2605 CARLSBAD BLVD; ; CB091323; Permit
10-15-2009 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB091323 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: Applicant: HOUSE AND DODGE DESIGN STE 200 1929 HANCOCK ST SAN DIEGO CA 92110 619557-0575 2605 CARLSBAD BL CBAD Tl Sub Type: COMM 2030410200 Lot#: 0 Status: ISSUED $57,225.00 Construction Type: VN __ Applied: 08/11/2009 Reference #: Entered By: RMA ARMY/NAVY ACADEMY-COTTAGES Plan Approved: 10/15/2009 6 & 7-STRUCTURAL RETROFIT 1635 SF-REMODEL & RELOCATE Issued: 10/15/2009 Inspect Area: Plan Check#: Owner: ARMY&NAVY ACADEMY CARLSBAD CALIFORNIA P 0 BOX 3000 CARLSBAD CA 92018 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee $454.83 Meter Size $0.00 Add'l Reel. Water Con. Fee $295.64 Meter Fee $0.00 SDCWA Fee $0.00 CFD Payoff Fee $12.02 PFF (3105540) $0.00 PFF (4305540) $0.00 License Tax (3104193) $0.00 License Tax (4304193) $0.00 Traffic Impact Fee (3105541) $0.00 Traffic Impact Fee (4305541) $0.00 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.00 MECHANICAL TOTAL $0.00 Master Drainage Fee Sewer Fee $0.00 Redev Parking Fee $0.00 Additional Fees $1.00 HMPFee TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $139.00 $20.00 $50.00 $0.00 $0.00 $0.00 $0.00 ?? $972.49 Total Fees:$972.49 Total Payments To Date:$972.49 Balance Due:$0.00 Inspector: DING PLANS IN STORAGE _ATTACHED FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE tlylf approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions fleTCaner coTecfjvSjr referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which YOU have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. •A<V »X Building Permit Application ^WJ 1635 Faraday Ave., Carlsbad, CA 92008 ^ CITY OF 760-602-2717/2718/2719 C* ADI C R A n^ Fax 76°-602-8558 V^ f\ |\ L. ^ D/\ L^ www.carlsbadca.gov J°BADDRESS 2605 Carlsbad Blvd CT/PROJECT* LOT*PHASE # # OF UNITS # BEDROOMS SUITE#/SPACE#/UNIT# # BATHROOMS TENANT A / • JU f] w i ) 4 }Plan Check No. ( A} U 1 U /S7 Est. Value <T7 ^J^ <? Plan Ck. Deposit 1 Q 5 x h tf Date/^ I ' ({I ' £}tf .A/-' IAPN | 203 - 041 - 02 - 00 BUSINESS NAME CONSTR rmy and Navy Academy TYPE OCC. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) Structural retrofit of existing 1,635 s.f. building "&$&$&} b+7 Remodel / relocate interior non-load bearing walls Replace (1) toilet with (1) urinal EXISTING USE living and office CONTACT NAME (If Different Fom Applicant) PROPOSED USE GARAGE (SF) living and office ADDRESS CITY PHONE STATE ZIP FAX EMAIL PROPERTY OWNER NAME . ... . .Army and Navy Academy ADDRESS 2605 CITY Carlsbad PHONE 760-729-2385 Carlsbad Blvd STATE ZIP CA 92008 FAX EMAIL ARCH/DESIGNER NAME & ADDRESS STATE LIC. # House and Dodge Design PATIOS (SF) DECKS (SF 491 APPLICANT NAME ADDRESS 1 FIREPLACE AIR CONDITIONING YES | |# NOfTI YES| iNPfTI FIRE SPRINKLERS House and Dodge Design 1929 Hancock Street, Suite 200 CITY STATE ZIP San Diego CA 92110 PHONE FAX 619-557-0575 619-557-0577 EMAIL scott@houseanddodge.com CONTRACTOR BUS. NAME ADDRESS CITY PHONE STATE ZIP FAX EMAIL STATE LIC.#CUSS CITY BUS. UC.# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of theBusiness and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). Workers'Compensation Declaration: I hereby affirm under penalty of perjury one of the foltowing declarations: LJ I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I 11 have and will maintain workers' compensation, as required bv Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co Policy No. Expiration Date This section need not be completed if the permit is for one hundred dollars ($100) or less. | | Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. DATE / hereby affirm that I am exempt from Contractor's License Law for the following reason: | [ |, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for saleji however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. I |Yes I ho 2.1 (have / have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number): 5.1 willprovide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): .^PROPERTY OWNER SIGNATURE DATE Is the applicant c-r future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? | |Yes I iNo Is the applicant or future building occupant required to obtain a permit from the air pollution control district or airguality management district? I JYes I I No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? I JYes FlNo IF ANY OF THE ANSWERS ARE YES,/ EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address I certify that I have read the application and state that the above information Is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: E ^APPLICANT'S SIGNATURE DATE City of Carlsbad Final Building Inspection Dept: Bunding Engineering Planning CMWD St Lite Firev\ Plan Check #: Permit #: Project Name: CB091323 ARMY/NAVY ACADEMY-COTTAGES Date: Permit Type: Sub Type: 02/16/2010 Tl COMM 6 & 7-STRUCTURAL RETROFIT 1635 SF-REMODEL & R Address: Contact Person: Sewer Dist: Inspected Bv: Inspected Bv: Inspected Bv: 2605 CARLSBAD BL Lot: 0 MILES WARNER Phone: 7608017147. CA Water Dist: CA Date Inspected: MI^I Date Inspected: Date Inspected: 0 [Y^^O v>-/^-^f^Ji-e^j^T \O Approved: Approved: Approved: Disapproved: Disapproved: Disapproved: Comments: City of Carlsbad Bldg Inspection Request For: 02/16/2010 Permit* CB091323 Title: ARMY/NAVY ACADEMY-COTTAGES Inspector Assignment: PY Description: 6 & 7-STRUCTURAL RETROFIT 1635 SF-REMODEL & RELOCATE INTERIOR NON-LOAD BEARING WALLS, Type:TI Sub Type: COMM Phone: 7608017147. Job Address: 2605 CARLSBAD BL Suite: Lot: 0 Location: Inspector: OWNER ARMY&NAVY ACADEMY CARLSBAD CALIFORNIA Owner: Remarks: Early first thing if possible, did norVopWr' QtO<* Total Time:Requested By: MILES WARNER Entered By: CHRITINE CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Comments Comments/Notices/Holds Associated PCRs/CVs