HomeMy WebLinkAbout2606 GALICIA WAY; ; 80-30; PermitLICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provI
slons of Chapter 9 (commencing with Section
7000) of Division 3 of the Business.and Protes-'
slons Code, and my license is in full force and at-
fact.
OWNER-BUILDER DECLARATION
Dl hereby affirm that I am exempt from the Con-
tractor's License Law for the following reason
(Sec. 7031.5,Business and Professions Code), Any
city àr county which requires a permit to con-
struct, after, improve, demolish, or repair any
structure, prior to Its issuance also requires the
applicant for such permit to tile a signed state-
ment that he is licensed pursuant to the provi-
sions of the Contractor's License Law (Chapter 9
commencing with Section 7000 of Division 3 of
the Business and Professions Code) or that i ex-
empt therefrom and the basis for the alleged ex-
emption. Any violation of Section 7031.5 by an ap-
plicant for, a permit subjects the applicant to a
civil penalty of not more than five hundred dollars
($500).
Dl, as owner of the property, or my employees
with wages as their sole compensation, will do
the work, and the structure Is not intended or of-
fered for sale (Sec. 7044, Business and Profes-
sions-Code: The Contractor's License Law does
not apply to an owner of property who builds or
improves thereon and who does such work
himself or through his own employees, provided
Ihat such Improvements are not intended or of-
fered for sale. If, however, the building or Improve-
ment is sold within one year of completion, the
owner-builder will have the burden of proving that
he did not build or improve for the purpose of
sale).
DI, as owner of the properly, am exclusively con-
trading with licensed Contractors to Construct
the project (Sec. 7044, Business and Professions
Code: The Contractor's License Law does not ap-
ply to an owner of property .ho builds or Im-
proves thereon, and who contracts for such pro-
jects with a contractor(s) license pursuant to the
contractor's License Law). - -
I am exempt under Sec. , B. & P.C.
for this reason_________________________________
Date ______________ Owner
WORKERS' COMPENSATION LCL19TION
I hereby affirm that I have a cel)lUcØ of con-
sent to self-insure, or a certlficetg"Work'
Compensation Insurance, ofLa I'ç4ified \c'
thereof (Sec. 3800, Labor CJ(.
POLICY NO.
COMPANY
OCopy is filed with the city.
OCertified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed If the per-
mil is for one hundred dollars ($100) or less).
'I certify that in the performance of the work for
wI,Ich this permit is Issued, I shall not employ any
peT.%,)n in any manner so as to become subject to
the Workers' Compensation Laws of California.
NO ICETO APPLICANT: If, after making this Cer-
tifIcate ot(,*'empion, you should become subjóct to Workers' Compensation provisions of the La de, you must forthwith comply with such
provi'0, this permit shall be deemed revoked.
'~`4"O' UCTION LENDING AGENCY
I h b 3Iffirm that there Is a construction len- ding a0encY or the performance of the work for
Whjhj is Issued (Sec. 3097, Civil Code).
W . APPLICATION & PERMIT USE BALL POINT .PEN.ONLY
'-
1200 ELM AVENUE (714) 438-5525
joe ADDRESS - AV. ST. NO. ,oL RD DATE OF APPLICATION Bus. LICENSE
/9
PERMIT NUMBER
OWNER - OWNER'S PHONE ', PRIME CONTRACTOR L-.- Til-itfr STATE LICENSE
OWNER'S /MAILING ADDRESS . CONTRACTOR"S ADDRESS. CONTRACTOR'S .
PHONE .. 6. U U r
. .
.
