Loading...
HomeMy WebLinkAbout2607 ACUNA CT; ; 87-149; Permit- .. DECLARATIONS LENDER WORKER'SCOMPENSATION I OWNERiBUILDER " CONTRACTOR ., :. , .., .". ....~ 1131 t I Whlte ~ Inspector Green ~ (1) Finance Yellow - Assessor Plnk - Appllcanl Gold ~Ternporary File ARLSB 3R REF Darnel 1 87-1 49 REQUEST F( CITY OF C Account No. see #AD 2607 Acuna Court :UND Vendor No. Amount of Refund 8 10,057.73 Fee paid F~~: Buildinq Permit 87-149 (attached) Date Fee Paid: 10/27/87 Fee Paid By:. Elston H Palmer Fac s Su orti g R quest: Refund requested on expired permit. Building permit fee is not refundagye 6 t Ylcense ax n Bridge 360-8YO-OO-OO-87iO -~5d30,'~:Fan3~28_810-gO~egg-a8r8e35 ~13g7b~tL$21Px d0?%?6~80-00-8162 - $8547.73, FMF 880-519-93-06-0000 ,$310. Owns could not arrange financing for home. r'dg P Signature of Applicant: " I , IDeDt. Jafication: i I 0 Disapprove Date Finance Investigation: Rec: 0 Approve 0 Disapprove Dept. Head Signature Date City Manager's Action: 0 Approve 0 Disapprove City Manager Signature Date DEVELOPMENTAL SERVICES 2075 LAS PALHAS DRIVE CAALSBAD, CALIFORNIA 92008-1989 BUILDING DEPARTMENT TELEPHGNE (619) 438-1161 Date: Aug. 26,1987 To : Louis Holston PC;\ 87-149 Dated March 23, 1987 2186 San Dieguito Dr. Del Mar, CA 92014 Subject: Plan Check Expiration Our records indicate that you have not obtained your building permit for which you filed an application on the date shown above. The provisions of Section 304(c) of the Uniform Building Code state: Sec. 304(c) Expiration of Plan Check. Applications for which no permit is issued within 180 days following the date of application shall expire by limitation and plans submitted for checking may thereafter be returned to the applicant or destroyed by the Building Official. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon mitten request by the applicant showing that circumstances beyond the control of the applicant have prevented action from being taken. In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan check fee. For your convenience, please check the appropriate box below indicating your intentions and return this Letter to the address above. - Project abandoned. I will pick up plans in 10 days. Sigmtzre 3at i Project abandoned, plans may be destroyed. Signature Date X Xaximun L80-day time extension requested for the following reason: SUISNESS TRAVEL & COMMITMENTS HAVE PREVENTEJ THE OWNER FROM FINALIZING THE FINANCING OF THIS PROJECT. Signatur Date 8-29-87 If you have any questions, please contact the Carlsbad Building Departxent at LEWIS PYHOLSTON ARCHITECT 139-1161. DEVELOPMENTAL SERVICES BUILDING DEPARTMENT 2075 LAS PALMAS DRIVE CARLSBAD, CALIFORNIA 92008-1989 (619) 438-1161 Louis Holston 2186 San Dieguito Dr. Del Mar, CA 92014 Re: Plan Check Extension 87-149 In answer to your request of August 26, 1987 , an extension of 180 days has been granted to March 23, 1988 Section 304(c) of the 1979 Uniform Building Code prohibits any further extension of time. Director Building and Planning MO : ky ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92 123 (619) 560-1468 APPLICANT FILE COPY nups ODESIGNER The plans transmitted herewith have been corrected where building codes. with the jurisdiction's building codes when minor deficien- The plans transmitted herewith will substantially comply cies identified SEE R&t4AR6 =.LOA aye resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies and resubmitted for a complete recheck. The check list transmitted herewith is for your information. plans are submitted for recheck. The applicant's copy of the check list is enclosed for the 0 necessary and substantially comply with the .jurisdiction's 0 identified on the enclosed check list and should be corrected 0 The plans are being held at Esgil Corp. until corrected 0 jurisdiction to return to the applicant contact person. 0 The applicant's copy of the check list has been sent to: 0 Esgil staff did not advise the applicant contact person that m Esgil staff did advise applicant that the plan check has been completed. Person contacted: EL~TO~ ?AALML?R Date contacted: IO -5 -87 Telephone # 72/-414e RE MARKS:^ ?&IVIDE. FA.d FOfi LA.Uh,DRY PaA Id F/c.<T plan check has been completed. BY: 5YED AGEM Enclosures: ESGIL CORPORATION 9-25-87 183. 187. + 1. 1. CITY OF CARLSBAD ilg PLAN CHECK NO. 87-274 111 AUGUST 18, 1987 REMAINING ITEMS TO BE RESOLVED BY THE CITY on the exterior of the building is unacceptable unless ed by the city. Provide a letter from the soils engineerconfirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soil report are properly incorporated into the plans. (When required by the soil A. The building official waste and PLUMBING imum 4" drain for 1/8" per foot slope and the building piping less than 1/4" per 12" slope. If you have any questions, please cantact Manuel Ainza of Esgil Corpora ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO. CA 92 123 (619) 5601468 DATE : ' /IfPIL ,2 9. f?!?? . JURISDICTION: &Tf bf &RLS./3A-;D - PLAN CH PLAN CHECK NO: 87- /4 7 URISDICTI DFILE COPY ODESIGNER OUPS PROJECT ADDRESS: DATE : ' /IfPIL ,2 9. f?!?? . JURISDICTION: d/Tf bf &RLS./3A-;D nFT1.G COPY PROJECT NAME: 5F-R 0 necessary and substantially comply with the .jurisdiction's The plans transmitted herewith have been corrected where building codes. The plans transmitted herewith will substantially comply 0 with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies and resubmitted for a complete recheck. The check list transmitted herewith is for your information. plans are submitted for recheck. The applicant's copy of the check list is enclosed for the identified on the enclosed check list and should be corrected ,@ The plans are being held at Esgil Corp. until corrected 0 jurisdiction to return to the applicant contact person. fl The applicant's copy of the check list has been sent to: Ew~od PA LM@? /z4c kG5 WJG /%LU3RBDI(, a 92); b 0 Esgil staff did not advise the applicant contact person that plan check has been completed. @ Esgil staff did advise applicant that the 1 check has been completed. Person contacted: EL25PhP %Lfi'C/i Date contacted: 4- 7g -(7 Telephone # IU - 4-144 LCP '/ZE?