Original PC# CV020453 CLOSED DIRTY, TRASHED BATHROOM; CV080648 CLOSED H- ILLEGAL CONST; PCR02049 ISSUED ARMY NAVY ACADEMY; DEFERRED TRUSS SUBMITTAL PCR02220 ISSUED ARMY NAVY REQUIREMENT; VERIFY CONSTR. CHANGES:ALL ADENDA/RFI'S PCR02287 ISSUED ARMY NAVY ACADEMY; TRANSMITTAL DATED 11/5/02 PCR03201 ABANDOND ARMY NAVY ACADEMY; ADDING 6-0/3-0 WINDOW PCR99178 ISSUED ARMY NAVY ACADEMY; CONVERT COPY ROOM TO OFFICE PCR99222 EXPIRED ARMY NAVY ACADEMY-REVISE; DISABLED ACCESS LOCATION & ACCESSABLE C Inspection History Date Description Act 01/28/2010 89 Final Combo NR 01/05/2010 17 Interior Lath/Drywall AP 12/21/2009 24 Rough/Topout AP 12/21/2009 84 Rough Combo AP 12/17/2009 14 Frame/Steel/Bolting/Welding PA Insp Comments PY PY PY PY EAST UNITS PY EAST UNIT EsGil Corporation In (Partnership with government for <Buif<fing Safety DATE: 10/13/O9 JURISDICTION: City of Carlsbad PLAN CHECK NO.: O91323 SET: IV PROJECT ADDRESS: 26O5 Carlsbad Blvd. PROJECT NAME: Remodel Cottage 6 & 7 Army and Navy Academy The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: XI Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person XI REMARKS: The clouded inked notes on sheet A-2 shall be made on city IV set. (at building department) By: David Yao Enclosures: EsGil Corporation D GA D EJ D PC 10/6 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 4 (858)560-1468 + Fax (858) 560-1576 EsGil Corporation In fanners/tip with government for (BuiCcCing Safety DATE: 9/29/09 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 091323 SET: III PROJECT ADDRESS: 2605 Carlsbad Blvd. PROJECT NAME: Remodel Cottage 6 & 7 Army and Navy Academy Q APEUCANT I REVIEWER a FILE The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. XI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Scott Esgil Corporation staff did not advise the applicant that the plan check has been completed. X Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Scott Telephone #: 619 557 0575 ext 14 Date contacted:^ /^ /^(by-r/^ Fax #: 619 557 0577 Mail Telephone Fax /" In Person REMARKS: By: David Yao EsGil Corporation D GA D EJ D PC Enclosures: 9/22 9320 Chesapeake Drive, Suite 208 4- San Diego, California 92123 * (858)560-1468 + Fax (858) 560-1576 City of Carlsbad 091323 9/29/09 RECHECK CORRECTION LIST JURISDICTION: City of Carlsbad PLAN CHECK NO.: 091323 PROJECT ADDRESS: 26O5 Carlsbad Blvd. SET: III DATE PLAN RECEIVED BY DATE RECHECK COMPLETED: ESGIL CORPORATION: 9/22 9/29/O9 REVIEWED BY: David Yao FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Building Code, Plumbing Code, Mechanical Code, Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. A. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. B. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. C. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? QYes QNo City of Carlsbad 091323 9/29/09 Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. SET III plan shows major revisions. The following items are new for the new revisions. 1. Per section 419.2, the walls between sleeping units shall have fire partition too. (1hr wall with % door) 2. Dimension on the plans the 30" clear width required for the water closet compartment and the 24" clearance required in front of the water closet. CPC 407.6. 3. Provide a note on the plans: The control valves in bathtubs, whirlpool bathtubs, showers and tub-shower combinations must be pressure balanced or thermostatic mixing valves. CPC Section 414.5 and 418.0. 4. Specify on the plans: Water conserving fixtures: New water closets shall use no more than 1.6 gallons of water per flush, lavatories and kitchen faucets may not exceed 2.2 GPM, and showers may not exceed 2.5 GPM of flow. CPC Section 402.0. 5. Provide smoke detectors at access for all sleeping rooms. 6. Provide revised structural plan to match the new architectural plan, (new headers, shear wall length revised..etc). 7. Provide complete plumbing plan to reflect all new plumbing fixtures. 8. Provide complete mechanical plan. (FAU size, location, damper requirement..etc). 9. Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub-panels. If the service is over 200 amperes, submit a single line diagram, panel schedules, and provide service load calculations. 10. Note on the plans that receptacle outlet locations will comply with CEC Article 210.52(A). City of Carlsbad O91323 9/.29/09 11 .Show at least one wall switch-controlled lighting outlet to be installed in every habitable room; in bathrooms. CEC Article 210.70(A). 12. All bedroom branch circuits now require arc fault protection. Note clearly on the plans that "Bedroom branch circuits will be arc fault circuit protected." CEC Article 210.12(B). 13. Per CEC Article 210.11 (C)3, note on the plans that bathroom circuiting shall be either a. A 20 ampere circuit dedicated to each bathroom, or b. At least one 20 ampere circuit supplying only bathroom receptacle outlets. 14. Provide plans, calculations or worksheets to show compliance with current energy standards.(new door and window openings at exterior wall) 15. Show on the plans compliance with the residential energy lighting requirements (Mandatory requirement) a. In bathrooms all fixtures must be high efficacy style or be controlled by a manually-on occupancy sensor. b- All other rooms require any installed fixtures to be high efficacy or be controlled by a manually-on occupancy sensor or dimmer. (Closets under 70 square feet are exempt). Note: Generally a high efficacy style of fixture is fluorescent complete with electronic ballasts. Regular incandescent, quartz halogen and halogen MR lamps do not comply. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Q Yes Q No The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact David Yao at Esgil Corporation. Thank you. EsGii Corporation i In (partners/Up with (government for (Buifafing Safety i DATE: 9/4/O9 JURISDICTION: City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: O91323 SET: II PROJECT ADDRESS: 2605 Carlsbad Blvd. PROJECT NAME: Remodel Cottage 6 & 7 Army and Navy Academy The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Scott Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Scott Telephone #: 619 557 0575 ext 14 Date contacted: 1/4/&1 (by^^ Fax #: 619 557 0577 Mail Telephone Fax ./'fn Person REMARKS: By: David Yao Enclosures: EsGil Corporation D GA D EJ D PC 8/31 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 City of Carlsbad O91323 9/4/09 RECHECK CORRECTION LIST JURISDICTION: City of Carlsbad PROJECT ADDRESS: 2605 Carlsbad Blvd. PLAN CHECK NO.: 091323 SET: II DATE PLAN RECEIVED BY ESGIL CORPORATION: 8/31 REVIEWED BY: David Yao DATE RECHECK COMPLETED: 9/4/09 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Building Code, Plumbing Code, Mechanical Code, Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. A. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. B. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. C. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? QYes QNo City of Carlsbad O91323 9/4/09 Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the requirements for new buildings, per Section 1134B.2. These requirements apply as follows: (The original submittal did not specify the use is office. The floor plan and name of the building appears to suggest the use of the building is dormitories. These disabled access requirements are apply to office remodel.) a) The area of specific alteration, repair or addition must comply as "new" construction. b) A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features. c) Existing sanitary facilities that serve the remodeled area must be shown to comply with all accessibility features. d) Existing drinking fountains (if any) must be shown to comply with all accessibility features. e) Existing public telephones (if any) must be shown to comply with all accessibility features. 2. If an unreasonable hardship finding is granted, priority should be given to those elements that will provide the greatest access, per Section 1134B.2.1 Exception #1. The order of priority shown below should be followed: a) An accessible entrance. b) An accessible route of travel. c) At least one accessible restroom for each sex. d) Accessible telephones. e) Accessible drinking fountains. f) When possible, additional accessible elements such as parking, storage and alarms. City of Carlsbad O91323 9/4/09 . To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Q Yes Q No The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact David Yao at Esgil Corporation. Thank you. PLUMBING, MECHANICAL, ELECTRICAL, and ENERGY COMMENTS PLAN REVIEWER: Eric Jensen PLUMBING (2006 UNIFORM PLUMBING CODE) 1. One water closet is being replaced by a urinal. Flush valve urinals are 15 fixture units each, a water closet only 2.5 fixture units. Please justify the existing water supply pipe sizing that will provide water to the (new) urinal or include a plumbing plan that shows the installation of new water supply piping (if necessary). The 2009 UPC (not yet adopted) allows the use of waterless urinals but only if a full size water supply pipe is provided. Provide a correctly sized water stub out or obtain City approval for a variance. Note: If you have any questions regarding this Electrical, Plumbing, Mechanical, and Energy plan review list please contact Eric Jensen at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. EsGil Corporation In Partnership -with (government for Quitting Safety DATE: 8/20/O9 JURISDICTION: City of Carlsbad PLAN CHECK NO.: O91323 SET: I PROJECT ADDRESS: 26O5 Carlsbad Blvd. PROJECT NAME: Remodel Cottage 6 & 7 Army and Navy Academy 1QANT "a JURIS. PLAN REVIEWER a FILE The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. X3 The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. XI Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Scott Telephone*: ^1^'5^^ Date contactecf/^^^bv^^f Fax #: 619 557 0577 Mail Telephone i/' FaxV/ln Person REMARKS: By: David Yao EsGil Corporation n GA n EJ PC Enclosures: 8/13 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576 City of Carlsbad 091323 8/2O/09 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 091323 OCCUPANCY: R-2 TYPE OF CONSTRUCTION: V-B? ALLOWABLE FLOOR AREA: SPRINKLERS?: ? REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 8/20/09 JURISDICTION: City of Carlsbad USE: dormitory ACTUAL AREA: STORIES: 1 HEIGHT: OCCUPANT LOAD: DATE PLANS RECEIVED BY ESGIL CORPORATION: 8/13 PLAN REVIEWER: David Yao FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2007 CBC, which adopts the 2006 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2006 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad O91323 S/2O/O9 Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: • Occupancy Classification(s) * Description of Use 4 Type of Construction * Sprinklers: Yes or No 4 Floor Area • Occupant Load 2. Provide a statement on the Title Sheet of the plans, stating that this project shall comply with the 2007 California Building Code, which adopts the 2006 IBC, 2006 UMC, 2006 UPC and the 2005 NEC. 3. Note on the plans: "All egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort." Section 1008.1.8. 4. Walls (new) separating dwelling units in the same building shall be fire partitions as required by Sections 708. Section 419.2. a) Such fire partitions and floors shall have a fire-resistance rating of not less than 1-hour (except in buildings of type IIB, NIB and VB Construction with automatic sprinkler systems, where the fire-resistance rating may be reduced to 1/2-hour). Section 708.3. b) Such fire partitions shall extend to the underside of the floor/roof sheathing above. i) In lieu of extending the wall to the floor/roof sheathing above, they may terminate at the fire-resistance-rated roof/ceiling assembly above. In this case, the space between the ceiling and the deck City of Carlsbad O91323 8/20/09 above shall be fire-blocked or draftstopped in accordance with Sections 717.2 and 717.3 at the partition line. Section 708.4. 