- -
Not Valid Unless Machine Certified
LOT I BLOCK
, - I
ASSESSORS PARCEL DESIGNER ' STATE LICENSE~ld
DESCRIPTION' OF WORK " - ,
DESIGNER'S ADDRESS DESIGNER'S PHONE
CENSUS TRACT GP LAND USE * ' , ZONING ' RES. UNITS - PRKING SPACE sf NUMBER OF STORIES
BLDG 50. FT. BLDG USE 0cc. GP STANDARD PLAN S . PLANI D S TYPE CDNST 0CC. 'LOAD
VALUATION: '- -
- AMT,
INSTILL FURN. DUCTS UP TO'lOO,OOO BTU
VENT FAN SINGLE DUCT
CITY. -PLUMB ING'PERMIT - - AMT. QTY. MECHANICAL PERMIT '
. EACH FIXTURE TRAP '-
EACH BUILDING SEWER .3'-O 100,000 BU .4O -C
-1 EACH WATER HEATER AND/OR VENT' ' --g- /OILER/COMPRESSOR UP TO 3 HP
EACH GASSYSTEM I T04 OUTLETS ' BOILER/COMPRESSOR 3-15 HP
-
EACH GAS SYSTEM 5 OR'MORE . , , BOILER/COMPRESSOR 16-30 HP
EACH INSTAL., ALTER, REPAIR WATER PIPE . 3
- EACH LAWN SPRINKLER SYSTEM . ' . ''MECH EXHAUST - H000/OUCTS-- .
WATER SOFTNER : 2.-O' ' RELOCATION OF EA FURNACE/HEATER . 'LDING PERMIT 3.00 Issue 3-.00 SIG ERMIT
. TOTAL PLUMBING
CONTRACTOR
. 3 '_.
010
- .
JOTAL MECHANICAL -,
. CONTRACTOR ' -.
60
-
PLAN CIK
ALL INCLU(EPERMIT - • - ' 1 I .'
ciTY., - ELECTRICAL PERMIT - AMT. . QTY. . '-MOBILE HOME PERMIT - ' AMT.
TOTALPLUM:ING
ELECTRICAL
,
,
NEW CONST EA AMP/SWT/BKR .5g. AWNING - . ' - .- . ' 'MECHANICAL . '• I
- 1 PH .25 ' 3 PH . - PORCH ' . . MOBILE HOME
EXIST BLDG EA AMP/SWT/BKR - . ' . SET-UP - , - . . - . SOLAR -.
- 1 PH .25 3 PH .
-
RAMADA, CABANA - . . . . I ' I I •' I -
-
REMODEL/ALTER PER CIRCUIT .
- FENCE OVER 6'
_TEMP POLE 200 AMPS . - TOTAL MOBILE HOME -. ' -- -: - ' MICO-FILM
- OVER 200 AMPS - . . , - . ' -• " ' ' - - - - ' I I
-
TEMP OCCUPANCY (30 DAYS)
'Issn' ,. 2:00
TOTAL ELECTRICAL .
CONTRACTOR .57 . . . . TOTALFEES PAYABLE '
I /ØCjO
I HAVE CAREFULLY EXAMINED THE COMPLETED "APPLICATION AND PERMIT, AND DO
HEREBY CERTIFY THAT ALL INFORMATION HEREON IS TRUE AND CORRECT AND I
FURTHER CERTIFY AND AGREE IF A PERMIT IS ISSUED: TO COMPLY WITH ALL CITY,
COUNTY AND STATE LAWS GOVERNING BUILDING CONSTRUCTION, WHETIER
SPECIFIED HEREIN OR NOT. -I,ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARM.
LESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND
EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE
OF THE GRANTING OF THIS PERMIT. , .
'AN OSHA PERMIT IS REQUIRED FOR EXCAVATIONS OVER SCHOOL FEES 5-0_DEEP AND DEMOLITION OR CONSTRUCTION OF .