- (.l?CIJ-. REMARKS : - /- BY: 5'tC.D 11 [ L'Efi,j Enclosures: ESGIL CORPORATION Citp of &arI$bab ~~~ PLAN CORRECTION SHEET Plan: Check No. 8 7-/49 Date plans received by the jurisdiction Date plans received by plan checker e/ ?L) c 3 Date initial plan check completed 4/24/& BY ~YB> AL.C+I FOREWORD: PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. modification or change. All circled items have The items circled below need clarification, to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303 (c), of the Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A- - PLANS 1. Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, 2. To facilitate rechecking, please identify, next to each circled item, the sheet of the plans upon which each correction on thia sheet has been made and return this check sheet with the revised plans. . ._ . .. . ESGIL CORPORATION 9320 CHES,\I'EAKE DR.. SUITE 308 SAN DIEGO. CA 03 133 (6 1'3) 560% 1468 PROJECT NAME : < 0 0 0 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. with the jurisdiction's building codes when minor deficien- The plans transmitted herewith will substantially comply cies identified checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is the jurisdiction's Esgil Corp. until corrected plans are submitted for recheck. copy for your information. The plans are being held at The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list_has been sent to: ELS.TC)G f/lLMci: I 2 4 3 A tfcr LA A!l!? are resolved and FA LL f- p..cc:( 1: i 9;7oz& Esgil staff did not advise the applicant contact person that plan check has been completed. Esgil staff did advise applicant that the plan check ha been completed. Person contacted: CL47Z!Ai p~l /4(:L ~ t-6 Date contacted: Qlg\rg7 Telephone #221- L!;q$ 0,'728"c265 REMARKS : BY : .> .l'i D &, A c rq ENCL : ESGIL CORPORATION 3- 2 8-87 Date initial plan check completed: FOREWRD: PLUSEREAD Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws attenuation and access for the handicapped. regulating energy conservation, noise The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. 1982 U8C (eff. 7/1/85) 1985 UPC (eff. 11/12/86) 1984 NEC (eff. 10/1/85) 1985 UMC (eff. 11/12/86) The above regulations apply to residential construction. The circled items need clarification, modification or change. All items have to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303 (c). 1982 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To sDeed UD the recheck DrOCeSS. note on this been addressed i.e.. ~lan sheet. SDecification. list (or a CODV) where each correction item has when YOU submit the revised Dlans. etc. Be sure to enclose the marked UD list mn: ~~~~~~(~~rn~~~p~~~m~~~~~wwp~. Carlsbad List 10, Single Family Welling and Duplex With All Supplements 1 3/25/86 Q A. pIMs Please make all corrections on the original acings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: Esgil Corporation, 9320 Chesapeake Drive, Suite C208, San Diego, California 92123, (619) 560-1468. $ Please make all corrections on the original any original plan sets that may have been tracings and submit two new sets of prints, and returned to you by the jurisdiction, to: The jurisdiction's building department. ,d Indicate on the Title Sheet of the plans, the name of the legal owner and name of person responsible for the preparation of the plans. Section 302 (a) 7. / Plana, specifications and calculations shall be signed by a California state licensed engineer or architect. (California Business and Professions Code). ,d Specify on the Title Sheet of the plans the gross floor area of each element of this project and balcony. Section 302 (c). including dwelling, garage, carport, patio, deck Q Provide a statement on the Title Sheet of e plans that this project shall comply with Title 24 and 1982 UBC, UMC, and UPC and 1984 NEC . f: Submit fully dimensioned plot plan drawn to scale showing location, size, and use of all existing and proposed stauctures on the lot. Identify property lines and show lot dimensions and all easements. Show location of all cut or fill slopes and approximate finish floor elevations for all stmctures and show elevations at all lot corners. Section 302 (e). ,d Indicate distance from center line of street or alley to property line and distance from property lines to proposed building. Section 302 (c). B. FlREm(Xl # walls closer than 3 feet to property lines shall be one-hour rated construction, have no openings, and shall have 30 inch parapets when the building floor area exceeds 1,000 square feet on any floor. (Table 5. A. Section 1709 (a)). ,d Projections, including eaves, may not extend more than 12 inches into the 3 foot setback from the property line. Eaves over required windows shall be not less than 30 inches from the side and rear property lines. Section 1710 and Section 504 (a) and (b). )d Plastic skylights shall not be installed within 8' of an exterior wall located where openings in such exterior wall are prohibited or required to be protected. Section 5207 (a) 7. ,Jd ProjeCtions, including eaves, &all be one-hour fire-resistive construction, heavy project into the 3' setback area from the timber or of noncombustible material if they property line. Section 1710. p! Show location of permanently wired smoke detector, centrally located in corridor leading to sleeping rooms or above stair if sleeping rooms are on upper level. Section 1210. ,Id. A smoke detector shall be installed in the basement of dwelling units having a staiway which opens from the basement into the dwelling. Such detector shall be connected to a sounding which will be audible in the sleeping area. device or other detector to provide an alarm Section 1210. 