5. Please refer to the following corrections for plumbing item. 6. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 7. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Q Yes Q No 8. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact David Yao at Esgil Corporation. Thank you. PLUMBING, MECHANICAL, ELECTRICAL, and ENERGY COMMENTS PLAN REVIEWER: Eric Jensen PLUMBING (2006 UNIFORM PLUMBING CODE) 1. One water closet is being replaced by a urinal. Flush valve urinals are 15 fixture units each, a water closet only 2.5 fixture units. Please justify the existing water supply pipe sizing that will provide water to the (new) urinal or include a plumbing plan that shows the installation of new water supply piping (if necessary). MECHANICAL, ELECTRICAL, and ENERGY • Are all fine as submitted. Note: If you have any questions regarding this Electrical, Plumbing, Mechanical, and Energy plan review list please contact Eric Jensen at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. City of Carlsbad 091323 8/20/09 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: O91323 PREPARED BY: David Yao DATE: 8/20/09 BUILDING ADDRESS: 2605 Carlsbad Blvd. BUILDING OCCUPANCY: R-2 TYPE OF CONSTRUCTION: V-B BUILDING PORTION remodel Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) cb Blda. Permit Fee bv Ordinance T Valuation Multiplier By Ordinance Reg. Mod. per city VALUE ($) 57,225 57,225 $419.85 Plan Check Fee by Ordinance i ' Type of Review: 0 Complete Review I I Repetitive FeeRepeats D Other i—I Hourly EsGil Fee Structural Only Hr. @ $272.90 $235.12 Comments: Sheet 1 of 1 macvalue.doc + City of Carlsbad Public Works - Engineering BUILDING PLANCHECK CHECKLIST DATE: BUILDINGADDI^ESS: _ PROJECT DESCRIPTION: ^_^__^ ASSESSOR'S PARCEL NUMBER: 2o V 'crt\ ^ PLANCHECK NO.:-(llZ e^t-i isr VALUE: ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. D A Right-of-Way permit is required prior to construction of the following improvements: )ENIAL Please see/*ne attached list of outstanding issues marked wKp D. Make necessary corrections to plans or specifications/for compliance with applicable codes ano^tarnJards^Submit corrected plans and/or specificatiohs to theEmilding Dept. for resubmittal to the Engineering'Dept/ Only the applicable sheets have been s Date: By: By: Date: Date: By: FOR OFFICj ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT; Date: D D D D D D D ATTACHMENTS Engineering Application Dedication Checklist Improvement Checklist Neighborhood Improvement Agreement Grading Submittal Checklist Right-of-Way Permit Application and Info Sheet Storm Water Applicability Checklist/Storm Water Compliance Exemption Form ENGINEERING DEPT. CONTACT PERSON Name: Address: Phone: KATHLEEN M. LAWRENCE City of Carlsbad 1635 Faraday Avenue, Carlsbad, CA 92008 (760) 602-2741 NOTE: If there are retaining walls associated with your project, please check with the Building Department if these walls need to be pulled by separate RETAINING WALL PERMIT. -Y314 •1635 Faraday Avenue • Carlsbad, CA 920O8 (76O) 6O2-2720 • FAX (760) 6O2-8562 ,ND RD3 D BUILDING PLANCHECK CHECKLIST SITE PLAN 1. Provide a fully dimensioned site plan drawn to scale. Show: B. North Arrow Existing & Proposed Structures Existing Street Improvements ,/fi. Property Lines (show all dimensioi)s) I. /E. Easements / Ix Right-of-Way Width & Adj Streets Driveway widths Existing or proposed sewer lateral Existing or proposed water service Existing or proposed irrigation service Submit on signed approved plans DWG No. D 2. Show on site plan: A. Drainage Patterns 1. Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. 2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." B. Existing & Proposed Slopes and Topography C. Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project. Each unit requires a separate service; however, second dwelling units and apartment complexes are an exception. D. Sewer and water laterals should not be located within proposed driveways, per standards. CD 3. Include on title sheet: Site address B./Assessor's Parcel Number Qi. Legal Description/Lot Number For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION Show all existing use of SF and new proposed use of SF. Example: Tenant Improvement for 3500 SF of warehouse to 3500 SF of office. A ST 2ND ORD BUILDING PLANCHECK CHECKLIST DISCRETIONARY APPROVAL COMPLIANCE D Q 4a. Project does not comply with the following Engineering Conditions of approval for Project No. D D 4b. All conditions are in compliance. Date: DEDICATION REQUIREMENTS D D 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 17.000 . pursuant to Carlsbad Municipal Code Section 18.40.030. For single family residence, easement dedication will be completed by the City of Carlsbad, cost $605.00. Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 W x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by: Date: IMPROVEMENT REQUIREMENTS D D 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ 82.000 pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: BUILDING PLANCHECK CHECKLIST A ST 2ND 3RD CH D 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $441.00 so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as follows: _ _ 6c. Enclosed please find your Neighborhood Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Neighborhood Improvement Agreement completed by: Date: D D D 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 15.16 of the Municipal Code. r\IDnT EH CH 7a. Inadequate information available on Site Plan to make a determination on ' grading requirements. Include accurate grading quantities in cubic yards (cut, fill import, export and remedial). This information must be included on the plans. CH CD E] 7b. Grading Permit required. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. D D 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) All required documentation must be provided to your Engineering Construction Inspector per the attached list. The Inspector will then provide the Engineering Counter with a release for the Building Permit. D D 7d. No Grading Permit required. PROJECT INSPECTOR: PROJECT ID: CITY OF CARLSBAD GRADING INSPECTION CHECKLIST FOR PARTIAL SITE RELEASE DATE: GRADING PERMIT NO. LOTS REQUESTED FOR RELEASE: N/A= NOT APPLICABLE •/= COMPLETE 0= Incomplete or unacceptable 1st »nd 1. Site access to requested lots adequate and logically grouped. 2. Site erosion control measures adequate. 3. Overall site adequate for health, safety and welfare of public. 4. Letter from Owner/Dev. requesting partial release of specific lots, pads or bldg. 5. 8 Vx x 11" site plan (attachment) showing requested lots submitted. 6. Compaction report from soils engineer submitted. (If soils report has been submitted with a previous partial release a letter from soils engineer referencing the soils report and identifying specific lots for release shall accompany subsequent partial releases). 7. EOW certification of work done with finish pad elevations of specific lots to be released. Letter must state lot(s) is graded to within a tenth (.1) of the approved grading plan. 8. Geologic engineer's letter if unusual geologic or subsurface conditions exist. 9. Fully functional fire hydrants within 500 feet of building combustibles and an all weather road access to site are required. EH Partial release of grading for the above stated lots is approved for the purpose of building permit issuance. Issuance of building permits is still subject to all normal City requirements required pursuant to the building permit process. CU Partial release of the site is denied for the following reasons: Project Inspector Date Construction Manager Date BUILDING PLANCHECK CHECKLIST MISCELLANEOUS PERMITS ,. ST 2ND 3RD D D D 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Wav and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-Way permit required for: D IH 9. INDUSTRIAL WASTE PERMIT If vour facility is located in the City of Carlsbad sewer service area, you must complete the attached Industrial Wastewater Discharge Permit Screening Survey. Fax or mail to Encina Wastewater Authority, 6200 Avenida Encinas, Carlsbad, CA 92011, (760) 438-3941, Fax (760) 476-9852. STORM WATER COMPLIANCE uires Project Storm Water Permit: PSP_ 2 - 0 ler II (Requires SWPPP) - Please complete attached formsn> Exempt - Please complete attached exemption form STORM WATER APPLICABILITY CHECKLIST D D D 10b. D Priority Project D Not required D D D H- D Required fees are attached D Drainage Fee Applicable Added Square Fee Added Square Footage in last two years? Permit No. Permit No. Project Built after 1980 Impervious surface > 50% yes Impact unconstructed fac. yes D Fire Sprinklers required yes no (is addition over 150' from CL) Upgrade yes no D No fees required It BUILDING PLANCHECK CHECKLIST WATER METER REVIEW .. ST D D D 12a. Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized. Oversized meters are inaccurate during low-flow conditions. If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used. • All single family dwelling units received "standard" 1" service with 5/8" service. • owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm). A typical fixture count and water demand worksheet is attached. Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit. • Maximum service and meter size is a 2" service with a 2" meter. D D D 12b. Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval. The developer must provide these calculations. Please follow these guidelines: If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets. If so, at the water meter station, the demand in gpm may be listed there. Irrigation services are listed with a circled "I", and potable water is typically a circled "W". 1. If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach). Typically the Planning Dept. Landscape Consultant has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use. Once you have received a good example of irrigation calculations, keep a set for your reference. In general the calculations will include: • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection BUILDING PLANCHECK CHECKLIST ..ST 2ND 3RD D D D 12c. Irrigation Use (where recycled water is available) 1. Recycled water meters are sized the same as the irrigation meter above. 2. If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development. For subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge. If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund. However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this. D D D 13. Additional Comments: ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET Address: Bldg. Permit No.. Prepared by: Date: Checked by: Date: EDU CALCULATIONS: List types and square footages for all uses. Types of Use: Sq. Ft./Units: EDU's: Types of Use: Sq. Ft./Units: EDU's: APT CALCULATIONS: List types and square footages for all uses. Types of Use: Sq. Ft./Units: ADT's: Types of Use: Sq. Ft./Units: ADTs: FEES REQUIRED: WITHIN CFD: D YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee)D NO D 1. PARK-IN-LIEU FEE PARK AREA & #: FEE/UNIT: X NO. UNITS: =$ Reso No. Line Item: D 2. TRAFFIC IMPACT FEE ADT's/UNITS: X FEE/ADT: =$ D 3. BRIDGE AND THOROUGHFARE FEE (DIST. #1 DIST. #2 DIST. #3. ADT's/UNITS: X FEE/ADT: =$ D 4. FACILITIES MANAGEMENT FEE ZONE: UNIT/SQ.FT.: X FEE/SQ.FT./UNIT: =$_ D 5. SEWER FEE EDU's: X FEE/EDU: =$_ BENEFIT AREA: EDU's: X FEE/EDU: =$_ D 6. DRAINAGE FEES PLDA : HIGH MEDIUM LOW_ ACRES: X