Loading...
HomeMy WebLinkAbout2600 CARLSBAD BLVD; ; PCR13056; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 05-06-2013 Plan Check Revision Permit No:PCR13056 Job Address: Permit Type: Parcel No: Valuation: Reference #: PC#: Project Title: Applicant: Building Inspection Request Line (760) 602-2725 2600 CARLSBAD BL CBAD PCR Lot#: 0 2030510300 $0.00 CB122104 Construction Type: 58 ARMY/NAVY: INDOOR BLEACHERS AND PREFAB TRUSSES FOR ATHLETIC FACILITY Owner: Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: ISSUED 04/25/2013 JMA 05/06/2013 05/06/2013 KEVIN HALLOCK ARMY&NAVY ACADEMY CARLSBAD CALIFORNIA 1-619-557-0575 Plan Check Revision Fee Fire Expedited Plan Review Additional Fees Total Fees: $435.00 Inspector: PO BOX3000 CARLSBAD CA 92018 $435.00 $0.00 $0.00 Total Payments To Date: $435.00 Balance Due: FINAL APPROVAL Date: Clearance: _____ _ $0.00 NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government.Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to pro\est the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which.vou have oreviouslv been aiven a NOTICE similar to this or as to which the statute of limitations has oreviouslv otherwise exoired. ~ «1~ ¥ CITY· OF CARLSBAD PLAN CHECK REVISION APPLICATION 8-15 Development Services Building Division 1635 Faraday Avenue 760-602-2719 _www.carlsbadca.gov Plan Check Revision No. flt:-~ 3o5"v. Original Plan Check No. C(b I Z b I ¢L/ Project Address ~& CD CP(l_L5 ~D . \?L---'VD, Date 4--IS--I~ Contact I~ ~v <. V'\ ~ o-1 \ c:>c___,LL-Ph q l 0 -Ll,t'7.--ttl '?)1:..--Fax --------- ' Email l<--ev < v\. (-\-o.J locJ_e-: @., ~05 e--a Vlp. . dad~ e , c:_6VV\ Contact Address l 9, ,z.,9 µ...Q.._\A c.oc..JL-. ;zt · . City S • D , Zip G\:1 . .,ll9_ General Scope of Work_· __,A~~-'--, _le..=-'-~~C~_Fi_, _c:t._c_=-'_< _\\_l__,~"",_i ___________ _ I Original pl ans prepared by an architect ot engineer; revi$ions must be signed & stamped by that person. 1 . Elements revised: ~ans D Calculations D Soils D Energy D Other __________ _ 2. 3. 4. Describe revisions in detail List page(s) where List revised sheets each revision is shown ·e:>u..+drov.<S~vb· t5q;0\p, ~ ~~. I V I I ~.e\/(L~\' ~ u;cX.Q_ v-0-.' (ls ~~-e~--u " 5. 6. Does this revision, in any way, alter the exterior of the project? D Ye,s Does this revision add ANY new floor area(s)? D Yes , fZf No 7. Does this revision affect any fire related issues? o· Yes fil-No 8. Is this a complete se.t? ~s . ,D Nq . · ~Signature.~, . that replace existina sheets '@-No · 1635 Faraday Avenue, Carlsbad, CA 92008 fh: 760-602-2719 &lx: 760-602-8558 frnait building@carlsbadca.gov www.carlsbadca.gov · EsGil Corporation in a?artnersliip witli qovernment for (}3uiCaing Safety DATE: MAY 06, 2013 V.PPLICANT ,r .,URIS. JURISDICTION: CARLSBAD D PLAN REVIEWER D FILE PLAN CHECK NO.: 12-2104 (REV. #4) -PCR #13-52 ____ SET: II PROJECT ADDRESS: 2605 CARLSBAD BLVD. PROJECT NAME: ARMY /NAVY ATHLETIC FACILITY & PRESS BOX BUILDING C8J The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith Will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have si·gnificant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: Kevin Hallock C/O HOUSE & DODGE DESIGN 1929 HANCOCK ST., #200, S.D., CA 92110 C8J EsGil Corporation staff did not advise the applicant that the plan check has been completed. D EsGil Corporation staff did advise the applicant that the pla!1 check has been completed. Person contacted: Kevin Hallock Telephone#: 619-557-0575 Date contacted: (by: ) Email: kevinhallock@houseanddodge.com Fax #: 619 557 0577 Mail Telephone Fax In Person ~-REMARKS: The outdoor sports equipment & Elevator guide-rails (deferred submittals are under this plan change). By: ALI SADRE, S.E. EsGil Corporation D GA D EJ D PC 4/30 ,, •' Enclosures: 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 EsGil Corporation In <Partnersliip witli fio1J~rnment for <.Bui(aing Safety DATE: APRIL 22, 2013 9-A-P.i=>·b~NT ~-JURISDICTION: CARLSBAD D PLAN REVIEWER D FIL_E PLAN CHE;CK NO.: 12-2104 (REV. #4) -PCR #13-52-'-·---SET: I PROJECT ADDRESS: 2605 CARLSBAD BLVD. PROJECT NAME: ARMY /NAVY ATHLETIC FACILITY & PRESS BOX BUILDING D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are-resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. C8J The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check 'list has been sent to: Kevin Hallock C/O HOUSE & DODGE DESIGN 1929 HANCOCK ST., #200, S.D., CA 92110 D EsGil Corporation staff did not advise the applicant that the plan check has been completed. iZ] EsGil CorporQtion staff did advise the applicant that the plan check has been completed. Person contacted: Kevin Hallock Telephone#: 619-557-0575 Date contacted:'-f b .. (by: y..a.,)Email:kevinhallock@houseanddodge.com Fax #: 619-557-0577 tMail/ Telephone Fax--J In Person iZ] REMARKS: The outdoor sports equipment & Elevator guide-rails (deferred submittals are under this plan change). By: ALI SADRE, S.E. EsGil Corporation D GA D EJ O PC Enclosures: 4/18 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 CARLSBAD 12-2104 (REV. :/#4) -PCR :/#13-5'2 APRIL 22, 2013 • Please make all corrections, as requested in the correction list. Submit FOUR revised stamped & signed sets of plans for commercial/industrial projects. For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. 1. The following. design loads shall be clearly indicated on the construction documents. (Section 1603.1 ): • Wind load. The following information should be provided, (Section 1603.1.4) o Basic Wind speed (3-second gust), mph o Wind importance factor, I, and building category o Wind exposure o Applicable internal pressure coefficient o Components and cladding (the design wind pressure in terms of psf to be used for the design of exterior component and cladding materials not specifically designed by the registered design professional • Seismic design data. The following information should be provided. (Section 1603.1.5) o Seismic importance factor, IE and occupancy category o Mapped spectral response accelerations Ss and S1 o Site class o Spectral response coefficients Sos and S01 o Seismic design category o Basic seismic-force-resisting system(s) -See Non-Building Structures. o Design base shear o Seismic response coefficient(s), Cs o Response modification factor(s), Rp o Analysis procedure used. 2. Note on plans: Special inspection will be provided for the following. (Sec. 107.2): a) Steel construction. Special inspections for steel elements should be provided in accordance with Section 1704.3 and Table 1704.3. · b) Concrete construction. Special inspections and verifications should be provided in accordance with Table 1704.4: CARLSBAD 12-2104 (REV. #4) -PCR #13-52 APRIL 22, 2013 3. A Statement of Special Inspections, prepared by the registered design professional in responsible charge, shall be submitted. This statement shall include a complete list of materials and work requiring $pecial inspection, the inspections to be performed and an indication whether the special inspection Will be continuous or periodic. Section 1705. 4. Please provide structural calculations for the submitted package. 5. The foundation plans need to be stamped by the project engineer indicating they have been reviewed and no exceptions are taken. , 6. The jurisdiction has contracted with EsGil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact ALI SADRE, S.E. at EsGil Corporation. Thank you. CARLSBAD 12-2104 (REV. #4) -PCR #13-52 APRIL 22, 2013 [DO NOT PAY -_THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: CARLSBAD (REV. #4) -PCR #13-52 PLAN CHECK NO.: 12-2104 PREPARED BY: ALI SADRE, S.E. DATE: APRIL 22, 2013 BUILDING ADDRESS: 2605 CARLSBAD BLVD .. BUILDING OCCUPANCY: B/Sl/ A4/ AS BUILDING PORTION outdoor sports ·equipment elevator · guide:-rails Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code CB Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: D DRepetitive Fee L •"" I .Repeats • Ba.sed on hourly rate Comments: AREA Valuation ( Sq. Ft.) Multiplier ·- By Ordinance Complete Review D Other 0 Hourly EsGil Fee TYPE OF CONSTRUCTION: V-B/SPR. Reg. VALUE ($) Mod. $435.001 D Structural Only 31 Hrs.@* =====$=11=6=.o:o $348.001 Sheet 1 of 1 "1· t 4 _3_ 1-------------WIDTH-------------1 Addtional display area consisting of signs, arches, message centers or video above or below the scoreboard. (see sheets 2-4) for colum.n and pier sizing) 2 1 Rev Dim ''B_" §'. 