2 3/25/86 c. Rm( SIZES. LIm. VmInATIcM m CdAZIIG - p< Habitable rooms, other than kitchens, shall contain at least 70 square feet of floor area. Section 1207 (b). g) Window area must be at least 1/10 of the Section 1205 (a). Appears to be deficient in oor area and a minimum of 10 square feet per 0 Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet. In bathrooms, laundry rooms and minimum is 1.5 sq. ft. (Section 1205 (a)). similar rooms 1/20 of area is required and @ At least 112 of the coma wall must be open and have an opening not less than 25 sq. ft. if light and ventilation is being supplied from an adjacent room. Section 1205 (a). @ Required windows shall not open into a roofed porch unless the ceiling is at least 7 feet and the longer side is at least 65% open. Section 1205 (a). jd Provide mechanical ventilation capable of providing five air changes per hour in bathrooms. water closet compartments, laundry rooms and similar rooms if required openable windows are not provided. Section 1205 (a). ,& No habitable room, other than a kitchen, shall be less than 7'0" in any dimension. Section 1207 (c). $. Show that ceiling height for habitable rooms is a minimum of 7'6". Section 1207 (a). Q llways, corridors, and bathrooms is a min- Show ceiling height for laundry room, of 1'0". Section 1207 (a). / Dimension on the plans, the 30" clear width for water closet compartments and 24" clearance Section 511 (a). in front of water closet. @ Specify safety glazing for glazing in hazardous locations such as glass doors, glazing adiacent to such doors and glazing adjacent to @ Glazing, in the saw wall plane as a door, must be safety glazing if within 12" of the door and less than 60" above the walking surface, unless the glazing is leaded on faceted glass. Section 5406 (d) 7. Q tempered, laminated or approved plastic shower floor). Section 5406 (d) 5. (including windows within 5 feet of tub or Glazing in shower and tub enclosures shall ;ld: Sleeping rooms shall have a window or exterior door for emergency exit. Sill height shall not exceed 44" above the floor. The window must have an openable area of at least 20" and the minimum openable height 24". 5.7 square feet with the minimum openable width Section 1204. 7 A mezzanine is an intermediate floor and may not have a floor area exceeding 33 113 percent of the total floor area in the room below. "he mezzanine floor must have a clear height of 7 feet, above and below, and must have the long side open to the room below except for posts and protective walls or railings not exceeding 42" in height. Section 1716. ,& The loft you show does not comply as a mezzanine floor and is, by Uniform Building Code definition, a story. Section 1716. 3 3/25/06 D. $. Floors above the second story shall have not less than 2 exits. Section 3303 (a). tii Required exit dooways shall be not less 36" in width and not less than 6'8" in height, and shall be capable of opening at least 90 degrees. Section 3304 (e). - @ Provide 36" high protective railing for porches, balconies, and open sides of stair landings. openings between railings shall be less than 6". Section 1711. Q 0 ection 3306 (b) 6 (c). Show how guardrail connection details are equate to support 20 pounds per lineal foot at a right angle to the top rail. Table 23-B. Provide stairway and landing details. @ Maximum rise 8" and minimum run is @ Minimum headroom is 6'6". @ Minimum width is 30". 9". @ 11 handrails per Section 3306 (j), shall satisfy the following: @ Provide handrail for stairways with 4 @ Handrail shall be 30" to 34" above the @ The handgrip portion of handrail shall be not less than 1 114" nor more than 2" in cross-sectional dimansion. (See attached). or mre risers. nosing of treads. r/ Every stairway landing shall have a diaension, measured in the direction of travel, at least equal to the stairway width. Section 3306 (8). )6. A door may open over a stairway landing provided the door, in any position, does not reduce the clear area of the landing in the one-half the required width of the stairway. direction of stairway travel, to less than Section 3306 (g). fl A door may open inward at the top step of a stairvay provided the top step is not more than 7 112" lower than the floor level. Section 3304 (h). Provide details of winding stairway complying with Section 3306 (d): & Minimum tread is 6 inches at any point and minimum 9 inches at a point 12 inches from where the treads are narrowest. # ~aximau rise is 8 inches. y' Minirrmm width is 30 inches. # Provide spiral stairway details, per Section 3306 (f): /B? Minimum run is 7 112 inches measured at a point 12 inches from where the treads are the narrowest. ,X. Maxh rise is 9 112 inches. d Minimum headroom is 6 feet 6 inches. Spiral stairways may not be used for required exits when the area served is greater than k00 sq. ft. Section 3306 (f). 4 3125186 #. spiral stairways must have a clear walking space of 26 inches between the column and handrail, show d-ion. Section 3306 (f). 6 Provide I.C.B.O. Research Report and Number for metal stairway, or submit plans and with the building department or note that the calculations and approved fabricator registered stairway fabrication shall be done under special Section 306 (a) 4B and Section 306 (E). inspection per the approved fabrication plans. H. In buildings over 2 stories in height, provide 314 hour fire-rated assemblies for all openings in the exterior wall below or within 10 feet horizontally of an exterior stairway. An exit balcony with 2 separated stairways is exempt. Section 3306 (1). / Exterior stairways shall not project into the 3 foot setback from the property lines. Section 3306 (n). @ Iha walls and soffits of the'enclosed usable space under interior stairs shall be protected on the enclosed side as required for one-hour fire-resistive construction. Section 3306 (m). ,d The maximum slope for a fire retardant built-up roof, with rock or gravel surfacing, is 3 inches in 12 inches, Section 3203 (e) 2. Q @ ilt-up roof, with cap sheet surfacing, is 112 The minimum slope for a fire retardant inch in 12 inches. Section 3203 (e) 3. Specify minimum 114 inch per foot roof s ope for drainage or design to support accumulated water. Section 3207 (a), Section 2305 (f) and Section 2511 (d) 6. r. Show roof drains and overflows. Section 3207. @ Provide skylight details to show compliance w~th Sections 3401 and 5207 or provide I.C.B.O. approval number. @ Plastic skylight must be separated from each other by at least 4 feet. Section 5207 (a) 6. fl Show attic ventilation. Minh vent area at least 50% of the required vent is at least 3 is 11150 of attic area or 11300 of attic area if feet above eave vents or cornice vents. Show required area and area provided. Section 3205 (c). @ Specify roof slope. 