STRUCTURES OVER 3 STORIES IN HEIGHT - -
- -' -
[;~~TURE. OWNERS CONTRACTOR A PR VIED BY
/ , 7
INSPECTION DATE - INSPECTOR
WOOD FLOOR
-FOUNDATION a FORMS • SET BACK • TOILET
UNDER FLOOR PLUMBING
UNDER FLOOR HEATING
OK TO INSTALL SUB FLOOR
SLAB FLOOR -
UNDER SLAB PLUMBING
FOOTING *,FORMS * SETBACK • TOILET
OK TO POUR CONCRETE-
FRAME
ROUGH ELECTRICAL
ROUGH PLUMBING -
ROUGH HEATING/VENTILATING
FRAME OK .PLACE INSULATION
INSULATION OK • PLACE WALLBOARD
WALLBOARD OK. PLACE TAPE
EXTERIOR LATH OK • PLACE STUCCO
-
FREPLACE
DAMPER & STEEL -
PLATE TIES/HEIGHT OF CHIMNEY
OTHER
TEMP POWER (POLE)
SEWER
GAS TEST
SWIM POOL • -STEEL BONDING
-
• PRE DECK
FENCE PREPLASTER
SHOWN • FRAME
-.PAN -
FINAL INSP BY BLDG DEPT -
OTHER DEPT'S REQ COMPLETED
ELEC METER—PERM—TEMP
GAS METER—PERM—TEMP
- CERTOFOCCUPANCYISSUED -
/ -
-
-
-----.
--
--
-, -
-- --
-r •
-.
- -
ITE --
ADDRESS: - •- OWNER: PERMIT NO: -
FIELD INSPECTION RECORD
REQUEST FOR INSPECTION TIME:________
INSPECTOR _1\ M PERMIT. NO.______________ DATE:
PWNER (;42 CV-1fJ5
ADDRESS
BUILDING
El FOUNDATION
El REINFORCING STEEL
El MASON RY
EJGROUT-GUNITE
El FLOOR AND CEILING FRAME
El SHEATHING
El FRAME
El EXTERIOR LATH
El INSULATION
El INTERIOR LATH OR DRYWALL
FINAL
PLUMBING I
El UNDERGROUND PLUMBING
El UNDERGROUND WATER
El ROUGH PLUMBING
El TOP OUT PLUMBING
El SEWER AND PL/CO
El TUB OR SHOWER PAN
El GAS TEST
WATER HEATER
FINAL
I ELECTRICAL
El TEMPORARY SERVICE
El ELECTRIC UNDERGROUND
El ROUGH ELECTRIC
El POOL BONDING
ElELECTRIC SERVICE
Cl CEILING HEAT
El G.F.I. 'Ivy SMOKE DETECTOR
FINAL
I MISCELLANEOUS 1
El PLENUM AND DUCTS
El COMBUSTION AIR-
0 PATIO
E_-).SIGN
El GRADING
El DRIVEWAY
El CONDITIONED AIR SYSTEMS
PREFER PIPING
FINAL
READY FOR INSPECTION: OMONDAY OTUESDAY DWEDNESDAY • THURSDAY 0 FRIDAY'
o A.M.
0 P.M.
SPECIAL INSTRUCTIONS
REQUESTED BY PHONE NO._________________
PERSON TAKING REPORT_fr
I
) &A4
rttftra1 nf ør r upau r
I CI TY OF CARLSBAD
••• This Certificate zsued pursuant to the requirements of Section 306
of the Uniform Buildi ng Code certifies that at the time of issuance
this structure comphes wth apphcabe ordnances of the City
regulating budding construction use. S
Al Use Classification Single Family Dwelling Bldg Permit No. 80-30
Group • Type Construction • Fire Zone • Use Zone •_•_•_•
•
0
Occupant Load 0
Owner of Building_
Jerry L Collins __Mdress 2606Galicia__Way
• • S • Building Address ici _War0 _•.Car)sbad,.___CA __920b8 •
< _____________________ -•________
......7f
___________-
• • NOTE. Alterations, changes, additions or changes of occupanc/nullefies t certificate. S
(Post in conspicuous place)
)VW T' 7 Y' V 7VV 'V V '' V\' A'V7V''IX
SAN D1EGUIT0 ENGINEERING, INC ' John B. Fox - P.E: •. '. •. . CIVIL ENGINEERING
Stephen-D. Dillemuth - P.E. .. AVENIDA DE ACACIAS . ... . . SURVEYING
P.O. BOX 2004 RANCHO SANTA FE CA 92067 SOIL TESTING
756-1861 756-3064
SDEl77
October 11, 1979.
Jerry Collins . . .. . . f ..., '. .
