Loading...
HomeMy WebLinkAbout2609 EL RASTRO LN; ; CB921095; PermitPermit No: CB921095 Project No: A9202253 Development No: 9910 10/29/92 0001 01 02 C-F'RiT 184-00 BUILDING PERMIT 10/29/92 13:11 Page 1 or I Job Address: 2609 EL RASTRO LN Suite: Permit Type: RESIDENTAL ADD/ALT Parcel No: 255-113-12-00 LoL#: Valuation: 14,952 Construction Type: VN Occupancy Group: R3 Reference#: Description: 168 SF KITCHEN NOOK Appl/Ownr : MATHIS, DENNIS 619 3351 VENADO STREET Status: ISSUED Applied; 10/13/92 Aor/Issue: 10/29/92 Validated By: DC 436-3435 CARLSBAD, CA 92093-' *** Fees Required **, 'rE Collected & Credits I I -: Adjustments: ,.. .70 - Totai,.00 Total Fees: 289. Total Pdyr':ri.t.: 105.00 -. - -. Bala nc:e i)u 184 .00 Fee description .1 - Units Fee/Unit Ext fee Data 41 ------------------------------._._;.____ - - --.------.-"------------------ Building Permit . / U 162.00 Plan Check . / U'c - 105.00 Strong Motion Fee . 2.00 BUILDING TOTAL 269.00 Enter Y' for Plumbing Isue I - I N Enter 'Y for Electric 1s;u F' * 0/ / 10.00 Y Enter !IU for Remodei > 1 :>i G / 10.00 Y INCORPORATED ELECTRICAL TOTAL '. 1 20.00 Enter '1' for Mechani'b / N APPROVAL INSP. _L211______ DATE _______ CLEARANCE CITY OF CARLSBAD' 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 CAt/7 PERMIT APPLICATION City of Carlsbad Building Department 2075 Las Patinas Dr.., Carlsbad, CA 92009 (619) 438-1161 S 1. PERMIT vi'i'i A - LI Commercial LI New Building LI Tenant Improvement B - 0 Industrial 0 New Building 0 Tenant Improvement C - 0 Residential 0 Apartment 0 Condo 0 Single Family Dwelling "Addition/A1teration Duplex 0 Demolition 0 Relocation 0 Mobile Home 0 Electrical 0 Plumbing Mechanical D Pool 0 Spa 0 Retaining Wall 0 Solar 0 Other__________ PLAN CHECK NO. (91_/o 75 ESTVAL PLAN CKDEPOSIT /0.5 VALID. BY 1) — DATE 9676 10/13/92 0001 01 02 C-PRMT 105 00 PROJECT INFORMATION - I FOR OFFICE USE ONLY ,%Uuress 2450cj El Ka f?0 L_L.Zneunuing or nuite INO. Nearest Cross Street LEGAL DESCRIPTION Lot No. Subdivision Name/Number Unit No. Phase No. 2..3 Rancho e( Poride..roq Tac+ 73-18 CHECK BELOW IF SUBMITFED: 02 Energy Calcs 02 Structural Catcs 02 Soils Report 0 1 Addressed Envelope ASSESSOR'S PARCEL Zcc - 113 —i 2_O 0 EXISTING USE PROPOSED USE DESCRIPTION OF WORK SQ. Ff. I'B # OF STORIES WN iAUr PERUN (it different trom applicant) NAME Oen s rno.*4 ADDRESS S I 'Jeir1c M CITY C4S tsbacl STATE C_pk ZIP CODEqoQq DAY TELEPHONE t) t.43(,— " t. 35 NAME ADDRESS CITY STATE ZIP CODE DAY TELEPHONE PROPERTY OWNER NAME __ ADDRESS Z60 E I a s#c, Lô vi £ CITY Cc*r( )bck St STATE (..P ZIP CODE 61 2CK) 9 DAY TELEPHONE L3L—,L4 3S (DNTRAC'IDR NAME y\4tt ADDRESS 3'S( \Je4A,4 4-. CITY (ç3 STATE (p.. ZIP CODE DAY TELEPHONE 5 STATE DC. # LICENSE CLASS CITY BUSINESS DC. # DESIGNER NAME ADDRESS CITY STATE ZIP CODE DAY TELEPHONE STATE DC. # WORKEHS WMPENSA11ON Workers' Compensation Declaration: I hereby affirm that I have a certificate of consent to sell-insure issued by the Director of Industrial Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. Q. INSURANCE COMPANY POLICY NO. EXPIRATION DATE Certificate 01 Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. SIGNATURE DATE OWNER-BUILDER DECLARATION Owner-Builder Declaration: I hereby affirm that I am exempt from the Contractor's License Law for the following reason: I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). X I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]). DATE - Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? DYES 0 N Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? DYES ONO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? DYES 0 N IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFl1R JULY 1, 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTE OF ThE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISI1UCf. WNSTRLJCTION LENDING AGENCY I hereby affirm that there is a construction lending agency tor the performance of the work for which this permit is issued (Sec 3097(1) Civil Code). LENDER'S NAME q / P, LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARlSBAD AGAINST ALL LIABILITIES, JUDGMENTS COSTS AND EXPENSES WIIICI-I MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMiT. OSHA: An OSHA permit is required for excavations over 5,0" deep and demolition or construction of structures over 3 stories in height. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code). APPLICANT'S SIGNATURE DATE: I C I1L CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB921095 FOR 01/13/93 INSPECTOR AREA TP DESCRIPTION: 168 SF KITCHEN NOOK PLANCK# CB921095 0CC GRP R3 TYPE: RAD /CONSTR. TYPE VN JOB ADDRESS: 2609 EL RASTRO LN STR: /FL: STE: APPLICANT: MATHIS, DENNIS PHONE: 619 436-43 CONTRACTOR: PHONE: OWNER: PHONE: REMARKS: MH/DENNIS/436-3435 SPECIAL INSTRUCT: TOTAL TIME: CD LVL DESCRIPTION 19 ST Final Structural 29 PL Final Plumbing 39 EL Final Electrical 49 ME Final Mechanical INSPECTOR ____________________ ACT COMMENTS INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP COMMENTS 120792 Interior Lath/Drywall AP TP 120792 Exterior Lath/Drywall AP TP 111792 Rough Combo AP TP 111792 Roof/Reroof AP TP 103092 Ftg/Foundation/Piers AP TP '7 lee L'— f-7<_ / öLAI1v4 —4 , IdOfd72 "7) 7--b , i,tYT12iA-' .'-(— PI :AN CRIM __________ JURISDICTION: CITY Of CARLSBAD PROJECT Ashio FLOORARFA: Plan check is limited to technical requirements èontained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances by the Planning Department, Engineering Department or other departments. Present California law mandates that residential construction comply with Title 24 and the following model codes: 1991 UBC (eff. 8/14/92) 1991 UPC (eff. 8/14/92) 1990 NEC (eff. 7/1/91) 1991 UMC (eff. 8/14/92) The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The circled items listed need clarification, modification or change. All items have to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303(c), 1991 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To smeed up the recheck process, note on this list (or a copy) where each correction item has been addressed i.e., plan sheet, specification. etc. Be sure to enclose the marked up list when you submit the revised plans. PLAN CORRECTION euocv CIT! OF CARLSBAD SINtK FANU.T AND DUPLEX INJ.LS Date plans received by jurisdiction: Date initial plan check completed: P'i Applicant contact person: (kMc /1d%5 Telephone: NOTE: PAGE NMOOM An NOT IN SJCE AS.PAGES RAVING NO ITEMS NEEDING LKX5flOIIS WK DVLRT). List No.. 2, Carlsbad Single Family Dwelling and Duplex With All Supplements. (1991 UBC) PLAM Please make all corrections on the original tracings and submit two new sets of prints, to: Dtpf Please make all corrections on the original tracings and submit -two new sets of prints, to: The jurisdiction's building department. Indicate on the Title Sheet of the plans, the name of the legal owner and name of person responsible for the preparation of the plans. Section 302(a)7. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). Plans, specifications and calculations shall be signed by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction. Specify expirati)n date of license. (California Business and Professions Code). Specify on the Title Sheet of the plans the gross floor area of each element of this project including dwelling, garage, carport, patio, deck and balcony. Section 302(d). Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1991 UBC, UMC and UPC and 1990 NEC. Submit fully dimensioned plot plan drawn to scale showing location, size, and use of all existing and proposed structures or the lot. Identify property lines and show lot dimensions and all easements. Show location of all cut or fill slopes. Show finish floor elevations and show elevations of adjacent finish grade. Show drainage patterns with minimum slopes. Section 302(d). Indicate distance from property lines to proposed construction. Section 302(d). Show on the title sheet all structures, pools, walls, etc. included under this application. Any portion of the project shown on the site plan that is not included with the building permit application filed should be clearly identified as "not included." Clearly show if the lower level is a basement or a story, based on the definitions in Sections 403 and 420. Plot the finish grade (as defined) on the elevations and dimension the distance to the floor above, for story determination. On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below or sticky back. REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec. 306 of the Uniform Building Code. ITEM REQ. IF REMARKS CHECKED SOILS COMPLIANCE PRIOR TO FOUNDATION INS?. STRUCTURAL CONCRETE OVER 2500 PSI PRESTRESSED STEEL FIELD WELDING HIGH STRENGTH BOLTS EXPANSION A}iQi0RS SPECIAL MASONRY SPRAYED ON FIRE PROOFING PILES/CAISSONS DESIGNER-SPECIFIED OTHER 13. Exterior walls closer than 3 feet to property lines shall