1' I 8' D "' '"' "' '""" '" '''""" ,, """" "'"" "' "" ,7 .!L_jn _8' C SCOREBOARD HEIGHT 15 2013 ClTY OF CARLS~AD BUILDING OIVl~ION Bl Check electrical prints to determine conduit sizes (must meet code) A .6'' From end of column to edge of co~1crete 4 l,,l----1-----"B"-. -------1-1 I I 'I I I i.Ut• I l :A:pprox:. I I ,:(fuot,tori:C615 I 1. 1row~@ll~~ I· I ~componentµ I 1 Steel Column I I (see sheets 2-4) I I . I I I I Concrete nm$t slope\ I i away from columns I I I ~-~ Pier Depth (see sheets 2-4) _J Coarse aggregate concrete (fc = 2500 psi) I .. [ Pier Diameter (see sheets 2-4) fRONTVIEW 3 Overall Display Height,i.---=s=--+----+----+------'1---------'1--~--+-----i 482 I I I 420 522 4' 10' NIA 590 4' 10' Dim"A" Dim "B" C 4' 8' 4' . 10' 18' 10' 6 9/32" 592 4' 10' _L6' 10' 3/16" 490 N/A 4' 8'. General Notes; 1. Colu11m steel to be grade A992 (50 ksi steel minimum). 2. Bracing steel to be ASTM A500 Grade B mininmm (see note 2 on sheets 2-4' 3. Minimum bolt grade: A307 4. All welds to conform to AWS standards 5. The dimensions in the charts on sheets 2-4 are calctllatecl using the requirements specified in ISC 2009, and the Manual of Steel Construction (13th E'dition). Soil lateral bearing pressure is considered to be 150 psf/f. 6. Toe weights of signs to be calculated using 4.3 lb/ sq. ft of sign area. 7. The weights of Nevco message centers to be calculated using 8.5-lb/sq ft. 8. The weights of Nevco video displays to he calculated using 9.5 lbsj'sq. ft. 9. The weights of Nevco arches to be calculated using 7 :7 lbs/sq. ft. Important. Read before installation. This is not an engineered drawing. It is intended for representational purposes only. The dimensions call~d out on this drawing are intended to be used as a guide only, and are not intended to be suitable for all conditions. Adding signs or other components around the scoreboard beyond the scope of this drawing or increasing the display height from the ground will affect the installation requirements. Nevco recommends that you consult a professional engineer or architect familiar with the area before attempting installation. They can verify that the selected mounting beams.or posts along with the brackets, screws, and other hardware items· provided by others or Nevco are adequate for your local soil conditions, wind loads and other local codes. If procedures are used that are not covered in this drawing, careful analysis o: the installatiorn,;_i;;;.s_u_rg,<.ed.;.c._. __________ -.----------------i Urawn 2 Outdoor Scorel:)oard .Installation 2 Column Dale DBB •11ilnEvca 'A .... ~ ... -----~ .!" r -'7 ' 2-~ ( @X:RO'.Sl:LRE~c~(se--e·'rrore~J} "" ( I '9I)~Ff'W::FND-1BONBS'I J 1~ y : RF~-,--~ . .... I Rev! ,. : { \ : ~ I ' 'I l --: .... ·: '. ' ' ,; " ' : I ' I , • ,,: l. • ' •• ' ~ : _J ~ '~~ ~ I - Column and 1-'Ier Kea11 Irements !tsasea on A:S( ;t: 1-vo E;_~oooore li-ror,.,, _,.,11 vvmd Load) Column .sQd Pier 8€auirements (Based on ASCE 7-05 Exposure B for 90mph Wind Load) ,DIso1av HeIant _pi .. ,· ,,. r,er ue "U<1 • jCll. I enc .m...-"'"' :n111m Rb,..,,; r."'1.,rr,n -~,;~~·H~ Pier Dia Pier Depth Col. Len. Unbraced Col Braced Column , 6' 2' 1-n,·' --~ W10x22 -r,,mx18-' 6' 2' 7'6" 23' W8-x 18 W8 X 15 / 8' 2' 9'6" 27' W12x26 W8x21 '\. 8' 2' 8'6" 26' W8x24 W8 X 18/ 9' I ·2· 10' 28'6" W12 x30 W10 x22 "H' 2' 8'6" 27' W8x24 W8 X1K D I !:::l Cl.) 10' I 2' 10'6" 30' W10 x33 W10 x 26 Ci:l(I.) ll\' 2' 9' 28'6" W12x26 W8v~1 0Z 10' 6" 2' 11' 31' W10 x33 W10 x26 0Z 10'6\. 2' 9'6" 29'6" W8x28 W8z.21 -0 -0 :S:b 12' 2' 11'6" 33' W10 x 39 W12 x26 ~~ 12' "\. 2' 10' 31'6" W10 x33 WUIX 22 ~:s 14' 2' 12' 35'6" W14 x4.-:i W12 x 30 &1-1 14' \. 2' 10'6" 34' W8x35 VIVl0 X 26 ~~ 11':' 2' 3' 13'6" (11,' . 39' (36'6~) W10 ir.t1.o W14x~ ~~ 16' \ 2' 11' 36'6" W12 x40 w12x 26 18 2' 3' 14'6" (11'6" 42'6" 39'6") W12 x53 W18 x~'> (;t. l-18 \. 2' 3·· 12' {lU) 4V ·tvOJ W10 x45 J'W12 X 30 Cl:) Cl.) 20 2' 3' 16'6" (12'6") 46'6" (42'6") W12 x65 W16 X 40 ~~ 20 '2' 3' 13'{11') 43' (41' W10x49 / W14X 34 .-.z 22 2' 3' 17'6" (14') 49'6" 146' .. W12 X 65 W21 x44 22 ~3· 14'(11'6" 46' 43'6") W10x60 , W18 x 35 ,_, 25 2' 3' 19'6" C 15'6"} 54'6" 50'6") . W12 X 79 W18 X 50 25 2' ~-10· (1~1:;1' ol (4/o 1 W12x65 /. W16x 40 - 30 ··~-~-"'·' IHfl Ov ~OJ -W24x104 W21 x55 30 2' :s 100· (14'o 1 ::io·o lb4o J W12x87/ W16x 50 nr --~ ;:, ~ . ' " /1 o _.,.fL:"I r" ~n W?1 X68 35 2' 3' ,.\, 21' (16'6") 66' 61'6") W12x Hf6 W21 X 55 .. ,_ 40 1 2' 3' 29'6" {Z3' 79'6" 73' W14 x 1 q.:, ~ W24 x-16 40 2' 3' I\. 24' (18'6"1 .74' 168'6"l W14 xA20 W21 x 62 , ~ Column and Pier HeqUirements (Based on ASCE 7-05 Exposure C for 90mph Wind Loadl Column and Pier ReqwremeNS (tjased on AS(.;t: 7-05 Exooswe B·for 90mph Wind Load ri11~ u1s01av He1a11t Pier oii::i 1-'ier Deoth l 01 Lenath itrnl5r-ac,:,'i-f:r:-ni,-rm·n: -Hr1>1-;:,r1,r,:nu:.-m·n,. ~l u1so1av He1unt Pier ni::i 1-'ter ,.., tn • L;o1 Lenatn ili.lnb·race<:l'.C&ffmr'l1 1Braeee'Co1Ci'riin~i ~0 5' 2' 7'6" 22' W8 X 18 "\ W10 X 17 ./ ~I 5' 2' 6'6" '-21' , W8 X 7H W8 X 13 ~e=l . 6' 2' 8'6" 24'' W8 X 21 '\. W8 X l!Y' ~1 6' 2' 7' ' 22'6" W8 )(18 W10 X 15 , H:S -· L '1NA x ~ ::i 7' 2· 7'6" , 24' WK"x 21 wrn·x 17 C ' r=lj;,.:i r ·x • 2' 9' 26'6" W8 X 24 '-W:M21 !...:i 8' 2•· 8' . ~5'6" w10 x 22 W8x 18 ~~ , l'1'0'., f2'l :ro'., ,29'6~· {1)\(4'0cx7'33\ ,'ill'~:x"221 ·1 ~ 1t0·,. '2'· 19'.< l?IH'.n~I /:YY.X~'2l!. /W,or 'l8! io,~ '---1?'-~ 2' 11_· --~2'6" W8 x 3"-. l 111 10~ 26 .. (/J 12' 2' 9'6" 3'1.' / W10 x ::\3 W10 x 22 c;i::5 74' -~ ,_ 1ro ~ .:.--v,-~.~s-/W12X""" Jo'f=i 14' 2' 10' 33'6'\. i/ W10x33 W10x22 , 16' 1 2' 3' 12'6"110'6"1 38' 6'1 W14x48 i/ W12x3o,,, _ 16' 2' 11' 36'6"'\.i W10x39 W10x26 · '""'\... l.t!ILimn.and Pier Heauirements !tsaseu•'On~ ~ :kxoo~•-; tor~ u,mn v= Loam • t;oiumn ano t'ter Heau1rements !l-3asec .on =c ,._ 1-n!-> t:xoosure l:l or mnn vvma Loa fxl ~ Disoll!l'rrtek, .-i ·~· 'Uia e· , :01 Len n Unbraci,,-n •~lumn racea Column* , r:l (IJ 1J1s01av Hetant Pier Dia Pier Denth CarLennni Unbraced Column Braced Column.* o 5' z 7' 21 '6" W8 x 1 R w1 o x 15 o ...l 5' ?' n' / 20'6" wa x 15 wa x 13 · ~ S.: ;:i! 8' 2' 8'6" 26' W8 X 24 W8 X 18 §:' :;;'J 8' 2' 7'6" 25' '\. W8·x 21 W8 X 15 :<;:t-·::--t; 10' 2' 9' 28'6" W12x26 WBx21 -~ 10' 2' 8' / 27'6" '-W8x24 W8x18 '~z 12' 2' 10' 31'6" W10x33 W10x22 ~~ 12' 2' 8'6"/ 30' 'W12x26 W8x18 ..... 15' 2' 11· -:ii::• W10x39 W12x26 15' 2' 9'i" 34'6" Vik10x33 wrox22 · column-and t-ier HeQuirements {Based on A:sCE 7-05 Exoosure C for 90moh Wind-Load) Column and.Pier Requiremenpf'(Based on ASCE 7-05 Expo~re B for 90mph Wind Load) • u1s01av ne ... , '" Pier ni::i r-1er ueom L;0tLenau , llnh==d r.niumn l-3raced ;njr •mn• Disolav Heiaht Pier Dia PierAJeoth Column Lenath Unbraced'Colum Braced·Coltimn ~ f:q~ 4' 2' 6'6" 20' WSx 15 W8 x1::i (il~ 4 2 · /5'6" 19' W8x1~ W8x~3 8...:i 5' I 2' 6'6" 21' wax 1s W8X13 O.,.:i ~~ 6' 2' 7' 22'6" wax 18 W10x 15 §: ~ 5 2 / 6' 20'6" W10 x 15\.. W8x13 -R 2 R' 21'R" W10 x 17 \.. ws·x 13 B ~ ~ (/) 8' 2' 8' 25'6" W8x 21 W10 x 17 -Cl.) S!~ ~15 8 2/ 7' 24'6" WRx 18 W12 X 14 10' 2' 8'6" 28' W8x24 W8x18 10 z 7'6" 27' W8x21 \.. W10 x 17 12' 2' 9'6" 31'6" W12x30 W8x21 15' 2' 10'6" 35'6" W8x35 W10x26 12 /2' 8' 30' W8x24 '-W8x18 11> / 2' g• 34' W10x'-l'-l \.W8x21 : L01Umn and t-ier HeauIrements itsasea on AS( ... t-,,., t:xoosure (j tor,., mnn vvino Loa Displav Height Pier Dia Pieruepth Col Lengn Unbraced Column Braced Column • 1.,;oJumn anoFIer Reau1rements ,...,.sea on ~St:t: 7-0b 1-vnosure ts tor ... •mon. vvma Loam ~~ 3 2' 5'6" 18' W8x 13 wax 13 fxl ~ Displa\ Hj'lght ·Pier Dia Pier Depth Col LenQth Unbraced Column Brac~olumn• 9~ 6 2' 6'6'' 22' wax 18 W8x 13 e~ 31' 2 5' 17'6" W8x1::l W8~13 ~~ 8 2' 7'6" 25' W8x21 W8x15 ~t3 .,.; 2 6' 21'6'' W8x15 W8 X \.3 coz 10 . 2' 8' 27'6" W8X24 W8x 18 co~ / ~ ? R'h" ?4' W8x 18 Wf x1'.\ -12' 2' 8'6" 30'6" W8x28 W8x 1R / 10 2 7' 26'6" WR x21 W1 lx1~ 1n' -· 2' 9'6" 34'6" W10x33 W10x22 /' 12 2' 7'6" ~·sn W8,X24 W1 } X 17 '- I 15 ?' 8'6" 33'6" W8x28 Wl x18 .. Chart Notes: L If the display height is between chart values shown above, use the next highest value. 2. * Requires that braces be placed approximately 10' from ground level spa11ning both columns. If ~1-nEVCD display is taller than 20' place braces on ·10' spacing. Outdoor Scoreboard \ 3. Wind loading figured at!Eliposure~"c"··.,;·openyterra'iillwith scattered o.bstructions having heights Instaliation A generally less than 30 feet. This category inch.ides flat open country, grasslands, and all water surfaces 2 Column Nevco .. Inc~ in hurricane prone areas. Greenville, Illinois 62246 4. Wind loading figured at~~ ''B!