1. )d Roof slope is not adequate for roof type specified. Table 32-B; Section 3203 (h). @ Specify roof I.bd.l and application. pter 32. ry: Specify I.C.B.O. or U.L. approval mmber for roof materials not covered in U.B.C., e.&, title, etc., Section 107. 7 Provide fireplace construction details or note construction to be per attached fireplace standard drawing. Chapter 37. pd Show veneer support and connections in Seismic Zones 3 and 4, comply with Section 3002, 4, 5, 6, and Section 2515 (a) regarding ties and #9 wire in horizontal joints or show construction to be per attached sheets 30-1 or 30-2. 5 3/25/06 fl. Show height and construction details of all rrmbonry walls. Chapter 24. 9 Note that cleanout openings shall be ovided at the bottom of all cells to be grout filled over 4' in a single pour. Cleanout shall be sealed before grouting, after inspection. Section 2414 (a) 8. @ Show floor and roof connections to rmsonry walls. Connection shall resist 200 pounds per lineal foot or the actual design load, whichever is greater. Cross grain tension or bending in wood ledgers is not permitted. Section 2312 (j) 3. A. 5) 9 Show a minimum 2" air space and flashing 9 Rovide details for damp proofing the useable space exists on the interior side of the walls. Section 1707 (d) . oundation walls, below finish grade, where Section 2516 (c) 7. I 0.fiW etween planter and building walls. 6. GAiLGEmm Garage requires one-hour fire protection on e garage side of walls and ceiling c0PIIK)n to the dwelling. Table 5. B. Section 503 (d). @A ULJPA fJLl 5&PARA770d p-/ ~11 elements supporting floor above garage, including walls supporting floor joists, to have one-hour fire-resistive protection on the garage side. Section 503 (a). 9 Show 1 3/8" solid core self-closing door Section 503 (d). ma DCC UPAKY SE~PDWO~I. or openings between garage and dwelling. 46. Garages are not permitted to open into a room used for sleeping purposes. Section 1108. 3. Openings between carport and residence windows. Section 1214. require self-closing doors and stationary over garage opening, lateral cross bracing at 71. Show garage framing section, size of header plate line, method of bracing garage front, and holddowns if required. Chapter 23. NOTZ: Hawimum shear panel ratio of height to width is 3 112 to 1. Table 25-1. pL Doors may open into the garage only if the floor or landing in the garage is not more than 1/2" lower than the door threshold. Section 3304 (h). 7. Provide an 18" raised platform for any FAU, water heater, or other device in the garage, which may generate a flame or spark, UMC Section 508, UPC Section 1310 (a). E. FaumATIOn @ per soils rel(ort, note on the plan the soils classification, whether or not the soil is expansive, and note the allowable bearing value. Section 2905 (c). A Ihe foundation plan does not comply with the soil report reconmendation for this project. Please review the report and modify design, notes and details as required to show compliance. @ Rovide notes on the foundation plan foundations, slab and building pad preparation. listing the soils report reconnwndations for 6 3/25/86 @ The soils report recomends excavations be reviewed by soils engineer. Note on the foundation plan that "Prior to the Contractor requesting a Building Department Foundation InsDection, the soils enaineer shall advise the building 0 0 - official in writing tbat: the building pad was prepared in accordance with the soils report; properly backfilled and compacted, the utility trenches have been and; the foundation excavations, formings and reinforcements comply with the soils report and approved plan". 9. %ow height of all foundation walls. Chapter 23. 7. Show height of retained earth on all foundation walls. Chapter 23. 9 o foundation to edge of cut or fill slopes and If cut or fill slopes exist, show distance show steepness and heights of cuts and fills. Chapter 29. ,Bd Note on plans that wood shall be 6" minimum above finish grade. Section 2516 (c) 7. @ Note on plans that surface water will drain away from building and show draw pattern and key elevations. Section 2905 (f). Dimension foundation per U.B.C. Table 29A: - Floors Sumorted* Stemwall 1 6" 2 12" 8" 12" 3 10" 15" 18" 18" 24" qoundations may support a roof in addition to the floors. Where only a roof is supported, use foundation for one floor. pd Show foundation sills to be pressure treated, or equal. Section 2516 (c) 3. a/ Show foundation bolt size and spacing. Section 2907 (e). $. Specify size, I.C.B.O. number and mufacturer of power driven pins. Show edge and end distance and spacing. Section 306 (f). 