be one-hour rated construction and have no openings. Table 5-A. 8/5/92 2 Exterior walls closer than 3 feet to a property line shall have 30 inch parapets when the floor area per floor exceeds 1,000 square feet. See Section 1710 for possible exception. Projections, including eaves, may not extend more than 12 inches into the 3 foot setback from the property line. Section 504(b). Eaves over required windows shall be not less than 30 inches from the side and rear property lines. Section 504(a). Projections, including eaves, shall be one-hour fire-resistive construction, heavy timber or of noncombustible material if they project into the 3' setback area from the property line. Section 1711. Plastic skylights shall not be installed within that portion of a roof located within a distance to property line where openings in exterior walls are prohibited or required to be rotected. Section 5207 (a) 7. L Show locations of permanently wired smoke detector with battery backup: I_f a. Inside each bedroom. b. Centrally located in corridor or area giving access to sleeping rooms. C. On each story. In the basement, if part of the dwelling unit. When sleeping rooms are upstairs, at the upper level in close proximity to the stair. In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway. NOTE: Detectors shall sound an alarm audible in all sleeping areas of the unit. Section 1210. When the valuation of a room addition or repair exceeds $1,000, or when sleeping rooms are created, smoke detectors shall be provided at existing bedrooms per item 19 above. Section 1210. Habitable rooms, other than kitchens, shall contain at least 70 square feet of flodr area. At least one room shall have not less than 120 square feet of floor area. Section 1207 (b). No habitable room, other than a kitchen, shall be less than 11 0" in any dimension. Section 1207 (c). Sleeping rooms shall have a window or exterior door for emergency exit. Sill height shall not exceed 44" above the floor. The window must have an openable area of at least 5.7 square feet with the minimum openable width 20" and the minimum openable height 24". Section 1204. Basements in dwelling units shall comly with the above (even if not designated as sleeping rooms). Section 1204. Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per Section1205 (b). Appears to be deficient in Openable window -area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet. In bathrooms, laundry rooms and similar rooms 1/20 of area is required and minimum is 1.5 sq. ft. Section 1205 (c). At least 1/2 of the coon wall must be open and have an opening not less than 25 sq. ft. nor one tenth of the floor area of the interior room if light and ventilation is being supplied from an adjacent room. Section 1205 (a). Required windows shall not open into a roofed porch unless the ceiling height is at least 7 feet, the longer side is at least 65% open, and the porch abuts a street, yard or court. Section 1205 (a). Provide mechanical ventilation capable of providing five air changes per hour in bathrooms, water closet compartments, laundry rooms and similar rooms if required openable windows are not provided. Section 1205 (c). Note that the discharge point for exhaust air will be at least 3 feet from any opening into the building. Section 1205(c). Ductless fans cannot be used in bathrooms if a tub or shower is present. Section 1205(c). Show that ceiling height for habitable rooms is a minimum of 716". Section 1207 (a). Show ceiling height for laundry rooms, hallways, corridors, and bathrooms is a minimum of 710". Section 1207 (a). Dimension on the plans 30" clear width for water closet compartments and 24" clearance in front of water closet. Section 511 (a). 5/22/92 3 49. Provide spiral stairway details, per Section 3306 (f): Minimum run is 7 1/2 inches measured at a point 12 inches from where the treads are the narrowest. Maximum rise is 9 1/2 inches. Maximum clear opening between risers is 6 inches. C. Minimum headroom is 6 feet 8 inches d. The tread must provide a clear walking area measuring at least 26 inches from the outer edge of the supporting column to the inner edge of the handrail. 50. Spiral stairways may not be used for required exits when the area served is greater than 400 sq. ft. Section 3306 (f). 51. Provide I.C.B.0. Research Report and number for metal stairway, or submit plans and calculations and approved fabricator registered with the building department or note that the stairway fabrication plans shall be submitted to and approved by the building official prior to installation. 