HomeMy WebLinkAbout2604 EL CAMINO REAL; A; CB163604; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plumbing/Mechanical/Electrical (PME) Permit 09-21-2016 Permit No: CB163604 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: 2604 EL CAMINO REAL CBAD St: A PME Parcel No: 0000000000 Lot#: 0 Reference #: PC#: Project Title: Applicant: RUBIO'S: REPLACE GREASE TRAP SAME SIZE & LOCATION CGP MAINTENANCE & CONSTRUCTION 8614 SIESTA RD 92071 858 454-7326 Plumbing Fees Electrical Fees Mechanical Fees Other PME Fees TOTAL PERMIT FEES Owner: Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: ISSUED 09/21/2016 JMA 09/21/2016 09/21/2016 $163.00 $0.00 $0.00 $0.00 $163.00 Total Fees: $163.00 Total Payments To Date: $163.00 Balance Due: Inspector: FINAL APPROVAL Date: /t}....-/3-/p Clearance: $0.00 NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which ou have reviousl been iven a NOTICE similar to this or as to which the statute of limitations has reviousl otherwise ex ired. THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0PLANNING 0ENGINEERING BUILDING DFIRE DHEALTH ,., ~;cicyof Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 email: building@carlsbadca.gov www.carlsbadca.gov Plan Check No. CB( b. 0 '-0 Est. Value Carlsbad Plan Ck. Deposit Date t:f" • 20 · I SWPPP -A EL. CA-MINO SUITE#/SPACE#/UNIT# A APN 1~1-03 -01 LOT# PHASE# # OF UNITS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME OCC. GROUP RU6le.6 WI EXISTING USE DECKS (SF) FIREPLACE YES[J#_ NO CONDITIONING YESl:2:fNoD FIRE SPRINKLERS YESONoO PROPERTY OWNER \ 1<.UBIOS ADDRESS 1902 WE<-1 ~HT pL. STE 300 CITY STATE ZIP CARLS D CA -:2-008 PHONE FAX 7(,:,0 ·tut· 26"18 EMAIL DESIGN PROFESSIONAL CONTRACTOR BUS. NAME c~ ADDRESS ADDRESS CITY STATE ZIP CITY SA-NTE:e PHONE FAX EMAIL EMAIL ( I c,mo o STATE UC.# STATE UC.# s--ior (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500}). Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this pennit is issued. I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this pennit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co. Of= T HE \I\JE sr Policy No. W PL50 32% 5CO Expiration Date 1 '2 · :a I · J 0 This section need not be completed if the permit is for one hundred dollars ($100) or less. 0 Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure w ke 'compensation covera~e is . lawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, s as provided for in ction 37 of Labor code, interest and attorney's fees. _2$ CONTRACTOR SIGNATURE ·~~ •. Q~ "" 0AGENT DATE I hereby affinm that I am exempt from Contractor's License Law for the following reason: D D D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0Yes 0No 2. I (have I have not) signed an application for a building pennit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone I contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone I type of work): _2$ PROPERTY OWNER SIGNATURE 0AGENT DATE Inspection List Permit#: CB163604 Type: PME Date __ Inspection Item 10/18/2016 49 Final Mechanical 10/17/2016 29 Final Plumbing 10/14/2016 21 Underground/Under Floor 10/14/2016 29 Final Plumbing Thursday, October 20, 2016 Inspector Act RI PB AP PB AP RI RUBIO'S: REPLACE GREASE TRAP SAME SIZE & LOCATION Comments AM PLEASE Page 1 of 1 Location: Rubios # 29 2604-A El Camino Real Carlsbad, CA 92008 APN : 1670307600 Rubios Corporate 1902 Wright Place, Ste. 300 Carlsbad, CA 92008 (760) 529-2678 Scope of work: Pump existing grease trap. Demo approx. 16 SF of tile around grease trap. Demo approx. 16 SF of concrete around grease trap. Disconnect and remove existing Zurn 50/100 grease trap. Haul away and dispose at an approved off site location. Prep area to install new trap, modify existing plumbing to set new trap. Supply and install (1) new Canplas plastic trap model# 39SOA04 50/100. Connect new grease trap to existing plumbing and vents. Supply and install (1) flow control per local city code. of Carlsbad Buitding Division SEP 21 20l6 ;;o <I> co .:;;· -+-<I> ~ Supply and install (2) 6" plastic extensions to l~~PROVE~ BY: trap with floor. J-,A.,J'( Back fill around newly installed grease trap witl\S8l.lED BY __ (J[VfL__ ----- purpose sand. Pour new concrete around newly installed grease trap. Supply and install needed floor tile to patch around newly