8/ If required by swctural calculations, anchors on foundation plan. Section 2312 (f). show size, imbedment and location of hold down @ If hold do- are required by calculations, note on plan that hold down anchors must be tied in place prior to foundation inspection. Section 305 (e) 2. Show adequate footings under all king walls and shear walls. Section 2907 (b). d Show on the elevations, stepped footings for slopes steeper than 1:lO. Section 2907 (c). p'. Show minimrrm 18" clearance from grade to bottom of floor joists and minimum 12" clearance to bottom of girders. Section 2516 (c). / Show pier size, spacing and depth into undisturbed soil. Table 29-A. @ Show minimum underfloor access of 18" x @ Show minimum underfloor ventilation equal 24". Section 2516 (c). to 1 sq. ft. for each 150 sq. it. of underfloor area. Openings shall be as close to corners as practicable and shall provide cross ventilation on at least two approximately opposite sides. Section 2516 (c). N. Specify that posts embedded in concrete shall be pressure treated per UBC Std. No. 25- 12. Section 2516 (c). I. $ Show wall bracing. Every exterior wood stud wall and main cross partition shall be braced at each end at least every 25 feet of length with 1 x 4 diagonal let-in braces or equivalent. Section 2517 (g) 3. &'. Note cross bridging or blocking. Floor joists and rafters 12" or more in depth shall be supported laterally by bridging at intervals not exceeding 8 feet, unless both edges are held in line. Sec. 2506 (g). pd: Show blocking at ends and at supports of floor joists, and for rafters at exterior walls. Section 2517 (d) 3. Show solid blocking at ridge line and at exterior walls on trussed roofs. Section 2506 (g), Section 2517 (h). Show double joists. Floor joists shall be &;led under bearing partitions running parallel with the joists. Section 2517 (d) 5. l,!d Bearing partitions, perpendicular to joists, shall not be offset from supporting girders, beams, walls or partitions, more than the depth of the joist. Section 2517 (d) 5. pf how rafter ties. Rafter ties shall be spaced not more than 4 feet on center and be just above the ceiling joists, where rafters and ceiling joists are not parallel. Section 2517 (h) 4. t"f. Show rafter purlin braces to be not less than 45 degrees to the horizontal. Section 2517 (h) 5. Jd. Show 1/2" minh clearance between top plate of interior partitions and bottom chord of designed). trusses. (To ensure loading will be as #. Show double top plate with minimum 48" lap splice. Section 2517 (g) 2. @. Show nailing will be in compliance with Table 25-Q. @ Show or note fire stops at the following locations per Section 2516 (f): in concealed spaces of stud walls and partitions, including furred spaces, at the ceiling and floor levels and at the wall. 10 foot intervals along the length of at all interconnections between concealed vertical end horizontal spaces such as occur at soffits, drop ceilings and cove ceilings; stringers at the top and bottom of the in concealed spaces between stair run and between studs along and in line with the run of stairs if the walls under the stairs are unfinished; and ducts, chimneys, fireplaces and in openings around vents, pipes, similar openings which afford a passage for fire at ceiling and floor levels, with noncombustible materials. p6. Show stud size and spacing. Maximum allowable stud heights; Bearing wall: 2 x 4 and x 6 max. 20'. Table 25-R-3. 2 x 6 max. 10'; Non-bearing: 2 x 4 max. 14', 2 J.86 Studs supporting two floors, a roof and Table 25-R-3. ceiling must be 3 x 4 or 2 x 6 at 16" O.C. 8 3/25/86 for glued laminated wood members shall be given pd Note an A.I.T.C. certificate of CompliMce Section 306 (f). to the building inspector prior to erection. ,J,d Detail all post to beam and post to footing connections and reference the detail to the plan. Section 2516 (m). pd Detail shear transfer connections, including roof and floor diaphragus, to shear walls. Section 2513. 9 ear walls, floor and roof diaphragus. Specify nail size and spacing for all Indicate required blocking. Maintain maximrtm and Section 4713 (d). diaphragm dimension ratios. (Tables 25 I, J, K) 9. show 3" x 4" or 2" x 6" studs in first story of three story building. Table 25-R-3. 9 Provide truss details and truss ca culations for this project. # Provide roof framing plan and floor framing plan. Section 302 (a) 7. ,p-f Provide framing sections through Section 320 (a) 7. @ Specify all header sizes for opening over 4 wide. Section 2517 (g) 5. @ Provide calculations for main vertical and horizontal framing members and post footings. Section 302 (a) 7. 9 Provide calculations for lateral loads, ear panels, shenr transfer and related. Section 302 (9) 7. @ show on the plans a11 structural calculations. requirements developed in the structural J& collrmns and posts located on concrete or masonry floors or decks exposed to the weather or to water splash or in basements and which support permanent structures shall be supported by concrete piers or metal pedestals projecting above floors unless approved wood of natural resistance to decay or treated wood is used. Section 2516 (c) 4. # Individual concrete or masonry piers shall project at least 8 inches above exposed ground unless the collmms or posts which they support are of approved wood of natural resistance to decay or treated wood is used. Section 2516 (c) 4. p. Show location of attic access with minimrtm size 22" x 30". Section 3205. @. Show draft separation for attic areas between units in a duplex. Section 2516 (f). /. Wood stud bearing walls, with studs at 24" o.c., require 3 ea. 2 x 4 or 2 ea. 2 x 6 or 2 ea. 3 x 4 top plates if supporting either floor members or roof tmsses that are spaced mare than 16" O.C. and do not bear within 5" of the supporting stud. Section 2517 (9) 2. Specify plywood grade and panel 9 i entification index. Table 25-N. p. when roof pitch is less than 3:12, design ridge as a beam. Section 2517 (h). pd If foundation cripple wall studs are less than 14" framing shall be solid blocking. Section 2517 (9) 4. 9 3125186 M. Cripple wall studs exceeding 4 feet in height shall be 3 inch by 4 inch or 2 inches by 6 inches when Supporting 2 stories. Section 2517 (g) 4. M. Show plywood sheathing over exposed eaves, or other weather exposed areas, is exterior grade. Section 2516 (8) 3. 9 Show a weep screed at the foundation plate 1 ne on all exterior and stud walls to be stuccoed. Section 4706 (e). @. Show corridor width to be minimum 36". Section 3305 (a). p. Specify truss layout for 30" x 30" attic access. +. Ridges, hips, and valleys shall be at Section 2517 (h) 3. least one size larger than supported rafters. 