•~.:·u;:!l>~ antf'sulfu:rbari-ai:eas\ wooded areas, or other terrain Drawing-No. 241-0347 with numerous closely spaced obstructions having the size of single-family dwellings. or larger. These If/ areas prevail in the upwind direction for a distance of2600 feet or 20 times the structure height, Orawn !_Date 8/6/12 Sheet of whichever is -e:reatcr. DBB · 2 9 "" ll. D C B A _'± 3_, 2 l, Row Scoreboard / Dimensions must be increased by an l'lffiOUnt equal to the additional column length when installation consists of additional display components above the scoreboard. (Includes dimensions for welded or bolted option.) r--------------1-,----/'.,. -.. I I I I I I I r---' 7/ 6" di l 1 21/." I 1 , 1 ameter ho es I ;1· 1 I/ centered on <::olumns -··-Scot(:board -·-· 1650 1610 1620 3650 1625 1632 3602 Dimensions to top of brackets for WELDING option Scoreboard Height Dim "C" (Welded) 3' 3/32". 31 7/8" 4' 3/32" 43 7/8" 51 3/32" 55 7/8" Dim "D" (Bolted) 35 5/32" 47 5/32" 59 5/32" option See notes/clra'wings OI'l sheets 8,9 including bracket orientation, Jateral installation (if required}, wind speed requirements, etc. Hardware su=lied bv· t irhers Description Quantitv 3/8 X 1 1/2 Bolt" 8 3/8 Flat Washer 16 3/8 Lock Washer 8 3/8 Nut 8 3/8 -16 Eye Bolts** ·• Minimum bolt grade is A307 **see sheet. .8 l Rev Outdoor Scoreboard Installation --i1iinEVCD 2 Column Nev.co, Inc. Greenville, Illinois 62246" Drawing No. 241-034 7 Drawn DBB Date 8/6/12 Sh~'t:I of 5 9 4 3 2 1 D C B A _'-1 a 2. l Rev· and''M"J All brackets oriented 12,7,,0\V'SC'OREBO»'.RDl tf Dimensions mustbe increased by an amount equal to tl1e additional column length when installation consists of additional display components above the scoreboard. (Includes Dim "F", "'G" 1------------1-~ --(- DI I I ! r-2~.. 7/16" diamet:::::------,. ~Topofs~oreboard I -----~-"?½ centered.on columns'\. 3~16" ~.,......,.-,-(flush with to!' of column) as shown on columns ID C Bl ~/7777. .. / 7TT;Z"7'777TT7'"77'~ Dim "B'' Dim"B" I I '-Bolt brackets to columns (see sheet 2) ush1g (2) 3/8 x 1 1/2 bolts nuts and washers. -supplied 'by o,thers -Minimum !!:racle: A307 . WELDING DIMENSIONS BOLTING DIMENSIONS Scoreboard Height Dim"C" Dim"D" Dirri"E" Dim"F" Dif(l "G'' Dim"H" 6' 3/16" 19 7/8" 241/8" 6715/16" 23 5/32" 27 7/16" 71 1/4" 8'3/1fi" 43 7/8" . 481/8" 91 15/16" 47 5/32" 51 7/16" 951/4'' 5' 3/16" 31 7/8" 361/8" 5515/16" 355/32" 39 7/16" 591/4" . Weld 3" side to column (lateral extends 4'' away from column) Weld TS4x3x 3116 1n1eral to fronr and back {Opllonal to rc~lut;e required colu,nn s,zo. Sheet 2-,1 designates wiU\'·') FRONT VIEW NOTE:: Minimt\m bolt ,.--- A I) I II ;:so:,:, I 3658 ' 1 T 1 Q F/H" I' '~4 1 /H" I H./' l h/1 h"" I 235/32" 27 7/16" 71 1/4" Required Hand Tools: j I 1 '.5634, I i.v tJ/0 I u~,• ,;:s~ .. ,,1~·-1 . I 1;:io\ 1'/C::S'"l I tO'I• 1,0/•l·O"l I ,3·5-5/,32"! I !39'7/r6"i 1Tr::r,~·-I ~.~ii I ,~:.x::~.~= I ~,~.:::~: I .~~--::-:~-=-l--:-~---;-.~=.-:~-,~~:-:-1:--------=-+:---==---1:--=~=--l: i·.~::~:::::;.:v. 1. Phillips head screw 6' 3/16" 437/8" 48 1/8" 6715/16" driver/drill with phillips driver. 2. 9 / 16" wrench I ~~!~ I 8' 3/16" I 43 7/8" I 481/8" I 9115115·• I 3. '.Ratchet wrench and 9/16'' socket 4. Level 5. Tape measure [ ,.,.,..,.,.,.. I 9' 3/16" I ,-43 7/8" I 481/8" 110s f5!16" I 47 5/32" 51 7/16" 47 5/32" I 51 7/16" I 47 5/32'' ] 51 7/16" I 71 1/4" 951/4" 107114" needed· if installer uses weldinj! opJ;ion. HARDWARE SUPPLIED BY OTHERS Quantity. Hi 32 16 16. 2 -·c 13 Notes; 1) If welding brackets to columns, According to !BC standards, all welds are to be performed by AWS certified welder. The city in which the display is installed may waive this standard. Contact local officials if Al necessary. Outdoor Scoreboard Installation ~1tlnEVCD A 2) FOR HIGH WIND AREAS: For installations in wind zones higher than 150 mph, brackets must lJe welded to columns, 3) Dimensions above should be taken from the top of the SHORTEST column, marked and leveled across to other column. 4) Brackets shipped in sepa1'ate container. 4 3 2 Column Drawn Dale DBB 2 S/6/12 Nevco, Inc. " Gxeenville, llliuois 62246 Drawing No~ Sh~-ct of 6 9 241-0317 1 4 ;i_ 2- Re:v 3 Row Scoreboard r L' Dimensions must be increased by an antount equal to the · additional colu~n length when ipstallation consists of additional r--------11--7 display comp·onents above the scoreboard. (Includes l I I / dimensions for welded· or bolted option.) ( ' DI I I I I I I I 12 reet Equal , ..] (typical for all models below) I I ; C'' B H-+-----------Din1 "B"---------------1 Model# 16Hi 7604 7614 7624 7680 Welding Dimensions Only 9650 Model# Dim"C" Dim"D" Dim"E" 'Dim"F" 'Dim"G" 1615 19 7/8" 24 1/8" 5515/16" 60 3/16" 1/16" 7604 Al I 7614 I 25 7/8" I 303/32" I 7315/16" I 78 3/16" 7624 122 1/16" 7680 9650 I 19 7/8" I 24178" I 67 15/16" I 72 3/16" 116 1/16" 4 3 I I See notes/drawings on sll'eets 8, 9 inchtding bracket orientation, lateral installation (if required), wind speed requirements, etc. Hardware Supplied by Others Dim"H" 235/32" 295/32" I 23 3/16" ,- Description I Quantity 3/8 x 11/2 Bolt* I 24 3/8 Flat Was.her 48 3/8 Lock Washer 24 3/8 Nut 24 3/8 -16 Eye Bolts0 ·k Minimum bolt grade is .A307 **see sheet 8 Bolted Dimensions.Only Dim"I" Dlm"J" Dim"K" 2713/32" 59 1/4" 63 1/2" 3313/32" 77 1/4" 81 1/2" 27 7/16" 71 1/4 75 1/2" Dim''L" 83 3/8" 125 3/8" 119 3/8" Outdoor Scoreboard lnstallation ~lilnEVCD 2 Column Nevc:o, Inc. Greenville, Illinois 62246 1>,'awingNo. 241-0347 Drawn DBB Date 8/6/12 Shl'l:'I 7of 9 2 D C B 'A D C B A ..,. ;l 2 l 3/8 x 1 1/4 bolts, nuts and washers (supplied by Nevco) Threads: 3/8" -16'\@) _,,.-_ ~ "9]3imum Slide bottom bracket up and tighten one bolt to hold in place 3/8 x 1 1/4 bolts, nuts and washers (supplied .byNevco) Install 3/8 x 1 1/4 bolt ancl 11ut {no washer) in center hole _of top brackets. These will seive as hangers during installation. (supplied byNevco) WARNING: Stack up to 3 washers tµ1der eye bolt if longer than+"· DETAIL E Replace access doors when finished making connections Do riotleave any screw locations empty. Screw sections together front and back using screws supplied by Nevco Make signal-connections between board sections before installing scoreboard. {connections located behind access doors with "SPLICE Install 3/8-16 eye bolts into top of-board {lower 1·ow of cabinets 1st} for lilting. (eye bolts and washers supplied by others) [J DETAIL C ENCLOSURE" label} Secure connections to hangers located inside -cabinets. CABLE HANGER I · I I \ lnse;'t exten_ded t1ange into matmg section (make sure both flanges of male end go to inside of female end) Notes: 1) Signal connections from lower row of cabinets to upper row should be made after both rows have been installed on columns. (see sheet 9 for more details) 2) Make sure all bracket bolts are tight before installating scoreboard. Rev D C B I=portant: Screw sections together prior co installing board onto columns. {Upper row of cabinets, and lower row of cabinets do not connect) Outdoor Scoreboard Installation 2 Column ~iii nEVco 'A DETAIL B Drawn DBB l)aic 4 3 Q 8/6/12 Nevco~ Inc. Greenville, Illinois 62246 Ob.twing No. ShL-ct of 8 9 241-0347 1 D C B A .'1 3 Remove eye bolts from first. row and ;nstall on \=d ,ow Spreader bar preferred for lifting .(see installation instructions for more details) ,..---F I Tighten all bracket bolts on first row before installation second row. STEP ONE frist~II First Row Upper Section Lower Section Column WARNING: · Do not lift scoreboards with any other additional weight attached such as· laterals .or other structural components· Install top row and tighten all bracket bolts. STEP TWO Install Second Row 2 Make power/signal connection between upper and lower n>ws of cabinets after -board has been installed. -connections located behind access doors) -Pull cables from lower section into upper section (connections nmst be made and perminatdy located in upper section) Secure connections to hangers located inside cabinets. Column Bolt installed in top brackets of each row will ~erve as hanger. Hanging Detail 1 Rev b C B DETAIL G Bolt brackets together using bolts, nuts, washers and lock washers supplied by Nevco. (3/8 x l 3/4 bolts) Outdoor Scoreboard Installation 4 11lnEVco 'A Side View Scoreboard Installation 4 DETAIL H 3 2 Column -,Drawn DBB l)atc 2 Nevco, Inc. Greenville, llliDois 6224i> Urawiog No. 241-0347 Sheet ur _8/6/12 9 9 l ~ .., ... _'± .3. ::2', .,;;;, f--------------WIDTH-------------~ c-1-·,..,-" ', , ' (),_ \lffiP,.i ol@rn~$ Addtional display area consisting of signs, ~ arches, message centers or video above or below the scoreboard. (see sheets 4-6) .for colu1:1n and pier sizing)_ _______ _ -------· C B A r SCOREBOARD HEIGHT TOP SCOREBOARD SECTION BOTTOM SCOREBOARD SECTION EIVED L I 'L. EqUWJ ''Att _, (center to center) Equcu FCARLSBAO ING DIVISION Check electrical prints to detennine conduit sizes (must meet code) Steel Column .