FEE/AC: =$ D 7. POTABLE WATER FEES UNITS CODE CONNECTION FEE METER FEE SDCWA FEE IRRIGATION TOTAL OF ABOVE FEES*: $ Word\Doc*tMi*fom»\Fe« Calculation Workihoet Rev. 7/14/00 Qj £ o Q Q S CD (P tp Q. 0. Q. D D D D REDEVELOPMENT DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. Planner ^ . APN: T.py Hi -07- Address Phone (760) 434- Type of Project & Use: T«\ • Zoning:_General Plan: V Net Project Density:DU/AC CFD (in/out) #_Date of participation: Facilities Management Zone: |_ Remaining net dev acres: Circle One (For non-residential development: Type of land used created by this permit: ) Legend: [X] Item Complete I I Item Incomplete - Needs your action Environmental Review Required: YES N0^< TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: APPROVAL/RESO. NO. PROJECT NO. YES NO X TYPE DATE OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: NO Coastal Zone Assessment/Compliance Project site located in Coastal Zone?YES^7 CA Coastal Commission Authority? YES_ If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Habitat Management Plan Data Entry Completed? YES NO^X If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) Inclusionary Housing Fee required: YES NO ~7( (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 Site Plan: I I Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of- way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. D D D ODD D D Policy 44 - Neighborhood Architectural Design Guidelines 1. Applicability: YES NO > 2. Project complies YES NO Zoning: \^ JV\ 1. Setbacks: Front: Required Interior Side: Required Street Side: Required Rear: Required Top of slope: Required 2. Accessory structure setbacks: Front: Interior Side: Street Side: Rear: Structure separation: 3. Lot Coverage: i^j [A, Required Shown Shown Shown Shown Shown Required Required Required Required Required Shown Shown Shown Shown Shown 4. Height:Required Shown Shown D 5. Parking:Spaces Required r°Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown C3 CH CD Additional Comments, OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER H:\ADMIN\COUNTER\BldgPlnchkRevChklst DATE 6/H Rev 3/06 Carlsbad Fire Department Plan Review Requirements Category: TI, COMM Date of Report: 08-21-2009 Reviewed by: Name: Address: HOUSE AND DODGE DESIGN STE 200 1929 HANCOCKS! SAN DIEGO CA 92110 Permit #: CB091323 8LDG. DEPT COPY Job Name: ARMY/NAVY ACADEMY-COTTAGES Job Address: 2605 CARLSBAD BL CBAD TNfOMPTiBTF -The it^rn Y^uJiay^ubmitted.fQr^vjewisir^ymplete.. At ibis lime, this office cannot adequately conduct a review to deteimirjg,rxa»f44^it&L'^iUi mid[)[)TliM)l^^efijirHVr sl'rirrli'rfPi ' I'll iihi3 review carefully all comments attat^edfffease resubmit the necessary plans and/or specincafToT»H44i|h_changes "clouded", to this office £j6«*e^ewaiid approval. Conditions: Cond: CON0003629 [MET] ** APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. Entry: 08/21/2009 By: cwong Action: AP SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# HV# BP DATE Business NameARMY ? NAVY A&AP& Project Address ^Gc-S c-Aj*u_SEAc> £1 Mailing Address Project Contact Business Contact ^Y City -VD. CA-P.LSJ3AP City State CA State Telephone # Zip Code Zip Code APN# Plan File* Telephone # / f 1 Q \ ^™"»^*M " *^"1 ^_ x*rV*BT *• > ^i.,."I ^"* • » 1 ^^ ^!i / v-*' -o | ^^ The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT - HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. 5. Organic Peroxides 9. 6. Oxidizers 10. 7. Pyrophorics 11. 8. Unstable Reactives 12. 1. Explosive or Blasting Agents 2. Compressed Gases 3. Flammable/Combustible Liquids 4. Flammable Solids Water Reactives Cryogenics Highly Toxic or Toxic Materials Radioactives 13. Corrosives 14. Other Health Hazards 15. None of These. PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HMD): If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 1255 Imperial Avenue, 3 floor, San Diego, CA 92101. Call (619) 338-2222 prior to the issuance of a building permit. FEES ARE REQUIRED. Expected Date of Occupancy: / / YES NO Is your business listed on the reverse side of this form? (check all that apply).nnn nna B Will your business dispose of Hazardous Substances or Medical Waste in any amount? EJ Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds, 200 cubic feet, or carcinogens/reproductive toxins in any quantity? S Will your business use an existing or install an underground storage tank? ISI Will your business store or handle Regulated Substances (CalARP)? H Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? D CalARP Exempt Date Initials D CalARP Required Date Initials D CalARP Complete Date Initials PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer to any of the questions below is yes, applicant must contact the Air Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the issuance of a building or demolition permit. Note: if the answer to questions 3 or 4 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days prior to commencing demolition or renovation, except demolition or renovation of residential structures of four units or less. Contact the APCD for more information. 1.YES D NO 2. D 3. 