7600.. Primavera Way . . . .,
Carlsbad, CA: 92008
SUBJECT: Report of Limited Soil Reconnaissance for a proposed,: .
residence on Lot 75, La Costa South',Unit 1, iViap 5168,
Carlsbad, California. . . . . ..,
Gentlemen:
In accordance with your request, we have performed a limited,
reconnaissance on Galicia Way La Costa, Carlsbad, California.
In general, we have found the, site suitable for ,the proposed
development, provided the recommendations presented herein'are
incorporated into the site development. .. . .
GENERAL SITE DESCRIPTION
. . .
The site consists of a relatively flat portion near the street
sloping to a Northwesterly flowing drainage swale. There was no..
evidence.pf significant surface flow during recent 'years. Slopes
in the drainage areas varied from approximately 12 to 25%.
Vegetation consisted.of short native grasses on the flat Southern
portion and native brush in the draiiñáge'area. No man-made structures
or improvements were observed on the site.
I .
SDE: 1774 , October Ii, 1979 Page Two
It is understood that a single family residence, partly slab on
grade and partly stem wall and wood floor is to be constructed
on the site No retaining walls were shown on the approved plans
provided to this office The approximate configuration of the
site is shown on Plate No 1
Soils encountered in two hand dug borings excavated on the site
consisted generally of buff to tan slightly silty fine to medium
sandstone Approximate locations of the borings, excavated to a
maximum depth of three feet are shown on the attached Plate No
: 1. Detailed logs of the borings were recorded on the siteduring
the excavation and are presented on Plate No 2 Soils were class-
ified visually according to the Unified Soil Classification System,
a general description of which is presented on Plate No. 3.
LABORATORY AND FIELD TESTING
Tests performed on soil samples to determine existing and probable
future conditions were: (1) Maximum Dry Density, (2) Field Dry
Density, and (3) Direct Shear Tests. Procedures and results of
the. tests are as follows: . . . . . . .
(1). AMaximum Dry Density Test was performed on a representative
sample returned to the lab. The purpose of the test was to provide
a basis of comparison for existing field conditions and for probable
conditions after the proposed grading. The results of the test
performed in' accordance with A.S.T.M. Test Method D-1557-70, are as
follows: . .
Sample Location Maximum Dry Density (gm/cc) Optimum Moisture (%)
T-1 @ l ft. 1.850 12.5
(2) A Field Dry Density Test was performed on a representative sample
to determine the existing condition pf the proposed foundation 50115f
.1
."ISDE'1774
-
October ll,S4l979 . .' Page Three
The relative density is defined as the ratio of the field dry density
to the maximum dry density. The results of the test, performed in
accordancëwithA.S.T.M. Test Method D-.l556--64, are as follows:
Sample . :Field Dry Field Moisture Relative. .. Location Density (gm/cc). Content (%) Density (%)
T-1 @.11 It 1.674 11.1 90 5
(3) A Direct Shear Test was performed on the proposed foundation
soils at 90% of the maximum dry density and optimum moisture .content.
The sample was returned to the lab and remolded to its respective
conditions. . The results of the test performed in general accordance
with accepted engineering practice, are as follows: S
Condition Angle of Apparent .... Sample Location Density (gm/cc) Internal Friction Cohesion C (psf)
• T-l@ l. ft. . 1.674 32 370
S 90% of Maximum . S
Dry Density S S
RECOMMENDATIONS .
S
• •
H Grading: .
Grading should be performed in accordance with the attached
S "Recommended Grading Specifications General Provisions".
Expansive or loose soils were not encountered' during our (
S reconnaissance, so no special provisions to properly grade
the site are anticipated. - '
SDE 1774 October 11, 1979 Page Four
Footings
The prevailing foundation soils on the building site are not
detrimentally expansive and conventional isolated or continuous
spread footings should be adequate to support the proposed
. .' •' '• strUcture. Footings should. be founded a minimum of 12 'and 18
inches below lowest adjacent grade for single and, two story
structures, respectively. Minimum footing widths should be
12 and 15 inches respectively Footings crossing the transition
zone between cut and fill are to be reinforced with 1 #4 bar
p1aced.3'inchs clear of the bottom of the. footing and'l #4
bar p1acéd1 inches. below the finish slab elevation. 'The
:,'. .. steel is to extend ten feet each side of the transition line'.