52. Exterior stairways shall not project into the 3 foot setback from the property lines. Section 3306 (m). 53. The walls and soffits of the enclosed usable space under interior stairs shall be protected on the enclosed side as required for one-hour fire-resistive construction. Section 3306 (1). 54 Within units, show that corridors have a minimum width of 36 inches. Section 3305 (b). &ROOFIJG Specify roof slope. Roof slope is not adequate fox roof type specified. Table 32-B, D and E. Specify roof material and application. Chapter 32. Specify I.C.B.0. or. U.L. approval number for roof materials not covered in U.B.C., e.g., tile, etc. Section 107. Specify minimum 1/4 inch per foot roof slope for drainage or design to support accumulated water. Section 3207 (a) and Section 2305 (f). Show roof drains and overflows. Section 3207. Provide skylight details to show compliance with Sections 3401 and 5207 or provide I.C.B.O. approval number. Plastic skylights must be separated from each other by at least 4 feet, unless they are over the same room and their combined area does not exceed 100 square feet (or 200 square feet if the plastic is a "CCI" material). Section 507 (a) 6. Show attic ventilation. Minimum vent area is 1/150 of attic area or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above e.ave vents or cornice vents. Show required area and area provided. Section 3205 (c). Provide fireplace construction details or note construction to be per attached fireplace standard drawing. Chapter 37. Show anchored veneer support and connections attached to wood in Seismic Zones 3 and 4, comply with Section 3006 (d)l and Section 2515 (a). Show ties, #9 wire in horizontal joints, etc. Show height and construction details of all concrete and masonry walls. Chapters 24 and 26. Show floor and roof connections to masonry and concrete walls. Connection shall resist 200 pounds per lineal foot or the actual design load, whichever is greater. Cross grain tension or bending in wood ledgers is not permitted. Section 2310. Show a minimum 2" air space and flashing between planter and building walls. Section 2516 (c) 7. GARAGE AND CARS Garage requires one-hour fire protection on the garage side of walls and ceiling common to the dwelling. Table 5-B, Section 503 (d). All elements supporting floor aboye garage, including walls supporting floor joists, must have one-hour fire-resistive protection on the garage side. Section 503 (b) Show a self-closing door, either 1-3/8" solid co.re or a listed 20-minute assembly, for openings between garage and dwelling. Section 503 (d). 5/22/92 5 Garages are not permitted to open into a room used for sleeping purposes. Section 1104. An occupancy separation is not required between carport and residence, provided the carport is open on two or more sides and has no enclosed uses above. Section 503 (a) Exception 3. Show garage framing sections, size of header over garage opening, lateral cross bracing at plate line, method bracing garage front and holddowns if required. Chapter 23. NOTE: 1aximum shear panel height-to-width ratio is 3 1/2 to 1 for plywood. Table 25-I. Doors may open into the garage only if the floor or landing in the garage is not more than one inch lower than the door threshold. Section 3304 (i). Provide an 18" raised platform for any FAIJ, water heater, or other device in the garage which may generate a flame or spark. UMC Section 508, UPC Section 1310 (a). Per soils report, note on the plan the soils classification, whether or not the soil is expansive and the allowable bearing value. Section 2905 (c). The foundation plan does not comply with the soils report recommendations for this project. Please review the report and modify design, notes and details as required to show compliance: Provide notes on the foundation plan listing the soils report recommendation for foundations, slab and building pad preparation. The soils engineer recommended that he/she review the foundation excavations. Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that: The building pad was prepared in accordance with the soils report, The utility trenches have been properly backfilled and compacted, and The foundation excavations comply with the intent of the soils report". Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (when required by the soil report). Show height of all foundation walls. Chapter 23. Show height of retained earth on all foundation walls. Chapter 23. If cut or fill slopes exist, show distance from foundation to edge of cut or fill slopes and show steepness and heights of cuts and fills. Chapter 29. Note on plans that wood shall be 6" minimum above finish grade. Section 2907 (a). 6 Note on plans that surface water will drain away from building and show drainage pattern and key elevations. Section 2905 (f). 87. Dimension foundation per U.B.C. Table 29A: Floors Footing Supported* Stenwall Width Depth Thickness 1. 6" 12" 12" 6" 2 8" 15" 18" 7" 3 10" 18" 24" 8" Foundations may support a roof in addition to the loo *equal. only a roof is supported, use dation for one floor. 88. Show foundation sills to be pressure treated, or equal. Section 2516 (c) 3. 89. Show foundation bolt size and spacing. Section 2907 (f). 90. Specify size, I.C.B.0. number and manufacturer of power driven pins and expansion anchors. Show edge, end distances and spacing. Section 302 (d). 91. If required, show size, embedment and location of hold down anchors on foundation plan. Section 302 (d). 92. If hold downs are required, note on plan that hold down anchors must be tied in place prior to foundation inspection. Section 305 (e) 1. 93. Show adequate footings under all bearing walls and shear walls. Section 2907 (b). 5/22/92 6 Specify nail size and spacing for all shear walls, floor and roof diaphragms. Indicate required blocking. Maintain maximum diaphragm dimension ratios. [Tables 25 I, J, K and Section 4714 (d)]. Provide truss details and truss calculations for this project. Specify truss identification numbers on the plans. Show 1/2" minimum clearance between top plate of interior partitions and bottom chord of trusses. (To ensure loading will be as designed). 18. Provide roof framing plan and floor framing plan. Section 302 (d). Provide framing sections through Section 302 (d). Specify all header sizes for opening over 4' wide. Section 2517 (g) 5. Provide calculations for main vertical and horizontal framing members and post footings. Section 302 (b). Provide calculations for lateral loads, shear panels, shear transfer and related. Section 302 (b). In Seismic Zones 3 and 4, the allowable shear wall values for drywall in Table 47-I must be reduced 50 percent when considering earthquake loads. This does not apply to wind loads. Footnote 1. Show on the plans all structural requirements developed in the structural calculations. Section 302 (d). (See comments below or at end.) Columns and posts located on concrete or masonry floors or decks exposed to the weather or to water splash or in basements and which support permanent structures shall be supported by concrete piers or metal pedestals projecting above floors unless approved wood of natural resistance to decay or treated wood is used. Section 2516 (c) 4. Individual concrete or masonry piers shall project at least 8 inches above exposed ground unless the columns or posts which they support are of approved wood of natural resistance to \jdecay or treated wood is used. J Section 2516 (c) 4. Show location of attic access with a minimum size of 22"x3011, unless the maximum vertical headroom height in the attic is less than 30". Access must be provided to each separated attic area, shall be located in a hallway or other readily accessible location and 30" headroom clearance is required above the opening. Section 3205(a). Show location of attic access with minimum size 22" x 30". Section 3205. C29. Detail truss layout for 30" x 30" attic a ess, if required for equipment in the attic, and detail 30" x 30" clearance through truss webs. Specify plywood and/or particle board thickness, grade and panel span rating. Table 25-S. Show plywood sheathing over exposed eaves, or other weather exposed areas, is "bonded with exterior glue." Plywood used for exterior wall covering shall be the exterior type. Section 2516 (i), 2516(g)3. When roof pitch is less than 3:12, design ridge as a beam. Section 2517 (h). Ridges, hips, and valleys shall be at least one size larger than supported rafters. Section 2517 (h) 3. In open beam construction, provide strap ties across the beams at the ridge support. Section 2501 (b). If foundation cripple wall studs are less than 14" high, framing shall be solid blocking, or sheathed with plywood. Section 2517 (g) 4. Cripple wall studs exceeding 