4. nn Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD factsheet at http://www.sdapcd.ora/info/facts/permits.pdf, and the list of typical equipment requiring an APCD permit on the reverse side of this from. Contact APCD if you have any questions). (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? (Public and private schools may be found after search of the California School Directory at http://www.cde.ca.gov/re/sd/: or contact the appropriate school district). Will there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-friable asbestos? Will there be demolition involving the removal of a load supporting structural member? Briefly describe business activities:Briefly describe proposed project: I declare under penatty,pf perjury that to the best of my knowledge and belie /mane herein are true and correct. Name of owner or Authorized Agent Signature of Owner or Ailfosrized Agent Date FOR OFFICIAL USE ONLY:FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:. BY:DATE: EXEMPT OR NO FURTHER INFORMATION REQUIRED COUNTY-HMD APCD RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY COUNTY-HMD APCD RELEASED FOR OCCUPANCY COUNTY-HMD APCD HM-9171 (04/07)County of San Diego - DEH - Hazardous Materials Division MIKE SURPRENANT & ASSOCIATES Consulting Structural Engineers STRUCTURAL CALCULATIONS (Cottages 6 & 7) Project: Army and Navy Academy 2605 Carlsbad Boulevard Carlsbad, California 92008 Prepared for: House & Dodge Design 1929 Hancock St., Suite 200 San Diego, California 92110 Project No.: 07010 Date: September 17,2009 335 15th Street San Diego, California 92101 Tel. (619) 531.0757 MIKE SURPRENANT & ASSOCIATES Consulting Structural Engineers JOB. SHEET NO. _ CALCULATED BY_ CHECKED BY SCALE . OF DATE. DATE_ TABLE OF CONTENTS PAGE 3. PROJECT SCOPE ... 2- 2. DESIGN CRITERIA SUMMARY.... 5 3. DESIGNLOADS -.. 4 4. VERTICAL ANALYSIS: A. HORIZONTAL MEMBER DESIGN (BEAMS, HEADERS, JOISTS, ETC.)., — B. VERTICAL MEMBER DESIGN (COLUMNS, STUDS, ETC.) —- 5. LATERAL ANALYSIS: A. SEISMIC / WIND COEFFICIENTS ^> B. Wt, (DEADLOADS).... Co C. LATERAL LOAD DISTRIBUTION — D. LATERAL LOAD-RESISTING DESIGN: I. SHEARWALL DESIGN 1-^ II. CANTILEVERED STEEL COLUMN ELEMENTS — III., STEEL MOMENT FRAMES — 6. FOUNDATION DESIGN: A. CONTINUOUS FOOTINGS. B. SPREAD FOOTINGS... C. RETAINING WALLS D. SPECIAL SYSTEMS I. GRADE BEAMS II. DEEPENED PIERS 7. SCHEDULES... A. SHEARWALL SCHEDULE B. HOLD DOWN SCHEDULE C. SPREAD FOOTING SCHEDULE Mike Surprenant Job —&~?c^ & Associates Sheet No- fr=_of 12- Consulting Structural Engineers Calculated by Date. Checked by Date Scale PROJECT SCOPE Q Provide structural calculations for an elective lateral upgrade to two (2) existing one-story buildings (Cottages 6 & 7) located on the Army Navy Academy property at 2605 Carlsbad Boulevard, Carlsbad, California. Existing Cottages are constructed utilizing wood-frame construction with board & batten exterior walls. Proposed upgrade will consist of installing new 2x4 perimeter shearwalls within the interior of the buildings. Existing roof framing consists of conventional stick-frame construction and the foundation system consists of a raised-wood floor with concrete perimeter stem walls/footings. A vertical load analysis/evaluation was not performed as part of this service. Interior walls which are proposed to be removed/re-located appear to be non-bearing as it rektes to supporting the primary roof rafter system. These calculations have been prepared for the exclusive use of the Army and Naval Academy and their design consultants for the specific site listed above. Should modifications be made to the project subsequent to the preparation of these calculations, Mike Surprenant & Associates should be notified to review the modifications with respect to the recommendations/conclusions provided herein, to determine if any additional calculations and/or recommendations are necessary. Our professional services have been performed, our findings obtained, and our recommendations prepared in accordance with generally accepted engineering principles and practices. MIKE SURPRENANT & ASSOCIATES Consulting Structural Engineers JOB. SHEET NO. _ CALCULATED BY CHECKED BY SCALE 01D\0 OF.\7- DATE, DATE. SHEARWALL DESIGN Story Shearwalls ** Direction Unit Lateral Load, v =psf Gridline _J Tributary Area (This Level): Lateral Load (This Level): Lateral Load (Level Above): Shearwall(s) Length, L Unit Wall Shear, v = FX/L = Shearwall Type: Overturning: L = Uplift = plf ft. Holdown Anchor Type: Gridline ^— Tributary Area (This Level):. Lateral Load (This Level): Lateral Load (Level Above): Shearwall(s) Length, L Unit Wall Shear, v = FX/L = Shearwall Type: Overturning: L = Uplift =. plf ft. Holdown Anchor Type:D Gridline ^ Tributary Area (This Level): Lateral Load (This Level): Lateral Load (Level Above): Shearwall(s) Length, L = Unit Wall Shear, v = FX/L = \2-7 Shearwall Type: plf Overturning: L = Uplift =. ft. Holdown Anchor Type:D Total Load (All Levels), Fx=. ft. . sq. ft. Lbs — _ Lbs Lbs . Okay by Inspection Lbs Total Load (All Levels), Fx =. ft. 2-, Okay by Inspection Lbs Total Load (All Levels), Fx =. ft. Okay by Inspection Lbs Sq. ft. .Lbs Lbs _ sq. ft. _Lbs — Lbs PRODUCT 207 MIKE SURPRENANT & ASSOCIATES Consulting Structural Engineers SHEET NO. _ CALCULATED BY_ CHECKED BY SCALE OF ! DATE. DATE. Gridline _ Story Shearwalls H Ki —Direction Unit Lateral Load, v = ~%*'\~?i psf Tributary Area (This Level): (SV^)(ZT) ;=. Lateral Load (This Level): Lateral Load (Level Above): Shearwall(s) Length, L Unit Wall Shear, v = FX/L = | Is £>plf Shearwall Type: Overturning: Uplift = . L = Holdown Anchor Type: Gridline Tributary Area (This Level): Lateral Load (This Level): Lateral Load (Level Above):. Shearwall(s) Length, L Unit Wall Shear, v = FX/L = Shearwall Type:o Overturning: Uplift = L = Holdown Anchor Type: Gridline Tributary Area (This Level): Lateral Load (This Level): _ Lateral Load (Level Above): Shearwall(s) Length, L Unit Wall Shear, v = FX/L = Shearwall Type: (^_J Overturning: L - Uplift = ft. plf ft. plf ft. Holdown Anchor Type:i — i Total Load (All Levels), Fx=. ft. . Okay by Inspection Lbs Total Load (All Levels), Fx =. ft. . Okay by Inspection Lbs Total Load (All Levels), Fx =. ft. Okay by Inspection Lbs _ sq. ft. _Lbs — Lbs Lbs . sq. ft. .Lbs .Lbs Lbs . sq. ft, .Lbs Lbs Lbs PRODUCT 207 MIKE SURPRENANT JOB. SHEET NO.. &~l£>\& OF_ \p:L- Consulting Structural Engineers CAICIII ATKDRY DATE_ DATE_ RCAI e I4»T~ Storv Shearwalls Gridline A Tributarv Area (This Level) : ( 2V/z)(«.i Lateral Load (This Level): Lateral Load (Level Above): jti) Shearwall(s) Length, L = (M^rn^ L Unit Wall Shear, v = FJL = 1 1 M Shearwall Tvpe: (11 Overturning: L = Uplift = Holdown Anchor Type: i — i Gridline » Tributarv Area (This Level): ( *7z)( 1 ^ Lateral Load (This Level): Lateral Load (Level Above): (-M.1- Shearwall(s) Length, L =(•&?