~ g? SOksi Steel Af se; s11eets 4-6) Concrete must slope away from columns Pier Depth ( see sheets 3-5) ' ~s I •J IJ_ 6" Fro:m end of cohlmn to-edge of concrete 4 !:-Pier Diameter (see sheets 4-6) FRONT VIEW 3 Coarse aggregate concrete {le = 2500 psI minimum) 2 General Notes; 1. Column steel to be grade A992 (50 ksi steel minimum). 2. Laterals and bracing steel to be ASTM ASOO Grade B minimun1 ·(see note l on sheets 4-6). 3. Minimum bolt gr,acle: A307 4. All welds to c011fonn to AWS standards 5. The dimensions in the charts on sheets 4-6 are calculated using the requirements specified in IBC 2009, and the Man-ual of Steel Construction (13th Edition). Soil lateral bearing pressure is -eonsidered to be 150 ,psf/f. 6, The weights of signs to be calc;ulated using 4.3 lb/ sq. ft of sign area. 7. The weights of Nevco message centers to be calculated using 8.5 lb/ sq ft. 8. Tlie weights ofNevco video displays to be calculated U$ii1g 9.5 lbs/sq. ft. 9. The weights of Nevco arches to µe calculated using 7.7 lbs/sq. ft. Important. Read ·before installation. This is not an engineered drawing. It is intended for representational purposes only. The dimensions called out on this drawing are intended to be used as a guide only, and are not intended to be suitable for all conditions. Adding signs or other components around the scoreboard beyond the scope of this drawing qr increasing the display height from the ground will affec.t the installation requirements. Nevco recommends that you consult a professional engineer or architect familiar with the area before attempting installation They can, verify that the selected mounting beams or posts along with th brackets, screws, and other hardware items provi<;led by others or Nevco are adequc;1te for your local soil conditions, wind loads and other local codes. If procedures are used that are not covered in this drawing, careful analysis of the installation is urg~d. B Outdoor Scoreboard Installation 2/3Colum~ Later •1!ijnEVCD 'A Drawn DBB ,Date 2 ,. D Cl B A ~-: _3_ Model 1603,3616,7616 3657 3688 36?0, 7620 1604 110::i\J, ~_::s_l..! 10::i~. I ..... .._---~ ... -...., .. ---~--.;-~~-~ ir/·--·· -·· -· ·-, I / -·-.. -·-.. -· . ' [ Notes: 1) Lateral matedal to be ASTM A500 Grade B minimum. 2) Quantity of laterals in the chart above includes the quantity requir!)(l to mount the scoreboard only and does not include bracing laterals. (See detail on sheet 7 to determit1e required amount of bracing laterals). 4 3) Additional display components ·sucll as signs, message centers or video displays will require additional laterals. See separate instal1ation print for details. 3 2 # Laterals Req. Lateral Length 4 4 4 4 6 -4 31' 6" 25''6" 25'6" 21' 6" 17' 6"' 17' 6" Outdoor Scoreboard Installation 2/3 Column With Laterals Drawn I Date 1/7/13 DBB 2 .. l Rev Bracing Laterals TS 4x 3 x 3/16 TS 4 X 3 x.3/16 TS 4x 3 x 3/16 TS4x 3 x3/16 I ., TS 4x 3 x 3/16 TSAx 3 x3/16 I i ~lnEVCD lfevco, Inc . G!"_envill---"-, _P..lh>,ois _62246 .. Um,tngNo. Sheet of 3 9 241-0360 1 D IC B 'A ~ ._ 4 --.... ____ _L ~ ~ '"7 ~ I l I ...-____,.-... ___...__ v--~ lf9U"l~if PFf1NIND~'ZOThrE1S'I J I Rev I .. r=t: Column and Pier Requirements (Based on ASCE 7-05) :l ..___...,__ ---;=;:, Column and Pier Requirements (Based on ASCE 7-05) ~181 Display Height Pier Dia Pier Depth Col Length Col\imn • ~ ~·j· 'Qisplay Height Pier Dia. Pier Depth Col. Length Column~ raSlb, 8 2· 3' 9'6" 1,·s-1 27'6" 125·5·1 w1"h..!l.? r;. !,:.,. , 8 2' 3• 7,6• r6·i 2s6-124,1 w8 x 21 71 V ~l1. 1 · 11•,q• _ .c.1· ~5, ,.. i'"' , . , , Di\~11·•:J F 12 2' 3' "1:5'110'1 .,. -3:n32'l W12x3cr--.' \0,!·•i '-10 2' 3, 9.'7') 29,127:1 W10x22/ 11D fu bi , •1'41 ,2;-3·1 t14'6""t11'6'1l (38'6"'f35'6~n ,W1'4~' l.!::i:Q· '-1_2 2'_3 ,1?_f_8'1.. 32!,30'1 W10xa6 I CU I ! ..,. 16 2' 3' 16' (12'"'-'-42' 138'6"1 W16 36 I 1 ~ , :. '1>!< l2' 3'. l -~-1.6 '19 :Ii t35'6 "13311 1WV,2¥,26' "d' ~j -.:_.. • 3'6"} 0 X ~ [CU 11i 2' 3' 12'6"110'1 38'6"136"1 W1Lx30 '.~ .. ;:I{ 20 F X ~·----.,;.114'16_"1 _-~-; v ..__ ,_-45 ;.,. I~' 18'\. 2' 3: 14: (11: 42: 39'1 rn-4 X34 :11)1 22 ,.._ -2' 3' 20'6"116'1 52'6"148'1 W1Rx50 ::f: _1:1>\ 20 " 2' 3 15 112 45 42'1 -16 x36 l:. O.i 25 / 3' 4' 18'6" (15'6"1 53'6" 150'6"1 W21 X 55 ~ OJ 22 '\. Z' 6 1ot>, l Ii<, } 'Rj,t> """'} / Wl 6 X 40 \ ~. ~ 30, 3' 4' 21'6"(18') 61'6"(581 . W24x68 fr, ~ 25 ... 3' 4 14t,· (U I 49'6" 476'1 / W16x50 ~till ~ 3' 4' 24'6'120'6"1 69'6":(65'6"1 W24x84 t'.:! ~j 30 ' ;;· . ' c,~. ·::,r ~0 ~ W21 x55 i',...__ l::,::, ~ 40 3' 4' 27'6" 123'1 77'6" f731 W24 x94 -' 35 '-;:s· .::u ( lt>t ti':J' il'ti") / W21 ·X 68 I~ . -40 3· ««t>(18'f> '""' t><>o·y W24x76 0 t,..__/ Column and Pier Requirements {Based on ASCE 7-05) ::.-\,;OIU1m1 an 1er eautrements ctsas= on A ;ci,, 1-u!"> 1-~ c.> Display Height Pier Dia Pier Depth Col. l,.ength Column• ~ 8 Display Height Pier"!; ia. Pier Depth Col. Length I Column • l1S N a 2' 3 11'19'6"1 29'127'6"1 W10x26 l1S 8 z 'if6"(8'6"1 27'6' z1>6")/ W10x22 1n 10 2'3' ·12'6"110'6"1 32'6"130'6"1 W12x30 +iN 10 .!. '\. 10'6"n:n ;w6"1.<l:f'V W10x26 S:: ' ·. 12 2' 3' 14' (11'6" 36'(33'6"1 W14 x 34 ~ ' 12 z , 1 l'b" ciu-1 ;:s;:s'b" =l W12x 26 -0 14 2' 3' 15'6"(12' 39'6"(36'1 W16x36 -i:Q 14 Z i'-1.::o (IUOJ 600 11'4'lj") W12x30 Cl1 Q) 16 2' 3 17'6"C13'6"\ 43'G" 139'6"1 W1Sx40 ci, ci, 16 z" '-14' 111'6") 40'., o"I \All4x34 '0 ;.. 18 2' 3 19'6"'115'1 47'6~t43'1 W14x48 '0 1,c 1R 2' 3' '15'6"(12'1 a:-vn• 40'1 W16x~6 :::: ::S 20 2' 3 21'(16'1 51'146') W18x50 ... ::S 20 2''3' 1'&'6"113'1 Ab'6" 43'1 W16X40 Cj.? ~ . 22 2' 3 22'6" 117'6") 54'6" 149'6'1 W1" x 55 === f/l 22 2' 3' 1111. 14'1 f 50' 146'1 W21 X 44 -s::i. 25 3' 4' 19'6" 116'1 54'6'' 151'1 W21 x 62 -O 25 3' 4' 15'6 11.13'-1 F 50'6" [48'1 W18x 50 ~ ~ 30 3'· 4 23'6" 119'6"1 63'6" 159'6"1 W24x 76 ~ ~ 30 3' 4' 19' 1~1 59' (56'1 W21 x 62 f;i;l 35 3' 4' 27'C22'6"l 72'167'6"1' W24x94 r.:i:l 35 .3'·4' 22' 18'l>. / 67'1631 .W24x68 -40 3' 4 30'6~ 125'6'1 80'6" (75'6"1 W24 x 104 -40 3' 4' 24'6" 20'6Y 74'6" 170'6'1 W24 x 84 a \jO umn ana t-'1er t eauIrements ctsasea on A~ ;i--,-::.-Column and Pier Reauireme't\ts <Based on As E 7-051 ~ 8 lJ1So1av He1ant Pier Dia. t'1er ueotn vol. Len tn. Column• ~ R LJ1sP1av Heiant Pier Dia. ~er LJecm vol. Lern:im cis · 8 , 2' 3 10' 18'6" .28' 126'6" , W10 x 22 -._,, 8 2' 3' f 8'6" C7'6"1 '\. 26'6" 125'6"\ +i('I) 10 2'3 11'(9'6" 31'129'6" W10x26 ~('I) 10 2'3'. / 9'6"-8'. X 29'6'(28" ~ • 12 2' 3 11'6" (10' 33'6" 32' W12 x 26 Cll , 12· 2· ;:s· 1u 1,,0· '-;,.c· 1.>uo ~-0 14 2' ~-1z-t•"C11 .>ot> W12x30 S:: p:i 14 2' ' / 11'1:j·b--'\. ;;::033'6": 16 • ~· 14'(11o ""'I~ W14x34 ..,. 16 .:· f ll'b'' 1t·'J '-;,1'1:;,,.,a ,8 f, 18 ~· foo 12· 4,n,· 4 W16x36 ,8 f 18 <!' : / 1.::o. 1uo 1 -..i.u·t;· 1.>00') .... ::s 20 2· ;, 17' (13'1 4 "' W16x40 • .,. ;:s 20 2' I/ , 160 111·1 ...,., (41') ·=== 0 ?? ~-4 14 11.:·1 4 t44' W21 x44 · ·=== 111 22 .,. 11b" luo 4:..-...:·(4.:·0·1 _ 0 25 j'4 1:>0_1;:s· '""' 4 W18xfi0 _ 0 25 ., 1.::o 110-4,o,4001 N Ile 30 3',. 18'(1 ,o :.ll ,: ,t W21 x62 N c:lt 30. Z 4' 14·0 1.:·t> ""o 1=0 > ('I),~ 35 3'4 21'6."11ts bl)t,:n;;· W24X68 ('I)~ 35 ,., . ., 110[1':J' o,:;omv') 0,. 40 ;:s·,. .!4'ti"""O ,,.o ,u W24xR4 f:'!_ 40 f 3' 4' 20't16'6"1 70'166'6'\. Column• W8x18 W8x21 W10 X22 W10 x26 W12 x26 W12X30 W14 x34 W18x35 W16.x40 W16x 50 W21 x55 .W21 x68 _ Column and Pier 1 :P.C1uirements:R::ised on ASC-7-051 \jOJUmn ana t-'1er r eou1rements.(tsasea·on A::iP--~05· Bl ,A 0 u1sP1av He1am · Pier Dia l-"1er ueot \jOI. Len 1 :1 Column• ;:::;0 . uIsP1a, HeIant Pier Dia. l-"1er ueotn uO!. Lenatn '\ r.n1umn• ~ 9 2· 3' 11 i::nn 30 czo W1 Ox 26 ~ 2' 3' / 9'6" 18' 9'6" 18'1 28'6" 127' \. W8 x 21 cis O 10 2' 3' 11'6"(10' 31'6"130' W12x2n al c.> 2' 3' / 10' 8'6 10' 8'6" 30' 28'6" '\. W10x22 ~ (') 11 · 2' 3' 12'110'6" 33'131'6" W12x26 t; ('I) 2· •/ lu1 (l:f 1u, c::, ;:s1, c;-su '\.W14x22 .s::' 12 2·;:s· 1.::o(lvc·i :;s4·0 1,v.c1 W12x!'!O s::' 2· 11,::,o 11 ::10 -"1-'•o W10x26 -0 13 2· ;:s 13'o· 111 .mo <:c!4' W14x!'!O -i:1:1 2' ~· 11' 9'6" 11' 9'6" 34' 32'6" W'\2x26 ~ ~ 14 2' 3' 14'(11'6" <1H'(35'6" W14x34 ,8 Q1 q 11'6 (lU'l 11'6 Ill ;,:n (34' W1?.:,c26 ... ~ 15 2·;:s 15'12') 40'\-'rJ W18x35 ... l:; .e· 1..:·11uo·, 1..:·11uo ;:s,c~:,o W12~!'