4 feet in height shall be 3 inch by 4 inch or 2 inches by 6 inches when supporting 2 stories. Section 2517 (g) 4. Note on the plans that "all weather-exposed surfaces shall have a weather-resistive barrier to protect the interior wall covering and that exterior openings shall be flashed in such a manner as to make them weatherproof". Section 1708.. MECHANICAL (UNIFO14 MARICALOWE) All heating, ventilating, and cooling systems and appliances shall comply with the Uniform Mechanical Code. 5/22/92 8 Show the size, location and type of all heating and cooling appliances or systems. Every dwelling unit shall be provided with heating facilities capable of maintaining a room temperature of 70 degrees F. at 3 feet above the floor in all habitable rooms. Show basis for compliance. UBC, Sec. 1212. Note on the plans that the FAU closet or alcove must be 12 inches wider than the furnace or furnaces being installed. UMC Section 704. - Show minimum 30" deep unobstructed working space in front of furnace. Section 505, UMC. Furnace shall not be installed in any bedroom, bathroom or in a closet or confined space with access only through such room unless specified as direct vent appliance, enclosed furnace or electric heating appliance. Section 704 UMC. Show source of combustion air to furnace, per Chapter 6, UMC. Show access to the attic containing equipment to be minimum 30 inches by 30 inches. The opening may be 22 inches by 30 inches if the equipment can be removed through such opening. Section 708 UMC. Note that passageway to the attic furnace shall be unobstructed and have continuous solid flooring not less than 24 inches wide, not more than 20 feet in length through the attic. Section 708 UMC. Show permanent electrical outlet and lighting fixture controlled by a switch for furnace located in attic or underfloor space. Section 708 & 709 UMC. Show details to comply with Section 709 for furnace under the floor, or Section 710 for roof or outside furnace. Show I.C.B.0. approval number for prefab fireplace. Show height of chimney above roof per I.C.B.O. approval or Table 37-B. Note on the plans that approved spark arrestors shall be installed on all chimneys. Section 3703(h) Provide dryer vent to outside. UMC, Section 1903. All wiring shall comply with the National Electrical Code. Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub- panels. If service is over 200 amps, submit single line diagram, panel schedule and load calculations. Show on the plan that receptacle outlets comply with 1990 NEC Art. 210-52(a), which reads as follows: In every kitchen, dining room, parlor, library, den, sunroom, bedroom, recreation room, or similar rooms or area of dwelling units, receptacle outlets shall be installed so that no point along the floor line in any wall space is more than 6 feet, measured horizontally, from an outlet in that space, including any wall space 2 feet or more in width and the wall space occupied by fixed panels in exterior walls, but excluding sliding panels in exterior walls. The wall space ..fforded by fixed room dividers, such as free-.s tanding bar-type counters, shall be included in the 6-foot measurement. Dwelling Unit Receptacle Outlets 210.52(a) I., .-••••.- -ll• .1. 1 SlicingPanels or Doors 150. Note on plan: Gas vents and non-combustible piping, in walls, passing through three floors or less shall be effectively draft stopped at each floor or ceiling. UBC, Section 1706 (c). 8/5/92 9 185. show on the Title Sheet on the plans, the informatiQn required by the attached Developmental Services Sheet 112383. All new residential buildings, including additions, require a soils report. Please submit two copies. Exception: If a room addition is limited to one story and 1000 sq. ft. in area, then a soils report is not required. Esgil Corporation will advise the City to place their soils notice stamp on the plans. Heavy timber framing, minimum 6" x 10" beams and minimum 8" x 8" post, for the structural beam and column supporting the fire separation between the garage and living area above, is acceptable if shown on the plans. (city policy). All structures require a Class B roof covering, except room additions. If a room addition covers all of the existing building (2nd story addition), then the above exception doesn't apply. City ordinande 9792 requires two parking spaces/unit with clear area of 201x20' i.e. no washing machines, etc. Show compliance. Only tank-type water closets that use an average of 1.6 gallons of water per flush or less, and urinals and associated flushometer valves, that use an average of 1 gallon of water per flush or less shall be installed in new construction. These provisions shall apply to existing buildings only when toilets are being replaced in existing bathrooms or installed in new bathrooms. MISCEU.ANXIS Please see additional corrections, or remarks, on the following page. To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please check. Yes No If you have any questions regarding these plan check items, please contact_________________ c'\d P&EQ.