Structures that will not tolerate differential settlements (foundations,
concrete. decks, swimming pools, walls, etc.) should' not be located
within .5 feet of :the top edge of a slope. ' Foundations. located out-
side the .5 feet slope setback should be extended in depth such that
the bottoin.outside edge of the footing is a minimum horizontal
'
distance'of .5 feet from the slope face. .. • • : .. •
The allowable bearing capacity of 3500 psf may be used for footings '.
a minimum of:12'inches wide and 12 inches in depth inthe'natural'
soils and in properly compacted fill.
. • •
Drainage 'provisions should be incorporat6d ,into the site 'develop-
ment to prevent runoff from gaining access to the fill slopes and
increasing the probability of accelerated erosion. Runoff from
impervious surfaces, (i.e.-driveways, sidewalks, roofs, patios,
'etc.') should'not be allowed to concentrate or run over the top of
the fill slopes. Preferable plants for the constructed banks 'are
lightweight, "native" types with minimal irrigation requirements.
Page Five
The recommendations of this report pertain only to the site in-
vestigated and are based upon the assumption that the soil conditions
do not deviate from those disclosed in the borings If any variations
or undesirable conditions are encountered during construction, or
if the proposed construction will differ from that planned at the
present time, San Dieguito Engineering Incorporated, should be
notified so that supplemental recommendations can be given
This report is issued with the understanding that it is the re-
sponsibility of the owner, or of his representative, to ensure
that the information and recommendations contained herein are brought
to the attention of the architect and engineer for the project and
incorporated into the plans, and that the necessary steps are taken
to see that the contractor and subcontractors carry out such re-
commendations in the field
The. findings of this report are valid as of the present date.* How-.;
ever, changes in the conditions of a property can occur with the
passage of. time, whether they be due to natural processes or the
works of man on this or adjacent properties. In addition, changes.
• inapplicable or appropriate standards may occur, whether they
result-from legislation or the broadening of knowledge. Accordingly,
the findings of this report may be invalidated wholly or partially
by changes outside our control. Therefore, this report is subject
to review and should not be relied upon after a period of three years..
Buff to Tan Slightly Silty
Fine to Medium Sandstone (Dense)
Ff
5
5_
Bottom of Hole 2 feet.
3
C-
)1Th 1(?LI.
0R/N6 Alo T-1
Buff to Tan Slightly Silty
Fine to Medium Sandstone (Friable) -
5,.•
.4 t'
Buff to Tan Slightly Silty
-Ik Fine to Medium Sandstone (Dense)
-
\iS
•
- .•
S •.••
Bottom-of Hole 3 feet.
NO. T-2
p-r 2
5DE 1774
1C0ARSEGRAINED:. more than 50%
of the material is larger than
the No. 200 sieve size.
GRAVELS CLEAN GRAVELS OW 'More than 50 of I coarse V V. .:fraction is larger than No. 14
V sieve size but smaller .than 3"..
V
: OP
GRAVELS WITH FINES GM (appreciable amount of fines)
GC
SANDS.•
V
CLEAN SANDS . SW More than 50% of coarse
fraction is smaller than No. 4 SP sieve -size.'' V
V V V
V
V V SANDS WITH FINES SM V V
'(appreciable amount of fines) V
SC
FINED GRAINED: more than 50% V V of 'the material is smaller than
the No. 200 sieve size
..'SILTS AND CLAYS ML
Liquid Limit CL
V ;•
V
V
V
V' Less Than 50 V
V
V OL.
V V V
V V SILTS AND CLAYS MH
V
' Liquid Lbiit CH V V Greater than 50
OH
V V HIGHLY ORGANIC SOILS PT
V Well graded gravels, gravel-.
sand mixtures, little or no V
fines.
V . Poorly graded gravels,:gravel-
sand mixtures, little or no
fines. .•.. :
V'' Silty gravels,'pc;orly graded
gravel- sand-silt mixtures.