9 In open beam constmction, provide strap t es across the boama at the ridge support. Section 2501 (b). J. "ICAL All heating, ventilating, and cooling systems and appliances shall comply with the Uniform Mechanical Code. @ Show the size, location and type of all heating and cooling appliances or systems. @ =ow source of combustion air to furnace, per Chapter 6, UMC. M. Every dwelling unit shall be provided with heating facilities capable of maintaining a room temperature of 70 degrees F. at 3 feet above the floor in all habitable rooms. Show basis for compliance. UBC, Section 1211. pd Show minimum 30" deep unobstructed working space in front of furnace. Section 505, UMC. @ Note on plans, clearances to be per manufacturer's listing. Section 504, UMC. pd Furnace shall not be installed under any stairway. Section 704, UMC. pd Furnace shall not be installed in any bedroom, bathroom or in a closet or confined space with access only through such room, unless specified as direct vent appliance, enclosed furnace or electric heating appliance. Section 704, UMC. P Show I.C.B.O. approval number for prefab Ireplace. vrcf Show access to the attic or underfloor furnace to be minimum 30 inches by 30 inches. Section 708 h 709 UMC. Note that passageway to the attic furnace shall be unobstructed and have continuous solid flooring not less than 24 inches wide. Section 708, UMC. ,gd Show permanent electrical outlet and lighting fixture controlled by a switch for the attic furnace. Section 708, UMC. w. Show details to comply with Section 709 for furnace under the floor, or Section 710 for roof or outside furnace. @ Note on plan: Gas vents and noncombustible piping passing through three floors or less shall be effectively draft UBC, Section 1706 (a) 6. stopped at each floor or ceiling. 10 3/25/86 I. IILECIRIW (WIICUU aasl All wiring shall comply with the National Electrical Code. 9 8 e ectrical service, the location of the service Show on the plan the amperage of the panel and the location of any sub-panels. r ceptacles. pf. Electrical receptacle locations and/or spacing is not adequate in Show location of all electrical outlets for laundry, etc., outdoors, in Show at least one convenience outlet other garages and basemants. NEC. Art. 210-52. Q ou doors, and in garages and basements (other than for laundry and similar equipment) shall be GFI protected, NEC, M. 210-8. @ Note electrical system ground to be provided per NEC, Art. 250-81. Note convenience outlets in bathrooms, 1. -(nmRIRlr"l I @ Show water heater size, type and location 0 plans. WC, Section 1310. ,d Show source for providing comhstion air to fuel burning water heater. If wall opening in an enclosure are used, at least one-half of upper twelve inches of the enclosure and the required opening area shall extend into the UPC. Section 1307. one-half within the lower twelve inches. @. Fuel combustion water heater shall not be installed in bath or bedroom or in a closet UPC, Section 1309. opening into bath or bedroom. heater from vehicle damage. UPC, Section 1310. #. Provide adequate barrier to protect water 9 Show T and P Valve on water heater and @ 9 Note on the plan that hose bibbs and lawn ow route of discharge line to exterior. UPC, Section 1007 (e). C, Section 1903. Provide dryer vent to outside. s rinkler systems shall have approved backflow prevention devices. UPC, Section 1003. J.45. Shower stall shall accomwdate a 30" circle and have a minimum floor area of 1,024 sq. in. UPC, 909 (a). a. msll msoLArIlm rarpLlws1 p. Show details of duplex comn (party) walls and floor/ceiling assemblies to achieve a Sound Transmission Class (STC) rating in walls of 50 decibles and on Impact Insulation Class (IIC) rating on floor/ceiling of 50 decibles. Title 25. pf. Show how penetrations of assemblies for piping, electrical devices, recessed cabinets, bathtubs, soffits, or heating ventilating, or exhaust ducts shall be sealed, lined, or insulated to maintain required sound transmission rating. Title 25. pf Provide insulation in walls and ceiling to achieve STC of 50 between garage and living mea Title 25. if garage use is not controlled by resident. ~~ 11 3/25/86 State regulations (California Admin. Code) require that the design satisy one of the attached alternative energy padrages or submit mandatory conservation items be satisfied. calculations. The law also requires that many @, mow on the Title Sheet of the plans, the package that was selected, and next to each requlred elements of the alternative energy el-t show how you are complying with each element. If calculations were used, provide similar data on the plans. @. zhe plan sheet showing the required elements of the selected energy package, and with that selected package, must be signed by listing the design elements showing compliance either the owner or a licensed Drofessional design professional muSt note hislher state i.e., architect, engineer or contractor. A license number. Section 1403 of Title 20. q Show on the plans the "R" value for the wa Is, floors, ceiling and related areas. on Glazing Schedule. pf. Show on the plan how shading requirements are satisfied. @ me plans are not in compliance with the energy conservation compliance package selected conformance as follows: or design calculations provided. Show on plans Show double glazing as per Energy Design, I @ Specify on the buildina Dlans all of the mandatory energy conservation requirements as listed on the enclosure titled, "Mandatory Fnernv Conservation ReQuirements". @ ,Show the size, type, make, model and locatlon of the space heating (or cooling) system and prrMtu :".,A * , .