!0, ---l=== 0 20 3' 4' 14't>"(l;o:·o·, ,44'6 14Z'O'I W14x48 === 111 /3'' 4' 12'110'6"\ 12'110'6" 42' 40'6" W16x~ "' 8_ 25 3' 4' 17'6"!14'6"> 52'6"149'6") W21 X'-'--o / 3' 4' 14' 12') 14' 12' 49' 47'} W21 x44, ~ ~ 30 3' 4' 20'6" 17') 60'6" 57") W21 x 68 ~ ~ / ;:s· 4· 10·0--'.14'} lt:ftf' ll4') :>t>t) (:)4') W18 x 55 f;i;l 35 ;;s-4· z-1r1::,01 txj'(64'.6'·1 W24x76 r.:i:l ;:s·q. nrc-10·1 nri1tn 64'161'\ W21x62 -40 ;:s· 4· .::, o ,,_, 1 , , o I I·' > W24 x 94 , 3' 4' 22' 18'6"1 22' (18'6") 72' 168'6"1 W24 x 76 'Chart Notes: 1. "It is required that 4x3x3/ 16 steel tubing be welded · o back of columns 10' from the ground and -every 1 O' to the top of the column for bracing. (See detml on sheet 7) 2. Wind loading f.gured at@xposure'"Cw-:.7O:j>en-tet-tfilp;with scattered obstructions having heights Al genera1ly less th:m 30 feet. This category includes flat open country, grasslands, iind.all water surfaces in hurricane prone areas. 3. Wind loading figured at~sure-''B'-'~-"Vrbati:'.andrsuliui:b;lg(:a;ea~\ wooded ai·eas, or other terrain with numerous closely spaced obstructions having the size of single-family dwellings or larger. These -areas prevail in the upwind direction for a distance of 2600 feet or 20 times the structure height, whichever is greater. 4 I 3 ~ Drawn 2 Outdoor Scoreb.oard Installation 2/3 Column With Laterals DBB Dale l./7/13 I .«lilnEVCD Nevco_, Inc .. ' Green,iille, llllnois 62246 l)rawing Nb. Sh~'!-lt or 4 9 241-0360 1 C f<l-- B t- 'A D - C -e, 4 I _3_ "'7 2 I l Additional com1Jonents from additional column length when installation consists of additional F (f Dimensions must be increased by an amount equal to the .c,,\, I Rev I I 1)'~ IMPORTANT: Nevco may be installed on display com.ponents above the scoreboard. If additional column •r~nt laterals also. See separate length is used to extend above the display, add the additional 0 r-ir-_ ~ / Weld short side of }... II I ll--J::::,!~I laterals to column face. (includes bracing j11.stallatioll..J?.ti.11.t. ___ 11_ length to the top dimension below. Dimensions should be Top ofscote<fl&!P& I I I ( measured from the top of the shortest column. (shown flush with I Ad~itional I I \ top of column) !\'fti,-C laterals) I display I I \. 2 ¼'' (All Models) ~ ~ I---compon~~--I -~~_J _______________ .....,. ______ ' ____ _ ___ 7 I lfs:J I ~lA I Dimension is lo Dimension is to I I bottom of ne:i-.1: top of next lateral I I lateral. .. .. ! I Scoreboard I I "C" Laterals Upper Section I I . I Column\ 1-----~----------------------4 I . . I I 0 . . . I mtens10n 1s to-------I I LateJ·als bottom of next ----... " . " '' , •· "F" I I lateral. I Scoreboard I I I ower Section 1 I ~=:~==~~::::::::::::::::~-----+--t-LateralWidth L _____ -t)'q,,al :----------~~a:.-'"-:w --j -----_--+Equru~-----J .. " .1!.... .. ....... = .... .... . . .. ...... . ... == ..... .. ======= I [Note: Bottom section shown for boards with three (3) rows I Lateral and Hardware Requirements for 3 row Boards(hardware supplied by others) .--If 10' or less, no brace is 1:equired at top of column ,_,_ TS 4.x3x3/ 16 /I f 10' Max l J l Collun,:1.-------.._ 101 REAR VIEW Ma.--.. 1 LGround Leve[ Bracing: Laterals must he weldecl to back of columns 10' apart from the ground tip as shown for bracing. 10' spacing must be maintained. Laterals must extend to outer edge of both columns. D I- C ~ Bl Model Number I Dim "B" I C I D I E I F I Lateral Width I 3/8 Washers I 3/8 Lock I 3/8 Nuts B A · 7605,7615, 7625 257/8 1301/1617315/161783/161122 17'6" 72 36 36 Lateral and Hardware Requirements for 2 row Boards{harclware supplied by others) Model# I Dim "B" I Dim "C" I Dim "D" I Lateral Width I 3/8 Washers I 3/8 Lock Washers 3/8 Nuts 3616,7616 553/4" 601/8" 115 7/8" 31'6" 481/8" 103 7/8" 60 1/8" 11 7 8" 481/8" 91 7/8" 481/8" 91 7/8" '~ 3618, 3619, I ~.:sJ£ 1 tt1S:-1=18,:; 1 (9r118.: I (t:il··ir, 3685, 7630, 7631,7632,7685 Hardware Notes: 64 48 I :!.&) .= 32 32 3-2. 32 24 ~ 32 .3.2 32 32 24 @j Required Hanel Tools: 1. Drill with phillips driver. General Notes: 1) See sheet 3 for lateral size requirements. 2) Center and weld Laterals to front fac;:e of coh.unns (weld around full perimeter of contact surface with 3 / 16 fillet. 3) Dimensions above should be taken from the top of the SHORTE$T column, marked and leveled across to other column. 4) Mounting Brackets shipped in -separate container. Outdoor Scoreboard Installation 2/3 Column With Laterals ... 1ifnEVCD Nevco. Inc. Greenville, Illinois 62246 I- 'A 1) Minimum 1JOlt grade: A307. 2) Hardware above is not required if wek1ing brackets to laterals. 3) Consider lateral size when choosing bolt length. _Q, 9/16" wrench Drawing.No. 241-0360 3. Ratchet wrench and 9 / 16" s,~c~.1~,e::.!t:...._ ___ ..-::::--:---------Jf-;;;:-::-:---:::;:-----------7 4. Level . f)rawn DBB Date 1/7/13 ·• Sheet of 5_,_T_i!J)_e mea~mre 7 9 4 I 3 4\ 2 I 1 D C B A ""- 3/8 x 1 1/4 bolts, nuts and washers (supplied by Nevco) WARNING: Stack up to 3 washers under eye bolt if longer than 1''. Do not leave any screw locations emJlty. 3_ 2_ Threads: 3/8" -16'\@ ~imum. Slide bottom bracket up and tighten one l>olt to hold in place DETAIL E Replace access doors when finished making connection$ Install 3/8-16 eye bolts into top of board (lower row of cabinets 1st) for lifting. (eye bolts and washers supplied by others) Top brackets are fL--c:ed position. [] l 3/8 x 1 1/4 bolts, nuts I Rev j I and washers (supplied '---'----1 by Ncvco} DETAIL C Screw sections together front and back using screws supplied by Nevco Make signal connections between board sections before installing scoreboard- (connections located behind access doors with "SPLICE 4 ENCLOSURE" label) Secure connections to hangers located inside cabinets. lJ.. I -,-Inse;t e,-ten,ded flange into matmg section (make sure both flanges of male end go to~ offemale end) DETAIL B Important: Screw· sections together pdor to installing board onto columns. (Upper row 0£ cabinets and 1·ower row of cabinets do not connect) 3 CABLE HANGER Notes: 1) Signal connections from lower row of cabinets to upper row should be made after both rows have been installed on columns. (see sheet 8 fo1' details) 2) Make sure all bracl,<et bolts are tight before .installating scoreboard. Outdoor Scoreboard Installation .afilnEVCD 2/3 Column With Laterals Urawn DBB Dc-ttc 1/7/13 2 Nevc::o,lnc. Green'l7ille, Illinois 62246 Ut·awing No. 241-0360 ShL-.!l ()I' 8 9 1 D C B 'A D C B A 4 Remove eye bolts from first row and install on second row Step1 Spreader bar pr(iferrecl for lifting (see installation instructions for more details) .a Install. Bottom Row Step2 Install Top Row F ', _,,; 4 Column IF Ii\. '.\ Column Upper Section Colunmll, \'/ J DETAIL G 1-------;---><-Weld (3 / 16 fillet) or Bolt brackets to DErAIL H 3 laterals using 3 /8 bolts, nuts, washers and lock washers supplied by others. (bolt length to• be determined by installerc; .See lateral si',!e required on sheets 3-5) 2_ Make power/signal connectiot'ls between upper and lower rows of cabinets after boanl has been installed. -connections located behind access doors labeled "splice enclosure" -Pull cables from lower section into upper section (connectio_ns must be made and perminately located in~ section) 1 Rev CABLE HANGER Upper Section Lower Section (2) 3 /8 bolts required to bolt bracket to lateral. DETAIL I WARNING: Do not lift scoreboards with any additional weight attached such as lateral!:_; or other structural components Outdoor Scoreboard Installation 2/3 Column With Lateral:; ·~nEVCD Nevco, 111.c. Greenville, Illinois 6224«1 Urawing No, 241-0360 lJrawn DBB Dale 1/7/13 Shc~I <11" 9 9 2 1 D C B 'A \ 'r ·,: .. " . 8FT FOOTBALL GOALPOST FBGP-930 8' Offset Football Goal Posts > Semi-permanent install 6-5/8" main upright with adjustable uprights and· crossbar for exact installations. > High school and College sizes available. FBGP~ '\::iO High School Yellow ·----23'-4" I 18'-6"------11"1~1 7411 • RECEIVE I I I I I I 36" Optional Safety Padding • Recommended Footing Size APR 15 2013 CITY OF CARLSBAD BUILDING DIVISION MODEL: FBGP0~ '3 0 MAX-1 FOOTBALL GOALPOST T·\tl11<.u111enl.l\Mem~r1.e\1f,;ctbJl~fB•JP·TlO\Dm,tn91\fllGP·S)O $PEC.ld1v CCPrfl!CHr 20,)3 .l~Yfl'!O &'C'RTS. LLC, P!LPJOffSf5ro<'.'EO I I I I I I 40' 8'~ ~-~ Sc.,(.. H-h-~t. \L~ ·\- t Pt <..c...c... ":, > Fr {,.w,·e. · 1 GOOSENECI<, 6-5/8" SQ-l 40 2 END PIECE 3 CROSS-BAR, 6-5/8" SCH 40 4 UPRIGHTS, 4" O.D. x 30 FT II . description ALUMINUM ALUMINUM ALUMINUM ALUMINUM material ~- MAX-1 FOOTBALL HINGE KIT MODEL FBHG-1 TURF GROUND LEVfL 12in 18 in 64in [..