&. 4* Unit Wall Shear, v = F,/L = \ *& & Shearwall Type: (\9 Overturning: L = Uplift = Holdown Anchor Type: i — i Gridline Tributarv Area (This Level): Lateral Load (This Level): Lateral Load (Level Above): Shearwall(s) Length, L = Unit Wall Shear, v = F,/L = Shearwall Tvpe: ( f Overturning: L = Uplift = Holdown Anchor Type: i — i ^ -UJ Direction Unit Lateral Load, v = l=>-\~£ psf O "BLfl sq.ft. ?,\fc\e=> Lbs Lbs ^•"^ Total Load (All Levels), F, = 2,1^^5 Lbs <£' _4-\\^=2^>-6l^ft. plf ft. v Okay by Inspection Lbs + ('v}l&£)- •• \{*=>^> sq.ft. H , 2/5.^ Lbs — Lbs ~^>\ Total Load (All Levels). F,= H>2&? Lbs j*'\\t—7.'3>&ls ft. plf ft. v Okay by Inspection Lbs sq.ft. Lbs Lbs Total Load (All Levels). F, = Lbs ft. plf ft. Okay by Inspection Lbs PRODUCT 207 MIKE SUKPKENANT & ASSOCIATES Consulting Structural Engineers JOB. SHEET NO._ CALCULATED BY_ CHECKED BY SCALE DATE. DATE. SCHEDULES D PRODUCT 207 ^^^ SHEARWALL SCHEDULE DESCRIPTION SYMBOL <D ® (z) 0 \tf <*> 0 VALUE 260 340 350 550 130 #10 1340 SPEC.® INSP. REQ'D NO NO YES YES YES YES YES MATERIAL 3/8' APA RATED SHEATHING 15/32' STRUCTURAL 1 RATED SHEATHING 3/8' APA RATED SHEATHING 3/8' STRUCTURAL 1 RATED SHEATHING 3/8' STRUCTURAL 1 RATED SHEATHING 15/32' STRUCTURAL 1 RATED SHEATHING 15/32' STRUCTURAL 1 RATED SHEATHING ( APPLIED TO (g) BOTH SIDES Or WALL; 3x © FRAMING REQ'D NO NO NO YES YES YES YES SHEARUJALL NAILING®® NAIL M » 8d 8d 8d * I0d BHIEH 6' b' 4' y r r r PM 12' 12' 12' 12' 12' 12' 12' SHEAR TRANSFER SILL ATTACHMENT©©® 5/8'+ AB. SPACING ®® 48' OC. 32' O.C. 32' O.C. 24' O.C. 16' O.C. 16' O.C. 8' O.C. BOTTOM PLATE® NAILS < LAGS I6d « 4' O.C. Ifcd « 4' O.C. \bd 9 4' OC. 5/8'* X 8' LAGS « Ifc" O.C. CSTAGGERED TO 4x BLK'G; 5/8'* X 8' LAGS « 12' O.C. (STAGGERED TO 4x BLK'G> 5/8't> X 8' LAGS « 12' O.C. (STAGGERED TO 4x BLK'G; 5/8'* X 8' LASS « 8' O.C. (STAGGERED TO 4x BLK'G; TOP PLATE CLIPS A35 « 16' OC. A36 « 12' O.C. A35 « 12' O.C. A35 • 8' O.C. LTP4 « 8' O.C. LTP4 « 8' OC. LTP4 « 6' OC. SHEARUJALL SCHEDULE FOOTNOTES: 0 ANCHOR BOLTS MUST BE EMBEDDED T MINIMUM INTO NEW CONCRETE, UNLESS NOTED OTHERWISE. UWERE SHEAROIALLS ARE TO BE ATTACHED TO EXISTING CONCRETE, &/»'«• THREADED ROD ANCHORS SHALL BE EPOXIED WITH S1 MINIMUM EMBEDMENT NTO THE EXISTING FOOTINGS AT THE SPACING INDICATED N ABOVE SCHEDULE. USE SIMPSON 'SET' EPOXY, CC-ESR-IT12. CSPECIAL INSPECTION FK3UIRED.? (?) SILL PLATES TO BE ATTACHED USING A MINIMUM OF (1) ANCHOR BOLTS PER PIECE WTH ANCHOR BOLTS LOCATED 4-3/8' MINIMUM 4 D' MAXIMUM FROM EACH END. (D ANCHOR BOLT HOLES TO BE DRILLED 1/32' MAXIMUM OVERSIZED. ; @ FOUNDATION ANCHOR BOLTS IN ALL SHEARWALLS SHALL INCLUDE STEEL PLATE WASHERS, A MNIMUM Or 0229 INCH BY 3 .INCHES BY 3 INCHES IN SIZE/BETOKEN THE SILL PLATE AND NUT. THE HOLE IN THE PLATE WASHER IS PERMITTED TO BE DIAGONALLY SLOTTED WITH A WIDTH UP TO 3/16 INCH LARGER THAN THE BOLT DIAMETER AND A SLOT LENGTH NOT TO EXCEED 1-3/4 INCHES, PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND THE NUT. (SIMPSON •BPSH-3' ACCEPTABLE). THE NUTS SHALL BE TIGHTENED .JUST PRIOR TO COVERING UMLL FRAMING. ® USE DOUGL AS FIR NO. 2 PRESSURE TREATED SILL PLATES. ENGINEER TO BE NOTIFIED FOR RE-DESIGN F OTHER SPECIES OF SILL PLATES ARE USED OR ARE PART OF THE EXISTING BUILDING. © UWERE NOTED, FRAMING AT FOUNDATION SILL PLATES, AND ALL FRAMING MEMBERS RECEIVING EDGE NAILING FROM ABUTTING PANELS, SHALL BE 3x NOMINAL OR THICKER, ALL SILL PLATE AND SHEATHING JOINT j NAILING SHALL BE STAGGERED. @ SHEAR PANELS SHALL BE APPLIED DIRECTLY TO STUD FRAMING AT 16' ON CENTER MAXIMUM. SHALL BE STAGGERED. ® ALL WOOD SHEATHING PANEL EDGES SHALL BE BLOCKED WITH MINIMUM 2x BLOCKING, UNLESS NOTED OTHERWISE @ SHEARWALLS WITH MORE THAN ONE VERTICAL PANEL IN HEIGHT SHALL HAVE EITHER VERTICAL OR HORIZONTAL STAGGERED SPLICED JOINTS. . (¥) ONLY COMMCN NAILS ARE TO BE USED FOR ALL SHEATHING ATTACHMENT. NAIL <3JN» USING 'CLIPPED HEAD' OR 'SINKER' NAILS ARE NOT ACCEPTABLE @ PROVIDE 3/8' MINIMUM EDGE DISTANCES FOR ALL SHEATHING AND FRAMING MEMBER EDGE NAILING. ® PERIODIC SPECIAL INSPECTION IS REQUIRED PER IBC SECTION \\ff\3.MIKE SURPRENANTfF\f & ASSOCIATES-It, \A^_ Consulting Structural Engineersv> rp : h [ I j c 1I ! 3 n; c 0 o rn 0a R , ?i 3 S O •n 1 > Xfc > J o .—1o MIKE SURPRENANT & ASSOCIATES Consulting Structural Engineers JOB_ SHEET NO.. CALCULATED BY_ CHECKED BY SCALE OF_! Z DATE. DATE. HOLD-DOWN SCHEDULE 4x POST uV MSTC40 FLR-To-FLR HOLD-DOWN 4x POST LU/ MSTC52 FLR-Tc-FLR HOLD-DOWN 4x POST LU/ -MSTC66 FLR-To-FLR HOLD-DOWN 4x POST LU/ MSTC48B3 HOLD-DOWN (JO 4x MiN. BEAM BELOW LU/ MIN. 38 !0d TO POST; 4x POST LU/ STHDIO HOLD-DOWN 4x POST LU/ HDU2 HOLD-DOWN ON SSTB16 A.B. 4x POST LU/ MDU4 HOLD-DOWN ON SST520 A.B. 4x POST LU/ HDU5 HOLD-DOWN ON SSTB24 A.B. 6x POST LU/ HDU8 HOLD-DOWN ON SSTB28 A.B. 6x POST LU/ HDU1I HOLD-DOWN ON SB1x30 A.B. 6x POST LU/ HDU14 HOLD-DOWN ON SBtx30 A.B. i| HOLD DOWN ANCHORS MUST BE TIED IN PLACE PRIOR TO FOUNDATION INSPECTION. 2) DEEPEN FOOTINGS TO PROVIDE 3" MiN. CONCRETE COVER WHERE HOLD DOWN ANCHORS ARE LONGER THAN THE FTG DEPTH. 3; USE (Rj; OPTION ON STHD HOLD-DOWNS FOR RAISED WOOD SUB-FLOOR CONDITION. 4) MSTC HOLD-DOWNS MAY USE i6d SINKERS OR iOd COMMON NAILS. 5) MSTC MOLD-DOWNS TO BE CENTERED BETWEEN UPPER i LOWER FLOORS. MAXiMUM CLEAR SPAN = 16*. NAILS NOT REQUIRED IN CLEAR SPAN ^RiM 50ARD; AREA. IO|lM/OQ CB091323 2605 CARLSBAD BL ARMY/NAVY ACADEMY-COTTAGES K a. V_CTOI irri IRAI RETROFIT 1FOT RF-RFMODEL & Approved Bunding Planning Engineering Fire p:^Date Forms/Fees FOG HazMat/APCD Health Comments Building Planning Engineering Fire Date Date Need? ILM IT Application Complete? Y N Fees Complete? Y N