installed grease trap. Clean up work area and dispose of all related debris at an approved location. Contractor: CGP Maintenance & Construction 8614 Siesta Rd., Santee CA 92071 619-954-5931 PM Claudia Molloy Restrooms Prep area Steam table Salsa bar Cook area I I ~ 0 iJ 7' -, Kitchen <I> ::::I "'O -0 -, -, <I> <I> <I> 0 N CD -, Soda Lobby I I 3:: 0 "'O V, s· I L-....2S: Dry storag~ Office 1D *Drawing not to scale ro Q) 0:: 0 C E ro u -UJ • CBlb-3~o ura General Data Congratulations on your purchase of the Endura Grease Interceptor. The Endura Grease Interceptor was designed and built to last and comes with a 10-year warranty (valid only when the warranty card is filled out and returned to the manufacturer). Proper installation of a grease interceptor is critical to its efficient operation. Even the best designed grease interceptor will not operate efficiently if installed incorrectly. All installation recommendations are subject to the approval of the local code authority having jurisdiction. The Endura Grease Interceptor may be installed on the floor, partially in the floor, or fully recessed below the floor to best suit the situation. Whichever installation configuration is used, make sure you locate the grease interceptor in an area that allows for ease of maintenance. Placement should allow the cover to be easily removed for cleaning. A minimum clearance is required above the top of the Grease Interceptor to allow removal of the internal baffles for a complete cleanout (15/20/25/35 GPM -15'; 50 GPM -21 "). With the cover removed, all internal surfaces should be visible. This is necessary not only for access to clean the interceptor, but also to inspect the interior for potential problems. The Endura Grease Interceptor is marked with "IN and OUT" above the connections to ensure the grease interceptor is installed in the right direction. The grease interceptor should be installed as close as possible to the fixture(s) being served, as every foot of piping between the grease source and the interceptor is unprotected and a potential source for grease build-up. Installations requiring long runs of pipe [exceeding 25 feet (8m) ] to reach the interceptor are to be avoided. This precaution will reduce the possibility of the pipeline becoming clogged with grease before reaching the grease interceptor. Grease waste lines should be piped at a minimum slope of 1/4 inch per foot (6mm per 304mm) to maintain flow in the drain line. Dishwashers If local codes permit, the Endura Grease Interceptor can be connected to dishwashers. To prevent industrial grade detergents from compromising the efficiency of the system, a separate grease interceptor is recommended for each commercial dishwasher. The Plumbing and Drainage Institute (PDI) has done extensive testing on the effect of hot water on separation, and can support through data, the fact that hot water has little effect on separation efficiency. The Environmental Protection Agency (EPA), in their document EPA 625/R-00/008 (Design Manual: Onsite Wastewater Treatment Systems) is specific in recommending the use of hot water and proximity to the source to enhance retention of fat oil and grease (FOG). can pl as® ENGINEERING AND INSTALLATION MANUAL May2006 Food Grinder It is highly recommended that a solids interceptor be used in conjunction with the grease interceptor, especially when a food grinder is discharging into the drain line. A solid interceptor will prevent the grease interceptor from becoming plugged and will of the grease interceptor. If a solids interceptor is not installed, food grinder waste must bypass the grease interceptor, as rapid accumulation of solid matter will greatly reduce the grease interceptor's efficiency, preventing operation in compliance with the rated capacity. Piping Connections All Endura Grease Interceptors are manufactured with no hub connections. Standard mechanical joint couplings can be used to connect the grease interceptor to a metal or plastic piping system. If the piping system needs to be resized, use appropriate mechanical joint reducers, but do not decrease pipe diameter across the unit (i.e. 3 inch inlet, 2 inch outlet.) Please Note: The Endura Grease Interceptor is made of Polypropylene, which will not accept solvent weld cement.