__ 361n ~- .(FOOTING) FIGURE 4 See Figure 1 for footing plate orientation. RECOMMEND 5/8 In x 54 II) REBAR (QTY 6) (BY OTHERS)' Note: Lubricate hinge pins with a light grease such as White Lithium Grease to prevent rusting and help when installing or removing the hinge pins. 7. INSTALLATION STEPS Follow these steps to install the foundation at each end of the playing field. 1. Excavate the footing hole; as shown in Figure 3. 2. While not required, Jaypro recommends using 6 lengths of 5/8-inch rebar, 54 inches long, wired together into a 24-inch diameter basket and placed around the ground sleeve in the footer hole. 3. Assemble and install the anchor kit as shown. NOTE: Use the 12" x 17 ½ " footing plate supplied with the Hinge Kit and note the orientation of the plate. The longer 17 ½ " side is parallel to the field. 4. Fill the footing hole with 4,000 psi (minimum) concrete to 12 inches below ground level. MARCH 4, 2011 a, Page 9 -~ -....-: ~ 'I -, B ,\I 74in A 1 5/8~, t 8in s 66in -, 12 in l ½ 2 I ~ 100 3/8" (8ft EXTENSION) OR 82 3/8" ~• OF END LINE (FIELD SIDE) TO (~:~~NSION) FROM INSIDE EDGE e,/' OF GROUND SLEEVE. I ""- GOOSE NECK ------(FBGP-800US) 8 ft EXT ~ GROUND LEVEL 5/8" -11 THREADED ANTI-ROTATION ROD 10.75" LONG -, 1 , WITH 5/8'' HEX NUTS AND WASHERS. !!_;j • &* DRILL 011/16 HOLES IN GOOSENECK WHEN PLUMBED AND ALIGNED WITH PLAYING FIELD. 3X 1/2"-13x 2" LONG HEX BOLTS WITH 1/2" JAM NUTS TO CENTER AND PLUMB GOOSENECK. NOTE: CONTRACTOR/ INSTALLER SHALL CONSULT RECEIVED APR 1.5 2013 CITY OF CARLSBAD BUILDING DIVISION CODES AND SOIL CONDITION FOR FINAL FOUNDATION DEPTH AND SIZE. 5/8'' -11 THREADED CENTERING ROD 8.875" LONG WITH 5/8" JAM NUTS. m z 0 r z m REV DESCRIPTION !NIT. DATE PACKED GRAVEL OR CONCRETE PAD POURED CONCRETE M:iORAY.1Ntol:ii'1E~-PRQl'UlTYOFJA'tP'Ro~r.:,SNC,~IMVNOf1tt.,Efliloai.ictW \\.fl'wet.ll~l:t'_CJ.11$.~0C,_CO'JSn(r" PROJECTION METHOD: I TOLEP.,0.1\CES· @ cJ 0. = .1·3 0.0 = .06 0.00 = ,03 UNLESS OTHERWISE SPECIFIED TITLE: I . INITIALS: I DATE: . DESIGNER: I MT I 8/212007 CHECKER: W/8 9/19/2007 A . FBGP-804 Rev. A MJE 8/1/2008 B FBGP-804 REV B, ACCOUNT FOR X-DEFL. OF GN MJE 9/8/2009 C Revised Footing added 6 ft Extension Info ORL 2/23/2011IA D PART NO WAS SLEEVE INSTALL ASSEMBLY DRL ~/20/2011 PHONE: 800.243.0533·(TOLL FREE) 860-447.3001 (LOCAL) ,:;~~,c _, PART NUMBER: I I SIZE: I SCALE· I REV.: !DRAWING NAME: . '\> , . . 36 , . . A. NIA D FBGP-~AX-1 GROUND SLEEVE T:\Aftermarket\Football\FBGP-800\FBGP-~OO -Production\FBGP-MAX-1. GRSLEEVE.h;!ffi. FBGP-MAX-1 GRSLEEVE 1 SHEET: 11 OF 1 ' '!1.: .. 2.3 Football Goal Post Backstop Netting System: A. Football Goal Post Backstop Netting System 1. Type: Football Safety Netting System as manufactured by: Jaypro Sports, LLC, 976 Hartford Tpk, Watford, CT 06385 is the standard of quality required and specified herein. Local Representative is California Facility Specialties at 909· 599-1200. 2. Components; a. Uprights: 1) Upright Posts Fabricated of 6in Schedule 40 Aluminum: Length: 45.0ft, 40.0ft above Ground 2) Powder Coated Finish 3) Ground Sleeves: a) Ground Sl~eJes Fabricated of 7 .Oin OD b} (.109in wall} Steel Pipe c) Length: 60.0in d) Aluminum Ground Sleeve Caps b., Football Safety Net: 1) Safety Net, 40.0ft H x 40.0ft L a) 4.Qin Knotless Nylon, Bounded on all Edges 2} Accessories: a) Hardware Kit b} Stainless Steel Assembly Bolts c) Wire Rope • ~ Elevator Submittal Package Date _Subm'.itted: _February 12 2013 For Project ARM.Y-NAVY ACADEMY ATHLETIC FACILITY TK'E Job Number: 303-246-01A Elevator(s): 1 Located at Preliminary I · 2605 CARLSBAD BLVD. ' ' Drawings . · .. · CARLSBAD, f?A 92008 For Approval --1 •• · Company (Mail to) ~iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii~ TURNER CONSTRUCTION COMPANY 9330.SCRANTO-N ROAD, SUITE 300, SAN DIEGO, CALIFORNIA 92121 Architects Submittal Review D Approved IXJ Approved as noted D Revise and resubmit This review Is only for general conformance with the design concept of the project and general compliance with information given in the Contract Documents. Corrections or comments made in this submittal review do not relieve the contractor from compliance with the requirements of the plans and specifications. Approval of a specific Item shall not include approval of an assembly of which the item Is a component. The Contractor Is responsible for dimensions to be confirmed and correlated at the job site, information that penains solely to the fabrication processes or to the means, methods, techniques, sequences and procedures of construction, coordination of work wlth that of all other trades and for performing all work in a safe and satisfactory manner. House and Dodge Design, Inc, Date: 03/18/2013 av, Kevin Hallock ThyssenKrupp Elevator Americas GC Phone: 858-320-4040 Attention: DAN DEKOEYER RECEIVED APR 1 5 2013 CITY OF CARLSBAD BUILDING DIVISION {f) TURNER CONSTRUCTION COMPANY Reviewed for General Acceptance only. This review does not relieve the Subcontractor of the responsibility for making the work conform to the requirements of the contract. The Subcontractor is responsible for all dimensions, correct fabrication and accurate fit with the work of other trades, SUBJECT TO ARCHITECTS APPROVAL BY: C. Rodriguez SPEC NO·-PARAGRAPH DIV 142400 Part 1.4 A,B DATE: 0J/08/2013 Submittal# 0001-142400-0 "S ' Date Submitted: February 12 2013 , lnformatio-n a-nd I nst.r·uctions Job Information: Company: Phone: Fax: Attn: Elevator: 1 Turner Construction Company 9330 Scranton Road , Suite 300 San Diego; California 92121 858-320-4040 858-558-4408 Dan deKoeyer Package lnfo.rmation: 1:KI;:· Local Contacts Description -Information and-Instructions · Apprqval Selectiop Sheet Main Eleva-for Layqut Entrance Detail 'Drawing Remarks: Type .. lnfqrniation -No 'qctiori Required . Fqr Approval -Signature Required. _ ·For Approval -Signature R,eqqired= For Approvai -Signature Reql!ired • The enclosed submittals are in compliance with conditions of ThyssenKrupp -Elevator's subcontract for sµpplyin9, and installing material and/or systems for the project referenced above. • This elevator installation is an integral design. Due to this nature, no equipment can be released to fabrication without all appropriate approvals and confirmations. • "Approvals" must contain inclusive confirmation as stated in the section titled "Remittance Instructions". • Failure to provide and approve this information in a timely manner may result in a delay of elevator fabrication and delivery to job site. TURNER CONSTRUCTION COMPANY Reviewed for General Acceptance only. This review does not relieve the Subcontractor of the responsibility for making the work conform to the requirements of the contract The Subcontractor is responsible for all dimensions, correct fabrication and accurate fit with the work of other trades. SUBJECT TO ARCHITECTS APPROVAL BY: Q BQd[i9U§l: SPEC NO -PARAGRAPH DIV 142400 Part 1.4 A,B DATE: Q3iQ/l/2QlJ Submittal# 0001-142400-0 (For Information Only) . Co.ntact Information: TKE Local Contacts Sales Representative -John Swilley , 619-596-7220 · Construction Superintendent -David Schaf~r 619-596-7220 Project Manager -John Swiiley 619-596.a 7220 Remittance-Instructions: Please Remit at least ~ copies of all confirmations and approvals to: Office Location: ThyssenKrupp Elevator -SAN DIEGO Attn: John Swilley 19E;i5 Gillespie Wqy, Suite 1.01 El Cajon, CA 92020 Phone: 619-596-7220 Fax: 8E;i6-572-15q7 · ThyssenKrupp will not relea:se any elevator· material for fabrication without the following information, in addition to a fully executed subcontract agreement. O Plea~e review the elevator layouts ancj detail drawings closely. Check ALL:hoistwc,3y dimensions, elevator travel (floor to floor heights), pit depth, clear over-head, machine room dimensions, and entrance wall thicknesses. Mark-up the drawings accordingly, and remit with necessary approval (i.e., approved or approved as noted) to the Local ThyssenKrupp Elevator Office shown above. D Enclosed drawings are for approval purposes only and not to be used for construction. El Please confirm finishes and indicate your color selections on the Approval Selection Sheet in this package. D Please confirm entrance wall thickness and type on the Approval Selection Sheet in this package. D Please confirm the Main landing for Firefighters' Recall service (Phase-1 Recall) on Approval Selection Sheet in this package. D Please confirm or correct the building power shown in the "Power.Confirmation" section on the Approval Selection Sheet in this package. D Completed and signed Material Release F~rm. This form is provided by the Local ThyssenKrupp Elevator Representative. Any/ALL previously quoted manufacturing lead-times for material delivery, shall begin the date-of receipt by ThyssenKrupp of ALL approvals, confirmations, and a fully executed subcontract agreement. The installation start date cannot be any earlier than the delivery of the material to the site and the completion of all items shown on the Pre-Installation Checklist sent to you in this submittal package. ~ ~, ,u · Date Submitted: February· 12 2013 · Approval Selection Sheet JURNER CON.STRUCTION ·cqMPANY Revie'Ned tOr <3eneral Acceptance only. This review does not r~l1eve the Subcon!ractor of the responsibllrty for n:iaking the work confofm ,to the-requ1iements of t.