&ION If you have any questions regarding City Building permit procedures, please contact Caiter Darnell at the City of Carlsbad, 2075 Las Palmas Dr., telephone 619/1+38-1161. Thank you. Enclosures: A) 8/11/92 13 Jurisdiction CARLSEAD Prepared byt VALUATION AND PLAN CHECK FEE D Bldg. Dept. Q Esgil PLAN CHECK NO.—C?____________ BUILDING ADDRESS '1O _Gi_tro L APPLICANT/CONTACT PHONE NO. BUILDING OCCUPANCY DESIGNER PHONE_____________ TYPE OF CONSTRUCTION CONTRACTOR PHONE____________ BUILDING PORTION BUILDING ARack VALUATION MULTIPLIER VALUE • ___________ ________ _____________ I •H_____ Air Conditioninz Commercial - Residential 1 1 @ Res. or Comm. Fire SDrinklers • Total Value Buildirid Permit Fee $ Plan Check Fee 5 $ COM MENTS? SHEET OF_____ 12/87 City of IFO E Carlsbad BUILDING PLANCHECK CHECKLIST DATE:i5 (YT 2.. PLANCHECK NO.CB2H095 BUILDING ADDRESS: 2€39 EL 1!i0ST12.O LN PROJECT DESCRIPTION: 1, All ASSESSOR's PARCEL NUMBER: 255 /13-12. EST. VALUE___________ ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. DENIAL Please see the attached report of deficiencies marked with 9 Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. 13y:Sf1EbELL Date: iS ccrqz By:_ Date:_________ ATTACHMENTS O Dedication Application O Dedication Checklist O Improvement Application O Improvement Checklist O Future Improvement Agreement NAME: ADDRESS: CONTACT PERSON PHONE: P:\docs\chklst\bp0001.frm REV 6/5/92 2075 Las Palmas Dr. • Carlsbad, CA 92009-1576. (619) 438-1161 • FAX (619) 438-0894 BUILDING PLANCHECK CHECKLIST SITE PLAN 1s) 2nd,/ 3rd' El El 1. Pr9vide a fully dimensioned site plan drawn to scale. Show: North Arrow D. Property Lines Easements Existing & Proposed Structures E. Easements Existing Street Improvements F. Right-of-Way Width & Adjacent Streets gj. 0 0 2. Show on site plan: Z::A:~r inag ) C. Existing Topography B. Et9&Proposed Slopes Ei2( 0 0 3. Show on a section drawing or include a note stating that there is a minimum of 6" difference between the finished floor and the finished grade elevation adjacent to the structure. J. 0 0 4--'Include note: "Surface water to be directed away from the building foundation at a 2% ( gradient for no less than 5' or 2/3 the distance to the property line (whichever is less)." \ [Per 1985 UBC 2907(d)51. On graded sites, the top of any exterior foundation shall extend above the elevation of the Street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12 inches plus two percent" (per 1990 UBC 2907(d)5.). /E3 0 5. Include on title sheet Site address Assessor's Parcel Number Legal Description For commercial/industrial buildings and tenant improvement projects, include: Total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. - EXISTING PERMIT NUMBER DESCRIPTION P:\docs\chk1st\bp0001.frm Page 1 of 4 REV 6/5/92 BUILDING PLANCHECK CHECKLIST F// DISCRETIONARY APPROVAL COMPLIANCE 1 sW 2nd' 3rd-,/ El 0 0 6. Project does not comply with the following Engineering Conditions of approval for Project No. Conditions were complied with by: Date:__________________ DEDICATION REQUIREMENTS O 0 0 7. Dedication for all Street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $______________ -pursuant to Code Section 18.40.030. Dedication required as follows: Attached please find an application form and submittal checklist for the dedication process. Provide the completed application form and the requirements on the checklist at the time of resubmittal. Dedication completed by Date:___________ IMPROVEMENT REQUIREMENTS 0 El El 8a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ -pursuant to Code Section 18.40.040. Public improvements required as follows: Please have a registered Civil Engineer prepare appropriate improvement plans and submit them together with the requirements on the attached checklist for a separate plancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. Attached please find an application form and submittal checklist for the public improvements requirements. Provide the completed application form and the requirements on the checklist at the time of resubmittal. Improvement Plans signed by: Date: P:\docs\chklst\bp000l.frm Page 2 of 4 REV 6/5/92 BUILDING PLANCHECK CHECKLIST 1 SW 2nd' 3rdv' 0 0 0 8b. Construction of the public improvements may be deferred pursuant to code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $_____________________ so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit. Future public improvements required as follows:_______________________________ O 0 0 8c. Enclosed please find your Future Improvement Agreement. Please return signed and notarized Agreement to the Engineering Department. Future Improvement Agreement completed by:________________________________ Date:__________________ 0 0 8d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the Cliv Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11 .06.030 of the Municipal Code. 0 0 0 9a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). O 0 0 9b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be Submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: d 0 .0 9c. No Grading Permit required. BUILDING PLANCHECK CHECKLIST P:\docs\chk1st\bp0001.1rm Page 3 of 4 REV 6/5/92 N/A MISCELLANEOUS PERMITS 1 SW 2nd/ 3rd/ 0 0 D 10. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: Street improvements, trees, driveways. A separate Right-of-Way permit issued by the Engineering Department is required for the following: Please complete attached Right-of-Way application form and return to the Engineering Department together with the requirements on the attached Right-of-Way checklist, at the time of resubmittal. O 0 0 11. A SEWER PERMIT is required concurrent with the building permit issuance. The fee is noted in the fees section on the following page. O 0 0 12. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial Waste Permit Application Form and submit for City approval prior to issuance of a Permit. Industrial waste permit accepted by: Date: P:\docs\chk1st\bp0001.frm Page 4 of 4 REV 6/5/92 CALCULATIONS WORKSHEET EDU CALCULATIONS: EDU's: ADT CALCULATIONS: ADT's: FEES REQUIRED: WITHIN CFD: 0 YES (NO BRIDGE & THOROUGHFARE FEE, REDUCED TRAFFIC IMPACT FEE) DNO 0 1. PARK-IN-LIEU FEE PARK AREA: FEE/UNIT:_________ 0 2.TRAFFIC IMPACT FEE ADT's: FEE/ADT: BRIDGE AND THOROUGHFARE FEE ADT's: FEE/ADT: FACILITIES MANAGEMENT FEE ZONE:___________ o 5. PUBLIC FACILITIES FEE 0 6. SEWER FEES PERMIT No. EDU's: BENEFIT AREA: FEE/EDU:_________ FEE/EDU: FEE: 0 7. SEWER LATERAL REQUIRED (2,500 DEPOSIT) P:\docs\chklsl\bpOOOl.frm REV 6/5/92 PLANNING QEQQIST Plan Check No. - /95Address G 0? E/ ZJ 7'YtJ / Planner DAVID RICK Phone 438-1161 ext. 4328 (Name) APN:- 2Ty -/13 -,2 Type of Project and Use R?'ç. 4tihi 7ni Pri1ri.c Miniap,mnr 7t-vi. i 7 Legend LJ Item Complete -..' (J2 Item Incomplete - Needs your action 1, 2, 3 Number in circle indicates plancheck number where deficiency was - identified 0 Environmental Review Required: YES NO E DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval 0 Discretionary Action Required: YES - NO APPROVAL/RESO. NO. DATE: PROJECT NO.'_________ OTHER RELATED CASES: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval California Coastal Commission Permit Required: YES NO DATE OF APPROVAL: San Diego Coast District, 3111 Camino Del Rio North Suite 200, San Diego, CA. 92108-1725 (619) 5218036 Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval Landscape Plan Required: YES NO See attached sübmittál requirements for landscape plans Site Plan: Provide a fully dimensioned site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width and - dimensioned setbacks. 2'D 0 2. Show on Site Plan: Finish floor elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes and driveway. "D C3 Provide legal description of property. CJ-d'iE] 4. Provide assessor's parcel number. Zoning 0 1. Setbacks: Front: Required 2— C' Shown 2 C) / Int. Side: Required 3 / Shown -7,57 Street Side: Required A1'- Shown A..A- - Rear: Required ' 2 , ' Shown (9 / Lot coverage: Required LLY Shown '- Height: Required 3 " Shown ? / rc 3 0 4. Parking: Spaces Required 2 c72shown jivs- Guest Spaces Required _____ Shown 0 0 0 Additional Comments OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER____________ DATE PLNCK.FRM