.Clayey gravels, poorly graded
gravel-sand-clay mixtures.
Well 'graded sand, gravelly V
V sands., little or no fines. V Poorly graded; sands,gravelly
V sands, little or no fines.
V Silty sands, poorly graded
V sand and silt mixtures. .' Clayey sands, poorly graded V
sand and clay mixtures.;
V Inorganic silts and very fine
V V V sands, rock flour, sandyVsilt :
or clayey-silt-sand mixtures
with slight plasticity. Inorganic, clays of low to.
medium plasticity,ggraveUy
V
' clays, sandy clays, silty clays,
lean clays.
V V Organic silts . and organic silty . clays of low plasticity. •
Inorganic silts,-micaceous or
V V diatomaceous fine sandy or.
V V
, silty soils, elastic silts.
V Inorganic clays of high plast-
icity,, fat Clays.
Organic clays of medium to
high plasticity.
Peat and other highly organic
V soils.
SAN DIEGUITO ENGINEERING, INC.
.
V SDE 1744
PLATE #3
SPECIFICATIONS - GENERAL PROVISIQ RECOMMENDED GRADING
GENERAL INTENT
The intent of these specifications is to establish procedures for
clearing, compacting natural ground, preparing areas to be filled
and placing and compacting fill soil to the lines and grades shown
on the accepted plans. The recommendations contained in the pre-
liminary soil.investigation report and the attached special pro-
visions are a part of the recommended grading specifications and
shall supersede the provisions contained hereinafter in the case: of
conflict'..
INSPECTION AND TESTING
A qualified soil engineer shall be employed to observe and test the
earthwork in accordance with these specifications. It will be nec-
essary that' the,soll engineer or his representative provide adequate
obsrvations so that he may provide a memorandum that the work was
or was not accomplished as specified. It shall-be -the responsibility
of the contractor to assist the soil engineer and to kee-b him ap-
' praised of work schedules, changes and new 'information and data o
that he may provide the memorandum to the owner and proper county
authorities,-as required.
if, in the opinion of the soil engineer, substandard conditions are
encountered., such as questionable soil, poor moisture control, in-
adequate compaction, adverse weather, etc., he will be empowered 'to
either' stop construction until the conditions are remedied or cor-
rected or recommend rejection, of the work.
L Soil tests used to determine the degree of compaction will be 'per-
formed in accordance with the following American Soceity for Test-
ing and 'IVIaterials test methods:
Maximum Dry Density, and Optimum Moisture Content
A S T M. D-1557-70
Density of Soil In-Place
A S T M. D-1556-64
PREPARATION OF AREAS TO RECEIVE FILL
All vegetation, brush and debris shall be removed, p
i
l
e
d
a
n
d
b
u
r
n
e
d
or otherwise disposed of After clearing, the natur
a
l
g
r
o
u
n
d
s
h
a
l
l
be scarified to a depth of 6 inches, brought to the proper mois-
ture content, compacted and tested for the minimum
d
e
n
s
i
t
y
s
p
e
c
i
f
-
ied in the special provisions or the recommendations c
o
n
t
a
i
n
e
d
i
n
the preliminary soil investigation report.
When the slope of the natural-ground receiving fill ex
c
e
e
d
s
2
0
016 (5 horizontal to lvertical), the original ground shall be
s
t
e
p
p
e
d
or benched as shown on the attached Plate A. Benches
s
h
a
l
l
b
e
c
u
t
to a firm competent soil condition The lower bench
s
h
a
1
1
b
e
a
t
least 10 feet wide and all other benches at least
6 feet wide Ground slopes flatter than 20% shall be benched when con
s
i
d
e
r
e
d
necessary by the soil engineer.