- 0. CARlSMD S.P.D. h KmPLm SWPLmmI fl Energy conservation design should be for Zone 7 . See attached energy packages. @ Floor drains must have auto-prime (city policy). Note exhaust fans cwot be ductless type @. New residential units must be pre-plmbed jacks must be installed" where the water heater or future solar water heating. Note "two roof is in the one story garage and directly below the most south facing roof (City OrdiMnce No. 8093). @ Note "two 314" copper pipes must be installed to the most convenient future solar panel location when the water heater is not in a one story garage and is not directly below the most south facing roof. (City Ordinance No. 8093). @ All piping for present or future solar 9 wa er heating must be insulated when in areas that are not heated or cooled by mechanical meanr (city policy). Incorporate the waterproofing details, on attached Policy 80-8, where interior living space occurs below grade at the monry wall(s). .. 9 o-tion required by the attached Developmental Services Sheet 102683. # All new residential buildings, including additions, require a soils report. Please Show on the Title Sheet on the plm, the submit two copies. Jar/ HMV~ timbr framing, minh 6" x 10" b- and minimupl 8" x 8" post, for the structural bsam and column supporting the fire abve, is acceptable if shown on the plaru. separation btween the garage and living area (city policy). @ Please aae additional correctioru, or remarks. on the following page. 2he City of Carlrbad has contracted with Bgil Corporation located at 9320 Cb.esapeake Drive, Suite '108, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan &e& for your project. If you have any questions regarding there plan check it-, please contact it agil Corporauon. you have MY quutioru please contact Carter Darnall at the City of regarding City Building permit procedures, Carlsbad, 2075 Laa Pelmas Or., Telepkme (619)458-1161 lhanlc you. Ene1osUrss: 1. 2. Datet4-7-g3 CITY OF CARLSBAD Prepared by1 5 YE D A[.L,E& VALUATION AND PLAN CHFCK FEE Bldg. Dept. 0 Esgil PLAN CHECK NO. 87- I47 BUILDING ADDRESS a.07 AUWI aok7- APPLICANT/CONTACT SLST~~ 1-2 L~ZR PHONE NO. 7221 -4 BUILDING OCCUPANCY TYPE OF CONSTRUCTION '1- CONTRACTOR PHONE ,? . "<> DESIGNER PHONE 9UILDING PORTION VALUE VALUATION BUILDING AREA MULTIPLIER I Air Conditionine I I I Commercial I@ I Residential I I@ I Res. or Corn. I Fire Sprinklers (@ I I I COHHENTS: . . ." 1 1 .- 22 >+ aJ PLANNING ZONE: qL TYPE OF PROJECT AND USE: 3 Fb SCHOOL DISTRICT: SAN DIEGUITO- ENCINITAS CARLSBAD SAN HARCOS >c SETBACKS: FRONT *a ,..&&5 SIDE Q*-G REAR DISCRETIONARY ACTIONS: REDEVELOPMENT PERMIT REQUIRED: i,i b. LANDSCAPE PLAN COMHENTS: ENVIRONMENTAL REQUIRED: A- VI COASTAL PERMIT REQUIRED: YES ADDITIONAL COMMENTS: . - - I' ENGINEERING LEGAL REQUIREMENTS LEGAL DESCRIPTION VERIFIED? APN CHECKED? EASEMENTS: a&, RIGHT-OF-WAY: EDU~S: d & ACWO U DRAINAGE : IMPROVEMENTS: IELD CHECK DATE h INITIALS: PERMITS REQUIRED GRADING COMPLETION CERTIFIED: FEES REQUIRED PARK-IN-LIEU QUADRANT: ,4$'$ , FEE PER UNIT: TOTAL FEE: P.F.F.: d/& TRAFFIC IMPACT FEE PER UNIT:- %670 TOTAL FEE: p670 s. FACILITIES MGMT. FEE: &A RIDGE & THOROUGHFARE FEE: ~sP 1 - SEWER FEE (CONNECTIDN):~~~J~ SEWER LATERAL: h%'O Y aJ r .. .- < + m U 'E ADDITIONAL COMMENTS:- - 21. Eb 2 .E n E me - n 2s 0 aJ ,- v + m 2 OK TO ISSUE: DATE: u aJ DPDZ:DPD6:10/24/86 ENGINEERING CHECKLIST Date : 3-Z-q-87 Plan Check No. R7-/$49 Project Address: 26 OR Project Name: Bz&5zf%~ Field Check Date: 3 k 87 LEGEND 0' Item Complete 0 Your Action Item Incomplete - Needs 1.2.3 Number in circle indicates deficiency was identified plancheck number that LEGAL REQUIREMENTS Site Plan 1. Provide a fully dimensioned site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improve- ments, right-of-way width and dimensioned setbacks. 2. Show on Site Plan: Finish floor elevations, elevations of finish grade adjacent to building, existing topographical lines, existin driveway and percent (%) grade an 3. Provide legal description of property. 4. Provide assessor's parcel number. PERMITS REQUIRED Grading 5. Grading permit required. 6. Grading plans in plan check PE 7. Need the following completed prior to building permit issuance: A. Grading plans signed. B. Grading permit issued. C. Grading completed. D. Certification letter and compaction reports submitted. E. Grading inspected and permit signed off by City inspector. ired for work in public right-of-way sidewalk, connection to water main,etc). 9. Industrial Waste Permit application required. To be filled out completely and returned to Development Processing. FEES REQUIRED 10. Park-in-Lieu fees required. Quadrant: - , Fee Per Unit: , Total Fee: " . on nu on @do 11. Traffic impact fee required. Fee Per Unit: p670 , Total Fee: #670 . 12. Bridge and Thoroughfare fee required. Fee Per Unit: #5373 , Total Fee: k530 . 13. Public facilities fee required. 14. Facilities management fee required. Fee: dkflkfl 15. Additional EDU's required: @ ,. Sewer connection fee: LC~JO d'0 d 16. Sewer lateral required: W! check, please call the Development Processing Department at 438-1161. If you have any questions about any of the above items identified on this plan DEVELOPMENTAL SERVICES BUILDING DEPARTMENT 2075 LAS PALMAS DRIVE CARLSBAD, CALIFORNIA 92008-1985 Date: Aug. 26,1987 To : Louis Holston 2186 San Dieguito Dr. Del Mar, CA 92014 PC;/ 87-149 TELEPHONE (619) 438-1161 Dated March 23, 1987 Subject: Plan Check Expiration Our records indicate that you have not obtained your building permit for which you filed an application on the date shown above. The provisions of Section 304(c) of the Uniform Building Code state: Sec. 3@4(c) Expiration of Plan Check. Applications for which no permit is issued within 180 days following the date of application shall expire by limitation and plans submitted for checking may thereafter be returned to the applicant or destroyed by the Building Official. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant showing that circumstances beyond the control of the applicant have prevented action from being taken. In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan check fee. For your convenience, please check the appropriate box below indicating you1 intentions and return this letter to the address above. Project abandoned. I will pick up plans in 10 days. - Si,.. 