~e contrapt The1~ Subcontractor 1s responsible for all dilllens1ons, coriect 'tabrfcation and accurate frt 'Mth the wcirk of other trades. SUBJECT TO AR\:HITEPS APPROVAL · . · (Approval Required)· . . · BY: ~ SPEC.NO-PARAGRAPH DIV 142400 Part 1.4 A,B ARMY-.NAVY ACADEMY AT,HLETIC FACILITY/303-246-01A ca·b Fin·ish Selecti·on: Elevator(s): 1 Please select elevator colors and finishes for the items listed below. Be $Ure to inclade your signature below and fill out all items. Cab Wall: {TKAP) 16ga. -Please select Plastic Laminate color Formica: Pecan Woodline, Matte Finish - Reveals: . Powc;ler Coated Color: Black F-112 5883-58 Cab Ceiling: DOWN LIGHT(LED)-METAL Finish: #4 Series 300 Stainless Cab Doors: STAINLESS STEEL, WI #4 BRUSH FINISH Cab Sill(s): Aluminum Cab-Flooring: By others -provide weight if other than car.pet or vet_ Terrazz? tile is ~/4"Thk'(6.6mm) an . (Maximllm 3/8" thickness) 2.871bs,sq.ft Cab Handrails: (1) Bar·1)l4" x 2" #-4 Stainles~ Steel 1 Bar 1.5"Cylindrical with Return Ends, Brushed Stainless finish Cab Protection: None Approval: Kevin Hallock .Power Confirmation·: Elevator(s): 1 Controller: Starting Type: 460 Volts A.C.,3 Phase 60 Cycles Solid State Starting Lighting Supply: 120 Volts, 15 Amps Date: 03/20/2013 Based on this information, we require electrical feeders and fused disconnects sized per the following information: Power Feeders Total Rated Short Circuit Elevator Motor Starting A.C. (Full Load) A.C.Amps Current Rating Designation Horse Power Amps A.C. Amps (At 600v Or Less) 1 25 102 50 34 5,000 Amps We request that this information be confirmed by the electrical contractor. Please check the box below that applies. If the power supply is different than shown above, please be sure to fill in the correct voltage. Iii Confirmed Power shown above. D Corrected Power Supply (AC) ____ Volts: ___ Phase ___ Cycles; 3 Wire + Ground Is operation on emergency power source (by others) required? YES or NO (please circle one). If yes, how many elevators will be capable of running at the same time while on emergency power? ____ _ Approval: Date: DATE: 03/08/2.013 ·· Submittal# 0D01-1.42400-:(J, Entrance Confirmation and Finish Selections: . ,_. -·-----'--~· ·~·· --~ ' Elevator(s): 1 · Please complete the blank cells in the tabl~ below. ThyssenKrupp E;levator needs this information. to properly design the entrance frames for your building. The floor markings shown in the left hand column are f9r approval and are to be ·corrected accordingly in the adjacent column. When providing the wall type c!nd thickness, pl~ase referenc;e the detail below for assistance. Please review and approve the entrance frame, door, and sill finish shown below. if baked enamel frame or . doot shown, write in the desired color from the TKE standard baked enamel collectJon chart. Floor I Corrected Provide Wall Provide Wall 'Entrance. Frame . Entrance Door Entrance Lanaing Floor Type Thickness Markings Markings (See Detail Below)· rx· detailed. below) Finish. F.inish Sill 2 I Drywall 6 3/4" #4 STLS #4.STLS Aluminum 1 1· I Drywall 6 3/4" :#4 STLS 1#4 STl,.S I Aluminum Provide Firefighters' Recall Floor: I (Main): 1 (Alt): (Main floor is the building egress level; alternate is typically the next floor above.) Entrance Wall Detail me l_~ Elevator Entrance Frame "X" T DRYWALL TYPE FRAME Approval: Kevin Hallock Date: 03/20/2013 ct :I llj~I.AA. 11 I 2rBMcmoA · I HOISW~I· ..L ' INSERT ~'J .. t [ :1·~r:-:-~::-~_~;;:.,: l~i ·,.~r :. -::. ·-.:=:~--:~ ··.;:.:, ~?e,-~0-INSE~i STITCH-WELD TO STE::t (INSERT) PROVIDED TKE, INSTALLED CONC. ANCHOR BY G,C, MOUNT FLUSH WITH wALL AT PIT LEVEL ALL FLOORS ABOVE PIT AND IN OVERHEAD TYPICAL BRACKET MOUNTING SAFETY BEAM REC'D. PER OSHA 1926.502 PROVIDED & INSTALLED BY OTHERS, AS DIRECTED BYTHYSSENKRUPP FIELD OFFl~E DESIGN LOAD= 5000 LBS.{STATIC, NOT IMPACT) i..l .,_ ;.·.731,4·.;...TI· I½-- w 1!' ~ WW ~ • ~5s ~ ~ n , .. I'+--+~· flNISHED FLOOR ~ ~ 0 :i :i! ~ "' · 1' '?:,: ic ~ ~ z :i! -1:U;--=---' - "' ;:;. z ~'* !. .,_ 4ll I I I fnl~ I en~ I ,,§ i I I I I I q I 1. 'I FLOOR-FLOOR I TRAVEL I 1·2 , __ I_ 12"-6" it ~· 'W ,, ~ ii'. "- NET TRAVEL TOPO.T. BOTTOMO.T. TOTAL TRAVEL I PRIMARY FIRE SERVICE LOCATED AT FLR: 1 W/ALTATFLR. FINISHED FLOOR 1 .E:£.. + s· + , 10· 13·.10· NOTE: IF DISTANCE BETWEEN FLOOR LEVELS EXCEEDS MAXIMUM, AN ADDITIONAL GUIDE I ~ RAIL BRACKET MUST BE ----·~ = m ~ ~ R ~ il2> i'.5 ~ :i :i! "' ;;; ·1~ ~~ ~ I I I I '1- !c ;; ,1~ - ,-. "' ~ ~ ·,i tf '"1+L MAXIMUM UNSUPPORTED RAIL BRACKET SPACING= 15·-s· "T+r- .. ~ufc'.3 r.i1~~:i ., 1-1=-~ ~~~­~-~~~ ~E!t;t lL:i<:c 0 ~ E !:2 / FIN. FLR. -·~~::~ :~ (FIRE) (FRONT) STOP SCHEME MOUNT RAIL BRACKETS AT 1'-4~ BELOW EACH FINISHED FLOOR LEVEL ~~ -1~ ~~ ,__ V -u l L JW a.> CYLINDER LENGTH= 14'~11/4• PLUNGER LENGTH = 14'.a 314• SECTION VIEW A-A NOTTO SCALE ~ <Ii ~ ~ " 0: L CUSTOMERAPPROVALBOX HYDRAULIC ELEVATOR CONTRACT DATA (TIIESE ITEMS MUST BE VERIAED BEFORETH_E_laLEVATOR Yl!LL BE_ MANUFACTUREDl , _ ------TYPE: . endura ELEV# 1 NET TRAVEC: I J;fCONFIRMED AS SHOWN ON SECTION VIEW SPEED: 102 FPM UP_ , 127'FPM DOWN MAX. CAPACITY: 3500· ~ r- t LIGHT, SWITCH AND CONV. OUTLET BY GEN. <;:ONTR. r-- 1 ,-: .i : 7 I I ;; ~ I i [i . "'w ..,.10 ~ L~2; I · I I."' ' 1~8 L--_ _j i'°c a·..s·· . MIN, CLEARANCE ' TELEPHONE ~ , -.JJJ!i<,I[OJ!!.. -""" \ 0CORRECTED: CLEAR OVERHEAD: l!J CONFIRMED AS SHOWN ON SECTION VIEW J;I_CORRECTED: PIT DEPTH: l!JCONFIRMED AS SHOWN ON SECTION VIEW 0 CORRECTED: IHANl:J'OF DOORS: IJ CO.NFIRMED AS SHOWN ON P1'AN VIEW JJCORRECTED: HOISTWAY SIZE:· II CONFIRMED AS SHOWN ON PLAN VIEW 0 CORRECTED: !MACHINE ROOM SIZE: I II CONFIRMED AS Sl;lOWN ON PLAN VIEW see, note DCORRECTED: APPROVAL: Kevin Hallock A MEANS TO AUTOMATICAL~Y DISCONNECT THE 'MAIN LINE POWER SUPPLY TO THE ELEVATOR PRIOR TO THE APPLICATION OF WATER IN THE ELEV. MACHINE ROOM OR HOIS1WAY 'Nill BE FURNISHED BY THE ELECTRICAL CONTRACTOR. THIS MEANS SHALL NOT BE SELF RESETTING. Z' OIL LINE FROM TANK TO 2"" SHUTOFF VALVE. 2" SCH 40 BU( PIPE, ASTM A·53; TYPE E ORS, GRADE 8 OR EQUIVALENT TO JACK. DATE:-03/20/2013 ~p_L 6'-6" , . I\__ MANUP. TO CONFIRM LOCATION AND HEATLOADINMACHINEROOMDUETOELEV.EQUIPMENT=13784BTUIHR ORRIENTATION WITH ARCHITECTURAL PLANS. MACHINE RQOM PLAN LOCATION: 20 Feel Remote .11!£__ ~ •PHONE PROVIDED A 7 .... AAIL BMCKET MOUNTING SURFACE ~ I B'-9" CLEAR HOISTWAY I ... 4'-41/2 4'-4112· I 7'-101/2" BACK TO aicKOF GUIDE RAILS I ~ 7'-3112" BETWEt:U ,,., ""'""' CHUI C, ~ cs, ~u,uc ,~co ~ 10 :/2 r--0• PJTFORM O 1/T 6'--8• MIN. CLEAR INSIDE _J ;:--rl N ~z u~ == c2~E ;;+-ua~ ~JC wu.iW ~ ~ f BUFFER · -ii ~ w §lliit: ;I=u.l~~ ]18~ ~to~~ ~,~~ I I I JI'i' -----t .. ' ---1r· ·1 CAR STATION-I : IT FRONT RIGHT E '(ii a:::,, J ifj HS g ::, I"' I Cl) :,: 0 'I 41-1112· I ~ 1-FACEOFRAIL a·..s· CLEAR oPNG. I 1·-1112~ I w " ui ~ ~ ~ . "' ~ ~ :i 5 ~ :i! a. ::i ~ ~ ~ ,;, ~ ,-. ,.,, - ltl m OPERATION: TAC32 CAR ENCLOSURE: _TKAP PLUNGER WEIGHT: 279 DOOR TYPE: 'ONE SPEED-RIGHT HAND CAR WEIGHT: 2940 PLATFORMTHK: 3 3/8 I FINISHED F':,OOR: BYOllfERS TELEPHONE: BY ELEVATOR COMPANY _j PITC'.ADOER: BY•ELEVATORCOMPANY P,OWER UNIT: EP-125 ' 25 HP l POWER SUPPLY: ,450 V 3 PH 60 CYCLES STARTING: SOLID STATE STARTING I GLOPU: 6719 'I GLOJ: 6440 JACK MODEL: 3S2 lWIN I OVERTRAVEL: s• TOP 10• BOTTOM PLUNGER O.D.: 3.875• .-'l WALL THK: ,25" CYLINDER 0.D.: 5.5825" I WALL·THK: .. 219" 'l-NET>'AREA, 23 56 SQ IN BOTTOM CAR RUN BY:. s• I CAR BUFFER STROKE: 2 1/2" BETWEEN PIT FLR. & CAR BOLSTER ON COMPRESSED BUFFER: 2'-4 _1f8• BUFFER REACTION (TYP. AT EACH BUFFER)• 171B2LBS. ---~ isPRING# I 75902 EST. WORKING PRESS. 