FILL MATERIAL:
Materials placed in the fill shall be approved by the s
o
i
l
e
n
g
i
n
e
e
r
and shall he free of vegetable matter and other delete
r
i
o
u
s
s
u
b
-
stances. Granular soil shall contain sufficient fine m
a
t
e
r
i
a
l
t
o
fill the voids. The definition and disposition of oversized rocks, expansive and/or detrimental soils are covered in the
s
p
e
c
i
a
l
.
r
o
-
visions. 'Expansive soils,,soils of poor graduation o
r
s
t
r
e
n
g
t
h
characteristics may be, thoroughly mixed with other soils to pro-
vide 'satisfactory fill material, but only with the e
x
p
l
i
c
i
t
c
o
n
s
e
n
t
of the soil engineer.
•
'
PLACING AND COMPACTION OF FILL
Approved material shall be placed in areas prepared to rec
e
i
v
e
fill in layers not to exceed six inches in compacted thi
c
k
n
e
s
s
Each layer shall have a uniforn moisture content in the ran
g
e
t
h
a
t
will allow the compaction effort to be efficiently applied
t
o
a
c
h
i
e
v
e
the specified degree Of compaction. Each layer shall b
e
u
n
i
f
o
r
m
l
y
compacted to ,a minimum specified density with adequately, sized equipmert, either specifically designed for soil compac
t
i
o
n
o
r
o
f
proven reliability. The minimum degree of compaction to
b
e
1
c
h
i
e
v
-
,
ed is specified in either the special provisions or the reco
m
m
e
n
d
-
ationscontained in the preliminary soil investigation re
p
o
r
t
.
'. Field tests and inspections to check the degree of compa
c
t
i
o
n
o
f
the fill will be taken by the soil engineer or his repre
s
e
n
t
a
t
i
v
e
The location and frequency of the tests shall be at the
s
o
i
l
e
n
g
i
n
-
eer's discretion. In general, the density tests will b
e
m
a
d
e
, at an interval not exceeding two feet in vertical rise and/or 500
c
u
b
i
c
yards of embankment.
SEASON LIMITS:
-
Fill'shall not beplaced during unfavorable weather cond
i
t
i
o
n
s
.
W
h
e
n
work is interrupted by heavy rain, filling operations shall
n
o
t
b
e
resumed until the proper moisture content and density of the
f
i
l
l
: has been achieved. Damage resulting from weather shal
l
b
e
r
e
p
a
i
r
e
d
before acceptance of work.
/
UNFORESEEN CONDITIONS:
In the event that conditions are encountered during the site
p
r
e
-
paration and construction that were not encountered dur
i
n
g
t
h
e
p
r
e
-
liminary soil investigation, San Dieguito Engineering, Inc, assum-es no responsibility for conditions encountered which di
f
f
e
r
f
r
o
m
those conditions found and described in the preliminary soil
i
n
v
e
s
t
-
igation report.
SPECIAL PROVISIONS
The minimum degree of compaction to be obtained
i
n
c
o
m
p
a
c
t
i
n
g
natural ground and in the compacted fill'shall'.be 90 percent
of the maximum dry density obtained in the laborato
r
y
,
A
S
T
.
M
.
D-1557-70
Detrimentally expansive soil is defined as soil w
h
i
c
h
w
i
l
l
s
w
e
l
l
: more than 3 percent of the original sample thickness. The exp
a
n
-
sion potential is determined by allowing the mate
r
i
a
l
,
r
e
m
o
l
d
e
d
t
o
90% of its maximum dry density, to swell against
a
s
u
r
c
h
a
r
g
e
o
f
150 psf when brought into contact with water. The e
x
p
a
n
s
i
o
n
o
f
t
h
e
'sample is -determine by measuring the swell from air-dry to satur-
ated conditions
$$
'Oversized fill material is -defined as rocks or -lumps over. six inches in diameter. At least 40 percent of the-fill
s
o
i
l
s
h
a
l
l
- $ pass through •a No.4 US. Standard Sieve..
,
SCHEMATIC ONLY
NOT TO SCALE
SAN DIEGUITO ENGR INC FLtTE A
c. •,#...
1200 ELM AVENUE .* TELEPHONE:
CARLSBAD, CALIFORNIA 92008 .
(714) 729-1181
Building Department
Qtitp of QCarIbab
'Y DES JUMENRALMG CATION
Permit No._____________________
Issue-,Date.