0-atitre Date Prsjecc abandoned, plans may be destroyed. Signature Date xA”T< ..e...-xuc 190-iay tixe e:<ts~nsion rec.uested for the Collowi~g reassn: Sisnature Datz CERTIFICATION OF COMPLIANCE CITY OF CARLSBAD Plan Check No. DEVELOPXEXT PROCESSING SERVICES DIVISION 2075 LAS PALUS CARLSBAD, CA 92009 (619) 438-1161 This form shall be used to determine the amount of school fees for a project and to verify that the project applicant has complied with the school fee requirements. No building permits for the projects shall be issued until the certification is signed by the appropriate school district and returned to the City of Carlsbad Building Department. SCHOOL DISTRICT: Carlsbad Unified 801 Pine Avenue Carlsbad, CA 92008 (457-4985) - Sa? Marcos Unified 270 West San Marcos Blvd. San Marcos, CA 92069 (744-4776) - Encinitas Union Elementary San Dieguito Union High School 189 Union Street 625 North Vulcan Encinitas, CA 92024 (944-4306) Encinitas, CA 92024 (753-6491) Project Address: 360-7 /k LdNA ~5- RESIDENTIAL.: SQ. FT. of living area 5229 Number of dwelling units SQ. FT. of c0vere.d area SQ. FT. of garage area 9~d COMMERCIAL./ INDUSTRIAL.: SQ. FT. AREA Prepared By v yHL Date /O- 7 r7 ............................................. FEE CERTIFICATION 7f43cr LZ// 70 (To be completed by the School District) Applicant has complied with fee requirement under Govarment Code 53080 Project is subject to an existing fee agreement - Project is exempt from Government Code 53080 - Final Map approval and construction started before September 1, 1986. (other school fees paid) - Other &"' ;ased on L/ 65 sq. ft.@ /- Residential Fee Levied: $ J Comm/Indust F based on sq. Et.@ rict Official Title Date SB 201 fees are for residential. AB 2926 is caooed at Owner ' s Nane Elai 1 i ng Address - Hinsda1.e.. IL 6m Service Address: Assessor's Parcel No. Type of Building Connection Fee $600.00 Lateral Size: 4" Extra Footage: __ (pre-pd 200.00) - Lateral Fee Prorated Sewer "~ epresentative) of e District at the that extends from ucadia County Water t in the street (at is connected to r) from the appl i- r t.he construction, connection is made lateral shall be de in conformity T MUST BE INSPECTED BY THE APPLICANT. DISTRICT AT THE WILL BE CONSIDERED LATERAL OR COLLEC: INVALID AND WILL NOT BE ACKNOWLEDGED. The prorated sewer service fee is based upon the date the District estimates that additional fee or refund if service actually comnences on a different date. For service will begin and covers the balance of the fiscal year. There will be no succeeding fiscal years, the sewer service fee will be collected on the tax roll in the same manner as property taxes. The undersigned hereby agreesthat the above information given is correct and agrees to th2 conditions as stated. ,, _LCILAfi Accdunt No. DEVELOPMENT PROCESSING SERVICES DIVISION 2075 LAS PALMAS DRIVE CARLSBAD, CA 92009-4859 (619) 438-1161 MISCELLANEOUS FEE RECEIPT Appllcanl Plaasa Prlnt And Flll In Shaded Area Only ADDRESS CONTRACTOR’S ADDRESS MAILING CITY ZIP TEL. STATE LICENSE NO. BUSINESS LICENSE NO. SUBDIVISION LOT@) PLAN ID NO. $7- t+4 OOOB 03/23 0101 msc. 700.00 VALIDATION AREA ESTMATED VALUATION d6 I -> PLAN CHECK FEE 001-81000-00.8821 WITHIN 180 DAYS, PLAN CHECK FEES IF THE APPLICANT TAKES NO ACTION WILL BE FORFEITED. CHECK IF SUBMITTED w/ 2 ENERGY CALCS 0 2 1987 ENERGY CALCS FOR NON RESIDENTIAL BLDGS 0 2 STRUCTURAL CALCS & YILS REPORTS 2 SELF ADDRESSED ENVELOPES DATE GIVEN/ SENT TO APPLICANT DATE 4 COSTA LETTER i/GGHOOL FEE FORM P a E CORRECTIONS LIST CERTIFICATE OF OCCUPANCY White. File Yellow. Appllcant Pink. Finance Gold. Assessor n- il !. 'I RECORDING REQUESTED BY AND WHEN RECORDED MAIL TO: CITY OF CARLSBAD . 1 1200 Elm Avenue ) Carlsbad, California 92008 ) ) 1 Space above this line for Recorder's use Documentary transfer tax: $ No fee Signature-of declarant determining tax- firm name City of Carlsbad Parcel NO. ,?/5-+7/- ~6 HOLD HARMLESS AGREEMENT DRAIVAGE In consideration of the City's approval of a drainage plan (Plan No. PC 07-14? ) and/or improvement plans (Plan No. property described as ,&or 41 of ff 75-4 PEG? MAP 8302 (APNZI'5-4f/- /6 ), I (we) EL~TDL) I). Pnu4ER the owner(s) of said property promise to indemnify and to hold the City of Carlsbad and any of its agencies or employees harmless from liability for injuries to persons, or damage to or taking of property, directly or indirectly caused by the diversion of waters, the alteration of the normal flow of surface waters or drainage, or the concentration of surface waters or drainage from the drainage system or other improvements identified in the approved plans: or by the design, construction or maintenance of the drainage system or other improvements identified in the approved plans. - ) for development to occur on Approval of the plans by the City shall not constitute an assumption by the City of any responsibility for such damage or I -2- taking. City shall not be an insurer or surety for the design or construction of the improvements pursuant to the approved plans, nor shall any officer or employee thereof be liable or responsible for any accident, loss or damage happening or occuring during the construction work or improvements as specified in this agreement. It is further agreed that the above owner(s) will maintain all drainage systems to insure a free flow to a satisfactory point of discharge unless said systems are accepted as public facilities. It is further agr'eed that this agreement shall be binding on all heirs, successors or assigns having an interest in all or any part of the property described herein. IN WITNESS W EREOF, the under igned has executed this instrument this fd day of , 19a. SAFECO TITLE INSURANCE 8 STATE OF CALIFORNIA ,~ / COUNTY OF c. :, j .. 5 ; ~- SS. On this the . ,Ti '* m Notary Public in and for said County ard State, personally appeared -a 1 day of .~-. Cj,l L' :,,< ,' - 19_, before me the undersigned, a .. . ~. . 0 ? ,. ~ . - ! ... - m c ~ 1 I ..