314 PSI I SPRING CAP.I 10223 CAR S=3.27 FORMED L.-J ·8=5.429 FORMED L.-.J S=1.38 FORMED"I.-J FRAME 1=9.!32 CROSSHEA_D r=21,71 BOLSJE~ ' ,1=2.17 STILE ' A•1.85· 7GAx6.x2112" A•2.264 7GAx8-x23f4•· r•1.009 t•10G~ THE FOLLOWING CONDITIONS MUST BE MET BEFORE INSTAL1'ATION IS COMPLETED. AND ARE NOT INCLUDED IN THE ELEVATOR CONTRACT: 1. A PLUMB, PROPERLY VENTILATED HOISTW/\Y (ACCORDING TO CODE AND SIZES SHOWN) 2. ADE6.UA'TE SUPPORT FOR J~CK, GUIDE RAIL BRACKETS, AND BUFFERS (FOR REACTIONS SHOWN ). 3. HOISTWAY BARRICADES AND ALL CUTIJNG AND PATCHING TO INSTAU. HOJSlWAY ENTRANCES, SILLS, HALL'FIXTURES, OIL AND ELECTRIC LINES. 4. PIT LIGHTS AND SWITCH, CONVENIENCE OUTLETS wiTH GFCI PROTECTION PER NEC. NOTE: MUST BE CLEAR OF ALL ELEVATOR EQUIPMENT • 5. DEDICATED 120 VOLT,'15 AMP. SERVICE, ALONG WJTH TELEPHONE CIRCUIT WHEN REQUIRED, TO TERMINALS OF EACH REQUIRED CONTROLLER (AS LOCATED ON PLAN VIEW) FOR THE FOLLOWING: • CAR LIGHT AND ALARM CIRCU(TWITH GFCI PROTeCTION PER NEC ~ GROUP CONTROL WHEN REQUIRED ' NO!E:-~R~:~~~~:J~v~g:~i~~ ~~ ~~~~~g:~1~~:E~ ALARM CIRCUIT ANO 6. BRANCH CIRCUIT CONDlJCTOR SIZING, MATERIALS, AND INSULA-fJON (INCLUDING BRANi;H CIRCUIT OVERCURRENT PROTECTIVE.DEVICE) TO COMPLY WITH ALL LOCAL ELECTRICAL CODES. ___ AMPS STARTING CURRENT WITH A MAX. ALLOWABLE VOLTAGE DROP OF 10%. __ AMPS RATED t:;URRENT WITH A MAX. ALLOWABLE VOLTAGE DROP OF 5%, • THE STARTING CURRENT IS ADJUSTABLE FROM SHORT CIRCUIT CURRENT RATING 5~000 AMPS AT 600 VOL TS OR LESS 2 TO 4.5 TIMES THE MOTOR RATED A.C. AMPS. THE STARTING CURRENT OF 3 TIMES THE MOTOR RATED A.C. AMPS IS A NOMINAL STARTING CURRE,NT VALUE, (SEE NOTE 6), NOTE: ALSO, A FOURTH WIRE OF SAME SIZE AS THREE PHASE WIRES IS REQUIRED FOR GROUNDING P.URPOSES TO MINIMIZE ELECTRICAL NOISE INTERFERENCE. THE GROUNDING WIRE MUST BE CONNECTED TO THE BUILDINGS ELECTRICAL. SYSTEM GROUND. GEN: CONTRACTOR MUST FORWARD POWER REQUIREMENTS TO ELEC. 90NTRACTOR. 7. AN ENCL<;JSED MACHl"\E AREA (ACCORDING'TO CODE), WITH ADEQUA,:E LIGHT. HEAT, :~g ~~E~~g~J~~i~~Q'o~iLA~·:u~%~~N.CONOENSING HUMIDITY OF 10.90%), NOTE: MUST PROVIDE ~DEOUATlj DOOR,.SIZE TO'ALl.!JW INSTALLATION OF EQUIPMENT, OR LEAVE WALL OUT, UNTIL EQUIPMENT IS IN PLACE. 8. ENTRANCE WALL-WITH LINTELS MUST BE PROVIDED AFTER ENTRANCE FRAMES ARE SET OR LEAVE A ROUGH OPENING 15• WIDER AND 15" HIGHER THAN THE FRAME OPENING. SEE INSTALLATION PROCEDURES FOR FRAME·TO-V(ALL INTEREACE DETAl~S TO ENSURE CONFORMANCE WITH THE LABELEO,ENTRANCE INTEijFACE CONSTRUCTION. 9. POCKETS IN CORRIDOR WAU. (PER FIXTURE DRAWI_NGS) FOR HALL FIXTURES. NOTE: MUST BE LOCATED AS DIRECTED BY ELEVATOR CONTRACTOR 10. SMOKE SENSORS (AS REQUIRED). 11. CONDUIT ANO WIRING FROM HOISlvVAY TO ELEVATOR MONITORING PANELS (FOR SECURITY, LIF~, SAFETY, OR FIRE REQUIREMENTS) • 12. PIPE SLEEVES. TRENCHING, AND BACK FILLING FOR OIL AND/OR CONDUIT LINES AS SHOWN OR LOCATED BY ELEVATOR CONTRACTOR. CAR ~JATION: TRAOITl9Ji~_FIXTU_RES_,_ PUSHBJLTTONS MARKED,1, and 2 DOOR OPEN AND _(,':LOSE BUTTON§, l;_MERGENCY STOP SWII_CH, ALARM BUTTON FANILIGHT SWITCH, EMERGENCY LIGHT, TELEPHONE, BOX, Pl CAR RIDING LANTERN: RETURN RAIL FORCES F1 F2 SEISMIC RAIL FORCES ZONE 4 fF1 ±F2 498 LBS.· 349LBS. F1 = 1587 LBS.I F2 = 794 LBS. 15#T-RAILS DATE SYM. REylSION BY ICHKD. DESIGNED PERASME A17.1 2004 CODE. j DO NOT SCALE THIS DRAWING FOR: ARMY~NAVY ACADEMY ATHLETIC FACILITY I ELEV# 1 ADDRESS; 2605 CARLSBAD BLVD. TURNER CONSTRUCTION COMPANY I 3'-6" I •·-•· ROUGH OPNG I s· ~ r.a• BETWEEN CENTER LINE OF JACKS s 112· ~crrv~ CARLSBAD,CA 92008 I FJ".Z· 36 ARCHITECT: Reviewed for General Acceptance only. This review does not relieve the Subcontractor of the responsibility for making the work confonn to the requirements of the contract. The Subcontractor is responsible for all dimensions, correct fabrication and accurate fit with the work of other trades. SUBJECT TO ARCHITECTS APPROVAL BY: C. Rodriguez DATE: 03/08/2013 SPEC NO -PARAGRAPH DIV 142400 Part 1.4 A,B Submittal# 0001-142400-0 A_j HOISTWAY PLAN NOTE: IF DRYWALL CONSTRUCTION INSTALL FRONT WALL AFTER ENTRANCE FRAMES ARE SET. CONSULT ELEVATOR SUPT. FOR PIT SUMP LOCATION NOTE A: OIL PIPE LINES AND FITTINGS SHALL BE PROPERLY SUPPORTED TO RELIEVE STRAIN. I --------I NOTE B: ALL REACTIONS INCLUDE ALLOWANCE FOR IMPACT. PRELIMINARY 'FOR APPROVAL' NOTE C: THYSSENKRUPP ELEVATOR TO BE NOTIFIED OF ANY CHANGE TO ELEVATOR HOISTWAY OR MACHINE ROOM DESIGN. NOTED: ELEVATOR DESIGN & FABRICATION BASED ON ESTIMATED CAB WEIGHT SHOWN. LAYOUT --p;pj',ROVAL WILL BE CONSTRUEO AS FINAL CAB WEIGHT, UNLESS OTHERWISE NOTIFIED. GENERAL CONTRACTOR: TURNER CONSTRUCTION COMPANY ELEVATOR CONTRACTOR: THYSSENKRUPP ELEVATOR COMPANY EL CAJON, CA • I This drawing antralrinformation thereon is the proprietary property of ThyssenKrupp Elevator and must not be made public or copied. This drawing is loaned subject to return on demand and Is not to be used directly or Indirectly In any manner detrimental to the lnteresl of ThyssenKrupp Elevator. ThyssenKrupp Elevator Americas pAAwNI DATE I CHKD leAANcHI JS I 02/12/13 l I 37 I 1• ;;.:a~;:;;; JOB NUMBER I DAAWING NO. a,.ev.l,;HEET NO IL I I 1 OF1 ~' ,< NOTES THIS FRAME HAS A 2 HOUR WARNOCK HERSEY LABEL KEYHOLES 'l"O BE-OMITTED. ALUMINUM SILL TO BE SUPPLIED. MAXIMUM WHEEL LOAD FOR ALUMINUM SILL IS 625 LBS. DUSTCOVERS TO BE PROVIDED_- GC NOTE: GENERAL CONTRACTOR RESPONSIBLE FOR HOISTWAY REINFORCING AT FLOOR SLAB BEFORE INSTALLATION OF ENTRANCE FRAMES: MINIMUM OF 4" HIGH x.8" WIDE REINFORCED CONCRETE, REINFORCED Fll:LED B\.OCK, WOOD, OR Sl:EE_L l;lEAMS AT THE WAlL LINE ON E_ACH $IDE OF'OPENING REQUIRED FOR ANCHORING, SILL SUPPORT ASSEMBLY. REINFORCING TO BE LOCATED WITH RESPECT TO REACTION POINTS. REFERENCE INSTALLATION DRAWINGS 494JT, AND 494JV AijE AVAILABLE UPON REQUEST. . REACTIONS (LBS.) DUE TO LOAD~·ON DOOR PANELS. APPROX. HORIZ. LOADS AND LOCATIONS TO BUILDING SHOWN PER ASME A17.1, PART II. THE SPECIFIED LOADS ARE CONSIDERED IMPACTED. F;~E1-I _J_ 3'-6" CLE_AR OPE_Nl~G . ~ 2" FACE ~ : 3/4" T-" "B" ~ J_i_ 5" 3 7/16" 31/2" SILL LINE MIN. t DRYWALL TYPE FRAME TOTAL WEIGHT OF CAR DOOR & HALL DOOR = 388 LBS. . , 2 RIGHT HAND REQUIRED AT FLOOR 1,2 (FRONT) 16GA. L_ 1 7/8" 8" POCKET .3/4" N 3/16" f-::r: CJ iii ::r: ·CJ z z w ·a. 0 ::r: CJ ROUGH OPENING I I 4'-~" 0 '"" "'H ·-,w1nn-1 .I I~ I I ~- => 0 REACTIONS RAISED DOOR JAMB SYMBOLS co M 1ii ll. fl: (.) co "' ~ 11 l I ~ FINISHED 5" L WALL:;; SILL LINE MIN. i LINE ,:;! ' (.) "8"+31/2" I-6 21/16"DOOR -l~ co TO SILL , 1 3/16" DOOR I L 1/4"DOOR ~- TOFRAME 16GA. f-::r: CJ iii ::r: a:: CJ f-0 :?; ~ g m iii~ ll. ::r: f- 0 w a:: w :::0 0 :a.~ 0 ~ ~ u: LL ::I ~ a:: <( => <( a:: :a. w w z .J > -(.) 0 :a. a ~ ?fl .,.I .,.I .. 1 ...... co M721 SILL SUPPORT BY ELEVATOR COMPANY SECTION a:: ~ co FLOOR FRONT I REAR R1 R21 _j_ f ~ ·--------· -------re R1 c 2" BELOW I 11'-"' EAcmooR 3'-6" 3'-6" ~ ENTRANCE ELEVATION ONE SPEED RIGHT HAND DOOR & ENTRANCE ELEVATOR 1 (FRONT) WALL TYPE WALL SIZE (FRONT) WALL SIZE (REAR) FRONT I REAR ACTUAL I MIN. I MAX. ACTUAL MIN, I MAX. (LBS.). b77 '.,.,., 3/4" ROUGH OPENING TO BE FILLED IN BY GEN. CONTR.,AFTER ,FRAMES ARE SET 3'-6"'CLEAR OPENING 13/4" 3 7/16" 31/2" SILL LINE . 1/16" --' ! , 1 . T .COMBINATION·DRYWAl.:L/MASONRY TYPE FRAME PRELIMINARY 'FOR APPROVAL' FRAME FINISH DOOR FINISH FRONT I . REAR FRONT I REAR TURNER CONSTRUCTION COMPANY Reviewed for General Acceptance only. This review does not relieve the Subcontractor of the responsibility for making the work conform to the requirements of the contract. The Subcontractor is responsible for all dimensions, correct fabrication and accurate fit with the work of other trades. SUBJECT TO ARCHITECTS APPROVAL BY: C. Rodriguez SPEC NO -PARAGRAPH DIV 142400 Part 1.4 A,B DATE: 03/0!;!/2013 Submittal# 0001-142400-0 DATE I SYM. REVISION BY DESIGNED PERASMEA17.1 DO NOT SCALE THIS DRAWING FOR: A~MY-NAVY ACADEMY ATHLETIC FACILITY I ELEV# 1 ADDRESS: 2605 CARLSBAD.BLVD. CITY: CARLSBAD, CA 92008 ARCHITECT: GENERAL CONTRACTOR: TURNER CONSTRUCTION COMPANY ELEVATOR CONTRACTOR: THYSSENKRUPP ELEVATOR COMPANY EL CAJON, CA 92020 This drawing and all information thereon ls the proprietary property of ThyssenKrupp Elevator and must not be made public or copied. This drawing Is loaned subject to return on demand and Is not to be used directly or indirectly in any manner detrimental to the interest of ThyssenKrupp Elevator. ThyssenKrupp Elevator Americas DWN I DATE BRANCH JS I 02/12/13 37 JOB NUMBER DRAWING NO. I REV.I SHEET NO. E1 1 OF 1