CERTIFIQTE OF COMPLIANCE WITh ENERGY COI. SEATION DESiQi REQUIRB"ENS
CONTAINED 11, ARTICLE 1, PART 6 TITLE 214, CJ-'LIFORNIA A111L CODE
1, Zrr,07A'f( Cot/,Yf , hereby certify that J am Familiar
with the state energy conservation sLaridards mandated An
CAC Title 24, Section T20-1401 through T20-1406, and that the
plans and..other.documents submitted in support of the ap'lication
for a building permit at o C =2~.: Z
Address • • . . •
Assessor's Parcel No. • • Dated
comply with all current requirements of these regulations.
Signature
Title c•
( Architect, Engineer, Contractor, Othei.) . . • •
State License or Certificate No. L.Jb_9' _•
Date JQT
'Submit to the Building Department with permit application. •
••
• • •
Form 78-101
'•' -,.:
LEUCADIA COUNTY WA111R. DISTRICT
APPLiCATION FOR SEWER SERVICE
'I
Ovine, s Name Jerry Collins
Mailing Address
Carlsbad, Calif 92008
Service Address:: 2620 Galaci a
Phone No. 753-2272
:;; rR.4Ir ISJD !JON
PERMiT.
Tract Description: lot 75 La Costa South 1
Assessor's Parcel No. ALU FOR BY
Type of Building No. Units -__1 Connection Fee 600. 00
Lateral Size: ..4.1' 6". 811 Saddle -. Easement Connection pre-pd
Extra Footage: @ $.. Extra Depth: @ $ .
Lateral Fe
Amount Rc'd $L Prorated Sewer - Ck. No/Cash i-Q . .
r'.a Le .;.. -iZ-"- service Fee 1./ S
By Total Rec'd
The an plicatioi nost be signed by ne owni (or his Q)thor1Led eprecent( i ivc Cl
the property to be served. The total charges must be paid to the District at. the
time the application is submitted. .• S.
If a service lateral is: required, it will be installed by the Leucadia County Water
District. The service lateral is that part of the sewer system that extends froi
the main collection line in the street (or easement) to the point in the street (at
or near the applicant's property line) where the service lateral is connected to
the applicant's' bull ding sewer. The applicant is res ponsible for the constru.ct cii
at the applicant's expense, of the sewer pipeline (building sewer) frori-i the appi i
cant's plumbing to the point in the street (or eament) where a connection S. ii-lade
to the service lateraL . . . •• .• ••. S.
The connection of the applicant's building sewer to the service lateral shaM be
made by the applicant at his expenses The connection mus,t be made in confoniit.y
with the District's specifications, rules and regulations; and IT I"UST BE. INSNC ED
AND APPROVED BY 111F. DISrfW,( BIWU THE SWR SYSIFfl MAY BE USED BY THE A,Pi
THE APPLICANT,01IR ifi S AUI UOR (/( 1) R1 PRFSHI u\t VE MUST NOTIFY THE DISTRICT AT IHE
TIME INSPECTION IS DESIRED. ANY CONNECT.(UN i"L'\UI TO THE SERViCE LATERAL 0i (Ot L'i
TION LINE WITHOUT PRIOR APPROVAL AND INSPECTION BY THE D'ISTRrCT WILL BE CONSIDERED
INVALID AND WILL NOT BE ACKNOWLEDGED. • • •. • . .
The prorated sewer service fee is based upon the date the District estirates that
service will begin and covers the balance of the fiscal year.. There will be no
additional fee or refund if service actual I' coriences on a different date. For
succeeding fiscal years, the sewer service. fee will be collected on the tax roll
in the same manner, as property taxes. •
S • (fl fl\L\ H i\ n
The undersigned
•
hereby agrees that i Yen Of ' tnd
to the conditions as stated LIrt,Th\iuL
,/Th1
S 3UII.DNC, PM1 NO. I E1~L'7 -/ __.
___
• S
C' • 046r 's Siortature !Qo-?J1&te
S • L DATE AUTHORIZED SIGNATURE S.
.1.