-84 Rough 022160-2017 Cancelled Jonathan West Reinspection Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 05/08/2017 0510812017 BLDG-84 Rough 022588-2017 Passed Jonathan West Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 05/1612017 0511612017 BLDG-82 Drywall, 023450-2017 Passed Jonathan West Complete Exterior Lath, Gas Test, Hot Mop Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-17 Interior Lath-Drywall Yes BLDG-18 Exterior Lath and Yes Drywall BLDG-23 Gas-Test-Repairs Yes 07105/2017 07/05/2017 BLDG-Electric Meter 027917-2017 Passed Jonathan West Complete Release Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 07124/2017 07/2412017 BLDG-Final 029574-2017 Passed Chris Renfro Complete Inspection July 24, 2017 Page 1 of 2 Pormit Type· Work Class: Status· Scheduled Date July 24, 2017 BLDG-Associated Permit Residential Application Date: 12/12/2016 Owner: Single Family Detached Issue Date: 01/13/2017 Subdivision: Closed -Finaled Expiration Date: Address: IVR Number: 778 Actual Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final COMMENTS RANCHO COSTERA LLC -2483 2587 Wellspring St Carlsbad, CA 92010-5604 Reinspection Passed Yes Yes Yes Yes Yes Complete Page 2 of 2 ii'> ~ CITY OF CARLSBAD Building Division 0 INSPECTION RECORD CARD WITH APPROVED 1 ·,"LANS MUST BE ICEPT ON THE JOB 1 ....... CALL BEFORE 3:00 pm FOR NEXT WORK DAY INSPECTION 0 FOR BUILDING INSPECTION CALL: 760-602-2725 DEV2016-0039 PC2016-0007 2081903400 1/6/2017 CBRA2016-0021 Required Prior to Requesting Building Final If Checked YES Planning/Landscape 760-944-8463 All ow 48 hours CM&l (Engineering Inspections) 7 60-438-3891 ca·u before 2 pm Fire Prevention 760-602-4660 Allow 48 hours Type of Inspection CODE t; BUILDING Date Date Inspector #11 FOUNDATION '3-7-/7 0 ELECTRIC UNDERGROUND O UFER #12 REINFORCED STEEL !JOUGH ELECTRIC #66 MASONRY PRE GROUT ELECTRIC SERVICE O TEMPORARY 7-,~ I 1 ) OGROUT 0 WALL DRAINS ,,,10 TILT PANELS #35 PHOTO VOLTAIC #53 ELEC/CONDUIT/WIRING #11 POUR STRIPS #39 FINAL #11 COLUMN FOOTINGS #14 SUBFRAME O FLOOR O CEILING #15 ROOF SHEATHING #13 EXT. SHEAR PANELS #16 INSUlATION #18 EXTERIOR LATH #17 INTERIOR LATH & DRYWALL #51 POOL EXCA/STEEL/BOND/FENCE #82 ·DRYWALL,EXTLATH, GAS TES (17,18,23) t;· I b- #55 PREPL.ASTER/FINAL #83 ROOF SHEATING, EXT SHEAR (13,15) #19 FINAL #84 FRAME ROUGH COMBO [14,24,34,44) 5 ~ i • I CODE ,; PLUMBING Date Ins ector #85 T-Bar(14,24,34,44) #89 FINAL OCCUPANCY (19,29,39,49) ~~~~~~--'-:---,-~-,-',:--~-+-~~---:=-t--~~~~-1 .wi:~ FIRE Date Ins ector A/5 UNDERGROUND VISUAL A/S UNDERGROUND HYDRO A/S UNDERGROUND FLUSH A/S OVERHEAD VISUAL A/S OVERHEAD HYDROSTATIC A/S FINAL CODEii STORMWATER F/ A ROUGH-IN #600 PRE-CONSTRUCTION MEETING F/A FINAL 3 FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN ... ~5 NOTICE TO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST 1t607 WRllTEN WARNING FIXED EXTINGUISHING SYSTEM FINAL #609 NOTICE OF VIOLATION MEDICAL GAS PRESSURE TEST #610 VERBAL WARNING MEDICAL GAS FINAL REV 1012016 SEE BACK FOR SPFCIAI NOTFS Michael Baker INTERNATIONAL March 30 , 2017 City of Carlsbad Building Department 1635 Faraday Avenue Carlsbad, CA 92008 Subject: Inspector: Vistas -Lots 164,165,166, 188, 189, & 190 City of Carlsbad Tract No. CT 13-03 JN 143824 Michael Baker International has performed a field survey on March 29, 2017 to field check the building footing forms for Lots 164-166 & 188-190 on Wellspring Street. The results of the field survey reveal the footing forms to be within substantial conformance, both horizontally (0.1 O'±) and vertically (0.05'.±) with the City of Carlsbad approved precise grade plans DWG 480-3C, dated February 9, 2016. Sincerely, Tim Thiele, P.E. Project Manager H:IPDATA1143824_R0BERTS0N RANCI-MDMINICORRESPNDNCIFORM CERTS\TOLL BRO_FORM_PA6_CERTD9_164-166_1B8-190.DOC PLANNING • DESIGN • CONSTRUCTION SOSO Avenida Encinas, Suite 260, Carlsbad, California 92008 # 760.476.9193 # FAX 760.476.9198 Offices located throughout the Country • www.mbakerintf,com Southwest Inspection and Testing, Inc. 441 Commercial Way, La Habra, Ca 90631 (562) 941-2990 • (714) 526-8441 • Fax (562) 946-0026 $WIT Job No. REGISTERED INSPECTOR'S DAILY REPORT Is D ·"!:>( <-- TYPE OF INSPECTION REQUIRED Job Addres Job Name Reinforced Concrete Post Tensioned Concrete Reinforced Masonry Material Description (type, grade, source) D D D Welding Fireproofing Asphalt Tract No. Contractor T o L iL . Subcontractor~~( TESTS PERFORMED AIR CONC WATER TIME SET# TRUCK# TICKET# SAMPLE LOCATION SLUMP TEMP TEMP ADDED CAST MIX # D D D REMARKS INSPECTION SUMMARY-LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS, ETC. INCLUDES INFORMATION ABOUT -AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER, TYPE & IDENT. NO'SOF TEST SAMPLES TAKEN: STRUCT. CONNECTIONS ELD MADE H.T. BOLTS TORQUED CHECKED, ETC. CERTIFICATION OF COMPLIANCE CONTINUED ON NEXT PAGE 0 PAGE __:L OF,. TIMEIN TIMEOUT SAMPLES fo~ ( 4-- Approved By 'ft '"101 A-v'~ AGENCY Project Superintendent White -Office Copy • Canary-Accounting Copy • Pink -Inspector's Copy • Goldenrod -Jobsite Copy SITI F-049 ©Southwest Inspection & Testing, Inc. 'Project Name: . -- Location: : Soil Engineer: Initials: Y£SL- Date: Lf{'-1[~1 Initials: ~ . Date: Lt/4{7.0l, Initials:~ Date: '-t/ Ll{ ~, Initials:~ Date: 4/ 4/ Z.O l1 Notes.: · Geolog'ist gaJ,t · Project No.: Date: -~q--q1~, Report No.: Author: Day: (circle one) t«'S'. UA:mm!S ~ T W T -F S S other:. ____ _ · Pennit No. Observation Summary: C. BR.~ 2.tl t.o -00.,, I) -Ot,'i -. · ... · oot..._- .. OCD 'SO -60 '"'\ A representative of LGC Valley, Inc. ob$0rved the on-site ·soil conditions. The soil conditions at the site are substantially in conformance with those assumed in ·the geolechnical report. A representative of LGC Valley, Inc. ob~rved the footing excavation(s). The footing excavatlon(s) extend. into the proper bearing strata and are in general conformance with the recommendations of the geotechnicaf report. .A representative of LGC Valley, Inc. measured the footing setback from the slope face. The setback was in genera·r accordance wlth the recommendations of the geotechnical report. o~;~f't..IQ :ft~~t.!'~~ in~:< b«d.{,·~ 1. Footing excavations sho.uld be cl~ane(i of loose debris a.nd thoroughly moistened just prior to placing the .concrete. 2. Based on the expansion potential of the underlying soils, presoaking of soil below slabs may be recommended. Consult the · geotechnical report for tt:ie preso~king recommendations. We note that clayey soils may take an e~ended period of time and the contractor should schedule accordingly. 3. In the event of a site change subsequent to our footing observation a.nd prior to concrete placement {i.e. heavy rain, a .construction/placement delay, etc.), we should be contacted to perform additional site ob$ervations, as necessary. . 4. Line and grade of .the footing excavation(s) are not part of th~ purview of LGC Valley, Inc. 5. Soil compaction test results, including depth of fill, relative compaction, bearing values, and soil e~pansion index test results are contained in the As-Graded Geotechnical Report provided at the cotnpietion of grading. 4th [l Cwwwb,. . 'lt'-t{z.on _1_.D _ ____,~ Fo~ r Date Technician Hours FOOTING OBSERVATION SUMMARY Received by; Print: White -File Copy Yellow-Client Copy LGC VALLEY, INC. Geotechn.ical Consulting Pink -Fielcl Copy Gold -Client/Agency Copy